Bone & Joint Open
Vol. 3, Issue 10 | Pages 795 - 803
12 Oct 2022
Liechti EF Attinger MC Hecker A Kuonen K Michel A Klenke FM

Aims. Traditionally, total hip arthroplasty (THA) templating has been performed on anteroposterior (AP) pelvis radiographs. Recently, additional AP hip radiographs have been recommended for accurate measurement of the femoral offset (FO). To verify this claim, this study aimed to establish quantitative data of the measurement error of the FO in relation to leg position and X-ray source position using a newly developed geometric model and clinical data. Methods. We analyzed the FOs measured on AP hip and pelvis radiographs in a prospective consecutive series of 55 patients undergoing unilateral primary THA for hip osteoarthritis. To determine sample size, a power analysis was performed. Patients’ position and X-ray beam setting followed a standardized protocol to achieve reproducible projections. All images were calibrated with the KingMark calibration system. In addition, a geometric model was created to evaluate both the effects of leg position (rotation and abduction/adduction) and the effects of X-ray source position on FO measurement. Results. The mean FOs measured on AP hip and pelvis radiographs were 38.0 mm (SD 6.4) and 36.6 mm (SD 6.3) (p < 0.001), respectively. Radiological view had a smaller effect on FO measurement than inaccurate leg positioning. The model showed a non-linear relationship between projected FO and femoral neck orientation; at 30° external neck rotation (with reference to the detector plane), a true FO of 40 mm was underestimated by up to 20% (7.8 mm). With a neutral to mild external neck rotation (≤ 15°), the underestimation was less than 7% (2.7 mm). The effect of abduction and adduction was negligible. Conclusion. For routine THA templating, an AP pelvis radiograph remains the gold standard. Only patients with femoral neck malrotation > 15° on the AP pelvis view, e.g. due to external rotation contracture, should receive further imaging. Options include an additional AP hip view with elevation of the entire affected hip to align the femoral neck more parallel to the detector, or a CT scan in more severe cases. Cite this article: Bone Jt Open 2022;3(10):795–803


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 233 - 233
1 Sep 2012
Thomson S Napier R Thompson N
Full Access

Introduction. Dislocation is one of the most common complications following total hip arthroplasty. The literature suggests a frequency of 1–3% for primary total hip replacement (THR) and 7–10% for revision procedures. No definitive treatment algorithm exists for their management, with some surgeons attempting to constrain hip motion with casting or bracing initially. The evidence for this practice is limited. The purpose of this study was to determine the current practice for managing THR dislocation within our unit, and to determine the effectiveness of abduction bracing. Method. A retrospective case-note analysis was performed on all patients admitted with a dislocated THR between 01/01/08 and 31/12/10. Patients were categorised into three groups: first time dislocators, recurrent dislocators, or dislocation occurring following revision surgery. The following data was collected; time from original surgery, closed or open reduction, surgical approach, prescription of abduction brace post-operatively, and the number of subsequent dislocations. Any patients who underwent open reduction were excluded from the study. Results. A total of 45 patients were included in the study. Of the first time dislocators, 75% treated with abduction brace re-dislocated, and 26% of patients treated without bracing re-dislocated. In the recurrent group 63% had been braced after their initial dislocation. Conclusion. Based on this study the benefit of abduction braces is limited and patient compliance tends to be poor. The cost of these appliances is significant (£450/£525) and patients typically have a prolonged hospital stay for ordering and application. Our unit has subsequently discontinued the use of such braces. Goals to reducing THR dislocation remain; meticulous preoperative planning and patient selection, accurate component positioning with intraoperative stability testing, good soft tissue repair, and early patient education


Bone & Joint Research
Vol. 13, Issue 9 | Pages 485 - 496
13 Sep 2024
Postolka B Taylor WR Fucentese SF List R Schütz P

Aims. This study aimed to analyze kinematics and kinetics of the tibiofemoral joint in healthy subjects with valgus, neutral, and varus limb alignment throughout multiple gait activities using dynamic videofluoroscopy. Methods. Five subjects with valgus, 12 with neutral, and ten with varus limb alignment were assessed during multiple complete cycles of level walking, downhill walking, and stair descent using a combination of dynamic videofluoroscopy, ground reaction force plates, and optical motion capture. Following 2D/3D registration, tibiofemoral kinematics and kinetics were compared between the three limb alignment groups. Results. No significant differences for the rotational or translational patterns between the different limb alignment groups were found for level walking, downhill walking, or stair descent. Neutral and varus aligned subjects showed a mean centre of rotation located on the medial condyle for the loaded stance phase of all three gait activities. Valgus alignment, however, resulted in a centrally located centre of rotation for level and downhill walking, but a more medial centre of rotation during stair descent. Knee adduction/abduction moments were significantly influenced by limb alignment, with an increasing knee adduction moment from valgus through neutral to varus. Conclusion. Limb alignment was not reflected in the condylar kinematics, but did significantly affect the knee adduction moment. Variations in frontal plane limb alignment seem not to be a main modulator of condylar kinematics. The presented data provide insights into the influence of anatomical parameters on tibiofemoral kinematics and kinetics towards enhancing clinical decision-making and surgical restoration of natural knee joint motion and loading. Cite this article: Bone Joint Res 2024;13(9):485–496


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1067 - 1074
1 Dec 2021
El-Bakoury A Khedr W Williams M Eid Y Hammad AS

Aims. After failed acetabular fractures, total hip arthroplasty (THA) is a challenging procedure and considered the gold standard treatment. The complexity of the procedure depends on the fracture pattern and the initial fracture management. This study’s primary aim was to evaluate patient-reported outcome measures (PROMs) for patients who underwent delayed uncemented acetabular THA after acetabular fractures. The secondary aims were to assess the radiological outcome and the incidence of the associated complications in those patients. Methods. A total of 40 patients underwent cementless acetabular THA following failed treatment of acetabular fractures. The postoperative clinical and radiological outcomes were evaluated for all the cohort. Results. The median (interquartile range (IQR)) Oxford Hip Score (OHS) improved significantly from 9.5 (7 to 11.5), (95% confidence interval (CI) (8 to 10.6)) to 40 (39 to 44), (95% CI (40 to 43)) postoperatively at the latest follow-up (p < 0.001). It was worth noting that the initial acetabular fracture type (simple vs complex), previous acetabular treatment (ORIF vs conservative), fracture union, and restoration of anatomical centre of rotation (COR) did not affect the final OHS. The reconstructed centre of rotation (COR) was restored in 29 (72.5%) patients. The mean abduction angle in whom acetabular fractures were managed conservatively was statistically significantly higher than the surgically treated patients 42.6° (SD 7.4) vs 38° (SD 5.6)) (p = 0.032). We did not have any case of acetabular or femoral loosening at the time of the last follow-up. We had two patients with successful two-stage revision for infection with overall eight-year survival rate was 95.2% (95% CI 86.6% to 100%) with revision for any reason at a median (IQR) duration of follow-up 50 months (16 to 87) months following THA. Conclusion. Delayed cementless acetabular THA in patients with previous failed acetabular fracture treatments produces good clinical outcomes (PROMS) with excellent survivorship, despite the technically demanding nature of the procedure. The initial fracture treatment does not influence the outcome of delayed THA. In selected cases of acetabular fractures (either nondisplaced or with secondary congruency), the initial nonoperative treatment neither resulted in large acetabular defects nor required additional acetabular reconstruction at the time of THA. Cite this article: Bone Jt Open 2021;2(12):1067–1074


Bone & Joint Open
Vol. 4, Issue 7 | Pages 496 - 506
5 Jul 2023
Theunissen WWES Van der Steen MC Van Veen MR Van Douveren FQMP Witlox MA Tolk JJ

Aims

The aim of this study was to identify the information topics that should be addressed according to the parents of children with developmental dysplasia of the hip (DDH) in the diagnostic and treatment phase during the first year of life. Second, we explored parental recommendations to further optimize the information provision in DDH care.

Methods

A qualitative study with semi-structured interviews was conducted between September and December 2020. A purposive sample of parents of children aged younger than one year, who were treated for DDH with a Pavlik harness, were interviewed until data saturation was achieved. A total of 20 interviews with 22 parents were conducted. Interviews were audio recorded, transcribed verbatim, independently reviewed, and coded into categories and themes.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 32 - 32
19 Aug 2024
Caplash G Caplash Y Copson D Thewlis D Ehrlich A Solomon LB Ramasamy B
Full Access

Few surgical techniques to reconstruct the abductor mechanism of the hip have been reported, with outcomes reported only from case reports and small case series from the centres that described the techniques. As in many of our revision THA patients the gluteus maximus was affected by previous repeat posterior approaches, we opted to reconstruct the abductor mechanism using a vastus lateralis to gluteus medius transfer. We report the results of such reconstructions in seven patients, mean age 66 (range, 53–77), five females, presenting with severe abductor deficiency (MRC grade 1–2). Five patients had previous revision THA, two with a proximal femoral replacement, one patient had a primary THA after a failed malunited trochanteric fracture, and one patient had a native hip with idiopathic fatty infiltration of glutei of >90%. All patients had instrumented gait analysis, and surface electromyography (EMG) of the glutei, TFL, and vastus muscles simultaneously before surgery and at each post-op follow-up. Postoperatively, patients were allowed to weight bear as tolerated and were requested to wear an abduction brace for the first six weeks after surgery to protect the transfer. All patients improved after surgery and reached an abductor power of 3 or more. All patients walked without support six months after surgery and were satisfied with the result. Abductor function continued to improve beyond one year of follow-up, and some patients reached an abductor power of 5. EMG demonstrated that the transferred vastus lateralis started firing synchronously with gluteus medius after three months post-surgery, suggesting adaptation to its new function. No knee extension weakness was recorded. One patient complained of lateral thigh numbness and was dissatisfied with the cosmetic look of her thigh after surgery. Our preliminary results are encouraging and comparable with those achieved by the originators of the technique


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 17 - 17
1 Dec 2022
Kowalski E Dervin G Lamontagne M
Full Access

One in five patients remain unsatisfied due to ongoing pain and impaired mobility following total knee arthroplasty (TKA). It is important if surgeons can pre-operatively identify which patients may be at risk for poor outcomes after TKA. The purpose of this study was to determine if there is an association between pre-operative measures and post-operative outcomes in patients who underwent TKA. This study included 28 patients (female = 12 / male = 16, age = 63.6 ± 6.9, BMI = 29.9 ± 7.4 kg/m2) with knee osteoarthritis who were scheduled to undergo TKA. All surgeries were performed by the same surgeon (GD), and a subvastus approach was performed for all patients. Patients visited the gait lab within one-month of surgery and 12 months following surgery. At the gait lab, patients completed the knee injury and osteoarthritis outcome score (KOOS), a timed up and go (TUG), and walking task. Variables of interest included the five KOOS sub-scores (symptoms, pain, activities of daily living, sport & recreation, and quality of life), completion time for the TUG, walking speed, and peak knee biomechanics variables (flexion angle, abduction moment, power absorption). A Pearson's product-moment correlation was run to assess the relationship between pre-operative measures and post-operative outcomes in the TKA patients. Preliminary analyses showed the relationship to be linear with all variables normally distributed, as assessed by Shapiro-Wilk's test (p > .05), and there were no outliers. There were no statistically significant correlations between any of the pre-operative KOOS sub-scores and any of the post-operative biomechanical outcomes. Pre-operative TUG time had a statistically significant, moderate positive correlation with post-operative peak knee abduction moments [r(14) = .597, p < .001] and peak knee power absorption [r(14) = .498, p = .007], with pre-operative TUG time explaining 36% of the variability in peak knee abduction moment and 25% of the variability in peak knee power absorption. Pre-operative walking speed had a statistically significant, moderate negative correlation with post-operative peak knee abduction moments [r(14) = -.558, p = .002] and peak knee power absorption [r(14) = -.548, p = .003], with pre-operative walking speed explaining 31% of the variability in peak knee abduction moment and 30% of the variability in peak knee power absorption. Patient reported outcome measures (PROMs), such as the KOOS, do indicate the TKA is generally successful at relieving pain and show an overall improvement. However, their pre-operative values do not correlate with any biomechanical indicators of post-operative success, such as peak knee abduction moment and knee power. Shorter pre-operative TUG times and faster pre-operative walking speeds were correlated with improved post-operative biomechanical outcomes. These are simple tasks surgeons can implement into their clinics to evaluate their patients. Future research should expand these findings to a larger sample size and to determine if other factors, such as surgical approach or implant design, improves patient outcomes


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 57 - 57
1 Nov 2022
Prem R West B Jenner E Bolton L Deshmukh S
Full Access

Abstract. Aim. This study aims to Inter and intra observer reliability compare, use of a standard goniometer (SG) to measure intermetacarpal angle (degrees) vs use of a new technique of using a digital vernier calliper (DVC) (mm) to measure the distance between the first and second metacarpal head. Method. Maximal active abduction and extension of both thumbs was measured in 20 healthy volunteers on two occasions at least one week apart by two assessors. Results. The inter and intra-observer agreement was higher & the variance of the data was lower using the DVC with the new technique than the SG for both thumb abduction and extension. Additionally, the correlation between measurement of extension and abduction was higher using the DVC than the SG. Conclusion. Whilst both tools provide acceptable intra and inter-observer agreement, the new technique using a DVC is consistently better and more reliable than a SG in measuring thumb abduction and extension. The study also supports our hypothesis that the thumb rotates around the second metacarpal head with a consistent radius


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 91 - 91
1 Dec 2022
Rizkallah M Aoude A Turcotte R
Full Access

Resection of the proximal femur raises several challenges to the orthopedic oncology surgeon. Among these is the re-establishment of the abductor mechanism that might impacts on hip function. Extent of tumor resection and surgeons’ preferences dictate the reconstruction method of the abductors. While some surgeons advocate the necessity of greater trochanter (GT) preservation whenever possible, others attempt direct soft tissues reattachment to the prosthesis. Sparse data in the literature evaluated the outcomes of greater trochanter fixation to the proximal femur megaprosthesis. This is a retrospective monocentric study. All patients who received a proximal femoral replacement after tumor resection between 2005 and 2021 with a minimum follow-up of three months were included. Patients were divided into two groups: (1) those with preserved GT reattached to the megaprosthesis and (2) those with direct or indirect (tenodesis to fascia lata) abductor muscles reattachment. Both groups were compared for surgical outcomes (dislocation and revision rates) and functional outcomes (Trendelenburg gait, use of walking-assistive device and abductor muscle strength). Additionally patients in group 1 were subdivided into patients who received GT reinsertion using a grip and cables and those who got direct GT reinsertion using suture materials and studied for GT displacement at three, six and 12 months. Time to cable rupture was recorded and analyzed through a survival analysis. Fifty-six patients were included in this study with a mean follow-up of 45 months (3-180). There were 23 patients with reinserted GT (group 1) and 33 patients with soft tissue repair (group 2). Revision rate was comparable between both groups(p=0.23); however, there were more dislocations in group 2 (0/23 vs 6/33; p=0.037). Functional outcomes were comparable, with 78% of patients in group 1 (18/23) and 73% of patients in group 2 (24/33) that displayed a Trendelenburg gait (p=0.76). In group 1, 70% (16/23) used walking aids compared to 79% of group 2 (27/33) (p=0.34). Mean abductor strength reached 2.7 in group 1 compared to 2.3 in group 2 (p=0.06). In group 1, 16 of the 23 patients had GT reinsertion with grip and cables. Median survival of cables for these 16 patients reached 13 months in our series. GT displacement reached a mean of two mm, three mm, and 11 mm respectively at three, six and 12 months of follow-up in patients with grip and cables compared to 12 mm, 24 mm and 26 mm respectively at the same follow-up intervals in patients with GT stand-alone suture reinsertion(p<0.05). Although GT preservation and reinsertion did not improve functional outcomes after proximal femur resection and reconstruction with a megaprosthesis, it was significantly associated with lower dislocation rate despite frequent cable failure and secondary GT migration. No cable or grip revision or removal was recorded. Significantly less displacement was observed in patients for whom GT reattachment used plate and cables rather than sutures only. Therefore we suggest that GT should be preserved and reattached whenever possible and that GT reinsertion benefits from strong materials such as grip and cables


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 79 - 79
1 Dec 2022
Langohr GD Mahaffy M Athwal G Johnson JA
Full Access

Patients receiving reverse total shoulder arthroplasty (RTSA) often have osseous erosions because of glenohumeral arthritis, leading to increased surgical complexity. Glenoid implant fixation is a primary predictor of the success of RTSA and affects micromotion at the bone-implant interface. Augmented implants which incorporate specific geometry to address superior erosion are currently available, but the clinical outcomes of these implants are still considered short-term. The objective of this study was to investigate micromotion at the glenoid-baseplate interface for a standard, 3 mm and 6 mm lateralized baseplates, half-wedge, and full-wedge baseplates. It was hypothesized that the mechanism of load distribution from the baseplate to the glenoid will differ between implants, and these varying mechanisms will affect overall baseplate micromotion. Clinical CT scans of seven shoulders (mean age 69 years, 10°-19° glenoid inclinations) that were classified as having E2-type glenoid erosions were used to generate 3D scapula models using MIMICS image processing software (Materialise, Belgium) with a 0.75 mm mesh size. Each scapula was then repeatedly virtually reconstructed with the five implant types (standard,3mm,6mm lateralized, and half/full wedge; Fig.1) positioned in neutral version and inclination with full backside contact. The reconstructed scapulae were then imported into ABAQUS (SIMULIA, U.S.) finite element software and loads were applied simulating 15°,30°,45°,60°,75°, and 90° of abduction based on published instrumented in-vivo implant data. The micromotion normal and tangential to the bone surface, and effective load transfer area were recorded for each implant and abduction angle. A repeated measures ANOVA was used to perform statistical analysis. Maximum normal micromotion was found to be significantly less when using the standard baseplate (5±4 μm), as opposed to the full-wedge (16±7 μm, p=0.004), 3 mm lateralized (10±6 μm, p=0.017), and 6 mm lateralized (16±8 μm, p=0.007) baseplates (Fig.2). The half-wedge baseplate (11±7 μm) also produced significantly less micromotion than the full-wedge (p=0.003), and the 3 mm lateralized produced less micromotion than the full wedge (p=0.026) and 6 mm lateralized (p=0.003). Similarly, maximum tangential micromotion was found to be significantly less when using the standard baseplate (7±4 μm), as opposed to the half-wedge (12±5 μm, p=0.014), 3 mm lateralized (10±5 μm, p=0.003), and 6 mm lateralized (13±6 μm, p=0.003) baseplates (Fig.2). The full wedge (11±3 μm), half-wedge, and 3 mm lateralized baseplate also produced significantly less micromotion than the 6 mm lateralized (p=0.027, p=012, p=0.02, respectively). Both normal and tangential micromotion were highest at the 30° and 45° abduction angles (Fig.2). The effective load transfer area (ELTA) was lowest for the full wedge, followed by the half wedge, 6mm, 3mm, and standard baseplates (Fig.3) and increased with abduction angle. Glenoid baseplates with reduced lateralization and flat backside geometries resulted in the best outcomes with regards to normal and tangential micromotion. However, these types of implants are not always feasible due to the required amount of bone removal, and medialization of the bone-implant interface. Future work should study the acceptable levels of bone removal for patients with E-type glenoid erosion and the corresponding best implant selections for such cases. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 24 - 24
23 Jun 2023
Byrd JWT Jones KS Bardowski EA
Full Access

Partial thickness abductor tendon tears are a significant source of recalcitrant laterally based hip pain. For those that fail conservative treatment, the results of endoscopic repair are highly successful with minimal morbidity. The principal burden is the protracted rehabilitation that is necessary as part of the recovery process. There is a wide gap between failed conservative treatment and successful surgical repair. It is hypothesized that a non-repair surgical strategy, such as a bioinducitve patch, could significantly reduce the burden associated recovery from a formal repair. Thus, the purpose of this study is to report the preliminary results of this treatment strategy. Symptomatic partial thickness abductor tendon tears are treated conservatively, including activity modification, supervised physical therapy and ultrasound guided corticosteroid injections. Beginning in January 2022, patients undergoing hip arthroscopy for intraarticular pathology who also had persistently symptomatic partial thickness abductor tendon tears, were treated with adjunct placement of a bioinducitve (Regeneten) patch over the tendon lesion from the peritrochanteric space. The postop rehab protocol is dictated by the intraarticular procedure performed. All patients are prospectively assessed with a modified Harris Hip Score (mHHS) and iHOT and the tendon healing response examined by ultrasound. Early outcomes will be presented on nine consecutive cases. Conclusions - Will be summarized based on the preliminary outcomes to be reported


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 2 - 2
16 May 2024
Schwagten K
Full Access

Background. Iatrogenic hallux varus is a rare complication after hallux valgus surgery. Operative treatment comprises a wide variety of techniques, of which the reversed transfer of the abductor hallucis tendon is the most recent described technique. Methods. This paper will present the long-term clinical results of the reversed transfer of the abductor hallucis longus. Therefore, we performed a prospective clinical observational study on 16 female patients. Our hypothesis is that the tendon transfer will persist in a good alignment and patient satisfaction on long term. There is a 100% follow-up rate with a range from 10 to 101 months. Patients were subjected to a clinical examination, three questionnaires and their general satisfaction. Results. Out of 16 patients, at time of follow-up, we found a positive correlation between the subjective outcome score and alignment (r = 0.59), and between the general satisfaction and alignment (r = 0.77). Based on the general satisfaction we achieved a success satisfaction rate of 69% (11 patients). The other 31% (5 patients) patient group was only satisfied with major reservations or not satisfied at all. The two most invalidating complications were a coronal or sagittal malalignment or the combination of both. Conclusion. Our results suggest that the reverse abductor hallucis tendon transfer is a good technique to treat a supple iatrogenic hallux varus with an observed success satisfaction rate of 69% at a mean follow-up time of 48 (range 10–101) months. However, patients should be informed that on the long-term loss of correction is possible


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 77 - 77
7 Nov 2023
Dey R Nortje M du Toit F Grobler G Dower B
Full Access

Hip abductor tears(AT) have long been under-recognized, under-reported and under-treated. There is a paucity of data on the prevalence, morphology and associated factors. Patients with “rotator cuff tears of the hip” that are recognized and repaired during total hip arthroplasty(THA) report comparable outcomes to patients with intact abductor tendons at THA. The study was a retrospective review of 997 primary THA done by a single surgeon from 2012–2022. Incidental findings of AT identified during the anterolateral approach to the hip were documented with patient name, gender, age and diagnosis. The extent and size of the tears of the Gluteus medius and Minimus were recorded. Xrays and MRI's were collected for the 140 patients who had AT and matched 1:1 with respect to age and gender against 140 patients that had documented good muscle quality and integrity. Radiographic measurements (Neck shaft angle, inter-teardrop distance, Pelvis width, trochanteric width and irregularities, bodyweight moment arm and abductor moment arm) were compared between the 2 groups in an effort to determine if any radiographic feature would predict AT. The prevalence of AT were 14%. Females had statistically more tears than males(18vs10%), while patients over the age of 70y had statistically more tears overall(19,7vs10,4%), but also more Gluteus Medius tears specifically(13,9vs5,3%). Radiographic measurements did not statistically differ between the tear and control group, except for the presence of trochanteric irregularities. MRI's showed that 50% of AT were missed and subsequently identified during surgery. Abductor tears are still underrecognized and undertreated during THA which can results in inferior outcomes. The surgeon should have an high index of suspicion in elderly females with trochanteric irregularities and although an MRI for every patient won't be feasible, one should always be prepared and equipped to repair the abductor tendons during THA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 26 - 26
11 Apr 2023
Kowalski E Pelegrinelli A Ryan N Dervin G Lamontagne M
Full Access

This study examined pre-operative measures to predict post-operative biomechanical outcomes in total knee arthroplasty (TKA) patients. Twenty-eight patients (female=12/male=16, age=63.6±6.9, BMI=29.9±7.4 kg/m2) with knee osteoarthritis scheduled to undergo TKA were included. All surgeries were performed by the same surgeon (GD) with a subvastus approach. Patients visited the gait lab within one-month prior to surgery and 12 months following surgery. At the gait lab, patients completed the knee injury and osteoarthritis outcome score (KOOS), a timed up and go (TUG), maximum knee flexion and extension strength evaluation, and a walking task. Variables of interest included the five KOOS sub-scores, TUG time, maximum knee flexion and extension strength normalized to body weight, walking speed, and peak knee biomechanics variables (flexion angle, abduction moment, power absorption). A Pearson's correlation was used to identify significantly correlated variables which were then inputted into a multiple regression. No assumption violations for the multiple regression existed for any variables. Pre-operative knee flexion and extension strength, TUG time, and age were used in the multiple regression. The multiple regression model statistically significantly predicted peak knee abduction moment, post-operative walking speed, and post-operative knee flexion strength. All four variables added statistically significantly to the prediction p<.05. Pre-operative KOOS values did not correlate with any biomechanical indicators of post-operative success. Age, pre-operative knee flexion and extension strength, and TUG times predicted peak knee abduction moment, which is associated with medial knee joint loading. These findings stress the importance of pre-surgery condition, as stronger individuals achieved better post-operative biomechanical outcomes. Additionally, younger patients had better outcomes, suggesting that surgeons should not delay surgery in younger patients. This delay in surgery may prevent patients from achieving optimal outcomes. Future studies should utilize a hierarchical multiple regression to identify which variables are most predictive


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 8 - 8
4 Jun 2024
Safdar NZ Chapman G Hopwood J Brockett C Redmond A
Full Access

Ankle fusion (AF), a durable intervention for ankle arthritis, has been the management of choice but restricts mobility. Recently, total ankle replacement (TAR) has been offered to patients looking to maintain mobility. The aim was to compare the biomechanics of AF and TAR while walking on inverted and everted slopes which create a greater demand for complex foot mobility than level walking. A ten-camera motion detection setup captured trials as patients walked in both directions over a 5⁰ lateral slope with embedded force plates. Moments (Nm/Kg) across the knee and ankle were exported from Visual 3D in the sagittal and frontal plane, and data were reported as means with 95% confidence intervals. 15 patients were recruited (6 TAR, 9 AF). The median age, follow-up and BMI was 67 years, 4 years and 35.8 kg/m² in AF, and 73 years, 7 years and 28.1 kg/m² in TAR, respectively. During inverted slope walking (4 TAR, 7 AF), abduction moments across (i) the knee: TAR 0.38 (0.37–0.39) vs AF 0.37 (0.27–0.52) and (ii) the ankle: TAR 0.20 (0.13–0.27) vs AF 0.25 (0.18–0.32), and extension moments across (i) the knee: TAR 0.68 (0.38–0.97) vs AF 0.85 (0.69–1.01) and (ii) the ankle: TAR 1.46 (1.30–1.62) vs AF 1.30 (1.08–1.52). During everted walking (5 TAR, 7 AF), abduction moments across (i) the knee: TAR 0.41 (0.30–0.52) vs AF 0.46 (0.27–0.66) and (ii) the ankle: TAR 0.24 (0.11–0.38) vs AF 0.26 (0.18–0.33), and extension moments across (i) the knee: TAR 0.76 (0.54–0.99) vs AF 0.93 (0.72–1.14) and (ii) the ankle: TAR 1.39 (1.19–1.59) vs AF 1.26 (1.04–1.48). There were no differences in abduction moments during inverted or everted slope walking. However, patients with AF had increased extension moments across the knee, particularly on inverted slopes, suggesting that AF creates a greater demand for knee compensation than TAR


Bone & Joint Open
Vol. 2, Issue 6 | Pages 365 - 370
1 Jun 2021
Kolodychuk N Su E Alexiades MM Ren R Ojard C Waddell BS

Aims. Traditionally, acetabular component insertion during total hip arthroplasty (THA) is visually assisted in the posterior approach and fluoroscopically assisted in the anterior approach. The present study examined the accuracy of a new surgeon during anterior (NSA) and posterior (NSP) THA using robotic arm-assisted technology compared to two experienced surgeons using traditional methods. Methods. Prospectively collected data was reviewed for 120 patients at two institutions. Data were collected on the first 30 anterior approach and the first 30 posterior approach surgeries performed by a newly graduated arthroplasty surgeon (all using robotic arm-assisted technology) and was compared to standard THA by an experienced anterior (SSA) and posterior surgeon (SSP). Acetabular component inclination, version, and leg length were calculated postoperatively and differences calculated based on postoperative film measurement. Results. Demographic data were similar between groups with the exception of BMI being lower in the NSA group (27.98 vs 25.2; p = 0.005). Operating time and total time in operating room (TTOR) was lower in the SSA (p < 0.001) and TTOR was higher in the NSP group (p = 0.014). Planned versus postoperative leg length discrepancy were similar among both anterior and posterior surgeries (p > 0.104). Planned versus postoperative abduction and anteversion were similar among the NSA and SSA (p > 0.425), whereas planned versus postoperative abduction and anteversion were lower in the NSP (p < 0.001). Outliers > 10 mm from planned leg length were present in one case of the SSP and NSP, with none in the anterior groups. There were no outliers > 10° in anterior or posterior for abduction in all surgeons. The SSP had six outliers > 10° in anteversion while the NSP had none (p = 0.004); the SSA had no outliers for anteversion while the NSA had one (p = 0.500). Conclusion. Robotic arm-assisted technology allowed a newly trained surgeon to produce similarly accurate results and outcomes as experienced surgeons in anterior and posterior hip arthroplasty. Cite this article: Bone Jt Open 2021;2(6):365–370


Abstract. Objective. Radial to axillary nerve and spinal accessory (XI) to suprascapular nerve (SSN) transfers are standard procedures to restore function after C5 brachial plexus dysfunction. The anterior approach to the SSN may miss concomitant pathology at the suprascapular notch and sacrifices lateral trapezius function, resulting in poor restoration of shoulder external rotation. A posterior approach allows decompression and visualisation of the SSN at the notch and distal coaptation of the medial XI branch. The medial triceps has a double fascicle structure that may be coapted to both the anterior and posterior division of the axillary nerve, whilst preserving the stabilising effect of the long head of triceps at the glenohumeral joint. Reinnervation of two shoulder abductors and two external rotators may confer advantages over previous approaches with improved external rotation range of motion and strength. Methods. Review of the clinical outcomes of 22 patients who underwent a double nerve transfer from XI and radial nerves. Motor strength was evaluated using the MRC scale and grade 4 was defined as the threshold for success. Results. 18/22 patients had adequate follow-up (Mean: 29.5 months). Of these, 72.2% achieved ≥grade 4 power of shoulder abduction and a mean range of motion of 103°. 64.7% achieved ≥grade 4 external rotation with a mean range of motion of 99.6°. Conclusions. The results suggest the use of the combined nerve transfer for restoration of shoulder function via a posterior approach, involving the medial head branch of triceps to the axillary nerve and the XI to SSN


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 22 - 22
7 Nov 2023
Du Plessis J Kazee N Lewis A Steyn S Van Deventer S
Full Access

The choice of whether to perform antegrade intramedullary nailing (IMN) or plate fixation (PF) poses a conundrum for the surgeon who must strike the balance between anatomical restoration while reducing elbow and shoulder functional impairment. Most humeral middle third shaft fractures are amenable to conservative management given the considerable acceptable deformity and anatomical compensation by patients. This study is concerned with the patient reported outcomes regarding shoulder and elbow function for IMN and PF respectively. A prospective cohort study following up all the cases treated surgically for middle third humeral fractures from 2016 to 2022 at a single centre. Telephonically an analogue pain score, an American Shoulder and Elbow Society (ASES) score for shoulder function and the Oxford Elbow score (OES) for elbow function were obtained. One hundred and three patients met the inclusion criteria. Twenty four patients participated in the study, fifteen had IMN (62.5%) and nine had PF (37.5%.). The shoulder function outcomes showed no statistical difference with an average ASES score of sixty-six for the IMN group and sixty-nine for the PF group. Women and employed individuals expressed greater functional impairment. Hand dominance has no impact on the scores of elbow and shoulder function post operatively. The impairment of abduction score post antegrade nailing was higher in the antegrade nailing group than the plated group. The OES demonstrated greater variance in elbow function in the PF group with the IMN group expressing greater elbow disfunction. This study confirms that treatment of middle third humerus shaft fractures by plate fixation is marginally superior to antegrade intramedullary nailing in preserving elbow function and abduction ability


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 76 - 76
11 Apr 2023
Petersen E Rytter S Koppens D Dalsgaard J Bæk Hansen T Larsen NE Andersen M Stilling M
Full Access

In an attempt to alleviate symptoms of the disease, patients with knee osteoarthrosis (KOA) frequently alter their gait patterns. Understanding the underlying pathomechanics and identifying KOA phenotypes is essential for improving treatments. We aimed to investigate altered kinematics in patients with KOA to identify subgroups. Sixty-six patients with symptomatic KOA scheduled for total knee arthroplasty and 12 age-matched healthy volunteers with asymptomatic knees were included. We used k-means to separate the patients based on dynamic radiostereometric assessed knee kinematics. Ligament lesions, KOA score, and clinical outcome were assessed by magnetic resonance imaging, radiographs, and patient reported outcome measures, respectively. We identified four clusters that were supported by clinical characteristics. Compared with the healthy group; The flexion group (n=20): revealed increased flexion, greater adduction, and joint narrowing and consisted primarily of patients with medial KOA. The abduction group (n=17): revealed greater abduction, joint narrowing and included primarily patients with lateral KOA. The anterior draw group (n=10): revealed greater anterior draw, external tibial rotation, lateral tibial shift, adduction, and joint narrowing. This group was composed of patients with medial KOA, some degree of anterior cruciate ligament lesion and the greatest KOA score. The external rotation group (n=19): revealed greater external tibial rotation, lateral tibial shift, adduction, and joint narrowing while no anterior draw was observed. This group included primarily patients with medial collateral and posterior cruciate ligament lesions. Patients with KOA can, based on their gait patterns, be classified into four subgroups, which relate to their clinical characteristics. The findings add to our understanding of associations between disease pathology characteristics in the knee and the pathomechanics in patients with KOA. A next step is to investigate if patients in the pathomechanic clusters have different outcomes following total knee arthroplasty


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 87 - 87
4 Apr 2023
Gehweiler D Pastor T Gueorguiev B Jaeger M Lambert S
Full Access

The periclavicular space is a conduit for the brachial plexus and subclavian-axillary vascular system. Changes in its shape/form generated by alteration in the anatomy of its bounding structures, e.g. clavicle malunion, cause distortion of the containing structures, particularly during arm motion, leading to syndromes of thoracic outlet stenosis etc., or alterations of scapular posture with potential reduction in shoulder function. Aim of this study was developing an in vitro methodology for systematic and repeatable measurements of the clinically poorly characterized periclavicular space during arm motion using CT-imaging and computer-aided 3D-methodologies. A radiolucent frame, mountable to the CT-table, was constructed to fix an upper torso in an upright position with the shoulder joint lying in the isocentre. The centrally osteotomized humerus is fixed to a semi-circular bracket mounted centrally at the end of the frame. All arm movements (ante-/retroversion, abduction/elevation, in-/external rotation) can be set and scanned in a defined and reproducible manner. Clavicle fractures healed in malposition can be simulated by osteotomy and fixation using a titanium/carbon external fixator. During image processing the first rib served as fixed reference in space. Clavicle, scapula and humerus were registered, segmented, and triangulated. The different positions were displayed as superimposed surface meshes and measurements performed automatically. Initial results of an intact shoulder girdle demonstrated that different arm positions including ante-/retroversion and abduction/elevation resulted solely in a transverse movement of the clavicle along/parallel to the first rib maintaining the periclavicular space. A radiolucent frame enabling systematic and reproducible CT scanning of upper torsos in various arm movements was developed and utilized to characterize the effect on the 3D volume of the periclavicular space. Initial results demonstrated exclusively transverse movement of the clavicle along/parallel to the first rib maintaining the periclavicular space during arm positions within a physiological range of motion