header advert
Results 1 - 20 of 906
Results per page:
Bone & Joint Research
Vol. 10, Issue 12 | Pages 759 - 766
1 Dec 2021
Nicholson JA Oliver WM MacGillivray TJ Robinson CM Simpson AHRW

Aims. The aim of this study was to establish a reliable method for producing 3D reconstruction of sonographic callus. Methods. A cohort of ten closed tibial shaft fractures managed with intramedullary nailing underwent ultrasound scanning at two, six, and 12 weeks post-surgery. Ultrasound capture was performed using infrared tracking technology to map each image to a 3D lattice. Using echo intensity, semi-automated mapping was performed to produce an anatomical 3D representation of the fracture site. Two reviewers independently performed 3D reconstructions and kappa coefficient was used to determine agreement. A further validation study was undertaken with ten reviewers to estimate the clinical application of this imaging technique using the intraclass correlation coefficient (ICC). Results. Nine of the ten patients achieved union at six months. At six weeks, seven patients had bridging callus of ≥ one cortex on the 3D reconstruction and when present all achieved union. Compared to six-week radiographs, no bridging callus was present in any patient. Of the three patients lacking sonographic bridging callus, one went onto a nonunion (77.8% sensitive and 100% specific to predict union). At 12 weeks, nine patients had bridging callus at ≥ one cortex on 3D reconstruction (100%-sensitive and 100%-specific to predict union). Presence of sonographic bridging callus on 3D reconstruction demonstrated excellent reviewer agreement on ICC at 0.87 (95% confidence interval 0.74 to 0.96). Conclusion. 3D fracture reconstruction can be created using multiple ultrasound images in order to evaluate the presence of bridging callus. This imaging modality has the potential to enhance the usability and accuracy of identification of early fracture healing. Cite this article: Bone Joint Res 2021;10(12):759–766


Bone & Joint Research
Vol. 8, Issue 7 | Pages 304 - 312
1 Jul 2019
Nicholson JA Tsang STJ MacGillivray TJ Perks F Simpson AHRW

Objectives. The aim of this study was to review the current evidence and future application for the role of diagnostic and therapeutic ultrasound in fracture management. Methods. A review of relevant literature was undertaken, including articles indexed in PubMed with keywords “ultrasound” or “sonography” combined with “diagnosis”, “fracture healing”, “impaired fracture healing”, “nonunion”, “microbiology”, and “fracture-related infection”. Results. The use of ultrasound in musculoskeletal medicine has expanded rapidly over the last two decades, but the diagnostic use in fracture management is not routinely practised. Early studies have shown the potential of ultrasound as a valid alternative to radiographs to diagnose common paediatric fractures, to detect occult injuries in adults, and for rapid detection of long bone fractures in the resuscitation setting. Ultrasound has also been shown to be advantageous in the early identification of impaired fracture healing; with the advent of 3D image processing, there is potential for wider adoption. Detection of implant-related infection can be improved by ultrasound mediated sonication of microbiology samples. The use of therapeutic ultrasound to promote union in the management of acute fractures is currently a controversial topic. However, there is strong in vitro evidence that ultrasound can stimulate a biological effect with potential clinical benefit in established nonunions, which supports the need for further investigation. Conclusion. Modern ultrasound image processing has the potential to replace traditional imaging modalities in several areas of trauma practice, particularly in the early prediction of impaired fracture healing. Further understanding of the therapeutic application of ultrasound is required to understand and identify the use in promoting fracture healing. Cite this article: J. A. Nicholson, S. T. J. Tsang, T. J. MacGillivray, F. Perks, A. H. R. W. Simpson. What is the role of ultrasound in fracture management? Diagnosis and therapeutic potential for fractures, delayed unions, and fracture-related infection. Bone Joint Res 2019;8:304–312. DOI: 10.1302/2046-3758.87.BJR-2018-0215.R2


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 78 - 78
1 Dec 2020
Dandois F Taylan O D'hooge J Vandenneucker H Slane L Scheys L
Full Access

In-situ assessment of collateral ligaments strain could be key to improving total knee arthroplasty outcomes by improving the ability of surgeons to properly balance the knee intraoperatively. Ultrasound (US) speckle tracking methods have shown promise in their capability to measure in-situ soft tissue strain in large tendons but prior work has also highlighted the challenges that arise when attempting to translate these approaches to the in-situ assessment of collateral ligaments strain. Therefore, the aim of this project was to develop and validate an US speckle tracking method to specifically assess in-situ strains of both the MCL and LCL. We hypothesize that coefficients of determination (R. 2. ) would be above 0.90 with absolute differences below 0.50% strain for the comparison between US-based and the reference strain, with better results expected for the LCL compared with the MCL. Five cadaveric legs with total knee implants (NH019 2017-02-03) were submitted to a varus (LCL) and valgus (MCL) ramped loading (0 – 40N). Ultrasound radiofrequency (rf) data and reference surface strains data, obtained with 3D digital image correlation (DIC), were collected synchronously. Prior to processing, US data were qualitatively assessed and specimens displaying substantial imaging artefacts were discarded, leaving five LCL and three MCL specimens in the analysis. Ultrasound rf data were processed in Matlab (The MathWorks, Inc., Natick, MA) with a custom-built speckle tracking approach adapted from a method validated on larger tendons and based on normalized cross-correlation. Digital image correlation data were processed with commercial software VIC3D (Correlated Solutions, Inc., Columbia, SC). To optimize speckle tracking, several tracking parameters were tested: kernel and search window size, minimal correlation coefficient and simulated frame rate. Parameters were ranked according to three comparative measures between US- and DIC-based strains: R. 2. , mean absolute error and strains differences at 40N. Parameters with best average rank were considered as optimal. To quantify the agreement between US- and DIC-based strain of each specimen, the considered metrics were: R. 2. , mean absolute error and strain differences at 40N. The LCL showed a good agreement with a high average R. 2. (0.97), small average mean absolute difference (0.37%) and similar strains at 40N (DIC = 2.92 ± 0.10%; US = 2.99 ± 1.16%). The US-based speckle tracking method showed worse performance for the MCL with a lower average correlation (0.55). Such an effect has been observed previously and may relate to the difficulty in acquiring sufficient image quality for tracking the MCL compared to the LCL, which likely arises due to structural or mechanical differences; notably MCL is larger, thinner, more wrapped around the bone and stretches less. However, despite these challenges, the MCL tracking still showed small average mean absolute differences (0.44%) and similar strains at 40N (DIC = 1.48 ± 0.06%; US = 1.44 ± 1.89%). We conclude that the ultrasound speckle tracking method developed is ready to be used as a tool to assess in-situ strains of LCL. Concerning the MCL strain assessment, despite some promising results in terms of strain differences, further work on acquisition could be beneficial to reach similar performance


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 44 - 44
1 Dec 2020
Torgutalp ŞŞ Korkusuz F
Full Access

Background. Although there are predictive equations that estimate the total fat mass obtained from multiple-site ultrasound (US) measurements, the predictive equation of total fat mass has not been investigated solely from abdominal subcutaneous fat thickness. Therefore, the aims of this study were; (1) to develop regression-based prediction equations based on abdominal subcutaneous fat thickness for predicting fat mass in young- and middle-aged adults, and (2) to investigate the validity of these equations to be developed. Methods. The study was approved by the Local Research Ethics Committee (Decision number: GO 19/788). Twenty-seven males (30.3 ± 8.7 years) and eighteen females (32.4 ± 9.5 years) were randomly divided into two groups as the model prediction group (19 males and 12 females) and the validation group (8 males and 6 females). Total body fat mass was determined by dual-energy X-ray absorptiometry (DXA). Abdominal subcutaneous fat thickness was measured by US. The predictive equations for total fat mass from US were determined as fat thickness (in mm) × standing height (in m). Statistical analyses were performed using R version 4.0.0. The association between the total fat mass and the abdominal subcutaneous fat thickness was interpreted using the Pearson test. The linear regression analysis was used to predict equations for total body fat mass from the abdominal subcutaneous fat thickness acquired by US. Then these predictive equations were applied to the validation group. The paired t-test was used to examine the difference between the measured and the predicted fat masses, and Lin's concordance correlation coefficient (CCC) was used as a further measure of agreement. Results. There was a significant positive moderate correlation between the total fat mass and the abdominal subcutaneous fat thickness × height in the model prediction group of males (r = 0.588, p = 0.008), whereas significant positive very strong correlation was observed in the model prediction group of females (r = 0.896, p < 0.001). Predictive equations for DXA-measured total body fat mass from abdominal subcutaneous fat thickness using US were as follows: for males “Fat mass-DXA = 0.276 × (Fat thickness-US × Height) + 17.221” (R. 2. = 0.35, SEE = 3.6, p = 0.008); for females “Fat mass-DXA = 0.694 x (Fat thickness-US × Height) + 7.085” (R. 2. = 0.80, SEE = 2.8, p < 0.001). When fat mass prediction equations were applied to the validation groups, measured- and estimated-total fat masses in males and females were found similar (p = 0.9, p = 0.5, respectively). A good level of agreement between measurements in males and females was attained (CCC = 0.84, CCC = 0.76, respectively). Conclusion. We developed and validated prediction equations that are convenient for determining total fat masses in young- and middle-aged adults using abdominal subcutaneous fat thickness obtained from the US. The abdominal subcutaneous fat thickness obtained from a single region by US might provide a noninvasive quick and easy evaluation not only in clinical settings but also on the field


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 120 - 120
10 Feb 2023
Mohammed K Oorschot C Austen M O'Loiughlin E
Full Access

We test the clinical validity and financial implications of the proposed Choosing Wisely statement: “Using ultrasound as a screening test for shoulder instability is inappropriate in people under 30 years of age, unless there is clinical suspicion of a rotator cuff tear.”. A retrospective chart review from a specialist shoulder surgeon's practice over a two-year period recorded 124 patients under the age of 30 referred with shoulder instability. Of these, forty-one had already had ultrasound scans performed prior to specialist review. The scan results and patient files were reviewed to determine the reported findings on the scans and whether these findings were clinically relevant to diagnosis and decision-making. Comparison was made with subsequent MRI scan results. The data, obtained from the Accident Compensation Corporation (ACC), recorded the number of cases and costs incurred for ultrasound scans of the shoulder in patients under 30 years old over a 10-year period. There were no cases where the ultrasound scan was considered useful in decision-making. No patient had a full thickness rotator cuff tear. Thirty-nine of the 41 patients subsequently had MRI scans. The cost to the ACC for funding ultrasound scans in patients under 30 has increased over the last decade and exceeded one million dollars in the 2020/2021 financial year. In addition, patients pay a surcharge for this test. The proposed Choosing Wisely statement is valid. This evidence supports that ultrasound is an unnecessary investigation for patients with shoulder instability unless there is clinical suspicion of a rotator cuff tear. Ultrasound also incurs costs to the insurer (ACC) and the patient. We recommend x-rays and, if further imaging is indicated, High Tech Imaging with MRI and sometimes CT scans in these patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 40 - 40
17 Nov 2023
Kuder I Jones G Rock M van Arkel R
Full Access

Abstract. Objectives. Ultrasound speckle tracking is a safe and non-invasive diagnostic tool to measure soft tissue deformation and strain. In orthopaedics, it could have broad application to measure how injury or surgery affects muscle, tendon or ligament biomechanics. However, its application requires custom tuning of the speckle-tracking algorithm then validation against gold-standard reference data. Implementing an experiment to acquire these data takes months and is expensive, and therefore prohibits use for new applications. Here, we present an alternative optimisation approach that automatically finds suitable machine and algorithmic settings without requiring gold-standard reference data. Methods. The optimisation routine consisted of two steps. First, convergence of the displacement field was tested to exclude the settings that would not track the underlying tissue motion (e.g. frame rates that were too low). Second, repeatability was maximised through a surrogate optimisation scheme. All settings that could influence the strain calculation were included, ranging from acquisition settings to post-processing smoothing and filtering settings, totalling >1,000,000 combinations of settings. The optimisation criterion minimised the normalised standard deviation between strain maps of repeat measures. The optimisation approach was validated for the medial collateral ligament (MCL) with quasi-static testing on porcine joints (n=3), and dynamic testing on a cadaveric human knee (n=1, female, aged 49). Porcine joints were fully dissected except for the MCL and loaded in a material-testing machine (0 to 3% strain at 0.2 Hz), which was captured using both ultrasound (>14 repeats per specimen) and optical digital image correlation (DIC). For the human cadaveric knee (undissected), 3 repeat ultrasound acquisitions were taken at 18 different anterior/posterior positions over the MCL while the knee was extended/flexed between 0° and 90° in a knee extension rig. Simultaneous optical tracking recorded the position of the ultrasound transducer, knee kinematics and the MCL attachments (which were digitised under direct visualisation post testing). Half of the data collected was used for optimisation of the speckle tracking algorithms for the porcine and human MCLs separately, with the remaining unseen data used as a validation test set. Results. For the porcine MCLs, ultrasound strains closely matched DIC strains (R. 2. > 0.98, RMSE < 0.59%) (Figure 1A). For the human MCL (Figure 1B), ultrasound strains matched the strains estimated from the optically tracked displacements of the MCL attachments. Furthermore, strains developed during flexion were highly correlated with AP position (R = 0.94) with strains decreasing the further posterior the transducer was on the ligament. This is in line with previously reported length change values for the posterior, intermediate and anterior bundles of the MCL. Conclusions. Ultrasound speckle tracking algorithms can be adapted for new applications without ground-truth data by using an optimisation approach that verifies displacement field convergence then minimises variance between repeat measurements. This optimisation routine was insensitive to anatomical variation and loading conditions, working for both porcine and human MCLs, and for quasi-static and dynamic loading. This will facilitate research into changes in musculoskeletal tissue motion due to abnormalities or pathologies. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 112 - 112
11 Apr 2023
Oliver W Nicholson J Bell K Carter T White T Clement N Duckworth A Simpson H
Full Access

The primary aim was to assess the reliability of ultrasound in the assessment of humeral shaft fracture healing. The secondary aim was to estimate the accuracy of ultrasound assessment in predicting humeral shaft nonunion. Twelve patients (mean age 54yrs [20–81], 58% [n=7/12] female) with a non-operatively managed humeral diaphyseal fracture were prospectively recruited and underwent ultrasound scanning at six and 12wks post-injury. Scans were reviewed by seven blinded observers to evaluate the presence of sonographic callus. Intra- and inter-observer reliability were determined using the weighted kappa and intraclass correlation coefficient (ICC). Accuracy of ultrasound assessment in nonunion prediction was estimated by comparing scans for patients that united (n=10/12) with those that developed a nonunion (n=2/12). At both six and 12wks, sonographic callus was present in 11 patients (10 united, one developed a nonunion) and sonographic bridging callus (SBC) was present in seven patients (all united). Ultrasound assessment demonstrated substantial intra- (6wk kappa 0.75, 95% CI 0.47-1.03; 12wk kappa 0.75, 95% CI 0.46-1.04) and inter-observer reliability (6wk ICC 0.60, 95% CI 0.38-0.83; 12wk ICC 0.76, 95% CI 0.58-0.91). Absence of sonographic callus demonstrated a sensitivity of 50%, specificity 100%, positive predictive value (PPV) 100% and negative predictive value (NPV) 91% in nonunion prediction (accuracy 92%). Absence of SBC demonstrated a sensitivity of 100%, specificity 70%, PPV 40% and NPV 100% (accuracy 75%). Of three patients at risk of nonunion based on reduced radiographic callus formation (Radiographic Union Score for HUmeral fractures <8), one had SBC on 6wk ultrasound (and united) and the other two had non-bridging or absent sonographic callus (both developed a nonunion). Ultrasound assessment of humeral shaft fracture healing was reliable and predictive of nonunion, and may be a useful tool in defining the risk of nonunion among patients with reduced radiographic callus formation


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 488 - 488
1 Apr 2004
Biggs D Haber M Seeff J
Full Access

Introduction Ultrasound is a readily available and widely used tool in the investigation of rotator cuff pathology in the shoulder. Reports in the literature as to the diagnostic accuracy of ultrasound in diagnosing cuff tears vary widely. Accuracy rates varying from 50% to 100% have been reported. Most reports reflect the accuracy rates from a single sub-specialized institution. Method Sity-one consecutive patients with rotator cuff pathology diagnosed on ultrasound, underwent arthroscopy of the shoulder and rotator cuff repair, if a full thickness tear was found at surgery. Most patients had their ultrasound ordered by the referring doctor, prior to my initial review. The ultrasounds were performed at various suburban practices. Most were performed at branch practices of one of the three ‘corporate’ practices in Sydney. All full thickness tears were repaired arthroscopically. Results Ultrasound correctly identified rotator cuff tears in 80.3%. Four of 61 patients (6.6%) were reported as having partial thickness tears and at surgery were found to have small full-thickness tears. Six of 61 patients (9.8%) had small full thickness tears diagnosed on ultrasound, but were found to have partial thickness tears at surgery. One patient (1.6%) had an ultrasound diagnosis of a tear but had an intact tendon at surgery. One patient (1.6%) was found to have a full thickness tear with an ultrasound that reported an intact tendon. Conclusions Ultrasound is a valuable tool on the investigation of patients with rotator cuff pathology. It is not reliable in differentiating partial thickness from small full thickness cuff tears. This differentiation is not critical and should not significantly change the patient’s treatment. Reasons for false positive and false negative ultrasounds will be given. Ultrasound for the diagnosis of rotator cuff tendon tears, as performed in suburban practices, is accurate in up to 97% of cases


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 39 - 39
1 Dec 2017
Alsinan Z Cieslak M He P Rupertus N Spinelli C Vives M Hacihalioglu I
Full Access

In recent years, there has been a growing interest to incorporate ultrasound into computer assisted orthopaedic surgery procedures in order to provide non-ionizing intra-operative imaging alternative to traditional fluoroscopy. However, identification of bone boundaries still continues to be a challenging process due low signal to noise ratio and imaging artifacts. The quality of the collected images also depends on the orientation of the ultrasound transducer with respect to the imaged bone surface. Shadow region is an important feature indicating the presence of a bone surface in the collected ultrasound data. In this work, we propose a framework for the enhancement of shadow regions from extended field of view spine ultrasound data. First bone surfaces are enhanced using a combination of local phase based image features. The combination of the phase features provides a more compact representation of vertebrae bone surfaces with supressed soft tissue interfaces. These enhanced features are used as an input to a L1 norm based regularisation method which emphasised uncertainty in the shadow regions. Validation on phantom and in vivo experiments achieve a mean dice coefficient value of 0.93 and 0.9 respectively


Bone & Joint Open
Vol. 3, Issue 11 | Pages 913 - 923
28 Nov 2022
Hareendranathan AR Wichuk S Punithakumar K Dulai S Jaremko J

Aims. Studies of infant hip development to date have been limited by considering only the changes in appearance of a single ultrasound slice (Graf’s standard plane). We used 3D ultrasound (3DUS) to establish maturation curves of normal infant hip development, quantifying variation by age, sex, side, and anteroposterior location in the hip. Methods. We analyzed 3DUS scans of 519 infants (mean age 64 days (6 to 111 days)) presenting at a tertiary children’s hospital for suspicion of developmental dysplasia of the hip (DDH). Hips that did not require ultrasound follow-up or treatment were classified as ‘typically developing’. We calculated traditional DDH indices like α angle (α. SP. ), femoral head coverage (FHC. SP. ), and several novel indices from 3DUS like the acetabular contact angle (ACA) and osculating circle radius (OCR) using custom software. Results. α angle, FHC, and ACA indices increased and OCR decreased significantly by age in the first four months, mean α. SP. rose from 62.2° (SD 5.7°) to 67.3° (SD 5.2°) (p < 0.001) in one- to eight- and nine- to 16-week-old infants, respectively. Mean α. SP. and mean FHC. SP. were significantly, but only slightly, lower in females than in males. There was no statistically significant difference in DDH indices observed between left and right hip. All 3DUS indices varied significantly between anterior and posterior section of the hip. Mean 3D indices of α angle and FHC were significantly lower anteriorly than posteriorly: α. Ant. = 58.2° (SD 6.1°), α. Post. = 63.8° (SD 6.3°) (p < 0.001), FHC. Ant. = 43.0 (SD 7.4), and FHC. Post. = 55.4° (SD 11.2°) (p < 0.001). Acetabular rounding measured byOCR indices was significantly greater in the anterior section of the hip (p < 0.001). Conclusion. We used 3DUS to show that hip shape and normal growth pattern vary significantly between anterior and posterior regions, by magnitudes similar to age-related changes. This highlights the need for careful selection of the Graf plane during 2D ultrasound examination. Whole-joint evaluation by obtaining either 3DUS or manual ‘sweep’ video images provides more comprehensive DDH assessment. Cite this article: Bone Jt Open 2022;3(11):913–923


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 136 - 136
2 Jan 2024
Manferdini C Gabusi E Dolzani P Trucco D Lenzi E D'Atri G Vannozzi L Cafarelli A Ricotti L Lisignoli G
Full Access

In cartilage tissue engineering (TE),new solutions are needed to effectively drive chondrogenic differentiation of mesenchymal stromal cells in both normal and inflammatory milieu. Ultrasound waves represent an interesting tool to facilitate chondrogenesis. In particular, low intensity pulsed ultrasound (LIPUS)has been shown to regulate the differentiation of adipose mesenchymal stromal cells. Hydrogels are promising biomaterials capable of encapsulating MSCs by providing an instructive biomimetic environment, graphene oxide (GO) has emerged as a promising nanomaterial for cartilage TE due to its chondroinductive properties when embedded in polymeric formulations, and piezoelectric nanomaterials, such as barium titanate nanoparticles (BTNPs),can be exploited as nanoscale transducers capable of inducing cell growth/differentiation. The aim of this study was to investigate the effect of dose-controlled LIPUS in counteracting inflammation and positively committing chondrogenesis of ASCs embedded in a 3D piezoelectric hydrogel. ASCs at 2*10. 6. cells/mL were embedded in a 3D VitroGel RGD. ®. hydrogel without nanoparticles (Control) or doped with 25 µg/ml of GO nanoflakes and 50 µg/ml BTNPs.The hydrogels were exposed to basal or inflammatory milieu (+IL1β 10ng/ml)and then to LIPUS stimulation every 2 days for 10 days of culture. Hydrogels were chondrogenic differentiated and analyzed after 2,10 and 28 days. At each time point cell viability, cytotoxicity, gene expression and immunohistochemistry (COL2, aggrecan, SOX9, COL1)and inflammatory cytokines were evaluated. Ultrasound stimulation significantly induced chondrogenic differentiation of ASCs loaded into 3D piezoelectric hydrogels under basal conditions: COL2, aggrecan and SOX9 were significantly overexpressed, while the fibrotic marker COL1 decreased compared to control samples. LIPUS also has potent anti-inflammatory effects by reducing IL6 and IL8 and maintaining its ability to boost chondrogenesis. These results suggest that the combination of LIPUS and piezoelectric hydrogels promotes the differentiation of ASCs encapsulated in a 3D hydrogel by reducing the inflammatory milieu, thus representing a promising tool in the field of cartilage TE. Acknowledgements: This work received funding from the European Union's Horizon 2020 research and innovation program, grant agreement No 814413, project ADMAIORA (AdvanceD nanocomposite MAterIals for in situ treatment and ultRAsound-mediated management of osteoarthritis)


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 84 - 84
1 Dec 2022
du Toit C Dima R Jonnalagadda M Fenster A Lalone E
Full Access

The opposable thumb is one of the defining characteristics of human anatomy and is involved in most activities of daily life. Lack of optimal thumb motion results in pain, weakness, and decrease in quality of life. First carpometacarpal (CMC1) osteoarthritis (OA) is one of the most common sites of OA. Current clinical diagnosis and monitoring of CMC1 OA disease are primarily aided by X-ray radiography; however, many studies have reported discrepancies between radiographic evidence of CMC1 OA and patient-related outcomes of pain and disability. Radiographs lack soft-tissue contrast and are insufficient for the detection of early characteristics of OA such as synovitis, which play a key role in CMC OA disease progression. Magnetic resonance imaging (MRI) and two-dimensional ultrasound (2D-US) are alternative options that are excellent for imaging soft tissue pathology. However, MRI has high operating costs and long wait-times, while 2D-US is highly operator dependent and provides 2D images of 3D anatomical structures. Three-dimensional ultrasound imaging may be an option to address the clinical need for a rapid and safe point of care imaging device. The purpose of this research project is to validate the use of mechanically translated 3D-US in CMC OA patients to assess the measurement capabilities of the device in a clinically diverse population in comparison to MRI. Four CMC1-OA patients were scanned using the 3D-US device, which was attached to a Canon Aplio i700 US machine with a 14L5 linear transducer with a 10MHz operating frequency and 58mm. Complimentary MR images were acquired using a 3.0 T MRI system and LT 3D coronal photon dense cube fat suppression sequence was used. The volume of the synovium was segmented from both 3D-US and MR images by two raters and the measured volumes were compared to find volume percent differences. Paired sample t-test were used to determine any statistically significant differences between the volumetric measurements observed by the raters and in the measurements found using MRI vs. 3D-US. Interclass Correlation Coefficients were used to determine inter- and intra-rater reliability. The mean volume percent difference observed between the two raters for the 3D-US and MRI acquired synovial volumes was 1.77% and 4.76%, respectively. The smallest percent difference in volume found between raters was 0.91% and was from an MR image. A paired sample t-test demonstrated that there was no significant difference between the volumetric values observed between MRI and 3D-US. ICC values of 0.99 and 0.98 for 3D-US and MRI respectively, indicate that there was excellent inter-rater reliability between the two raters. A novel application of a 3D-US acquisition device was evaluated using a CMC OA patient population to determine its clinical feasibility and measurement capabilities in comparison to MRI. As this device is compatible with any commercially available ultrasound machine, it increases its accessibility and ease of use, while proving a method for overcoming some of the limitations associated with radiography, MRI, and 2DUS. 3DUS has the potential to provide clinicians with a tool to quantitatively measure and monitor OA progression at the patient's bedside


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_2 | Pages 1 - 1
1 Mar 2022
Lacey A Chiphang A
Full Access

16 to 34% of the population suffer from shoulder pain, the most common cause being rotator cuff tears. NICE guidance recommends using ultrasound scan (USS) or MRI to assess these patients, but does not specify which is preferable. This study assesses the accuracy of USS and MRI in rotator cuff tears in a DGH, to establish the most appropriate imaging modality. Patients who had at least two of shoulder ultrasound, MRI or arthroscopy within a seven month period (n=55) were included in this retrospective study. Sensitivity, Specificity, Positive Predictive Value (PPV) and Negative Predictive Value (NPV) were calculated using arthroscopy as the true result, and kappa coefficients calculated for each pairing. 59 comparisons were made in total. Sensitivity for MRI in full supraspinatus tears was 0.83, and for USS 0.75. Specificity for MRI in these tears was 0.75, and for USS 0.83. Values were much lower in other tears, which occurred less frequently. USS and MRI completely agreed with each other 61.3% of the time. Both modalities were only completely accurate 50% of the time. Kappa coefficient between arthroscopy and MRI for supraspinatus tears was 0.658, and for USS was 0.615. There was no statistical difference between MRI and USS sensitivity or specificity (p=1), suggesting that one modality cannot be recommended over the other for full supraspinatus tears. They also do not tend to corroborate one another, suggesting that there is no benefit from doing both scans. Further research is needed to see how both modalities can be improved to increase their accuracy


Bone & Joint Research
Vol. 10, Issue 2 | Pages 113 - 121
1 Feb 2021
Nicholson JA Oliver WM MacGillivray TJ Robinson CM Simpson AHRW

Aims. To evaluate if union of clavicle fractures can be predicted at six weeks post-injury by the presence of bridging callus on ultrasound. Methods. Adult patients managed nonoperatively with a displaced mid-shaft clavicle were recruited prospectively. Ultrasound evaluation of the fracture was undertaken to determine if sonographic bridging callus was present. Clinical risk factors at six weeks were used to stratify patients at high risk of nonunion with a combination of Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) ≥ 40, fracture movement on examination, or absence of callus on radiograph. Results. A total of 112 patients completed follow-up at six months with a nonunion incidence of 16.7% (n = 18/112). Sonographic bridging callus was detected in 62.5% (n = 70/112) of the cohort at six weeks post-injury. If present, union occurred in 98.6% of the fractures (n = 69/70). If absent, nonunion developed in 40.5% of cases (n = 17/42). The sensitivity to predict union with sonographic bridging callus at six weeks was 73.4% and the specificity was 94.4%. Regression analysis found that failure to detect sonographic bridging callus at six weeks was associated with older age, female sex, simple fracture pattern, smoking, and greater fracture displacement (Nagelkerke R. 2. = 0.48). Of the cohort, 30.4% (n = 34/112) had absent sonographic bridging callus in addition to one or more of the clinical risk factors at six weeks that predispose to nonunion. If one was present the nonunion rate was 35%, 60% with two, and 100% when combined with all three. Conclusion. Ultrasound combined with clinical risk factors can accurately predict fracture healing at six weeks following a displaced midshaft clavicle fracture. Cite this article: Bone Joint Res 2021;10(2):113–121


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 41 - 41
17 Nov 2023
Samir A Abdelghany A Metwally A
Full Access

Abstract. Objectives. To compare the effectiveness of phonophoresis (PH) and conventional therapeutic ultrasound (US) on the functional and pain outcomes of patients with knee osteoarthritis. Methods. We conducted an electronic search through PubMed, Cochrane Central Register of Clinical Trials (CENTRAL), Web of Science (WOS), and Scopus databases. We screened the retrieved articles to include only English full-text randomized controlled trials that examined the effect of phonophoresis versus conventional therapeutic ultrasound on patients with knee osteoarthritis. Two reviewers screened, extracted the data, and independently assessed the quality of the included articles. Results. A total of five randomized controlled trials met our inclusion criteria out of 267 studies screened. Our results showed no statistically significant differences between the PH and US groups (1), (2), (3),(4), and (5). The PH group demonstrated more significant effects than the UT group in reducing VAS pain scores (P=0.009) and improving WOMAC scores, although this did not reach the level of significance (P=0.143) (5). In the long term, PH therapy was found to be superior to US in improving painless walking duration and distance VAS scores (p=0.034, 0.017) respectively, as well as walking and resting walking VAS scores (p=0.03, 0.007) respectively, which were found to be permanent (3). Conclusions. Both therapies improve pain and function. However, we suggest conducting more high-quality trials with larger sample sizes and do not recommend the use of these therapies in clinical practice due to limitations in gender selection and high risk of bias. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 116 - 116
1 Nov 2021
Manferdini C Gabusi E Trucco D Dolzani P Saleh Y Cafarelli A Ricotti L Lisignoli G
Full Access

Introduction. Articular cartilage injuries have a limited potential to heal and, over time, may lead to osteoarthritis, an inflammatory and degenerative joint disease associated with activity-related pain, swelling, and impaired mobility. Regeneration and restoration of the joint tissue functionality remain unmet challenges. Stem cell-based tissue engineering is a promising paradigm to treat cartilage degeneration. In this context, hydrogels have emerged as promising biomaterials, due to their biocompatibility, ability to mimic the tissue extracellular matrix and excellent permeability. Different stimulation strategies have been investigated to guarantee proper conditions for mesenchymal stem cell differentiation into chondrocytes, including growth factors, cell-cell interactions, and biomaterials. An interesting tool to facilitate chondrogenesis is external ultrasound stimulation. In particular, low-intensity pulsed ultrasound (LIPUS) has been demonstrated to have a role in regulating the differentiation of adipose mesenchymal stromal cells (ASCs). However, chondrogenic differentiation of ASCs has been never associated to a precisely measured ultrasound dose. In this study, we aimed to investigate whether dose-controlled LIPUS is able to influence chondrogenic differentiation of ASCs embedded in a 3D hydrogel. Materials and Methods. Human adipose mesenchymal stromal cells at 2∗10. 6. cells/mL were embedded in a hydrogel ratio 1:2 (VitroGel RGD®) and exposed to LIPUS stimulation (frequency: 1 MHz, intensity: 250 mW/cm. 2. , duty cycle: 20%, pulse repetition frequency: 1 kHz, stimulation time: 5 min) in order to assess its influence on cell differentiation. Hydrogel-loaded ASCs were cultured and differentiated for 2, 7, 10 and 28 days. At each time point cell viability (Live&Dead), metabolic activity (Alamar Blue), cytotoxicity (LDH), gene expression (COL2, aggrecan, SOX9, and COL1), histology and immunohistochemistry (COL2, aggrecan, SOX9, and COL1) were evaluated respect to a non-stimulated control. Results. Histological analysis evidenced a uniform distribution of ASCs both at the periphery and at the center of the hydrogel. Live & Dead test evidenced that the encapsulated ASCs were viable, with no signs of cytotoxicity. We found that LIPUS induced chondrogenesis of ASCs embedded in the hydrogel, as demonstrated by increased expression of COL2, aggrecan and SOX9 genes and proteins, and decreased expression of COL1 respect to the non-stimulated control. Conclusions. These results suggest that the LIPUS treatment could be a valuable tool in cartilage tissue engineering, to push the differentiation of ASCs encapsulated in a 3D hydrogel


Bone & Joint Research
Vol. 13, Issue 7 | Pages 332 - 341
5 Jul 2024
Wang T Yang C Li G Wang Y Ji B Chen Y Zhou H Cao L

Aims. Although low-intensity pulsed ultrasound (LIPUS) combined with disinfectants has been shown to effectively eliminate portions of biofilm in vitro, its efficacy in vivo remains uncertain. Our objective was to assess the antibiofilm potential and safety of LIPUS combined with 0.35% povidone-iodine (PI) in a rat debridement, antibiotics, and implant retention (DAIR) model of periprosthetic joint infection (PJI). Methods. A total of 56 male Sprague-Dawley rats were established in acute PJI models by intra-articular injection of bacteria. The rats were divided into four groups: a Control group, a 0.35% PI group, a LIPUS and saline group, and a LIPUS and 0.35% PI group. All rats underwent DAIR, except for Control, which underwent a sham procedure. General status, serum biochemical markers, weightbearing analysis, radiographs, micro-CT analysis, scanning electron microscopy of the prostheses, microbiological analysis, macroscope, and histopathology evaluation were performed 14 days after DAIR. Results. The group with LIPUS and 0.35% PI exhibited decreased levels of serum biochemical markers, improved weightbearing scores, reduced reactive bone changes, absence of viable bacteria, and decreased inflammation compared to the Control group. Despite the greater antibiofilm activity observed in the PI group compared to the LIPUS and saline group, none of the monotherapies were successful in preventing reactive bone changes or eliminating the infection. Conclusion. In the rat model of PJI treated with DAIR, LIPUS combined with 0.35% PI demonstrated stronger antibiofilm potential than monotherapy, without impairing any local soft-tissue. Cite this article: Bone Joint Res 2024;13(7):332–341


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 78 - 78
1 Apr 2019
Dessinger G Mahfouz M Fatah EEA Johnson J Komistek R
Full Access

Introduction. At present, orthopaedic surgeons utilize either CT, MRI or X-ray for imaging a joint. Unfortunately, CT and MRI are quite expensive, non weight-bearing and the orthopaedic surgeon does not receive revenue for these procedures. Although x-rays are cheaper, similar to CT scans, patients incur radiation. Also, all three of these imaging modalities are static. More recently, a new ultrasound technology has been developed that will allow a surgeon to image their patients in 3D. The objective of this study is to highlight the new opportunity for orthopaedic surgeons to use 3D ultrasound as alternative to CT, MRI and X-rays. Methods. The 3D reconstruction process utilizes statistical shape atlases in conjunction with the ultrasound RF data to build the patient anatomy in real-time. The ultrasound RF signals are acquired using a linear transducer. Raw RF data is then extracted across each scan line. The transducer is tracked using a 3D tracking system. The location and orientation for each scan line is calculated using the tracking data and known position of the tracker relative to the signal. For each scan line, a detection algorithm extracts the location on the signal of the bone boundary, if any exists. Throughout the scan process, a 3D point cloud is created for each detected bone signal. Using a statistical bone atlas for each anatomy, the patient specific surface is reconstruction by optimizing the geometry to match the point cloud. Missing regions are interpolated from the bone atlas. To validate reconstructed models output models are then compared to models generated from 3D imaging, including CT and MRI. Results. 3D ultrasound, which now has FDA approval in the United States, is presently available for an orthopaedic surgeon to use. Error analyses have been conducted in comparison to MRI and CT scans and revealed that 3D ultrasound has a similar accuracy of less than 1.0 mm in the creation of a 3D bone and soft-tissues. Unlike CT and MRI scans that take in excess of 2–3 weeks to create human bones, 3D ultrasound creates bones in 4–6 minutes. Once the bones are created, the surgeon can assess bone quality, ligament and cartilage conditions, assess osteophytes, fractures and guide needles into the 3D joint space. The creation of 3D bones has been accurately assessed for the spine, shoulder, knee, hip and ankle joints. A 3D joint pre-operative planning module has also been developed for a surgeon to size and position components before surgery. Discussion. 3D ultrasound is an exciting new imaging technology available for orthopaedic surgeons to use in their practice. Existing CPT codes are readily available for 3D ultrasound procedures. A surgeon can now evaluate and diagnose bone and soft- tissue conditions, in 3D, using ultrasound, which is safer and is an easier procedure compared to CT, MRI and X-rays. This new ultrasound technology is a highly accurate imaging technique that will allow a surgeon to diagnose bone and soft-tissue concerns in 3D, under weight-bearing, dynamic conditions and guide needle injections to correct location, in 3D


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 22 - 22
1 Jul 2020
Tsang J Gwynne P Gallagher M Simpson H
Full Access

Staphylococcus aureus is responsible for 60–70% infections of surgical implants and prostheses in Orthopaedic surgery, with cumulative treatment costs for all prosthetic joint infections estimated to be ∼ $1 billion per annum (UK and North America). Its ability to develop resistance or tolerance to a diverse range of antimicrobial compounds, threatens to halt routine elective implant surgery. One strategy to overcome this problem is to look beyond traditional antimicrobial drug therapies and investigate other treatment modalities. Biophysical modalities, such as ultrasound, are poorly explored, but preliminary work has shown potential benefit, especially when combined with existing antibiotics. Low intensity pulsed ultrasound is already licensed for clinical use in fracture management and thus could be translated quickly into a clinical treatment. Using a methicillin-sensitive S. aureus reference strain and the dissolvable bead assay, biofilms were challenged with gentamicin +/− low-intensity ultrasound (1.5MHz, 30mW/cm2, pulse duration 200µs/1KHz) for 180 minutes and 20 minutes, respectively. The primary outcome measures were colony-forming units/mL (CFU/mL) and the minimum biofilm eradication concentration (MBEC) of gentamicin. The mean number of S. aureus within control biofilms was 1.04 × 109 CFU/mL. Assessment of cellular metabolism was conducted using a liquid-chromatography-mass spectrometry, as well as a triphenyltetrazolium chloride assay coupled with spectrophotometry. There was no clinically or statistically significant (p=0.531) reduction in viable S. aureus following ultrasound therapy alone. The MBEC of gentamicin for this S. aureus strain was 256 mg/L. The MBEC of gentamicin with the addition of ultrasound was reduced to 64mg/L. Metabolic activity of biofilm-associated S. aureus was increased by 25% following ultrasound therapy (p < 0 .0001), with identification of key biosynthetic pathways activated by non-lethal dispersal. Low intensity pulsed ultrasound was associated with a four-fold reduction in the effective biofilm eradication concentration of gentamicin, bringing the MBEC of gentamicin to within clinically achievable concentrations. The mechanism of action was due to partial disruption of the extracellular matrix which led to an increase of nutrient availability and oxygen tension within the biofilm. This metabolic stimulus was responsible for the reversal of gentamicin tolerance in the biofilm-associated S. aureus


Bone & Joint Open
Vol. 3, Issue 11 | Pages 885 - 893
14 Nov 2022
Goshima K Sawaguchi T Horii T Shigemoto K Iwai S

Aims. To evaluate whether low-intensity pulsed ultrasound (LIPUS) accelerates bone healing at osteotomy sites and promotes functional recovery after open-wedge high tibial osteotomy (OWHTO). Methods. Overall, 90 patients who underwent OWHTO without bone grafting were enrolled in this nonrandomized retrospective study, and 45 patients treated with LIPUS were compared with 45 patients without LIPUS treatment in terms of bone healing and functional recovery postoperatively. Clinical evaluations, including the pain visual analogue scale (VAS) and Japanese Orthopaedic Association (JOA) score, were performed preoperatively as well as six weeks and three, six, and 12 months postoperatively. The progression rate of gap filling was evaluated using anteroposterior radiographs at six weeks and three, six, and 12 months postoperatively. Results. The pain VAS and JOA scores significantly improved after OWHTO in both groups. Although the LIPUS group had better pain scores at six weeks and three months postoperatively, there were no significant differences in JOA score between the groups. The lateral hinge united at six weeks postoperatively in 34 (75.6%) knees in the control group and in 33 (73.3%) knees in the LIPUS group. The progression rates of gap filling in the LIPUS group were 8.0%, 15.0%, 27.2%, and 46.0% at six weeks and three, six, and 12 months postoperatively, respectively, whereas in the control group at the same time points they were 7.7%, 15.2%, 26.3%, and 44.0%, respectively. There were no significant differences in the progression rate of gap filling between the groups. Conclusion. The present study demonstrated that LIPUS did not promote bone healing and functional recovery after OWHTO with a locking plate. The routine use of LIPUS after OWHTO was not recommended from the results of our study. Cite this article: Bone Jt Open 2022;3(11):885–893