Advertisement for orthosearch.org.uk
Results 1 - 20 of 149
Results per page:
Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 6 - 6
1 May 2014
Dunbar M
Full Access

There has been a renewed interest in surface replacement arthroplasty over the last decade, with the hope and expectation that this procedure would provide an advantage over conventional total hip arthroplasty, especially in the young, active patient. More specifically, the promises of surface replacement arthroplasty have been: 1) preservation of bone stock so that future revisions would be easier, 2) potential to be minimally invasive in their approach, 3) better functional outcomes because of the stability associated with a larger femoral head with potential associated proprioceptive advantages, and 4) improved survivorship. Unfortunately, these promises have not been realised. Surface replacement arthroplasty does maintain more initial bone stock on the femur, but also tends to remove more bone initially on the acetabular side. Long term, it is the loss of acetabular bone stock that is more problematic from a reconstructive perspective. Further, the “simple” revision afforded in surface replacement arthroplasty has led to reports of inferior clinical outcomes, especially with respect to subjective complaints of pain. Surface replacement arthroplasty is more invasive than conventional total hip arthroplasty as the femoral head is maintained and the window to the acetabulum is subsequently partially blocked. This is exacerbated by the fact that many of these patients are young active males. There is no compelling evidence that surface replacement arthroplasty offers improved functional outcomes over conventional total hip arthroplasty, particularly when considering gait and proprioception. Some studies have in fact shown inferior outcomes. The concept of the larger femoral head in surface replacement arthroplasty providing increased range of motion and subsequent better function is flawed as it is the head-to-neck ratio that appears to be a more important determinant of outcome in this sense. Total hip arthroplasty generally has a more favorable ratio. Surface replacement arthroplasty has inferior survivorship to conventional total hip arthroplasty, even when accounting for the younger age of this patient cohort. This finding is consistent across multiple national joint replacement registries. The outcomes and survivorship are particularly poor in females, with many authors now advocating that the procedure be reserved for males. Surface replacement arthroplasty has introduced several new problems and mechanisms of failures, most concerning of which is the formation of pseudotumors in some patients. It is unclear as to who is at risk for this significant complication, and the ability to diagnose and treat this disorder is difficult and still in evolution. Likely associated is the significant elevation of metal ions in the serum and urine of some surface replacement arthroplasty patients. Neck fractures and loss of bone stock around the femoral implant have also been noted as problematic for these devices. Some of these problems have led to specific surface replacement arthroplasty systems being recalled. Finally, surface replacement arthroplasties are premium products with associated increased costs, which, frankly, are not justified


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_12 | Pages 105 - 105
1 Jul 2014
Su E
Full Access

Surface replacement of the hip was established in the 1970's as a bone preserving alternative to total hip replacement. However, problems with femoral neck fracture, osteolysis, and component loosening led to early failures and an abandonment of the procedure. The modern generation of hip resurfacing, however, has improved upon past results with new implant designs and materials. Better surgical guides and a short femoral stem allows for more accurate placement of the implants. A metal-on-metal articulation creates a larger diameter bearing and avoids polyethylene wear debris. Also paramount in the recent successes of surface replacement are refinements in surgical techniques, leading to more accurate component positioning, avoidance of neck notching, and an appreciation of the femoral head blood supply. The mid-term results of these newer hip resurfacing devices, coupled with appropriate patient selection and good surgical technique, have been encouraging. Although more recently surface replacement has come under fire because of the metal-on-metal articulation, the Australian National Joint Registry finds that a certain group of patients has greater survivorship with resurfacing than with total hip replacement. Therefore, the presenter feels that surface replacement arthroplasty is still a viable option in this subgroup of patients. Additionally, the benefits of surface replacement include the preservation of bone, a lower dislocation rate, and potentially a higher activity level


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 4 - 4
1 Mar 2010
Vendittoli P Lavigne M Roy AG Lusignan D
Full Access

Purpose: Surface replacement arthroplasty is being increasingly offered as the treatment of choice to young and active patients with hip arthritis with proposed advantages including bone conservation and better functional outcome. Excellent outcome has been reported in the few recent short-term clinical series of surface replacement arthroplasty. However they have an inbuilt patient selection bias. There are no direct prospective randomized studies comparing the newer generation of surface replacement arthroplasty with conventional total hip arthroplasty. Our study addresses this issue. Method: 210 hips in 194 patients were randomized to receive either an uncemented total hip arthroplasty or a hybrid metal-on-metal surface replacement arthroplasty. Complications, functional outcomes, along with patient satisfaction and radiographic evaluation were compared at a minimum of two years follow up. Results: Patients in both groups demonstrated a very high satisfaction rate and achieved similar functional scores. Four dislocations occurred in the THA group (one needing acetabular cup revision) and none in the SRA group. There were no femoral neck fractures in the surface replacement arthroplasty group. However, two surface replacement arthroplasty cases underwent revision for late head collapse and one needed a femoral neck osteoplasty for persisting femoro-acetabular impingement. Better biomechanical restoration was attained with surface replacement arthroplasty. All the components were considered to be stable after an average follow up of 45 months. Conclusion: Although surface replacement arthroplasty of the hip offer similar patient satisfaction, functional outcome and complication rate as an uncemented total hip arthroplasty in a young and active group of patients, different complications were associated to each procedure. Better patient selection could avoid some of the complications in the surface replacement arthroplasty group. One main advantage that remains for the surface arthroplasty technique it is the proximal femoral bone stock preservation. However, long term survival analysis is necessary to determine the true advantage of these implants over total hip arthroplasty


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 166 - 166
1 Mar 2010
Jerosch J
Full Access

Introduction: Shoulder surface replacement arthroplasty has been established for several decades as a mean to restore comfort and function of the shoulder for many afflictions that derange the normal anatomy. The surface replacement may offer some advantages over the stemmed prostheses. Purpose: The purpose of the study was to evaluate the clinical and radiological results of Copeland cementless surface replacement arthroplasty (CSRA) applied in patients with bony defects of the humeral head. Patients and Methods: The study was conducted on 18 patients (2 patients with chronic posterior dislocation, 8 patients with AVN, 8 patients with posttraumatic head necrosis) with bony head defects that were operated on between 1999 and 2006. The patients were followed up clinically and radiologically for a mean of 24.8 months (range, 10–78 months). There were 8 female and 10 male shoulders. The mean age was 55.3 years (range, 27–71). The clinical assessment was performed with the Constant score. Results: The constant score significantly improved from a mean of 14.83 points preoperatively to 64.34 points postoperatively. The average pain score increased from 0.3 points to 9.8 points. The average ROM score increased from 8.21 points to 23.21 points. The humeral offset increased from 22.3 mm to 28.8 mm. Conclusion: The shoulder surface replacement arthroplasty shows good mid-term results in patients with bony defects


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 26 - 26
1 May 2013
Su E
Full Access

Surface replacement of the hip has become established as an alternative treatment to total hip replacement in the younger, active, male patient. By the very nature of preserving the femoral head and neck, there may be failures due to femoral neck fracture and femoral component loosening. Additionally, revisions of hip resurfacing for acetabular loosening may be necessary. Other scientific papers have described problems that may arise as a result of the metal-on-metal bearing either due to excess metal production or an immunologic-mediated reaction to the metal debris. Grammatopolous et al. describe poor results of revisions of surface replacements due to massive tissue destruction at the time of revision surgery, persistent pain, and swelling. In my experience with hip resurfacing, this complication is extremely rare. In my series of 925 resurfacings with a minimum of 2 year follow up, 12 revisions (1.3%) have been performed. Of these revisions, only 3 (0.3%) were for complications related to the metal-on-metal bearing; 2 for edge-loading and excess metal production, and 1 for metal hypersensitivity. None of the revision cases have had abductor destruction, or nerve/vascular involvement. Reconstruction of the joint was carried out with standard and revision components; post-operative function of these patients has been comparable to that of a primary total hip replacement. With careful monitoring of the post-operative resurfacing patient, problems can be identified early and surface replacement conversion can be performed with excellent results


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 121 - 121
1 Mar 2010
Jerosch J
Full Access

Introduction: Glenohumeral arthritis with a massive rotator cuff tear is a devastating condition that seriously compromises the comfort and function of the shoulder. Cuff tear arthropathy presents a unique surgical challenge and many arthroplasty options were used for its treatment. The purpose of this study was to evaluate the clinical and radiological results of Copeland cementless surface replacement arthroplasty (CSRA) applied in patients with cuff tear arthropathy and intact subscapularis function. Patients and Methods: The study was conducted on twenty five shoulders in twenty five patients with cuff tear arthropathy with the subscapularis tendon still intact. The patients were prospectively followed up clinically and radiologically for a mean of 26 months (range, 15–38 months). There were 16 female and 9 male shoulders. The mean age was 69.04 years (range,53–83years). The mean operative time was 38 minutes (range, 28–56minutes). The clinical assessment was performed with the Constant score. Results: The constant score significantly improved from a mean of 14.04 points preoperatively to 53.17 points postoperatively. Of the patients, 88% considered the shoulder to be much better or better as a result of the operation. Radiologically, the humeral offset, the lateral gleno-humeral offset (coracoid base to the greater tuberosity), height of center of instant rotation and the acromio-humeral distance were significantly increased. No intra-or postoperative complications encountered. Conclusion: Our early results with the use of Copeland surface replacement in selected cases with cuff tear arthropathy were encouraging. The patients showed significant clinical (pain and range of motion) and radiological improvements. Moreover, if the surface replacement were to fail for any reason, it can be revised to a reverse prosthesis type as there is no lack of bone stock


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 99 - 99
1 Jan 2004
Funk L Koury E Levy O Copeland S
Full Access

Avascular necrosis (AVN) of the humeral head is an extremely disabling condition (Gerber et al, JSES 1998. 7(6):586–90). The results of stemmed arthroplasty for this condition are good, with Hattrup and Cofield reporting 79% subjective improvement at nine years (JSES 2000;9:177–82). This study reports the outcomes of surface replacement shoulder arthroplasties for AVN over a 16 year period. Between 1986 and 2001 twenty-seven arthroplasties were performed in patients with advanced avascular necrosis of the humeral head. All patients had secondary degenerative changes. AVN was secondary to corticosteriods and trauma in most cases. The mean age of the patients was 60 years (range 35 to 86). These included 16 hemiarthroplasties and 7 total shoulder arthroplasties. All prostheses were of the Copeland Surface Replacement Arthroplasty (CSRA) type. The average follow up period was 6 years (range 1 to 13). The average preoperative Constant score was 17. This improved to 74 at follow-up. Forward flexion improved from 63 degrees preoperatively to 133 degrees at follow-up. Abduction improved from 49 degrees to 118 degrees. External rotation improved from −3 degrees to 61 degrees. Pain scores improved from 0 to 11.7, using a 15 point visual analogue scale. 81% of patients had slight and no difficulty performing their routine activities of daily living. The remaining 19% still had some difficulty with routine activities. Four of the patients performed regular overhead activity and recorded some difficulty in doing this, whereas they had great difficulty pre-operatively. There were no cases of loosening. No difference was seen in any of the results between the hemi-arthroplasty and total shoulder replacement patients. Surface replacement arthroplasty is a suitable procedure for degenerative disease secondary to AVN of the humeral head, with results similar to stemmed prostheses. It has the advantage of preserving bone stock


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 26 - 26
1 Mar 2008
Thomas S Wilson A Chambler A Harding I Thomas M
Full Access

The Copeland Shoulder Arthroplasty is a cementless, pegged humeral head surface replacement. The design is based on the principle of minimal bone resection and has been in clinical use since 1986. The only published series to date, that of Levy and Copeland, reported results for 103 patients which were comparable to those obtained with stemmed implants. We report the outcome at our institution using the same prosthesis with a hydroxyapatite coating. 81 shoulders (74 patients) underwent resurfacing hemiarthroplasty through an anterior deltopectoral approach. Preoperative diagnoses were: osteoarthritis (39), rheumatoid arthritis (29), rotator cuff arthropathy (1), post-traumatic arthrosis (2). They were followed for an average 28 months. 10 were lost to follow-up (8 deaths). Constant scores improved from a mean preoperative figure of 15.7 to 54.0 (p< 0.01) at last follow-up. For rheumatoid arthritis and osteoarthritis the scores improved from 15.2 to 50.4 (p< 0.01) and 16.0 to 55.4 (p,< 0.01) respectively. There was a 13% complication rate with one case requiring revision for loosening to a stemmed implant. Most were cases requiring subsequent acromioplasty. In one case the glenoid rim was fractured during head dislocation. There was a low rate of perioprosthetic radiolucency (4.2%) which may relate to the hydroxyappatite coating within the shell of the prosthesis. Ipsilateral stemmed elbow replacement was performed in some cases without a double stress riser effect. Periprosthetic humeral neck fracture as managed non-operatively with uneventful union. Conclusion: The good outcome reported in Copeland’s own series has been replicated in the early to medium term at our institution. The surface replacement system is simpler, accurate and preserves bone stock


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 171 - 172
1 May 2011
Johanson P Fenstad A Furnes O Garellick G Havelin L Herberts P Overgaard S Pedersen A Kärrholm J
Full Access

Introduction: There is an increasing interest in surface replacement arthroplasty (SRA) as an alternative to conventional THA (cTHA) in young and active patients. However, there has been considerable variability in reported outcomes. National joint registry reports have shown increased revision rates compared to cTHA. We analysed outcome measured as non-septic revision rate within two years for SRA in the NARA data base (Nordic Arthroplasty Register Association). Materials and Methods: 1638 SRA and 163802 cTHA with age up to 73 years and a non-fracture diagnosis, operated from 1995 to 2007, were compared using Cox multiple regression including age, gender, diagnosis, nation and prosthesis type with cTHA divided into cemented, uncemented, hybrid and reversed hybrid fixation. Men below 50 years of age (460 SRA and 7185 cTHA) were analysed as a subset. The SRA cohort with a mean follow-up 1,8 years was also analysed with the same method including age, gender, diagnosis, number of performed SRA per hospital and the four most commonly used prosthesis designs. In an additional analysis femoral head diameter was added, reducing the number of cases to 1552. results are presented as relative risk (RR) with 95 % confidence interval(CI). Results: SRA had a more than twofold increased revision risk compared to cTHA, RR=2,50 (1,67–3,70), which increased to 3,63 (2,42–5,44) when compared with all cemented THA. In the subpopulation of men below 50 years of age, there was no difference between SRA and any of the cTHA cathegories. Within the SRA group RR was reduced by male gender, RR=0,46 (0,25–0,86), in hospital performing > 70 SRA (RR=0,26, 0,11–0,60) and with use of BHR (Birmingham Hip Resurfacing) compared to all other designs (RR=0,27, 0,12–0,61). The size of the femoral head diameter had no significant influence on the early revision rate. Discussion and Conclusion: Surface replacement arthroplasty has an increased risk of early revision compared to conventional and cemented THA except for men below 50 years of age. There is a learning curve on the hospital level. Cases with secondary osteoarthritis were comparatively few and were mainly caused by pediatric hip disease. SRA might become an alternative for young men, but our follow up is too short to determine if this indication remains in the longer perspective


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 38 - 38
1 Mar 2009
Fuerst M Rüther W
Full Access

Introduction: Rheumatoid arthritis often leads to severe destruction of the glenohumeral joint including synovitis and inflammation induced alterations of the rotator cuff. Cup arthroplasty, or surface replacement of the shoulder was introduced in the 1980s. The aim of this study was to confirm or withdraw the very promising results of the DUROM-Cup surface replacement for patients with rheumatoid arthritis. Patients an Methods: From 1997 to 2000 a cohort of 42 DUROM-Cup hemiprotheses were implanted in 35 patients. The patients were evaluated preoperatively and after 3,12 and more than 60 month postoperatively. 7 patients were lost to follow up. A total of 35 DUROM-Cups (29 patients) could be examined prospectively after an average follow up period of 73.1 (+/− 12.1) month (Average age 61.4y, female n=21, male n=68). Rotator cuff defects were classified intraoperatively. Results: Three revisions occured: One due to a too large implant, one due to glenoid erosion and one due to loosening of the implant. The constant score increased from preoperatively 20.8 points to 64.3 points at a mean follow up of 73.1 month. No differences were seen in patients with massive cuff tears. In these cases the cup was implanted in a more valgic position, so that articulation with the acromion could be achieved. The radiographic results did not show any changing of the parameters for the position of the cup. No further endo-prosthetic loosening was observed. The proximal migration increased in 66% and the glenoid depht increased in 37% of the cups. Discussion: The results of the cemented DUROM-Cup surface replacement for patients with advanced rheumatoid arthritis of the shoulder are very encouraging, especially in patients with massive tearing of the rotator cuff. The advantages of cup arthroplasty are to be found in the reduced level of invasive surgery and the simpler technique with bone saving fixation. In the event of failure of the implant good further treatment options for salvage procedures remain


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 346 - 346
1 May 2006
Levy O Raj D Copeland S
Full Access

Copeland Surface replacement arthroplasty provides a good outcome in cases of arthritis. However, the limitation of use of this prosthesis is severe bone loss of the humeral head. We describe the use of Copeland Surface Replacement Shoulder Arthroplasty in cases of severe humeral head destruction extending more than 50% of the humeral head. The bone deficiency was reconstructed with the autograft from the reaming and reshaping of the humeral head and a synthetic bone graft substitute (Tricalcium phosphate granules (Biosorb)) mixed with the patient’s blood. We report preliminary results in 8 cases. 3 males and 4 females (One patient bilateral). The average age was 48 years ( 22–76 years). 5 cases had Posttraumatic avascular necrosis of humeral head, two patients had locked posterior fracture dislocation with loss of more than 50% of the humeral head and one patient with severe juvenile rheumatoid arthritis. In this series the remaining bone of humeral head was less than 50% ranging between 30–50% (average 38%). The patients were followed clinically and radiographically. The average follow–up was 10.6 months (range: 5 to 15 months). All patients had substantial improvement in there shoulder function and pain. All the patients were very satisfied. Average pre-op constant score was 9.3 points (range: 9–14). At the latest follow-up the average constant score was 59 (range: 36–74). Age and sex adjusted constant score was 68.6 (range: 37– 87). Radiographically we observed good incorporation of the Bone graft substitute with no signs of loosening or any lucencies under the prosthesis. These are early and encouraging results in this group of young patients with severe destruction of the humeral head. It seems like it may provide a good bone preserving solution in these cases and extend the frontiers for the surface replacement of the shoulder


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_12 | Pages 1 - 1
1 Jul 2014
Krishnan S
Full Access

The classic Hill-Sachs lesion is a compression or impression fracture of the humeral head in occurrence with anterior glenohumeral instability. The true incidence is unknown but clearly increases with recurrent instability episodes. Recent peer-reviewed literature has highlighted the importance of addressing “significant” humeral and glenoid bone defects in the management of glenohumeral instability. Quantification of the “significance” of a Hill-Sachs lesion with regard to location, size, and depth in relation to the glenoid has helped guide indications for surgical management. Options for managing Hill-Sachs lesions include both humeral-sided techniques (soft tissue, bone, and/or prosthetic techniques) and also glenoid-sided techniques (bone transfers to increase glenoid width). The majority of significant acute or chronic Hill-Sachs lesions can be effectively managed without prosthetic replacement. Is a prosthetic surface replacement ever indicated for the management of Hill-Sachs lesions? The peer-reviewed literature is sparse with the outcomes of this treatment, and significant consideration must be given to both the age of the patient and the need for such management when other effective non-prosthetic options exist. In a patient with more than half of the humeral head involved after instability episodes (perhaps seizure or polytrauma patients), metallic surface replacement arthroplasty may be an option that could require less involved post-operative care while restoring range of motion and stability


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 230 - 230
1 Sep 2005
Ganapathi M Evans S Roberts P
Full Access

Introduction: Surface replacement of the hip has been proposed as an alternative to total hip replacement, particularly in young active patients. The suggested benefits include preservation of bone stock for future revision surgery and avoidance of proximal femoral stress protection, which can cause bone resorption. However, following femoral head resurfacing, femoral neck fracture can occur. The aim of this study was to compare the strain pattern in intact and resurfaced femurs using validated third generation composite femurs and rosette strain gauges. Methods: Rosette strain gauges were applied to an intact and a resurfaced third generation composite femur at three sites; narrowest part of the lateral surface of the neck, narrowest part of the medial surface of the neck and medial surface at the level of lesser trochanter. The femurs were loaded with axial loads of 600N, 800N and 1000N sequentially. The tests were repeated thrice for each femur. Maximum and minimum principal strains were calculated. Further tests were carried out in which an abductor load was included in the model. Testing was done at 600N and repeated thrice for each femur. The principal strains were calculated and compared with the the principal strains without the abductor load. Results: The maximum principal strains in the resurfaced femur were approximately 50% higher in the lateral surface of the neck and about 30% higher in the lesser trochanteric region when loaded without including an abductor force. Inclusion of the abductor force decreased the strain particularly at the lateral surface of the neck by approximately 45% in the intact femur and approximately 25% in the implanted femur. Even with the inclusion of the abductor load the strain in the resurfaced femur remained more than 50% higher at the lateral surface of the neck and 20% higher in the lesser trochanteric region. Conclusion: Our study suggests that proximal femoral stress protection will not occur following surface replacement of the hip. The increased strain at the lateral surface of the neck could result in fracture, particularly if there is notching of the neck or if abductor function has been compromised, which can happen particularly with the direct lateral approach


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 206 - 206
1 Mar 2010
Lee KT Bell S Salmon J
Full Access

Biologic resurfacing of the glenoid combined with surface replacement hemiarthroplasty for relatively young patients suffering from advanced glenohumeral arthritis has the advantages of both humeral head and glenoid bone preservation. The longer term results of this procedure are reported. Twenty two shoulders in 21 patients had a surface replacement hemiarthroplasty with resurfacing of the glenoid with the anterior capsule. At follow up one had died, and another was not contactable. The prosthesis was removed in one for deep infection, and the fourth patient had undergone revision to a total shoulder arthroplasty for ongoing pain. Therefore, 17 patients with 18 operated shoulders were available for clinical assessment. The average age of the patients was 54.8 years (35–78) at the time of surgery. The average length of follow-up was 4.8 years (2–10.6). The average Constant Score was 71.4 points (41–95), and the sex- and age-adjusted Constant Score was 83.9%. The mean ASES score was 74.4 points (35–100). The average arc of forward flexion was 130 degrees (100–160), and external rotation was 39 degrees (20–60). On a VAS scale of 0 to 10, the average pain score at rest was 0.5 (0–3), while pain with activity was 2.4 (0–6). Sixteen of the 17 patients (94%) had a satisfactory result, and would have the operation again. Eight of the 17 patients (47%) were able to return to their previous sporting activities. Radiographic follow-up demonstrated there were 2 mild and 2 moderate cases of superior subluxation of the humeral head. There was no subsidence or signs of loosening of any humeral prosthesis. The average glenohumeral joint space was 0.13mm (0–2). Glenoid erosion was none in one case, mild in 6 cases, moderate in 6 cases, and severe in 3 shoulders. Although the results of this procedure compare favourably with other series, the extent of glenoid erosion is concerning. A more robust tissue for interposition may give better results


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 36 - 36
1 Jun 2018
Barrack R
Full Access

Total hip arthroplasty (THA) is among the most successful interventions in all of medicine and has recently been termed “The Operation of the Century”. Charnley originally stated that “Objectives must be reasonable. Neither surgeons nor engineers will ever make an artificial hip joint that will last 30 years and at some time in this period enable the patient to play football.” and he defined an appropriate patient as generally being over 65 years of age. Hip rating scales developed during this time were consistent with this approach and only required relief of pain and return to normal activities of daily living to achieve a perfect score. Since this time, however, hip arthroplasty has been applied to high numbers of younger, more active individuals and patient expectations have increased. One recent study showed that in spite of a good hip score, only 43% of patients had all of their expectations completely fulfilled following THA. The current generation metal-metal hip surface replacement arthroplasty (SRA) has been suggested as an alternative to standard THA which may offer advantages to patients including retention of more native bone, less stress shielding, less thigh pain due to absence of a stem, less limb length discrepancy, and a higher activity level. A recent technology review by the AAOS determined that currently available literature was inadequate to verify any of these suggested potential benefits. The potential complications associated with SRA have been well documented recently. The indications are narrower, the implant is more expensive, the technique is more demanding and less forgiving, and the results are both highly product and surgeon specific. Unless a clinical advantage in the level of function of SRA over THA can be demonstrated, continued enthusiasm for this technique is hard to justify. To generate data on the level of function of younger more active arthroplasty patients, a national multicenter survey was conducted by an independent university medical interviewing center with a long track record of conducting state and federal medical surveys. All patients were under 60, high demand (pre-morbid UCLA score > 6) and had received a cementless stem with an advanced bearing surface or an SRA at one of five major total joint centers throughout the country. The detailed questionnaire quantified symptoms and function related to employment, recreation, and sexual function. Patients with SRA had a higher incidence of noises emanating from the hip than other bearing surfaces although this was transient and asymptomatic. SRA patients were much more likely to have less thigh pain than THA, less likely to limp, less likely to perceive a limb length difference, more likely to run for exercise, and more likely to run longer distances. In another study of over 400 THA and SRA patients at two major academic centers, patients completed pain drawings that revealed an equivalent incidence of groin pain between THA and SRA, but an incidence of thigh pain in THA that was three times higher than in SRA in young active patients. While some or most of the observed advantages of SRA over THA may be attributable to some degree of selection bias, the inescapable conclusion is that SRA patients are demonstrating clinical advantages that warrants continued utilization and investigation of this procedure


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 75 - 75
1 Aug 2017
Barrack R
Full Access

Total hip arthroplasty is among the most successful interventions in all of medicine and has recently been termed “The Operation of the Century”. Charnley originally stated that “Objectives must be reasonable. Neither surgeons nor engineers will ever make an artificial hip joint that will last 30 years and at some time in this period enable the patient to play football.” and he defined appropriate patient as generally being over 65 years of age. Hip rating scales developed during this time were consistent with this approach and only required relief of pain and return to normal activities of daily living to achieve a perfect score. Since this time, however, hip arthroplasty has been applied to high numbers of younger, more active individuals and patient expectations have increased. One recent study showed that in spite of a good hip score, only 43% of patients had all of their expectations completely fulfilled following THA. The current generation metal-metal hip surface replacement arthroplasty (SRA) has been suggested as an alternative to standard THA which may offer advantages to patients including retention of more native bone, less stress shielding, less thigh pain due to absence of a stem, less limb length discrepancy, and a higher activity level. A recent technology review by the AAOS determined that currently available literature was inadequate to verify any of these suggested potential benefits. The potential complications associated with SRA have been well documented recently. The indications are narrower, the implant is more expensive, the technique is more demanding and less forgiving, and the results are both highly product and surgeon specific. Unless a clinical advantage in the level of function of SRA over THA can be demonstrated, continued enthusiasm for this technique is hard to justify. To generate data on the level of function of younger more active arthroplasty patients, a national multicenter survey was conducted by an independent university medical interviewing center with a long track record of conducting state and federal medical surveys. All patients were under 60, high demand (pre-morbid UCLA score > 6) and had received a cementless stem with an advanced bearing surface or an SRA at one of five major total joint centers throughout the country. The detailed questionnaire quantified symptoms and function related to employment, recreation, and sexual function. Patients with SRA had a higher incidence of noises emanating from the hip than other bearing surfaces although this was transient and asymptomatic. SRA patients were much more likely to have less thigh pain than THA, less likely to limp, less likely to perceive a limb length difference, more likely to run for exercise, and more likely to run longer distances. In another study of over 400 THA and SRA patients at two major academic centers, patients completed pain drawings that revealed an equivalent incidence of groin pain between THA and SRA, but an incidence of thigh pain in THA that was three times higher than in SRA in young active patients. While some or most of the observed advantages of SRA over THA may be attributable to some degree of selection bias, the inescapable conclusion is that SRA patients are demonstrating clinical advantages that warrants continued utilisation and investigation of this procedure


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 247 - 247
1 Jul 2011
Antoniou J Mwale F Zukor DJ Huk OL Petit A
Full Access

Purpose: The presence of metal ions in the blood of patients with a metal-on-metal (MM) bearing points to the importance of understanding the long-term effects of these ions. Metal ions have the potential to induce the production of reactive oxygen species (ROS), making them prime suspects for inducing molecular damage in circulating cells. The aim of this study was to analyze the levels of oxidative stress markers in the plasma of patients with hip surface replacement. Method: Blood was collected up to 3 years after implantation from 66 patients with articular surface replacement (ASRÔ, DePuy Orthopaedics) and 54 patients with 36 mm-head MM THA. Forty (40) pre-operative patients were also assessed as control group. Total anti-oxidant levels were measured by the Oxford Biomedical total antioxidant power assay (Oxford, MI) to obtain an overview of the defense capacity of patient’s oxidative stress. Peroxide concentrations were measured by the Biomedica OxyStat assay (Medicorp, Montreal, QC) to quantify damage to lipids in the systemic circulation. Nitrototyrosine levels were quantified using the BIOXYTECH® Nitrotyrosine-EIA assay (OxisResearch™, Portland OR) to measure damage to proteins. The concentrations of metal ions were analyzed by inductively coupled plasma-mass spectroscopy. Results: Results showed that there were no statistical differences in the concentrations of total antioxidants, lipid peroxides, and protein nitrotyrosines between the control, the ASR, and the 36 mm-head groups. Furthermore, there was no correlation between the concentrations of these markers and the concentrations of both Co and Cr ions (r2 £ 0.006). Conclusion: The single most significant obstacle preventing a broader application of metal-on-metal hip arthroplasties and resurfacings continues to be the concerns regarding elevated metal ion levels in the blood and urine of patients. The present results showed that there were no changes in the levels of oxidative stress markers in patients with MM bearings compared to the control group. Given the possible latency periods related to metal ion exposure, longer follow-ups are required to conclusively determine the effects of elevated circulating ions on oxidative stress in the blood of patients with MM bearings


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 66 - 66
1 Jan 2011
Ziaee H Daniel J Pradhan C Pynsent P McMinn D
Full Access

Introduction: Metal-metal (MM) surface replacement arthroplasty of the hip is showing promise as an effective and enduring solution in the management of hip arthritis in the young, and is being increasingly used. The main concern is the release of metal ions into the systemic circulation and their long-term effects. There is concern that metal ions cross the placenta in pregnant women with MM bearing arthroplasties with the potential for mutagenic effects in the offspring. The hypothesis is that metal ions pass freely through the placenta and that there is no difference in the maternal and cord metal ion levels. Methods: This is a controlled cross-sectional study of women of child-bearing age with MM bearing surface replacement arthroplasties. (n= 25, mean age: 32 years, mean duration after resurfacing 60.3 months, 3 bilateral). The control group consisted of 24 subjects who do not have a metallic implant, were not taking any supplements containing cobalt or chromium salts and were registered to undergo an elective LSCS at the regional hospital. Mean age of the control group was 31.3 years. No patient in either group was known to have renal failure. Whole blood specimens were obtained from the mothers just before delivery and before infusion of any fluids, and cord blood specimens were obtained immediately after delivery. High resolution inductively couples mass spectrometry (HRICPMS) was used for metal ion analysis. Results: Cobalt and chromium were detectable in all specimens in both the study patients and controls. In the study group, mean cord metal ion levels were significantly lower than the maternal cobalt (p < 0.05) and chromium (p < 0.0001) levels thus rejecting the null hypothesis. In the control group, the mean difference between maternal and cord metal ion levels was only 5 to 7% and was statistically not significant (p > 0.5). The mean difference in cord chromium between the study and control groups is not statistically significant (p > 0.05), although cord cobalt in the study group is significantly higher (p < 0.01) than that in controls. Whilst there is a four-fold elevation of maternal cobalt in the study patients and an almost 7-fold increase in maternal chromium levels as compared to the control group, the elevation in the cord cobalt and chromium in the study group are smaller. Discussion and Conclusion: The differences between maternal and cord metal ions in the control patients indicate that normally the placenta allows an almost free passage of metal ions. This is understandable when we realize that these elements are also required by the developing foetus for its cellular and metabolic functions. The relative levels of metal ions in the maternal and cord blood in the study group patients reveal that the placenta does exert a modulatory effect on metal transfer. The mean cord levels of cobalt and chromium in these patients are only 57% and 24% of the maternal blood levels respectively. There is a continuing need for efforts to reduce metal ion release from artificial joints and also to monitor metal ion levels in patients with MM devices


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 1 - 1
1 Nov 2015
Burkhead W
Full Access

Hill-Sachs and reverse Hill-Sachs lesions come in different shapes and sizes, and their effect on “glenoid track” can vary. Small Hill-Sachs lesions that do not engage can be successfully treated with a Bankart repair alone done arthroscopically or open. Moderate, engaging, Hill-Sachs lesions can be treated either with the addition of remplissage to an arthroscopic Bankart or by adding the triple blocking effect of the Bristow-Latarjet procedure. Surface replacements vary in size from the small hemi-cap type of procedure to an entire humeral head replacement (HHR). These devices can be used as opposed to allograft replacement when the risk of post-reconstruction arthritis is high with the aforementioned more conventional treatment techniques. When 45% or more of the humeral head is involved with the lesion, or Outerbridge stage III and IV changes prevail, a HHR is preferred. An oval shaped HHR is the author's preference, and the long diameter can be used to provide coverage anteriorly or posteriorly and is particularly useful in large Hill-Sachs lesions associated with epilepsy


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 101 - 101
1 May 2016
Ziaee H Daniel J McMinn D
Full Access

Metal-metal surface replacement (MoMSRA) is increasingly used in the young. Systemic metal ion release and its effects cause concern. Do metal ions cross the placenta in pregnant women with potential mutagenic effects? The hypothesis is that metal ions pass freely through the placenta and there is no difference in maternal and cord metal levels. This is a controlled cross-sectional study of women with MoMSRA. (n=25, mean age 32years, implantation 60months, 3 bilateral). The control group were 24 subjects with no metallic implant and not receiving cobalt/chromium supplements, mean age 31years. No patient was known to have renal failure. Whole blood specimens were obtained before delivery/ fluid-infusion and Cord blood specimens immediately after delivery. Cobalt and chromium were detectable in all specimens in both cohorts. In the control group, the difference between maternal and cord levels was only 5 to 7% indicating free passage. Study group cord levels were significantly lower than maternal cobalt, p<0.05 and chromium p<0.0001 thus rejecting the null hypothesis. The differences between maternal and cord metal ions in the controls indicate that normally the placenta allows an almost free passage of metal ions. The relative levels of metal ions in the maternal and cord blood in the study group reveal that the placenta exerts a modulatory effect on metal transfer