Aims. This study aimed to determine the minimal detectable change (MDC), minimal clinically important difference (MCID), and substantial clinical benefit (SCB) under distribution- and anchor-based methods for the
Purpose. Evaluation of our experience on the treatment of comminuted, radial head fractures, and of the outcomes of pyrocarbon prosthetic replacement in such cases. Materials and Methods. We evaluated 47 cases of prosthetic replacement, performed from May 2003 to July 2008. There were 18 males and 29 females with an average follow-up of 48 months (12 to 60). The Hotchkiss classification was used to characterize the fractures. The indicators for the procedure were type III fractures in 27 cases, type IV fractures in 10 cases, comminuted radial head fractures (associated with disruption in medial collateral ligament) in 3 cases, Monteggia variant in 5 cases, and Essex Lopresti in 2 cases. Functional outcomes were assessed using the
Aim: As the shoulder and elbow joints share a common objective – spatial positioning of the hand – can the Modified Constant Score of shoulder function be applied to function at the elbow?. Method &
Results: All patients with isolated elbow pathology over an eighteen-month period were assessed. Acute fractures and patients with shoulder and/or wrist pathology were excluded. Upper limb function was assessed using the Modified Constant Score and the
Background. The optimal treatment for symptomatic elbow osteoarthritis remains debatable especially in patients still involved in heavy manual work. The Outerbridge-Kashiwagi (OK) procedure has been used when simple measures fail. The aim of this study is to analyse the results of the OK procedure in patients with symptomatic osteoarthritis. Methods. Twenty-two patients were included in the study. The male:female ratio was 18:4. The mean age was 60 years with mean follow-up of 38 months (24–60 months). 17 were manual workers, 3 involved in sports activities and 2 non-manual workers. All patients were assessed using
This study assesses the clinical performance of the Souter-Strathclyde elbow arthroplasty with a standardised index and long term survivorship analysis. We undertook assessment of 68 primary Souter-Strathclyde total elbow replacements. Of 53 patients assessed with pre-operative Souter-Strathclyde charts, nine died and one was lost to follow-up, 43 had radiographic and telephone review, and 38 (88%) had clinical examination according to the
This study assesses the clinical performance of the Souter-Strathclyde elbow arthroplasty with a standardised index and long-term survivorship analysis. We undertook assessment of 68 primary Souter-Strathclyde total elbow replacements. Of 53 patients assessed with pre-operative Souter-Strathclyde charts, nine died and one was lost to follow-up, 43 had radiographic and telephone review, and 38 (88%) had clinical examination according to the
New concepts in plate fixation have led to an evolution in plate design for olecranon fractures. The purpose of this study was. to compare the stiffness and strength of a contoured Locking Compression Plate (LCP) with a conventional plating method (one-third tubular plate) in a cadaveric comminuted olecranon fracture model with standardized osteotomy, and. to evaluate the LCP fixation method in a prospectively included group of patients with complex olecranon fractures using validated outcome scores. In the biomechanical study, five matched pairs of cadaveric elbows were randomly assigned for fixation by either LCP or a conventional plating method. Specimens were mounted to a custom-made testing bench and subjected to cyclic loading until failure occurred while measuring gapping at the osteotomy site. In the clinical study, twenty-one patients treated with LCP for complex olecranon fractures had a mean follow up of 20 months (3–39 months) and functional and patient rated outcome were evaluated. In the biomechanical study, there was no significant difference in fixation stiffness and strength between one third tubular plating and LCP (p >
0.05). In the clinical study, the mean time to union of the fracture was 6 months (2–28 months). According to the
To evaluate the results of open reduction in unreduced posterior dislocation of the elbow, done irrespective of the time since injury or age of the patient. Ten such cases in which the dislocation had been unreduced for more than 3 weeks since injury were included. Stiffness of the elbow was the main indication for the operation. Average age of the patient was 34.3 years (range 13 years to 65 years). Average time since injury was 3.9 months (range 2 month to 6 months). 3 patients had associated fractures around the elbow joint. All the patients had non functional elbow motion to perform any activity of daily living. We used speed’s procedure in all cases. At an average follow up of 18.5 months (range from 11 to 28 months), 8 patients achieved functional range of motion for activities of daily living and maintained an average arc of flexion(median) of 100 degrees and an average supination – pronation arc of 139.5 degrees. According to the
Previous studies have demonstrated the benefits of arthroscopic arthrolysis in relieving pain and improving motion in arthritic elbows, but none have reported the specific functional recovery. This study aims to review the functional outcome and patient satisfaction in a series of patients who underwent arthroscopic elbow arthrolysis for intrinsic stiffness, pain and arthritis not suitable for arthroplasty. Twenty six patients who underwent arthroscopic arthrolysis over a three year period were included. All patients were manual workers or strength athletes. All had pain and stiffness secondary to primary or secondary arthritis, with or without loose bodies. Pre- and post-operative evaluation included the Elbow Functional Assessment score, patient satisfaction and return to work and sports. The mean follow up period was 22 months. Function improved significantly in 87% with overall improvement in the Elbow Functional Assessment score from a preoperative score of 48 to a postoperative score of 84 (p<
0.05). All except three patients returned to their desired level of activity by 3 months postoperatively. Pain improved in 91%, mechanical symptoms in 80%, stiffness in all except one. The arc of elbow movement improved from 106° to 124° with a mean gain in elbow extension of 13°.
Background. Comminuted radial head fractures are challenging to treat with open reduction and internal fixation. Complicating matters further, radial head fractures are often associated with other elbow fractures and soft tissue injuries. Radial head arthroplasty is a favorable technique for the treatment of radial head fractures. The purpose of this study was to evaluate the functional outcomes of radial head arthroplasty using Modular Pyrocarbon radial head prosthesis in patients with unreconstructible radial head fractures. Methods. This single surgeon, single centre study retrospectively reviewed the functional and radiological outcomes of 21 consecutive patients requiring radial head arthroplasty for unreconstructible radial head fractures between July 2003 and July 2009. Patients were at least one year post-op and completed a Short-Form 36 (SF-36) questionnaire, the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire, and the
The purpose of this study was to demonstrate the beneficial effects of elbow arthrolysis. This was a prospective study on 88 patients with post-traumatic elbow stiffness with a mean follow-up of 51 months (1 year - 11 years), who had failed to improve their range of movement at a mimimum period of 6 months after their injury. All patients had an open arthrolysis. Post-operatively patients received continuous passive movement (CPM) for 48 to 72 hours. This was facilitated by good analgesia afforded by a continuous brachial plexus block. All patients received no physiotherapy thereafter and were advised to actively mobilise their elbow. ROM was assessed using a goniometer and function assessed using the
Introduction. The action of the radial head in the stability of the elbow is currently admitted. Its conservation is not always possible in complex fractures. The association with a posterolateral dislocation of the elbow leads to a higher risk of instability of the elbow joint and also at a longer term to degenerative changes. Some authors recommend the use of metallic radial head implant, acting as a spacer. The results seems encouraging but should the resection arthroplasty associated with the repair of the medial collateral ligament be abandoned?. Material and methods. In an amount of 35 consecutive patients who were taken in charge for an elbow dislocation 26 were included in this retrospective study, 13 of them had the association of a dislocation and a fracture of the radial head. In all 13 cases the radial head was considered as inadequate with a conservative treatment and was resected. The patients were assessed clinically according to the American Shoulder and Elbow Surgeons score (ASES) and the
Purpose: This study reviews the early results of elbow hemiarthroplasty for distal humeral fractures. Method: Elbow hemiarthroplasty was performed on 30 patients (mean 65 years; 29–91) for unreconstruc-table fractures of the distal humerus or salvage of failed internal fixation. A ‘triceps on’ approach was used in six and an olecranon osteotomy in 24. A Sorbie Questor prosthesis (Wright Medical Technology) was used in 14 patients and a Lattitude (Tornier) in 16. Clinical review at a mean of 25 months (3–88) included the American Shoulder and Elbow Surgeons elbow outcomes instrument (ASES),
This study reviews the early results of elbow hemiarthroplasty for distal humeral fracture. Elbow hemiarthroplasty was performed on 30 patients (mean 65 years; 29–91) for unreconstructable fractures of the distal humerus or salvage of failed internal fixation. A ‘triceps on’ approach was used in 6 and an olecranon osteotomy in 24. A Sorbie Questor prosthesis (Wright Medical Technology) was used in 14 patients and a Lattitude (Tornier) in 16. Clinical review at a mean of 25 months (3 – 88) included the American Shoulder and Elbow Surgeons elbow outcomes instrument (ASES),
This study reviews the early results of Distal Humeral Hemiarthroplasty(DHH) for distal humeral fracture and proposed a treatment algorithm incorporating the use of this technique in the overall management of distal humeral fractures. DHH was performed on 30 patients (mean 65 years; 29-91) for unreconstructable fractures of the distal humerus or salvage of failed internal fixation. A triceps on approach was used in six and an olecranon osteotomy in 24. A Sorbie Questor prosthesis (Wright Medical Technology) was used in 14 patients and a Latitude (Tornier) in 16. Clinical review at a mean of 25 months (3–88) included the American Shoulder and Elbow Surgeons elbow outcomes instrument (ASES),
Purpose: To review the clinical outcome of patients who have had complex radial head fractures managed with titanium radial head replacement. Methods: There were 17 patients who had insertion of the radial head replacement. The indications for the prosthesis included acute Mason type III fracture which could not be stabilised satisfactorily with internal fixation. Other indications included delayed presentation including previously failed treatment. Patients were managed with radial head excision and insertion of the Wright Medical titanium radial head replacement. The lateral ligamentous complex was stabilised. A back slab was applied for a period of one week and then the elbow mobilised. The patients were followed up for a minimum of one year. The
This cohort study reports outcomes of patients with comminuted radial head fractures treated with a modular radial head arthroplasty. Twenty-six patients (mean age = fifty-four) were prospectively followed at three, six, twelve, and twenty-four months following surgery. Patient satisfaction with this procedure was high. This data indicates favorable results using a modular radial head arthroplasty with rapid improvement in disability and physical impairment occurring in all measures in the first six months and further improvement in most patients up to two years. The
Post-traumatic elbow stiffness is a disabling condition that remains challenging for upper limb surgeons. Open elbow arthrolysis is commonly used for the treatment of stiff elbow when conservative therapy has failed. Multiple questions commonly arise from surgeons who deal with this disease. These include whether the patient has post-traumatic stiff elbow, how to evaluate the problem, when surgery is appropriate, how to perform an excellent arthrolysis, what the optimal postoperative rehabilitation is, and how to prevent or reduce the incidence of complications. Following these questions, this review provides an update and overview of post-traumatic elbow stiffness with respect to the diagnosis, preoperative evaluation, arthrolysis strategies, postoperative rehabilitation, and prevention of complications, aiming to provide a complete diagnosis and treatment path. Cite this article:
The aim of this study was to report the mid-term clinical outcome
of cemented unlinked J-alumina ceramic elbow (JACE) arthroplasties
when used in patients with rheumatoid arthritis (RA). We retrospectively reviewed 87 elbows, in 75 patients with RA,
which was replaced using a cemented JACE total elbow arthroplasty
(TEA) between August 2003 and December 2012, with a follow-up of
96%. There were 72 women and three men, with a mean age of 62 years
(35 to 79). The mean follow-up was nine years (2 to 14). The clinical condition
of each elbow before and after surgery was assessed using the Mayo
Elbow Performance Index (MEPI, 0 to 100 points). Radiographic loosening
was defined as a progressive radiolucent line of >1 mm that was
completely circumferential around the prosthesis.Aims
Patients and Methods