The objective of this study was to determine whether the bearing surface is a risk factor for revision after
Taper corrosion at modular junctions can cause a spectrum of adverse local tissue reactions (ALTR) in the periprosthetic soft tissues in patients who have undergone total hip arthroplasty (THA). Because these reactions are usually painful, taper corrosion has become part of the differential diagnosis of hip pain following THA. However these destructive lesions may not always cause pain, and can occasionally result in other atypical presentations. The purpose of this study is to describe a cohort of patients presenting with late and recurrent instability following THA due to underlying ALTR and taper corrosion. This is a multicenter retrospective case series of fourteen patients presenting with late instability secondary to ALTR and corrosion at the modular head-neck taper. The cohort included nine women and five men with a mean age of 66.8 years (range, 49 to 74). All patients had a metal (CoCr)-on-polyethylene bearing surface, but had a range of CoCr and Ti-alloy stem designs from three different manufacturers. Seven patients had 28 mm heads, while the rest had 32–40 mm heads. Patients experienced a mean of 3.4 dislocations (range, 2 to 6) at an average of 5.2 years (range, 0.4 to 17.0) following their index surgery. Although most reported some degree of discomfort around the hip, instability was the primary presenting symptom in all fourteen patients, and four were otherwise completely asymptomatic. Serum metal levels demonstrated a greater elevation of cobalt (mean 3.13 ng/mL) than chromium (mean 2.33 ng/mL). Preoperative infection workup including serum inflammatory markers and a hip aspiration documented the absence of sepsis.Introduction
Methods
The number one reason to consider large heads in total hip arthroplasty (THA) is for increased stability. Large diameter femoral heads substantially increase stability by virtue of increased range of motion and increased jump distance, which is the amount of displacement required to sublux the head out of the socket. Prevention is the best means for reducing dislocation, with requisites for stability being appropriate component position, restoration of leg length, and restoration of offset. In a review from our center studying the frequency of dislocation with small diameter femoral heads (≤32 mm) in 1262 patients (1518 hips) who underwent primary THA performed via a direct lateral approach, we observed a dislocation rate of 0.8% (12 of 1518). In a subsequent study of 1748 patients (2020 hips) who underwent primary THA at our center with large diameter heads (mean 43 mm, range 36–60 mm), we observed a substantially lower 0.04% frequency of dislocation (one of 2010) at a mean followup of 2.6 years. Our findings have been echoed in studies from several other centers. Howie et al. reported a prospective controlled trial of 644 low risk patients undergoing primary or revision THA randomised to receive either a 36 mm or 28 mm metal head articulated on highly crosslinked polyethylene. They observed significantly lower frequency of frequency of dislocation with 36 mm heads both overall (1.3%, 4 of 299 versus 5.4%, 17 of 216 with 28 mm heads, p=0.012) and in primary use (0.8%, 2 of 258 versus 4.4%, 12 of 275 with 28 mm heads, p=0.024), and a similar trend in their smaller groups of revision patients (5%, 2 of 41, versus 12%, 5 of 41 with 28 mm heads, p=0.273). Lachiewicz and Soileau reported on early and
Introduction. Dislocation is one of the leading causes of revision after primary total hip arthroplasty (THA). Polyethylene wear is one of the risk factors for
The number one reason to consider large heads in total hip arthroplasty (THA) is for increased stability. Large diameter femoral heads substantially increase stability by virtue of increased range of motion and increased jump distance, which is the amount of displacement required to sublux the head out of the socket. Prevention is the best means for reducing dislocation, with requisites for stability being appropriate component position, restoration of leg length, and restoration of offset. In a review from our center studying the frequency of dislocation with small diameter femoral heads (≤32 mm) in 1262 patients (1518 hips) who underwent primary THA performed via a direct lateral approach, we observed a dislocation rate of 0.8% (12 of 1518). In a subsequent study of 1748 patients (2020 hips) who underwent primary THA at our center with large diameter heads (mean 43 mm, range 36–60 mm), we observed a substantially lower 0.04% frequency of dislocation (one of 2010) at a mean followup of 2.6 years. Our findings have been echoed in studies from several other centers. Howie et al. reported a prospective controlled trial of 644 low risk patients undergoing primary or revision THA randomised to receive either a 36 mm or 28 mm metal head articulated on highly crosslinked polyethylene. They observed significantly lower frequency of frequency of dislocation with 36 mm heads both overall (1.3%, 4 of 299 versus 5.4%, 17 of 216 with 28 mm heads, p=0.012) and in primary use (0.8%, 2 of 258 versus 4.4%, 12 of 275 with 28 mm heads, p=0.024), and a similar trend in their smaller groups of revision patients (5%, 2 of 41 versus 12%, 5 of 41 with 28 mm heads, p=0.273). Lachiewicz and Soileau reported on early and
Purpose. The purpose of this study was to evaluate the complications related to the prosthesis design in patients managed with cemented total knee arthroplasty (TKA) with the anterior-posterior glide (APG) mobile bearing prosthesis. Materials and Methods. One hundred eighty three total knee arthroplasties were performed using APG Low Contact Stress mobile bearing prosthesis (Depuy, Warsaw, IN) on 146 patients with an average of 8.4 years follow-up (range, 7 to 10 years). Patients were evaluated clinically and radiologically according to the American Knee Society clinical scoring system. The anteroposterior translation, anterior soft tissue impingements, and complications were assessed at the follow-up periods. Results. No knee had loosening and measurable polyethylene wear on radiographs. There were
Introduction: The advantages of metal on metal bearings (MoM) include improved wear characteristics and lower dislocation rate. Metal sensitivity and Aseptic Lymphocyte Dominated Vasculitis Associated Lesion (ALVAL) reaction are becoming increasingly recognised. The BOA has recently issued a statement regarding MoM bearings. They suggested that any revisions for symptoms of pain and soft tissue reaction should be reported to the MHRA and histological specimens forwarded to the Stanmore Retrieval Centre. Methods and results: We report four patients (all females), who presented with
We assessed the clinical and radiological outcome of a single uncemented total hip replacement (THR) after twenty years, analysing polyethylene wear and osteolysis. 82 hips implanted between 1992 and 1995 were prospectively evaluated. Mean follow-up was 20.6 years (18–23). A hemispherical porous-coated cup matched to a proximally hydroxyapatite-coated anatomic stem. A 28mm PE liner, sterilised by gamma irradiation in air, was used in all hips. Radiological position, eventual loosening and osteolysis were recorded over time. Penetration of the head into the liner was measured by the Roentgen Monographic Analysis (ROMAN) Tool at 6 weeks, 6 months, one year and yearly thereafter. Six cups were revised due to wear and four cups because of
Two cases of assymptomatic hip dislocation discovered incidentally are presented. Case 1- A 63-year old lady had an uncemented primary total hip replacement of the left hip for painful osteoarthritis in July 1993. She made an uneventful recovery post-operatively. This lady had no neurological abnormality and was mobilising independently. In April 2001,8 years later she was admitted as an emergency for suspected diverticulitis of the colon. Plain radiographs performed showed dislocated hip prosthesis. Case 2- This 75-year old lady, an active farmer, had right hip arthroplasty in July 1990 for painful osteoarthritis and made an uneventful recovery subsequently. She also did not have any neurological abnormality and was mobilising independently too. Dislocated prosthesis was discovered radiologically in December 2001 during a pre-operative work-up for the left hip (the other hip) arthroplasty. Discussion:
Introduction. Durable bone fixation of uncemented porous-coated acetabular cups can be observed at a long-term, however, polyethylene (PE) wear and osteolysis may affect survivorship. Accurate wear measurements correlated with clinical data may offer unique research information of clinical interest about this highly debated issue. Objetive. We assessed the clinical and radiological outcome of a single uncemented total hip replacement (THR) after twenty years analysing polyethylene wear and the appearance of osteolysis. Materials and Methods. 82 hips implanted between 1992 and 1995 were prospectively evaluated with a mean follow-up of 20.6 years (range, 18 to 23). A hemispherical porous-coated acetabular cup matched to a proximally hydroxyapatite-coated anatomic stem and a 28 mm standard PE liner, sterilised by gamma irradiation in air, was used in all hips. Radiological position and the possible appearance of loosening and osteolysis were recorded over time. Penetration of the prosthetic head into the liner was measured by the Roentgen Monographic Analysis (ROMAN) Tool at 6 weeks, 6 months, one year and yearly thereafter. Results. Six cups were revised due to wear and four due to
Introduction. Durable bone fixation of uncemented porous-coated acetabular cups can be observed at a long-term, however, polyethylene (PE) wear and osteolysis may affect survivorship. Accurate wear measurements correlated with clinical data may offer unique research information of clinical interest about this highly debated issue. Objetive. We assessed the clinical and radiological outcome of a single uncemented total hip replacement (THR) system after twenty years analysing polyethylene wear and the appearance of osteolysis. Materials and Methods. 82 hips implanted between 1992 and 1995 were prospectively evaluated. The mean follow-up was 20.6 years (range, 18 to 23). A hemispherical porous-coated acetabular cup matched to a proximally hydroxyapatite-coated anatomic stem and a 28 mm standard PE liner, sterilised by gamma irradiation in air, was used in all hips. Radiological position and the possible appearance of loosening and osteolysis were recorded over time. Penetration of the prosthetic head into the liner was measured by the Roentgen Monographic Analysis (ROMAN) Tool at 6 weeks, 6 months, one year and yearly thereafter. Results. Six cups were revised due to wear and four due to
Spinopelvic characteristics influence the hip’s biomechanical behaviour. However, to date there is little knowledge defining what ‘normal’ spinopelvic characteristics are. This study aims to determine how static spinopelvic characteristics change with age and ethnicity among asymptomatic, healthy individuals. This systematic review followed the Preferred Reporting Items for Systematic Review and Meta-Analyses guidelines to identify English studies, including ≥ 18-year-old participants, without evidence of hip or spine pathology or a history of previous surgery or interventional treatment, documenting lumbar lordosis (LL), sacral slope (SS), pelvic tilt (PT), and pelvic incidence (PI). From a total of 2,543 articles retrieved after the initial database search, 61 articles were eventually selected for data extraction.Aims
Methods
The main causes of total hip arthroplasty (THA) revisions are loosening and instability. Use of a dual mobility cup cemented in a acetabular reconstruction cage device limits the risk of instability and does not hinder the acetabular fixation during THA revisions. The objective of this study was to analyse a retrospective series of 123 THA revisions with antiprotusio cage and dual mobility socket. Patients and methods: At a mean follow-up of 10 years, we analysed a continuous series of 123 revisions using a reconstruction device (87 Kerboull cross-plates, 12 Burch-Schneider antiprotrusio cages, 24 custom-fit Novae ARM cages associated in all cases with a Novae Stick dual mobility cup cemented into the cage). There were 80 women and 43 males. The mean age at the surgery was 69.2 years old. PMA score increased from 9.6 +/− 3.06 preoperatively to 14.2 +/− 2. at the follow-up. 9 early dislocations occurred and one
Introduction. Total hip arthroplasty (THA) instability is well documented to be more common in specific demographic groups. We report a retrospective analysis of the use of a dual mobility implant for primary hip replacements in selected patients at risk for dislocation. The aim of this study was to assess the long-term clinical and radiologic features associated with the dual mobility cup in case of primary THA. Materials and Methods. At our institution 119 primary THA were performed in 114 patients (74 females and 40 males) at high risk of instability between January 2000 and December 2002. 84% of the patients had at least two risk factors for dislocation. The mean age was 71 years old (range, 21.4 to 93.2 years) at the time of the arthroplasty. A dual mobility cup was used in all cases. Clinical result was assessed using Harris Hip Score, and complications were determined by detailed review of the patient's records. Radiographs of the involved joint were reviewed to assess the position of the prosthesis and to look for osteolysis and signs of loosening of the implant. Results. During the study period, 56 patients (47%) died of unrelated causes. 17 patients (15%) were lost to follow-up. For the remaining 41 patients (46 hips, 38%), the minimal follow-up was 10 years (119 to 154 months, mean 133 months). Harris hip score improved from 39.6 to 82.4 (p<0.05). Only one
Different bearing surfaces, including alumina-on-alumina have been used to avoid osteolysis. We ask if the use of modern ceramics matched with metal-backed sockets improves clinical results avoiding aseptic loosening, osteolysis and
Dual mobility components for total hip arthroplasty provide for an additional articular surface, with the goals of improving range of motion, jump distance, and overall stability of the prosthetic hip joint. A large polyethylene head articulates with a polished metal acetabular component, and an additional smaller metal head is snap-fit into the large polyethylene. New components have been released for use in North America over the past four years. In some European centers, these components are routinely used for primary total hip arthroplasty. Some surgeons in USA suggest routine use in primary hip arthroplasty. However, their greatest utility is to manage recurrent dislocation in the setting of revision total hip arthroplasty. Recent biomechanical data suggests that, in a 3D CT scan-cadaver hip model, there is no difference in range of motion between a 36mm head and an ADM dual mobility component sizes 50–56mm. There is little wear data on dual mobility components, except from one implant manufacturer. It is feared that there is a “3rd articulation” in dual mobility components—the routine impingement of the femoral neck against the polyethylene femoral head. Several retrospective series have shown satisfactory results for these dual mobility components at short- to medium-term follow-up times. There are important concerns with polyethylene wear,
Hip dislocation is one of the most common causes of patient and surgeon dissatisfaction following hip replacement. To correctly treat dislocation, the causes must first be understood. Patient factors included age greater than 70, medical co-morbidities, female gender, musculo-ligamentous laxity, revision surgery, issues with the abductors and trochanter and education. Issues related to the surgeon and technique are surgical volume and experience, the surgical approach and repair, adequate restoration of femoral offset and leg length, correct component position, and avoidance of soft tissue or bony impingement. There are also implant-related factors. Chief among these is the design of the head and neck region. Is the femoral head diameter sufficient, and in concert with the prosthetic neck is there an adequate head-neck ratio? Skirts on longer neck lengths greatly reduce the head-neck ratio and should be avoided if possible. There must be available offset choices in order to restore soft tissue tension. Lipped liners aid in gaining stability, yet if improperly placed may result in impingement and
Background:. Historically, performing a successful hip joint replacement in patients aged fewer than 30 years has been an orthopedic challenge. The newer generation of prostheses and surgical techniques has the potential to increase the longevity of implants. The purpose of this study was to evaluate the outcomes of cementless hip arthroplasty in patients aged fewer than 30 years. Materials and Methods:. In this cross-sectional study, 41 patients (46 hips) were studied with a mean age of 24, 4 (from 17 to 30 years) of whom underwent cementless metal – polyethylene hip arthroplasty from 2004 to 2007. The Harris hip score (HHS) was used to assess the functional consequences. Patients were followed up in terms of early complications (thrombophlebitis of the lower limbs, dislocation, hematoma and infection) and late complications (aseptic loosening, dislocation, and reoperation) at weeks 3 and 6, at 3 and 6 months, one year after surgery and annually thereafter. Results:. Patients were followed for an average of 5 years and 2 months (from 51 to 82 months). One early complication (symptomatic thrombophlebitis) and one
Introduction. Alumina-on-alumina in total hip replacement has been used for avoiding osteolysis and loosening. Published series report no ceramic wear and low rates for fractures and noises, but report poor results because of acetabular fixation failure. From 1999 to 2005, we used the “first generation” of a cementless cup, tri-radius relatively-smoothed HA coated (group 1), and from 2006 we have used a “second-generation” of this same cementless cup design with a macrotextured surface (group 2). We compare the perioperative conditions of two groups of patients using these two different cups and the clinical and radiological results. Material and Methods. We analysed 679 (612 patients) consecutive and non-selected primary cementless alumina-on-alumina prostheses. There were 342 hips in group 1 and 337 in group 2. The stem used for all patients in this series was the same and fitted with an Al2O3 liner and femoral head. The use of screws were according to the intraoperative stability of the cup (pull-out test). Patients’ mean age was 48.7+13.6 years and the average follow-up until revision or the last evaluation was 11.7 years for group 1 and 5.4 years for group 2. Results. Group 1, osteopenic and dysplastic acetabulae and women had a higher risk of screw use (p=0.004, p<0.001, p<0.001, p=0.011, respectively). Although the pre-operative clinical score was worse in group 2, the post-operative results were better (p<0.001).). No squeaking was found in any case. No alumina fractures occurred in this series. There was malseating of the liner in three hips, spontaneously resolved at six monthpostsurgery in all cases. No stem loosening, osteolysis or stress shielding were found in any case by the end of follow-up. Changes in linear femoral head penetration were not seen in any hip. There were 17 revised cups due to aseptic loosening, 15 were group 1 and two group 2. The probability of not having cup loosening was 93.3% (95% CI: 89.7 to 96.9) in group 1 and 97.5% (95% CI: 93.5 to 100) in group 2. Cup loosening was more frequent for severe congenital dysplasia of the hip (p<0.001) and in acetabular Dorr’ type C than in other types (p=0.0004). Of the hips revised for aseptic loosening, 6 were inside Lewinnek's safe zone versus 11 cups which was outside this zone (p<0.0001). Multivariate analysis showed that acetabular type C and cups outside Lewinnek´s safe zone had a higher risk for aseptic loosening (p<0.001, HR: 8.088, 95% CI 3.121–20.961; and p=0.003, HR: 5.128, 95% CI 1.773–14.829, respectively). Conclusions. Although the follow-up of this series is too short in the new Cerafit cup to allow definite conclusions, our data suggest that Cerafit alumina-on-alumina prostheses show excellent results after fifteen years. The macrotextured surface of the cup improved fixation compared to the early group Cup loosening was more frequent in severe congenital dysplasia, acetabular Dorr type C and in cups implanted outside of the Lewinnek's safe zone. Continued follow-up is required to determine if reduction in wear between the alumina-on alumina bearings results in less osteolysis, loosening, and