Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 4 - 4
1 Apr 2018
Pitto R Sedel L
Full Access

The objective of this study was to determine whether the bearing surface is a risk factor for revision after late dislocation in total hip arthroplasty (THA). Data from primary THAs were extracted from the New Zealand Joint Registry over a 13-year period. The mean age of patients was 68.9 years; 53.2% were female. The surgical approach used was posterior in 66% of THAs, lateral in 29% and anterior in 5%. There were 53,331 (65.1%) metal-on-polyethylene THAs, 14,093 (17.2%) ceramic-on-polyethylene, 8,177 (10.0%) ceramic-on-ceramic, 461 (0.5%) ceramic-on-metal, 5910, and (7.2%) metal-on-metal. The primary endpoint was late revision for dislocation, with ‘late’ defined as greater than one year post-operatively. 73,386 hips were available for analysis. The overall revision rate was 4.3% (3,130 THAs), 1.1% (836) were revised for dislocation. Only 0.65% (470) hips were revised for dislocation after the first post-operative year. The unadjusted hazard ratios (HR) showed significantly higher rates of revision for dislocation in ceramic-on-polyethylene (HR 2.48; p=0.001) and metal-on-polyethylene (HR 2.00; 95% p =0.007) compared to ceramic-on-ceramic. However, when adjusted for head size, age and surgical approach, only ceramic-on-polyethylene (HR 2.10; p=0.021) maintained a significantly higher rate of revision, whereas metal-on-polyethylene approached significance (HR 1.76; 95% p = 0.075). In New Zealand, dislocation is the most common reason for revision, ahead of aseptic loosening of the acetabular component. The relationships between bearing materials and risk of revision for late dislocation is controversial. However, in this study ceramic-on-ceramic shows lower risk rates for revision than other bearing surface combinations. Low wear and less debris, limited peri-articular inflammatory reaction and an healthy fibrotic pseudo-capsule are potential factors determining long-term stability of the hip joint


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 547 - 547
1 Aug 2008
Meek RMD Allan DB McPhillips G Kerr L Howie CR
Full Access

Introduction: Instability after total hip arthroplasty is an important complication. It commonly occurs in the immediate postoperative period, but the risk is reported to continue over time. There are numerous surgical treatment options, but they have relatively unpredictable outcomes. Numerous factors have been associated with dislocation, but research has mainly focused on surgical factors. Epidemiological factors remain the subject of much debate. We aimed to establish the incidence of dislocation over time.

Methods: The Scottish National arthroplasty non-voluntary registry is based on SMR01 records (Scottish Morbidity Record) data. We analyzed the Scottish National Arthroplasty Project to find patients’ dislocation rates up to 12 years post surgery.

Results: There were 62,175 total hip arthroplasties performed from April 1989 to March 2004 with an annual incidence of dislocation of 0.9%. The majority of dislocations occur by 12 months (66%) but patients remain at relatively high risk even after the first 3 months by when only 23% of the total have occurred. We found no increase in the rate of dislocation after 2 years.

Discussion: Patients should be warned that the risk of dislocation remains for the first year. However, it appears there is no late increase in dislocation rate associated with wear and declining mental or muscle function.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 274 - 274
1 Dec 2013
Cooper J Urban R Deirmengian C Paprosky W Jacobs JJ
Full Access

Introduction

Taper corrosion at modular junctions can cause a spectrum of adverse local tissue reactions (ALTR) in the periprosthetic soft tissues in patients who have undergone total hip arthroplasty (THA). Because these reactions are usually painful, taper corrosion has become part of the differential diagnosis of hip pain following THA. However these destructive lesions may not always cause pain, and can occasionally result in other atypical presentations. The purpose of this study is to describe a cohort of patients presenting with late and recurrent instability following THA due to underlying ALTR and taper corrosion.

Methods

This is a multicenter retrospective case series of fourteen patients presenting with late instability secondary to ALTR and corrosion at the modular head-neck taper. The cohort included nine women and five men with a mean age of 66.8 years (range, 49 to 74). All patients had a metal (CoCr)-on-polyethylene bearing surface, but had a range of CoCr and Ti-alloy stem designs from three different manufacturers. Seven patients had 28 mm heads, while the rest had 32–40 mm heads. Patients experienced a mean of 3.4 dislocations (range, 2 to 6) at an average of 5.2 years (range, 0.4 to 17.0) following their index surgery. Although most reported some degree of discomfort around the hip, instability was the primary presenting symptom in all fourteen patients, and four were otherwise completely asymptomatic. Serum metal levels demonstrated a greater elevation of cobalt (mean 3.13 ng/mL) than chromium (mean 2.33 ng/mL). Preoperative infection workup including serum inflammatory markers and a hip aspiration documented the absence of sepsis.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 43 - 43
1 Apr 2017
Lombardi A
Full Access

The number one reason to consider large heads in total hip arthroplasty (THA) is for increased stability. Large diameter femoral heads substantially increase stability by virtue of increased range of motion and increased jump distance, which is the amount of displacement required to sublux the head out of the socket. Prevention is the best means for reducing dislocation, with requisites for stability being appropriate component position, restoration of leg length, and restoration of offset. In a review from our center studying the frequency of dislocation with small diameter femoral heads (≤32 mm) in 1262 patients (1518 hips) who underwent primary THA performed via a direct lateral approach, we observed a dislocation rate of 0.8% (12 of 1518). In a subsequent study of 1748 patients (2020 hips) who underwent primary THA at our center with large diameter heads (mean 43 mm, range 36–60 mm), we observed a substantially lower 0.04% frequency of dislocation (one of 2010) at a mean followup of 2.6 years. Our findings have been echoed in studies from several other centers. Howie et al. reported a prospective controlled trial of 644 low risk patients undergoing primary or revision THA randomised to receive either a 36 mm or 28 mm metal head articulated on highly crosslinked polyethylene. They observed significantly lower frequency of frequency of dislocation with 36 mm heads both overall (1.3%, 4 of 299 versus 5.4%, 17 of 216 with 28 mm heads, p=0.012) and in primary use (0.8%, 2 of 258 versus 4.4%, 12 of 275 with 28 mm heads, p=0.024), and a similar trend in their smaller groups of revision patients (5%, 2 of 41, versus 12%, 5 of 41 with 28 mm heads, p=0.273). Lachiewicz and Soileau reported on early and late dislocation with 36- and 40 mm heads in 112 patients (122 hips) at presumed high risk for dislocation who underwent primary THA. Risk factors were age >75 for 80 hips, proximal femur fracture for 18, history of contralateral dislocation for 2, history of alcohol abuse in 2, large acetabulum (>60 mm) in 6, and other reasons in 14. Early dislocation (<1 year) occurred in 4% (5 of 122), all with 36 mm heads. Late dislocation (>5 years) did not occur in any of the 74 patients with followup beyond 5 years. Stroh et al. compared 225 patients (248 hips) treated with THA using small diameter heads (<36 mm) to 501 patients (559 hips) treated with THA using large diameter heads (≥36 mm). There were no dislocations with large diameter heads compared with 1.8% (10 of 559) with small diameter heads. Allen et al. studied whether or not large femoral heads improve functional outcome after primary THA via the posterior approach in 726 patients. There were 399 done with small heads (<36 mm), 254 with medium heads (36 mm), and 73 with large heads (>36 mm), analyzed pre-operatively, at 6 months, and at 12 months. The authors could not find a correlation between increasing head size and improved function at one year, but observed that dislocation was reduced with large diameter heads. Optimization of hip biomechanics via proper surgical technique, component position, and restoration of leg length and offset are mandatory in total hip arthroplasty. Large heads enhance stability by increasing range of motion prior to impingement and enhancing jump stability


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 26 - 26
1 May 2016
Shah S Walter W de Steiger R Munir S Tai S Walter W
Full Access

Introduction. Dislocation is one of the leading causes of revision after primary total hip arthroplasty (THA). Polyethylene wear is one of the risk factors for late dislocations (>2 years). It can induce an inflammatory response resulting in distension and thinning of the pseudocapsule, predisposing the hip to dislocation. Alternatively, eccentric seating of the femoral head in a worn out socket may result in an asymmetric excursion arc predisposing the hip to impingement, levering out and dislocation. Highly cross linked polyethylene has a significantly lower wear rate as compared to conventional polyethylene. Incidence of late dislocations has been shown to be significantly greater with conventional polyethylene bearings as compared to ceramic bearings. However, there is no literature comparing the risk of dislocation between ceramic- on- ceramic (CoC) bearings with metal/ceramic- on- cross linked polyethylene (M/CoP) bearings and this was the aim our study. Methods. Data regarding revision for dislocation after primary THA for osteoarthritis (OA) between September 1999 and December 2013 was obtained from the Australian Orthopaedic Association National Joint Replacement Registry (AOA NJRR). Revision risk for dislocation was compared between CoC, CoP, and MoP bearings. Only those THAs with 28 mm, 32 mm, or 36 mm heads were included in the study. Results. The numbers at risk (0 years) in the CoC, CoP, and MoP groups were 53,648; 23,746; and 90,040 THAs respectively. The overall revision (dislocation)/100 observed years was 0.13. Revision rate/100 observed years in the CoC, CoP, and MoP groups was 0.12, 0.12, and 0.16 respectively. The cumulative percentage revision for dislocation (CPRD) for the three bearing types is shown in figure 1. The CPRD at 12 years in the CoC, CoP, and MoP groups was 0.9, 1.0 and 1.2 respectively. The rise in CPRD between 2 and 12 years (late dislocations) was 0.4, 0.6, and 0.6 in the CoC, CoP, and MoP groups respectively (Figure 1). The age and gender adjusted hazards ratio (HR) for revision for dislocation in CoC vs. CoP groups was 1.05 (p=0.684, 1month+); in MoP vs. CoP group was 1.45 (p<0.001, entire period) and MoP vs. CoC group was 1.55 (p<0.001, 6 month+). Computation of age and gender adjusted HR comparing the three bearing groups after stratification according to head sizes (28 mm, 32 mm and 36 mm) showed no significant difference in HR after 3 months (p≥0.061). Conclusion. The revision (dislocation)/100 observed years was greater in the MoP group as compared to CoC and CoP groups (MoP > CoC = CoP). The age and gender adjusted HR (revision for dislocation) was significantly greater in the MoP group as compared to CoC and CoP groups after 6 months. However, when the data was stratified according to head sizes, the age and gender adjusted HR was similar between the three bearing groups after 3 months. In conclusion, there is no significant difference in the risk of revision for dislocation between CoC, CoP, and MoP bearings after adjusting for age, gender, and head size after 3 months


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 44 - 44
1 Dec 2016
Lombardi A
Full Access

The number one reason to consider large heads in total hip arthroplasty (THA) is for increased stability. Large diameter femoral heads substantially increase stability by virtue of increased range of motion and increased jump distance, which is the amount of displacement required to sublux the head out of the socket. Prevention is the best means for reducing dislocation, with requisites for stability being appropriate component position, restoration of leg length, and restoration of offset. In a review from our center studying the frequency of dislocation with small diameter femoral heads (≤32 mm) in 1262 patients (1518 hips) who underwent primary THA performed via a direct lateral approach, we observed a dislocation rate of 0.8% (12 of 1518). In a subsequent study of 1748 patients (2020 hips) who underwent primary THA at our center with large diameter heads (mean 43 mm, range 36–60 mm), we observed a substantially lower 0.04% frequency of dislocation (one of 2010) at a mean followup of 2.6 years. Our findings have been echoed in studies from several other centers. Howie et al. reported a prospective controlled trial of 644 low risk patients undergoing primary or revision THA randomised to receive either a 36 mm or 28 mm metal head articulated on highly crosslinked polyethylene. They observed significantly lower frequency of frequency of dislocation with 36 mm heads both overall (1.3%, 4 of 299 versus 5.4%, 17 of 216 with 28 mm heads, p=0.012) and in primary use (0.8%, 2 of 258 versus 4.4%, 12 of 275 with 28 mm heads, p=0.024), and a similar trend in their smaller groups of revision patients (5%, 2 of 41 versus 12%, 5 of 41 with 28 mm heads, p=0.273). Lachiewicz and Soileau reported on early and late dislocation with 36- and 40 mm heads in 112 patients (122 hips) at presumed high risk for dislocation who underwent primary THA. Risk factors were age >75 for 80 hips, proximal femur fracture for 18, history of contralateral dislocation for 2, history of alcohol abuse in 2, large acetabulum (>60 mm) in 6, and other reasons in 14. Early dislocation (<1 year) occurred in 4% (5 of 122), all with 36 mm heads. Late dislocation (>5 years) did not occur in any of the 74 patients with follow up beyond 5 years. Stroh et al. compared 225 patients (248 hips) treated with THA using small diameter heads (<36 mm) to 501 patients (559 hips) treated with THA using large diameter heads (≥36 mm). There were no dislocations with large diameter heads compared with 1.8% (10 of 559) with small diameter heads. Allen et al. studied whether or not large femoral heads improve functional outcome after primary THA via the posterior approach in 726 patients. There were 399 done with small heads (<36 mm), 254 with medium heads (36 mm), and 73 with large heads (>36 mm), analyzed preoperatively, at 6 months, and at 12 months. The authors could not find a correlation between increasing head size and improved function at one year, but observed that dislocation was reduced with large diameter heads. Optimization of hip biomechanics via proper surgical technique, component position, and restoration of leg length and offset are mandatory in total hip arthroplasty. Large heads enhance stability by increasing range of motion prior to impingement and enhancing jump stability


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 128 - 128
1 Jun 2012
Hwang B Lee W Park K Yang I Han C
Full Access

Purpose. The purpose of this study was to evaluate the complications related to the prosthesis design in patients managed with cemented total knee arthroplasty (TKA) with the anterior-posterior glide (APG) mobile bearing prosthesis. Materials and Methods. One hundred eighty three total knee arthroplasties were performed using APG Low Contact Stress mobile bearing prosthesis (Depuy, Warsaw, IN) on 146 patients with an average of 8.4 years follow-up (range, 7 to 10 years). Patients were evaluated clinically and radiologically according to the American Knee Society clinical scoring system. The anteroposterior translation, anterior soft tissue impingements, and complications were assessed at the follow-up periods. Results. No knee had loosening and measurable polyethylene wear on radiographs. There were late dislocations of bearing in 2 knees (1.1%), anterior soft tissue impingements in 6 knees (3.3%) at an earlier follow-up, abnormal anteroposterior translation in 5 knees (2.7%), and a fracture of the femoral component induced by osteolysis in 1 knee. Two patients with late dislocation of bearing had preoperative varus deformity more than 15° angulations and 20° flexion contracture. Conclusion. An improvement in a restraint mechanism of the APG mobile bearing prosthesis is needed to minimize the development of complications with regard to a combination of this design and patient factors


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 392 - 392
1 Jul 2010
Theruvil Vasukutty N Higgs D Hancock N Dunlop D Latham J
Full Access

Introduction: The advantages of metal on metal bearings (MoM) include improved wear characteristics and lower dislocation rate. Metal sensitivity and Aseptic Lymphocyte Dominated Vasculitis Associated Lesion (ALVAL) reaction are becoming increasingly recognised. The BOA has recently issued a statement regarding MoM bearings. They suggested that any revisions for symptoms of pain and soft tissue reaction should be reported to the MHRA and histological specimens forwarded to the Stanmore Retrieval Centre. Methods and results: We report four patients (all females), who presented with late dislocation of a large diameter MoM bearing (three following total hip replacements and one following resurfacing). They all made good initial recovery with complete relief of pain. They developed pain around groin between one and two years following the surgery. Inflammatory markers were normal. MRI/Ultrasound scanning showed the presence of cystic lesions around the hip. They all presented with relatively late dislocation (26 months to six years). At exploration there was a large joint effusion with necrosis and detachment of the abductors. A characteristic finding was an avascular bare trochanter stripped free of any soft tissues. Histology showed a predominantly histiocytic response in keeping with the findings of Willert and Pandit. Discussion: In the absence of any obvious causes for dislocation, one should have a high index of suspicion for the possibility of metal hypersensitivity causing joint effusion, muscle necrosis and thereby leading to instability due to the progressive periosteal and soft tissue erosion. These patients should be considered for early revision of the bearing surface to prevent further damage to the muscle and bone. If the abductors are completely detached a more constrained type of bearing should be used to improve the stability. To the best of our knowledge this is the first report of this unusual complication following MoM bearings


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 34 - 34
1 Aug 2018
García-Rey E García-Cimbrelo E Cordero-Ampuero J
Full Access

We assessed the clinical and radiological outcome of a single uncemented total hip replacement (THR) after twenty years, analysing polyethylene wear and osteolysis. 82 hips implanted between 1992 and 1995 were prospectively evaluated. Mean follow-up was 20.6 years (18–23). A hemispherical porous-coated cup matched to a proximally hydroxyapatite-coated anatomic stem. A 28mm PE liner, sterilised by gamma irradiation in air, was used in all hips. Radiological position, eventual loosening and osteolysis were recorded over time. Penetration of the head into the liner was measured by the Roentgen Monographic Analysis (ROMAN) Tool at 6 weeks, 6 months, one year and yearly thereafter. Six cups were revised due to wear and four cups because of late dislocation. All stems showed osseointegration and all cups appeared radiographically well-fixed. Six unrevised hips showed osteolysis on the acetabular side and two hips on the proximal femur. Creep at one year was 0.30±0.23 mm. Mean total femoral head penetration was 1.23mm at ten years, 1.52mm at 15 years and 1.92mm at 23 years. Overall mean wear was 0.12±0.1 mm/year and 0.09±0.06 mm/year after the creep period. Mean wear was 0.08±0.06 mm/year in hips without osteolysis and 0.14±0.03 mm/year in hips revised or hips with osteolysis (p<0.001). Although continued durable fixation can be observed with porous-coated cups and proximally hydroxyapatite-coated anatomic stems, true wear continues to increase at a constant level over time. PE wear remains as the main reason for osteolysis and revision surgery in uncemented THR after twenty years


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 50 - 50
1 Mar 2005
Lakdawala A El-Safty M Spencer J
Full Access

Two cases of assymptomatic hip dislocation discovered incidentally are presented. Case 1- A 63-year old lady had an uncemented primary total hip replacement of the left hip for painful osteoarthritis in July 1993. She made an uneventful recovery post-operatively. This lady had no neurological abnormality and was mobilising independently. In April 2001,8 years later she was admitted as an emergency for suspected diverticulitis of the colon. Plain radiographs performed showed dislocated hip prosthesis. Case 2- This 75-year old lady, an active farmer, had right hip arthroplasty in July 1990 for painful osteoarthritis and made an uneventful recovery subsequently. She also did not have any neurological abnormality and was mobilising independently too. Dislocated prosthesis was discovered radiologically in December 2001 during a pre-operative work-up for the left hip (the other hip) arthroplasty. Discussion: Late dislocation is more common than was thought previously. Several separate processes, some distinct from those associated with early dislocation, can lead to late dislocation. It can occur in association with a long-standing problem with the prosthesis that manifests late (such as malposition of the implant or recurrent subluxation), it can occur in association with a new problem (such as neurological abnormality, trauma or polyethylene wear), or it can occur in association with combination of these factors. Both these patients were mobilising independently and did not suffer from any neurological abnormality. Both these patients had asked to be discharged after an initial 2-year follow-up. They had not experienced any problem with the hip replacement. These dislocated prosthesis were discovered incidentally. Revision arthroplasty was carried out successfully in both these patients. These cases emphasise the need for long-term clinical and radiological follow-up in hip arthroplasty patients as hip dislocations can be assymptomatic and not detected by clinical examination. Radiological review alongside evaluation using scoring systems is recommended


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 60 - 60
1 Apr 2018
Garcia-Rey E Cimbrelo EG
Full Access

Introduction. Durable bone fixation of uncemented porous-coated acetabular cups can be observed at a long-term, however, polyethylene (PE) wear and osteolysis may affect survivorship. Accurate wear measurements correlated with clinical data may offer unique research information of clinical interest about this highly debated issue. Objetive. We assessed the clinical and radiological outcome of a single uncemented total hip replacement (THR) after twenty years analysing polyethylene wear and the appearance of osteolysis. Materials and Methods. 82 hips implanted between 1992 and 1995 were prospectively evaluated with a mean follow-up of 20.6 years (range, 18 to 23). A hemispherical porous-coated acetabular cup matched to a proximally hydroxyapatite-coated anatomic stem and a 28 mm standard PE liner, sterilised by gamma irradiation in air, was used in all hips. Radiological position and the possible appearance of loosening and osteolysis were recorded over time. Penetration of the prosthetic head into the liner was measured by the Roentgen Monographic Analysis (ROMAN) Tool at 6 weeks, 6 months, one year and yearly thereafter. Results. Six cups were revised due to wear and four due to late dislocation. All cups were radiographically well-fixed and all stems showed radiographic ingrowth. Six un-revised hips showed osteolysis on the acetabular side and two on the proximal femoral side. Creep at one year was 0.30 (±0.23) mm. Mean total femoral head penetration was 1.23 mm at 10 years, 1.52 mm at 15 years and 1.92 mm at 23 years. Overall mean wear was 0.12 (± 0.1) mm/year and 0.09 (±0.06) mm/year after the creep period. Mean wear was 0.08 (± 0.06) mm/year in hips without osteolysis and 0.14 (±0.03) mm/year in revised hips or with osteolysis (p<0.001). Conclusions. Although continued durable fixation can be observed with a porous-coated cups and a proximally hydroxyapatite-coated anatomic stem, true wear continues to increase at a constant level over time. PE wear remains as the main reason for revision surgery and osteolysis in uncemented THR after twenty years


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 9 - 9
1 Apr 2018
Garcia-Rey E Carbonell R Cordero J Gomez-Barrena E
Full Access

Introduction. Durable bone fixation of uncemented porous-coated acetabular cups can be observed at a long-term, however, polyethylene (PE) wear and osteolysis may affect survivorship. Accurate wear measurements correlated with clinical data may offer unique research information of clinical interest about this highly debated issue. Objetive. We assessed the clinical and radiological outcome of a single uncemented total hip replacement (THR) system after twenty years analysing polyethylene wear and the appearance of osteolysis. Materials and Methods. 82 hips implanted between 1992 and 1995 were prospectively evaluated. The mean follow-up was 20.6 years (range, 18 to 23). A hemispherical porous-coated acetabular cup matched to a proximally hydroxyapatite-coated anatomic stem and a 28 mm standard PE liner, sterilised by gamma irradiation in air, was used in all hips. Radiological position and the possible appearance of loosening and osteolysis were recorded over time. Penetration of the prosthetic head into the liner was measured by the Roentgen Monographic Analysis (ROMAN) Tool at 6 weeks, 6 months, one year and yearly thereafter. Results. Six cups were revised due to wear and four due to late dislocation. All cups were radiographically well-fixed and all stems showed radiographic ingrowth. Six un-revised hips showed osteolysis on the acetabular side and two on the proximal femoral side. Creep at one year was 0.30 (±0.23) mm. Mean total femoral head penetration was 1.23 mm at 10 years, 1.52 mm at 15 years and 1.92 mm at 23 years. Overall mean wear was 0.12 (± 0.1) mm/year and 0.09 (±0.06) mm/year after the creep period. Mean wear was 0.08 (± 0.06) mm/year in hips without osteolysis and 0.14 (±0.03) mm/year in revised hips or with osteolysis (p<0.001). Conclusions. Although continued durable fixation can be observed with a porous-coated cups and a proximally hydroxyapatite-coated anatomic stem, true wear continues to increase at a constant rate over time. PE wear remains as the main reason for revision surgery and osteolysis in uncemented THR and does not stop after twenty years


Bone & Joint Research
Vol. 12, Issue 4 | Pages 231 - 244
1 Apr 2023
Lukas KJ Verhaegen JCF Livock H Kowalski E Phan P Grammatopoulos G

Aims

Spinopelvic characteristics influence the hip’s biomechanical behaviour. However, to date there is little knowledge defining what ‘normal’ spinopelvic characteristics are. This study aims to determine how static spinopelvic characteristics change with age and ethnicity among asymptomatic, healthy individuals.

Methods

This systematic review followed the Preferred Reporting Items for Systematic Review and Meta-Analyses guidelines to identify English studies, including ≥ 18-year-old participants, without evidence of hip or spine pathology or a history of previous surgery or interventional treatment, documenting lumbar lordosis (LL), sacral slope (SS), pelvic tilt (PT), and pelvic incidence (PI). From a total of 2,543 articles retrieved after the initial database search, 61 articles were eventually selected for data extraction.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 86 - 86
1 Dec 2016
Philippot R Boyer B Neri T Farizon F
Full Access

The main causes of total hip arthroplasty (THA) revisions are loosening and instability. Use of a dual mobility cup cemented in a acetabular reconstruction cage device limits the risk of instability and does not hinder the acetabular fixation during THA revisions. The objective of this study was to analyse a retrospective series of 123 THA revisions with antiprotusio cage and dual mobility socket. Patients and methods: At a mean follow-up of 10 years, we analysed a continuous series of 123 revisions using a reconstruction device (87 Kerboull cross-plates, 12 Burch-Schneider antiprotrusio cages, 24 custom-fit Novae ARM cages associated in all cases with a Novae Stick dual mobility cup cemented into the cage). There were 80 women and 43 males. The mean age at the surgery was 69.2 years old. PMA score increased from 9.6 +/− 3.06 preoperatively to 14.2 +/− 2. at the follow-up. 9 early dislocations occurred and one late dislocation. At the last follow-up, the X-rays showed nine hardware failures, including one cross-plate fracture, one hook fracture, and one flange fracture. Analysis of the radiological position of the cup showed a mean lowering of 13 mm and a 7 mm lateralisation compared to the preoperative position. 2 revisions for aseptic loosening and 3 for septic loosening were performed. This study confirms the advantage of dual mobility cups during acetabular reconstruction cemented in antiprotrusio cages as a way to limit, without eliminating, the risk of dislocation. Therefore cemented fixation of dual mobility cups in cages appears to be a reliable short-term option


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 15 - 15
1 Jan 2016
Guyen O Wegrzyn J Pibarot V Bejui-Hugues J
Full Access

Introduction. Total hip arthroplasty (THA) instability is well documented to be more common in specific demographic groups. We report a retrospective analysis of the use of a dual mobility implant for primary hip replacements in selected patients at risk for dislocation. The aim of this study was to assess the long-term clinical and radiologic features associated with the dual mobility cup in case of primary THA. Materials and Methods. At our institution 119 primary THA were performed in 114 patients (74 females and 40 males) at high risk of instability between January 2000 and December 2002. 84% of the patients had at least two risk factors for dislocation. The mean age was 71 years old (range, 21.4 to 93.2 years) at the time of the arthroplasty. A dual mobility cup was used in all cases. Clinical result was assessed using Harris Hip Score, and complications were determined by detailed review of the patient's records. Radiographs of the involved joint were reviewed to assess the position of the prosthesis and to look for osteolysis and signs of loosening of the implant. Results. During the study period, 56 patients (47%) died of unrelated causes. 17 patients (15%) were lost to follow-up. For the remaining 41 patients (46 hips, 38%), the minimal follow-up was 10 years (119 to 154 months, mean 133 months). Harris hip score improved from 39.6 to 82.4 (p<0.05). Only one late dislocation was observed, 7 years after the surgery, in a 35-year old female with Mannosidosis. Two hips were revised at latest follow-up, for deep infections. No aseptic loosening of the cup or osteolysis was observed at latest follow-up. Conclusion. The dual mobility system was extremely successful in achieving stability in this continuous series of patients with increased risk for dislocation. In addition, no mechanical failure, and no osteolysis or aseptic loosening of the cup has been reported. The use of dual mobility cup to prevent instability in selected patients is a reliable option at long term follow-up


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 149 - 149
1 Jan 2016
Garcia-Cimbrelo E
Full Access

Different bearing surfaces, including alumina-on-alumina have been used to avoid osteolysis. We ask if the use of modern ceramics matched with metal-backed sockets improves clinical results avoiding aseptic loosening, osteolysis and late dislocations. We prospectively analysed 315 Cerafit cups in two different generations: First generation implanted between 1999 and 2005 (124 cups) and second generation (191 cups) all implanted with a 5-year minimum follow-up, and associated with a Multicone-HAP stem using alumina-on-alumina bearings. Patients' mean age was 48.7+13.6 years. There were three dislocations within the first postoperative month and one early recurrent dislocation requiring reoperation using a double mobility cup. There were four intraoperative fractures, two in rheumatoid juvenile arthritis cases solved with a cerclage, and one postoperative fracture solved using a femoral long-stem. No fractures were seen in the alumina components in this series. Also, there have been no infections. There were 4 patients reporting non-reproducible squeaking. Survivorship analysis for cup loosening for any cause was 93% for group 1 (11 cups) and 99.2% for group 2 (1 cup in a patient with severe developmental dysplasia). The cumulative probability of not having a revision of one or both components for any cause was 96.9% (CI 95%:9.47–99.1%), All unrevised cases showed good clinical and radiographic results at the end of follow-up. No stem loosening, osteolysis nor stress shielding were found in any case by the end of follow-up. Changes in linear femoral head penetration were not seen in any hip. These data suggest that Cerafit alumina-on-alumina prostheses show excellent results after fiften years. Cup loosening was more frequent in the cups of first generation, but not currently. Continued follow-up will be required to determine if reduction in wear between the alumina-on alumina bearings results in less osteolysis and loosening


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 4 - 4
1 Feb 2015
Lachiewicz P
Full Access

Dual mobility components for total hip arthroplasty provide for an additional articular surface, with the goals of improving range of motion, jump distance, and overall stability of the prosthetic hip joint. A large polyethylene head articulates with a polished metal acetabular component, and an additional smaller metal head is snap-fit into the large polyethylene. New components have been released for use in North America over the past four years. In some European centers, these components are routinely used for primary total hip arthroplasty. Some surgeons in USA suggest routine use in primary hip arthroplasty. However, their greatest utility is to manage recurrent dislocation in the setting of revision total hip arthroplasty. Recent biomechanical data suggests that, in a 3D CT scan-cadaver hip model, there is no difference in range of motion between a 36mm head and an ADM dual mobility component sizes 50–56mm. There is little wear data on dual mobility components, except from one implant manufacturer. It is feared that there is a “3rd articulation” in dual mobility components—the routine impingement of the femoral neck against the polyethylene femoral head. Several retrospective series have shown satisfactory results for these dual mobility components at short- to medium-term follow-up times. There are important concerns with polyethylene wear, late intra-prosthetic dislocation, and the lack of long-term follow-up data. Big femoral heads (36mm and 40mm) articulating with highly cross-linked, e-beam, remelted, polyethylene are a better choice in primary total hip arthroplasty, to decrease the frequency of dislocation in “high risk” patients. Although the risk of early dislocation was 4% in “high risk” patients, there was no recurrence, no revision, and no late first dislocation. Until further long-term results are available, caution is advised in the routine use of dual mobility components in primary total hip arthroplasty


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 39 - 39
1 May 2013
Brooks P
Full Access

Hip dislocation is one of the most common causes of patient and surgeon dissatisfaction following hip replacement. To correctly treat dislocation, the causes must first be understood. Patient factors included age greater than 70, medical co-morbidities, female gender, musculo-ligamentous laxity, revision surgery, issues with the abductors and trochanter and education. Issues related to the surgeon and technique are surgical volume and experience, the surgical approach and repair, adequate restoration of femoral offset and leg length, correct component position, and avoidance of soft tissue or bony impingement. There are also implant-related factors. Chief among these is the design of the head and neck region. Is the femoral head diameter sufficient, and in concert with the prosthetic neck is there an adequate head-neck ratio? Skirts on longer neck lengths greatly reduce the head-neck ratio and should be avoided if possible. There must be available offset choices in order to restore soft tissue tension. Lipped liners aid in gaining stability, yet if improperly placed may result in impingement and dislocation. Late dislocation may result from polyethylene wear, soft tissue destruction, trochanteric or abductor disruption and weakness, or infection. Understanding the causes of hip dislocation allow prevention in a majority of instances. Proper pre-operative planning includes the identification of high-offset patients in whom inadequate restoration of offset will reduce soft tissue tension and abductor efficiency. Component position must be accurate to achieve stability without impingement. Finally, patient education cannot be over-emphasised, as most dislocations occur early, and are preventable with proper instructions


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 410 - 410
1 Dec 2013
Mardani-Kivi M
Full Access

Background:. Historically, performing a successful hip joint replacement in patients aged fewer than 30 years has been an orthopedic challenge. The newer generation of prostheses and surgical techniques has the potential to increase the longevity of implants. The purpose of this study was to evaluate the outcomes of cementless hip arthroplasty in patients aged fewer than 30 years. Materials and Methods:. In this cross-sectional study, 41 patients (46 hips) were studied with a mean age of 24, 4 (from 17 to 30 years) of whom underwent cementless metal – polyethylene hip arthroplasty from 2004 to 2007. The Harris hip score (HHS) was used to assess the functional consequences. Patients were followed up in terms of early complications (thrombophlebitis of the lower limbs, dislocation, hematoma and infection) and late complications (aseptic loosening, dislocation, and reoperation) at weeks 3 and 6, at 3 and 6 months, one year after surgery and annually thereafter. Results:. Patients were followed for an average of 5 years and 2 months (from 51 to 82 months). One early complication (symptomatic thrombophlebitis) and one late dislocation (2.2%) were observed. There were no cases of aseptic loosening or osteolysis at the end of follow-up. The preoperative HHS was 59.6 (from 41 to 76), which rose to 82 and 83.5 after the one-year and final follow-up, respectively, which was a significantly increase. Conclusions:. Hip arthroplasty using a new generation of cementless proximal porous prosthesis with resistant polyethylene to cover the joint surfaces in patients aged fewer than 30 years is satisfactory and is accompanied by low complications. Keywords: Total hip replacement, hip arthroplasty, cementless Prosthesis, Hip osteoarthritis, osteonecrosis


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 146 - 146
1 May 2016
Garcia-Cimbrelo E Garcia-Rey E
Full Access

Introduction. Alumina-on-alumina in total hip replacement has been used for avoiding osteolysis and loosening. Published series report no ceramic wear and low rates for fractures and noises, but report poor results because of acetabular fixation failure. From 1999 to 2005, we used the “first generation” of a cementless cup, tri-radius relatively-smoothed HA coated (group 1), and from 2006 we have used a “second-generation” of this same cementless cup design with a macrotextured surface (group 2). We compare the perioperative conditions of two groups of patients using these two different cups and the clinical and radiological results. Material and Methods. We analysed 679 (612 patients) consecutive and non-selected primary cementless alumina-on-alumina prostheses. There were 342 hips in group 1 and 337 in group 2. The stem used for all patients in this series was the same and fitted with an Al2O3 liner and femoral head. The use of screws were according to the intraoperative stability of the cup (pull-out test). Patients’ mean age was 48.7+13.6 years and the average follow-up until revision or the last evaluation was 11.7 years for group 1 and 5.4 years for group 2. Results. Group 1, osteopenic and dysplastic acetabulae and women had a higher risk of screw use (p=0.004, p<0.001, p<0.001, p=0.011, respectively). Although the pre-operative clinical score was worse in group 2, the post-operative results were better (p<0.001).). No squeaking was found in any case. No alumina fractures occurred in this series. There was malseating of the liner in three hips, spontaneously resolved at six monthpostsurgery in all cases. No stem loosening, osteolysis or stress shielding were found in any case by the end of follow-up. Changes in linear femoral head penetration were not seen in any hip. There were 17 revised cups due to aseptic loosening, 15 were group 1 and two group 2. The probability of not having cup loosening was 93.3% (95% CI: 89.7 to 96.9) in group 1 and 97.5% (95% CI: 93.5 to 100) in group 2. Cup loosening was more frequent for severe congenital dysplasia of the hip (p<0.001) and in acetabular Dorr’ type C than in other types (p=0.0004). Of the hips revised for aseptic loosening, 6 were inside Lewinnek's safe zone versus 11 cups which was outside this zone (p<0.0001). Multivariate analysis showed that acetabular type C and cups outside Lewinnek´s safe zone had a higher risk for aseptic loosening (p<0.001, HR: 8.088, 95% CI 3.121–20.961; and p=0.003, HR: 5.128, 95% CI 1.773–14.829, respectively). Conclusions. Although the follow-up of this series is too short in the new Cerafit cup to allow definite conclusions, our data suggest that Cerafit alumina-on-alumina prostheses show excellent results after fifteen years. The macrotextured surface of the cup improved fixation compared to the early group Cup loosening was more frequent in severe congenital dysplasia, acetabular Dorr type C and in cups implanted outside of the Lewinnek's safe zone. Continued follow-up is required to determine if reduction in wear between the alumina-on alumina bearings results in less osteolysis, loosening, and late dislocations