Introduction. Perthes' disease is associated with coxa breva, plana and magna, and a high riding prominent greater trochanter causing abductor shortening and weakness, leg shortening and extra-articular impingement. A trochanteric advancement with an infero-lateralising oblique sliding osteotomy of the proximal femur would lengthen femoral neck, improve abductor length and strength, relieve impingement and improve leg length. We assessed the mid-term outcomes for this procedure. Method. We included patients who underwent the operation by the senior author (JNOH) with more than 2 years follow-up. The osteotomies were performed minimally invasively under image intensifier guidance and fixed with blade plate or locking plates. We assessed functional scores, radiological changes in neck length, Tonnis grading for arthritis and evidence of femoral head avascular necrosis, time interval for conversion to hip arthroplasty and associated complications. Results. Twenty four patients (25 hips) underwent the procedure at mean age of 18.7 years (range:9.3–38.8) with a mean follow-up of 5 years (range:2–13.8). At the last assessment, the mean Oxford Hip Score was 41.6 (range:58–27), Non-Arthritic Hip Score was 53.4 (range:25–77) and UCLA activity score was 4.2 (range:2–6). For changes in neck length, the mean “Head-centre-to-Greater-trochanteric-tip-distance” was 60 mm (range:43–78) compared to 39 mm (range:30–48) pre-operatively and the mean “Head-centre-to-Lesser-trochanteric-tip-distance” was 54 mm (range:47–64) compared to 37 mm (range:31–41) pre-operatively. The mean Tonnis grade was 1.5 (range:1–3) compared to 1.3 (range:1–2) pre-operatively. Two patients underwent arthroplasty conversion at 2 and 13.8 years later. One patient needed head-neck debridement for impingement and 2 patients underwent trochanteric refixation for non-union. There were no cases of avascular necrosis. Discussion. Symptomatic Perthes'
Introduction. Perthes disease is associated with coxa breva, plana and magna, and a high riding prominent greater trochanter causing abductor shortening and weakness, leg shortening and extra-articular impingement. A trochanteric advancement with an infero-lateralizing sliding osteotomy of the proximal femur would lengthen femoral neck, improve abductor length and strength, relieve impingement and improve leg length. We assessed the mid-term outcomes for this procedure. Method. We included patients who underwent the operation by the senior author (JNOH) with more than 2 years follow-up. The osteotomies were performed under image intensifier guidance and fixed with blade plate or locking plates. We assessed functional scores, radiological changes in neck length, Tonnis grading for arthritis and evidence of progression in femoral head avascular necrosis, time interval for conversion to hip arthroplasty and associated complications. Results. Twenty four patients (25 hips) underwent the procedure at mean age of 18.7 years (range:9.3–38.8) with a mean follow-up of 5 years (range:2–13.8). At the last assessment, the mean Oxford Hip Score was 41.6 (range:58–27), Non-Arthritic Hip Score was 53.4 (range:25–77) and UCLA activity score was 4.2 (range:2–6). For changes in neck length, the mean “Head-centre-to-Greater-trochanteric-tip-distance” was 60 mm (range:43–78) compared to 39 mm (range:30–48) pre-operatively and the mean “Head-center-to-Lesser-trochanteric-tip-distance” was 54 mm (range:47–64) compared to 37 mm (range:31–41) pre-operatively. The mean Tonnis grade was 1.5 (range:1–3) compared to 1.3 (range:1–2) pre-operatively. Two patients underwent arthroplasty conversion at 2 and 13.8 years later. One patient needed head-neck debridement for impingement and 2 patients underwent trochanteric refixation for non-union. There was no progression in avascular necrosis of femoral head. Discussion. Symptomatic Perthes
An experimental piglet model induces avascular necrosis (AVN)
and deformation of the femoral head but its secondary effects on
the developing acetabulum have not been studied. The aim of this
study was to assess the development of secondary acetabular deformation
following femoral head ischemia. Intracapsular circumferential ligation at the base of the femoral
neck and sectioning of the ligamentum teres were performed in three
week old piglets. MRI was then used for qualitative and quantitative
studies of the acetabula in operated and non-operated hips in eight
piglets from 48 hours to eight weeks post-surgery. Specimen photographs and
histological sections of the acetabula were done at the end of the
study. Objectives
Methods
Executing an extended retinacular flap containing the blood supply for the femoral head, reduction osteotomy (FHO) can be performed, increasing the potential of correction of complex hip morphologies. The aim of this study was to analyse the safety of the procedure and report the clinical and radiographic results in skeletally mature patients with a minimum follow up of two years. Twelve symptomatic patients (12 hips) with a mean age of 17 years underwent FHO using surgical hip dislocation and an extended soft tissue flap. Radiographs and magnetic resonance imaging producing radial cuts (MRI) were obtained before surgery and radiographs after surgery to evaluate articular congruency, cartilage damage and morphologic parameters. Clinical functional evaluation was done using the Non-Arthritic Hip Score (NAHS), the Hip Outcome Score (HOS), and the modified Harris Hip Score (mHHS). After surgery, at the latest follow-up no symptomatic avascular necrosis was observed and all osteotomies healed without complications. Femoral head size index improved from 120 ± 10% to 100 ± 10% (p<0,05). Femoral head sphericity index improved from 71 ± 10% before surgery to 91 ± 7% after surgery (p<0,05). Femoral head extrusion index improved from 37 ± 17% to 5 ± 6% (p< 0,05). Twenty five percent of patients had an intact Shenton line before surgery. After surgery this percentage was 75% (p<0,05). The NAHS score improved from a mean of 41 ± 18 to 69 ± 9 points after surgery (p< 0,05). The HOS score improve from 56 ± 24 to 83 ± 17 points after surgery (p< 0,05) and the mHHS score improved from 46 ± 15 before surgery to 76 ± 13 points after surgery (p< 0,05). In this series, femoral head osteotomy could be considered as safe procedure with considerable potential to correct
Femoroacetabular impingement (FAI) patients report exacerbation of hip pain in deep flexion. However, the exact impingement location in deep flexion is unknown. The aim was to investigate impingement-free maximal flexion, impingement location, and if cam deformity causes hip impingement in flexion in FAI patients. A retrospective study involving 24 patients (37 hips) with FAI and femoral retroversion (femoral version (FV) < 5° per Murphy method) was performed. All patients were symptomatic (mean age 28 years (SD 9)) and had anterior hip/groin pain and a positive anterior impingement test. Cam- and pincer-type subgroups were analyzed. Patients were compared to an asymptomatic control group (26 hips). All patients underwent pelvic CT scans to generate personalized CT-based 3D models and validated software for patient-specific impingement simulation (equidistant method).Aims
Methods
This study aimed to evaluate the relationship between hip shape and mid-term function in Perthes’ disease. It also explored whether the modified three-group Stulberg classification can offer similar prognostic information to the five-group system. A total of 136 individuals aged 12 years or older who had Perthes’ disease in childhood completed the Patient-Reported Outcomes Measurement Information System (PROMIS) Mobility score (function), Nonarthritic Hip Score (NAHS) (function), EuroQol five-dimension five-level questionnaire (EQ-5D-5L) score (quality of life), and the numeric rating scale for pain (NRS). The Stulberg class of the participants’ hip radiographs were evaluated by three fellowship-trained paediatric orthopaedic surgeons. Hip shape and Stulberg class were compared to PROM scores.Aims
Methods
Developmental dysplasia of the hip (DDH) can be managed effectively with non-surgical interventions when diagnosed early. However, the likelihood of surgical intervention increases with a late presentation. Therefore, an effective screening programme is essential to prevent late diagnosis and reduce surgical morbidity in the population. We conducted a systematic review and meta-analysis of the epidemiological literature from the last 25 years in the UK. Articles were selected from databases searches using MEDLINE, EMBASE, OVID, and Cochrane; 13 papers met the inclusion criteria.Aims
Methods
Background. We have performed total knee arthroplasties for valgus and varus in the knees of one person and investigate the clinical characteristics of these patients and the relationship between the kind of deformity and postoperative result. Methods. From March 2002 to February 2010, 25 patients who had simultaneous varus and valgus knee deformities underwent total knee arthroplasties and followed more than 12 months were included. The average age was 66.9 years and the average follow-up period was 61.1 months. Follow-up imaging assessments were taken and clinical outcome were evaluated using HSS score at last follow-up. Results. 11 cases had more pain in varus knee and 8 cases had more pain in valgus knee preoperatively. In 11 cases, degenerative scoliosis were associated with the knee deformity and among the cases, 10 cases had valgus deformities in concave side of scoliosis. In three cases,
To evaluate how abnormal proximal femoral anatomy affects different femoral version measurements in young patients with hip pain. First, femoral version was measured in 50 hips of symptomatic consecutively selected patients with hip pain (mean age 20 years (SD 6), 60% (n = 25) females) on preoperative CT scans using different measurement methods: Lee et al, Reikerås et al, Tomczak et al, and Murphy et al. Neck-shaft angle (NSA) and α angle were measured on coronal and radial CT images. Second, CT scans from three patients with femoral retroversion, normal femoral version, and anteversion were used to create 3D femur models, which were manipulated to generate models with different NSAs and different cam lesions, resulting in eight models per patient. Femoral version measurements were repeated on manipulated femora.Aims
Methods
Background. Pre-operative autologous blood donation is recommended as a means of reducing the need for allogeneic transfusion before simultaneous bilateral total hip arthroplasty (THA). However, there have been few reports on the optimal amount of autologous donation for this procedure. In this study we sought to determine the amount of autologous blood required for patient undergoing simultaneous bilateral THA using the direct anterior approach. Methods. We retrospectively enrolled 325 consecutive patients (650 hips) underwent simultaneous bilateral primary THA from January 2012 to June 2014. Thirty-three patients were men and 290 patients were women. The patients’ mean age at THA was 59.1 years. All THAs were performed using the direct anterior approach. Intraoperative blood salvage was applied for all patients and postoperative blood salvage was not applied for any patients. Results. The mean intraoperative blood loss and the mean operative time for the bilateral procedure were 413±165 g and 87.2±12.3 minutes, respectively. Two hundreds and forty-one of the 325 patients (74.2%) donated an average of 1.9 (range, 1–2) units of autologous blood before the operation. The mean hemoglobin levels on the preoperative day, postoperative day 1 and postoperative day 5 were 12.5g/dl, 10.5 g/dl and 9.5 g/dl, respectively. Only 1 patient (0.3%) required postoperative transfusions of allogeneic blood. All of the autologous units collected were transfused, and no units were wasted. Conclusion. Simultaneous bilateral THA can be performed without allogenic blood transfusion in 99.7% of patients. We could not find out significant effectiveness of an average of 1.9 units of autologous blood donation for this procedure in this study. We concluded that simultaneous bilateral THA can be performed without autologous blood donation in healthy patients without severe
Traditionally, total hip arthroplasty (THA) templating has been performed on anteroposterior (AP) pelvis radiographs. Recently, additional AP hip radiographs have been recommended for accurate measurement of the femoral offset (FO). To verify this claim, this study aimed to establish quantitative data of the measurement error of the FO in relation to leg position and X-ray source position using a newly developed geometric model and clinical data. We analyzed the FOs measured on AP hip and pelvis radiographs in a prospective consecutive series of 55 patients undergoing unilateral primary THA for hip osteoarthritis. To determine sample size, a power analysis was performed. Patients’ position and X-ray beam setting followed a standardized protocol to achieve reproducible projections. All images were calibrated with the KingMark calibration system. In addition, a geometric model was created to evaluate both the effects of leg position (rotation and abduction/adduction) and the effects of X-ray source position on FO measurement.Aims
Methods
Sitting is the main activity of daily living for the majority of patients with cerebral palsy. More than 60% of dependent sitters have hip disorders. Surgical management of hip and pelvic postural mal-alignment remains controversial. The aim of this study was to investigate effectiveness of open hip release in patients with spastic
The aim of this study is to define a core outcome set (COS) to allow consistency in outcome reporting amongst studies investigating the management of orthopaedic treatment in children with spinal dysraphism (SD). Relevant outcomes will be identified in a four-stage process from both the literature and key stakeholders (patients, their families, and clinical professionals). Previous outcomes used in clinical studies will be identified through a systematic review of the literature, and each outcome will be assigned to one of the five core areas, defined by the Outcome Measures in Rheumatoid Arthritis Clinical Trials (OMERACT). Additional possible outcomes will be identified through consultation with patients affected by SD and their families.Aims
Methods
Purpose. To assess the use of radiographic measurement compared to descriptive classification in the evaluation of Perthes'
disease. Method. Fifteen consultant Paediatric Orthopaedic surgeons, members of the BOSS Collaborative from different UK centres, were asked to rate a series of 100 healed AP radiographs of hips affected by Perthes'
Disease from the Liverpool Perthes'
Disease Register using the Stulberg'
s grading. Two independent observers categorised roundness error using Digitimizer™ software. Kappa scores were used to determine the inter-observer concordance amongst the 15 observers for Stulberg classification. Lin concordance was used to determine roundness error assessment. The relationship between the two outcomes was explored statistically and graphically; considering the mean Stulberg grade recorded by the 15 observers as a continuous outcome. Results. There was moderate to fair agreement regarding the Stulberg'
s grading among the Consultant surgeons with an overall Kappa error of 0.377 (95%
0.353 – 0.393). The Lin concordance between the two independent observers evaluating roundness error was 0.50 (95%
CI 0.36–0.64). There was a strong correlation between the Stulberg grading and roundness error measurement. Using a box and whisker chart the roundness error correlated well with modal Stulberg grade. Conclusion. Roundness error appears to be a useful radiographic measure of hip shape in Perthes'
disease by offering a continuous estimate of
Introduction and Aims: The authors present their results following treatment of 15 patients with complex
We present a study done to measure the change of angle of the acetabulum or cup, due to leg length discrepancy,
Cam-type femoral acetabular impingement (FAI), is a common structural
Background: Structural
Modulus femoral prosthesis is a modular cementless femoral system which consists of 5 degree tapered conical stem made of a titanium alloy with 8 fins of 1mm and modular neck. Modular neck enables to control any ideal stem anteversion as a surgeon prefers. This system is considered to be useful in severe