Advertisement for orthosearch.org.uk
Results 1 - 20 of 6988
Results per page:
Bone & Joint Open
Vol. 4, Issue 5 | Pages 385 - 392
24 May 2023
Turgeon TR Hedden DR Bohm ER Burnell CD

Aims. Instability is a common cause of failure after total hip arthroplasty. A novel reverse total hip has been developed, with a femoral cup and acetabular ball, creating enhanced mechanical stability. The purpose of this study was to assess the implant fixation using radiostereometric analysis (RSA), and the clinical safety and efficacy of this novel design. Methods. Patients with end-stage osteoarthritis were enrolled in a prospective cohort at a single centre. The cohort consisted of 11 females and 11 males with mean age of 70.6 years (SD 3.5) and BMI of 31.0 kg/m. 2. (SD 5.7). Implant fixation was evaluated using RSA as well as Western Ontario and McMaster Universities Osteoarthritis Index, Harris Hip Score, Oxford Hip Score, Hip disability and Osteoarthritis Outcome Score, 38-item Short Form survey, and EuroQol five-dimension health questionnaire scores at two-year follow-up. At least one acetabular screw was used in all cases. RSA markers were inserted into the innominate bone and proximal femur with imaging at six weeks (baseline) and six, 12, and 24 months. Independent-samples t-tests were used to compare to published thresholds. Results. Mean acetabular subsidence from baseline to 24 months was 0.087 mm (SD 0.152), below the critical threshold of 0.2 mm (p = 0.005). Mean femoral subsidence from baseline to 24 months was -0.002 mm (SD 0.194), below the published reference of 0.5 mm (p < 0.001). There was significant improvement in patient-reported outcome measures at 24 months with good to excellent results. Conclusion. RSA analysis demonstrates excellent fixation with a predicted low risk of revision at ten years of this novel reverse total hip system. Clinical outcomes were consistent with safe and effective hip replacement prostheses. Cite this article: Bone Jt Open 2023;4(5):385–392


Aims. Olecranon fractures are usually caused by falling directly on to the olecranon or following a fall on to an outstretched arm. Displaced fractures of the olecranon with a stable ulnohumeral joint are commonly managed by open reduction and internal fixation. The current predominant method of management of simple displaced fractures with ulnohumeral stability (Mayo grade IIA) in the UK and internationally is a low-cost technique using tension band wiring. Suture or suture anchor techniques have been described with the aim of reducing the hardware related complications and reoperation. An all-suture technique has been developed to fix the fracture using strong synthetic sutures alone. The aim of this trial is to investigate the clinical and cost-effectiveness of tension suture repair versus traditional tension band wiring for the surgical fixation of Mayo grade IIA fractures of the olecranon. Methods. SOFFT is a multicentre, pragmatic, two-arm parallel-group, non-inferiority, randomized controlled trial. Participants will be assigned 1:1 to receive either tension suture fixation or tension band wiring. 280 adult participants will be recruited. The primary outcome will be the Disabilities of the Arm, Shoulder and Hand (DASH) score at four months post-randomization. Secondary outcome measures include DASH (at 12, 18, and 24 months), pain, Net Promotor Score (patient satisfaction), EuroQol five-dimension five-level score (EQ-5D-5L), radiological union, complications, elbow range of motion, and re-operations related to the injury or to remove metalwork. An economic evaluation will assess the cost-effectiveness of treatments. Discussion. There is currently no high-quality evidence comparing the clinical and cost effectiveness of the tension suture repair to the traditional tension band wiring currently offered for the internal fixation of displaced fractures of the olecranon. The Simple Olecranon Fracture Fixation Trial (SOFFT) is a randomized controlled trial with sufficient power and design rigour to provide this evidence for the subtype of Mayo grade IIA fractures. Cite this article: Bone Jt Open 2023;4(1):27–37


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 55 - 55
11 Apr 2023
Raina D Markeviciute V Arvidsson L Törnquist E Stravinskas M Kok J Jacobson I Liu Y Tengattini A Sezgin E Vater C Zwingenberger S Isaksson H Tägil M Tarasevicius S Lidgren L
Full Access

Majority of osteoporosis related fractures are treated surgically using metallic fixation devices. Anchorage of fixation devices is sometimes challenging due to poor osteoporotic bone quality that can lead to failure of the fracture fixation. Using a rat osteoporosis model, we employed neutron tomography and histology to study the biological effects of implant augmentation using an isothermally setting calcium sulphate/hydroxyapatite (CaS/HA) biomaterial with synthetic HA particles as recruiting moiety for systemically administered bisphosphonates. Using an osteoporotic sawbones model, we then provide a standardized method for the delivery of the CaS/HA biomaterial at the bone-implant interface for improved mechanical anchorage of a lag-screw commonly used for hip fracture fixation. As a proof-of-concept, the method was then verified in donated femoral heads and in patients with osteoporosis undergoing hip fracture fixation. We show that placing HA particles around a stainless-steel screw in-vivo, systemically administered bisphosphonates could be targeted towards the implant, yielding significantly higher peri-implant bone formation compared to un-augmented controls. In the sawbones model, CaS/HA based lag-screw augmentation led to significant increase (up to 4 times) in peak extraction force with CaS/HA performing at par with PMMA. Micro-CT imaging of the CaS/HA augmented lag-screws in cadaver femoral heads verified that the entire length of the lag-screw threads and the surrounding bone was covered with the CaS/HA material. X-ray images from fracture fixation surgery indicated that the CaS/HA material could be applied at the lag-screw-bone interface without exerting any additional pressure or risk of venous vascular leakage.: We present a new method for augmentation of lag-screws in fragile bone. It is envisaged that this methodcould potentially reduce the risk of fracture fixation failure especially when HA seeking “bone active” drugs are used systemically


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 49 - 49
1 Jun 2023
Thompson E Shamoon S Qureshi A
Full Access

Introduction. Circular external fixators are fundamental to lower limb reconstruction, primarily in situations with a high risk of infection such as open fractures. During the Covid-19 pandemic, use of circular frames in our unit decreased, following departmental approval, due to resource management and in keeping with BOA guidelines as we opted to “consider alternative techniques for patients who require soft tissue reconstruction to avoid multiple operations”. These alternatives included the use of internal fixation (plate osteosynthesis and intramedullary nailing) as a measure to reduce the number of hospital attendances for patients and to conserve resources. This change in practice has continued in part following the pandemic with the increased use of internal fixation in cases previously deemed unsuitable for such techniques. We present our experience of this treatment strategy in the management of complex lower limb injuries, focusing on outcomes and consider the lessons learnt. Materials & Methods. Data of patients with complex lower limb injuries treated before, during and after the pandemic were collected from our in-house trauma database, theatre records and follow up clinics. The rationale for choosing other techniques over a circular frame, the type of alternative technique used, the cost of such alternatives, the need for soft tissue reconstruction, time to recovery, complications and amputation rates were compared among groups. Results. These data suggest comparable outcomes between circular frames and alternative techniques can be achieved. A notable reduction in the number of circular frames applied during the review period was observed. Furthermore, frame fixation was associated with more frequent outpatient review and the associated implications for resource management. Conclusions. Conclusion: The Covid-19 pandemic has posed great challenges to the Trauma and Orthopaedic community, forcing us to be flexible by adopting alternative treatment methods to traditional circular external fixation. These alternatives have proven feasible and potentially more cost effective, prompting their adoption in the post pandemic era. However, this change of practice is not without potential consequences and continued investigation is warranted


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 14 - 14
10 May 2024
Mooya S Berney M Cleary M Rowan F
Full Access

Introduction. The condition of the soft tissues surrounding an ankle fracture influences timing and treatment of injuries. Conventional treatment used an open approach to facilitate anatomical reduction and rigid internal fixation. Intramedullary devices for fibular fractures provide a safe alternative in patients in which the condition of the soft tissue envelope or the patient's co-morbidities may benefit from a less invasive approach. We compared outcomes for patients treated with open reduction internal fixation (ORIF) with those undergoing treatment with fibular nails (FN). Methods. 13 consecutive patients treated with fibular nails (FN) were compared with 13 age-matched patients that underwent open reduction and internal fixation (ORIF). All patients were followed to union. Study outcomes were time from admission to surgery, length of stay, wound failure, implant failure, revision surgery, OMAS and SF-36. Results. There was no difference in age or sex distribution between groups. There was no difference in OMAS at 1 year (83 ± 9 in FN group; 80± 21 in ORIF group) and SF-36 (94 ± 11 and 90 ± 20). There were 2 implant failures in the ORIF group and none in the FN group. There was one wound failure in the ORIF group and none in the FN group. Patients treated with FN had a shorter time to surgery (1 day ± 24 hours vs 3 days ± 24 hours) and shorter length of stay (1 day ± 24 hours vs 4 days ± 96 hours). Conclusion. FN is a safe method to treat patients with displaced distal fibular fractures that may have a poor soft tissue envelope and risk factors for wound healing. FN reduces the time to surgery and overall length of stay compared with similar patients treated with conventional ORIF


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_14 | Pages 2 - 2
10 Oct 2023
Heinz N Bugler K Clement N Low X Duckworth A White T
Full Access

To compare the long-term outcomes of fibular nailing and plate fixation for unstable ankle fractures in a cohort of patients under the age of 65 years. Patients from a previously conducted randomized control trial comparing fibular nailing and plate fixation were contacted at a minimum of 10 years post intervention at a single study centre. Short term data were collected prospectively and long-term data were collected retrospectively using an electronic patient record software. Ninety-nine patients from one trauma centre were included (48 fibular nails and 51 plate fixations). Groups were matched for gender (p = 0.579), age (p = 0.811), body mass index (BMI)(p = 0.925), smoking status (p = 0.209), alcohol status (p = 0.679) and injury type (p = 0.674). Radiographically at an average of 2 years post-injury, there was no statistically significant difference between groups for development of osteoarthritis (p = 0.851). Both groups had 1 tibio-talar fusion (2% of both groups) secondary to osteoarthritis with no statistically significant difference in overall re-operation rate between groups identified (p = 0.518,). Forty-five percent (n=42) of patients had so far returned patient reported outcome measures at a minimum of 10 years (Fibular nail n=19, plate fixation n=23). No significant difference was found between groups at 10 years for the Olerud and Molander Ankle Score (p = 0.990), the Manchester-Oxford Foot Questionnaire (p = 0.288), Euroqol-5D Index (p = 0.828) and Euroqol-5D Visual Analogue Score (p = 0.769). The current study illustrates no difference between fibular nail fixation and plate fixation at a long-term follow up of 10 years in patients under 65 years old, although the study is currently under powered


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 2 - 2
17 Jun 2024
Fishley W Morrison R Baldock T Hilley A Baker P Townshend D
Full Access

Background. In fixation of the fibula in ankle fractures, AO advocate using a lag screw and one-third tubular neutralisation plate for simple patterns. Where a lag screw cannot be placed, bridging fixation is required. A local pilot service evaluation previously identified variance in use of locking plates in all patterns with significant cost implications. The FAIR study aimed to evaluate current practice and implant use across the United Kingdom (UK) and review outcomes and complication rates between different fibula fixation methods. Method. The study was supported by CORNET, the North East trainee research collaborative, and BOTA. Data was collected using REDCap from 22 centres in the UK retrospectively for a one-year period between 1. st. January 2019 and 31. st. December 2019 on injury mechanism, fracture characteristics, comorbidities, fixation and complications. Follow-up data was collected to at least two-years from the time surgery. Results. 1448 ankle fractures which involved fixation of the fibula were recorded; one-third tubular plate was used in 866 (59.8%) cases, a locking plate in 463 (32.0%) cases and other methods in 119 (8.2%) cases. There was significant difference between centres (p<0.001) in implant type used. Other factors associated with implant type were age, diabetes, osteoporosis, open fractures, fracture pattern and the presence of comminution. Incidence of lateral wound breakdown was higher in locking plates than one-third tubular plates (p<0.05). There was no significant difference in infection, non-union, fixation failure or removal of metalware. Conclusion. There is significant variation in practice in the UK in implant use for fixation of the fibula in ankle fractures. Potentially unnecessary use of locking plates, where a one-third tubular shows equivalent outcomes, incurs additional cost and may increase the risk of lateral wound breakdown. We would encourage surgeons with high locking plate usage to evaluate their own unit's practice against this data


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_14 | Pages 11 - 11
23 Jul 2024
Sarhan M Moreau J Francis S Page P
Full Access

Hip fractures frequently occur in elderly patients with osteoporosis and are rapidly increasing in prevalence owing to an increase in the elderly population and social activities. We experienced several recent presentations of TFNA nails failed through proximal locking aperture which requires significant revision surgery in often highly co-morbid patient population. The study was done by retrospective data collection from 2013 to 2023 of all the hip fractures which had been fixed with Cephalomedullary nails to review and compare Gamma (2013–2017) and TFNA (2017–2023) failure rates and the timing of the failures. Infected and Elective revision to Arthroplasty cases were excluded. The results are 1034 cases had been included, 784 fixed with TFNA and 250 cases fixed Gamma nails. Out of the 784 patients fixed with TFNA, 19 fixation failed (2.45%). Out of the 250 cases fixed with Gamma nails, 15 fixation failed (6%). Mean days for fixation failure were 323 and 244 days in TFNA and Gamma nails respectively. We conclude that TFNA showed remarkable less failure rates if compared to Gamma nails. At point of launch, testing was limited and no proof of superiority of TFNA over Gamma nail. Several failures identified with proximal locking aperture in TFNA which can be related to the new design which had Substantial reduction in lateral thickness at compression screw aperture


Abstract. Introduction. Cementless fixation of Oxford Unicompartmental Knee Replacements (UKRs) is an alternative to cemented fixation, however, it is unknown whether cementless fixation is as good long-term. This study aimed to compare primary and long-term fixation of cemented and cementless Oxford UKRs using radiostereometric analysis (RSA). Methodology. Twenty-nine patients were randomised to receive cemented or cementless Oxford UKRs and followed for ten years. Differences in primary fixation and long-term fixation of the tibial components (inferred from 0/3/6-month and 6-month/1-year/2-year/5-year/10-year migration, respectively) were analysed using RSA and radiolucencies were assessed on radiographs. Migration rates were determined by linear regression and clinical outcomes measured using the Oxford Knee Score (OKS). Results. Preliminary analysis of Maximum Total Point Motion (MTPM) indicated cementless tibial components undergo significantly more migration than cemented components during the first 6 months (1.6mm/year, SD=0.92 versus 1.3mm/year, SD=1.1, p<0.001). Cementless migration was predominantly subsidence inferiorly (Mean=0.51mm/year, SD=0.29, p<0.001) and posteriorly (0.13mm/year, SD=0.21, p=0.03). Contrastingly, from 6 months to 10 years cemented components migrated significantly (MTPM=0.039mm/year, SD=0.11, p=0.04) whereas cementless components did not (MTPM=0.002mm/year, SD=0.02, p=0.744). Radiolucent lines occurred more frequently below cemented (10/13) than cementless (4/16) tibial components, but radiolucencies did not correlate with differences in migration or OKS. There was no significant difference in OKS between cemented and cementless. Conclusion. These results suggest that cementless tibial components migrate more than cemented before achieving primary fixation. However, long-term fixation of cementless tibial components appears to be as good, if not better, than cemented with the benefit of fewer radiolucent lines


Bone & Joint Research
Vol. 9, Issue 7 | Pages 386 - 393
1 Jul 2020
Doyle R van Arkel RJ Muirhead-Allwood S Jeffers JRT

Aims. Cementless acetabular components rely on press-fit fixation for initial stability. In certain cases, initial stability is more difficult to obtain (such as during revision). No current study evaluates how a surgeon’s impaction technique (mallet mass, mallet velocity, and number of strikes) may affect component fixation. This study seeks to answer the following research questions: 1) how does impaction technique affect a) bone strain generation and deterioration (and hence implant stability) and b) seating in different density bones?; and 2) can an impaction technique be recommended to minimize risk of implant loosening while ensuring seating of the acetabular component?. Methods. A custom drop tower was used to simulate surgical strikes seating acetabular components into synthetic bone. Strike velocity and drop mass were varied. Synthetic bone strain was measured using strain gauges and stability was assessed via push-out tests. Polar gap was measured using optical trackers. Results. A phenomenon of strain deterioration was identified if an excessive number of strikes was used to seat a component. This effect was most pronounced in low-density bone at high strike velocities. Polar gap was reduced with increasing strike mass and velocity. Conclusion. A high mallet mass with low strike velocity resulted in satisfactory implant stability and polar gap, while minimizing the risk of losing stability due to over-striking. Extreme caution not to over-strike must be exercised when using high velocity strikes in low-density bone for any mallet mass. Cite this article: Bone Joint Res 2020;9(7):386–393


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 58 - 58
23 Feb 2023
Rahardja R Love H Clatworthy M Young S
Full Access

The optimal method of tibial fixation when using a hamstring tendon autograft in anterior cruciate ligament (ACL) reconstruction is unclear. This study aimed to compare the risk of revision ACL reconstruction between suspensory and interference devices on the tibial side. Prospective data on primary ACL reconstructions recorded in the New Zealand ACL Registry between April 2014 and December 2019 were analyzed. Only patients with a hamstring tendon autograft fixed with a suspensory device on the femoral side were included. The rate of revision ACL reconstruction was compared between suspensory and interference devices on the tibial side. Univariate Chi-Square test and multivariate Cox regression was performed to compute hazard ratios (HR) and 95% confidence intervals (CI) with adjustment for age, gender, time-to-surgery, activity at the time of injury, number of graft strands and graft diameter. 6145 cases were analyzed, of which 59.6% were fixed with a suspensory device on the tibial side (n = 3662), 17.6% fixed with an interference screw with a sheath (n = 1079) and 22.8% fixed with an interference screw without a sheath (n = 1404). When compared to suspensory devices (revision rate = 3.4%), a higher risk of revision was observed when using an interference screw with a sheath (revision rate = 6.2%, adjusted HR = 2.05, 95% CI 1.20 – 3.52, p = 0.009) and without a sheath (revision rate = 4.6%, adjusted HR = 1.81, 95% CI 1.02 – 3.23, p = 0.044). The number of graft strands and a graft diameter of ≥8 mm did not influence the risk of revision. When reconstructing the ACL with a hamstring tendon autograft, the use of an interference screw, with or without a sheath, on the tibial side has a higher risk of revision when compared to a suspensory device


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 38 - 38
23 Feb 2023
Ernstbrunner L Almond M Rupasinghe H Jo O Zbeda R Ackland D Ek E
Full Access

The extracortical single-button (SB) inlay repair is one of the most preferred distal biceps tendon repair techniques. However, specific complications such as neurovascular injury and non-anatomic repairs have led to the development of techniques that utilize intracortical double-button (DB) fixation. To compare the biomechanical stability of the extracortical SB repair with the anatomical DB repair technique. Controlled laboratory study. The distal biceps tendon was transected in 18 cadaveric elbows from 9 donors. One elbow of each donor was randomly assigned to the extracortical SBor anatomical DB group. Both groups were cyclically loaded with 60N over 1000 cycles between 90° of flexion and full extension. The elbow was then fixed in 90° of flexion and the repair construct loaded to failure. Gap-formation and construct stiffness during cyclic loading, and ultimate load to failure was analysed. After 1000 cycles, the anatomical DB technique compared with the extracortical SB technique showed significantly less gap-formation (mean difference 1.2 mm; p=0.017) and significantly more construct stiffness (mean difference 31 N/mm; p=0.023). Ultimate load to failure was not significantly different comparing both groups (SB, 277 N ±92 vs. DB, 285 N ±135; p=0.859). The failure mode in the anatomical DB group was significantly different compared with the extracortical SB technique (p=0.002) and was due to fracture avulsion of the BicepsButton in 7 out of 9 specimens (vs. none in SB group). Our study shows that the intracortical DB technique produces equivalent or superior biomechanical performance to the SB technique. The DB repair technique reduces the risk of nerve injury and better restores the anatomical footprint of biceps tendon. The DB technique may offer a clinically viable alternative to the SB repair technique


Bone & Joint Research
Vol. 13, Issue 10 | Pages 559 - 572
8 Oct 2024
Wu W Zhao Z Wang Y Liu M Zhu G Li L

Aims. This study aimed to demonstrate the promoting effect of elastic fixation on fracture, and further explore its mechanism at the gene and protein expression levels. Methods. A closed tibial fracture model was established using 12 male Japanese white rabbits, and divided into elastic and stiff fixation groups based on different fixation methods. Two weeks after the operation, a radiograph and pathological examination of callus tissue were used to evaluate fracture healing. Then, the differentially expressed proteins (DEPs) were examined in the callus using proteomics. Finally, in vitro cell experiments were conducted to investigate hub proteins involved in this process. Results. Mean callus volume was larger in the elastic fixation group (1,755 mm. 3. (standard error of the mean (SEM) 297)) than in the stiff fixation group (258 mm. 3. (SEM 65)). Pathological observation found that the expression levels of osterix (OSX), collagen, type I, alpha 1 (COL1α1), and alkaline phosphatase (ALP) in the callus of the elastic fixation group were higher than those of the stiff fixation group. The protein sequence of the callus revealed 199 DEPs, 124 of which were highly expressed in the elastic fixation group. In the in vitro study, it was observed that a stress of 200 g led to upregulation of thrombospondin 1 (THBS1) and osteoglycin (OGN) expression in bone marrow mesenchymal stem cells (BMSCs). Additionally, these genes were found to be upregulated during the osteogenic differentiation process of the BMSCs. Conclusion. Elastic fixation can promote fracture healing and osteoblast differentiation in callus, and the ability of elastic fixation to promote osteogenic differentiation of BMSCs may be achieved by upregulating genes such as THBS1 and OGN. Cite this article: Bone Joint Res 2024;13(10):559–572


Bone & Joint Open
Vol. 3, Issue 7 | Pages 566 - 572
18 Jul 2022
Oliver WM Molyneux SG White TO Clement ND Duckworth AD

Aims. The primary aim was to estimate the cost-effectiveness of routine operative fixation for all patients with humeral shaft fractures. The secondary aim was to estimate the health economic implications of using a Radiographic Union Score for HUmeral fractures (RUSHU) of < 8 to facilitate selective fixation for patients at risk of nonunion. Methods. From 2008 to 2017, 215 patients (mean age 57 yrs (17 to 18), 61% female (n = 130/215)) with a nonoperatively managed humeral diaphyseal fracture were retrospectively identified. Union was achieved in 77% (n = 165/215) after initial nonoperative management, with 23% (n = 50/215) uniting after surgery for nonunion. The EuroQol five-dimension three-level health index (EQ-5D-3L) was obtained via postal survey. Multiple regression was used to determine the independent influence of patient, injury, and management factors upon the EQ-5D-3L. An incremental cost-effectiveness ratio (ICER) of < £20,000 per quality-adjusted life-year (QALY) gained was considered cost-effective. Results. At a mean of 5.4 yrs (1.2 to 11.0), the mean EQ-5D-3L was 0.736 (95% confidence interval (CI) 0.697 to 0.775). Adjusted analysis demonstrated the EQ-5D-3L was inferior among patients who united after nonunion surgery (β = 0.103; p = 0.032). Offering routine fixation to all patients to reduce the rate of nonunion would be associated with increased treatment costs of £1,542/patient, but would confer a potential EQ-5D-3L benefit of 0.120/patient over the study period. The ICER of routine fixation was £12,850/QALY gained. Selective fixation based on a RUSHU < 8 at six weeks post-injury would be associated with reduced treatment costs (£415/patient), and would confer a potential EQ-5D-3L benefit of 0.335 per ‘at-risk patient’. Conclusion. Routine fixation for patients with humeral shaft fractures to reduce the rate of nonunion observed after nonoperative management appears to be a cost-effective intervention at five years post-injury. Selective fixation for patients at risk of nonunion based on their RUSHU may confer even greater cost-effectiveness, given the potential savings and improvement in health-related quality of life. Cite this article: Bone Jt Open 2022;3(7):566–572


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 8 - 8
10 Jun 2024
Airey G Aamir J Chapman J Tanaka H Elbannan M Singh A Mangwani J Kyaw H Jeyaseelan L Mason L
Full Access

Background. Research on midfoot injuries have primarily concentrated on the central column and the Lisfranc ligament without amassing evidence on lateral column injuries. Lateral column injuries have historically been treated with Kirschner wire fixation when encountered. Objective. Our aim in this study was to analyse lateral column injuries to the midfoot, their method of treatment and the radiological lateral column outcomes. Our nul hypothesis being that fixation is required to obtain and maintain lateral column alignment. Methods. Data was retrospectively collected from four centres on surgically treated midfoot fracture dislocations between 2011 and 2021. Radiographs were analysed using departmental PACS. All statistics was performed using SPSS 26. Results. A total of 235 cases were diagnosed as having a lateral column injury out of the 409 cases included. On cross tabulation, there was a significant association with having a central column injury (234/235, p<.001) and 70% of cases (166/235) also had an additional medial column injury. Of the 235 lateral column injuries, data was available regarding fixation radiographic alignment on 222 cases. There were 44 cases which underwent Kirschner wire fixation, 23 plate fixations and 3 screw fixations. Lateral column alignment loss was seen in 2.84% (4/141) of those which didn't undergo fixation, 13.64% (6/44) which underwent K wires, and 0 % in those fixed by screws or K wires. Conclusion. Lateral column injury occurs in over half of midfoot fractures in this study. It rarely occurs alone and is most commonly related to three column injuries. Nevertheless, following stabilisation of the central column, additional fixation of injuries to the lateral column do not appear beneficial. The use of a bridge plate to fix the central column appears protective and purely ligamentous injury was a higher risk than an injury that included the bone


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 40 - 40
10 May 2024
Zhang J Miller R Chuang T
Full Access

Introduction. Distal femur fractures have traditionally been stabilized with either lateral locking plate or retrograde intramedullary nail. Dual-plates and nail-plate combination fixation have the theoretical biomechanical advantage, faster union and allows patients to weight bear immediately. The aim of this study is to compare single vs combination fixation, and evaluate outcomes and complications. Method. We retrospectively reviewed all patients over 60, admitted to Christchurch Hospital, between 1st Jan 2016 and 31st Dec 2022, with an AO 33A/33B/33C distal femur fracture. Patient demographics, fracture characteristics, operation details, and follow up data were recorded. Primary outcomes are union rate, ambulatory status at discharge, and surgical complications. Secondary outcomes include quality of reduction, operation time and rate of blood transfusions. Results. 114 patients were included. (92 single fixation, 22 combination fixation). Baseline demographic data and fracture characteristics did not differ between the cohorts. There was no difference in the rate of union or time to union between the two cohorts. Combination fixation patients were allowed to weight-bear as tolerated significantly more than single fixation patients (50% vs 18.9%, p=0.003). There was no difference in length of hospital stay, transfusion, complication and mortality rates. Medial translation of the distal articular block was significantly lower in the combination fixation cohort (1.2% vs 3.4%, p=0.021). Operation time was significantly longer in the combination fixation cohort (183mins vs 134mins, p<0.001). Discussion. The results show no difference in achieving union or time to union, despite better quality of fracture reduction with dual fixation. This differs to previously published literature. The clear benefit of combination fixation is immediate weight-bearing. As expected, operation times were longer with combination fixation, however this did not translate to more complications. Conclusion. Combination fixation allows earlier weight bearing, at the cost of longer operation times


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 7 - 7
1 Dec 2022
Nowak L Moktar J Henry P Schemitsch EH
Full Access

This study aimed to determine if multiple failed closed reductions (CRs) prior to fixation of distal radius fracture is associated with the odds of complication-related reoperation up to two years post fracture. We identified all distal radius fracture patients aged 18 or older between the years of 2003-2016 in Ontario, Canada from linked administrative databases. We used procedural and fee codes to identify patients who underwent primary outpatient surgical fixation between 8 and 14 days post fracture, and grouped patients by the number of CRs they underwent prior to definitive fixation. We excluded patients who underwent fixation within 7 days of their fracture to exclude more complex fracture types and/or patients who required more immediate surgery. We grouped patients according to the number of CRs they underwent prior to definitive fixation. We used intervention and diagnostic codes to identify reoperations within two years of fixation. We used multi-level multivariable logistic regression to compare the association between the number of CRs and reoperation while accounting for clustering at the surgeon level and adjusting for other relevant covariables. We performed an age-stratified analysis to determine if the association between the number of CRs and reoperation differed by patient age. We identified 5,464 patients with distal radius fractures managed with outpatient fixation between 8 and 14 days of their fracture. A total of 1,422 patients (26.0%) underwent primary surgical fixation (mean time to fixation 10.6±2.0 days), while 3,573 (65.4%) underwent secondary fixation following one failed CR (mean time to fixation 10.1±2.2 days, time to CR 0.3±1.2 days), and 469 (8.6%) underwent fixation following two failed CRs (mean time to fixation 10.8±2.2 days, time to first CR 0.0±0.1 days, time to second CR 4.7±3.0 days). The CR groups had higher proportions of female patients compared to the primary group, and patients who underwent two failed CRs were more likely to be fixed with a plate (vs. wires or pins). The unadjusted proportion of reoperations was significantly higher in the group who underwent two failed CRs (7.5%) compared to those who underwent primary fixation (4.4%), and fixation following one failed CR (4.9%). Following covariable adjustment, patients who underwent two failed CRs had a significantly higher odds of reoperation (odds ratio [OR] 1.72 [1.12-2.65]) compared to those who underwent primary fixation. This association appeared to worsen for patients over the age of 60 (OR 3.93 [1.76-8.77]). We found no significant difference between the odds of reoperation between patients who underwent primary fixation vs. secondary fixation following one failed CR. We found that patients with distal radius fractures who undergo multiple CRs prior to definitive fixation have a significantly higher odds of reoperation compared to those who undergo primary fixation, or fixation following a single CR. This suggests that surgeons should offer fixation if indicated following a single failed CR rather than attempt multiple closed reductions. Prospective studies are required to confirm these findings


Bone & Joint Open
Vol. 5, Issue 3 | Pages 154 - 161
1 Mar 2024
Homma Y Zhuang X Watari T Hayashi K Baba T Kamath A Ishijima M

Aims. It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA. Methods. In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound. Results. The median sound pressure (SP) of successful fixation at 0.5 to 1.0 kHz was higher than that of unsuccessful fixation (0.0694 (interquartile range (IQR) 0.04721 to 0.09576) vs 0.05425 (IQR 0.03047 to 0.06803), p < 0.001). The median SP of successful fixation at 3.5 to 4.0 kHz and 4.0 to 4.5 kHz was lower than that of unsuccessful fixation (0.0812 (IQR 0.05631 to 0.01161) vs 0.1233 (IQR 0.0730 to 0.1449), p < 0.001; and 0.0891 (IQR 0.0526 to 0.0891) vs 0.0885 (IQR 0.0716 to 0.1048); p < 0.001, respectively). There was a statistically significant positive relationship between body weight and SP at 0.5 to 1.0 kHz (p < 0.001). Multivariate analyses indicated that the SP at 0.5 to 1.0 kHz and 3.5 to 4.0 kHz was independently associated with the successful fixation. Conclusion. The frequency bands of 0.5 to 1.0 and 3.5 to 4.0 kHz were the key to distinguish the sound characteristics between successful and unsuccessful press-fit cup fixation. Cite this article: Bone Jt Open 2024;5(3):154–161


Bone & Joint Open
Vol. 4, Issue 3 | Pages 154 - 161
28 Mar 2023
Homma Y Zhuang X Watari T Hayashi K Baba T Kamath A Ishijima M

Aims. It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA. Methods. In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound. Results. The median sound pressure (SP) of successful fixation at 0.5 to 1.0 kHz was higher than that of unsuccessful fixation (0.0694 (interquartile range (IQR) 0.04721 to 0.09576) vs 0.05425 (IQR 0.03047 to 0.06803), p < 0.001). The median SP of successful fixation at 3.5 to 4.0 kHz and 4.0 to 4.5 kHz was lower than that of unsuccessful fixation (0.0812 (IQR 0.05631 to 0.01161) vs 0.1233 (IQR 0.0730 to 0.1449), p < 0.001; and 0.0891 (IQR 0.0526 to 0.0891) vs 0.0885 (IQR 0.0716 to 0.1048); p < 0.001, respectively). There was a statistically significant positive relationship between body weight and SP at 0.5 to 1.0 kHz (p < 0.001). Multivariate analyses indicated that the SP at 0.5 to 1.0 kHz and 3.5 to 4.0 kHz was independently associated with the successful fixation. Conclusion. The frequency bands of 0.5 to 1.0 and 3.5 to 4.0 kHz were the key to distinguish the sound characteristics between successful and unsuccessful press-fit cup fixation. Cite this article: Bone Jt Open 2024;4(3):154–161


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 58 - 58
17 Nov 2023
Huang D Buchanan F Clarke S
Full Access

Abstract. Objectives. Osteoporotic fractures tend to be more challenging than fractures in healthy bone and the efficacy of metal screw fixation decreases with decreasing bone mineral density making it more difficult for such screws to gain purchase. This leads to increased complication rates such as malunion, non-union and implant failure (1). Bioresorbable polymer devices have seen clinical success in fracture fixation and are a promising alternative for metallic devices but are rarely used in the osteoporotic population. To address this, we are developing a system that may allow osteoporotic patients to avail of bioresorbable devices (2) but it is important to establish if patients have any reservations about having a plastic resorbable device instead of a metal one. Therefore the aim of this study was to explore the acceptability of bioresorbable fracture fixation devices to people with osteoporosis. Methods. A cross sectional descriptive study was conducted in a UK wide population using convenience sampling. An online survey comprising nine survey questions and nine demographic questions was developed in Microsoft Teams and tested for face validity in a small pilot study (n=6). Following amendments and ethical approval, the survey was distributed by the Royal Osteoporosis Society on their website and social media platforms. People were invited to take part if they lived in the UK, were over 18 years old and had been diagnosed with osteoporosis. The survey was open for three weeks in May 2023. Responses were analysed using descriptive statistics. Results. There were 112 responses. Eight participants had not been diagnosed with osteoporosis and therefore did not meet the study criteria. Of the remaining 104, 102 were female and 2 were male and 102 were white (2 chose not to disclose their ethnicity). The majority of participants were aged 55–64 (34.6%) or 65–74 (37.5%), were college/university educated (38.5%) and had previously sustained a fragility fracture (52.9%). Only 3.9% of participants had heard of bioresorbable fracture fixation devices compared to 62.5% for metal devices. Most people were unsure if they would trust one type of device over the other (58.7%) and would ask for more information if their surgeon were to suggest using a bioresorbable device to fix their fracture (61.5%). The most commonly reported concerns were about device safety and efficacy: toxicity of the degradation products and the device breaking down too early before the fracture had healed. Two participants cited environmental concerns about increased use of plastics as a reason they would decline such a device. Conclusions. As expected, participants had little to no knowledge of bioresorbable polymer fixation devices. In general, they were willing to be guided by their surgeon but would require supporting information on the safety and efficacy of their long-term use. The results of this study show that it will be important to have relevant and understandable information to give patients when recommending these devices as treatments to ensure and support a shared-decision approach to patient care. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project