The use of contoured side plate screw attached to the sliding screw plate anchors the comminuted fragments thus gives better stability, compression, early mobility and bony union to this fracture where other implant fails.
The side plate is a narrow D.C.P. (4/5 hole) which is contoured to the fl are of greater trochanter proximally and is attached to the sliding screw plate. The proximal holes of side plate hold the comminuted fragment of greater trochanter with cancellous screw above the sliding hip screw The patient were encouraged to walk on 2nd post operative day with support to start with partial weight bearing followed by weight bearing at 4 wk.
Coronoid fractures account for 2 to 15% of the cases with elbow dislocations and usually occur as part of complex injuries.
The management of comminuted metaphyseal fractures is a technical challenge and satisfactory outcomes of such fixations often remain elusive. The small articular fragments and bone loss often make it difficult for standard fixation implants for proper fixation. We developed a novel technique to achieve anatomical reduction in multiple cases of comminuted metaphyseal fractures at different sites by employing the cantilever mechanism with the help of multiple thin Kirschner wires augmented by standard fixation implants. We performed a retrospective study of 10 patients with different metaphyseal fractures complicated by comminution and loss of bone stock. All patients were treated with the help of cantilever mechanism using multiple Kirschner wires augmented by compression plates. All the patients were operated by the same surgeon between November 2020 to March 2021 and followed up till March 2023. Surgical outcomes were evaluated according to the clinical and radiological criteria. A total of 10 patients were included in the study. Since we only included patients with highly unstable and comminuted fractures which were difficult to fix with traditional methods, the number of patients in the study were less. All 10 patients showed satisfactory clinical and radiological union at the end of the study with good range of motion. One of the patient in the study had post-operative wound complication which was managed conservatively with regular dressings and oral antibiotics.
Background.
Seventy-eight children, with 79 femoral fractures, treated with titanium elastic intramedullary nails were reviewed for complications. Insertion site symptoms (41), malunion (8), refracture (2), transient neurological deficit (2), superficial wound infection (2), and reoperation prior to union (10). Malunion/loss of reduction was increased with mismatched nails (p=0.02) and comminution (p=0.02). Insertion site symptoms were increased with nail ends that were bent (p=0.02), or >
10mm prominent (p=0.002). Nails remain implanted in 25 children without problems. Nail ends should lie against the femur to avoid insertion site symptoms. Nails of different diameters should not be implanted.
Background. Leg length discrepancy (LLD) after intramedullary nailing of femoral shaft fractures is a common problem reported in up to 43% of cases.
Our Purpose is to present the results of treatment of 35 (thirty five) comminuted fractures of the diaphyses of Tibia and Fibula with combination of Orthofix External Fixator and Sarmiento Brace. In Syros General Hospital, during the last 8 (eight) years, 35 (thirty five) comminuted fractures of the Diaphyses of Tibia and Fibula were treated. Twenty were closed and 15 (fifteen) compound. Five were type 1, 8 (eight) type 2 and 2 type 3 Gustilo. Our Method : After a good surgical cleaning all fractures were reduced and stabilized with Orthofix External Fixator. We used two pins above and two pins below the fracture. According to the union of the fracture, we allowed partial weight bearing with dynamization. In three months the External Fixator was removed and a Sarmiento Brace was put. With the Brace we allowed full weight bearing until the fracture was united. Results: All fractures united. It took five months for the close and six months for the compound. There was no displacement in any fracture. In four fractures we had pin infection that was cured with antibiotics and lack of weight bearing for 15 days. Conclusion :
Purpose: To calculate a clinically relevant and intra-operatively accessible measure of olecranon length that could be reliably applied by the operating surgeon to optimise comminuted olecranon fracture fixation. Materials: One hundred normal adult anteroposterior and lateral radiographs of the elbow were studied with respect to the proximal olecranon width (OW), greater sigmoid notch width (SW) on lateral views, trans-epicondylar distance (TED), and trochlear width distance (TWD) on AP views. The mean ratios of TWD/SW and TED/SW and an index OW X SW/TED along with their standard deviation and normal ranges were calculated. Results: The average olecranon width was 24mm (range 21mm–28mm), sigmoid width was 25.8 mm (range 21mm–32 mm), trans-epicondylar distance was 58.53mm (range 49mm–74 mm), and the trochlear width distance was 27.1mm (range 22mm–32 mm). The average ratio of TWD: SW was 1.05 with a standard deviation of 0.09 and that of TED: SW was 2.27 with a standard deviation of 0.19. The average index worked out to be 10.58 with a standard deviation of 0.2. Conclusions:
Treatment of comminuted intraarticular calcaneal fractures remains controversial and challenging. Anatomic reduction with stable fixation has demonstrated better outcomes than nonoperative treatment of displaced intraarticular fractures involving the posterior facet and anterior calcaneocuboid joint (CCJ) articulating surface of the calcaneus. The aim of this study was to investigate the biomechanical performance of three different methods for fixation of comminuted intraarticular calcaneal
Aim: To assess the clinical and functional outcome of proximal humeral fractures (2,3 and 4 parts) fixation with PHILOS (Proximal Humeral interlocked Osteosynthesis) plate using Oxford and DASH scoring system. Methods: Forty-eight consecutive patients were treated with PHILOS plate from the complex proximal humeral fractures. One senior surgeon, using PHILOS plates, operated all patients. The patients were regularly assessed clinically, and plain radiographic evaluation was performed for fracture healing, avascular necrosis, and implant failure. Clinical outcome was measured using Oxford shoulder scores and DASH (Disability of the arm, shoulder, and hand) scores. Patients, who died, lost the follow up or the follow up was less than 3 months were excluded from the study. Results: There were nine male patients (Age: 29–89 yrs) and twenty-nine female patients (Age: 35–93 yrs). Average age: 65 yrs. 74% were two part and three part fractures. Five patients died and four were lost in follow-up. These patients were excluded from the study. Mean follow-up time: 21.7 months (range: 6–44 months). Mean oxford shoulder scores: 41.8 (range: 14–60), Mean DASH scores: 30.2 (range: 0–83.3). There were no cases of non-union. Two plates were removed after fracture healing for complications of impingement and screw cutout. Discussion &
conclusion: Proximal humeral fractures constitute 5–7% of all fractures and 26% of humeral fractures.13–16% of proximal humeral fractures are 3 &
4 parts. Proximal humeral fractures have been a challenge to acquire stable fixation. Difficulties have been multifactorial, including osteoporotic bone, angular instability and non-availability of the low-profile implant to avoid impingements. PHILOS plate having locking screws provides angular stability and better hold in osteoporotic bone. It is low profile, which avoids subacromial impingement. Multiple holes in the proximal part of plate for suture anchors helps for soft tissue augmentation. PHILOS plate can provide an excellent stable construct even in multifragmented Osteoporotic proximal humeral fractures. Our study has shown that PHILOS plates are reliable implants for internal fixation of proximal humerus fractures. An inverse correlation was seen between oxford shoulder scores and DASH scores. Patients with higher oxford scores indicating a good outcome had lesser disability scores.
Low-energy distal radius fractures (DRFs) are the most common upper arm fractures correlated with bone fragility. Vitamin D deficiency is an important risk factor associated with DRFs. However, the relationship between DRF severity and vitamin D deficiency is not elucidated. Therefore, this study aimed to identify the correlation between DRF severity and serum 25-hydroxyvitamin-D level, which is an indicator of vitamin D deficiency. This multicentre retrospective observational study enrolled 122 female patients aged over 45 years with DRFs with extension deformity. DRF severity was assessed by three independent examiners using 3D CT. Moreover, it was categorized based on the AO classification, and the degree of articular and volar cortex comminution was evaluated. Articular comminution was defined as an articular fragment involving three or more fragments, and volar cortex comminution as a fracture in the volar cortex of the distal fragment. Serum 25-hydroxyvitamin-D level, bone metabolic markers, and bone mineral density (BMD) at the lumbar spine, hip, and wrist were evaluated six months after injury. According to DRF severity, serum 25-hydroxyvitamin-D level, parameters correlated with bone metabolism, and BMD was compared.Aims
Methods
Background.
Introduction.
This cohort study reports outcomes of patients with comminuted radial head fractures treated with a modular radial head arthroplasty. Twenty-six patients (mean age = fifty-four) were prospectively followed at three, six, twelve, and twenty-four months following surgery. Patient satisfaction with this procedure was high. This data indicates favorable results using a modular radial head arthroplasty with rapid improvement in disability and physical impairment occurring in all measures in the first six months and further improvement in most patients up to two years. The Mayo Elbow Performance Index was at one year and eighty-four at two years. To investigate the objective and subjective outcomes of unreconstructable radial head fractures treated with a modular radial head arthroplasty. This data indicates favorable results using a modular radial head arthroplasty with improvement in satisfaction, disability and physical impairment occurring in all measures in the first six-months and continued improvement for up to two-years.
Introduction
The paradoxical migration of the femoral neck element (FNE) superomedially against gravity, with respect to the intramedullary component of the cephalomedullary device, is a poorly understood phenomenon increasingly seen in the management of pertrochanteric hip fractures with the intramedullary nail. The aim of this study was to investigate the role of bidirectional loading on the medial migration phenomenon, based on unique wear patterns seen on scanning electron microscopy of retrieved implants suggestive of FNE toggling. A total of 18 synthetic femurs (Sawbones, Vashon Island, Washington) with comminuted pertrochanteric fractures were divided into three groups (n = 6 per group). Fracture fixation was performed using the Proximal Femoral Nail Antirotation (PFNA) implant (Synthes, Oberdorf, Switzerland; n = 6). Group 1 was subjected to unidirectional compression loading (600 N), with an elastomer (70A durometer) replacing loose fracture fragments to simulate surrounding soft-tissue tensioning. Group 2 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading), also with the elastomer replacing loose fracture fragments. Group 3 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading) without the elastomer. All constructs were tested at 2 Hz for 5000 cycles or until cut-out occurred. The medial migration distance (MMD) was recorded at the end of the testing cycles.Objectives
Methods
A successful outcome following treatment of nonunion requires the correct identification of all of the underlying cause(s) and addressing them appropriately. The aim of this study was to assess the distribution and frequency of causative factors in a consecutive cohort of nonunion patients in order to optimise the management strategy for individual patients presenting with nonunion. Causes of the nonunion were divided into four categories: mechanical; infection; dead bone with a gap; and host. Prospective and retrospective data of 100 consecutive patients who had undergone surgery for long bone fracture nonunion were analysed.Objectives
Methods