Advertisement for orthosearch.org.uk
Results 1 - 20 of 140
Results per page:
Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 539 - 539
1 Aug 2008
Shah NN Wijeratna M Bistiadou M Fordyce MJF Skinner PW
Full Access

Introduction: The hip resurfacing in younger patients is being performed more frequently in the UK. At the same time conventional Total Hip Replacement (THR) is also being performed.. We carried out a study to compare the patient satisfaction and outcome following Birmingham Hip Resurfacing (BHR) and Total Hip Replacement (THR) in patients below the age of 55 years. Methods: There were 93 BHR in 73 patients and 74 THR in 64 patients performed between February 1997 to June 2005.. Retrospective evaluation of notes and complications were identified. We carried out our study using Oxford Hip score and Modified WOMAC questionnaire by postal and telephonic survey. Results: We found that mean length of stay was 4.5 days for BHR and 6.4 days for THR patients. (P< 0.0001) The dislocation rate was 0% for BHR as oppose to 4% for THR. (P< 0.05) The mean Oxford Hip score improved from pre-operative 43 to 14 for BHR as oppose to 48 to 22 for THR patients. The mean modified WOMAC score improved from 21 to 8.4 for BHR as oppose to 25 pre-operative score to 12 for THR. We also found early and sustained improvement in these scores for BHR as compare to THR during their follow-up within 6 months to 8 years. The improvement in pain score was 100% following BHR as opposed to 84% for THR. Following BHR 70% patients were very active or active as oppose to only 30% of THR patients. Return to the work and sporting activities following BHR was at a mean of 9 weeks as oppose to 14 weeks following THR. (P < 0.05) The level of satisfaction was 98% following BHR as oppose to 84% following THR. (P=0.356)


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 552 - 553
1 Aug 2008
Lee SM Kinbrum A Vassiliou K Kamali A Unsworth A
Full Access

Introduction: The Birmingham Hip Resurfacing (BHR) system comprises both a BHR femoral head and a large modular femoral head for use should a total hip replacement be required. The modular femoral head has identical material chemistry, microstructure, spherical form, and surface roughness of the bearing surfaces of resurfacing femoral head and both BHR and THR devices share the same acetabular components. Hence, if the femoral component of a BHR needs revision surgery, the Birmingham hip system provides the potential of converting it to a THR without the need to also revise the well fixed cup. Although it stands to reason that the wear behaviour of the BHR and Birmingham THR will be similar, it is important to investigate the wear behaviour of new THR modular heads against worn BHR cups, representing revision of BHR to Birmingham THR without cup revision. The aim of this study is to assess the viability of the femoral component revision for BHR devices whilst leaving the acetabular components in situ in the pelvis. Materials and Methods: The wear and friction tests were conducted with pristine modular heads paired with BHR cups which had already undergone 5 million cycles (Mc) of wear in a hip simulator against BHR heads. Results and Discussions: The average wear rate of the new Birmingham THR modular heads against worn cups was 0.42 mm. 3. /Mc whilst the new BHR heads against new cups generated wear rate of 0.67 mm. 3. /Mc. Supported by the friction test results, it indicated that the new femoral heads paired with worn cup did not negatively affect the substantial amount of fluid-film lubrication that had developed over the course of the original test. Therefore, it is acceptable to use new femoral heads against worn cups, if the cups are not damaged, well fixed and correctly orientated


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 17 - 17
1 Dec 2013
Bolland B Gardner E Roques A Maul C Culliford D Zeineh N O'Hara L
Full Access

This study reports the mid-term results of a large bearing uncemented metal on metal total hip replacement (MOMHTHR) matched series using the Synergy stem and Birmingham modular head in 36 hips (mean follow up 61 months). All patients underwent clinical, metal ion and MRI assessment. Wear analysis was performed on retrieved heads using Redlux non-contact optical profilometry. Seven patients (19%) have undergone revision surgery. All revisions had two or more of either symptoms, high metal ions or an MRI suggestive of an adverse reaction to metal debris (ARMD). There was no evidence of component malposition or impingement. Frank staining of tissues together with high volume dark brown fluid collections were found in all cases. All stems and cups were well fixed. In 4 cases pubic and ischial lysis (adjacent to the inferior fins) was observed. All 7 cases had radiological, intraoperative and histological evidence of ARMD (Figure 1). The failure cohort had significantly higher whole blood cobalt ion levels and OHS (p = 0.001), but no significant difference in cup size (p = 0.77), gender predominance, stem offset or cup position (p = 0.12). Sleeves had been used in all revision cases. Wear analysis (n = 4) demonstrated increased wear at the trunnion/sleeve interface in a distribution compatible with micromotion (Figure 2). There was normal wear at the articulating surface. This series further demonstrates unacceptable failure rates in LHMOMTHR in a series where a compatible stem for the BHR modular head was used. Use of a CoCr sleeve within a CoCr head taper appears to contribute to abnormal wear and therefore potential ARMD and subsequent failure


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 512 - 512
1 Oct 2010
Corten K Bartels W Bellemans J Broos P Meermans G Simon J Vander Sloten J
Full Access

Aim: Component positioning may be adversely affected by minimally invasive approach in total hip replacement due to restricted visualization. Problems with proper alignement are suggested to concern anteversion more than inclination and occur particulary in the lateral position.

Method: 53 patients were enrolled prospectively randomised to each group. First group (standard group, n= 30pts) underwent conventional total hip replacement in supine position and transgluteal approach and second group (MIS group, n= 23pts) underwent THR using minimally invasive anterior approach in lateral decubitus position Every group was operated on by two experienced senior surgeons. Desired cup position was 40°–45°inclination and 15–20° anteversion for the MIS group and 45°inclination and 15 ° anteversion for standard group. Postoperatively all patients had pelvic CT scan. Inclination and anteversion were determined by an independent observer using a 3-D model and planning software, the operative definition was used according to Murray.

Results: Mean inclination/anteversion in the MIS group was 39°(26°–50°)/25°(10°–47°), and 44°(29°–57°)/22°(1°–53°) within the standard group. Standard deviation for inclination was 7° for both groups, and 10° (MIS group) vs 14° (standard group) for anteversion.

The difference in the mean values regarding inclination was greater than would be expected by chance; there was a statistically significant difference (P = 0,010).

Discussion: In general cup positioning in both groups was less steep and more anteverted as presumed. The standard deviation for inclination was the same in both groups, but the standard deviation for anteversion was less in MIS group, that means less outliers regarding anteversion. Cup positioning in minimally invasive total hip replacement is safe compared to traditional approach.

Navigation technique was discussed to equalize the drawback of MIS. However, tools like imageless navigation may further improve the cup position even in traditional approach.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 39 - 39
19 Aug 2024
Zuke WA Hannon CP Kromka J Granger C Clohisy JC Barrack RL
Full Access

We previously reported the five to ten-year results of the Birmingham Hip Resurfacing (BHR) implant. The purpose of this study was to evaluate the survivorship, radiographic results, and clinical outcomes of the BHR at long-term follow-up. We retrospectively reviewed 250 patients from the original cohort of 324 BHRs performed from 2006 to 2013 who met contemporary BHR indications. Of these, 4 patients died and 4 withdrew. From the 242 patients, 224 patients (93%) were available for analysis. Modified Harris hip score (mHHS) and University of California, Los Angeles (UCLA) scores were collected and compared to a matched total hip arthroplasty (THA) cohort. Mean follow-up was 14 years. Survivorship free of aseptic revision was 97.4% and survivorship free of any revision was 96.0% at 15 years. Revisions included 3 periprosthetic joint infections, 2 for elevated metal ions and symptomatic pseudotumor, 2 for aseptic femoral loosening, and 1 for unexplained pain. The mean mHHS was 93 in BHR patients at final follow-up, similar to the THA cohort (p=0.44). The UCLA score was significantly higher for BHR patients (p=0.02), however there were equal proportions of patients who remained highly active (UCLA 9 or 10) in both groups, 60.5% and 52.2% (p=0.45) for BHR and THA respectively. Metal ion levels at long term follow-up were low (mean serum cobalt 1.8±1.5 ppb and mean serum chromium 2.2±2.0 ppb). BHR demonstrated excellent survivorship in males less than 60 years of age at time of surgery. Clinical outcomes and activity levels were similar to THA patients. Failures related to the metal-on-metal bearing were rare and metal levels were low at long-term follow-up. Level of evidence: III. Keywords: survivorship; hip arthroplasty; activity; metal-on-metal. Surface Replacement Arthroplasty demonstrates low revision rates and similar activity level compared to total hip arthroplasty at long-term follow-up


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 6 - 6
17 Apr 2023
Maslivec A Leon D Cobb J
Full Access

Reports of improved functional outcome of Metal on Metal Hip Resurfacing Arthroplasty (mHRA) to Total Hip Replacement needs to be balanced with concerns of metal ion release. By removing cobalt-chrome, cHRA reduces these risks. To the author's knowledge, there is no data available on functional outcomes of cHRA, therefore the aim of the study was to compare the function between cHRA patients and mHRA patients. 24 patients received a unilateral cHRA (H1, Embody) and was compared to 24 age and gender matched patients with a unilateral mHRA (BHR, Smith and Nephew). All patients completed the Oxford Hip Score (OHS)[T2] and underwent gait analysis on an instrumented treadmill before and at a mean of 74wks (+/− 10) for mHRA and 53wks (+/− 2) for cHRA post op. Walking trials started at 4km/h and increased in 0.5km/h increments until a top walking speed (TWS) was achieved. Vertical ground reaction forces (GRF) were recorded along with the symmetry index (SI). Spatiotemporal measures of gait were also recorded. Vertical GRF were captured for the entire normalised stance phase using statistical parametric mapping (SPM; CI = 95%). The gain in OHS was similar: H1 (25-46), BHR(27-47). TWS increased by 19% with H1 (6.02 – 8.0km/hr), and 20% with BHR (6.02 – 7.37km/hr). SPM of the entire gait cycle illustrated the restoration of symmetry in both groups with no difference in GRF across the stance phase between groups at 5km/hr pre-op and post-op. At faster speeds (6.5km/hr), H1 patients had a mid-support GRF slightly closer to normal compared to BHR. Both groups increased step length similar from pre to post op (H1:0.76 – 0.85cm, BHR:0.77-0.86cm). In this study, subjective and objective functional outcome measures suggest that short term functional outcomes of ceramic resurfacing is not inferior to metal resurfacing


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 33 - 33
23 Jun 2023
Engh CA Bhal V Hopper RH
Full Access

When the Birmingham Hip Resurfacing (BHR) metal-on-metal implant system was approved by the United States Food and Drug Administration in 2006, a multicenter, prospective, post-approval study (PAS) was required. This study uses data from the PAS to investigate metal level and glomerular filtration rate (GFR) trends over the first decade in vivo. Between October 2006 and March 2011, 290 primary BHR procedures were performed among 262 patients at 5 sites. Whole blood samples were sent to a single specialized laboratory to determine GFR, cobalt (Co) and chromium (Cr) levels. The population for this study consists of 117 unrevised unilateral patients with a mean age at surgery of 51.3±6.5 years who had pre-operative, 1-year, 4-year, 5-year and 10-year laboratory data. The mean follow-up for these patients that included 36 females was 10.1±0.2 years. Median metal levels at 1-year increased relative to pre-operative values for Co (by a factor of 9.7 from 0.13 to 1.26 ppb, p<0.001) and Cr (by a factor of 2.5 from 0. 60 to 1.50 ppb, p<0.001). Metal levels subsequently remained relatively constant over time with a median 10-year value of 1.12 ppb for Co and 1.29 ppb for Cr. Based on 585 blood samples from all 117 patients, there was no relationship between GFR and Co (. →. =−0.06, p=0.14) or Cr (. →. =0.05, p=0.27) levels. However, lower pre-operative GFR values were associated with larger increases in Co at 1-year relative to the pre-operative level (. →. =−0.26, p=0.005). There was no relationship between pre-operative GFR values and changes in Cr at 1 year (. →. =−0.13, p=0.15). Through the first decade in vivo, elevated whole blood metal levels for unilateral BHR patients do not appear to adversely affect GFR. However, patients with lower pre-operative GFR values tend to have larger increases in their Co level at 1-year


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 22 - 22
1 Dec 2022
Werle J Kearns S Bourget-Murray J Johnston K
Full Access

A concern of metal on metal hip resurfacing arthroplasty is long term exposure to Cobalt (Co) and Chromium (CR) wear debris from the bearing. This study compares whole blood metal ion levels from patients drawn at one-year following Birmingham Hip Resurfacing (BHR) to levels taken at a minimum 10-year follow-up. A retrospective chart review was conducted to identify all patients who underwent a BHR for osteoarthritis with a minimum 10-year follow-up. Whole blood metal ion levels were drawn at final follow-up in June 2019. These results were compared to values from patients with one-year metal ion levels. Of the 211 patients who received a BHR, 71 patients (54 males and 17 females) had long term metal ion levels assessed (mean follow-up 12.7 +/− 1.4 years). The mean Co and Cr levels for patients with unilateral BHRs (43 males and 13 females) were 3.12 ± 6.31 ug/L and 2.62 ± 2.69 ug/L, respectively, and 2.78 ± 1.02 ug/L and 1.83 ± 0.65 ug/L for patients with bilateral BHRs (11 males and 4 females). Thirty-five patients (27 male and 8 female) had metal-ion levels tested at one-year postoperatively. The mean changes in Co and Cr levels were 2.29 ug/l (p = 0.0919) and 0.57 (p = 0.1612), respectively, at one year compared to long-term. These changes were not statistically significant. This study reveals that whole blood metal ion levels do not change significantly when comparing one-year and ten-year Co and Cr levels. These ion levels appear to reach a steady state at one year. Our results also suggest that regular metal-ion testing as per current Medicines and Healthcare products Regulatory Agency (MHRA) guidelines may be impractical for asymptomatic patients. Metal-ion levels, in and of themselves, may in fact possess little utility in determining the risk of failure and should be paired with radiographic and clinical findings to determine the need for revision


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 24 - 24
1 Apr 2022
Partridge T Osborne S Marsh M Holland J
Full Access

We present a consecutive case cohort of the first 100 Birmingham Hip Resurfacing (BHR)'s in 90 patients with a minimum follow up of 20 years. All procedures were performed by a single surgeon having commenced the study in 1998. The original cohort included 68 males with 75 hips (7 bilateral) and 22 females with 25 hips (3 bilateral). The mean age at index procedure was 52. Patients were recalled to review in clinic as per Medicines and Healthcare products Regulatory Agency guidelines with x-rays, metal ions and Harris Hip Scores recorded. After a minimum of 20 year follow-up review the known overall revision rate is 11%. 11 have died and 7 have been lost to review. In males the known revision rate is 4/75 (5%), 3 of which were due to early fractures and 1 revision for infection at 5 years. The known revision rate in females is 7/25 (28%) of which 6 were due to adverse reactions to metal debris; 3 at 7–8 yrs, 1 at 15 yrs, 2 at 18 years, and 1 at 2 months for avascular necrosis. The mean 20 year metal ions results were cobalt 36.6 nmol/l (range 7.4–232.1) and chromium 32.1 nmol/l (range 6–120.8). The mean Harris hip score was 88.5 (range 38.6–99.8). This case series with 20 years follow-up demonstrates excellent long term survival of the BHRs further to registry BHR data and similar to THR for same age recipients. Applying today's strict criteria for patient selection would likely improve survival rate further. BHR has not demonstrated the catastrophic revision rates associated with some metal-on-metal resurfacing and remains a safe option for those who meet the criteria


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_18 | Pages 6 - 6
1 Nov 2016
Lim J Foster N Ridley D Johnston L Clift B
Full Access

The use of Birmingham hip resurfacing (BHR) remains controversial due to the increased revision rate in female patients. We compared the outcomes of BHR in female patients to an age matched total hip arthroplasty(THA) cohort. We reviewed the pain, function and total Harris Hip Scores(HHS), and Kaplan-Meir survivorship for BHR and THA cohorts from a prospective regional arthroplasty database. There were 234 patients in each cohort, with mean age of 51 years. The BHR cohort had significantly better function and total HHS at all points of the 5-year study, but not for the post-operative pain score. The 5-year revision rate for the BHR cohort was significantly higher than the THA cohort (6.8% vs 3.4%, p=0.001). The main reason for revision in the BHR cohort was aseptic loosening (n=8), followed by metallosis (n=3). The 5-year Kaplan-Meier survivorship was 92.6% (95% CI±1.7%) and 96.4% (95% CI±1.3%) for the BHR and THA cohort (p=0.001). BHR can give significantly better functional outcomes than THA. The vast majority of female patients were happy with BHR and did not need further surgery at the 5-year stage. This is somewhat at odds with the recent reputation of the procedure. The 10-year result of the same cohort is warranted to provide further data. Our study is not a recommendation to still offer BHR to female patients, but rather to inject a note of realism into the debate. There are implications for future implant development in that these results do validate resurfacing as a functionally valuable option for active patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 5 - 5
17 Nov 2023
Mahajan U Mehta S Kotecha A
Full Access

Abstract. Introduction. In general the life expectancy of population is improving. This is causing to increase case load of peri-prosthesis fractures after joint replacements. We present our results of peri-prosthesis fracture around hip managed by revision arthroplasty. Methods. A retrospective analysis of 24 consecutive patients of periprosthetic hip fracture treated with a revision arthroplasty at Major Trauma Centre between February 2021 and January 2022. Results. 12 male and 12 female patients, average age 78 years. 3 fractures around BHR prosthesis, 2 type A, 15 type B and 3 of type C (Vancouver). The surgery was done in an average 6 days after injury (range 1–14). 6 patients died in follow up, 1 patient contracted infection, 2 developed LLD and 1 patient had multiple dislocations. 6 patients had revision using endo-prosthesis. Advanced age with peri-prosthesis fracture has increased risk of mortality (average age 84.5 years). Conclusion. Endo-prosthesis replacement had higher risk of dislocation, infection and mortality. Overall patients do well after a revision arthroplasty for periprosthetic hip fracture. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 14 - 14
1 Dec 2014
Kakkar R Ramaskandhan J Bettinson K Muthumayandi K Kometa S Lingard E Holland JP
Full Access

Birmingham Metal-on-metal total hip resurfacing (BHR) is a bone-conserving option for patients with advanced articular damage. While the outcomes of Total Hip Replacement (THR) are well documented, there is a paucity of literature comparing the patient reported outcomes of BHR versus THR. This study aims to compare the patient reported outcomes for an impact on quality of life between patients who had a BHR vs. THR after correcting for selection bias. Patients who underwent a BHR or THR between July 2003 and December 2006 were included. Patient questionnaires included demographic details, co-morbidities, WOMAC, SF-36 Scores. In addition, a 4 point Likert scale was used to measure satisfaction post-operatively. The above data was collected pre-operatively and at 1, 2, 3 and 5 years post-operatively. Data was analysed with SPSS (version 19) software package. All analysis was adjusted for Age, gender, Co-morbidity and pre-operative score by using Multivariate regression analysis using a General Liner Model to rule out the effect of these predictors on outcomes between groups. 337 patients were included (205 for THR and 132 for BHR). BHR patients were younger than THR patients (49 vs. 67 years, p<0.01), were more likely to be male (68% vs. 42% of THR, p<0.01), reported fewer co-morbidities (1.06 vs. 1.59, p<0.01). BHR patients reported better WOMAC pain and function scores at 5 years (p<0.05). For SF-36 scores, BHR patients reported higher scores for all 8 domains at 1 year and 5 year follow up (p<0.05). BHR patients reported higher satisfaction than THR group for return to Activities of Daily Living and Recreational activities at 1 and 5 years (p<0.05). After correction for patient variability, BHR patients reported better improvement in pain and function and enjoyed a better quality of life in relation to return to ADL and recreational activities over to 5 years post-surgery


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 33 - 33
2 May 2024
Dickenson E Griffin J Wall P McBryde C
Full Access

The 22 year survivorship of metal on metal hip resurfacing arthroplasty (RSA) is reported to be 94.3% with expert surgeons, in males with head sizes greater than 48mm. The 2023 National Joint Registry (NJR) report estimates survivorship of all RSA at 19 years to be 85%. This estimate includes all designs, head sizes and females. Our aim was to estimate the survivorship of RSA currently available for implantation (males only, head size >48mm, MatOrtho Adept or Smith and Nephew Birmingham Hip Resurfacing (BHR)) in those under 55 years, performed by all surgeons, compared to conventional THR. We performed a retrospective analysis of the NJR. We included all males under 55 years who had undergone BHR or Adept RSA with head size greater than 48mm. Propensity score matching was used to produce two comparable groups of patients for RSA or conventional THR. We matched in a 3:1 ratio (THR:RSA) using sex, ASA, BMI group, age at primary procedure, surgeon volume, diagnosis and surgeon grade as covariates. The primary analysis was survivorship at 18 years. Time-to-revision was assessed using Kaplan-Meier curves. Cox's proportional hazard models were used to investigate between group differences. 4839 RSA were available for analysis. After matching the RSA and THR groups were well balanced in terms of covariates. Survivorship at 18 years was 93.7% (95% CI 89.9,96.2) in the RSA group and 93.9% (90.5,96.0) in the THR group. Despite these similar estimates the adjusted hazard ratio was 1.40 (95% CI 1.18, 1.67 p<0.001) in favour of THR. Survivorship of the currently available RSA in males under 55 was 93.7% at 18 years, however THR survivorship was superior to RSA. These results, generalisable to UK practice, should be set against perceived benefits in functional status offered in RSA when counselling patients


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 38 - 38
1 Dec 2022
Sheridan G Hanlon M Welch-Phillips A Spratt K Hagan R O'Byrne J Kenny P Kurmis A Masri B Garbuz D Hurson C
Full Access

Hip resurfacing may be a useful surgical procedure when patient selection is correct and only implants with superior performance are used. In order to establish a body of evidence in relation to hip resurfacing, pseudotumour formation and its genetic predisposition, we performed a case-control study investigating the role of HLA genotype in the development of pseudotumour around MoM hip resurfacings. All metal-on-metal (MoM) hip resurfacings performed in the history of the institution were assessed. A total of 392 hip resurfacings were performed by 12 surgeons between February 1st 2005 and October 31st 2007. In all cases, pseudotumour was confirmed in the preoperative setting on Metal Artefact Reduction Sequencing (MARS) MRI. Controls were matched by implant (ASR or BHR) and absence of pseudotumour was confirmed on MRI. Blood samples from all cases and controls underwent genetic analysis using Next Generation Sequencing (NGS) assessing for the following alleles of 11 HLA loci (A, B, C, DRB1, DRB3/4/5, DQA1, DQB1, DPB1, DPA1). Statistical significance was determined using a Fisher's exact test or Chi-Squared test given the small sample size to quantify the clinical association between HLA genotype and the need for revision surgery due to pseudotumour. Both groups were matched for implant type (55% ASR, 45% BHR in both the case and control groups). According to the ALVAL histological classification described by Kurmis et al., the majority of cases (63%, n=10) were found to have group 2 histological findings. Four cases (25%) had group 3 histological findings and 2 (12%) patients had group 4 findings. Of the 11 HLA loci analysed, 2 were significantly associated with a higher risk of pseudotumour formation (DQB1*05:03:01 and DRB1*14:54:01) and 4 were noted to be protective against pseudotumour formation (DQA1*03:01:01, DRB1*04:04:01, C*01:02:01, B*27:05:02). These findings further develop the knowledge base around specific HLA genotypes and their role in the development of pseudotumour formation in MoM hip resurfacing. Specifically, the two alleles at higher risk of pseudotumour formation (DQB1*05:03:01 and DRB1*14:54:01) in MoM hip resurfacing should be noted, particularly as patient-specific genotype-dependent surgical treatments continue to develop in the future


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 337 - 337
1 May 2009
Ulrich C Lill M Fitzgerald D Templeton D Earnshaw S
Full Access

The Birmingham Hip Resurfacing (BHR) has become increasingly popular for young active patients with severe OA of the hip. Although it has been in use in the UK since 1991, none were performed in NZ until late 2004. We have reviewed our initial results & have compared them to a similar group of patients who received conventional total hip replacement (THR) with ceramic-on-ceramic bearings. All patients aged 65 years or less undergoing either BHR or ceramic-on-ceramic THR under the care of the 2 senior authors (DRT & SAE) between October 2003 & July 2006 were included in the study. Patients were assessed pre- & post-operatively clinically & by questionnaires including the Harris Hip (HH) score & modified University of California Los Angeles (UCLA) activity score. Patients were also asked about activity levels prior to their hip symptoms. 59 BHR (38 resurfacings & 21 modular) and 55 THR were performed. 3 BHR & 1 THR patients were not able to be reviewed giving 97% follow up at 6–39 months. 3 patients had minor superficial wound infections (1 BHR & 2 THR). 1 BHR dislocated in recovery but has since been stable. 1 BHR has recently been revised for deep infection. We have had no peri-prosthetic fractures. BHR patients were slightly younger & were more active than the THR patients both pre- and post-operatively. Both group’s HH & UCLA scores improved significantly with surgery. BHR patients had a slightly greater improvement in HH score, but this failed to reach significance. When patients with single joint disease were considered, THR patients remained less active than prior to their hip symptoms whereas the BHR group’s activity scores matched their pre-disease level. All but 2 BHR patients and all of the THR patients were satisfied with their result at the time of review. Our initial experience with the BHR has been positive. Although we have achieved excellent results with both the BHR and with ceramic-on-ceramic THR, the results of the BHR do seem superior in relation to post operative activity levels. The two groups were, however, non-randomised and did differ with respect to age & activity levels, so these comparative results should be interpreted with some caution


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 36 - 36
1 Jan 2018
Ford M Hellman M Kazarian G Clohisy J Nunley R Barrack R
Full Access

Surface replacement arthroplasty (SRA) has been proposed as a viable option for the treatment of osteoarthritis in young, active patients. Positive results of the Birmingham Hip Resurfacing (BHR) in select patient groups have been described in international series and registry data. We report 5–10 year U.S. follow-up for the BHR at our high volume institution. 314 patients (361 hips) between 2006–2011 underwent BHR at our institution and agreed to participate in research. Demographic features, modified Harris Hip Score, UCLA Activity Score, and satisfaction were recorded for patients with minimum 5-year follow-up (90%). Radiographs were evaluated for implant position and “at risk” signs. Complications, reoperations, and revisions were investigated. Mean modified Harris Hip and UCLA scores significantly improved postoperatively to scores of 89.96 and 7.90 (p < 0.001), respectively. Kaplan-Meier estimated survival for all-cause revision was 96.7% [95% CI 94.7 – 98.7%] at 5 years and 91.5% [95% CI 85.3 – 97.6%] at 10 years. Estimated survival for aseptic revision in males less than 60 years old with a primary diagnosis of osteoarthritis was 99.5% [95% CI 98.7 – 100%] at 5 years and 98.8% [95% CI 97.0 – 100%] at 10 years. 14 patients required revision, including 5 revisions for adverse local tissue reaction. Our study demonstrated excellent survivorship and clinical outcomes at 5–10 year follow up for the BHR. These results mirror other series and registry data published outside of the United States. Continued long-term follow-up and additional studies are necessary to validate the long-term safety and outcomes of the BHR, especially in young active arthroplasty patients


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 390 - 390
1 Jul 2010
Langton D Sprowson A Jameson S Joyce T Reed M Partington P Carluke I Nargol A
Full Access

Background: There are no large comparative metal ion studies of commercially available hip resurfacing devices which have taken into account the effects of femoral size and cup inclination and anteversion. Patients and methods: Metal ion analysis is carried out routinely at our independent centre. We present the metal ion results of 95 unilateral ASR patients and 70 unilateral BHR patients. For all patients, acetabular cup orientation was assessed using EBRA software. Patients with other metallic implants and those within 12 months of surgery were excluded. Results: Whole blood/serum chromium (Cr) and cobalt (Co) concentrations were inversely related to femoral component size in both the ASR and BHR group (p< 0.05). Cr and Co levels were only seen to increase in the BHR group when the cup was implanted with an inclination greater than 55°. A significant relationship was identifed between the anteversion of the BHR cup and Cr and Co (p< 0.05 for Co, Spearman Rank correlation), with an increase in ions observed at anteversion angles > 17°. Cr and Co were more strongly influenced by cup position in the case of the ASR, with an increase in metal ions observed at inclinations greater than 45° and anteversion angles of < 10° and > 20°. Discussion: The increased tolerance of the BHR cup to inclinations between 45–55° is likely due to the larger BHR cup providing greater protection against edge loading. When the cohort was divided by gender, the median Cr concentrations of the male ASR patients were significantly lower than those of the BHR males (p< 0.001). This suggests that in larger components positioned at more satisfactory angles of inclination and anteversion, the lower clearance of the ASR proves more significant than the extra coverage provided by the BHR cup. The BHR appears to be more sensitive to changes in anteversion than inclination


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 548 - 548
1 Nov 2011
Baker R Pollard T Eastaugh-Waring S Bannister G
Full Access

Introduction: We compared the eight- to ten-year clinical and radiological results of the metal-on-metal Birmingham hip resurfacing (BHR) with a hybrid total hip arthroplasty (HYBRID) in two groups of 54 hips, previously matched for gender, age, body mass index and activity level. Method: Patients were followed up in outpatients and function assessed by using the Oxford Hip Score, UCLA activity score and Euroqol score. Radiographs were assessed for osteolysis and wear. BHR were also assessed for the presence of a pedestal sign around the femoral component. Results: The mean follow up of the BHR group was 9 years (8.17 to 10.33) and for hybrids 10 (7.53 to 14.5). Four patients had died in the hybrid group and one in the BHR. Four were lost to follow up in each group. The revision rate in the BHR group was 9.25% verses 18% in the Hybrid, a further eight patients in the hybrid group have evidence of wear and osteolysis and are intended for revision (p=0.008). One patient in the BHR group was explored for late onset sciatic nerve palsy. All patients in the hybrid group had evidence of polyethylene wear, mean 1.24mm (0.06–3.03). 90% of the BHR group had evidence of a pedestal sign. Satisfactory function was shown in both groups. There was no significant difference between groups with respect to the OHS but the UCLA score was superior in the BHR group (p=0.008). There was no significant difference for Euroqol visual analogue score. 56% of hybrids were delighted with their hip replacement verses 65% of BHR patients. Discussion: After ten years the hip resurfacing patients were still more active and had a lower revision burden than the hybrid hip replacements. Both groups showed worrying radiological evidence of change with long-term follow-up


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 388 - 388
1 Dec 2013
Latham J Cook R Bolland B Wakefield A Culliford D Tilley C
Full Access

Introduction. Metal on metal hip arthroplasty continues to be controversial. Emerging evidence suggests that there are multiple modes of failure, and that the results of revision surgery are influenced by host and implant factors. Methods. This study compares a single surgeon series of hip resurfacings (Birmingham Hip Resurfacing {BHR}) and large diameter metal on metal total hip replacements (LDMOMTHR). Primary outcome measures included survival rates, failure secondary to histologically identified Adverse Reaction to Metal Debris (ARMD), and patient reported outcome measures (Oxford Hip Score {OHS}) following revision. Between 1999 and 2005, 458 BHR and 175 LDMOMTHR were performed. At latest review 43 BHR's (9.4%) and 28 LDMOMTHR's (14%) have been revised. Results. Failure secondary to ARMD was significantly greater in LDMOMTHR compared to BHR failures (89% and 16% respectively). Histology demonstrated a higher Aseptic Lymphocytic Vascular and Associated Lesions (ALVAL) score in the LDMOMTHR failures than the BHR failures (8.6 LDMOMTHR, 6.3 BHR). Patient reported outcomes were better following revision for failed BHR compared to LDMOMTHR. There was no difference between the revision cohorts for cup inclination, metal ion levels and gender. Failure of the BHR has predominantly been due to those causes unique to resurfacing such as avascular necrosis and fracture. In our series, aggressive ALVAL was unusual and clinical outcome following revision was superior compared to LDMOMTHR failures. The likely mechanisms that are responsible for the differences in outcome and the clinical implications will be discussed


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 21 - 21
1 Jul 2020
Nandra R Ahmed U Berryman F Brash L Dunlop D Matharu G
Full Access

Introduction. Many worldwide regulatory authorities recommend regular surveillance of metal-on-metal hip arthroplasty patients given high failure rates. However concerns have been raised about whether such regular surveillance, which includes asymptomatic patients, is evidence-based and cost-effective. We determined: (1) the cost of implementing the 2015 MHRA surveillance in “at-risk” Birmingham Hip Resurfacing (BHR) patients, and (2) how many asymptomatic hips with adverse reactions to metal debris (ARMD) would have been missed if patients were not recalled. Methods. All BHR patients subject to the 2015 MHRA recall (all females, and males with head sizes 46mm or below, regardless of symptoms) at one specialist centre were invited for review (707 hips). All patients were investigated (Oxford Hip Score, radiographs, blood metal ions, and targeted cross-sectional imaging) and managed accordingly. Surveillance costs were calculated using finance department data, as was the number needed to treat (NNT) to avoid missing one case of asymptomatic ARMD. Results. The overall institutional surveillance cost to investigate all patients once was £105,922 (range £148 to £258 per patient). The most expensive aspects of surveillance were radiographs (£39,598), advanced nurse practitioner assistance (£23,618), cross-sectional imaging (£14,828), and blood metal ions (£14,825). 31 hips had imaging evidence of ARMD (12 revised, with 19 under surveillance). Seven hips were asymptomatic, however all revisions were symptomatic. The NNT to avoid missing one case of asymptomatic ARMD (on imaging and/or requiring revision) was 101 patients, equating to a screening cost of £18,041 to avoid one case of asymptomatic ARMD. Conclusions. Implementing MHRA surveillance for “at-risk” BHR patients was extremely costly, both financially and logistically. As the risk of asymptomatic ARMD was low, our data suggests the 2015 MHRA surveillance is not cost-effective. We therefore have concerns about the increasingly intensive surveillance recommended in the 2017 MHRA guidance for all metal-on-metal hip arthroplasty patients