We investigated factors associated with postoperative lipiduria and hypoxemia in patients undergoing surgery for orthopedic fractures. We enrolled patients who presented to our emergency department due to traumatic fractures between 2016 and 2017. We collected urine samples within 24 hours after the patients had undergone surgery to determine the presence of lipiduria. Hypoxemia was defined as an SpO2 <95% determined with a pulse oximeter during the hospitalization. Patients’
Introduction. Distraction histogenesis is utilised for cosmetic reasons in patients with constitutional short stature, achondroplasias, or height dysphoria. One of the considerations of patients and surgeons alike, is the preservation of aesthetically acceptable body proportions after the lengthening i.e which segment of the lower limb to lengthen and by how much, in order to preserve the patient's proportions within -or as close as possible to- the normal range of human body proportions. Sound
Aim. This study aims to define the normal postoperative presepsin kinetics in patients undergoing primary cementless total hip replacement (THR). Methods. Patients undergoing primary cementless THR at our Institute were recruited. At enrollment
Recently a great amount of research has been conducted into fatigability of paraspinal muscles in relation to Lower Back Pain (LBP). Additionally relationships have been observed between a general level of “fitness” and LBP. This research project aimed to evaluate the influence of aerobic fitness and health on lower back muscle function as measured by Electromyographic (EMG) spectral parameters. Participants undertake a series of psychometric tests,
As for the number of patients who requires total knee arthroplasty (TKA), Asian-Pacific countries will be the most important market. However, due to the paucity of
Introduction. Hip arthroplasty is considered common to patients aged 65 and over however, both Jennings, et al., (2012) and Bergmann (2016) found THA patients are substantially younger with more patients expecting to return to preoperative activity levels. With heavier, younger, and often more active patients, devices must be able to support a more demanding loading-regime to meet patient expectations. McClung (2000) demonstrated that obese patients can display lower wear-rates with UHMWPE bearing resulting from post-operative, self-induced reduced ambulatory movement, thus questioning if obese kinematics and loading are indeed the worst-case. Current loading patterns used to test hip implants are governed by ISO 14242-1 (2014). This study aimed to characterize a heavy and active population (referred to as HA) and investigate how the gait profile may differ to the current ISO profile. Method. A comprehensive
Designs of medical devices are tested for their mechanical behaviour, ability to transfer the load that is normally bore by the healthy tissue, and prove of the resistance to fatigue. The virtual testing in silico is widely accepted technique based on three sets of input data – geometry is normally obtained from CT or MRI scan as well as the tissue density that is translated into mechanical properties of the tissue. The virtual behaviour of the system is controlled by set of constrains accordingly while the third set of data consist of the load that system normally transfers through the load-bearing tissue. The magnitude and character of the load is highly dependent on the physical activity, external loads, physical condition of the subject and its specific factors such as gender, health condition, etc. Most of the published simulations use estimated simplified loads, which barely simulate the real behaviour of the system. The evaluation of the spinal load published some years back estimated a normal (N) and shear force (S) accompanied by the flexing moment (M). Due to lack of experimental possibility we used these data to test the biomechanical response of the lumbar segment with isotropic material models of all tissues. Then we investigated the possibility to evaluate muscular forces and their recruitment. It is a complex task and even today it is not possible to measure directly in vivo all muscular forces contributing to the movement. The musculo-skeletal system is a statically indeterminate system. The forces can be solved by means of computational modelling based on the measured trajectories of the body motion and additional optimization functions combined with static equations. The trajectories were recorded by the fast camera system in our motion laboratory and consequently exported into an open simulation software that uses a generic skeleton with around two hundreds muscle fascicles. The skeleton was scaled to correspond to our subject's
Introduction. The purpose of this study was to experimentally evaluate impingement and dislocation of total hip replacements while performing dynamic movements under physiological-like conditions. Therefore, a hardware-in-the-loop setup has been developed, in which a physical hip prosthesis actuated by an industrial robot interacts with an in situ-like environment mimicked by a musculoskeletal multibody simulation-model of the lower extremity. Methods. The multibody model of the musculoskeletal system comprised rigid bone segments of the lower right extremity, which were mutually linked by ideal joints, and a trunk. All bone geometries were reconstructed from a computed tomography set preserving anatomical landmarks. Inertia properties were identified based on
Introduction & aims. Different racial groups show variations in femoral morphometry. Femoral anteroposterior measurement and mediolateral measurement are key variables in designing femoral implant for TKR. Their aspect ratio determines the shape and mediolateral sizing for the proper patellofemoral tracking and uniform stress distribution over the resected distal femoral surface. Method. We reviewed the current literature in December 2013 in common medical databases including the Cochrane Library, PubMed and Medline. Keywords included combinations of: Anthropometry, Knee, Arthroplasty, Femur, Morphometry, Geometry. We selected papers including femoral morphometric data collected from populations of different ethnic origins. Papers covered populations in the USA, China, Germany, Thailand, Korea, India, Japan and Malaysia. Results. We have analysed femoral morphometry variables among different ethnic groups from the available data. Gross size of the resected femur can be defined in terms of antero-posterior (AP) and medio-lateral (ML) dimensions, an in the aspect ratio of femoral medio-lateral to femoral antero-posterior dimensions (fML/fAP). The Korean population showed the least value of fAP among all the groups, followed by Thai, Japanese, Indian, Malaysian and Chinese showing the increasing order among the sub-groups of Asian Population. American population shows the next higher fAP measurements from Asian population. German follows, and Arab quantify the largest value of this femoral anthropometric variable. fML varies by huge difference among male and female data in all populations. Thai, Indian, Malaysian, Arab, Japanese, Korean, German, Chinese and American; this sequence is the increasing order of fML. More trapezoid-shaped and narrower ML, this variation in female group leads to over-hang the implant for a given fAP. Generally, the aspect ratios are measured higher in these smaller female knees, and lower in larger male knees. Conclusions.
Introduction. Precise implant matching with a resected bony surface is a crucial issue to ensure a successful total knee arthroplasty (TKA). Extremely undersized or oversized components should be avoided. Therefore, we should measure the exact
Purpose: The purpose of the study is to measure the resected surface of femur of the Korean patients during total knee arthroplasty surgery and to compare these measurements with the dimensions of femoral implants in current use. Materials and Methods: Morphometric data (7 parameters) were obtained in 500 cases of resected femur of the Korean patients who underwent total knee arthroplasties, and these data were compared with four current implants designs. Results: The range of medial-lateral width at the given implant varies widely. The anterior width of the resected femur at the condyle is smaller than the widths of the most implants, creating an overhang. The medial-lateral width of the condyle at the level of transepicondylar line is wider than most of the present implants. However the widths of the resected posterior condyles were narrower at anterior-posterior alignment, causing overhang at the posterior condyles. We felt this will cause anterior tensioning at flexion and reduce the ability to flex further. Conclusion: The shape of the femur in Korean knee is different from that of current TKR implants in use, which are based on the
Most studies on LBP have focused on adults although many investigations have shown that the roots of LBP lie in adolescence. Several mechanical, physical and behavioral factors have associated with non-specific LBP in adolescents. To our knowledge no previous study has investigated using advanced statistics all previously reported parameters together with psychological and psychosocial factors on LBP in adolescents aged 15–19 years. 688 students aged 16± 1 years from 5 randomly selected high schools participated in this multifactorial study and completed a questionnaire containing questions on daily activity, backpacks carrying, psychological and psychosocial behavior.
The purpose was to investigate back pain and disability and their relationship to vertebral changes in patients with untreated Scheuermann's. Overall, 136 patients who had attended the outpatient clinics between 1950 and 1990 for Scheuermann's were contacted, 49 of them (12 females, 37 males) responded. There was no difference in the baseline data between responders and non-responders. From radiographs, th-kyphosis, l-lordosis, and scoliosis were measured. The number of affected vertebrae and the degree of wedging were registered.
Study design: Prospective multifactorial study on low back pain (LBP) in adolescents. Background data: Most studies on LBP have focused on adults although may investigations have shown that the roots of LBP lie in adolescence. Several mechanical, physical and behavioral factors have associated with non-specific LBP in adolescents. To our knowledge no previous study has investigated using advanced statistics all previously reported parameters together with psychological and psychosocial factors on LBP in adolescents aged 15–19 years. Material and Methods: 688 students aged 16± 1 years from 5 randomly selected high schools participated in this study and completed a questionnaire containing questions on daily activity, backpacks carrying, psychological and psychosocial behavior.
Introduction: The foot is a very complex structure acting as the platform for all gait patterns. At present, little is known about the exact biomechanics of the foot due to the difficulties in modeling all of the components of the foot accurately. This has made it virtually impossible to develop a complete understanding of the aetiology of many diseases of the foot including hallux rigidus. We hypothesize that sagittal plane incongruency of the rotation of the 1. st. Metatarsophalangeal Joint (MTPJ), or an increase in the tension of the intrinsic plantar flexors is responsible for the development of hallux rigidus. Materials &
Methods: Ground reaction forces and kinematic data from gait analysis together with
The aim of this investigation was to compare risk of infection in both cemented and uncemented hemiarthroplasty (HA) as well as in total hip arthroplasty (THA) following femoral neck fracture. Data collection was performed using the German Arthroplasty Registry (EPRD). In HA and THA following femoral neck fracture, fixation method was divided into cemented and uncemented prostheses and paired according to age, sex, BMI, and the Elixhauser Comorbidity Index using Mahalanobis distance matching.Aims
Methods
The incidence of acetabular fractures within the UK is about 3 in 100,000 of the population per year. Since Letournel and Judet first proposed that operative reduction and rigid internal fixation of displaced fractures will likely lead to better outcome, operative management of such fractures has become standard management in major trauma centres. Long term outcome results following acetabular surgery have been reported sparingly. Two hundred and fifty-seven displaced acetabular fractures underwent an open reduction and internal fixation at St. George’s Pelvic Unit between 1992 and 1997. All surgery was performed by a single surgeon. 161 patients were followed up prospectively for a minimum of 10 years. Those lost to follow up were excluded.
Purpose. The majority (73%) of orthopaedic surgeons in Canada prefer using semitendinosus-gracilis (STG) autograft for ACL reconstruction. However, there is large variation in tendon size between individuals which makes pre-operative estimation of graft size unpredictable. Inadequate graft size may require an alternative source of graft tissue that should be planned prior to surgery. The purpose of this study is to determine if clinical
Purpose: There is no data concerning morphological dimensions of distal femur(DF), proximal tibia(PT) and thickness of patella(TP) in Indian population and our objective was to analyse the
There is no data concerning morphological dimensions of distal femur, proximal tibia and patella in Indian population. The objective was to analyse the