header advert
Results 1 - 100 of 179
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 36 - 36
10 May 2024
Bolam SM Matheson N Douglas M Anderson K Weggerty S Londahl M Gwynne-Jones D Navarre P
Full Access

Introduction

The Te Whatu Ora Southern catchment area covers the largest geographical region in New Zealand (over 62,000 km2) creating logistical challenges in providing timely access to emergency neck of femur (NOF) fracture surgery. Current Australian and New Zealand guidelines recommend that NoF surgery be performed within 48 hours of presentation. The purpose of this study was to compare the outcomes for patients with NoF fractures who present directly to a referral hospital (Southland Hospital) compared to those are transferred from rural peripheral centres.

Methods

A retrospective cohort study identified 79 patients with NoF who were transferred from rural peripheral centres to a referral hospital for operative management between January 2011 to December 2020. This cohort was matched 1:1 by age and sex to patients with NoF who presently directly to the referral hospital over the same period. The primary outcome was to compare time to surgery between the groups and secondary outcomes were to compare length of hospital stay, complication rates and mortality rates at 30-days and 1-year.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_3 | Pages 1 - 1
23 Jan 2024
Stanley AL Jones TJ Dasic D Kakarla S Kolli S Shanbhag S McCarthy MJH
Full Access

Aims

Traumatic central cord syndrome (CCS) typically follows a hyperextension injury and results in a motor impairment affecting the upper limbs more than the lower limbs, with occasional sensory impairment and urinary retention seen. Current evidence on mortality and long-term outcomes is limited. The primary aim of this study is to assess the five-year mortality of CCS, and to determine any difference in mortality between management groups or age.

Patients and Methods

Patients ≥18 years with traumatic CCS between January 2012 and December 2017 in Wales were identified. Patient demographics and injury, management and outcome data was collected. Statistical analysis was performed to assess mortality and between group differences.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_3 | Pages 11 - 11
23 Jan 2024
Raj S Magan A Jones SA
Full Access

Dual mobility (DM) is an established bearing option in Total Hip Arthroplasty (THA). The traditional mono-block DM designs have limited ability for additional fixation, whereas the modular DM designs allow additional screw fixation but limit internal diameter and have the potential to generate metal debris. We report the early results of a CoCrMo alloy mono-block implant manufactured by additive technology with a highly porous ingrowth surface to enhance primary fixation and osseointegration.

Prospective follow-up of the DuplexTM implant first inserted in March 2016 enrolled into Beyond Compliance (BC). Primary outcome measure was all-cause revision and secondary outcomes dislocation, peri-prosthetic fracture (PPF) and Oxford Hip Score (OHS). Patients were risk stratified and all considered to be high risk for instability. Complications were identified via hospital records, clinical coding linkage using national database and via BC website.

159 implants in 154 patients with a mean age 74.0 years and a maximum F/U of 7 years. Survivorship for all-cause revision 99.4% (95% CI 96.2–99.8). One femoral only revision. Mean gain in OHS 27.4. Dislocation rate 0.6% with a single event. Patients with a cemented Polished taper stem (PTS) had a Type B PPF rate of 2.1% requiring revision/fixation. Compared to conventional THA this cohort was significantly older (74.0 vs 68.3 years), more co-morbidity (ASA 3 46.5% vs 14.4%) and more non-OA indications (32.4% vs 8.5%). Every patient had at least one risk factor for falling and >50% of cohort had 4 or more risk factors using NICE tool.

We believe our results demonstrate that risk stratification successfully aids implant selection to prevent dislocation in high-risk patients. This novel design has provided excellent early results in a challenging cohort where individuals are very different to the “average” THA patient. NJR data on DM has reported an increase in revision for PPF. A “perfect storm” maybe created using DM in high-risk falls risk population. This re-enforces the need to consider all patient and implant factors when deciding bearing selection.


Introduction

Achilles Tendon Rupture (ATR) is a prevalent injury in Western society. Much of the recent research has focused on measuring surgical methods and strength regained, rather than practical measures such as Return to Sport (RTS). A large systematic review was published in 2016 setting a benchmark RTS as 80%. The aim of this systematic review was to provide an up-to-date RTS following ATR.

Methods

PubMed and SPORTdiscuss databases were used to search for eligible studies published since 2017 that focused on closed Achilles tendon ruptures with clear definitions of return to sport and a minimum length of follow-up. The Newcastle-Ottawa grading tool was used to assess risk of bias in all included studies.


Bone & Joint Open
Vol. 4, Issue 3 | Pages 146 - 157
7 Mar 2023
Camilleri-Brennan J James S McDaid C Adamson J Jones K O'Carroll G Akhter Z Eltayeb M Sharma H

Aims

Chronic osteomyelitis (COM) of the lower limb in adults can be surgically managed by either limb reconstruction or amputation. This scoping review aims to map the outcomes used in studies surgically managing COM in order to aid future development of a core outcome set.

Methods

A total of 11 databases were searched. A subset of studies published between 1 October 2020 and 1 January 2011 from a larger review mapping research on limb reconstruction and limb amputation for the management of lower limb COM were eligible. All outcomes were extracted and recorded verbatim. Outcomes were grouped and categorized as per the revised Williamson and Clarke taxonomy.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 10 - 10
23 Feb 2023
Hardwick-Morris M Twiggs J Miles B Jones E Bruce WJM Walter WL
Full Access

Dislocation is one of the most common complications in total hip arthroplasty (THA) and is primarily driven by bony or prosthetic impingement. The aim of this study was two-fold. First, to develop a simulation that incorporates the functional position of the femur and pelvis and instantaneously determines range of motion (ROM) limits. Second, to assess the number of patients for whom their functional bony alignment escalates impingement risk.

468 patients underwent a preoperative THA planning protocol that included functional x-rays and a lower limb CT scan. The CT scan was segmented and landmarked, and the x-rays were measured for pelvic tilt, femoral rotation, and preoperative leg length discrepancy (LLD). All patients received 3D templating with the same implant combination (Depuy; Corail/Pinnacle). Implants were positioned according to standardised criteria.

Each patient was simulated in a novel ROM simulation that instantaneously calculates bony and prosthetic impingement limits in functional movements. Simulated motions included flexion and standing-external rotation (ER). Each patient's ROM was simulated with their bones oriented in both functional and neutral positions.

13% patients suffered a ROM impingement for functional but not neutral extension-ER. As a result, 48% patients who failed the functional-ER simulation would not be detected without consideration of the functional bony alignment. 16% patients suffered a ROM impingement for functional but not neutral flexion. As a result, 65% patients who failed the flexion simulation would not be detected without consideration of the functional bony alignment.

We have developed a ROM simulation for use with preoperative planning for THA surgery that can solve bony and prosthetic impingement limits instantaneously. The advantage of our ROM simulation over previous simulations is instantaneous impingement detection, not requiring implant geometries to be analysed prior to use, and addressing the functional position of both the femur and pelvis.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 9 - 9
23 Feb 2023
Hardwick-Morris M Twiggs J Miles B Jones E Bruce WJM Walter WL
Full Access

In 2021, Vigdorchik et al. published a large multicentre study validating their simple Hip-Spine Classification for determining patient-specific acetabular component positioning in total hip arthroplasty (THA). The purpose of our study was to apply this Hip-Spine Classification to a sample of Australian patients undergoing THA surgery to determine the local acetabular component positioning requirements. Additionally, we propose a modified algorithm for adjusting cup anteversion requirements.

790 patients who underwent THA surgery between January 2021 and June 2022 were assessed for anterior pelvic plane tilt (APPt) and sacral slope (SS) in standing and relaxed seated positions and categorized according to their spinal stiffness and flatback deformity. Spinal stiffness was measured using pelvic mobility (PM); the ΔSS between standing and relaxed seated. Flatback deformity was defined by APPt <−13° in standing. As in Vigdorchik et al., PM of <10° was considered a stiff spine. For our algorithm, PM of <20° indicated the need for increased cup anteversion. Using this approach, patient-specific cup anteversion is increased by 1° for every degree the patient's PM is <20°.

According to the Vigdorchik simple Hip-Spine classification groups, we found: 73% Group 1A, 19% Group 1B, 5% Group 2A, and 3% Group 2B. Therefore, under this classification, 27% of Australian THA patients would have an elevated risk of dislocation due to spinal deformity and/or stiffness. Under our modified definition, 52% patients would require increased cup anteversion to address spinal stiffness.

The Hip-Spine Classification is a simple algorithm that has been shown to indicate to surgeons when adjustments to acetabular cup anteversion are required to account for spinal stiffness or flatback deformity. We investigated this algorithm in an Australian population of patients undergoing THA and propose a modified approach: increasing cup anteversion by 1° for every degree the patient's PM is <20°.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 31 - 31
23 Feb 2023
Hong N Jones C Hong T
Full Access

Ideberg-Goss type VI/AO F2(4) glenoid fossa fractures are a rare and complex injury. Although some advocate non-operative management, grossly displaced glenoid fossa fractures in the young patient may warrant fixation. Current approaches still describe difficulty with access of the entirety of the glenoid, particularly the postero-superior quadrant.

We present 2 cases of Ideberg-Goss type VI/AO F2(4) glenoid fossa fractures treated with fixation through a novel “Deltoid Takedown” approach, which allows safe access to the whole glenoid with satisfactory clinical results at 5 and 7 years respectively.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 24 - 24
23 Feb 2023
Marinova M Houghton E Seymour H Jones CW
Full Access

Ankle fractures in the elderly are common and have a mortality rate of 12% within the first year. Treatment is challenging due to osteoporotic bone and patient co-morbidities. Many patients struggle with non-weight-bearing (NWB) and presently there is no consensus in the literature regarding optimum management of these injuries.

We hypothesised that early weight-bearing in frail patients, Clinical Frailty scale (CFS) score of 4 or more will reduce morbidity and allow patients to return to their usual place of residence faster without jeopardising clinical outcome.

We conducted a retrospective analysis of 80 patients aged over 65 years managed at Fiona Stanley Hospital for ankle fractures between January 2016 and 2018. Patients were divided into two cohorts: 40 patients managed NWB and 40 who were permitted to weight-bear as tolerated (WBAT). Patients were stratified as fit (CFS 1–3) or frail (CFS 4+). Primary outcomes were one-year mortality, return to primary residence at six weeks and complications. Secondary outcomes included length of acute hospital stay and rehab stay.

For frail patients, those managed NWB stayed in rehab for 19 days longer (p=0.03) and had 28% more complications (p=0.03). By 6 weeks, fewer patients returned to full weight-bearing (p=0.03) and fewer patients had returned home (p=0.01). For fit patients, there were no significant differences in primary outcomes between NWB and WBAT.

Our novel study categorising patients by CSF demonstrates that early mobilisation in frail patients results in improved outcomes. Currently there is no formal treatment protocol for the management of ankle fractures in the elderly, and we hope that our proposed algorithm will assist surgeons at our institution and elsewhere.

Our study suggests that WBAT may benefit frail patients. We propose a protocol to assist in the management of geriatric ankle fracture patients based on clinical frailty scores.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 16 - 16
10 Feb 2023
Gibson A Guest M Taylor T Gwynne Jones D
Full Access

The purpose of this study was to determine whether there have been changes in the complexity of femoral fragility fractures presenting to our Dunedin Orthopaedic Department, New Zealand, over a period of ten years.

Patients over the age of 60 presenting with femoral fragility fractures to Dunedin Hospital in 2009 −10 (335 fractures) were compared with respect to demographic data, incidence rates, fracture classification and treatment details to the period 2018-19 (311 fractures). Pathological and high velocity fractures were excluded.

The gender proportion and average age (83.1 vs 83.0 years) was unchanged. The overall incidence of femoral fractures in people over 60 years in our region fell by 27% (p<0.001). Intracapsular fractures (31 B1 and B2) fell by 29% (p=0.03) and stable trochanteric fractures by 56% (p<0.001). The incidence of unstable trochanteric fractures (31A2 and 31A3) increased by 84.5% from 3.5 to 6.4/10,000 over 60 years (p = 0.04). The proportion of trochanteric fractures treated with an intramedullary (IM) nail increased from 8% to 37% (p <0.001). Fewer intracapsular fractures were treated by internal fixation (p<0.001) and the rate of acute total hip joint replacements increased from 13 to 21% (p=0.07). The incidence of femoral shaft fractures did not change significantly with periprosthetic fractures comprising 70% in both cohorts.

While there has been little difference in the numbers there has been a decrease in the incidence of femoral fragility fractures likely due to the increasing use of bisphosphonates. However, the incidence of unstable trochanteric fractures is increasing. This has led to the increased use of IM nails which are increasingly used for stable fractures as well.

The increasing complexity of femoral fragility fractures is likely to have an impact on implant use, theatre time and cost.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 34 - 34
10 Feb 2023
Farey J Chai Y Xu J Sadeghpour A Marsden-Jones D Baker N Vigdorchik J Walter W
Full Access

Imageless computer navigation systems have the potential to improve acetabular cup position in total hip arthroplasty (THA), thereby reducing the risk of revision surgery. This study aimed to evaluate the accuracy of three alternate registration planes in the supine surgical position generated using imageless navigation for patients undergoing THA via the direct anterior approach (DAA).

Fifty-one participants who underwent a primary THA for osteoarthritis were assessed in the supine position using both optical and inertial sensor imageless navigation systems. Three registration planes were recorded: the anterior pelvic plane (APP) method, the anterior superior iliac spines (ASIS) functional method, and the Table Tilt (TT) functional method. Post-operative acetabular cup position was assessed using CT scans and converted to radiographic inclination and anteversion. Two repeated measures analysis of variance (ANOVA) and Bland-Altman plots were used to assess errors and agreement of the final cup position.

For inclination, the mean absolute error was lower using the TT functional method (2.4°±1.7°) than the ASIS functional method (2.8°±1.7°, ρ = .17), and the ASIS anatomic method (3.7°±2.1, ρ < .001). For anteversion, the mean absolute error was significantly lower for the TT functional method (2.4°±1.8°) than the ASIS functional method (3.9°±3.2°, ρ = .005), and the ASIS anatomic method (9.1°±6.2°, ρ < .001). All measurements were within ± 10° for the TT method, but not the ASIS functional or APP methods.

A functional registration plane is preferable to an anatomic reference plane to measure intra-operative acetabular cup inclination and anteversion accurately. Accuracy may be further improved by registering patient location using their position on the operating table rather than anatomic landmarks, particularly if a tighter target window of ± 5° is desired.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 52 - 52
1 Dec 2022
Hawker G Bohm E Dunbar M Jones CA Ravi B Noseworthy T Woodhouse L Faris P Dick DA Powell J Paul P Marshall D
Full Access

With the rising rates, and associated costs, of total knee arthroplasty (TKA), enhanced clarity regarding patient appropriateness for TKA is warranted. Towards addressing this gap, we elucidated in qualitative research that surgeons and osteoarthritis (OA) patients considered TKA need, readiness/willingness, health status, and expectations of TKA most important in determining patient appropriateness for TKA. The current study evaluated the predictive validity of pre-TKA measures of these appropriateness domains for attainment of a good TKA outcome.

This prospective cohort study recruited knee OA patients aged 30+ years referred for TKA at two hip/knee surgery centers in Alberta, Canada. Those receiving primary, unilateral TKA completed questionnaires pre-TKA assessing TKA need (WOMAC-pain, ICOAP-pain, NRS-pain, KOOS-physical function, Perceived Arthritis Coping Efficacy, prior OA treatment), TKA readiness/willingness (Patient Acceptable Symptom State (PASS), willingness to undergo TKA), health status (PHQ-8, BMI, MSK and non-MSK comorbidities), TKA expectations (HSS KR Expectations survey items) and contextual factors (e.g., age, gender, employment status). One-year post-TKA, we assessed for a ‘good outcome’ (yes/no), defined as improved knee symptoms (OARSI-OMERACT responder criteria) AND overall satisfaction with TKA results. Multiple logistic regression, stepwise variable selection, and best possible subsets regression was used to identify the model with the smallest number of independent variables and greatest discriminant validity for our outcome. Receiver Operating Characteristic (ROC) curves were generated to compare the discriminative ability of each appropriateness domain based on the ‘area under the ROC curve’ (AUC). Multivariable robust Poisson regression was used to assess the relationship of the variables to achievement of a good outcome.

f 1,275 TKA recipients, 1,053 (82.6%) had complete data for analyses (mean age 66.9 years [SD 8.8]; 58.6% female). Mean WOMAC pain and KOOS-PS scores were 11.5/20 (SD 3.5) and 52.8/100 (SD 17.1), respectively. 78.1% (95% CI 75.4–80.5%) achieved a good outcome. Stepwise variable selection identified optimal discrimination was achieved with 13 variables. The three best 13-variable models included measures of TKA need (WOMAC pain, KOOS-PS), readiness/willingness (PASS, TKA willingness), health status (PHQ-8, troublesome hips, contralateral knee, low back), TKA expectations (the importance of improved psychological well-being, ability to go up stairs, kneel, and participate in recreational activities as TKA outcomes), and patient age. Model discrimination was fair for TKA need (AUC 0.68, 95% CI 0.63-0.72), TKA readiness/willingness (AUC 0.61, 95% CI 0.57-0.65), health status (AUC 0.59, 95% CI 0.54-0.63) and TKA expectations (AUC 0.58, 95% CI 0.54-0.62), but the model with all appropriateness variables had good discrimination (AUC 0.72, 95% CI 0.685-0.76). The likelihood of achieving a good outcome was significantly higher for those with greater knee pain, disability, unacceptable knee symptoms, definite willingness to undergo TKA, less depression who considered improved ability to perform recreational activities or climb stairs ‘very important’ TKA outcomes, and lower in those who considered it important that TKA improve psychological wellbeing or ability to kneel.

Beyond surgical need (OA symptoms) and health status, assessment of patients’ readiness and willingness to undergo, and their expectations for, TKA, should be incorporated into assessment of patient appropriateness for surgery.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_2 | Pages 5 - 5
1 Mar 2022
Clutton JM Razii N Chitnis SS Kakar R Morgan-Jones R
Full Access

Introduction

The burden of prosthetic joint infection (PJI) in total knee arthroplasty (TKA) has been rising in line with the number of primary operations performed. Current estimates suggest an infection rate of 1–2.4%. Two-stage revision has traditionally been considered the gold standard of treatment; however, some studies suggest comparable results can be achieved with single-stage procedures. The potential advantages include less time in hospital, a single anaesthetic, reduced costs, and greater patient satisfaction.

Methods

We reviewed data for 72 patients (47 males, 25 females), with a mean age of 71 years (range, 49 to 94), who underwent single-stage revision TKA for confirmed PJI between 2006 and 2016. A standardized debridement protocol was performed with immediate single-stage exchange. All cases were discussed preoperatively at multidisciplinary team (MDT) meetings, which included input from a senior musculoskeletal microbiologist. Patients were not excluded for previous revisions, culture-negative PJI, or the presence of a sinus.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 15 - 15
1 Jan 2022
Tamboowalla KB Gandbhir V Nagai H Wynn-Jones H Talwalker S Kay P
Full Access

Abstract

Background

The COVID-19 pandemic has strongly impacted elective orthopaedic surgery. At our trust, a geographically discrete elective site deals with planned orthopaedic surgery. There was a need to define a green pathway to deliver surgical care safely and efficiently, and tackle mounting waiting lists.

Methods

Records of patients operated at our elective site, between 1st July 2020 and 14th January 2021, under a green pathway, including pre-operative self-isolation, COVID screening and segregating perioperative patients, were reviewed, and analysed retrospectively. Patients who did not attend (DNA) their post-operative follow-up appointments were identified. Finally, regional COVID incidence was compared with that in our centre.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 9 - 9
1 Jun 2021
Greene A Verstraete M Roche C Conditt M Youderian A Parsons M Jones R Flurin P Wright T Zuckerman J
Full Access

INTRODUCTION

Determining proper joint tension in reverse total shoulder arthroplasty (rTSA) can be a challenging task for shoulder surgeons. Often, this is a subjective metric learned by feel during fellowship training with no real quantitative measures of what proper tension encompasses. Tension too high can potentially lead to scapular stress fractures and limitation of range of motion (ROM), whereas tension too low may lead to instability. New technologies that detect joint load intraoperatively create the opportunity to observe rTSA joint reaction forces in a clinical setting for the first time. The purpose of this study was to observe the differences in rTSA loads in cases that utilized two different humeral liner sizes.

METHODS

Ten different surgeons performed a total of 37 rTSA cases with the same implant system. During the procedure, each surgeon reconstructed the rTSA implants to his or her own preferred tension. A wireless load sensing humeral liner trial (VERASENSE for Equinoxe, OrthoSensor, Dania Beach, FL) was used in lieu of a traditional plastic humeral liner trial to provide real-time load data to the operating surgeon during the procedure. Two humeral liner trial sizes were offered in 38mm and 42mm curvatures and were selected each case based on surgeon preference. To ensure consistent measurements between surgeons, a standardized ROM assessment consisting of four dynamic maneuvers (maximum internal to external rotation at 0°, 45°, and 90° of abduction, and a maximum flexion/extension maneuver) and three static maneuvers (arm overhead, across the body, and behind the back) was completed in each case. Deidentified load data in lbf was collected and sorted based on which size liner was selected. Differences in means for minimum and maximum load values for the four dynamic maneuvers and differences in means for the three static maneuvers were calculated using 2-tailed unpaired t-tests.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 6 - 6
1 Feb 2021
Madurawe C Vigdorchik J Lee G Jones T Dennis D Austin M Pierrepont J Huddleston J
Full Access

Introduction

Excessive standing posterior pelvic tilt (PT), lumbar spine stiffness, low pelvic Incidence (PI), and severe sagittal spinal deformity (SSD) have been linked to increased dislocation rates. We aimed to compare the prevalence of these 4 parameters in unstable and stable primary Total Hip Arthroplasty (THA) patients.

Methods

In this retrospective cohort study, 40 patients with instability following primary THA for osteoarthritis were referred for functional analysis. All patients received lateral X-rays in standing and flexed seated positions to assess functional pelvic tilt and lumbar lordosis (LL). Computed tomography scans were used to measure pelvic incidence and acetabular cup orientation. Literature thresholds for “at risk” spinopelvic parameters were standing pelvic tilt ≤ −10°, lumbar flexion (LLstand – LLseated) ≤ 20°, PI ≤ 41°, and sagittal spinal deformity (PI – LLstand mismatch) ≥ 10°. The prevalence of each risk factor in the dislocation cohort was calculated and compared to a previously published cohort of 4042 stable THA patients.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 55 - 55
1 Aug 2020
Goplen C Beaupre L Voaklander D Kang SHH Jones CA
Full Access

Up to 40% of patients are using opioids at the time of joint replacement surgery in the USA despite emerging evidence suggesting opioids are ineffective for chronic non-cancer pain. Our primary objective was to determine if preoperative opioid use among patient awaiting total knee arthroplasty (TKA) was associated with worse patient-reported outcomes (PRO) measures at one-year follow-up when compared to non-opioid users, after adjusting for age, gender, and comorbidities.

The study linked Alberta's Pharmacy Information Network (PIN) data with prospectively collected Alberta Bone and Joint Health Repository administrative data (medical and PRO data) for patients who underwent primary TKA in Alberta from 2013–2015. The PIN contains prescribing information from physician offices and pharmacies across Alberta. Preoperative ‘opioid users’ were defined as having 90-days of consistent opioid use in the 180-days prior TKA, and ‘opioid-exposed’ subjects had recorded opioid prescriptions in the 180-days prior to TKA, but did not meet the definition of an opioid user. Those with no opioid-exposure in the 180-days pre-TKA were deemed a ‘non-opioid user’. We used multiple linear regression to examine how preoperative opioid use (opioid user, opioid-exposed, non-opioid user) impacted Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain and function scores at one year after TKA after adjusting for confounding variables. These included age, sex, preoperative WOMAC scores, comorbidities including depression, diabetes, obesity, stroke, pulmonary disease, renal disease, cardiac disease, liver disease, and overall comorbid burden.

Of the 2182 unique cases identified, 151 (7%) were opioid users, 527 (24%) opioid-exposed and 1504 (69%) non-opioid user. Opioid users were more likely to be prescribed strong opioids (e.g., hydromorphone, oxycodone) compared to with opioid-exposed subjects (p < 0 .001) and had a median morphine equivalent dose of 30.7 mg/day compared with the opioid-exposed group (2.2 mg/day, p < 0 .001) in the 180-days prior to TKA. Opioid users, in the 180-days prior to TKA had an active opioid prescription for a mean duration of 153 days (95CI 149, 157) within the 180-days prior to TKA, compared to 34 days (95CI 32, 37) for opioid-exposed (p < 0 .001). In the parsimonious pain and function models, opioid use, lower preoperative WOMAC score, depression, and obesity were associated with worse one-year pain and function. Patients prescribed preoperative opioids had worse WOMAC scores one-year after TKA respectively when compared to non-opioid users, after adjusting for other factors (opioid user pain score: −9.5, function score: −9.4, opioid exposed pain score: −2.6, function score: −3.6, p < 0 .001 for all). Further, opioid users with a concomitant diagnosis of depression had significantly worse one-year postoperative WOMAC scores when compared to non-depressed non-opioid users (scores −14, p < 0 .001 for both pain and function).

In Alberta, 31% of patients were prescribed opioids within 180-days before TKA, preoperative opioid use was associated with worse one-year postoperative WOMAC pain and function scores relative to non-opioid users. Our results suggest that strategies to reduce preoperative opioid use could improve patient outcomes after TKA, and support the most recent Canadian opioid prescribing guidelines that attempt to minimize opioid use for chronic conditions such as arthritis.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 69 - 69
1 Aug 2020
Boettcher T Kang SHH Beaupre L McLeod R Jones CA
Full Access

Total joint arthroplasty (TJA) is often utilized to improve pain and dysfunction associated with end-stage osteoarthritis. Previous research has suggested that depression may negatively impact patient reported pain and function. The purpose of this study was to determine the effect of pre-operative depressive symptoms, using the Center for Epidemiologic Scale for Depression (CES-D) scale, on patient reported function and pain at one, three and six months following TJA, after controlling for the impact of age, sex, pain, joint replaced, and other comorbidities.

This was a secondary analysis of a prospective cohort of 710 patients aged 40 years and older who underwent elective primary TJA in the Edmonton zone. Participants were recruited pre-operatively and reported socio-demographics, comorbid conditions and medications (including depression medications where appropriate), each participant also completed the Western Ontario McMaster (WOMAC) Osteoarthritis Index and the CES-D scale preoperatively. Participants then completed the WOMAC and CES-D scale again at one, three, and six months postoperatively. Risk-adjusted longitudinal data analysis using a linear mixed regression model was performed, controlling for age, sex, joint replaced, chronic pain, comorbidity, social support and employment status.

THA participants had a mean age of 65.9±10.1 years and included 175 (57%) female while TKA participants had a mean age of 67.9±10.1 years and included 249 (61%) females. ‘Possible’ depressive symptoms (CES-D score 16–19) were identified in 58 (8.1%) participants while ‘probable’ depressive symptoms (CES-D score ≥20) were identified in 68 (9.6%) participants. The mean WOMAC pain and function scores, when analyzed using the linear mixed regression model, demonstrated improvement from baseline at one, three, and six months (p < 0 .001 for both pain and function models as well as over time). However, in the patients with possible and probable depressive symptoms, WOMAC pain scores were 7.6±1.5 and 11.7±1.3 worse respectively than those without depressive symptoms after controlling for age, sex, joint replaced, chronic pain, comorbidities and social support. Similarly, WOMAC function scores in the patients with possible and probable depressive symptoms were 8.8±1.4 and 14.2±1.2 worse respectively than those without depressive symptoms after controlling for age, sex, joint replaced, comorbidities and employment status.

Depressive symptoms negatively affect postoperative pain and function measured using WOMAC scales even after risk adjustment up to six-months post TJA. Screening for depressive symptomology both pre- and postoperatively may provide an opportunity to identify and manage depressive symptoms to improve postoperative pain and function.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 44 - 44
1 Jul 2020
Boettcher T Jones CA Beaupre L Kang SHH McLeod R
Full Access

Total joint arthroplasty (TJA) is often utilized to improve pain and dysfunction associated with end-stage osteoarthritis. Previous research has suggested that depression may negatively impact patient reported pain and function. The purpose of this study was to determine the effect of preoperative depressive symptoms, using the Center for Epidemiologic Scale for Depression (CES-D) scale, on patient reported function and pain at one, three and six months following TJA, after controlling for the impact of age, sex, pain, joint replaced, and other comorbidities.

This was a secondary analysis of a prospective cohort of 710 patients aged 40 years and older who underwent elective primary TJA in the Edmonton zone. Participants were recruited pre-operatively and reported socio-demographics, comorbid conditions and medications (including depression medications where appropriate), each participant also completed the Western Ontario McMaster (WOMAC) Osteoarthritis Index and the CES-D scale preoperatively. Participants then completed the WOMAC and CES-D scale again at one, three, and six months postoperatively. Risk-adjusted longitudinal data analysis using a linear mixed regression model was performed, controlling for age, sex, joint replaced, chronic pain, comorbidity, social support and employment status.

THA participants had a mean age of 65.9±10.1 years and included 175 (57%) female while TKA participants had a mean age of 67.9±10.1 years and included 249 (61%) females. ‘Possible’ depressive symptoms (CES-D score 16–19) were identified in 58 (8.1%) participants while ‘probable’ depressive symptoms (CES-D score ≥20) were identified in 68 (9.6%) participants. The mean WOMAC pain and function scores, when analyzed using the linear mixed regression model, demonstrated improvement from baseline at one, three, and six months (p < 0 .001 for both pain and function models as well as over time). However, in the patients with possible and probable depressive symptoms, WOMAC pain scores were 7.6±1.5 and 11.7±1.3 worse respectively than those without depressive symptoms after controlling for age, sex, joint replaced, chronic pain, comorbidities and social support. Similarly, WOMAC function scores in the patients with possible and probable depressive symptoms were 8.8±1.4 and 14.2±1.2 worse respectively than those without depressive symptoms after controlling for age, sex, joint replaced, comorbidities and employment status.

Depressive symptoms negatively affect postoperative pain and function measured using WOMAC scales even after risk adjustment up to six-months post TJA. Screening for depressive symptomology both pre- and postoperatively may provide an opportunity to identify and manage depressive symptoms to improve postoperative pain and function.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 8 - 8
1 Jul 2020
Goplen C Beaupre L Jones CA Voaklander D Churchill T Kang SHH
Full Access

Up to 40% of patients are using opioids at the time of joint replacement surgery in the USA despite emerging evidence suggesting opioids are ineffective for chronic non-cancer pain. Our primary objective was to determine if preoperative opioid use among patient awaiting total knee arthroplasty (TKA) was associated with worse patient-reported outcomes (PRO) measures at one-year follow-up when compared to non-opioid users, after adjusting for age, gender, and comorbidities.

The study linked Alberta's Pharmacy Information Network (PIN) data with prospectively collected Alberta Bone and Joint Health Repository administrative data (medical and PRO data) for patients who underwent primary TKA in Alberta from 2013–2015. The PIN contains prescribing information from physician offices and pharmacies across Alberta. Preoperative ‘opioid users’ were defined as having 90-days of consistent opioid use in the 180-days prior TKA, and ‘opioid-exposed’ subjects had recorded opioid prescriptions in the 180-days prior to TKA, but did not meet the definition of an opioid user. Those with no opioid-exposure in the 180-days pre-TKA were deemed a ‘non-opioid user’. We used multiple linear regression to examine how preoperative opioid use (opioid user, opioid-exposed, non-opioid user) impacted Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain and function scores at one year after TKA after adjusting for confounding variables. These included age, sex, preoperative WOMAC scores, comorbidities including depression, diabetes, obesity, stroke, pulmonary disease, renal disease, cardiac disease, liver disease, and overall comorbid burden.

Of the 2182 unique cases identified, 151 (7%) were opioid users, 527 (24%) opioid-exposed and 1504 (69%) non-opioid user. Opioid users were more likely to be prescribed strong opioids (e.g., hydromorphone, oxycodone) compared to with opioid-exposed subjects (p < 0 .001) and had a median morphine equivalent dose of 30.7 mg/day compared with the opioid-exposed group (2.2 mg/day, p < 0 .001) in the 180-days prior to TKA. Opioid users, in the 180-days prior to TKA had an active opioid prescription for a mean duration of 153 days (95CI 149, 157) within the 180-days prior to TKA, compared to 34 days (95CI 32, 37) for opioid-exposed (p < 0 .001). In the parsimonious pain and function models, opioid use, lower preoperative WOMAC score, depression, and obesity were associated with worse one-year pain and function. Patients prescribed preoperative opioids had worse WOMAC scores one-year after TKA respectively when compared to non-opioid users, after adjusting for other factors (opioid user pain score: −9.5, function score: −9.4, opioid exposed pain score: −2.6, function score: −3.6, p < 0 .001 for all). Further, opioid users with a concomitant diagnosis of depression had significantly worse one-year postoperative WOMAC scores when compared to non-depressed non-opioid users (scores −14, p < 0 .001 for both pain and function).

In Alberta, 31% of patients were prescribed opioids within 180-days before TKA, preoperative opioid use was associated with worse one-year postoperative WOMAC pain and function scores relative to non-opioid users. Our results suggest that strategies to reduce preoperative opioid use could improve patient outcomes after TKA, and support the most recent Canadian opioid prescribing guidelines that attempt to minimize opioid use for chronic conditions such as arthritis.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 45 - 45
1 Feb 2020
Delgadillo L Jones H Noble PC
Full Access

Background

Cementless Total Knee Arthroplasty has been developed to reduce the incidence of failure secondary to aseptic loosening, osteolysis and stress-induced osteopenia, especially in younger and more active patients. However, failures are still more common compared to cemented components, especially those involving the tibia. It is hypothesized that this is caused by incomplete contact between the tibial tray and the underlying bony surface due to: (i) inadequate flatness of the tibial osteotomy, or (ii) failure of implantation to spread the area of contact over the exposed cancellous surface. In the present study we compare the contact area developed during implantation of a cementless tray as a function of the initial flatness of the tibial osteotomy.

Method

Eight joint replacement surgeons prepared 14 cadaveric knees for cementless TKR using a standard instrumentation set (ZimmerBiomet Inc). The tibial osteotomy was created using an oscillating bone saw and a 1.27mm blade (Stryker Inc) directed by a slotted cutting guide mounted on an extramedullary rod and fixed to the tibia with pins and screws. The topography of the exposed cancellous surface was captured with a commercial laser scanner (Faro Inc, Halifax, approx. 33,000 surface points). 3D computer models of each tibial surface were generated in a CAD environment (Rapidform, Inuus). After scanning, a cementless tibial tray was implanted on the prepared tibial surface using a manual impactor. The tray-tibia constructs were dissected free of soft tissue, embedded in mounting resin, and sectioned with a diamond wafering saw. Points of bone-tray contact and interface separation were identified by stereomicroscopy and incorporated in the 3D computer models. Maps were generated depicting contacting and non-contacting areas Each model was subdivided into 7 zones for characterizing the distribution of interface contact in terms of anatomic location.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 48 - 48
1 Feb 2020
Jones H Foley E Garrett K Noble P
Full Access

Introduction

Corrosion products from modular taper junctions are a potent source of adverse tissue reactions after THR. In an attempt to increase the area of contact and resistance to interface motion in the face of taper mismatches, neck trunnions are often fabricated with threaded surfaces designed to deform upon assembly. However, this may lead to incomplete contact and misalignment of the head on the trunnion, depending upon the geometry and composition of the mating components. In this study we characterized the effect of different femoral head materials on the strength and area of contact of modular taper constructs formed with TiAlV trunnions.

Materials and Methods

Three groups of 36mm femoral heads (CoCr, Biolox ceramic; Oxinium) and matching Ti-6Al-4V rods with 12/14 trunnions were selected for use in this study. The surface of each trunnion was coated with a 20nm layer of gold applied by sputter-coating in vacuo. Each head/trunnion pair was placed in an alignment jig and assembled with a peak axial impaction force of 2000N using a drop tower apparatus. After assembly, each taper was disassembled in a custom apparatus mounted in a mechanical testing machine (Bionix. MTS. After separation of the components, the surface of each trunnion was examined with backscattered electron microscopy to reveal the area of disruption of the original gold-coated surface. Images encompassing the entire surface of the trunnion were collected and quantified by image processing.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 112 - 112
1 Feb 2020
Kreuzer S Madurawe C Pierrepont J Jones T
Full Access

Introduction

In total hip arthroplasty, correct sizing is critical for fixation and longevity of cementless components. Previously, three-dimensional CT templating has been shown to be more accurate than using 2D radiographs. The accuracy of the Optimized Positioning System (OPSTM) planning software has not been reported. The aim of this study was to measure the accuracy of the OPS planning software in predicting the implanted acetabular cup and femoral stem size when used with the direct anterior approach.

Method

Between October 2018 and March 2019, 95 patients received a bone preserving cementless MiniHip stem (Corin, UK). Sixty-three of these patients also received a cementless Trinity cup (Corin, UK). All patients were sent for OPSTM pre-operative planning, a patient-specific dynamic modelling software used to determine the optimal acetabular and femoral component size and positions. Average age was 57 (28 to 78) and 44% were female. All cases were performed using the direct anterior approach. The sizes of implants used were retrospectively compared to the planned OPSTM sizes.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 42 - 42
1 Feb 2020
Ismaily S Parekh J Han S Jones H Noble P
Full Access

INTRODUCTION

In theory, Finite Element Analysis (FEA) is an attractive method for elucidating the mechanics of modular implant junctions, including variations in materials, designs, and modes of loading. However, the credence of any computational model can only be established through validation using experimental data. In this study we examine the validity of such a simulation validated by comparing values of interface motion predicted using FEA with values measured during experimental simulation of stair-climbing.

MATERIALS and METHODS

Two finite element models (FEM) of a modular implant assembly were created for use in this study, consisting of a 36mm CoCr femoral head attached to a TiAlV rod with a 14/12 trunnion. Two head materials were modelled: CoCr alloy (118,706 10-noded tetrahedral elements), and alumina ceramic (124,710 10-noded tetrahedral elements). The quasi-static coefficients of friction (µs) of the CoCr-TiAlV and Ceramic-TiAlV interfaces were calculated from uniaxial assembly (2000N) and dis-assembly experiments performed in a mechanical testing machine (Bionix, MTS). Interface displacements during taper assembly and disassembly were measured using digital image correlation (DIC; Dantec Dynamics). The assembly process was also simulated using the computational model with the friction coefficient set to µs and solved using the Siemens Nastran NX 11.0 Solver. The frictional conditions were then varied iteratively to find the value of µ providing the closest estimate to the experimental value of head displacement during assembly.

To validate the FEA model, the relative motion between the head and the trunnion was measured during dynamic loading simulating stair-climbing. Each modular junction was assembled in a drop tower apparatus and then cyclically loaded from 230–4300N at 1 Hz for a total of 2,000 cycles. The applied load was oriented at 25° to the trunnion axis in the frontal plane and 10° in the sagittal plane. The displacement of the head relative to the trunnion during cyclic loading was measured by a three-camera digital image correlation (DIC) system. The same loading conditions were simulated using the FEA model using the optimal value of µ derived from the initial head assembly trials.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 136 - 136
1 Feb 2020
Greene A Parsons I Jones R Youderian A Byram I Papandrea R Cheung E Wright T Zuckerman J Flurin P
Full Access

INTRODUCTION

3D preoperative planning software for anatomic and reverse total shoulder arthroplasty (ATSA and RTSA) provides additional insight for surgeons regarding implant selection and placement. Interestingly, the advent of such software has brought previously unconsidered questions to light on the optimal way to plan a case. In this study, a survey of shoulder specialists from the American Shoulder and Elbow Society (ASES) was conducted to examine thought patterns in current glenoid implant selection and placement.

METHODS

172 ASES members completed an 18-question survey on their thought process for how they select and place a glenoid implant for both ATSA and RTSA procedures. Data was collected using a custom online Survey Monkey survey. Surgeon answers were split into three cohorts based on their responses to usage of 3D preoperative planning software: high users, seldom users, and non-users. Data was analyzed for each cohort to examine differences in thought patterns, implant selection, and implant placement.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 131 - 131
1 Feb 2020
Greene A Parsons I Jones R Youderian A Byram I Papandrea R Cheung E Wright T Zuckerman J Flurin P
Full Access

INTRODUCTION

The advent of CT based 3D preoperative planning software for reverse total shoulder arthroplasty (RTSA) provides surgeons with more data than ever before to prepare for a case. Interestingly, as the usage of such software has increased, further questions have appeared over the optimal way to plan and place a glenoid implant for RTSA. In this study, a survey of shoulder specialists from the American Shoulder and Elbow Society (ASES) was conducted to examine thought patterns in current RTSA implant selection and placement.

METHODS

172 ASES members completed an 18-question survey on their thought process for how they select and place a RTSA glenoid implant. Data was collected using a custom online Survey Monkey survey. Surgeon answers were split into two cohorts based on number of arthroplasties performed per year: between 0–75 was considered low volume (LV), and between 75–200+ was considered high volume (HV). Data was analyzed for each cohort to examine differences in thought patterns, implant selection, and implant placement.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 134 - 134
1 Feb 2020
Greene A Parsons I Jones R Youderian A Byram I Papandrea R Cheung E Wright T Zuckerman J Flurin P
Full Access

INTRODUCTION

3D preoperative planning software for anatomic total shoulder arthroplasty (ATSA) provides surgeons with increased ability to visualize complex joint relationships and deformities. Interestingly, the advent of such software has seemed to create less of a consensus on the optimal way to plan an ATSA rather than more. In this study, a survey of shoulder specialists from the American Shoulder and Elbow Society (ASES) was conducted to examine thought patterns in current ATSA implant selection and placement.

METHODS

172 ASES members completed an 18-question survey on their thought process for how they select and place an ATSA glenoid implant. Data was collected using a custom online Survey Monkey survey. Surgeon answers were split into two cohorts based on number of arthroplasties performed per year: between 0–75 was considered low volume (LV), and between 75–200+ was considered high volume (HV). Data was analyzed for each cohort to examine differences in thought patterns, implant selection, and implant placement.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 76 - 76
1 May 2019
Jones R
Full Access

In a recent study, 54.5% of patients reporting to arthroplasty clinics in the US were obese. We performed a recent literature review to determine how obesity impacts outcomes in total hip and knee arthroplasty and what must be done to improve outcomes in the obese arthroplasty patient.

Specifically, obese patients have shown increased rates of infection, dislocation, need for revision, wound dehiscence, increased operative time and prolonged hospital stay. Additionally, obese TKA patients have been shown to have increased rates of aseptic loosening, thromboembolic events, wound complications, and cardiopulmonary events.

Worsening severity of obesity seems to correlate with worsening outcomes and super obesity (BMI>50) has been identified as an independent risk factor for complications. Patients with BMI>35 have shown to be 6.7 times more likely to develop infection after TKA. Patients with BMI>40 have a 3.35 times higher rate of revision for deep infection than those with BMI<35. The odds ratio for major complications increases dramatically beyond BMI>45.

How can we improve outcomes in the obese patient? Preoperative care for the obese patient involves nutritional counseling, incorporating weight loss methods, physical therapy, metabolic workup and diagnosis and management of frequent comorbid conditions (OSA, DM2, HTN, HLD, malnutrition, renal failure). Identifying and managing comorbidities is especially important given that some comorbidities such as malnutrition have been shown to be as strong or even stronger an independent risk factor for postoperative TJA complications than obesity. In some cases higher complications were seen which some authors attribute to bariatric patients remaining in a catabolic state after weight loss.  

We know that obesity and its associated comorbid conditions do have worse outcomes and increased complications in TJA patients. We also know that complications proportionately increase with increasing severity of obesity. The super-obese population is at the greatest risk of complication following TJA and preoperative screening and management is essential in reducing complications. Although weight loss is important, bariatric data has shown that it does not solve the problem of obesity in itself and the patient's metabolic state is likely a more important issue. Implant selection is important and strong consideration should be given to avoiding direct anterior approach in the THA obese patient. Understanding of obesity specific complications and treatment options is crucial for patient counseling and optimization to ensure successful treatment in obese TJA patients.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 42 - 42
1 May 2019
Jones R
Full Access

The development of more wear resistant biomaterials and better locking mechanisms for the polyethylene into the tibial base has significantly reduced polyethylene wear as a reason for revision TKA. Aseptic loosening is now the primary cause for revision TKA. Loosening can be caused by multifactorial operative issues: 1] patient selection, 2] implant alignment, 3] cementing technique. Furthermore, aseptic loosening occurs at a consistent rate over time. Increased cement penetration is important to counter bone resorption. Increasing penetration also improves cement mantle toughness leading to better mechanical integrity of the bone-cement interface and reduces bone-cement interface stress.

It is important to recognise that a cleaner and drier interface does improve bone-cement penetration. Techniques to improve the process include better cement formulations, drilling sclerotic bone, devices and implant features to increase pressurization, using negative pressure suction ports in the tibia. We have extensive experience with CarboJet, a method of CO2 gas jet cleaning and drying. This experience was developed during 20 years of performing TKA with NO tourniquet. Schnetler et al found that the “use of a tourniquet in TKA causes a paradoxical increase in total blood loss”. So, NO tourniquet TKA is becoming the new paradigm for knee arthroplasty in reconstructive orthopaedics. Goldstein reported that pressurised carbon dioxide jet lavage resulted in a 35% increase in cement penetration depth when used vs. use of pulsatile saline lavage alone. Meneghini used this pressurised carbon dioxide system to study the influence of NO tourniquet use in TKA. He found a significant lowering of opioid consumption postoperatively.

Another important factor in increasing the cement interdigitation is the influence of lipids which significantly weakens the bond at the interfaces. If motion is allowed during cementation there is additional loss of penetration and therefore fixation. The pressurised carbon dioxide delivered by the CarboJet system actually pushes the lipid, fatty marrow up and out of the bone allowing it to be suctioned or lap dried from the interface surface. The NO tourniquet technique and the use of carbon dioxide jet gas delivery to improve the bone-cement interface in TKA will be demonstrated.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 118 - 118
1 Apr 2019
McKenna R Jacobs H Jones C Redgment A Talbot S Walter W Brighton R
Full Access

Introduction

In total knee arthroplasty, the aim is to relieve pain and provide a stable, functional knee. Sagittal stability is crucial in enabling a patient to return to functional activities. Knee implants with a medial pivot (MP) design are thought to more accurately reproduce the mechanics of the native joint, and potentially confer greater antero-posterior stability through the range of flexion than some other implant designs.

Aim

This study aims to compare the sagittal stability of four different total knee arthroplasty implant designs. Method

Comparison was made between four different implant designs: medial pivot (MP), two different types of cruciate retaining (CR1 and CR 2) and deep dish (DD). A cohort of 30 Medial Pivot (MP) knees were compared with matched patients from each of the other designs, 10 in each group. Patients were matched for age, body mass index and time to follow up.

Clinical examination was carried out by an orthopaedic surgeon blinded to implant type, and sagittal stability was tested using a KT1000 knee arthrometer, applying 67N of force at 30˚ and 90˚.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 48 - 48
1 Apr 2019
Etchels L Wang L Al-Hajjar M Williams S Thompson J Fisher J Wilcox R Jones A
Full Access

INTRODUCTION

There is great potential for the use of computational tools within the design and test cycle for joint replacement devices.

The increasing need for stratified treatments that are more relevant to specific patients, and implant testing under more realistic, less idealised, conditions, will progressively increase the pre-clinical experimental testing work load. If the outcomes of experimental tests can be predicted using low cost computational tools, then these tools can be embedded early in the design cycle, e.g. benchmarking various design concepts, optimising component geometrical features and virtually predicting factors affecting the implant performance. Rapid, predictive tools could also allow population-stratified scenario testing at an early design stage, resulting in devices which are better suited to a patient-specific approach to treatment.

The aim of the current study was to demonstrate the ability of a rapid computational analysis tool to predict the behaviour of a total hip replacement (THR) device, specifically the risk of edge loading due to separation under experimental conditions.

METHODS

A series of models of a 36mm BIOLOX® Delta THR bearing (DePuy Synthes, Leeds, UK) were generated to match an experimental simulator study which included a mediolateral spring to cause lateral head separation due to a simulated mediolateral component misalignment of 4mm. A static, rigid, frictionless model was implemented in Python (PyEL, runtime: ∼1m), and results were compared against 1) a critically damped dynamic, rigid, FE model (runtime: ∼10h), 2) a critically damped dynamic, rigid, FE model with friction (µ = 0.05) (runtime: ∼10h), and 3) kinematic experimental test data from a hip simulator (ProSim EM13) under matching settings (runtime: ∼6h). Outputs recorded were the variation of mediolateral separation and force with time.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 119 - 119
1 Apr 2019
McKenna R Marsden-Jones D Walter W
Full Access

Introduction

Component positioning is of great importance in total hip arthroplasty (THA) and navigation systems can help guide surgeons in the optimal placement of the implants. We report on a newly developed navigation system which employs an inertial measurement unit (IMU) to measure acetabular cup inclination and anteversion.

Aims

To assess the accuracy of the IMU when used for acetabular cup placement and compare this with an established optical navigation system (ONS).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 23 - 23
1 Apr 2019
Greene A Hamilton M Polakovic S Mohajer N Youderian A Wright T Parsons I Saadi P Cheung E Jones R
Full Access

INTRODUCTION

Variability in placement of total shoulder arthroplasty (TSA) glenoid implants has led to the increased use of 3D CT preoperative planning software. Computer assisted surgery (CAS) offers the potential of improved accuracy in TSA while following a preoperative plan, as well as the flexibility for intraoperative adjustment during the procedure. This study compares the accuracy of implantation of reverse total shoulder arthroplasty (rTSA) glenoid implants using a CAS TSA system verses traditional non-navigated techniques in 30 cadaveric shoulders relative to a preoperative plan from 3D CT software.

METHODS

High resolution 1mm slice thickness CT scans were obtained on 30 cadaveric shoulders from 15 matched pair specimens. Each scan was segmented and the digital models were incorporated into a preoperative planning software. Five fellowship trained orthopedic shoulder specialists used this software to virtually place a rTSA glenoid implant as they deemed best fit in six cadavers each. The specimens were randomized with respect to side and split into a cohort utilizing the CAS system and a cohort utilizing conventional instrumentation, for a total of three shoulders per cohort per surgeon. A BaSO4 PEEK surrogate implant identical in geometry to the metal implant used in the preoperative plan was used in every specimen, to maintain high CT resolution while minimizing CT artifact. The surgeons were instructed to implant the rTSA implants as close to their preoperative plans as possible for both cohorts. In the CAS cohort, each surgeon used the system to register the native cadaveric bones to each respective CT, perform the TSA procedure, and implant the surrogate rTSA implant. The surgeons then performed the TSA procedure on the opposing side of the matched pair using conventional instrumentation.

Postoperatively, CT scans were repeated on each specimen and segmented to extract the digital models. The pre- and postoperative scapulae models were aligned using a best fit match algorithm, and variance between the virtual planned position of the implant and the executed surgical position of the implant was calculated [Fig 1].


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 76 - 76
1 Apr 2019
Vasiljeva K Al-Hajjar M Lunn D Chapman G Redmond A Flatters I Thompson J Jones A
Full Access

Introduction

One of the known mechanisms which could contribute to the failure of total hip replacements (THR) is edge contact. Failures associated with edge contact include rim damage and lysis due to altered loading and torques. Recent study on four THR patients showed that the inclusion of pelvic motions in a contact model increased the risk of edge contact in some patients. The aim of current study was to determine whether pelvic motions have the same effect on contact location for a larger patient cohort and determine the contribution of each of the pelvic rotations to this effect.

Methods

Gait data was acquired from five male and five female unilateral THR patients using a ten camera Vicon system (Oxford Metrics, UK) interfaced with twin force plates (AMTI) and using a CAST marker set. All patients had good surgical outcomes, confirmed by patient-reported outcomes and were considered well-functioning, based on elective walking speed. Joint contact forces and pelvic motions were obtained from the AnyBody modelling system (AnyBody Technologies, DK). Only gait cycle regions with available force plate data were considered. A finite element model of a 32mm head on a featureless hemispherical polyethylene cup, 0.5mm radial clearance, was used to obtain the contact area from the contact force. A bespoke computational tool was used to analyse patients' gait profiles with and without pelvic motions. The risk of edge contact was measured as a “centre proximity angle” between the cup pole and centre of the contact area, and “edge proximity angle” between the cup pole and the furthest contact area point away from the pole. Pelvic tilt, drop and internal-external rotation were considered one at a time and in combinations.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 113 - 113
1 Apr 2019
Verstraete M Conditt M Wright T Zuckerman J Youderian A Parsons I Jones R Decerce J Goodchild G Greene A Roche C
Full Access

Introduction & Aims

Over the last decade, sensor technology has proven its benefits in total knee arthroplasty, allowing the quantitative assessment of tension in the medial and lateral compartment of the tibiofemoral joint through the range of motion (VERASENSE, OrthoSensor Inc, FL, USA). In reversal total shoulder arthroplasty, it is well understood that stability is primarily controlled by the active and passive structures surrounding the articulating surfaces. At current, assessing the tension in these stabilizing structures remains however highly subjective and relies on the surgeons’ feel and experience. In an attempt to quantify this feel and address instability as a dominant cause for revision surgery, this paper introduces an intra-articular load sensor for reverse total shoulder arthroplasty (RTSA).

Method

Using the capacitive load sensing technology embedded in instrumented tibial trays, a wireless, instrumented humeral trial has been developed. The wireless communication enables real-time display of the three-dimensional load vector and load magnitude in the glenohumeral joint during component trialing in RTSA. In an in-vitro setting, this sensor was used in two reverse total shoulder arthroplasties. The resulting load vectors were captured through the range of motion while the joint was artificially tightened by adding shims to the humeral tray.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 63 - 63
1 Apr 2019
Greene A Cheung E Polakovic S Hamilton M Jones R Youderian A Wright T Saadi P Zuckerman J Flurin PH Parsons I
Full Access

INTRODUCTION

Preoperative planning software for anatomic total shoulder arthroplasty (ATSA) allows surgeons to virtually perform a reconstruction based off 3D models generated from CT scans of the glenohumeral joint. The purpose of this study was to examine the distribution of chosen glenoid implant as a function of glenoid wear severity, and to evaluate the inter-surgeon variability of optimal glenoid component placement in ATSA.

METHODS

CT scans from 45 patients with glenohumeral arthritis were planned by 8 fellowship trained shoulder arthroplasty specialists using a 3D preoperative planning software, planning each case for optimal implant selection and placement. The software provided three implant types: a standard non-augmented glenoid component, and an 8° and 16° posterior augment wedge glenoid component. The software interface allowed the surgeons to control version, inclination, rotation, depth, anterior- posterior and superior-inferior position of the glenoid components in 1mm and 1° increments, which were recorded and compared for final implant position in each case.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 64 - 64
1 Apr 2019
Greene A Cheung E Polakovic S Hamilton M Jones R Youderian A Wright T Saadi P Zuckerman J Flurin PH Parsons I
Full Access

INTRODUCTION

Preoperative planning software for reverse total shoulder arthroplasty (RTSA) allows surgeons to virtually perform a reconstruction based off 3D models generated from CT scans of the glenohumeral joint. While anatomical studies have defined the range of normal values for glenoid version and inclination, there is no clear consensus on glenoid component selection and position for RTSA. The purpose of this study was to examine the distribution of chosen glenoid implant as a function of glenoid wear severity, and to evaluate the inter-surgeon variability of optimal glenoid component placement in RTSA.

METHODS

CT scans from 45 patients with glenohumeral arthritis were planned by 8 fellowship trained shoulder arthroplasty specialists using a 3D preoperative planning software, planning each case for optimal implant selection and placement. The software provided four glenoid baseplate implant types: a standard non-augmented component, an 8° posterior augment wedged component, a 10° superior augment wedged component, and a combined 8° posterior and 10° superior wedged augment component. The software interface allowed the surgeons to control version, inclination, rotation, depth, anterior-posterior and superior-inferior position of the glenoid components in 1mm and 1° increments, which were recorded and compared for final implant position in each case.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 124 - 124
1 Jun 2018
Jones R
Full Access

The development of more wear resistant biomaterials and better locking mechanisms for the polyethylene into the tibial base has significantly reduced polyethylene wear as a reason for revision TKA. Aseptic loosening is now the primary cause for revision TKA. Loosening can be caused by multifactorial operative issues: 1] patient selection, 2] implant alignment, 3] cementing technique. Furthermore, aseptic loosening occurs at a consistent rate over time. Increased cement penetration is important to counter bone resorption. Increasing penetration also improves cement mantle toughness leading to better mechanical integrity of the bone-cement interface and reduces bone-cement interface stress.

It is important to recognise that a cleaner and drier interface does improve bone-cement penetration. Techniques to improve the process include better cement formulations, drilling sclerotic bone, devices and implant features to increase pressurization, using negative pressure suction ports in the tibia. We have extensive experience with CarboJet, a method of CO2 gas jet cleaning and drying. This experience was developed during 20 years of performing TKA with NO tourniquet. Schnetler et al found that the “use of a tourniquet in TKA causes a paradoxical increase in total blood loss”. So, NO tourniquet TKA is becoming the new paradigm for knee arthroplasty in reconstructive orthopaedics. Goldstein reported that pressurised carbon dioxide jet lavage resulted in a 35% increase in cement penetration depth when used versus use of pulsatile saline lavage alone.

Another important factor in increasing the cement interdigitation is the influence of lipids which significantly weakens the bond at the interfaces. If motion is allowed during cementation there is additional loss of penetration and therefore fixation. The pressurised carbon dioxide delivered by the CarboJet system actually pushes the lipid, fatty marrow up and out of the bone allowing it to be suctioned or lap dried from the interface surface. The NO tourniquet technique and the use of carbon dioxide jet gas delivery to improve the bone-cement interface in TKA will be demonstrated.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 102 - 102
1 Jun 2018
Jones R
Full Access

Total knee arthroplasty (TKA) is one of the most common orthopaedic operations performed worldwide and it is largely successful in pain relief and functional recovery. However, when pain persists post-operatively the thorough evaluation must be instituted. Extra-articular causes of knee pain include; hip pathology, lumbar spine degenerative disease or radicular symptoms, focal neuropathy, vascular disease, and chronic regional pain syndrome. Intra-articular causes of knee pain: infection, crepitation/clunk, patella osteonecrosis, patella mal-tracking, soft tissue imbalance, malalignment, arthrofibrosis, component loosening, implant wear, ilio-tibial band irritation, and bursitis. Other causes of pain to rule out are component overhang with soft tissue irritation, recurrent hemarthrosis secondary to synovial impingement or entrapment, non-resurfaced patella, and metal sensitivity.

A careful history may reveal previous knee surgeries with delayed healing or prolonged drainage, chronology of sign and symptoms, co-morbid medical conditions, jewel or metal sensitivity.

Physical exam should help with specific signs in the operated knee. Targeted local anesthetic blocks are helpful and response to lumbar sympathetic blocks determines presence of CRPS.

Lab tests are important: ESR, CRP, WBC, aspiration with manual cell count and diff, leucocyte esterase dipstick, RA titers, metal derm patch testing, nuclear scans, CT best for rotational malalignment, and MARS MRI.

More recently patient satisfaction as an outcome measure has shown TKA results not satisfactory in 11- 18% of patients. A discordance of patient vs. surgeon satisfaction exists so the following factors may help improve this: correct patient selection, establishing and correlating surgeon-patient expectations, peri-operative optimization of patient co-morbidities to help avoid preventable complications, use of pre-operative and post-operative pathways. Satisfaction rates can best be improved by addressing the previous points with patients prior to TKA surgery.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_7 | Pages 7 - 7
1 May 2018
Rodger M Davis N Griffiths-Jones W Lee A
Full Access

A patient in his thirties developed synovitis with grade 4 chondrolysis and a stiff knee with a fixed flexion deformity between three and six years following PLC and PCL reconstruction using LARS (Ligament Augmentation and Reconstruction System, Corin). There was histologic evidence of foreign body reaction, the knee was painful, swollen and stiff.

We did not use any further LARS ligaments for soft tissue reconstructions of the kneein our practice. We commenced a recall programme for all 83 patients patients who underwent a soft tissue knee reconstruction using LARS. Of those contacted, 41 replied (49%) and 16 patients had symptoms (19%) and were investigated further with XRay, MRI and arthroscopy as indicated.

We discovered a total of five patients had histologically proven synovitis with foreign body reactions (6%), three of whom had life-changing symptomatic pain, swelling and stiffness with degenerate changes (3.6%). These patients had undergone various reconstructions, including a) PLC only, b) ACL and PCL, c) PCL and PLC and d) ACL, PCL and PLC. A further single case of massive bone cyst formation was noted, following PCL reconstruction using LARS (1.2%).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 18 - 18
1 Apr 2018
Preutenborbeck M Holub O Anderson J Jones A Hall R Williams S
Full Access

Introduction

Up to 60% of total hip arthroplasties (THA) in Asian populations arise from avascular necrosis (AVN), a bone disease that can lead to femoral head collapse. Current diagnostic methods to classify AVN have poor reproducibility and are not reliable in assessing the fracture risk. Femoral heads with an immediate fracture risk should be treated with a THA, conservative treatments are only successful in some cases and cause unnecessary patient suffering if used inappropriately. There is potential to improve the assessment of the fracture risk by using a combination of density-calibrated computed tomographic (QCT) imaging and engineering beam theory. The aim of this study was to validate the novel fracture prediction method against in-vitro compression tests on a series of six human femur specimens.

Methods

Six femoral heads from six subjects were tested, a subset (n=3) included a hole drilled into the subchondral area of the femoral head via the femoral neck (University of Leeds, ethical approval MEEC13-002). The simulated lesions provided a method to validate the fracture prediction model with respect of AVN.

The femoral heads were then modelled by a beam loaded with a single joint contact load. Material properties were assigned to the beam model from QCT-scans by using a density-modulus relationship. The maximum joint loading at which each bone cross-section was likely to fracture was calculated using a strain based failure criterion.

Based on the predicted fracture loads, all six femoral heads (validation set) were classified into two groups, high fracture risk and low fracture risk (Figure 1). Beam theory did not allow for an accurate fracture load to be found because of the geometry of the femoral head. Therefore the predicted fracture loads of each of the six femoral heads was compared to the mean fracture load from twelve previously analysed human femoral heads (reference set) without lesions.

The six cemented femurs were compression tested until failure. The subjects with a higher fracture risk were identified using both the experimental and beam tool outputs.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 35 - 35
1 Apr 2018
Al-Hajjar M Lancaster-Jones OO Ali M Jennings L Williams S Fisher J
Full Access

Introduction and Aims

There are many surgical, implant design and patient factors that should be considered in preclinical testing of hip replacement which are not being considered in current standards. The aim of this study was to develop a preclinical testing method that consider surgical positioning, implant design and patient factors and predict the occurrence and severity of edge loading under the combination of such conditions. Then, assess the safety and reliability of the implant by predicting the wear, deformation and damage of the implant bearings under worst case conditions.

Methods

Ceramic-on-ceramic (CoC, 36mm, BIOLOX® delta, Pinnacle®, DePuy Synthes, UK) and metal-on polyethylene (MoP, 36mm, Marathon®, Pinnacle®, DePuy Synthes, UK) bearings were used for this study on multi-station multi-axis hip joint simulators. Two factors were varied, cup inclination angles (45° and 65°) and translational mismatch between the femoral head and acetabular cup (0, 2, 3 and 4 (mm)). Under each condition for both CoC and MoP bearings, three million cycles of gait cycle testing were completed with wear, deformation and/or damage measurements completed at one million cycle intervals. Other outputs of the study were the level of dynamic separation between the femoral head and acetabular cup during gait, the maximum force at the rim during edge loading when the head was sliding back to the cup confinement. Means and 95% confidence limits were determined and statistical analysis were done using one way ANOVA with significance taken at p<0.05.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 53 - 53
1 Apr 2018
Cooper R Williams S Mengoni M Jones A
Full Access

Introduction

Geometric variations of the hip joint can give rise to repeated abnormal contact between the femur and acetabular rim, resulting in cartilage and labrum damage. Population-based geometric parameterisation can facilitate the flexible and automated in silico generation of a range of clinically relevant hip geometries, allowing the position and size of cams to be defined precisely in three dimensions. This is advantageous compared to alpha angles, which are unreliable for stratifying populations by cam type. Alpha angles provide an indication of cam size in a single two-dimensional view, and high alpha angles have been observed in asymptomatic individuals.

Parametric geometries can be developed into finite element models to assess the potential effects of morphological variations in bone on soft tissue strains. The aim of this study was to demonstrate the capabilities of our parameterisation research tool by assessing impingement severity resulting from a range of parametrically varied femoral and acetabular geometries.

Methods

Custom made MATLAB (MathWorks) and Python codes[1] were used to generate bone surfaces, which were developed into finite element models in Abaqus (SIMULIA). Parametric femoral surfaces were defined by a spherical proximal head and ellipse sections through the neck/cam region. This method produced surfaces that were well fitted to bone geometry segmented from CT scans of cam patients and capable of producing trends in results similar to those found using segmented models. A simplified spherical geometry, including the labrum and acetabular cartilage, represented the acetabulum.

Femoral parameters were adjusted to define relevant variations in cam size and position. Two radii (small and large cams) and two positions (anterior and superior cams) were defined resulting in four models. Alpha angles of these parametric femurs were measured in an anterior-posterior view and a cross-table lateral view using ImageJ (NIH). A further model was developed using a femur with a medium cam size and position, and the level of acetabular coverage and labrum length were varied.

Bones were modelled as rigid bodies and soft tissues were modelled as transversely isotropic linearly elastic materials. With the acetabulum fully constrained in all cases, the femurs were constrained in translation and rotated to simulate flexion followed by internal rotation to cause impingement against the labrum.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 1 - 1
1 Nov 2017
Lokikere N Syam K Saraogi A Siney P Nagai H Jones HW
Full Access

Introduction

Osteosynthesis to conserve femoral head following neck of femur (NOF) fractures has reported failure rates of 36 to 47% at 2 years. However, the long-term outcomes of THAs performed for failed osteosynthesis is yet to be elucidated. This study aims to report on long term outcome of primary THAs post failed osteosynthesis for NOF fracture.

Methods

Consecutive patients with THA for failed NOF osteosynthesis managed by a single unit between January 1974 and December 2009 were included. Clinical and radiological outcomes of all 72 patients were analysed. Patients with minimum follow-up of 5 years were included. Those with less than 5 years of follow-up were reviewed for failures.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 2 - 2
1 Nov 2017
Unnikrishnan PN Oakley J Wynn-Jones H Shah N
Full Access

The ideal operative treatment of displaced sub capital femoral fractures in the elderly is controversial. Recently, randomised controlled trials have suggested a better outcome with the use of total hip arthroplasty (THA) to treat displaced intra capsular fractures of the femur for elderly patients in good health. More recently the concept of dual mobility cups is being promoted to avoid dislocations in this cohort of patients. However, overall there is limited evidence to support the choice between different types of arthroplasty. Dislocation remains a main concern with THA, especially when a posterior approach is used.

We analysed the outcome of 115 primary THR (112 cements and 3 uncemented) THR using a posterior approach with soft tissue repair in active elderly patients presenting with displaced intra capsular femoral neck fractures. Size 28 mm head was used in 108 and a size 32 mm head in the rest. All surgery was performed by specialist hip surgeons.

Satisfactory results were noted in terms of pain control, return to pre-morbid activity and radiological evidence of bone implant osteo-integration. The 30-day mortality was nil. There were two dislocations and only one needed revision surgery due to recurrent dislocation.

In conclusion, with optimal patient selection, THA seems to provide a good functional outcome and pain relief in the management of displaced intracapsular femoral neck fractures. Excellent outcome can be achieved when done well using the standard cemented THR and with 28mm head. A good soft tissue repair and a specialist hip surgeon is preferable.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 24 - 24
1 Nov 2017
Saraogi A Lokikere N Lafferty R Nagai H Pavlou G Board T Jones HW
Full Access

Prosthetic joint infection continues to remain a diagnostic challenge for unhappy primary arthroplasty of hip and knees. There is increasing dependence upon alpha-defensin test to make key decisions like whether to revise or not & to decide between one-stage versus two-stage.

Aim

This study aims to assess diagnostic accuracy of alpha-defensin test in determining prosthetic hip & knee infection and to provide guidance for appropriate use of this novel but expensive investigation.

Methods

Retrospective review of all alpha-defensin investigated patients in an orthopaedic institute between February 2015 & March 2017 was performed. Clinical and radiological outcomes including re-infections, re-operations were analysed and alpha-defensin outcomes were compared with that of other available investigations.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 8 - 8
1 Nov 2017
Patel M Aujla R Jones A Bhatia M
Full Access

Background

Conservative treatment of acute AT ruptures with functional rehabilitation has demonstrated superior results with equal reported re-rupture rates but without the added complications of surgical treatment.

There is no consensus on the duration and method of treatment using functional rehabilitation regimes.

The purpose of this paper is to define our treatment regime, the Leicester Achilles Management Protocol (LAMP), supported with patient reported outcomes and objective measures of assessment.

Methods

All patients with an acute achilles tendon rupture were treated with the same non-operative LAMP functional rehabilitation regime in a VACOped boot for 8 weeks. 12 months post rupture ATRS scores and objective measures of calf muscle girth and heel raise height were obtained and analysed. Venous thromboembolic rates and rates of re-rupture were recorded.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 10 - 10
1 Nov 2017
Sidharthan S Lokikere N Saraogi A Nagai H Wynn-Jones H Board T Shah N Porter M Kay P
Full Access

Background

One of the major concerns of hinge knees have been reported in literature is mechanical failure. Failure in the form of component fracture (2–10%) and hinge dislocation/ failure are worrisome. In addition, higher risk of aseptic loosening with hinge knee prosthesis has been attributed to stress transfer at bone cement interface.

Methods

Retrospective review of clinical and radiological results of 71 consecutive patients operated at single centre using Smiles hinge knee (Stanmore implants) between 2010 and 2014. Data was collected till the latest follow up. Mechanical failure due to any reason was considered as primary end point. Radiological evidence of aseptic loosening was considered to be one of the surrogate end points.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_16 | Pages 9 - 9
1 Oct 2017
Abdul W Goodson M Jones SA
Full Access

Dislocation and instability remain leading cause of failure following THA. We present a single-surgeon 10-year experience with use of Dual Mobility (DM) bearings in Primary and Revision THA using posterior approach.

127 DM bearings were implanted between September 2006 – September 2016; 102 in high-risk primary THA's and 25 revision THA's for either treatment or prevention of instability. Selection for DM bearing followed individual patient risk assessment. Criteria for use of DM bearing were presence of multiple risk factors.

Mean age was 72.9 years. 100 Mono-block DM implants, 22 Modular DM implants and 5 custom-made DM devices were implanted. Revision cohort included those used in conjunction with a cage or porous metal augments. 2 dislocations (1.6%) were observed, both in the Revision group, 1 was recurrent requiring revision to constrained liner. Primary group had 2 revisions; 1 peri-prosthetic fracture and 1 deep infection. No DM bearing specific complications were observed. A constructed life table calculated survival function with endpoint set as revision for any reason demonstrated a cumulative survival of 94% at 7.4 years.

In high-risk patients, DM bearings are successful at preventing and treating dislocation in THA. Primary cohort in this study all had multiple risk factors for instability but no dislocations or bearing specific complications were observed. Dislocations observed in Revision group were associated with major soft tissue deficiency.

This study adds to the promising results already reported with DM THA articulations and should be considered for patients at risk of dislocation or instability.

Runner Up – Best Paper Award


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 87 - 87
1 Aug 2017
Jones R
Full Access

The US obesity epidemic has transcended into the arthroplasty patient population and surgeons must assess whether obesity is a risk factor for poor outcomes in total joint arthroplasty (TJA) and determine how it should be managed in order to insure good clinical outcomes. In the United States, 34.9% of adults are currently obese (BMI > 30). In a recent study, 54.5% of patients reporting to arthroplasty clinics in the US were obese. We performed a recent literature review to determine how obesity impacts outcomes in total hip and knee arthroplasty and what must be done to improve outcomes in the obese arthroplasty patient.

We know that obesity and its associated comorbid conditions do have worse outcomes and increased complications in TJA patients. We also know that complications proportionately increase with increasing severity of obesity. The super-obese population is at the greatest risk of complication following TJA and pre-operative screening and management is essential in reducing complications. Although weight loss is important, our bariatric data has shown that it does not solve the problem of obesity in itself and the patient's metabolic state is likely a more important issue. Implant selection is important and strong consideration should be given to avoiding direct anterior approach in the THA obese patient. Understanding of obesity specific complications and treatment options is crucial for patient counseling and optimisation to ensure successful treatment in obese TJA patients.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 51 - 51
1 Aug 2017
Jones R
Full Access

TKA is one of the most common orthopaedic operations performed worldwide and it is largely successful in pain relief and functional recovery. However, when pain persists post-operatively the thorough evaluation must be instituted. Extra-articular causes of knee pain include; hip pathology, lumbar spine degenerative disease or radicular symptoms, focal neuropathy, vascular disease, and chronic regional pain syndrome. Intra-articular causes of knee pain: infection, crepitation/ clunk, patella osteonecrosis, patella mal-tracking, soft tissue imbalance, malalignment, arthrofibrosis, component loosening, implant wear, ilio-tibial band irritation, and bursitis. Other causes of pain to rule out are component overhang with soft tissue irritation, recurrent hemarthrosis secondary to synovial impingement or entrapment, non-resurfaced patella, and metal sensitivity.

A careful history may reveal previous knee surgeries with delayed healing or prolonged drainage, chronology of sign and symptoms, co-morbid medical conditions, jewel or metal sensitivity.

Physical exam should help with specific signs in the operated knee. Targeted local anesthetic blocks are helpful and response to lumbar sympathetic blocks determines presence of CRPS.

Lab tests are important: ESR, CRP, WBC, aspiration with manual cell count and diff, leukocyte esterase dipstick, RA titers, metal derm patch testing, nuclear scans, CT best for rotational malalignment,, and MARS MRI.

More recently patient satisfaction as an outcome measure has shown TKA results not satisfactory in 11 – 18% of patients. A discordance of patient vs. surgeon satisfaction exists so the following factors may help improve this: correct patient selection, establishing and correlating surgeon-patient expectations, peri-operative optimisation of patient comorbidities to help avoid preventable complications, use of pre- and post-operative pathways. Satisfaction rates can best be improved by addressing the previous points with patients prior to TKA surgery.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 117 - 117
1 Apr 2017
Jones R
Full Access

Functional restoration of patella kinematics is an essential component of TKA, whether the patella is replaced or not. This goal is accomplished by a multifactorial approach: establish proper component position and alignment, especially rotation; avoid IR of the femoral and ER of the tibial components; maintain correct joint line position; achieve symmetrical soft tissue balance.

Most modern TKA designs have an anatomic trochlear groove shape to enable midline tracking. Patella implants are better designed as well with three equilateral lugs for fixation and either dome or anatomic shape. The apex of the patella component should be aligned with the apex of the patella raphe which is more medial than lateral. This method leaves an island of exposed lateral patella facet which is managed with the “lateral slat technique” to be described. It is essentially an intraosseous lateral release. The early mobilization of modern TKA patients demands watertight closure to prevent soft tissue attenuation and late tracking issues.

When confronted with a patient with a laterally dislocated patella, implementation of the “lateral slat technique” should be done at the approach to obtain midline tracking. Such patients require a median parapatellar (MPP) approach and may need distal-lateral vastus medialis advancement (Insall procedure).

Adherence to the principles iterated herein will produce a happy patient with good patello-femoral kinematics and function.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 28 - 28
1 Apr 2017
Jones R
Full Access

As the American population ages and a trend toward performing total hip arthroplasty (THA) in younger patients continues, the number of Americans undergoing THA is projected to increase over time. The advent of the bundled payment system combined with the current medical utilization climate has placed considerable pressure on surgeons to produce excellent results with early functional recovery and short hospital stays. The US obesity epidemic has transcended into the arthroplasty patient population and surgeons must assess whether obesity is a risk factor for poor outcomes in THA and determine how it should be managed. We performed a recent literature review to determine how obesity impacts outcomes in total hip arthroplasty and what must be done to improve outcomes in the obese arthroplasty patient. Our goal is to answer 3 questions: does obesity increase the complication rate in THA, if obesity matters how obese is too obese, and what must be done to improve outcomes in the obese patient?

Ultimately, obesity has been shown to correlate with increased post-operative complications in THA. The arthroplasty surgeon must optimise the obese patient prior to surgery by identifying associated comorbidities and consider malnutrition screening with counseling. Notice should be taken of the degree of obesity as patients with BMI > 40 have demonstrated much higher complication rates. Strong consideration should be given to avoiding direct anterior approach in the obese patient. Healthy weight loss must be encouraged with appropriate patient counseling and treatment in order to achieve success with THA in obese patients.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 51 - 51
1 Apr 2017
Jones R
Full Access

The femur begins to bow anteriorly at the 200 mm level, but may bow earlier in smaller people. If the stem to be used is less than 200 mm, a straight stem can be used. If the stem is longer than 200 mm, it will perforate the anterior femoral cortex. I know this because I did this on a few occasions more than 20 years ago.

To use a long straight stem, there are two techniques. One can either do a diaphyseal osteotomy or one can do a Wagner split (extended trochanteric osteotomy). Both of these will put the knee in some degree of hyperextension, probably insignificant in the elderly, but it may be of significance in the young. In very young people, therefore, it may be preferable to use a bowed stem to avoid this degree of recurvatum.

There are two different concepts of loading. Diaphyseal osteotomy implies a proximal loading has been sought. The Wagner split ignores the proximal femur and seeks conical fixation in the diaphysis. There will be very little bone-bone contact between what remains of the attached femur and the detached anterior cortex so that it is important to ensure that the blood supply to the anterior cortex remains intact, preferably by using Wagner's technique, using a quarter-inch osteotome inserted through the vastus to crack the medial cortex. Current modularity is of two types. Distal modularity was attempted many years ago and was never successful.

Proximal modularity, as for example, the S-ROM stem, implies various sizes of sleeves fit onto the stem to get a proximal canal fill. In mid-stem modularity, the distal stem wedges into the cone. It has to be driven into where it jams and this can be somewhat unpredictable. For this reason, the solid Wagner stem has been replaced by the mid-stem modular. Once the distal femur is solidly embedded, the proximal body is then selected for height and version. The proximal body is unsupported in the mid-stem modular and initially, few fractures were noted at the taper junction. Cold rolling, shot peening and taper strengthening seem to have solved these problems.

There are a variety of types of osteotomy, which can be used for different deformities. With a mid-stem modular system, generally, all that needs to be done is a Wagner-type split and fixation is sought in the mid-diaphysis by conical reaming. No matter what stem is used, distal stability is necessary. This is achieved by flutes, which engage the endosteal cortex. The flutes alone must have sufficient rotational stability to overcome the service loads on the hip of 22 Nm.

I divide revision into three categories. In type one, the isthmus is intact, i.e. the bone below the lesser trochanter so that a primary stem can be used. In type two, the isthmus is damaged, i.e. the bone below the lesser trochanter, so a long revision stem is required. In a type three, there is more than 70 mm of missing proximal femur. The Wagner stem may be able to handle this on its own, but most other stems are better supported with a structural allograft cemented to the stem.

The reported long term results of mid-stem modular revision implants are good as in most, over 90% survivorship. The introduction of modularity appears to have overcome initial disadvantage of the Wagner stem, i.e. its unpredictability in terms of leg length.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 137 - 137
1 Mar 2017
Schaller G Waters T Davies N Whittingham-Jones P
Full Access

Introduction

Trabecular titanium implants are 3D printed with a high-friction ingrowth surface that is continuous with the rest of the acetabular shell. The ability to “face-change” following optimum seating of the component allows unprecedented levels of versatility in acetabular orientation. Bolt-on augments enable rapid trialling and definitive insertion of a monobloc construct. The use of these implants has rapidly increased in the National Joint Registry over the last three years with little published outcome data. We present one of the largest studies using this material.

Objectives

This study assesses the early stability, ingrowth and clinical outcome of revision acetabular reconstruction with trabecular titanium.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 60 - 60
1 Mar 2017
Lancaster-Jones OO Al-Hajjar M Williams S Jennings L Thompson J Isaac G Fisher J
Full Access

Introduction and Aims

Clinically many factors such as variations in surgical positioning, and patients' anatomy and biomechanics can affect the occurrence and severity of edge loading which may have detrimental effect on the wear and durability of the implant. Assessing wear of hundreds of combinations of conditions would be impractical, so a preclinical testing approach was followed where the occurrence and severity of edge loading can be determined using short biomechanical tests. Then, selected conditions can be chosen under which the wear can be determined. If a wear correlation with the magnitude of dynamic separation or the severity of edge loading can be shown, then an informed decision can be made based upon the biomechanical results to only select important variables under which the tribological performance of the implant can be assessed. The aim of this study was to determine the relationship between the wear of ceramic-on-ceramic bearings and the (1) magnitude of dynamic separation, (2) the maximum force reached during edge loading and (3) the severity of edge loading resulting from component translational mismatch between the head and cup centres.

Methods

The Leeds II hip joint simulator with a standard walking cycle and 36mm diameter ceramic-on-ceramic bearings (BIOLOX® delta, DePuy Synthes Joint Reconstruction, Leeds, UK.) were used. The study was in two parts. Part one: a biomechanical study where the dynamic separation, the maximum load during edge loading, and the duration of edge loading alongside the magnitude of forces under edge loading (severity of edge loading) were assessed. Part two; a wear study where the wear rates of the bearing surfaces were assessed under a series of input conditions. These input testing conditions included inclining the acetabular cups at 45° and 65° cup inclination angle (in-vivo equivalent), with 2, 3, and 4mm medial-lateral component mismatch between the centres of the head and the cup. This equated to six conditions being assessed, each with three repeats for the biomechanical test, and six repeats completed for the wear study.

The severity of edge loading was assessed as described in Equation 1.

Severity of Edge Loading = ∫tt0 F(x) dx + ∫tt0 F(y) dy … Equation 1,

where F(x) is the axial load, F(y) is the medial-lateral load and t-t0 is the duration of edge loading.

The wear of the ceramic bearings were determined using gravimetric analysis (XP205, Mettler Toledo, UK).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 58 - 58
1 Mar 2017
Noble P Patel R Jones H Kim R Gold J Ismaily S
Full Access

INTRODUCTION

Stable fixation of cementless tibial trays remains a challenge due bone density variability within the proximal tibia and the spectrum of loads imposed by different activities. This study presents a novel approach to measuring the interface motion of cementless tibial components during functional loading and tests whether interface motion of cementless tibial trays varies around the implant periphery.

METHODS

We developed a method to measure relative displacement of a tibial tray relative to the underlying bone using 3D digital image correlation (DIC) and multi-camera stereo photogrammetry. A clinically successful design of cementless total knee prosthesis (Zimmer Inc, Warsaw, IN) was implanted in 6 fresh cadaveric knees. A black-on-white stochastic pattern was applied to the outer surface of the tibia and the cementless prosthesis. High resolution digital images were prepared of the interface region and divided into 25 × 25 pixel regions of interest (ROI). Stereo images of the same ROI were generated using two cameras angled at 60 degrees using image correlation techniques. All specimens were mounted in a custom-built functional activity simulator and loaded with the forces and moments recorded during three common functional activities (standing from a seated position, walking, and stair descent), as reported in the Orthoload database, scaled by 50% for application to cadaveric bone. Prior to functional testing, each implant-tibia construct was preconditioned with 500 cycles of flexion from 5–100 degrees under a vertical tibial load of 1050 N at a frequency of 0.2 Hz. During loading, image data was acquired simultaneously (±20 μs) from the entire circumference of the tibial interface forming 4 stereo images using 8 cameras spaced at 90 degree intervals (Allied Vision Technologies, Exton, PA) using custom image acquisition software (Mathworks, Natick, MA) (Figure 1). The multiple stereo images were registered using the surface topography of each specimen as measured by laser scanning (FARO Inc., Montreal) (Figure 2). During post-processing, the circumferential tray/tibia interface was divided into 10 zones for subsequent analysis (Figure 3). Interface displacements were measured on a point-to-point basis at approximately 700 sites on each specimen using commercial DIC software (Dantec Dynamics, Skovlunde, Denmark) (Figure 4).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 123 - 123
1 Mar 2017
Roche C Greene A Flurin P Wright T Zuckerman J Jones R
Full Access

Introduction

Humeral radiolucent lines after anatomic TSA (aTSA) have been well described; however, little clinical consequences have been attributed to them. The recent emergence of shorter humeral stems has demonstrated higher incidences of humeral radiolucencies than has been reported historically with standard length components. This large scale database analysis quantifies and compares the clinical outcomes of aTSAs with and without radiolucent humeral lines using one specific prosthesis to determine their impact on clinical outcomes.

Methodology

This is a multicenter, retrospective, case controlled radiographic and clinical review. Preoperative and postoperative data was analyzed from 671 aTSA patients with a minimum of 2 years followup. 538 of these 671 aTSA patients had full radiographic followup (80.2%) and were included in this study; these patients had an average followup of 45.3 months). 459 patients had noncemented humeral stems; whereas, 79 patients had cemented humeral stems. Radiographs were reviewed at latest follow up for humeral radiolucent lines based on the technique described by Gruen et al. Patients were evaluated and scored pre-operatively and at latest follow-up using the SST, UCLA, ASES, Constant, and SPADI scoring metrics; ROM was also recorded. A Student's two-tailed, unpaired t-test was used to identify differences in pre-operative, post-operative, and improvement in results, where p<0.05 denoted a significant difference.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 53 - 53
1 Mar 2017
Navruzov T Van Der Straeten C Riviere C Jones G Cobb J Auvinet E
Full Access

Introduction

Hip resurfacing arthroplasty (HRA) is currently regaining positive attention as a treatment of osteoarthritis in young, active individuals[1]. The procedure is complex and has low tolerance for implant malpositioning [2]. ‘Precision tools', such as imageless navigation and patient specific instruments, have been developed to assist with implant positioning but have not been shown to be fully reliable [3]. The aim of this study is to present and validate the first step of novel quality control tool to verify implant position intra-operatively. We propose that, before reaming of the femoral head, a handheld structured light 3D scanner can be used to assess the orientation and insertion point of femoral guide wire.

Methods

Guide wires were placed into the heads of 29 solid foam synthetic femora. A specially designed marker (two orthogonal parallelepipeds attached to a shaft) was inserted into the guide wire holes. Each bone (head, neck and marker) was 3D scanned twice (fig 1). The insertion point and guide wire neck angle were calculated from the marker's parameters. Reference data was acquired with an optical tracking system. The measurements calculated with the 3D scans were compared to the reference ones to evaluate the precision. The comparison of the test retest measurements done with the new method are used to evaluate intra-rater variability.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 57 - 57
1 Mar 2017
Noble P Gold J Patel R Lenherr C Jones H Ismaily S Alexander J
Full Access

INTRODUCTION

Cementless tibial trays commonly fail through failure of fixation due to excessive interface motion. However, the specific combination of axial and shear forces precipitating implant failure is unknown. This has led to generic loading profiles approximating walking to perform pre-clinical assessment of new designs, even though telemetric data demonstrates that much larger forces and moments are generated during other functional activities. This study was undertaken to test the hypotheses: (i) interface motion of cementless tibial trays varies as a function of specific activities, and (ii) the response of the cementless tibial interface to walking loading is not representative of other functional activities.

MATERIALS and METHODS

Six fresh-frozen cadaveric tibias were tested using a custom designed functional activity simulator after implantation of a posterior stabilized total knee replacement (NexGen LPS, Zimmer, Warsaw IN). Activity scenarios were selected using force (Fx, Fy, Fz) and moment (Mx, My, Mz) data from patients with instrumented tibial trays (E-tibia) published by Bergmann et al. A pattern of black and white spray paint was applied to the surface of the specimen including the tibial tray and bone. Each specimen was preconditioned through application of a vertical load of 1050N for 500 cycles of flexion-extension from 5–100°. Following preconditioning, each tibia was loaded using e-tibia values of forces and moments for walking, stair-descent, and sit-to-stand activities. The differential motion of the tibial tray and the adjacent bony surface was monitored using digital image correlation (DIC) (resolution: 1–2 microns in plane; 3–4 microns out-of-plane). Four pairs of stereo-images of the tray and tibial bone were prepared at sites around the circumference of the construct in both the loaded and unloaded conditions: (i) before and after pre-conditioning and (ii) before and after the 6 functional loading profiles. The images were processed to provide circumferential measurements of interface motion during loading. Differences in micromotion and migration were evaluated statistically using step-wise multivariate regression.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 61 - 61
1 Mar 2017
Lancaster-Jones OO Al-Hajjar M Williams S Jennings L Thompson J Isaac G Fisher J
Full Access

Introduction and Aims

There are many variables that can affect the occurrence and severity of edge loading in hip replacement. A translational mismatch between the centres of rotation of the head and cup may lead to dynamic separation, causing edge loading and increased wear. Combining a steep inclination angle with such translational mismatch in the medial-lateral axis caused a larger magnitude of separation and increased severity of edge loading. Previous studies have shown variation in the hip Swing Phase Load (SPL) during gait between different patients. The aim of this study was to apply a translational mismatch and determine the effect of varying the SPL on the occurrence and severity of edge loading under different cup inclination angles in a hip joint simulator.

Methods

The Leeds II hip joint simulator with a standard gait cycle and 36mm diameter ceramic-on-ceramic bearings (BIOLOX® delta) were used in this study. The study was in two stages; [1] a biomechanical study where the magnitude of dynamic separation, the duration of edge loading and the magnitude of force under edge loading (severity) were assessed under variations in component positioning and SPLs. [2] A wear study to assess edge loading with selected input conditions. For the biomechanical study, a combination of four mismatches, three cup inclination angles, and eight SPLs (Table 1) were investigated. For the wear study, three SPL conditions were selected with one cup angle and one mismatch (Table 1). Three million cycles were completed under each condition. Mean wear rates and 95% confidence limits were determined and statistical analysis (one way ANOVA) completed (significance taken at p<0.05).

Table 1: Study matrix


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 21 - 21
1 Feb 2017
Hua X Wilcox R Fisher J Jones A
Full Access

INTRODUCTION

Mal-positioning of the acetabular component in total hip replacement (THR) could lead to edge loading, accelerated component wear, impingement and dislocation [1,2]. In order to achieve a successful position for the acetabular component, the assessment of the acetabular orientation with reference to different coordinate systems is important [3]. The aims of the present study were to establish a pelvic coordinate system and a global body coordinate system, and to assess the acetabular orientations of natural hips with reference to the two coordinate systems.

METHODS

Three-dimensional (3D) computed tomographic (CT) images of 56 subjects (28 males and 28 females) lying supine were obtained from a public image archive (Cancer Image Archive, website: www.cancerimagingarchive.net). 3D solid models of pelvis and spine were generated from the CT images. Two coordinate systems, pelvic and global body coordinate systems, were established. The pelvic coordinate system was established based on four bony landmarks on the pelvis: the bilateral anterior superior iliac spines (RASIS and LASIS) and the bilateral pubic tubercles (RPT and LPT). The global body coordinate system was generated based on the bony landmarks on the spine: the geometric centers of five lumbar vertebrae bodies and the most dorsal points of five corresponding spinous processes, as well as the anterior sacral promontory (Fig 1a and 1b). The acetabular rim plane was obtained by fitting a set of point along the acetabular rim to a plane using least squares method. The acetabular orientation was defined as the three coordinate components (x-, y- and z- components) of the unit normal vector of the acetabular rim plane in the two coordinate systems (Fig. 1c).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 146 - 146
1 Feb 2017
McEntire B Jones E Bock R Ray D Bal B Pezzotti G
Full Access

Introduction

Periprosthetic infections are leading causes of revision surgery resulting in significant increased patient comorbidities and costs. Considerable research has targeted development of biomaterials that may eliminate implant-related infections.1 This in vitro study was developed to compare biofilm formation on three materials used in spinal fusion surgery – silicon nitride, PEEK, and titanium – using one gram-positive and one gram-negative bacterial species.

Materials and Methods

Several surface treated silicon nitride (Si3N4, MC2®, Amedica Corporation, Salt Lake City, UT), poly-ether-ether-ketone (PEEK, ASTM D6262), and medical grade titanium (Ti6Al4V, ASTM F136) discs Ø12.7 × 1mm were prepared or acquired for use in this well-plate study. Each group of discs (n=3) were ultrasonically cleaned, UV-sterilized, inoculated with 105Staphylococcus epidermidis (ATCC® 25922™) or Escherichia coli (ATCC® 14990™) and placed in a culture medium of phosphate buffered saline (PBS) containing 7% glucose and 10% human plasma on a shaking incubator at 37°C and 120 rpm for 24 or 48 hrs. Coupons were retrieved, rinsed in PBS to remove planktonic bacteria, placed in a centrifuge with fresh PBS, and vortexed. The bacterial solutions were serially diluted, plated, and incubated at 37°C for 24 to 48 hrs. Colony forming units (CFU/mm2) were counted using applicable dilution factors and surface areas. A two-tailed, heteroscedastic Student's t-test (95% confidence) was used to determine statistical significance.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 31 - 31
1 Feb 2017
Jahani F Fisher J Barton D Brooks J Wilcox R Jones A
Full Access

Introduction

The performance of total hip replacement (THR) devices can be affected by the quality of the tissues surrounding the joint or the mismatch of the component centres during hip replacement surgery. Experimental studies have shown that these factors can cause the separation of the two components during walking cycle (dynamic separation) and the contact of the femoral head with the rim of the acetabular liner (edge loading), which can lead to increased wear and shortened implant lifespan1. There is a need for flexible pre-clinical testing tools which allow THR devices to be assessed under these adverse conditions. In this work, a novel dynamic finite element model was developed that is able to generate dynamic separation as it occurs during the gait cycle. In addition, the ability to interrogate contact mechanics and material strain under separation conditions provides a unique means of assessing the severity of edge loading. This study demonstrates these model capabilities for a range of simulated surgical translational mismatch values, for ceramic-on-polyethylene implants.

Methodology

The components of the THR were aligned and constrained as illustrated in Figure 1. CAD models of commercially available implant geometries were used (DePuy Synthes, Leeds, UK) modified for model simplicity by removing anti-rotation features.

The polyethylene cup liner was given elastic-plastic behaviour. An axial load following the Paul cycle pattern (5 repetitive cycles) with maximum of 3KN and swing phase load of 0.3KN, was applied through the cup holder. The effect of translational mismatch was implemented by using a spring element connected to the cup unit on the lateral side. The spring was compressed by a fixed amount to replicate a degree of medial-lateral mismatch of the components. The instantaneous resultant force vector dictated the dynamic sliding behaviour of the cup against the head. In this study, translational medial-lateral mismatch values of 1, 2, 3 and 4mm were used and the medial-lateral dynamic separation, contact pressure maps and plastic strain were recorded.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 143 - 143
1 Feb 2017
Greene A Hamilton M Polakovic S Andrews R Jones R Parsons I Saadi P Cheung E Flurin P Wright T
Full Access

INTRODUCTION

As computer navigated surgery continues to progress to the forefront of orthopedic care, the application of a navigated total shoulder arthroplasty has yet to appear. However, the accuracy of these systems is debated, as well as the dilemma of placing an accurate tool in an inaccurate hand. Often times a system's accuracy is claimed or validated based on postoperative imaging, but the true positioning is difficult to verify. In this study, a navigation system was used to preoperatively plan, guide, and implant surrogate shoulder glenoid implants and fiducials in nine cadaveric shoulders. A novel method to validate the position of these implants and accuracy of the system was performed using pre and post operative high resolution CT scans, in conjunction with barium sulfate impregnated PEEK surrogate implants.

METHODS

Nine cadaveric shoulders were CT scanned with .5mm slice thickness, and the digital models were incorporated into a preoperative planning software. Five orthopedic shoulder specialists used this software to virtually place aTSA and rTSA glenoid components in two cadavers each (one cadaver was omitted due to incomplete implantation), positioning the components as they best deemed fit. Using a navigation system, each surgeon registered the native cadaveric bone to each respective CT. Each surgeon then used the navigation system to guide him or her through the total shoulder replacement, and implant the barium sulfate impregnated PEEK surrogate implants. Four cylindrical PEEK fiducials were also implanted in each scapula to help triangulate the position of the surrogate implants. Previous efforts were attempted with stainless steel alloy fiducials, but position and image accuracy were limited by CT artifact. BaSO4 PEEK provided the highest resolution on a postoperative CT with as little artifact as possible. All PEEK fiducials and surrogate implants were registered by probing points and planes with the navigation system to capture the digital position. A high resolution post operative CT scan of each specimen was obtained, and variance between the executed surgical plan and PEEK fiducials was calculated.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 36 - 36
1 Feb 2017
Jones H Gonzalez J Doherty D Noble P
Full Access

Introduction

As the population continues to grow and age, the incidence of revision total knee replacement (RTKR) is expected to rise significantly. Modularity within revision total knee systems is common, and recognition of modular junctions as an important source adverse local tissue reaction (ALTR) has not yet been fully described in the literature. In both hips and knees, ALTR may be caused by wear debris from articulating surfaces, stress shielding, and other classic areas of focus, but now attention is shifting towards the role of corrosion products from modular junctions. In severe cases, junctions can become welded together creating significant hurdles in revisions and potentially altered biomechanics in vivo. In view of these issues, the present study was undertaken: (i) to examine the level of damage observed in modular junctions of total knee prostheses obtained at revision, (ii) to correlate the severity of surface damage to the design and composition of the mating components, and (iii) to associate patient demographics and comorbidities with the spectrum of corrosion and fretting seen in retrieved implants.

Methods

117 TKR components from 76 patients were examined after retrieval from revision procedures performed at a single institution. Patient demographics and clinical data were compiled. The retrievals consisted of 57 femoral components and 60 tibial components from a diverse range of manufacturers. The implants were disassembled manually, or in a mechanical testing machine if cold welded, and separated into groups based on mating material type. Modular junctions were then examined using stereomicroscopy (Wild) at magnifications of X6 to X31. Upon inspection, damage on the male component was graded using modified Goldberg scales for corrosion and fretting (Table 1). Factors associated with trunnions having damage scores of 3 or higher were evaluated using standard statistical procedures to determine the susceptibility for corrosion of each junction type and location.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 37 - 37
1 Feb 2017
Jones H Chun A Kim R Gonzalez J Noble P
Full Access

Introduction

Corrosion products from modular taper junctions of hip prostheses have been implicated in adverse local tissue reactions after THR. Numerous factors have been proposed as the root causes of this phenomenon, including implant design and materials, manufacturing variables, intraoperative assembly, and patient lifestyle. As significant taper damage only occurs in a few percent of cases of THR, we have addressed this complication using a “forensic” examination of retrieval specimens to gain insight into the factors initiating the cascade leading to irreversible damage of the modular interface. In this study we report the categorization of over 380 retrievals into groups having shared damage patterns, metallic composition, and interface surface geometries to isolate the genesis of mechanically-assisted corrosion and its relation to intraoperative assembly, manufacturing, and postoperative loading.

Methods

A total of 384 femoral components were examined after retrieval at revision THR. The implants were produced by a diverse range of manufacturers, 271 in CoCr, and 113 in TiAlV, with both smooth (253) and machined (131) tapers. Initially, the implants were sorted into groups based on composition and taper roughness. Each trunnion was then cleaned to remove organic deposits and examined by stereomicroscopy at X6-X31. After an initial pilot study, we developed a classification system consisting of 8 basic patterns of damage (Table 1). We then classified all 384 trunnions according to this 8-group system. The prevalence of each pattern was calculated on the basis of both composition and surface texture of the trunnion.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 22 - 22
1 Feb 2017
Huixiang W Newman S Jones G Sugand K Cobb J Auvinet E
Full Access

Introduction

Because of the low cost and easy access, surgical video has become a popular method of acquiring surgical skills outside operating rooms without disrupting normal surgical flow. However, currently existing video systems all use a single point of view (POV). Some complex orthopedic procedures, such as joint replacement, require a level of accuracy in several dimensions. So single and fixed POV video may not be enough to provide all the necessary information for educational and training purposes. The aim of our project was to develop a novel multiple POV video system and evaluate its efficacy as an aid for learning joint replacement procedure compared with traditional method.

Materials and Methods

Based on the videos of a hip resurfacing procedure performed by an expert orthopedic surgeon captured by 8 cameras fixed all around the operating table, we developed a novel multiple POV video system which enables users to autonomously switch between optimal viewpoints (Figure 1). 30 student doctors (undergraduate years 3–5 and naive to hip resurfacing procedure) were recruited and randomly allocated to 2 groups: experiment group and control group, and were assigned to learn the procedure using multiple or single POV video systems respectively. Before learning they were first asked to complete a multiple choicetest designed using a modified Delphi technique with the advice and feedback sought from 4 experienced orthopedic surgeons to test the participants' baseline knowledge of hip resurfacing procedure. After video learning, they were asked to answer the test again to verify their gained information and comprehension of the procedure, followed by a 5-point Likert-scale questionnaire to demonstrate their self-perception of confidence and satisfaction with the learning experience. The scores in the 2 tests and in the Likert-scale questionnaire were compared between 2 groups using Independent-Samples t-test (for normally distributed data) or Mann-Whitney U test (for non-normally distributed data). Statistical significance was set as p<0.05.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 104 - 104
1 Feb 2017
Noble P Dua R Jones H Garrett K
Full Access

Background

Recent advances in materials and manufacturing processes for arthroplasty have allowed fabrication of intricate implant surfaces to facilitate bony attachment. However, refinement and evaluation of these new design strategies is hindered by the cost and complications of animal studies, particularly during early iterations in development process. To address this problem, we have constructed and validated an ex-vivo bone bioreactor culture system to enable empirical testing of candidate structures and materials. In this study, we investigated mineralization of a titanium wire mesh scaffold under both static and dynamic culturing using our ex vivo bioreactor system.

Methods

Cancellous cylindrical bone cores were harvested from bovine metatarsals and divided into five groups under different conditions. After incubation for 4 & 7 weeks, the viability of each bone sample was evaluated using Live-Dead assay and microscopic anatomy of cells were determined using histology stain H&E. Matrix deposits on the scaffolds were examined with scanning electron microscopy (SEM) while its chemical composition was measured using energy-dispersive x–ray spectroscopy (EDX).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 85 - 85
1 Dec 2016
Jones R
Full Access

Obtaining primary wound healing in total joint arthroplasty (TJA) is essential to a good result. Wound healing disturbances (WHD) can occur and the consequences can be devastating to the patient and to the surgeon. Determination of the host healing capacity can be useful in predicting complications. Cierney and Mader classified patients as Type A: no healing compromises and Type B: systemic or local healing compromise factors present. Local factors include traumatic arthritis with multiple previous incisions, extensive scarring, lymphodema, poor vascular perfusion, and excessive local adipose deposition. Systemic compromising factors include diabetes, rheumatic diseases, renal or liver disease, immunocompromise, steroids, smoking, and poor nutrition. Low serum albumin, total lymphocyte count, and low transferrin increase WHD. In high risk situations the surgeon should encourage positive patient choices such as smoking cessation and nutritional supplementation to modify healing responses. Use of tourniquet in obese patients also increases WHD.

Careful planning of incisions, particularly in patients with scarring or multiple previous operations, is productive. Around the knee the vascular viability is better in the medial flap. Thusly, use the most lateral previous incision, do minimal undermining, and handle tissue meticulously. We do all potentially complicated TKA's without tourniquet to enhance blood flow and tissue viability. The use of perioperative anticoagulation will increase wound problems.

If wound drainage or healing problems do occur, immediate action is required. Deep sepsis can be ruled out with a joint aspiration and cell count (less than 2500), differential (less than 60% polys), and negative culture and sensitivity. All hematomas should be evacuated and necrosis or dehiscence should be managed by debridement to obtain a live wound.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 98 - 98
1 Dec 2016
Jones R
Full Access

The major benefit of TKA with tourniquet is operating in a bloodless field. A possible secondary benefit is a better cement-bone interface for fixation.

The disadvantages of tourniquet use for TKA include multiple risk factors both local and systemic: Nerve damage, Altered hemodynamics with limb exsanguinations (15–20% increase in circulatory volume) and reactive hyperemia with tourniquet release (10% increase in limb size increasing soft tissue tension and secondary pain), Delay in recovery of muscle function, Increased risk of DVT with direct trauma to vessel walls and increased levels of thrombin-antithrombin complexes, A 5.3x greater risk for large venous emboli propagation and transesophageal echogenic particles, Vascular injury with higher risk in atherosclerotic, calcified arteries, Increase in wound healing disturbances, Obese patients TKA with tourniquet show impaired endothelial function and more DVTs.

Our initial experience with TKA without tourniquet was in high risk patients with previous DVT or PE, multiple scarring, or compromised cardiovascular status. We have used this method on all patients for the last 14 years. The protocol includes regional anesthesia, incision and approach made with 90-degree knee flexion, meticulous hemostasis, jet lavage and filtered carbon dioxide delivered to dry and prepare bone beds for cementation, application of topical tranexamic acid and routine closure. We have encountered no differences in blood loss or transfusion rates, cement penetration/ fixation, less postoperative pain, faster straight leg raise and knee flexion gains, and fewer wound healing disturbances. We recommend TKA sans tourniquet. Let it bleed!


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 33 - 33
1 Nov 2016
Jones R
Full Access

In the USA, 34.9% of adults are currently obese (BMI > 30). Growth in total knee arthroplasty (TKA) is outpacing growth in total hip arthroplasty (THA) largely due to a differential utilization of TKA in overweight patients in the USA. In a recent study, 54.5% of patients reporting to arthroplasty clinics in the USA were obese. From 2006–2010, 61.2% of primary unilateral TKA patients in the USA ACS-NSQIP database were obese. Arthroplasty surgeons are directly affected by the obesity epidemic and need to understand how to safely offer a range of peri-operative care for these patients in order to insure good clinical outcomes.

Pre-operative care for the obese patient involves nutritional counseling, weight loss methods, consideration for bariatric surgery, physical therapy, metabolic workup, and diagnosis and management of frequent comorbid conditions (OSA, DM2, HTN, HLD). Obese patients must also be counseled on their increased risk of complications following TKA.

In the operating room, several steps can be taken to insure success when performing TKA on obese patients. We recommend performing TKA without the use of a tourniquet in order to prevent fat necrosis and increased pain. The incision is made in 90 degrees of knee flexion, atypically midline proximally and curved distally to the midpoint between the tubercle and the medial edge of the tibia. Care is used to minimise the creation of dead space, and the approach to the knee is an extensile medial parapatellar incision. Closure is in multiple layers. The use of negative pressure dressing following surgery can minimise the early wound drainage that is frequently seen after TKA in obese patients.

Post-operative care of the obese patient following TKA involves several unique considerations. Chronic pain and obesity are frequent comorbid conditions and post-operative pain control regimens need to be tailored. Although the physical therapy regimen does not differ in obese patients, obese patients are more likely to be discharged to a rehabilitation facility.

Obese patients have a higher rate of all complications compared to healthy weight. All infection and deep infection increased in obese patients in large meta-analysis. Patients with BMI > 35 are 6.7 times more likely to develop infection after TKA. Patients with BMI > 40 have a 3.35 times higher rate of revision for deep infection than those with BMI < 35. The odds ratio for major complications increases dramatically beyond BMI > 45.

Although there are a few studies that have demonstrated worse clinical outcome in obese patients following TKA, most studies show no difference in clinical outcomes at short- or long-term follow-up. The arthroplasty surgeon must optimise the obese patient prior to surgery, use intra-operative techniques to maximise success, and anticipate potential problems in the post-operative course in order to achieve success with TKA in obese patients.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 63 - 63
1 Nov 2016
Jones R
Full Access

Persistent post-surgical pain (PPSP) remains a problem after knee replacement with some studies reporting up to 20% incidence. Pain is usually felt by those who do not operate to be a monolithic entity. All orthopaedic surgeons know that this is not the case. At its most basic level, pain can be divided into two categories, mechanical and non-mechanical.

Mechanical pain is like the pain of a fresh fracture. If the patient does not move, the pain is less. This type of pain is relieved by opiates. Mechanical pain is seen following knee replacement, but is becoming less frequent. It is caused by a combination of malrotations and maltranslations, often minor, which on their own would not produce problems. The combination of them, however, may produce a knee in which there is overload of the extensor mechanism or of the medial stabilizing structures. If these minor mechanical problems can be identified, then corrective surgery will help.

Non-mechanical pain is present on a constant basis. It is not significantly worsened by activities. Opiates may make the patient feel better, but they do not change the essential nature of the pain. Non-mechanical pain falls into three broad groups, infection, neuropathic and perceived pain. Infection pain is usually relieved by opiates. Since some of this pain is probably due to pressure, its inclusion in the non-mechanical pain group is questionable, but it is better left there so that the surgeon always considers it. Low grade chronic infection can be extremely difficult to diagnose. Loosening of noncemented knee components is so rare that when it is noted radiologically, infection should be very high on the list of suspicions. The name neuropathic pain suggests that we know much more about it than we do in reality. Causalgia or CRPS-type two is rare following knee replacement. CRPS-type one or reflex sympathetic dystrophy probably does exist, but it is probably over-diagnosed. The optimum treatment I have found is lumbar sympathetic blocks. Lyrica, Gabapentin and Cymbalta may also help. Perceived pain is the largest group. It does not matter what you tell the patient, some believe a new knee should be like a new car, i.e. you step into it and drive away. The fact that they have to work to make it work is horrifying. Perceived pain is widespread. The classic treatise, Dr. Ian McNabb's book “Backache”, should be studied by all who wish to understand pain complaints.

Any experienced knee surgeon will have his list of red flags or caveats. I will list only a few. If the patient comes in with a form asking for a disability pension on the first visit. If the patient's mother answers the questions. If the patient comes in taking massive doses of opiates. If the patient is referred to you by a surgeon who does more knee replacements than you do.

There are other issues such as good old fibromyalgia, which appears to have gone the way of the dodo. It has been replaced by something equally silly called central sensitization. The theory of central sensitization is that if one has pain somewhere or other for three months or six months or whatever, there are going to be changes in the brain and spinal cord. It then does not matter what happens to the original pain, i.e. whether or not it goes away, the pain will persist because of the changes in the brain, hence, the title of the pain in the brain syndrome. If this theory was correct, we might as well all go home because we have all been wasting our time for the last 30 years because none of our patients would get any better. After all, all of our patients have had pain for a lot longer than three months, many of them have been involved in trauma and sometimes, compensation is at issue. The pain in the brain theory, therefore, sounds about as realistic as the flat earth society or the treatment of Galileo.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 42 - 42
1 Nov 2016
Jones R
Full Access

Functional restoration of patella kinematics is an essential component of TKA, whether the patella is replaced or not. This goal is accomplished by a multifactorial approach: establish proper component position and alignment, especially rotation, avoid IR of the femoral and ER of the tibial components, maintain correct joint line position, achieve symmetrical soft tissue balance

Most modern TKA designs have an anatomic trochlear groove shape to enable midline tracking. Patella implants are better designed as well with three equilateral lugs for fixation and either dome or anatomic shape. The apex of the patella component should be aligned with the apex of the patella raphe which is more medial than lateral. This method leaves an island of exposed lateral patella facet which is managed with the “lateral slat technique” to be described. It is essentially an intraosseous lateral release. The early mobilization of modern TKA patients demands watertight closure to prevent soft tissue attenuation and late tracking issues.

When confronted with a patient with a laterally dislocated patella, implementation of the “lateral slat technique” should be done at the approach to obtain midline tracking. Such patients require a median parapatellar (MPP) approach and may need distal-lateral vastus medialis advancement (Insall procedure).

Adherence to the principles iterated herein will produce a happy patient with good patello-femoral kinematics and function.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 100 - 100
1 Nov 2016
Petis S Vasarhelyi E Lanting B Jones I Birmingham T Howard J
Full Access

Total hip arthroplasty (THA) is the most effective treatment modality for severe arthritis of the hip. Patients report excellent clinical and functional outcomes following THA, including subjective improvement in gait mechanics. However, few studies in the literature have outlined the impact of surgical approach on gait kinetics and kinematics. The purpose of this study was to determine the impact of surgical approach for THA on quantitative gait analysis.

Thirty patients undergoing THA for primary osteoarthritis of the hip were assigned to one of three surgical approaches (10 anterior, 10 posterior, and 10 lateral). A single surgeon performed each individual approach. Each patient received standardised implants at the time of surgery (cementless stem and acetabular component, cobalt chrome femoral head, highly cross-linked liner). Patients underwent 3D gait analysis pre-operatively, and at 6- and 12-weeks following the procedure. At each time point, temporal gait parameters, kinetics, and kinematics were compared. Statistical analysis was performed using one-way analysis of variance.

All three groups were similar with respect to age (p=0.27), body mass index (p=0.16), and the Charlson Comorbidity Index (p=0.66). Temporal parameters including step length, stride length, gait velocity, and percent stance and swing phase were similar between the groups at all time points. The lateral cohort had higher pelvic tilt during stance on the affected leg than the anterior cohort at 6-weeks (p=0.033). Affected leg ipsilateral trunk lean during stance was higher in the lateral group at 6-weeks (p=0.006) and 12-weeks (p=0.037) compared to the other cohorts. The anterior and posterior groups demonstrated an increased external rotation moment at 6-weeks (p=0.001) and 12-weeks (p=0.005) compared to the lateral group.

Although temporal parameters were similar across all groups, some differences in gait kinematics and kinetics exist following THA using different surgical approaches. However, the clinical relevance based on the small magnitude of the differences remains in question.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 16 - 16
1 Jul 2016
Aujla R Patel S Aziz S Jones A Bhatia M
Full Access

Acute Achilles tendon (AT) rupture management remains debatable but non-operative functional regimes are beginning to dominate current treatment algorithms. The aim of this study was to identify predictors of functional outcome in patients with AT ruptures treated non-operatively with an immediate weight bearing functional regime in an orthosis.

Analysis of prospectively gathered data from a local database of all patients treated non-operativelyat our institution with anAT rupture was performed. Inclusion criteria required a completed Achilles Tendon Rupture Score (ATRS) at a minimum of 8 months post rupture. The ATRS score was correlated against age, gender, time following rupture, duration of treatment in a functional orthoses (8- and 11-week regimes) and complications. 236 patients of average age 49.5 years were included.

The mean ATRS on completion of rehabilitation was 74 points. The mean ATRS was significantly lower in the 37 females as compared to the 199 males, 65.8 vs 75.6 (p = 0.013). Age inversely affected ATRS with a Pearsons correlation of −0.2. There was no significant difference in the ATRS score when comparing the two different treatment regime durations. There were 12 episodes of VTE and 4 episodes of re-rupture. The ATRS does not change significantly after 8 months of rupture.

Patients with AT ruptures treated non-operatively with a functional rehabilitation regime demonstrate good function with low re-rupture rates. Increasing age and female gender demonstrate inferior functional outcomes.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 7 - 7
1 Jul 2016
Lokikere N Saraogi A Sonar U Porter M Kay P Wynn-Jones H Shah N
Full Access

Distal femoral replacement is an operation long considered as salvage operation for neoplastic conditions. Outcomes of this procedure for difficult knee revisions with bone loss of distal femur have been sparsely reported.

We present the early results of complex revision knee arthroplasty using distal femoral replacement implant, performed for severe osteolysis and bone loss.

Retrospective review of clinic and radiological results of 25 consecutive patients operated at single centre between January 2010 and December 2014. All patients had single type of implant. All data was collected till the latest follow up. Re-revision for any reason was considered as primary end point.

Mean age at surgery was 72.2 years (range 51 – 85 years). Average number of previous knee replacements was 2.28 (range 1 to 6). Most common indications were infection, aseptic loosening and peri-prosthetic fracture. Average follow up was 24.5 months (range: 3–63 months). 1 patient died 8 months post-op due to unrelated reasons. Re-revision rate was 2/25 (8%) during this period. One was re-revised for aseptic loosening and one was revised for peri-prosthetic fracture of femur. Two other peri-prosthetic fractures were managed by open reduction and internal fixation. All 3 peri-prosthetic fractures occurred with low energy trauma.

It is noteworthy that there was no hinge or mechanical failures of the implant. Peri-prosthetic fracture in 12% of patients in this series is of concern. There are no similar studies to compare this data with. The length of the stem, type of fixation of the stem, weight of the distal femoral component of implant can be postulated as factors contributing to risk of peri-prosthetic fracture.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_13 | Pages 3 - 3
1 Jun 2016
Lokikere N Jakaraddi C Wynn-Jones H Shah N
Full Access

Primary total hip replacement (THR) in patients with abnormal/altered proximal femoral anatomy/narrow canals presents a technical challenge. There are only limited standard prosthetic stems available to deal with narrow canals or abnormal morphology. Many prefer to use expensive custom implants which often have a lag time to manufacture and do not always have long term published outcomes.

We present results of the Asian C-stem (which is a standard implant available on the shelf) used in patients predominantly of Caucasian origin with abnormal proximal femoral anatomy.

We retrospectively reviewed clinic-radiological results of 131 patients (131 stems) who underwent primary THR using Asian C-stem at Wrightington Hospital till their latest follow up. Revision for any reason was considered as primary end point.

Mean age at surgery was 50.8 years (16 – 80). The 2 commonest indications were primary osteoarthritis (66 patients) and hip dysplasia (54 patients). Mean follow up was 43.5 months with a minimum follow up of 12 months and maximum follow up of 97 months. There were 2 recurrent dislocations and 1 hip subluxed twice. One dislocation needed revision surgery. 1 patient underwent acetabular revision for loosening. There was no stem failure, obvious loosening or loss of fixation in any patients in our series with regards to the Asian C-stem. There were no infections and intra-operative perforations or fractures.

C-stem Asian is a reliable implant for patients undergoing THR with abnormal proximal femoral anatomy or narrow canals. Long term follow up is essential.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 68 - 68
1 May 2016
Jones G Clarke S Jaere M Cobb J
Full Access

The treatment of patients with osteoarthritis of the knee and associated extra-articular deformity of the leg is challenging. Current teaching recognises two possible approaches: (1) a total knee replacement (TKR) with intra-articular bone resections to correct the malalignment or (2) an extra-articular osteotomy to correct the malalignment together with a TKR (either simultaneously or staged).

However, a number of these patients only have unicompartmental knee osteoarthritis and, in the absence of an extra-articular deformity would be ideal candidates for joint preserving surgery such as unicompartmental knee replacement (UKR) given its superior functional outcome and lower cost relative to a TKR [1).

We report four cases of medial unicondylar knee replacement, with a simultaneous extra-articular osteotomy to correct deformity, using novel 3D printed patient-specific guides (Embody, UK) (see Figure 1). The procedure was successful in all four patients, and there were no complications. A mean increase in the Oxford knee score of 9.5, and in the EQ5D VAS of 15 was observed.

To our knowledge this is the first report of combined osteotomy and unicompartmental knee replacement for the treatment of extra-articular deformity and knee osteoarthritis. This technically challenging procedure is made possible by a novel 3D printed patient-specific guide which controls osteotomy position, degree of deformity correction (multi-plane if required), and orientates the saw-cuts for the unicompartmental prosthesis according to the corrected leg alignment.

Using 3D printed surgical guides to perform operations not previously possible represents a paradigm shift in knee surgery. We suggest that this joint preserving approach should be considered the preferred treatment option for suitable patients.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 90 - 90
1 May 2016
Cobb J Collins R Brevadt M Auvinet E Manning V Jones G
Full Access

Normal human locomotion entails a rather narrow base of support (BoS), of around 12cm at normal walking speeds. This relatively narrow gait requires good balance, and is beneficial, as it minimises the adduction moment at the knee. Normal knees have a slightly oblique joint line, and slight varus, which allow the normal human to walk rapidly with a narrow BoS. Patients with increased varus and secondary osteoarthritis have a broader BoS, which exacerbates the excessive load, making walking painful and ungainly.

We wondered if there would be a difference between the base of support of patients whose knee kinematics had been preserved, by retaining the native jointline obliquity and the acl, in comparison with those whose alignment had been altered to a mechanically correct ‘neutral’ alignment.

Materials and Methods

Of 201 patients measured following knee arthroplasty, 31 unicondylar patients and 35 total knee patients, with a single primary arthroplasty, and no co-morbidities, over 1 year post-operatively were identified. Two control groups of controls, a younger cohort of 112 people and 17 in an age matched older cohort.

All operations were performed by the same surgeon. The total knees were cruciate retaining devices, inserted in mechanical alignment, and the unicondylar knees were inserted retaining the native alignment and joint-line obliquity.

The gait of all subjects was analysed on an instrumented, calibrated treadmill with underlying force plates. Patients start by walking at a comfortable speed for them for 5 minutes, before the speed of the treadmill is increased at 1/2 km/h increments until maximum walking speed obtained, spending 30 seconds at each. After the flat test, it was then repeated on a downhill slope of 6°.

Base of Support is interpreted as the distance between the centre point of heel strike and toe off from one foot to that of the other.

The top walking speed in the unicondylar group was significantly greater than that of the total knee group, as we reported in 2013.

TKA patients have an average BoS of 14cm, while UKA patients and controls have a 12cm BoS. The BoS did not reduce with speed. This 2cm, or 17% increase in BoS is significant. Shapiro-Wilk tests demonstrate a normal distribution to the results, and ANOVA testing reveals a significant difference (p<0.05) within the groups between the speeds of 4.5 to 9. Post-Hoc Bonferroni testing reveal a significant difference between the TKA group and each of the other three groups.

On the downhill test (figure 1), the mean BoS in the TKA group increased to 16cm. This increase is highly significant, with a p value of <0.001, while the increase in the UKA group at higher speeds failed to reach significance, and the controls both stayed at 12cm. 6 Bi-uni knees tested acted just like the UKAs.

Discussion

A narrow base of support minimises excessive loads across the joint line. Maintenance of jointline obliquity and an ACL enables this feature to be returned to normal following uni, or bi-uni, while a well aligned TKA seems to prevent it.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 85 - 85
1 May 2016
Asada S Ouyang Y Jones H Ismaily S Noble P
Full Access

Introduction

Restoration of knee function after total knee arthroplasty (TKA) often entails a balance between normal kinematics and normal knee stability, especially in performing demanding physical activities. The ultra-congruent (UC) knee design prioritizes stability over kinematics through close conformity between the femoral component and the tibial insert in extension. This configuration is intended to provide AP stability in the absence of the posterior cruciate ligament during activities that would otherwise cause anterior femoral subluxation. In this study we examine the kinematics of an ultra-congruent knee design in comparison with the intact knee and with conventional articulations used in PCL-retaining (CR) and PCL-substituting (PS) TKR designs.

Materials and Methods

The 3D tibio-femoral kinematics of 6 fresh frozen cadaveric human knees were tested during loaded simulation of squatting in a computer-controlled knee testing rig. Muscle forces were simulated by loading rectus femoris and vastus intermedius (150N), vastus lateralis (100N), vastus medialis (75N), and the hamstring muscles (60N) (total: 385N). Testing was performed on the intact knee, and after implanting a standard design of total knee prosthesis with the posterior cruciate ligament intact (CR-TKA), resected (PCL-substituting insert; PS-TKA), and a UC insert (UC-TKA group). The 3D positions of the tibia and femur were tracked with a high resolution 12 camera motion analysis system (Motion Analysis Inc.) and used to position 3D CT reconstructions of each bone. The translation and rotation of the femur with respect to the tibia were calculated by projecting the femoral transcondylar axis onto a plane normal to the longitudinal anatomical axis of the tibia coincident with the transverse axis of the tibial plateau.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 67 - 67
1 May 2016
Jones G Jaere M Clarke S Cobb J
Full Access

Introduction

Opening wedge high tibial osteotomy is an attractive surgical option for physically active patients with early osteoarthritis and varus malalignment. Unfortunately use of this surgical technique is frequently accompanied by an unintended increase in the posterior tibial slope, resulting in anterior tibial translation, and consequent altered knee kinematics and cartilage loading(1).

To address this unintended consequence, it has been recommended that the relative opening of the anteromedial and posterolateral corners of the osteotomy are calculated pre-operatively using trigonometry (1). This calculation assumes that the saw-cut is made parallel to the native posterior slope; yet given the current reliance on 2D images and the ‘surgeon's eye’ to guide the saw-cut, this assumption is questionable.

The aim of this study was to explore how accurately the native posterior tibial slope is reproduced with a traditional freehand osteotomy saw-cut, and whether novel 3D printed patient-specific guides improve this accuracy.

Methods

26 fourth year medical students with no prior experience of performing an osteotomy were asked to perform two osteotomy saw-cuts in foam cortical shell tibiae; one freehand, and one with a 3D printed surgical guide (Embody, London) that was designed using a CT scan of the bone model. The students were instructed to aim for parallelity with a hinge pin which had been inserted (with the use of a highly conforming 3D printed guide) parallel to the posterior slope of the native joint.

For the purpose of analysis, the sawbones were consistently orientated along their mechanical and anatomical tibial axes using custom moulded supports. Digital photographs taken in the plane of the osteotomy were analysed with ImageJ software to calculate the angular difference in the sagittal plane between the hinge-pin and saw-cut. Statistical analysis was performed with SPSS v21 (Chicago, Illinois); a paired t-test was used to compare the freehand and patient-specific guide techniques. Statistical significance was set at a p-value <0.05.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 92 - 92
1 May 2016
Lancaster-Jones O Al-Hajjar M Williams S Jennings L Thompson J Isaac G Fisher J
Full Access

Introduction and Aims

In order to improve the longevity and design of an implant, a wide range of pre-clinical testing conditions should be considered including variations in surgical delivery, and patients' anatomy and biomechanics. The aim of this research study was to determine the effect of the acetabular cup inclination angle with different levels of joint centre mismatch on the magnitude of dynamic microseparation, occurrence and severity of edge loading and the resultant wear rates in a hip joint simulator.

Methods

The six-station Leeds Mark II Anatomical Physiological Hip Joint Simulator and 36mm diameter ceramic-on-ceramic bearings (BIOLOX® delta) were used in this study. A standard gait cycle, with a twin-peak loading (2.5kN peak load and approximately 70N swing phase load), extension/flexion 15°/+30° and internal/external ±10° rotations, was applied. Translational mismatch in the medial-lateral axis between the centres of rotation of the head and the cup were considered. In this study, mismatches of 2, 3 and 4 (mm) were applied. Two acetabular cup inclination angles were investigated; equivalent to 45° and 65° in-vivo. These resulted in a total of six conditions [Figure 1] with n=6 for each condition. Three million cycles were completed under each condition. The lubricant used was 25% (v/v) new-born calf serum supplemented with 0.03% (w/v) sodium azide to retard bacterial growth. The wear of the ceramic bearings were determined using a microbalance (XP205, Mettler Toledo, UK) and a coordinate measuring machine (Legex 322, Mitutoyo, UK). The stripe wear was analysed using RedLux software. The dynamic microseparation displacement was measured using a linear variable differential transformer. Mean wear rates and 95% confidence limits were determined and statistical analysis (one way ANOVA) completed with significance taken at p<0.05. Results Increasing the medial-lateral joint centre mismatch from 2 to 3 to 4mm resulted in an increased dynamic microseparation [Figure 2]. A similar trend was observed for the wear. A higher level of medial-lateral mismatch increased the wear rate under both 45° and 65° cup inclination angle conditions [Figure 3]. The mean wear rates obtained under 65° were significantly higher compared to those obtained under the 45° cup inclination angle conditions for a given medial-lateral mismatch in the joint centre (p=0.02 for 2mm mismatch, p=0.02 for 3 mm mismatch, and p<0.01 for 4mm mismatch).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 9 - 9
1 May 2016
Roche C Flurin P Grey S Wright T Zuckerman J Jones R
Full Access

Introduction

Due to the predictability of outcomes achieved with reverse shoulder arthroplasty (rTSA), rTSA is increasingly being used in patients where glenoid fixation is compromised due to presence of glenoid wear. There are various methods to achieve glenoid fixation in patients with glenoid wear, including the use of bone grafting behind the glenoid baseplate or the use of augmented glenoid baseplates. This clinical study quantifies clinical outcomes achieved using both techniques in patients with severe glenoid wear at 2 years minimum follow-up.

Methods

80 patients (mean age: 71.6yrs) with 2 years minimum follow-up were treated by 7 fellowship trained orthopaedic surgeons using rTSA with bone graft behind the baseplate or rTSA with an augmented glenoid baseplate in patients with severe posterior glenoid wear. 39 rTSA patients (14 female, avg: 73.1 yrs; 25 male, avg: 71.5 yrs) received an augmented glenoid (cohort composed of 24 patients with an 8° posterior augment baseplate and 15 patients with a 10° superior augment baseplate) for treatment of CTA, RCT, and OA with a medially eroded scapula. 41 rTSA patients (27 female, avg: 73.0 yrs; 14 male, avg: 66.9 yrs) received glenoid bone graft (cohort composed of 5 patients with allograft and 36 patients with autograft) for treatment of CTA, RCT, and OA with a medially eroded scapula. Outcomes were scored using SST, UCLA, ASES, Constant, and SPADI metrics; active abduction, forward flexion, and internal/external rotation were also measured to quantify function. Average follow-up was 31.2 months (augment 28.3; graft 34.1). A two-tailed, unpaired t-test identified differences (p<0.05) in pre-operative, post-operative, and pre-to-post improvements.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 49 - 49
1 Feb 2016
d'Entremont AG Jones CE Wilson DR Mulpuri K
Full Access

Perthes disease is a childhood disorder often resulting in femoral head deformity. Categorical/dichotomous outcomes of deformity are typical clinically, however quantitative, continuous measures, such as Sphericity Deviation Score (SDS), are critical for studying interventions. SDS uses radiographs in two planes to quantify femoral head deformity. Limitations of SDS may include non-orthogonal planes and lost details due to projections. We applied this method in 3D, with specific objectives to: 1. Develop SDS-like sphericity measures from 3D data 2. Obtain 2D and 3D sphericity for normal and Perthes hips 3. Compare slice-based (3D) and projection-based (2D) sphericity CT images of 16 normal (8 subjects) and 5 Perthes hips (4 subjects) were segmented to create 3D hip models. Ethics board approval was obtained for this study. SDS consists of roundness error (RE) in two planes and ellipsoid deformation (ED) between planes. We implemented a modified SDS which was applied to (a) orthogonal projections simulating radiographs (sagittal/coronal; 2D-mSDS), and (b) largest radii slices (sagittal/coronal; 3D-mSDS). Mean 2D-mSDS was higher for Perthes (27.2 (SD 11.4)) than normal (11.9 (SD 4.1)). Mean 3D-mSDS showed similar trends, but was higher than 2D (Perthes 33.6 (SD 5.3), normals 17.0 (SD 3.1)). Unlike 2D-mSDS, 3D-mSDS showed no overlap between groups. For Perthes hips, 2D-mSDS was consistent with SDS. For normal hips, 2D-mSDS was higher than expected (similar to Stulberg II). Projection-based (2D) measures may produce lower mSDS due to spatial averaging. Slice-based (3D) measures may better distinguish between normal and Perthes shapes, which may better differentiate effectiveness of treatments.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 89 - 89
1 Jan 2016
Cobb J Collins R Manning V Zannotto M Moore E Jones G
Full Access

The Oxford Hip Score (OHS), the Harris Hip Score (HHS) and WOMAC are examples of patient reported outcome measures (PROMs) have well documented ceiling effects, with many patients clustered close to full marks following arthroplasty. Any arthroplasty that offers superior function would therefore fail to be detectable using these metrics. Two recent well conducted randomised clinical trials made exactly this error, by using OHS and WOMAC to detect a differences in outcome between hip resurfacing and hip arthroplasty despite published data already showing in single arm studies that these two procedures score close to full marks using both PROMS.

We had observed that patients with hip resurfacing arthroplasty (HRA) were able to walk faster and with more normal stride length than patients with well performing hip replacements, but that these objective differences in gait were not captured by PROMs. In an attempt to capture these differences, we developed a patient centred outcome measure (PCOM) using a method developed by Philip Noble's group. This allows patients to select the functions that matter to them personally against which the success of their own operation will be measured.

Our null hypothesis was that this PCOM would be no more successful than the OHS in discriminating between types of hip arthroplasty.

22 patients with a well performing Hip Resurfacing Arthroplasty were identified. These were closely matched by age, sex, BMI, height, preop diagnosis with 22 patients with a well performing conventional THA. Both were compared with healthy controls using the novel PCOM and in a gait lab.

Results

PROMs for the two groups were similar, while HRA scored higher in the PCOM. The 9% difference was significant (p<0.05).

At top walking speed, HRA were 10% faster, with a 9% longer stride length.

Discussion

Outcome measures should be able to detect differences that are clinically relevant to patients and their surgeons. The currently used hip scores are not capable of delivering this distinction, and assume that most hip replacements are effectively perfect. While the function of hip replacements is indeed very good, with satisfaction rates high, objective measures of function are essential for innovators who are trying to deliver improved functional outcome.

The 9% difference in PCOM found in this small study reflects the higher activity levels reported by many, and of similar magnitude to the 10% difference in top walking speed, despite no detectable difference in conventional PROMS. PCOMs may offer further insight into differences in function. For investigators who wish to develop improvements to hip arthroplasty, PCOMs and objective measures of gait may describe differences that matter more to patients than conventional hip scores.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 24 - 24
1 Jan 2016
St Mart J Whittingham-Jones P Davies N Waters T
Full Access

Introduction

Bone loss in the distal femur and proximal tibia is frequently encountered with both complex primary and revision knee replacement surgery. Metaphyseal sleeves provide a good option for enhanced fixation in managing such defects on both the tibia and femur. We present our results in 48 patients (50 knees) with a minimum 12 month follow up (range 12 to 45).

Methods

48 patients (50 knees) who had revision knee arthroplasty for either septic or aseptic loosening. All were graded Type II or III using the Anderson Orthopaedic Research Institute (AORI) grading system of both femoral and tibial defects. A large portion of aseptic loosening revisions were for extreme osteolysis of a bicondylar knee prosthesis.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 69 - 69
1 Dec 2015
Williams R Kotwal R Roberts-Huntley N Khan W Morgan-Jones R
Full Access

At first-stage revision surgery for infection of total knee arthroplasties, antibiotic-impregnated cement spacers are frequently implanted. Two types of cement spacers are commonly used, “static” and “articulating” cement spacers. Advocates of cement spacers state that they deliver high doses of antibiotics locally, increase patient comfort, allow mobility and provide joint stability. They also minimize contracture of collateral ligaments, thereby facilitating re-implantation of a definitive prosthesis at a later stage. The use of these cement spacers, however, are not without significant complications, including patella tendon injuries.

We describe a series of three patients who sustained patella tendon injuries in infected total knee arthroplasties following the use of a static cement spacer at first-stage knee revision.

The patella tendon injuries resulted in significant compromise to wound healing and knee stability requiring multiple surgeries. The mid-term function was poor with an Oxford score at 24 months ranging from 12–20

Based on our experience, we advise caution in the use of static cement spacer blocks. If they are to be used, we recommend that they should be keyed in the bone to prevent patella tendon injuries.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 66 - 66
1 Dec 2015
Khan W Williams R Metah A Morgan-Jones R
Full Access

Honey has been used as a topical antiseptic for at least 5,000 years. SurgiHoney is a CE licensed sterile product, which has been proven to be non-toxic and effective when used topically in the treatment of chronically infected wounds. The key difference from other medical grade honey is the broad spectrum antimicrobial characteristics with activity against Gram +ve, Gram –ve and multi-resistant organisms. Its novel role against the bacterial bioburden and biofilm associated with periprosthetic infections around total knee arthroplasties (TKA's) is therefore considered.

SurgiHoney was used as an implant coating immediately prior to wound closure after implantation of salvage endoprosthesis for multiply revised, infected TKA's undergoing staged reconstruction.

We report a consecutive series of multi-revised, infected revision TKA's where SurgiHoney was used as an active antimicrobial coating. We discuss its intra-operative application and early clinical outcomes.

The use of Surgihoney as a novel anti-microbial is established in the management of complex wound infections. This is the first reported use of SurgiHoney as a deep, implant coating in the salvage of prosthetic joint infection.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 18 - 18
1 Dec 2015
Kendall J Jones S Mcnally M
Full Access

To compare the costs of treatment and income received for treating patients with tibial osteomyelitis, comparing limb salvage with amputation.

We derived direct hospital costs of care for ten consecutive patients treated with limb salvage procedures and five consecutive patients who underwent amputation, for tibial osteomyelitis. We recorded all factors which affect the cost of treatment. Financial data from the Patient-Level Information and Costing System (PLICS) allowed calculation of hospital costs and income received from payment under the UK National Tariff. Hospital payment is based on primary diagnosis, operation code, length of stay, patient co-morbidities and supplements for custom implants or external fixators.

Our primary outcome measure was net income/loss for each in-patient episode.

The mean age of patients undergoing limb salvage was 55 years (range 34–83 years) whereas for amputation this was 61 years (range 51–83 years). Both groups were similar in Cierny and Mader Staging, requirement for soft-tissue reconstruction, anaesthetic technique, diagnostics, drug administration and antibiotic therapy.

In the limb salvage group, there were two infected non-unions requiring Ilizarov method and five free flaps. Mean hospital stay was 15 days (10–27). Mean direct cost of care was €16,718 and mean income was €9,105, resulting in an average net loss of €7,613 per patient. Patients undergoing segmental resection with Ilizarov bifocal reconstruction and those with the longest length of stay generated the greatest net loss.

In the amputation group, there were 3 above knee and 2 below knee amputations for failed previous treatment of osteomyelitis or infected non-union. Mean hospital stay was 13 days (8–17). Mean direct cost of care was €18,441 and mean income was €15,707, resulting in an average net loss of €2,734 per patient. Length of stay was directly proportional to net loss.

The UK National Tariff structure does not provide sufficient funding for treatment of osteomyelitis of the tibia by either reconstruction or amputation. Average income for a patient admitted for limb salvage is €6,602 less than that for amputation even though the surgery is frequently more technically demanding (often requiring complex bone reconstruction and free tissue transfer) and the length of hospital stay is longer.

Although both are significantly loss-making, the net loss for limb salvage is more than double that for amputation. This makes treatment of tibial osteomyelitis in the UK National Health Service unsustainable in the long term.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 64 - 64
1 Dec 2015
Williams R Khan W Huntley N Morgan-Jones R
Full Access

Joint degeneration may make a total knee arthroplasty (TKA) a requirement for pain relief and function. However, the presence of ipsilateral limb osteomyelitis (OM) makes surgical management extremely challenging.

We report the experience of a high volume revision knee surgeon managing ipsilateral limb multi resistant OM and the outcome of subsequent TKA.

Four consecutive patients were identified who had either ipsilateral femoral or tibial chronic osteomyelitis treated prior to undergoing TKA. Surgery to eradicate the osteomyelitis involved a Lautenbach compartmental debridement, and where necessary, healing by secondary intention. The decision to proceed to a TKA was based on history, clinical examination and radiological findings of advanced osteoarthritic change.

The patients had a mean age of 50 years. They had a background of multi-organism OM and underwent single-stage TKAs at an average of 63 months following eradication of the underlying OM.

Three patients did well but had complications associated with poor skin and soft tissues, and abnormal bone anatomy. One patient developed an infection and following a re-revision had an arthrodesis.

The results for the four cases are summarised in Table 1.

We have highlighted that patients with ipsilateral limb multi resistant OM are a difficult cohort to manage.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 51 - 51
1 Dec 2015
Williams R Khan W Williams H Abbas A Mehta A Ayre W Morgan-Jones R
Full Access

A common step to revision surgery for infected total knee replacement (TKR) is a thorough debridement. Whilst surgical and mechanical debridement are established as the gold standard, we investigate a novel adjuvant chemical debridement using an Acetic Acid (AA) soak that seeks to create a hostile environment for organisms, further degradation of biofilm and death of the bacteria.

We report the first orthopaedic in vivo series using AA soak as an intra-operative chemical debridement agent for treating infected TKR's. We also investigate the in vitro efficacy of AA against bacteria isolated from infected TKR's.

A prospective single surgeon consecutive series of patients with infected TKR were treated according to a standard debridement protocol. Patients in the series received sequential debridement of surgical, mechanical and finally chemical debridement with a 10 minute 3% AA soak.

In parallel, we isolated, cultured and identified bacteria from infected TKR's and assessed the in vitro efficacy of AA. Susceptibility testing was performed with AA solutions of different concentrations as well as with a control of a gentamicin sulphate disc. The effect of AA on the pH of tryptone soya was also monitored in an attempt to understand its potential mechanism of action.

Physiological responses during the AA soak were unremarkable. Intraoperatively, there were no tachycardic or arrythmic responses, any increase in respiratory rate or changes in blood pressure. This was also the case when the tourniquet was released. In addition, during the post-operative period no increase in analgesic requirements or wound complications was noted. Wound and soft tissue healing was excellent and there have not been any early recurrent infections at mean of 18 months follow up.

In vitro, zones of inhibition were formed on less than 40% of the organisms, demonstrating that AA was not directly bactericidal against the majority of the clinical isolates. However, when cultured in a bacterial suspension, AA completely inhibited the growth of the isolates at concentrations as low as 0.19%v/v.

This study has shown that the use of 3% AA soak, as part of a debridement protocol, is safe. Whilst the exact mechanism of action of acetic acid is yet to be determined, we have demonstrated that concentrations as low as 0.19%v/v in solution in vitro is sufficient to completely inhibit bacterial growth from infected TKR's.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 61 - 61
1 Nov 2015
Jones R
Full Access

Obtaining primary wound healing in Total Joint Arthroplasty (TJA) is essential to a good result. Wound healing problems can occur and the consequences can be devastating to the patient and to the surgeon. Determination of the host healing capacity can be useful in predicting complications. Cierney and Mader classified patients as Type A: no healing compromises and Type B: systemic or local healing compromises factors present. Local factors include traumatic arthritis with multiple previous incisions, extensive scarring, lymphedema, poor vascular perfusion, and excessive local adipose deposition. Systemic compromising factors include diabetes, rheumatic diseases, renal or liver disease, immunocompromise, steroids, smoking, and poor nutrition. In high risk situations the surgeon should encourage positive patient choices such as smoking cessation and nutritional supplementation to elevate the total lymphocyte count and total albumin.

Careful planning of incisions, particularly in patients with scarring or multiple previous operations, is productive. Around the knee the vascular viability is better in the medial flap. Thusly, use the most lateral previous incision, do minimal undermining, and handle tissue meticulously. We do all potentially complicated TKAs without tourniquet to enhance blood flow and tissue viability. The use of peri-operative anticoagulation will increase wound problems.

If wound drainage or healing problems do occur immediate action is required. Deep sepsis can be ruled out with a joint aspiration and cell count [less than 2500], differential [less than 60% polys], and negative culture and sensitivity. All hematomas should be evacuated and necrosis or dehiscence should be managed by debridement to obtain a live wound.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 42 - 42
1 Nov 2015
Jones R
Full Access

The major benefit of TKA with tourniquet is operating in a bloodless field. A possible secondary benefit is a better cement bone interface for fixation.

The disadvantages of tourniquet use for TKA include multiple risk factors both local and systemic: Nerve damage; Altered hemodynamics with limb exsanguinations (15–20% increase in circulatory volume) and reactive hyperemia with tourniquet release (10% increase in limb size increasing soft tissue tension and secondary pain); Delay in recovery of muscle function; Increased risk of DVT with direct trauma to vessel walls and increased levels of thrombin-antithrombin complexes; A 5.3× greater risk for large venous emboli propagation and transesophageal echogenic particles; Vascular injury with higher risk in atherosclerotic, calcified arteries; Increase in wound healing disturbances.

Our initial experience with TKA without tourniquet was in high risk patients with previous DVT or PE, multiple scarring, or compromised cardiovascular status. We have used this method on all patients for the last eight years. The protocol includes regional anesthesia, incision and approach made with 90-degree knee flexion, meticulous hemostasis, jet lavage and filtered carbon dioxide delivered to dry and prepare bone beds for cementation, application of topical tranexamic acid and routine closure. We have encountered no differences in blood loss or transfusion rates, less post-operative pain, faster straight leg raise and knee flexion gains, and fewer wound healing disturbances. We recommend TKA sans tourniquet. Let it bleed!


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_10 | Pages 29 - 29
1 Oct 2015
Kumar KHS Jones G Forrest N Nathwani D
Full Access

There has been a lot of focus on the value of anatomic tunnel placement in ACL reconstruction, and the relative merits of single and double bundle grafts. Multiple cadaveric and animal studies have compared the effects of tunnel placement and graft type on knee biomechanics. 45 patients who underwent ACL reconstruction were included into our study. Femoral tunnel position was analysed by two independent doctors using the radiographic quadrant method as described by Bernard et al., and the mean values calculated. Forty-one of these patients completed a KOOS questionnaire. The mean ratio ‘a’ was 26.57% and mean ratio ‘b’ was 30.04% as compared to 24.8% (+/− 2.2%) and 28.5% (+/− 2.5%) respectively quoted by Bernard et.al, as the ideal tunnel position. Only twenty-three of these femoral tunnels were in the anatomic range. Analysis of forty-one KOOS surveys (23 anatomic, 18 non-anatomic) revealed no significant difference in total score or subscales between the anatomic and non-anatomic groups (p= >0.05). Our study suggests that the ideal tunnel position, as described by Bernard et.al. may not be ideal and fixed.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 128 - 128
1 Feb 2015
Jones R
Full Access

Functional restoration of patella kinematics is an essential component of TKA, whether the patella is replaced or not. This goal is accomplished by a multifactorial approach: establish proper component position and alignment, especially rotation; avoid IR of the femoral and ER of the tibial components; maintain correct joint line position; achieve symmetrical soft tissue balance.

Most modern TKA designs have an anatomic trochlear groove shape to enable midline tracking. Patella implants are better designed as well with three equilateral lugs for fixation and either dome or anatomic shape. The apex of the patella component should be aligned with the apex of the patella raphe which is more medial than lateral. This method leaves an island of exposed lateral patella facet which is managed with the “lateral slat technique” to be described. It is essentially an intraosseous lateral release. The early mobilization of modern TKA patients demands watertight closure to prevent soft tissue attenuation and late tracking issues.

When confronted with a patient with a laterally dislocated patella, implementation of the “lateral slat technique” should be done at the approach to obtain midline tracking. Such patients require a median parapatellar (MPP) approach and may need distal-lateral vastus medialis advancement (Insall Procedure).

Adherence to the principles iterated herein will produce a happy patient with good patello-femoral kinematics and function.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 71 - 71
1 Feb 2015
Jones R
Full Access

The major benefit of TKA with tourniquet is operating in a bloodless field. A possible secondary benefit is a better cement bone interface for fixation.

The disadvantages of tourniquet use for TKA include multiple risk factors both local and systemic - Nerve damage; Altered hemodynamics with limb exsanguinations (15‐20% increase in circulatory volume) and reactive hyperemia with tourniquet release (10% increase in limb size increasing soft tissue tension and secondary pain); Delay in recovery of muscle function; Increased risk of DVT with direct trauma to vessel walls and increased levels of thrombin-antithrombin complexes; A 5.3x greater risk for large venous emboli propagation and transesophageal echogenic particles; Vascular injury with higher risk in atherosclerotic, calcified arteries; Increase in wound healing disturbances.

Our initial experience with TKA without tourniquet was in high risk patients with previous DVT or PE, multiple scarring, or compromised cardiovascular status. We have used this method on all patients for the last eight years. The protocol includes regional anesthesia, incision and approach made with 90-degree knee flexion, meticulous hemostasis, jet lavage and filtered carbon dioxide delivered to dry and prepare bone beds for cementation, application of topical tranexamic acid and routine closure. We have encountered no differences in blood loss or transfusion rates, less postoperative pain, faster straight leg raise and knee flexion gains, and fewer wound healing disturbances. We recommend TKA sans tourniquet. Let it bleed!


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 13 - 13
1 Dec 2014
Nademi M Naikoti K Salloum W Jones HW Clayson A Shah N
Full Access

Stoppa approach has recently been adapted for pelvic surgery as it allows direct intra-pelvic reduction and fixation of the quadrilateral plate and anterior column. We report our early experience, indications and complications with this exposure introduced in 2010 in our tertiary unit.

A Retrospective review of all Stoppa approaches in pelvic-acetabular fixations was performed from a prospectively maintained database.

Of the 25 patients, mean age 40 years (range 15–76), who underwent pelvic-acetabular fixation using Stoppa approach, 21 patients had mean follow up of 7.3 months (1–48 months). All except 24% of patients had one or more additional systemic injury some requiring additional surgery. There were 6 acetabular fractures, 13 pelvic ring injuries and 6 combined fractures. Mean injury-surgery interval was 9 days (range 3–20). 8 patients had an isolated Stoppa approach whilst the remaining others also had an additional approach. Mean surgical time was 239 minutes. Anatomical reduction was achieved in 96% (24/25) cases. There was 1 minor intra-operative vascular injury, repaired immediately successfully, and no late wound infections, or other visceral complications. One patient reported new onset sensory numbness which resolved after the first review. Two patients reported erectile dysfunction thought to be caused by the initial injury. One patient had asymptomatic plate loosening. None required revision surgery.

Despite the obvious learning curve, we found this approach safe and it did not compromise accuracy of reduction in well selected patients, but early surgery within 10–14 days is recommended to aid optimal reduction.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 32 - 32
1 Oct 2014
Motesharei A Rowe P Blyth M Jones B MacLean A Anthony I
Full Access

Unicompartmental knee arthroplasty (UKA) has been gaining popularity in recent years due to its perceived benefits over total knee arthroplasty (TKA), such as greater bone preservation, reduced operating-room time, better post-operative range of motion and improved gait. However there have been failures associated with UKA caused by misalignment of the implants that have lead to revisions. To improve the implant alignment a robotic guidance system called the RIO Robotic Arm has been developed by MAKO Surgical Corp (Ft. Lauderdale, FL), which is designed to give improved accuracy compared to traditional UKA using cutting jigs and other manual instrumentation.

The University of Strathclyde in association with Glasgow Royal Infirmary has undertaken the first independent RCT trial of the MAKO system against the Oxford unicompartmental knee arthroplasty – a conventional UKA used in the UK. Motion analysis was used in order to obtain a quantitative assessment of their movement. The results from a total of 51 patients (23 MAKO, 28 Oxford) that underwent a one year post-operative biomechanical assessment were investigated.

Motion analysis showed that during level walking the MAKO group achieved a higher knee excursion during the highest flexion portion of the weight bearing stage of the gait cycle (foot-strike to mid-stance) compared to the Oxford group (18.6° and 15.8° respectively). This difference was statistically significant (p-value = 0.03). Other knee excursion values that were compared were from mid-stance to terminal stance, and overall knee flexion. No statistically significant differences were seen in either of these measurements. A subsequent comparison of both MAKO and Oxford groups with a matched normal cohort (50 patients), demonstrated that there wasn't a statistically significant difference between the MAKO group and the normal knees during mean knee excursion from foot-strike to mid-stance (18.6° and 19.5° respectively, p-value 0.36). However the Oxford group, with a lower knee excursion was found to be significantly different to our normal control group (15.8° and 19.5° respectively, p-value < 0.001).

This suggests that the robotic-assisted knees behaved more similarly to normal gait during this phase of the gait cycle than those of the conventional group. While significant differences in gait were found between the Oxford and MAKO groups, further work is required to determine if this results in improved knee function that is perceptible to the patient.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_12 | Pages 51 - 51
1 Jul 2014
Jones R
Full Access

Infection after total knee arthroplasty poses formidable challenges to the surgeon. Once an infection is diagnosed, the identification of the organism and its sensitivity to antibiotics is essential. The host's healing capacity is vital. Optimisation of modifiable comorbidities, supplemental nutrition and cessation of smoking can improve wound healing. Surgical goals include debridement of necrotic tissue and elimination of the dead space. Intravenous antibiotics and a two-stage protocol are the standard of care. At our institution, the first stage is performed with an implant and antibiotic-cement composite. This articulating spacer maintains limb length and tissue compliance. The patient can maintain a functional status between stages. Definitive reconstruction is more readily accomplished with this method in contrast to the static spacer approach. The clinical efficacy of this protocol has been well documented in the literature.