The aim of this study was to define normal, borderline, and abnormal parameters for the morphology of the proximal femur, in the context of the cam deformity, by studying asymptomatic individuals with normal clinical examination and no osteoarthritis from the general population.
Despite the satisfactory short-term implant survivor-ship, there is an increasing concern that the metal-on-metal hip resurfacing arthroplasty (MoMHRA) release large amount of very small wear particles and metal ions. The periprosthetic soft-tissue masses such as pseudotumours are being increasingly reported. These were found be locally destructive, requiring revision surgery in most patients. It has been suggested that either an immune reaction or cytotoxic effect of chromium(Cr) or cobalt(Co) may play a role in its aetiology. However, the effect of the phagocytosis of implant-associated metal nanoparticles on macrophages has not been elucidated. The aim of this study was to investigate the in vitro viability and proliferative response of murine macrophages to clinically relevant metal nanoparticles and ions.
At the end of day 1 and 4, two methods were used to quantify cell proliferation and viability. The AlamarBlue assay(Invitrogen) incorporates a fluorimetric growth indicator and the fluorescence signal correlates with metabolic activity of the cells. LIVE/DEAD stain kit(Molecular Probes) contains two fluorescent dyes to stain living cells green and dead cells red. The viability was calculated by the number of live cells divided by total cell numbers. Inter-group comparisons were performed using one-way ANOVA with Tukey post hoc test. Differences at p<
0.05 were considered to be significant.
Recently, a series of locally destructive soft tissue pseudotumour has been reported in patients following metal-on-metal hip resurfacing arthroplasty (MoMHRA), requiring revision surgery in a high percentage of patients. Based on the histological evidence of lymphocytic infiltration, a delayed hypersensitivity reaction to nickel (Ni), chromium (Cr) or cobalt (Co) has been suggested to play a role in its aetiology. The aim of this study was to investigate the incidence and level of hypersensitivity reaction to metals in patients with pseudotumour.
Group 1: MoMHRA patients with pseudotumours, detected on the ultrasound and confirmed with MRI (n=6, 5 F:1 M, mean age 53 years); Group 2: MoMHRA patients without pseudotumours (n=13, 7 F:6 M, mean age 55 years); and Group 3: age-matched control subjects without metal implants (n=6, 4 F:2 M, mean age 54 years). Lymphocyte transformation tests (LTT) were used to measure lymphocyte proliferation responses to metals. Peripheral blood mononuclear cells were isolated from heparinized blood samples using standard Ficoll–Hypaque® (Pharmacia). The PBMC were cultured at a cell density of 106 cells/mL. Culture was set up in the presence of either:
medium alone; nickel chloride (Sigma; 10-4M-10-6M); cobalt chloride (10-4M-10-6M); and chromium chloride (10-4M-10-6M). After 5 days of culture, cells were pulsed with [3H]-thymidine and proliferation was assessed by scintillation counting. The stimulation index (SI) was calculated by the ratio of mean counts per minute of stimulated to unstimulated cultures. A SI value of greater than 2.0 was interpreted as a positive result.
Current intervention strategy is focussed on prevention of initial device colonisation and inhibition of genes encoding biofilm formation.
Determine the minimum inhibitory concentration (MIC) of betadine. Investigate the effect of betadine on icaADBC operon encoded staphylococcal biofilm formation. Investigate wether betadine can prevent bacterial adherence and biofilm formation by inhibition of the encoding genes.
Total RNA for cDNA synthesis was isolated from bacterial at different twofold dilutions of betadine concentrations. Real time polymerase chain reaction was used to quantify effects of betadine on gene expression pattern of the icaADBC operon using the constitutively expressed gyrB gene as internal control. Bacterial was cultivated on polystyrene plates coated with different sub-inhibitory and clinical in-use doses of betadine to assess surface adherence.
A step-wise reduction of biofilm was observed at increasing sub-inhibitory doses of betadine (p<
0.0001). IcaA expression correlated with biofilm formation in staphylococcal organisms. Decrease in icaA expression was strongly associated with an increase in expression in the biofilm repressor gene, icaR. The repressive effect of betadine on biofilm formation by Staphylococcal bacteria is by a separate mechanism from its bacteriostatic mechanism of action.
Prevention of bacterial surface attachment as demonstrated by this study is suggestive that these compounds could be developed as a surface coating agents for orthopaedic implants.
Tribological studies of hip arthroplasty suggest that larger diameter metal-on-metal (MOM) articulations would produce less wear than smaller diameter articulations. Other advantages using these large femoral heads implants include better stability with lower dislocation rates and improved range of motion. The aim of the present study was to compare chromium (Cr), cobalt (Co) and titanium (Ti) ion concentrations up to 1-year after implantation of different large diameter MOM total hip arthroplasty (THA).
Statistical group comparison revealed significant difference for Cr (p=0.006), Co (p=0.047) and Ti (p=<
0.001). With Biomet implants presenting the best results for Cr and Co and Zimmer the highest Ti level.
Metal on Metal Hip Resurfacing Arthroplasty (MoMHRA) has gained popularity due to its perceived advantages of bone conservation and relative ease of revision to a conventional THR if it fails. Known MoMHRA-associated complications include femoral neck fracture, avascular necrosis/collapse of the femoral head/neck, aseptic loosening and soft tissue responses such as ALVAL and pseudotumours. This study’s aim was to assess the functional outcome of failed MoMHRA revised to THR and compare it with a matched cohort of primary THRs.
Although many causes of FAI are described, the vast majority of patients give no history of previous hip disease. The purpose of this study was to investigate the extent to which FAI has an underlying genetic basis, by studying the siblings of patients undergoing surgery for FAI and comparing them with controls.
Patello-femoral instability (PFI) affects 40 individuals per 100,000 population and causes significant morbidity. The causes of patello-femoral instability are multi-factorial, and an isolated anatomical abnormality does not necessarily indicate instability. Patello-femoral subluxation ranges from 0% (stable patella tracking) to 100% (dislocation) and there is an established relationship between the amount of subluxation and anterior knee pain. Traditionally, magnetic resonance (MR) imaging and standard radiographs are used to guide the clinician towards a suitable corrective procedure for PFI. The multi-factorial nature of patello-femoral instability is not addressed with current imaging techniques. This study aims to address which anatomical variables assessed on MR images are most relevant to patello-femoral subluxation. This information will aid surgical decision making, particularly in selecting the most appropriate reconstructive surgery. A retrospective analysis of MR studies of 60 patients with suspected patello-femoral instability was performed. All patients were graded for degree of subluxation using a dynamic MR scan. The patient scans were assessed for the presence of a specific range of anatomical variables:
patella alta, (modified Insall-Salvatti) patella type (Wiberg classification) trochlea sulcus angles for bone and cartilage surfaces the distance of the vastus medialis obliquis (VMO) muscle from the patella trochlea and patella cartilage thickness the horizontal distance between the tibial tubercle and the midpoint of the femoral trochlea (TTD) patella engagement – the percentage of the patella height that is captured in the trochlea groove in full extension. The Wilk’s Lambda test for multi-variate analysis was used to establish whether any relationship was present between the degree of patello-femoral instability and bony or soft tissue anatomical variables. Non-parametric statistical tests were applied across the groups and within the groups to assess their relative significance. The following variables showed a significant relationship with patellofemoral subluxation; distance of the VMO from the patella (<
0.001), TTD (<
0.001), patella engagement (0.001), sulcus angles (0.004) and patella alta (0.005). This study agrees with previous work showing a significant correlation between subluxation and trochlea sulcus angle and TTD. This is the first study to establish a significant correlation between patella engagement and radiological instability. The lower the percentage engagement of the patella in the trochlea, the greater the degree of patello-femoral instability. Patella engagement showed a more significant relationship with subluxation than patella alta. We report a new method of predicting patello-femoral instability by measuring the overlap of the patella in the trochlea groove.
Participants were classified as:
Normal morphology, no clinical features Abnormal morphology, no clinical features Abnormal morphology, clinical signs but no symptoms Abnormal morphology with symptoms and signs Osteoarthritis.
100% of medial compartments showed full thickness anteromedial loss with preservation of the posteromedial cartilage. When present, the meniscus was extruded in 96% of cases. 90% of lateral compartments were normal and none had full thickness cartilage loss. However 10% showed high signal in the tibial plateau. There was a highly reproducible pattern of osteophyte formation; 94% posteromedial and posterolateral aspect of medial femoral condyle; 90% medial tibial; 80% medial femoral and 84% lateral intercondylar notch.
patients’ pre-operative demographics for age, weight, height, BMI, intraoperative variables such as the operating surgeon (n=2), insert and component sizes, and clinical assessment criteria including pre-operative and five-year post-operative Oxford knee (OKS) and Tegner (TS) scores.