header advert
Results 61 - 80 of 104
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 387 - 387
1 Dec 2013
Kurtz S MacDonald D Higgs G Gilbert J Klein GR Mont M Parvizi J Kraay M Rimnac C
Full Access

Introduction:

Degradation of modular head-neck tapers was raised as a concern in the 1990s (Gilbert 1993). The incidence of fretting and corrosion among modern, metal-on-polyethylene and ceramic-on-polyethylene THA systems with 36+ mm femoral heads remains poorly understood. Additionally, it is unknown whether metal debris from modular tapers could increase wear rates of highly crosslinked PE (HXLPE) liners.

The purpose of this study was to characterize the severity of fretting and corrosion at head-neck modular interfaces in retrieved conventional and HXLPE THA systems and its effect on penetration rates.

Patients & Methods:

386 CoCr alloy heads from 5 manufacturers were analyzed along with 166 stems (38 with ceramic femoral heads). Metal and ceramic components were cleaned and examined at the head taper and stem taper by two investigators. Scores ranging from 1 (mild) to 4 (severe) were assigned in accordance with the semi-quantitative method adapted from a previously published technique. Linear penetration of liners was measured using a calibrated digital micrometer (accuracy: 0.001 mm). Devices implanted less than 1 year were excluded from this analysis because in the short-term, creep dominates penetration of the head into the liner.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 22 - 22
1 May 2013
Parvizi J
Full Access

Direct anterior approach (DAA) using the Hueter interval for total hip replacement (THA) provides an inter-nervous and inter-muscular access to the hip joint. Although it is technically demanding, the learning curve has been shown to be around 40 cases and 6 months in a high-volume joint surgeon's practice. A level-one study has demonstrated that DAA provides equal or better results and an equivalent rate of complications when compared to the highly utilized direct lateral approach. Using the available evidence to perform a multi-criteria decision analysis we demonstrated that DAA can be the most efficient approach to perform THA. From our standpoint, there is no reason to speculate a surgical approach with such advantages will be abandoned in the future. The DAA is here to stay, and may become the gold standard for THA.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 102 - 102
1 May 2013
Parvizi J
Full Access

Total knee arthroplasty is an operation that can be performed with or without the use of tourniquet. Two systematic reviews and meta-analyses of the available literature have demonstrated that the use of tourniquet leads to a reduction in blood loss and also shortens the operative time. The opponents for use of tourniquet cite development of complications such as skin bruising, neurovascular injury, and metabolic disturbances as a deterrent for the use of tourniquet. Although the latter may be true for some patients such as those with previous vascular grafts, there is little evidence that routine use of tourniquet during TKA results in any of the above complications. The use of tourniquet on the other hand provides a bloodless field that allows the surgeon to perform the procedure with expediency and optimised visualisation. Blood conservation has gained extreme importance in recent years because of increased understanding of problems associated with blood transfusion such as increased surgical site infection (due to immunomodulation effect), increased length of hospital stay, increased cost and so on. Based on our understanding of the available evidence, we believe that routine use of tourniquet during TKA is justified and a good surgical practice.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 280 - 280
1 Mar 2013
Nevelos J Boucher F Parvizi J Nessler JP Kolisek FR
Full Access

A novel cementless tapered wedge femoral hip implant has been designed at a reduced length and with a geometry optimized to better fit a wide array of bone types (Accolade II, Stryker, Mahwah, USA). In this study, finite element analysis (FEA) is used to compare the initial stability of the new proposed hip stem to predicate tapered wedge stem designs. A fit analysis was also conducted. The novel stem was compared to a predicate standard tapered stem and a shortened version of that same predicate stem.

Methods

The novel shortened tapered wedge stem geometry was designed based on a morphological study of 556 CT scans. We then selected 10 discrete femoral geometries of interest from the CT database, including champagne fluted and stove pipe femurs. The novel and the predicate stems were virtually implanted in the bones in ABAQUS CAE. A total of thirty FEA models were meshed with 4 nodes linear tetrahedral elements. Bone/implant interface properties was simulated with contact surface and a friction coefficient of 0.35. Initial stability of each stem/bone assembly was calculated using stair-climbing loading conditions. The overall initial stability of the HA coated surface was evaluated by comparing the mean rotational, vertical, gap-opening and total micromotion at the proximal bone/implant interface of the novel and predicate stem designs.

To characterize the fit of the stem designs we analyzed the ratio of a distal (60 mm below lesser trochanter) and a proximal (10 mm above lesser trochanter) cross section. A constant implantation height of 20 mm above the lesser trochanter was used. The fit of the stems was classified as Type 1 (proximal and distal engagement), Type 2 (proximal engagement only) and Type 3 (distal engagement only).

Results

The mean % micromotion of the HA coated surface greater than 50 mm was lowest at 40.2% (SD 11.5%) for the novel tapered wedge stem compared to the clinically successful predicate stem design (Accolade TMAZ, Stryker, Mahwah, USA) at 44.9% (SD 13.2%) and its shortened version at 48.5% (SD 9.0%) as shown in Figure 1. Improved initial stability of the new stem was also confirmed for rotational, vertical and gap-opening micromotion. However, there was no statistically significant difference.

The novel tapered stem design showed a well balanced proximal to distal ratio throughout the complete size range. The novel tapered stem design showed a reduced percentage of distal engagements (2.8%) compared to the predicate standard stem (17.2%). In the 40 to 60 year old male group the distal engagement for the standard stem increases (28.2%), whereas the distal engagements for the novel stem remains unchanged (1.3%).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 232 - 232
1 Mar 2013
Kurtz S MacDonald D Kocagoz S Tohfafarosh M Parvizi J Klein GR Lee G Marshall A Mont M Kraay M Stulberg B Rimnac C
Full Access

Introduction

Sequentially annealed highly crosslinked polyethylenes (HXLPEs) were introduced in total knee replacement (TKR) starting in 2005 to reduce wear and particle-induced osteolysis. Few studies have reported on the clinical performance of HXLPE knees. In this study, we hypothesized that due to the reduced free radicals, sequentially annealed HXLPE would have lower oxidation levels than gamma inert-sterilized controls.

Methods

145 tibial components were retrieved at consecutive revision surgeries at 7 different surgical centers. 74 components were identified as sequentially annealed HXLPE (X3, Stryker) while the remainder (n = 71) were conventional gamma inert sterilized polyethylene. The sterilization method was confirmed by tracing the lot numbers by the manufacturer. The conventional inserts were implanted for 1.7 years (Range: 0.0–9.3 years), while the X3 components were implanted 1.1 years (Range: 0.0–4.5 years). Surface damage was assessed using the Hood method. Oxidation analysis was performed in accordance with ASTM 2102 following submersion in boiling heptane for 6 hours to remove absorbed lipids. 30 of the conventional and 29 of the HXLPE inserts were available for oxidation analysis.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 108 - 108
1 Mar 2013
Higgs G Kurtz S Hanzlik J MacDonald D Kane WM Day J Klein GR Parvizi J Mont M Kraay M Martell J Gilbert J Rimnac C
Full Access

Introduction

Wear debris generation in metal-on-metal (MOM) total hip arthroplasty (THA) has emerged as a compelling issue. In the UK, clinically significant fretting corrosion was reported at head-taper junctions of MOM hip prostheses from a single manufacturer (Langton 2011). This study characterizes the prevalence of fretting and corrosion at various modular interfaces in retrieved MOM THA systems used in the United States.

Methods and Materials

106 MOM bearing systems were collected between 2003 and 2012 in an NIH-supported, multi-institutional retrieval program. From this collection, 88 modular MOM THA devices were identified, yielding 76 heads and 31 stems (22 modular necks) of 7 different bearing designs (5 manufacturers) for analysis. 10 modular CoCr acetabular liners and 5 corresponding acetabular shells were also examined. Mean age at implantation was 58 years (range, 30–85 years) and implantation time averaged 2.2 ± 1.8 years (range, 0–11.0 years). The predominant revision reason was loosening (n=52). Explants were cleaned and scored at the head taper, stem taper, proximal and distal neck tapers (for modular necks), liner, and shell interfaces in accordance with the semi-quantitative method of Goldberg et al. (2002).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 107 - 107
1 Mar 2013
Kurtz S MacDonald D Parvizi J Klein GR Lee G Marshall A Mont M Kraay M Stulberg B Malkani AL Rimnac C
Full Access

Introduction

The purpose of this multicenter study was to assess the oxidative stability, mechanical behavior, wear and reasons for revision of 2nd generation sequentially annealed HXLPE, X3, and compare it to 1st generation XLPE, Crossfire. We hypothesized that X3 would exhibit similar wear rates but lower oxidation than Crossfire.

Methods

182 hip liners were consecutively retrieved during revision surgeries at 7 surgical centers and continuously analyzed over the past 12 years in a prospective, multicenter study. 90 were highly crosslinked and annealed (Crossfire; Implanted 4.2±3.4 years, max: 11 years), and 92 were highly crosslinked and annealed in 3 sequential steps (X3; Implanted 1.2±1.5 years; max: 5 years). Oxidation was characterized in accordance with ASTM 2102 using transmission FTIR performed on thin sections (∼200μm) from the superior/inferior axis. Mechanical behavior was assessed via the small punch test (ASTM 2183).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 206 - 206
1 Sep 2012
Cashman J MacKenzie J Parvizi J
Full Access

Background

The diagnosis of Periprosthetic Joint Infection (PJI) is a considerable challenge in total joint arthroplasty. The mainstay for diagnosis of PJI is a combination of serological markers, including C-reactive protein (CRP), along with joint aspirate for white cell count, differential and culture. The aim of this study was to examine the use of synovial fluid CRP in the diagnosis of PJI.

Material & Methods

Synovial fluid samples were collected prospectively from patients undergoing primary and revision knee arthroplasty. Samples were assessed for CRP, cell count and differential. Three groups were analyzed; those undergoing primary knee arthroplasty, aseptic knee arthroplasties and infected arthroplasties. Demographic data, along with associated medical co-morbidities, were collected,. Statistical analysis was performed. Synovial fluid CRP was correlated with serum CRP values. Sensitivity and specificity were calculated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 2 - 2
1 Sep 2012
Wuestemann T Bastian A Parvizi J Nessler J Kolisek F Nevelos J
Full Access

Introduction

The origins of the uncemented tapered wedge hip stem design currently offered by several orthopaedic device companies can be linked back to the cemented Straight Mueller type stem design first used in 1977. The design, a wedge shape with a taper angle of 6 degrees, maintains a single medial curvature for all sizes and increases laterally in the width to accommodate different size femurs. Although evolutionary improvements have been made over the years the basic body geometry of the stem has stayed mainly unchanged with excellent clinical survivorship. Over the past decade, the demographics of hip replacement have changed, with a large increase in younger male patients in the age range of 40 to 60 years. In this study the femoral fit of a novel tapered stem, designed to fit a wide array of patient types, is compared to a standard predicate tapered stem design.

Methods

A bone morphology study was performed on a patient population of 556 patients using three dimensional digital data from CT-scans. To characterize the fit of the stem designs we analyzed the ratio of a distal (60mm below lesser trochanter) and a proximal (10mm above lesser trochanter) cross section. The same measurements were taken with the standard tapered stem design and the novel tapered stem design, with a given constant implantation height of 20mm above the lesser trochanter. The fit of the stems was classified as Type 1, where there was both proximal and distal engagement, Type 2, proximal engagement only, Type 3, distal engagement only. The distal and proximal engagement, Type 1, was specified with a maximum engagement difference of 2mm proximal to distal.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 457 - 457
1 Nov 2011
Ketonis C Ayier A Barr S Adams CS Shapiro IM Hickok NJ Parvizi J
Full Access

Infection poses one of the greatest medical challenges, one further complicated by bacterial biofilm formation that renders the infection antibiotic insensitive. The goal of this investigation was to covalently link the antibiotic vancomycin (VAN) to a bone allograft so as to render the tissue inhospitable to bacterial colonization and the subsequent establishment of infection. We could achieve uniform tethering of the antibiotic to the allograft with minimal disruption of the underlying bone structure. The tethered VAN remained active against gram-positive organisms with no detectable S.aureus colonization. Additionally, the grafted VAN prevented biofilm formation, even in protected topographical niches. Attachment of the antibiotic to the allograft surface was robust-the stabilized VAN remained active for long time periods. Osteoblasts cultured on the VAN-allograft evidenced no changes in cellular phenotype. We opine that this new chimeric construct represents a superior transplantable substrate with a plethora of applications in medicine, dentistry and surgery.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 449 - 449
1 Nov 2011
Ketonis C Ayier A Shapiro I Parvizi J Hickok N
Full Access

Use of allograft bone has become standard for bridging defects unlikely to heal by simple fixation and routinely used in revision arthroplasties for implant stabilization. Unfortunately, this decellularized allograft provides an ideal surface for bacterial colonization, necessitating repeated surgeries, extensive debridement and lengthy antibiotic treatments. With up to 18% infection rate following allograft surgeries, a need for more effective means to prevent this process is evident. We describe a novel modification of native bone allografts that renders their surface bactericidal while increasing the effectiveness of systemic antibiotic treatments.

Allograft modification: Morselized human bone was washed extensively and sequentially coupled: 2X with Fmoc-aminoethoxyethoxyacetate (Fmoc-AEEA); deprotected with 20% piperidine in Dimethylformamide (DMF); and then coupled with vancomycin (VAN) for 12–16 hours. The VAN-bone was washed extensively with DMF and PBS for at least 1 day. VAN immuno-fluorescence: Control or VAN-bone was washed 5X with PBS, blocked with 10% FBS (1hr), incubated with rabbit anti-VAN IgG (4oC, 12h) followed by an Alexa-Fluor 488-coupled goat anti-rabbit IgG (1hr), and visualized by confocal laser microscopy. Antibiotic Activity. Equal dry weights of control and VANbone were sterilized with 70% ethanol, rinsed with PBS, and incubated with either Staphylococcus aureus (S. aureus) or Escherichia Coli (Ci=104 cfu) in TSB, 37oC, for 2, 5, 8 and 12 hrs. Antibiotic treatment: Clinical grade vancomycin was added to the solution with bacteria or following infection at a final concentration of 10μg/ml. Bacterial counts: Non-adherent bacteria were removed by washing and adherent bacteria suspended by sonication in 0.3% Tween-80 for 10mins followed by plating on 3M® Petrifilms. Bacterial visualization: Non-adherent bacteria were removed by washing extensively with PBS and adherent bacteria stained with the Live/Dead BacLight Kit (20mins, RT) to cause viable bacteria to fluoresce green. Samples were visualized by confocal microscopy.

In comparison to controls, VAN-bone consistently reduced the graft bacterial load by ~90% at all time points. After staining and visualization of adherent bacteria, biofilm formation was apparent on controls by 12 hrs and absent from VAN-bone. E.coli, a gramnegative organism that is not sensitive to VAN, readily colonized both control and VANbone, confirming retention of VAN specificity. We then evaluated VAN-bone activity in a system that modeled systemic antibiotic therapy and antibiotic prophylaxis. In the absence of solution antibiotics, VAN-bone exhibited a significant decrease in bacterial colonization as compared to controls. When 10 μg/ml VAN was added to the medium for the last 4 h (modeling systemic antibiotic therapy), colonization of control surfaces was reduced, while colonization of VAN-allograft was almost eliminated. When 10 μg/ml VAN was added concomitantly with S. aureus, VAN-bone colonization was undetectable, while colonization of control surfaces still occurred.

We have previously described an antibiotic-tethered allograft that resists bacterial colonization. In this abstract, we test this technology with an vitro model of bone implantation in the presence of solution antibiotics. In these models, solution antibiotics failed to prevent infection of control bone while completely clearing the bacteria on VAN-bone. Furthermore, VAN bone exhibited high activity against S. aureus, a gram positive organism, whereas it was ineffective against E. coli, a gram negative organism. The specificity of the tethered antibiotic supported the view that the antibacterial properties of the allograft were related to the tethered antibiotic and not to undefined aspects of the attachment chemistry. In terms of antibacterial activity, when challenged with 104 CFU S. aureus (with concentrations reaching > 107 CFU by 24 h), the antibiotic -modified allograft consistently decreased bacterial colonization by > 90%; S. aureus inocula < 102 CFU resulted in no detectable colonization of the VAN-allograft. Thus, development of these allografts may not only combat allograft colonization but increase the effectiveness of prophylactic antibiotics to ultimately result in a new therapy for allograft-associated infection.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 262 - 262
1 Jul 2011
Resterpo C Parvizi J Sharkey PF Pour AE Haytmanek CT Roberts N Rothman RH
Full Access

Purpose: Recently an orthopedic manufacturer has introduced a gender specific knee design implying that there is a substantial anatomical difference between the genders. If such concept is true then TKA prosthesis implanted in the female population over the last decades, by definition, must have suboptimal outcome when compared to the male patients. The purpose of this study was to examine the functional outcome, the incidence of complications, and the need for revision between the two genders receiving the same knee design.

Method: The study selected a matched group of 150 men and 250 women undergoing TKA at our instituion. The patients were matched for age, BMI, pre-op diagnosis, comorbidities, race, mode of fixation, and the type of implant. Other demographic, surgical, and medical factors between the two genders were similar. Both pre-op and post-op functional scores were compared between the two groups. Pre-op and post-op radiographic images were assessed for implant fit.

Results: There was a significant improvement in functional outcome as measured by Knee Society score, WOMAC, and SF-36 for all patients. The improvement in functional outcome was not different between the two groups. The incidence of complications, reoperations, and need for revision between the two genders was also not significantly different.

Conclusion: Total knee arthroplasty continues to be an effective surgical procedure. Both genders appear to enjoy relief of pain and improvement of function equally. Based on this retrospective study the use of non-gender specific knee prosthesis did not seem to result in suboptimal outcome in female patients. There appears to be little merit in introduction of gender specific knee designs when previous non-gender specific prosthesis appeared to function well in both genders.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 251 - 251
1 Jul 2011
Parvizi J Bican O Bozic K Peters C
Full Access

Purpose: Hip arthroscopy has been used at an increasing frequency over the last few years. Majority of patients undergoing hip arthroscopy are young and active individuals who seek definitive therapy for a painful hip condition and wish to avoid undergoing a hip replacement. Although relatively successful, complications following hip arthroscopy occur. This multi-institutional study presents a worrisome and previously unrecognized complication of hip arthroscopy, namely chondrolysis that lead to accelerated development of end-stage arthritis.

Method: Using the computerized database in each institution, patients undergoing total hip arthroplasty between 1999–2008 who had received hip arthroscopy prior to arthroplasty were identified. 39 patients were identified to have undergone at least one hip arthroscopy on the affected hip prior to arthroplasty. There were 21 female and 18 male patients. The mean age of patients at the time of hip arthroscopy was 45.9 years. Data regarding demographics, comorbidities, preoperative diagnosis, number of previous procedures, and the details of the surgical procedure were compiled. Radiographs were evaluated.

Results: The median time from arthroscopy to arthroplasty was 14.8 months (range 2.2 months to 7 years). Fourteen patients (35%) underwent THA within 12 months of a previous hip arthroscopy and in nine of these patients the indication for hip arthroscopy was labral tear debridement. These patients despite having none to minimal arthritis at the time of arthroscopy developed accelerated arthritis within a year that necessitated hip replacement.

Conclusion: Hip arthroscopy can cause accelerated degenerative arthritis of the hip in some patients. We believe the subset of our patients who developed arthritis so early after hip arthroscopy may have suffered chondrolysis and/or chondral injury during the arthroscopy that resulted in progressive and aggressive arthritis of the hip within 12 months. Hip arthroscopy should be reserved for a select group of patients. All measures to minimize the possibility of chondrolysis and/or chondral injury should be exercised.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 250 - 250
1 Jul 2011
Parvizi J Pulido L Matar M Marchetto N Og B
Full Access

Purpose: Femoroacetabular impingement (FAI) is recognized as an etiological risk factor for hip arthritis. The potential for joint preserving surgical techniques that may delay the progression to early arthritis and retard the possibility of arthroplasty at a young age is promising. This study presents the outcome of surgical treatment of FAI through a less invasive technique performed through a modified Smith-Peterson approach without hip dislocation, or arthroscopy.

Method: Using an institutional database, a total of 72 patients (80 hips) with radiographic and clinical diagnosis of FAI who underwent direct anterior femoroacetabular osteoplasty (FAO) were identified. Preoperative and postoperative functional evaluation was performed on these patients. The operative findings were recorded in detail and evaluated with regard to outcome.

Results: Intraoperative diagnosis of labral tear and osteochondral lesions in the anterosuperior acetabulum was confirmed in all cases. The surgical approach provided adequate access to allow labral repair and osteoplasty of the femoral neck and the acetabulum, whenever needed. There were no intraoperative complications. All patients experienced a significant improvement in function as measured by modified Harris hip and SUSHI scores. Majority (85%) of the patients were satisfied with the outcome of the surgery. In addition, Health Survey SF-36 showed most patients felt their health had improved significantly. The predictors of poor outcome were previous hip scope, lack of labrum for repair, large chondral lesions, and workman’s compensation status.

Conclusion: This study presents the early results of a less invasive surgical treatment for femoroacetabular impingement. This ongoing study shows that the described technique seems to be a viable approach for treatment of this painful condition in the young.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 275 - 275
1 Jul 2011
Ghanem E Pawasarat I Restrepo C Azzam K May L Austin MS Parvizi J
Full Access

Purpose: The purpose of our study is to compare hips to knees in regards to the cost per increase in function, to determine the relationship of economic investment to improved quality of life.

Method: During the year 2005, a total of 23 TKA and 41 THA revisions were performed for aseptic mechanical failure. Patients were enrolled prospectively and quality of life questionnaires including the SF-36, WOMAC, Harris Hip Score (HHS), and Knee Society Score (KSS) were collected prior to and following their procedure at two year follow-up. The total cost of the procedure including the hospital, implant, and surgeon fee were implemented in a cost effectiveness model to calculate the mean cost per SF-36, WOMAC, and HHS or KSS point gained. Demographical variables and co-morbidities were collected to determine risk factors for low cost-effectiveness.

Results: The majority of patients had significant improvement in SF-36, WOMAC, HHS and KSS scales. Patients with THA revisions experience a cost per point increase for HHS of $3,000, and $500 per point SF-36 compared to knee patients who experienced a cost per point increase for KSS of $2,000, and $2,800 per point SF-36. The WOMAC exhibited similar cost effectiveness in the subscales of pain, stiffness and functioning.

Conclusion: There are few studies that have compared the cost effectiveness of total joint arthroplasty revision procedures. Given the increasing cost of health care expenditures, prioritization of funding for the different health practices will become necessary. This study demonstrates that revision THA and TKA are relatively cost effective procedures compared to other non-orthopaedic interventions.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 156 - 157
1 May 2011
Wuestemann T Bastian A Schmidt W Cedermark C Streicher R Parvizi J Rothman R
Full Access

Introduction: Clinical experience has shown that addressing variations in bone morphology is important in the development of successful hip implant designs. Numerous studies of femoral bone morphology have been published utilizing various techniques. This study has developed a method which consistently measures large quantities of 3-dimensional digital femura geometry segmented from computed tomography (CT) scans and can accurately make anatomical measurements from these images

Methods: CT images of left femora on five hundred fifty six left femura (57% male, 43% female), consisting of 69% Caucasian, 16% Asian and 14% unknown were analyzed. The average age was 66 years, ranging from 40 to 93 years. Segmentation of the outer cortical, inner cortical, and marrow boundaries were consistently performed over all CT scans. The positions identified on the reference bone are transformed to the equivalent position on the clinical bone images, from which the dimensional data is extracted and stored. The mediolateral width (MLW), medial offset (MO) and lateral offset (LO) were measured in 10mm increments, ranging from 20mm above the lesser trochanter (LT) to 130mm below the lesser trochanter. The canal flare index was defined as a ratio of the mediolateral width at a section 20mm above the lesser trochanter to the mediolateral width at the isthmus level.

Results: The mean mediolateral width at 20mm above the lesser trochanter was 47.0 ± 4.5 (35.1–61.8; n=556). Noble reported 45.4 ± 5.3 (31.0–60.0; n=200), Husmann reported in a neck oriented study 46.3 ± 6.9 (27.6–63.6; n=310) and Laine reported 47.1 ± 4.9 (n=50). The mean medial offset at a section 20mm above the lesser trochanter was 25.1 ± 2.9 (16.7–33.4). In the study by Husmann, a mean of 25.0 ± 5.2 (9.4–45.5) was reported. The mean canal flare index was 4.49 ±.8. Noble reported a mean canal flare index of 3.80 ±.074, Husmann 3.81 ±.83 and Laine 4.3 ±.93.

Discussion: In general, the study showed minor differences to published data of proximal bone morphology. However, this more powerful study has shown that there is a higher mean canal flare index than determined by Noble and a similar mean canal flare index as determined by Laine. As reported by Laine, the canal flare index varies significantly with the placement of measurements in the canal. In this study the measurements were performed in a plane oriented by the femoral neck as a hip stem would be placed. The CFI over the isthmus width showed a greater correlation than previously shown by Noble. The novel software tool allows for anatomical measurements that can be applied to an unlimited population size enabling further applications and studies.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 298 - 298
1 May 2009
Jaberi M Eslampour A Haytmanek C Parvizi J Ghanem E Purtill J
Full Access

Persistent wound drainage after total joint arthroplasty (TJA) has been associated with a higher incidence of superficial and deep periprosthetic infection but the predictors for prolonged drainage and its outcome have not been thoroughly studied.

A consecutive series of 7,153 TJA cases performed between 2000 and 2006 at our institute, were recruited into this study. There were 301 cases (4.2%) of persistent wound drainage, defined as discharge from the wound for > 48 hours. The cases were matched in a 2:1 ratio for type of surgery, joint replaced, and date of surgery.

This study identified higher BMI (p< 0.005), malnutrition as defined by serum albumin< 3.4g/dl (p< 0.04), longer operative time (p< 0.01), and higher medical comorbidities, in particular diabetes (p< 0.001) as important risk factors for persistent wound drainage. In addition, patients in the drainage group were more likely to have a peak INR of > 1.5 (p< 0.001) during their hospital stay. Patients with wound drainage had a significantly lower hemoglobin postoperatively (p< 0.01) that necessitated greater number of postoperative allogenic transfusions (p=0.004). The hospital length of stay for the drainage group was also significantly higher (p< 0.005). One of the major risk factors for development of deep infection was prolonged drainage (> 7 days). In the deep hematoma and periprosthetic subgroups, the mean of delay in treatment was 6 days in those with retention of the prosthesis and successful outcome, and 9.5 days for those with failure of incision and drainage leading to resection arthroplasty (p= 0.03).

72% of the patient were successfully treated by oral or intravenous antibiotics. 27% required at least one re-operation for deep hematoma and 13% developed deep periprosthetic infection, resulting in 6% rate of resection arthroplasty. 1.5% of those with drainage remained in girdlestone status.

This study suggests early surgery for persistent drainage and avoidance of aggressive anticoagulation.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 308 - 308
1 May 2009
Elie G Pulido L Restrepo C Houssock C Parvizi J
Full Access

Periprosthetic infection (PPI) remains the most dreaded and difficult complication of total joint arthroplasty. Although there is no definite diagnostic test for PPI, synovial leukocyte count and neutrophil percentage have been reported to have high sensitivity and specificity. However, leukocytes and neutrophils introduced into the joint during a traumatic aspiration can skew results and undermine the predictive value of this diagnostic test. This study intends to determine the diagnostic value of implementing a corrective formula frequently used in traumatic spinal taps to adjust for serum leukocytes introduced into the joint fluid during a bloody tap.

We conducted a review of all TKA aspirations of infected and non-infected patients performed at our institute from 2000 to 2005.

The following inclusion criteria were used:

(a) a red cell count (RBC) was performed on the aspirate, and

(b) a blood white cell count with differential was done within one week of aspiration.

Patients with inflammatory arthropathy or those who underwent reimplantation after PPI were excluded. Strict criteria for diagnosis of PPI were used. We previously determined at our institute the cut-off values for fluid leukocyte count (> 1760 cells/μl) and neutrophil percentage (> 73%).

The adjusted fluid leukocyte counts were calculated using the following formula:

Wadjusted = WBCobserved – [(WBCblood * RBC-fluid/RBCblood)] predicted.

A similar formula was implemented to calculate the adjusted absolute neutrophil counts.

Our cohort included 73 infected and 32 aseptic total knee arthroplasties that fulfilled the above criteria. After correcting for introduced red blood cells, cell counts of 3 infected patients dropped below the cut-off value, while the remaining 70 maintained a high cell count. However, the 3 infected patients had initial cell counts below our reported cut-offs. Of the 32 non-infected patients, 10 patients had false positive cell counts due to the presence of extremely high numbers of blood RBC. Five of the 10 false positive aspirates successfully corrected to levels below the thresholds used to diagnose infection. The aspirates that corrected had a greater number of introduced RBCs, an initial higher cell count, and 20 times more fluid WBC deducted from the initial cell count.

The corrective formula can safely adjust for RBC found in a traumatic tap and detect false positive results among non-infected TKA without compromising the diagnosis of infection. Adjusted aspirates of non-infected TKA can be expected to decrease below zero due to one of the following: adherence of the introduced systemic WBC to the joint synovium, greater rate of lysis of the introduced systemic WBC compared to the systemic RBC, laboratory errors in performing fluid cell counts.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 308 - 308
1 May 2009
Elie G Lindsay A Sharkey PF Purtill J Parvizi J Austin M
Full Access

The differential diagnosis of pain after total knee arthroplasty (TKA) should always include periprosthetic infection (PPI). The current diagnostic tools vary in sensitivity, specificity, and predictive value. Currently there is no test with an absolute accuracy for diagnosis of PPI. Furthermore, cost effectiveness of investigations has become an important issue in recent years as increased expenses can place an unnecessary heavy burden on the medical system.

We retrospectively evaluated 296 patients who underwent revision TKA at our institution during 2000–2005 and had preoperative erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) performed. The criteria used for diagnosing infection were a positive intraoperative culture on solid media, presence of an abscess or sinus tract that communicated with the joint, positive preoperative aspiration culture, and/or elevated fluid cell count and neutrophil differential of the aspirated fluid. The sensitivity, specificity, and predictive values of ESR and CRP were determined. Combinations were performed in parallel that necessitate both tests to be negative to rule out infection. The cost of each serological test was compared to that of other commonly used screening modalities.

One hundred and sixteen patients (39%) were classified as infected and 180 patients (61%) were considered non-infected. The sensitivity, specificity, positive predictive value, and negative predictive value for the ESR were: 91%, 72%, 68%, and 93%. The sensitivity, specificity, positive predictive value, and negative predictive value for the CRP were: 94%, 74%, 70%, and 95%. The sensitivity and negative predictive value for the combined studies were 96% and 95%, respectively. However, five infected patients (4%) had a normal

ESR and CRP. An organism was cultured on solid media in 4 of the 5 cases. ESR and CRP were the least costly of all the preoperative tests including radionuclide imaging and joint fluid analysis. ESR and CRP are important preoperative tests in diagnosis of PPI and their ability to clench the diagnosis in the majority of cases should not be underestimated. When combined, these simple serological tests have improved sensitivity and negative predictive value to rule out infection.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 308 - 308
1 May 2009
Ghanem E Antoci V Sharkey P Barrack R Spangehl M Parvizi J
Full Access

Serological tests including erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) are frequently used in the preoperative workup to screen for periprosthetic infection (PPI) in total hip arthroplasty (THA). The cut-off points reported in the literature are arbitrarily chosen by investigators. Similarly, the values used in laboratories to distinguish elevated results vary from one institute to another. Therefore, we intended to define the appropriate cut-off points of ESR and CRP that can be used to differentiate infection from aseptic failure of THA.

A review of our joint registry database revealed that 515 THA revisions (131 infected cases) were performed during 2000–2005. Intraoperative samples for culture were taken in all cases. The criteria used for diagnosis of infection were a positive intraoperative culture on solid media, presence of an abscess or sinus tract that communicated with the joint, positive preoperative aspiration culture, and/or elevated fluid cell count and neutrophil differential of the aspirated fluid. Non-infected patients with confounding factors that can elevate ESR and CRP including collagen vascular disease, inflammatory arthropathy, malignancy, and urinary tract infection were excluded. Receiver operator curves were used to determine the ideal cut-off point for both ESR and CRP.

The mean value of ESR in the infected group (77mm/ hr) was significantly higher compared to that of the non-infected cohort (29mm/hr) (p=0.0001). Similarly, infected patients presented with a greater mean CRP (9.8 mg/dl) than their non-infected cohort (1.48 mg/ dl) (p=0.0001). The infection threshold for ESR was 45mm/hr with a sensitivity of 85% and specificity of 79%, while the optimal cut-off value for CRP was defined as 1.6 mg/dl which yielded a sensitivity of 86% and specificity of 83%.

The optimal threshold values we determined are higher than the arbitrarily chosen values cited in the literature for ESR (30mm/hr) and CRP (1mg/dl). Although it has been previously reported that the sensitivity and specificity of CRP are far greater than that of ESR, we found that the two tests have comparable diagnostic value.