We aim to explain the significant difference in survivor-ship found between two cohorts of patients who underwent different total knee replacements. The first cohort included 70 patients who underwent Kinemax Plus total knee replacement, the second cohort included 58 patients who underwent PFC Total Knee replacement. All patients were under the care of one Consultant Orthopaedic Surgeon. Interestingly, the Kinemax Plus cohort was found to have a higher rate of revision as compared to the PFC cohort. A detailed comparison was then carried out between the two groups to identify any obvious cause for the disparity. The two cohorts were found to be well matched with respect to age, sex, ASA grade, underlying pathology and operative technique. Median follow up being 6 years and 5 years for the Kinemax and PFC groups respectively. There were 11 failed prostheses in the kinemax cohort, 7 undergoing revision with the remaining 4 patients offered revision but unwilling have surgery. Wear of the polyethylene tibial insert was the most obvious finding at revision, present in six out of the 7 revisions. 97% of the Kinemax Plus Prostheses were intact at 5 years but by 8 years only 87% were intact. There were no revisions performed in the PFC cohort. Post operative x-ray analysis was undertaken to rule out prosthesis misalignment as a cause for the increased failure rate. The coronal alignment of the prostheses (CAK) was calculated and all post operative x-rays were within the normal limits of 4–10 degrees. Analysis of the explanted Kinemax Plus polyethylene liners was undertaken. In six cases, the polyethylene bearing surfaces displayed severe surface and subsurface delamination at both medial and lateral sides. This suggests massive fatigue and fatigue wear. Only one inplant showed localised delamination. The surface characterisation suggests the hypothesis of weak UHMWPE particle interface strength.
We report the results of a prospective randomised controlled clinical trial assessing the radiosterophotogrametric analysis (RSA), clinical and radiological performance of a metal backed and an all-polyethylene tibial cruciate retaining, condylar design, PFC-TKA up to twenty four months. 65 patients were recruited, of which 41 patients were randomised. There were 20 metal backed and 21 all-polyethylene. None were lost to follow-up. There were no significant inter-group demographic differences. We found a significant increase in SF-12 and Oxford knee scores after surgery in both groups. No significant difference was found between the groups in the RSA, SF-12, Oxford Knee score, radiological alignment and range of movement at 6, 12 or 24 months. At 2 years one metal backed implant showed translational migration >
1mm. No all polyethylene implant migrated >
1mm. Further analysis identified possible progressive subsidence of the metal backed implants compared to all-polyethylene implants, although the magnitude of this difference was very small. We conclude that in the uncomplicated primary total knee arthroplasty, all polyethylene PFC-_ tibial prostheses had equivalent performance to the metal backed counterpart, using RSA as the primary assessment instrument at 24 months. We found no differences between the two designs as assessed by the secondary instruments: SF-12, Oxford knee score, alignment and range of movement at 24 months. Should half of all primary total knee replacements performed in the UK receive an all-polyethylene tibial implant, the estimated annual cost saving would be 21 million pounds per annum.
The aim of this longitudinal study is to compare the clinical outcomes of endoscopic ACL reconstruction with either a 4-strand HT or PT autograft over a 5-year period. 90 patients with isolated ACL rupture received PT autograft and 90 received HT autograft were studied annually for 5 years. Assessment included the IKDC Knee Ligament Evaluation, KT1000, Lysholm Knee Score, thigh atrophy, kneeling pain, hamstring pain and radiographs. The median Lysholm Knee Score was 96 for the PT group and 95 for the HT group. No significant difference was found for subjective knee function, overall IKDC assessment, Xray findings, manual ligament KT1000 instrumented testing, graft rupture or contralateral ACL rupture. There was an increasing incidence of fixed flex-ion deformity seen in the PT group. There was no difference in the requirement for subsequent surgery. The incidence of kneeling pain at 5 years was significantly higher in the PT group. Endoscopic reconstruction of the ACL utilizing either autograft can restore knee stability and is menisco protective despite a high level of sporting activity. We did find a worrying trend towards an increasing incidence of fixed flexion deformity with time in the patellar tendon group. Kneeling pain also remains a persistent problem in this subgroup.