Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 92 - 92
1 Sep 2012
Verdonk P Beekman P De Coninck T Verdonk R Raat F
Full Access

Purpose

to evaluate the kinematics of a knee with a polyurethane meniscal scaffold for partial meniscus defect substitution during flexion under weightbearing conditions in an upright MRI. In addition, radial displacement and the surface of the scaffold was compared to the normal meniscus.

Materials and Methods

One cadaver with a normal lateral meniscus and medial scaffold in the left knee and with a normal medial meniscus and lateral scaffold in the right knee. The scaffolds were implanted to substitute a 3 cm meniscus defect in the posterior horn. The cadaver was scanned in an 0,7T open MRI with a range of motion from 0-30-60-90 to hyperflexion. Kinematics were evaluated on sagittal images by the following two parameters: the position of the femoral condyle, identified by the centre of its posterior circular surface, which is named the flexion facet centre (FFC), and the point of closest approximation between the femoral and tibial subchondral plates, the contact point (CP). Both were identified in relation to the posterior tibial cortex.

The displacement, measured on coronal images, is defined as the distance between the tibial plateau and the outer edge of the meniscus. The surface was also measured on coronal slices and contains the triangular surface of the meniscus.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 489 - 489
1 Sep 2012
Stulberg B Covall D Mabrey J Burstein A Angibaud L Smith K Zadzilka J
Full Access

Introduction

While clinically successful for decades, CR TKA is persistently compromised by inconsistent PCL function. Problems of mid-flexion instability, incomplete knee flexion, erratic kinematic behavior and posterior instability, not seen with PS devices, raise concerns about the consistency of the technique, and the devices used. Most TKA systems offer at least 2 different geometries of tibial inserts to address this clinical problem.

We hypothesize these problems are a result of compromise of PCL anatomy. To avoid compromise to the PCL 3 steps are required: 1) The slope of tibial resection must be less than 5°; 2) the depth of tibial resection must be based off the insertion footprint of the PCL, not the deficiencies of the tibial articular surface; and 3) the tibial insert must be modified to allow intraoperative balancing of the PCL.

Results

The CR Slope ™ implants and technique (Exactech) (“Posterior Cruciate Referencing Technique (PCRT)”) reflect this philosophy and have allowed consistent surgical intervention without PCL release and without multiple inserts. We present data identifying, the footprint, and the instrument and technique modifications that allow for predictable identification of the depth and angle of resection. At 2 years post implantation in the first 100 patients implanted, the study group has demonstrated similar operative time, LOS and Oxford knee scores (OKS), while ROM averaged 5° greater, and time to achieved flexion was decreased.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 490 - 490
1 Sep 2012
Confalonieri N Manzotti A
Full Access

Introduction

The authors performed a short term prospective study of unicompartmental knee replacement (UKR) associated to patella-femoral arthroplasty (PFA) for the treatment of bicompartmental symptomatic knee arthritis. At the latest follow-up all the implants were matched to a similar computer assisted Total Knee Replacements (CAS-TKR) group implanted for the same indications. Hypothesis of the study was that this bicompartimental implants could achieve comparable outcomes to TKR with a more conservative surgery and a higher joint function.

Materials and Methods

19 cases of anteriomedial (12) or anterolateral (7) arthritis in 19 stable knees were prospectively involved in the study. All the knees underwent to a selective reconstruction using simultaneously both UKR and PFR using the same surgical technique. All bicompartmental implants were performed by the same surgeon. Surgical time, hospital staying and all intra and post operative complications were registered. At a minimum follow-up of 20 months, every single case was marched to a similar case where had been implanted a computer assisted cruciate retaining TKR. Criteria of matching were: sex, age, pre-operative range of motion and arthritis grade. In both the groups all the cases were assessed clinically using WOMAC, KKS and GIUM scores. All the knees were radiologically investigated using the same radiological protocol.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 491 - 491
1 Sep 2012
Rasmussen S Knudsen C Skou S Gronbech M Olesen J Rathleff M
Full Access

Introduction

Delayed onset muscle soreness (DOMS) in the quadriceps is frequent in runners finishing a marathon race, and may result in several days of discomfort and pain. There is an increasing clinical evidence that noninvasive, pulsed electromagnetic field therapy (PEMF) can have physiological effect on inflammation and tissue repair. The purpose of this pilot study was to investigate the effect of PEMF on quadriceps muscle soreness in marathon runners and to use the data to calculate an appropriate sample size for a subsequent study.

Material and methods

The design was a randomized double-blind prospective study covering a 5 days period after completion of a beach marathon. After the marathon all 74 runners that completed the 42.195 km were asked to participate in the study. Forty-six agreed to enter the study and were block randomized into an intervention group or a control group. The intervention group received an active pulsed electromagnetic field device, and the control group received a sham device. The sham devices were used in exactly the same manner but produced no electromagnetic field. The active PEMF device does not produce heat or cause any sensation in the tissue allowing participants to be blinded to treatment. The pulsed electromagnetic field signals of a 2-msec burst of 27.12-MHz sinusoidal waves were repeated at two bursts per second. Peak magnetic field was 0.05 G, which induced an average electric field of 10 mV/cm in the tissue with an effect of 7.3 mW/cm3. All subjects were instructed to place the device on the most painful area of the quadriceps for 20 minutes four times a day. Pain intensity was measured three times a day with the Visual Analogue Scale (VAS) during a 90o squat with a self-administered questionnaire. Data were non-parametric and compared with a two-sample Wilcoxon rank-sum test.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 299 - 299
1 Sep 2012
Clauss M Frunz S Pannhorst S Arteschrang A Ilchmann T
Full Access

Introduction

Primary stability of the Burch-Schneider ring (BSR) in case of acetabular revision is discussed controversial. In a retrospective two centre cohort study we analyzed the influence of the mode of screw fixation and the restoration of the center of rotation on migration, loosening and other radiographic parameters.

Material/Methods

Patients with a minimal radiographical follow-up of 2 years and suitable for EBRA analysis were included. In group 1 (46 patients) screws were placed through the cranial spherical part of the ring and covered by cement and cup, in group 2 (40 patients) screws were placed through the cranial flange. Preoperative bone defects were classified, the postoperative centre of rotation was determined. Changes of screws were recorded, migration exceeding >1mm was seen as significant.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 30 - 30
1 Sep 2012
Vinje T Fevang J Engesaeter L Lie S Havelin L Matre K Gjertsen J Furnes O
Full Access

Background

A well conducted randomised study found similar functional results for patients with displaced femoral neck fracture comparing operation with a modern uncemented bipolar hemiarthroplasty with a cemented bipolar hemiarthroplasty. The mortality associated with the two procedures has not been sufficiently investigated.

Aim of study

To investigate the mortality and the risk factors for death among patients with displaced femoral neck fractures the first year after surgery, comparing operation with modern uncemented and cemented bipolar hemiarthroplasty (HA).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 194 - 194
1 Sep 2012
Van Laarhoven S Bolink S Heyligers I Grimm B
Full Access

Introduction

Our classic outcome scores increasingly fail to distinguish interventions or to reflect rising patient demands. Scores are subjective, have a low ceiling and score pain rather than function. Objective functional assessment tools for routine clinical use are required. This study validates inertial sensor motion analysis (IMA) by differentiating patients with knee versus hip osteoarthritis in a block-step test.

Methods

Step up and down from a block (h=20cm, 3 repetitions) loading the affected (A) and unaffected (UA) leg was measured in n=59 subjects using a small inertial sensor (3D gyro and accelerometer, m=39g) attached onto the sacrum. Patients indicated for either primary unilateral THA (n=20; m/f=4/6, age=69.4yrs ±9.8) or TKA (n=16;m/f=7/9;age=67.8yrs ±8.2) were compared to healthy controls (n=23;m/f=13/10;age=61.7yrs ±6.2) and between each other to validate the test's capacity for diagnostics and as an outcome measure.

The motion parameters derived (semi-) automatically in Matlab for both legs were: front-back (FB-) sway and left-right (LR-) sway (up and down); peak-to-peak accelerations (Acc) during step down. In addition the asymmetry between both legs (ASS) was calculated for each parameter. Group differences were tested (t-test) and the diagnostic value determined by the area under the curve (AUC) of the ROC-curve.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 96 - 96
1 Sep 2012
Chuter G Ramaskandhan J Soomro T Siddique M
Full Access

Background

The recommended indications for total ankle replacement (TAR) are limited, leaving fusion as the only definitive alternative. As longer-term clinical results become more promising, should we be broadening our indications for TAR?

Materials and Methods

Our single-centre series has 133 Mobility TARs with 3–48 months' follow-up. 16 patients were excluded who were part of a separate RCT. The series was divided into two groups. ‘Ideal’ patients had all of the following criteria: age >60y, BMI <30, varus/valgus talar tilt <10°, not diabetic, not Charcot, not post-traumatic. The ‘Not ideal’ group contained those who did not fit any single criteria. We compared complications and outcome scores between both groups.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 395 - 395
1 Sep 2012
Sánchez Ruas JJ Burgos Flores J Aranda Romero F Del Olmo Hernández T De Blas G Barrios C Hevia E Regidor I Correa Gorospe C Ruíz Ibán M Díaz Heredia J López Mondéjar J Berrendero L
Full Access

Introduction

A new triggered electromyography test for detection of stimulus diffusion to intercostal muscles of the contralateral side during thoracic pedicle screw placement was evaluated. Experimental research was carried out in order to determine if, using this test, neural contact at different aspects of the spinal cord and nerve roots could be discriminated.

Methods

Nine industrial pigs (60–75 kg) had 108 pedicle screws placed bilaterally in the thoracic spine (T8–T13). Neural structures were stimulated under direct vision at different anatomic locations from T9 to T12. Recording electrodes were placed over the right and left intercostal muscles. Increasing intensity of the stimulus was applied until muscle response was detected at the contralateral side (diffusion phenomenon). After this first experiment, the thoracic spine was instrumented. Screws were placed in the pedicle in two different positions, the anatomic intrapedicular location and with purposeful contact with the neural elements.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 31 - 31
1 Sep 2012
Gjertsen J Vinje T Fevang J Lie SA Furnes O Havelin LI Engesaeter LB
Full Access

Introduction

Displaced femoral neck fractures in elderly are normally treated with 2 screws/pins (IF) or bipolar hemiarthroplasty (HA). The aim of this study was to compare IF and HA as treatment for displaced femoral neck fractures using reoperations and functional result (patient satisfaction, pain, and quality of life) as outcome.

Material and Methods

From January 2005 all hip fractures in Norway are reported to the Norwegian Hip Fracture Register. At 4, 12, and 36 months postoperatively a questionnaire assessing satisfaction (VAS 0-100), pain (VAS 0-100), and quality of life (EQ-5D) is sent to the patients. To ensure more than 3 years follow-up, only patients operated in 2005 were included in the present study. Consequently 1,968 patients over 70 years of age operated with IF (n = 958) or HA (n = 1,010) due to displaced femoral neck fractures were included in the analyses on reoperations. Of these, 280 patients responded to all questionnaires and were included in the analyses on functional results (IF: n = 135, HA: n = 145). The patients remained in the same treatment group according to the intention-to-treat principle.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 97 - 97
1 Sep 2012
Brorson S Frich LH Winther A Hrobjartsson A
Full Access

Introduction

There is considerable uncertainty about the optimal treatment of displaced four-part fractures of the proximal humerus. Within the last decade locking plate technology has been considered a breakthrough in the treatment of these complex injuries.

Methods

We systematically identified and reviewed clinical studies of the benefits and harms after osteosynthesis with locking plates in displaced four-part fractures.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 535 - 535
1 Sep 2012
Karuppaiah K Nanda R Stothard J Balasubramaniam S
Full Access

Introduction

The role of in-situ decompression in patients with severe ulnar nerve compression is still controversial. The authors present a prospective study on the results of in-situ decompression in this selected group of patients treated through a mini open incision (4cms) and complete decompression by appropriate patient positioning.

Material/Methods

Thirty patients (20 Male/10 Female) with severe degree of nerve compression, confirmed clinically by Dellon's classification and by abnormal Nerve Conduction Study, underwent simple in-situ decompression under general anaesthesia as a day-case procedure. Through a 4cms incision and by moving the elbow the nerve is fully visualised and decompressed.

Outcome was measured prospectively at three months and one year using Modified Bishop's score, grip strengths and two point discrimination (2PD).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 233 - 233
1 Sep 2012
Van Bergen C Tuijthof G Blankevoort L Maas M Kerkhoffs G Van Dijk C
Full Access

PURPOSE

Osteochondral talar defects (OCDs) are sometimes located so far posteriorly that they may not be accessible by anterior arthroscopy, even with the ankle joint in full plantar flexion, because the talar dome is covered by the tibial plafond. It was hypothesized that computed tomography (CT) of the ankle in full plantar flexion could be useful for preoperative planning. The dual purpose of this study was, firstly, to test whether CT of the ankle joint in full plantar flexion is a reliable tool for the preoperative planning of anterior ankle arthroscopy for OCDs, and, secondly, to determine the area of the talar dome that can be reached by anterior ankle arthroscopy.

METHODS

In this prospective study, CT-scans with sagittal reconstructions were made of 46 consecutive patients with their affected ankle in full plantar flexion. In the first 20, the distance between the anterior border of the OCD and the anterior tibial plafond was measured both on the scans and during anterior ankle arthroscopy as the gold standard. Intra- and interobserver reliability of CT as well as agreement between CT and arthroscopy were assessed by intraclass correlation coefficients (ICCs) and a Bland and Altman graph. Next, the anterior and posterior borders of the talar dome as well as the anterior tibial plafond were marked on all 46 scans. Using a specially written computer routine, the anterior proportion of the talar dome not covered by the tibial plafond was calculated, both lateral and medial, indicating the accessible area.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 137 - 137
1 Sep 2012
Allam A
Full Access

Background

In poliomyelitis; hand to knee gait is the sum of quadriceps weakness and fixed knee flexion deformity. Limb shortening is another added problem. Usually, each problem is attacked separately; with variable end results and complication rates for each procedure.

Patients and methods

22 patients (16–46 y.); with poliomyelitis with hand to knee gait due to fixed knee flexion deformity of mild to moderate degree (10–400); and limb shortening of 4.5–9.5 cm., were managed simultaneously by a single operation. A distal femoral metaphyseal anterior closing wedge (recurvatum) corrective osteotomy was done to treat acutely the fixed knee flexion deformity(and subsequently hand to knee gait). A modified Wagner or Orthofix frame was applied as a mono-plane mono-axial lengthening device to stabilize the osteotomy and to lengthen the short limb. Lengthening was started in all cases two weeks post-operatively.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 536 - 536
1 Sep 2012
Park IS Jung KA Ong A Hwang SH Nam CH Lee DW
Full Access

Background

Adequate rotation of femoral component in total knee arthroplasty(TKR) is mandatory for preventing numerous adverse sequelae. The transepicondylar axis has been a well-accepted reference for femoral component rotation in the measured resection technique. In this technique, measured resection is performed referenced off the tibial cut - perpendicular to the tibial mechanical axis with the knee in 90 ° of flexion. However, to the best of our knowledge, it is not known whether this technique apply well to a knee with tibia vara. This study evaluates the reliability of the transepicondylar axis as a rotational landmark in knees with tibia vara.

Methods

We selected 101 osteoarthritis knees in 84 symptomatic patients(mean age: 69.24 ± 5.68) with proximal tibia vara (Group A). Group A was compared with 150 osteoarthritic knees without tibia vara in 122 symptomatic patients (mean age: 69.51 ± 6.01) (Group B). The guide line for selection of all these knees were based on the degree of tibia vara angle (TVA) which was formed by line perpendicular to epiphysis and by anatomical axis of the tibia - all measured in radiographs of the entire lower limb. Magnetic resonance imaging (MRI) axial images with most prominent part of both femoral condyles were used for measurement of transepicondylar axis(TE), anteroposterior axis(AP) and posterior condylar axis(PC).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 234 - 234
1 Sep 2012
Van Bergen C Reilingh M Van Dijk C
Full Access

Objectives

Osteochondral ankle defects (OCDs) mainly occur in a young, active population. In 63% of cases the defect is located on the medial talar dome. Arthroscopic debridement and microfracture is considered the primary treatment for defects up to 15 mm. To treat patients with a secondary OCD of the medial talar dome, a 15-mm diameter metal implant (HemiCAP ®) was developed. The set of 15 offset sizes was designed to correspond with the anatomy of various talar dome curvatures. Recently, two independent biomechanical cadaver studies were published, providing rationale for clinical use. The present study was undertaken to evaluate the clinical effectiveness and safety of the metal implantation technique for osteochondral lesions of the medial talar dome in a prospective study.

Material and methods

Since October 2007, twenty patients have been treated with the implant. Four patients who did not meet the inclusion criteria and four patients who had less than one-year follow-up at the time of writing were left out of this analysis. Twelve patients are reported with one year (n=8) or two years (n=4) follow-up. All patients had had one or two earlier operations without success. On preoperative CT-scanning, the mean lesion size was 16 × 11 (range, 9–26 × 8–14) mm. Outcome measures were: Numeric Rating Scale pain (NRS) at rest and when walking, Foot Ankle Outcome Score (FAOS), American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score, and clinical and radiographic complications. Data are presented as median and range. The Wilcoxon signed ranks test was used to calculate p-values.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 139 - 139
1 Sep 2012
Topolovec M Milosev I Coer A Bloebaum R
Full Access

Background

Wear particles are considered to be the major culprit for the aseptic loosening. Their characterization is thus crucial for the understanding of their bioreactivity and contribution to the development of aseptic loosening.

Methods

Metal wear debris particles were analyzed directly in periprosthetic tissue resins by scanning electron microscopy (SEM) combined with back-scattered electron imaging (BSE) and energy dispersive X-ray spectroscopy (EDS). Four groups of tissue samples retrieved at revision operations of loosened hip implants with different bearing surfaces (metal-on-metal, ceramic-on-polyethylene and metal-on-polyethylene), and different material of the femoral stem (Ti alloy, CoCrMo and polymer combined with stainless steel) were investigated. Tissue samples were first analyzed histologicaly. Sections from the same paraffin blocks were then carbon coated and analyzed using SEM/BSE/EDS method.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 437 - 437
1 Sep 2012
Kobbe P Hockertz I Sellei R Reilmann H Hockertz T
Full Access

Sacroiliac screw fixation is the method of choice for the definitive treatment of unstable posterior pelvic ring injuries; however this technique is demanding and associated with a high risk of iatrogenic neurovascular damage. We therefore evaluated the outcome, complications, surgical and fluoroscopy time for unstable posterior pelvic ring injuries managed with a transiliac locked compression plate.

23 patients were managed with a transiliac locked compression plate for unstable posterior pelvic injuries at a Level I Trauma Center. 21 patients were available for follow up after an average of 30 months and outcome evaluation was performed with the Pelvic Outcome Score, which is composed of a clinical, radiological, and social integration part.

The overall outcome for the pelvic outcome score was excellent in 47.6% (10 patients), good in 19% (4 patients), fair in 28.6% (6 patients) and poor in 4.8% (1 patient). 15 out of 21 patients (71.4%) returned to their normal life, 3 patients (14.3%) were limited at work, and 3 patients (14.3%) were not able to return to work due to their disabilities. The social status was unchanged to the preinjury status in 19 patients (90.5%). 13 patients (62%) stated no changes in spare time and sports activities; 4 patients (19%) had minor and another 4 patients (19%) had major restrictions. The average operation time was 101 min and intraoperative fluoroscopic time averaged 74.2 sec. No iatrogenic neurovascular injuries were observed.

Posterior percutaneous plate osteosynthesis may be a good alternative to sacral screw fixation because it is quick, safe, and associated with a good functional outcome.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 237 - 237
1 Sep 2012
Loughenbury P Owais A Taylor L Macfie J Andrews M
Full Access

Introduction

Obesity has been associated with higher complication rates and poorer outcomes following joint replacement surgery. Body mass index (BMI) is a simple index of body composition and forms part of preoperative assessment. It does not take into account the proportion of lean mass and body fat and can give a false impression of body composition in healthy manual workers. A more accurate measure of body composition is available using non-invasive bioimpedance methods. This study aims to identify whether BMI provides an accurate measure of body fat composition in patients awaiting lower limb arthroplasty surgery.

Methods

Consecutive patients attending for pre-assessment clinic prior to total knee and hip replacement surgery were examined. All patients had their BMI calculated and underwent bioimpedance testing using a bedside Bodystat 1500 scanner (Bodystat, UK).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 32 - 32
1 Sep 2012
Friedl W Wright J
Full Access

The avulsion fracture of the V-th metatarsal and Jones fractures often show delayed and non-union. The tension belt osteosynthesis shows often soft tissue problems due to the thin soft tisshe covering. A new minimal invasive method with the 3,5mm XXS nail and the clinical results are presented.

Percutaneously the fracture is reduced with a K-wire as a joy stick. This or if the direction needed is different a second K-wire as guide is introduced and with a canulated 3,5 mm drill the place for the nail is prepared. Proximal and distal to the fracture one threaded wire locking and fracture compression through the nail (proximal longitudinal holes) are performed.

77 patients with a XXS nail fixation of MT V fractures were treated from July 1999 to Jan.2006. Clinical and radiological re-examination at 1 to 6 years were performed. The AOFAS was 22 pre- and 96 postoperatively. No pseudarthrosis but in 53 patients implant removal was done in part due to local discomfort. This was strictly correlated to the length of the threaded wires to the bone surface. 95% reached pretrauma activity levels. Satisfaction was 9 from 10 points.

The XXS nails allow a percutaneous stable fixation of the avulsion and Jones fractures of the V-th metatarsus. The complication rate is low.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 397 - 397
1 Sep 2012
Sánchez Ruas JJ Burgos Flores J Aranda Romero F Del Olmo Hernández T Piza Vallespir G De Blas G Montes E Caballero García A Barriga Martín A Collazo J Hevia E Correa Gorospe C Barrios C
Full Access

Objectives

To determine the limits of spinal displacement before the onset of neurophysiological changes during spinal surgery. Assessing if the type of force applied or the section of the adjacent nerve roots increases the tolerance to displacement.

Methods

Experimental study in 21 domestic pigs. Three groups were established according to the displacing force applied to the cord: separation (group 1, n=7), root stump pull (group2, n=7) and torque (group3, n=7). Successive records of cord-to-cord motor evoked potential were obtained. The displacing force was removed immediately when neurophysiological changes observed. The experiment was repeated after sectioning the adjacent nerve roots.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 398 - 398
1 Sep 2012
Lozano Alvarez C Ramírez Valencia M Matamalas Adrover A Molina Ros A Garcia De Frutos AC Saló Bru G Lladó Blanch A Cáceres IPalou E
Full Access

Introduction

Chronic pain is one of the adverse outcomes in surgery for degenerative lumbar pathology (DLP). Postoperative complications as DVT, and chronic pain in pathologies as thoracotomy or breast cancer have been associated with poor control of postoperative pain.

Study design

Prospective study of patients undergoing surgery for DLP.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 101 - 101
1 Sep 2012
Maempel J Coathup M Calleja N Cannon S Briggs T Blunn G
Full Access

Background

Extendable proximal femoral replacements(PFR) are used in children with bone tumours in proximity to the proximal femoral physis, previously treated by hip disarticulation. Long-axis growth is preserved, allowing limb salvage. Since 1986, survival outcomes after limb salvage and amputation have been known to be equal.

Method

Retrospective review of all patients <16years undergoing extendable PFR at Royal National Orthopaedic Hospital (UK) between 04/1996 and 01/2006, recording complications, failures, procedures undertaken and patient outcomes.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 497 - 497
1 Sep 2012
Spalazzi J Baldini T Efird C Traub S Hiza E Cook S Rioux-Forker D Mccarty E
Full Access

Summary

Strong mechanical fixation is critical to the success of rotator cuff repairs. In this comparative study in cadaveric shoulders, single-tendon full-thickness supraspinatus tears were repaired using two different types of PEEK knotless suture anchors-ReelX STT (Stryker) and Opus Magnum PI (Arthrocare)-using a single-row technique in both instances. Cyclic testing was performed followed by loading until mechanical failure. No significant difference was observed in gap formation, measured as the distance between the supraspinatus tendon and bone at the repair site, during cyclic loading. However, the maximum load was statistically higher for repairs with the ReelX anchor.

Purpose

The objective of this study was to compare the gap formation during cyclic loading and maximum repair strength of single-row full thickness supraspinatus repairs performed using two different types of PEEK knotless suture anchors in a cadaveric model.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 399 - 399
1 Sep 2012
Lozano Alvarez C Ramírez Valencia M Matamalas Adrover A Molina Ros A Garcia De Frutos AC Saló Bru G Lladó Blanch A Cáceres IPalou E
Full Access

Introduction

An important number of factors affecting the outcome of surgical treatment have been identified, and these factors can affect the patient's selection for lumbar surgery.

Study Design

Retrospective study with data collected prospectively on patients undergoing surgery for degenerative lumbar pathology (DLP).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 499 - 499
1 Sep 2012
Bell S Young P Drury C Blyth M Jones B Mclean A
Full Access

Introduction

Total knee arthroplasty is an established and successful operation. In up to 10% of patients who undergo total knee arthroplasty continue to complain of pain [1]. Recently computerised tomography (CT) has been used to assess the rotational profile of both the tibial and femoral components in painful total knee arthroplasty.

Methods

We reviewed 56 painful total knee replacements and compared these to 59 pain free total knee replacements. Datum gathered from case notes and radiographs using a prospective orthopaedic database to identify patients. The age, sex, preoperative Oxford score and BMI, postoperative Oxford score and treatments recorded. The CT information recorded was limb alignment, tibial component rotation, femoral component rotation and combined rotation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 306 - 306
1 Sep 2012
Radulescu R Badila A Nutiu O Manolescu R Nita C Traian C Japie I Papuc A Radulescu D
Full Access

Aim

to compare the medium term clinical and functional results of total hip arthroplasty after intertrochanteric osteotomy and primary total hip replacement.

Material and methods

We compared 2 groups of patients: Group I-93 patients with total hip arthroplasty after intertrochanteric osteotomy and Group II-93 patients with primary total hip arthroplasty. The patients in the control group (Group II) were randomly chosen from the cases operated by the same surgical team using the same kind of implant like those in Group I. The osteotomies were of different types: medial displacement (27), varisation(19), valgisation (18), flexion(25), rotational (4). The demographic parameters were similar in the 2 groups. Technical intraoperative challenges were noted. The Harris Score was determined at 12 months and 3 years after surgery. Clinical and radiological check-ups were performed each year. The duration of each surgical procedure was recorded. Complications were noted during the entire follow-up. The mean follow-up was 77 months.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 307 - 307
1 Sep 2012
Majeed H Bishnoi A Howard P
Full Access

Introduction

There is no established evidence to support the use of drains after total knee replacement; however 94% of orthopaedic surgeons in UK routinely use closed suction drains. Haematomas can form with or without using drains, presence of which in addition may provide portal for infection and may increase blood loss. Blood group and save is routinely performed for every patient undergoing total knee replacement, however actual cross match and transfusion is needed for a small percentage of patients.

Aim

To compare the requirement for blood transfusion after total knee replacement with and without the use of closed suction drains and the cost analysis of performing routine blood group and save pre-operatively.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 402 - 402
1 Sep 2012
Pastides P El Sallakh S Charalambides C
Full Access

The aim of our study was to compare the clinical versus radiological diagnosis of patients suffering from a Morton's neuroma. Clinical assessments and pre operative radiological imaging of patients who underwent operative procedures for an excision of a Morton's neuroma were retrospectively compared. This review included 43 excised Morton's neuromas from 36 different patients over a period of 68 months, performed by one surgical team.

The commonest clinical symptoms were those of pain or tingling on the plantar aspect of the affected webspace on direct palpation (100%), pain of weight bearing (91%) which was relieved by rest (81%) and pain on stretching the toes (79%). The most sensitive clinical sign was a Mulder's click.

Our results showed that clinical assessment was the most sensitive method of diagnosing these neuromas (98%). All of our patients had at least one mode of radiological investigation. Ultrasonography was the commonest requested single imaging modality in our series. It was found to have a sensitivity of 90% (28/31). This imaging technique has the disadvantage of being operator dependant, as highlighted by the fact that one of our patients had a correct radiological diagnosis after a repeat ultrasound to the affected area was requested. Magnetic Resonance Image scan is a more expensive technique as it has the advantage of producing static reproducible images. As a single imaging modality, it was found to have a sensitivity of 92% (12/13) in our series. 3 patients had both imaging modalities; initial ultrasound failed to convincingly diagnose a neuroma in 2 cases and in the other case, the initial MRI did not show any pathology. In all these cases, the repeat imaging techniques confirmed the clinical diagnosis.

We conclude that there is no absolute requirement for ultrasonography or magnetic resonance imaging in patients who clinically are suspected to have a Morton's neuroma, as the clinical examination was found to be the most sensitive method of diagnosis. We suggest that the two main indications for performing some form of imaging is (a) an unclear clinical assessment and (b) cases when more than one webspace appears to be affected. An ultrasound of the webspaces should be the radiological investigation of choice, followed by a magnetic resonance scanning if any uncertainty still remains.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 308 - 308
1 Sep 2012
Lichte P Kobbe P Sellei R Knobe M Pape H
Full Access

Aim of the study

Aim of this study was to find out which factors influence the outcome after both column fractures of the acetabulum.

Methods

We performed a retrospective analyse of 115 patients with both column acetabular fractures. The period between the injury and follow-up ranges between 2 and 19 years, 5,7 years on average. The initial displacement, the presence of a dislocation of the hip and fractures of the femoral head were analyzed on the initial radiographs. Postoperative displacement was classified according the classification of Matta. The common classifications of Helfet (posttraumatic arthrosis), Ficat/Arlet (femur head necrosis) and Brooker (periarticular calcification) were used to radiologically classify the long term results. Statistics were performed by the Chi-square-test.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 106 - 106
1 Sep 2012
Xie J Wang Y Yang Z Zhang Y
Full Access

Introduction

To introduce a new classification method and analyze related risk factor about lateral wall perforation associated with lower cervical pedicle screw and free-hand insertion technique.

Methods

A Retrospective study was made to analyze 214 patients (1024 screws) with various cervical spine disorders, involved in pedicle screw instrumentation at C3-7 from July 2004 to July 2009. Researchers assessed the position of the screws in the pedicle by carefully probing intraoperatively and studying postoperative thin-slice computed tomography scan. Perforation of lateral wall was classified into two phases. Phase I refers to the burst of the pedicle by screw, which means that the length of screw threads penetrating the external cortex of pedicles on CT scan is 2 mm, whereas in Phase, the length is >2 mm. The Penetrated screws and related factors were analyzed though Backward Stepwise (Wald) Logistic regression.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 204 - 204
1 Sep 2012
Zietz C Fritsche A Mittelmeier W Bader R
Full Access

The prevalent cause of implant failure after total joint replacement is aseptic loosening caused by wear debris. Improvement of the wear behaviour of the articulating bearing between the cup and femoral head is essential for increased survival rate of artificial hip joints. Cross-linking of the polyethylene (PE) material is one attempt to reduce wear particle release at the articulating surface. Various cross-linked polyethylenes (X-PE) are used in orthopaedics since several years.

In total hip arthroplasty (THA) the use of larger femoral head sizes has specific reasons. Larger heads lead to a decreased risk of total hip dislocation and impingement as well as an improved range of motion in comparison to smaller head sizes like 28mm or less. However, the increasing diameter of femoral head can be associated with lower thickness of the PE liner and increased wear rate. Cross-linking of PE can improve the wear rate of the liner and hence supports the use of larger femoral heads. The aim of this experimental study was to evaluate the wear of standard vs. sequential X-PE (X3-PE) liner in combination with different ceramic femoral head sizes.

Wear testing was performed for 5 million load cycles using standard UHMW-PE liners (N2Vac) and X3-PE liners (each Stryker GmbH & Co. KG, Duisburg, Germany) combined with 28mm ceramic ball heads and the Trident PSL acetabular cup (Stryker). Furthermore, X3-PE liners with an internal diameter of 36mm and 44mm and decreased wall thickness (5.9mm and 3.8mm) were combined with corresponding ceramic heads. An eight station hip wear simulator according to ISO 14242 (EndoLab GmbH, Rosenheim, Germany) was used to carry out the standard wear tests. The tests were realised in temperature-controlled chambers at 37°C containing calf serum (protein content 20g/l).

The average gravimetrical wear rates of the standard UHMW-PE (N2Vac) liners combined with 28mm ceramic heads amounted to 12.6 ± 0.8mg/million cycles. Wear of X3-PE liners in combination with 28 mm ceramic heads was not detectable. The average gravimetrical wear rates of the X3-PE liners in combination with 36mm and 44mm ceramic heads amounted to 2.0 ± 0.5mg and 3.1 ± 0.3mg/million cycles, respectively.

The purpose of this study was to evaluate the effect of femoral head size at THA on standard and sequential X-PE liner. The wear simulator tests showed that the wear rate of PE liners with small heads (28mm) decreased by cross-linking of the PE significantly. The amount of wear at X-PE increased slightly with larger head size (36mm and 44mm). However, by sequential cross-linking, the wear rate using thinner liners and larger femoral heads is reduced to a fractional amount of wear at conventional UHMW-PE. Hence, the above-mentioned advantages of larger femoral head diameters can be realised by improved wear behaviour of sequential X-PE.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 310 - 310
1 Sep 2012
Savadkoohi D Siavashi B Rezanezhad SS Seifi M Savadkoohi M
Full Access

Aim

To analyse our results after en-block resection of aggressive GCT during 20 years period.

Methods

We review 86 patients with skeletal GCT during the last 20 years, from 1990 until 2009, retrospectively. In the cases of latent and active type, extended curettage and bone graft or cement were our treatment of choice, while in aggressive ones we performed en block resection and reconstruction by fibular autograft (e.g. in distal part of radius) or fusion/hinge joint prosthesis (e.g. in GCT around the knee joint). We describe the recurrences, metastases and complications according to treatment.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 205 - 205
1 Sep 2012
Beazley J Foguet P Prakash U Baxter J Krikler S
Full Access

Introduction

Metal on metal hip resurfacing (MMHR) has been advocated for the younger patient for several reasons including for the preservation of bone stock and ease of revision to total hip replacement (THR), thus ‘buying an additional operation’ for the patient. This rationale however assumes a good functional outcome after the revision to a THR and that the results of the ‘revision primary’ will not be compromised by the resurfacing which preceded it. We present our data on a consecutive series of 68 revised MMHRs.

Methods

Between September 1997 and September 2009, 927 consecutive patients underwent a hip resurfacing procedure performed by one of three senior surgeons at our institution. The Cormet resurfacing system was used for all patients. Sixty-eight of these patients had their resurfacing revised. Oxford hip score (OHS) obtained at a minimum of 12 months follow-up was used as the primary outcome measure.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 206 - 206
1 Sep 2012
Zietz C Fritsche A Lange R Mittelmeier W Bader R
Full Access

Due to increased life expectancy of human population, the amount of total knee replacements (TKR) is expected to increase. TKR reached a high grade of quality and safety, but most often it fail because of aseptic implant loosening caused by polyethylene (PE) wear debris. Wear is generated at the articulating surfaces, e.g. caused by three body particles, like bone fragments or bone cement particles. The aim of this experimental study was to compare the wear of tibial PE inserts combined with metallic and ceramic femoral components at three body wear situation induced by polymethylmethacrylate (PMMA) and zirconia (ZrO2) particles from the bone cement.

Wear testing was performed for 5 Mio load cycles, using tibial standard PE inserts combined with the same CR femoral component, in two different materials, Cobalt Chromium (CoCrMo) and Biolox delta ® ceramic (Multigen Plus Knee System, Lima Corporate, Italy). A knee wear simulator, according to ISO 14243 (EndoLab GmbH, Rosenheim, Germany), was used to carry out the tests. The tests were performed in temperature-controlled test chambers at 37 °C, containing calf serum with a protein content of 30 g/l. Polymethylmethacrylate (PMMA) and zirconia (ZrO2) bone cement particles (Palacos R ®) were manufactured to a size of 30 μm. The three body particles were added at all stations onto the articulating surface of the tibial PE insert (7mg per condyle) at every 500,000 cycles. Wear was determined gravimetrically and the surfaces of tibial inserts were analysed by scanning electron microscope (SEM) after finishing the 5 million cycles. Furthermore, roughness of the PE insert surfaces and the articulating surfaces of the different femoral components were detected and the PE wear particles were analysed by SEM.

The average gravimetrical wear rates of the tibial PE inserts in combination with CoCr and Biolox delta ® ceramic femoral components amounted to 6.4 ± 0.9 mg and 2.6 ± 0.4 mg per million cycles, respectively. Beside bone cement particles on the articulating surface of the PE inserts, polished surfaces and scratches were detected by SEM. In comparison to the untreated surfaces of the PE inserts at both material pairings the surface roughness at the articulating areas showed deep scratches and polished regions. Analyses of the metallic femoral components showed scratches at the articulating surfaces, none on ceramics.

The present study pointed out the effect of femoral component material in an abrasive three body wear situation on the wear properties of TKR. The wear simulator tests showed that wear of PE inserts under three body wear conditions, in combination with ceramic femoral components, was significantly lower than with metallic femoral components. With regard to anti-allergic properties, ceramic femoral components are promising products for TKR.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 505 - 505
1 Sep 2012
Wall A Wall A Hassan S Charalambous C
Full Access

Approximately 30000 total knee replacements are performed annually in the UK. Standard practice is to obtain a radiograph during the initial post-operative period. We performed a retrospective review of 638 total knee replacements and found no significant complications were visible on post-operative radiographs. There were 4 cases of mild femoral notching. Cessation of initial radiographs could save the NHS two million pounds annually. We suggest check radiographs in the initial post-operative period are unnecessary and waste valuable resources which could be distributed elsewhere.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 123 - 123
1 Sep 2012
Dhollander A Verdonk P Verdonk R Verbruggen G Almqvist K
Full Access

Aim

The present study was designed to evaluate the implantation of alginate beads containing human mature allogenic chondrocytes for the treatment of symptomatic cartilage defects in the knee.

Methods

A biodegradable, alginate-based biocompatible scaffold containing human mature allogenic chondrocytes was used for the treatment of chondral and osteochondral lesions in the knee. Twenty-one patients were clinically prospectively evaluated with use of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and a Visual Analogue Scale (VAS) for pain preoperatively and at 3, 6, 9, 12, 24 and 36 months of follow-up.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 420 - 420
1 Sep 2012
Oag H Daines M Nichols A Kiran A Arden N Carr A
Full Access

INTRODUCTION

This study describes the prevalence of pain, functional loss and rotator cuff tears (RCTs) in a general population cohort. It is the first multidisciplinary assessment in such a cohort.

METHODS

The Chingford cohort is a 19-year old longitudinal population study comprising 1003 women aged between 44 and 67 at baseline. To date 183 consecutive subjects (366) shoulders have been interviewed about their shoulders. Myometric strength assessment and high-definition ultrasound examination (US) have been performed on all shoulders. Additionally pain thresholds and perceptions of pain have been tested using quantitative sensory testing (QST) and a number of validated questionnaires, including the illness attitudes scale and the pain detect score.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 329 - 329
1 Sep 2012
Chauhan D Islam M Dharmarajan R
Full Access

About 81,000 total knee replacements are implanted in the United Kingdom annually. Conventionally pneumatic tourniquet and surgical drains have been used in total knee arthroplasty. However, no definite evidence or guidelines exist to support their use.

The present study aims to look for any difference in perioperative recovery and complications following use of pneumatic tourniquet and surgical drains in knee replacement surgery.

We retrospectively analysed 60 total knee arthroplasties performed by 3 different surgeons at our hospital during January 2007 to June 2010. A sample size of 20 patients in each group was evaluated. Group 1: used tourniquet and drain; Group 2: used tourniquet but no drain; Group 3: didn't use tourniquet but used drain. Data was collected and analysed using statistical means, t-test & analysis of variance.

Parameters compared were surgical (anaesthetic) time, mean postoperative haemoglobin at 24 hrs, blood transfusion rate, haematoma formation, wound infection, pain, deep vein thrombosis and infection at discharge. At 6 weeks clinical follow up letters were analysed.

Our results reveal that there is no significant difference in duration of surgery in either group. Use of tourniquets didn't improve on surgical time (123–133 minutes).

Our Local Hospital Pain Score was used (1 no pain, 2 mild, 3 moderate, 4 severe and 5 worst imaginable pain). No difference at discharge was seen in either group.

Similarly no difference was seen in either group with postoperative haematoma formation with one case (5%) in Group 1 and 3 respectively.

Although the immediate postoperative haemoglobin (Hb%) was comparable in all 3 groups, Group 3 patients received more blood transfusion compared to other groups based on clinical grounds. About 50 % of Group 3 needed blood transfusion compared to 10% in Group 1 and 5% in Group 2.

There was only one proven case of superficial infection at 6 weeks (Group 2) which responded well to antibiotics. There were 4 cases of cellulitis noted at 6 weeks (3 in Group 2 and 1 in Group 3) which responded to oral antibiotics. No deep infection was noted.

The mean hospital stay in hospital was 6.5 days in Group 1, 5.5 days in Group 2 and 8 days in Group 3. There was no difference in rate of post-operative deep vein thrombosis (5% in Group 1 and 3).

The present study with the use of tourniquet and surgical drain in total knee arthroplasty showed no significant difference in surgical time and incidence of postoperative haematoma, deep vein thrombosis. Pain score at discharge was comparable and so was the infection rate. Patients in Group 2 (used tourniquet but no surgical drain) had least hospital stay (mean 5.5 days) and least blood transfusion rate (5%). Decision to use pneumatic tourniquet & drain still lies with the operating surgeon. We recommend a randomised control study for further evidence.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 223 - 223
1 Sep 2012
Herrera L Loving L Essner A Nevelos J
Full Access

Osteolysis induced by UHMWPE debris has historically been one of the major causes of long term failure of TJR. An increase in concentration of polyethylene particles in the peri-prostheic tissue has been linked to an increased incidence of osteolysis. The dual mobility hip bearing concept mates a femoral head into a polyethylene liner which has an unconstrained articulation into a metal shell. The wear mechanism of the dual mobility hip bearing is distinct from a constrained single articulation design, which may result in a difference in wear debris particles. The aim of this study is to evaluate wear debris generated from a dual mobility hip and compare it to a conventional single articulation design when both are manufactured from sequentially crosslinked and annealed polyethylene. The dual mobility hip (Restoration ADM) incorporated a 28mm CoCr femoral head into a polyethylene liner that articulates against a metal shell (48mm ID). The conventional hip (Trident®) mated a 28mm CoCr femoral head against a polyethylene liner. The polyethylene for all liners was sequentially crosslinked and annealed (X3). A hip joint simulator was used for testing at a rate of 1 Hz with cyclic Paul curve physiologic loading. A serum sample from each testing group was collected. Serum samples were protein digested following the published process by Scott et al. The digested serum was then filtered through a series of polycarbonate filter papers of decreasing size and sputter coated with gold for analysis using SEM. Image fields were randomized and wear debris was compared in terms of its length, width, aspect ration, and equivalent circular diameter (ECD). A total of 149 conventional hip particles and 114 dual mobility hip particles were imaged. Results show a majority of particles are of spherical nature and images do not indicate the presence of fibrillar or larger elongated polyethylene debris. Particle length between designs is not statistically different, while all other comparisons show statistical significance (p<0.05). It is hypothesized that the dual mobility hip system reduces the total amount of cross-shear motion on any one articulation, which aids in the reduction in wear. This design feature may be responsible for the slight difference in morphology of dual mobility wear debris when compared to the constrained hip design. The length of the particles was similar, simply indicating a different shape rather than a marked reduction in overall size. The debris generated is this study was from highly crosslinked polyethylene in two different designs, which produced a very significant decrease in quantity of particles when compared to the quantity of debris from conventional polyethylene. The wear debris was of similar length in both designs and so we do not expect any difference in biological response to debris from either device. The dual mobility design has also shown no effect of cup abduction angle on wear demonstrating forgiveness to implant positioning. This advantage, combined with the low wear rate and similar length wear particles, should lead to good clinical performance of dual mobility cups with sequentially irradiated and annealed polyethylene.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 524 - 524
1 Sep 2012
Prasad K Hussain A
Full Access

We hypothesised that an independent Notch Trial is essential on the same lines as other Component Trials-Femoral, Tibial and Patellar - in posterior stabilised total knee arthroplasty. Therefore we evolved Notch Trial to visually ascertain the adequacy of intercondylar resection and eliminate the possibility of femoral intercondylar fractures. We undertook a retrospective study to evaluate Notch Trial by the frequency of the need to remove osteophytes or file uneven surfaces in intercondylar resection by using the detachable box part of the trial femoral component, assess occurrence of distal femoral intercondylar fractures and demonstrate Notch Trial in posterior stabilised total knee replacement.

We studied 206 patients, 113 females and 93 males, who underwent consecutive primary posterior stabilised total knee replacements applying Notch Trial between 2000 and 2008 in a District General Hospital under our team. Outcome Measurements were 1) frequency of the need to remove osteophytes or file uneven surfaces in intercondylar resection and 2) occurrence of distal femoral intercondylar fractures intraoperatively or on postoperative radiographs. We had to remove the osteophytes and file the cut surfaces in 183 (88.88%) of patients after Notch Trial. We had no distal femoral intercondylar fractures intraoperatively or on postoperative radiographs.

Notch Trial allows the surgeon to directly visualise and ascertain the adequacy and precise fit of femoral notch cut with cam part of femoral component to ensure a press fit femoral component in condylar posterior cruciate substituting total knee replacement. Notch Trial prior to Femoral Component Trial effectively pre-empts intraoperative distal femoral intercondylar fractures. We recommend that Notch Trial should become part of the protocol for cruciate substituting total knee replacement and implants of all companies should have the option of a detachable box component for Notch Trial.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 333 - 333
1 Sep 2012
Essig J Nourissat C Asencio G
Full Access

The use of a total hip arthroplasty with alumina on alumina bearing couple should limit the risk of wear and secondary osteolysis. From June 1999 to December 2002, we have realised a continuous series of 265 ABGII cementless THA with Alumina bearing.

The average age was 58 years (22–78 years). The main causes were osteoarthritis (81%) and osteonecrosis (13%). The operation was performed through a posterior standard approach. In all cases, an anatomic cementless ABG II stem and an acetabular cementless ABG II cup were implanted. The bearing couple was always Alumina Biolox Forte with a 28 mm femoral head in 99% of cases. To date, 12 patients died and 17 patients were lost to follow up (6.4%). 224 patients (232 hips) had a regular clinical and radiological follow-up. The mean follow up was 8.5 years (5–11 years). 9 patients were revised for septic loosening (4cases), femoral fracture (4 cases) and inveterate dislocation (1 case). There was no aseptic loosening. The overall survival rate at more than 10 years is 96.6%. We deplore 2 cases of postoperative dislocation. In this series, we did not observe any breakage of ceramic implant. The clinical and functional outcome is good and stable over time with an average PMA score at 17.6 and an average Harris score at 97.3. 16 patients reported at least one or more episode of abnormal noise “Squeaking” type (6%). It is most often a mild noise and it occurs in a static bending position. This noise disappeared with time in 10 cases. It never necessitated a prosthetic revision. The radiological control does not show any wear. There is no evidence of acetabular or femoral osteolysis. The radiological implant fixation according to the Engh and ARA criteria was good and stable in all cases.

This series demonstrate that the implantation of an anatomic cementless HA arthroplasty with an alumina bearing in a young and active patient prevents the risk of wear and osteolysis and improves durability over time. The use of a 28 mm head does not increase the risk of instability and we did not observe failure of the ceramic implants.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 132 - 132
1 Sep 2012
Milosev I Kovac S Trebse R Levasic V Topolovec M Pisot V
Full Access

Introduction

Alternative bearings – metal-on-metal and ceramic-on-ceramic bearings have been introduced in the last decade with the aim to diminish wear and, subsequently, aseptic loosening and osteolysis. These bearings were aimed for younger, more active patients. Clinical results which would compare the performance of various alternative and traditional bearings are scarce.

Methods

Between January 2000 and December 2002, we performed 487 total hip replacements in 474 patients using three types of bearings: metal-on-metal (MOM), metal-on-polyethylene (MOP), and ceramic-on-ceramic (COC). All patients received the same type of acetabular cup (Bicon-Plus, Plus Orthopedics) and same type of femoral component (SL-Plus, Plus Orthopedics). We used the hospital computer database for the evaluation of patient data and data on revision operations.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 532 - 532
1 Sep 2012
Raposo F Sousa A Valente L Duarte F Loureiro M Monteiro E São Simão R Moura Gonçalves A Pinto R
Full Access

Introduction

Interest in platelet-derived growth factors has been increasing as an adjunct in surgical techniques for tissue repair. Its use in ligament injuries repair has been studied mainly in animals. The authors intend to study growth factors influence in ACL repair using BTB graft.

Material

20 individuals underwent ACL rupture BTB arthroscopic repair, using Double Incision Mini-Invasive Technique. MRI (3-Tesla) images. GPSIII ® System to obtain Platelet-Rich Plasma (PRP) thrombin activated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 338 - 338
1 Sep 2012
Angibaud L Stulberg B Mabrey J Covall D Burstein A Steffens J Haider H
Full Access

Introduction

A tibial insert with choices in size, thickness, and posterior slope is proposed to improve ligament balancing in total knee arthroplasty. However, increasing posterior slope, or the angle between the distal and proximal insert surfaces, will redistribute ultra-high molecular weight polyethylene (UHMWPE) thickness in the sagittal plane, potentially affecting wear. This study used in-vitro testing to compare wear for a standard cruciate-retaining tibial insert (STD) and a corresponding 6° sloped insert (SLP), both manufactured from direct-compression molded (DCM) UHMWPE. Our hypothesis was slope variation would have no significant effect on wear.

Methods

Two of each insert (STD and SLP) were tested on an Instron-Stanmore knee simulator with a force-control regime. The gait cycle and other settings followed ISO 14243-1 and -2, except for reference positions. The STD insert was tilted 6° more than the SLP insert to level the articular surfaces. Wear was gravimetrically measured at intervals according to strict protocol.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 313 - 313
1 Sep 2012
Garg B Kotwal P
Full Access

Introduction

Scaphoid nonunions remain controversial with regard to optimal management. The objective of this article is to compare our clinical experience in the treatment of patients with scaphoid nonunion using distal radius non vascularised bone graft with that of iliac crest bone graft.

Material & Methods

We conducted a prospective randomized study comparing the clinical, functional and radiographic results of 42 patients treated for scaphoid nonunion using a non-vascularised bone graft from the dorsal and distal aspect of the radius (group I), relative to 46 patients treated by means of a conventional non-vascularised bone graft from the iliac crest (group II). All nonunions were stabilized with single Herbert screw.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 318 - 318
1 Sep 2012
Ruggieri P Pala E Angelini A Drago G Romantini M Romagnoli C Mavrogenis A Abati C Mercuri M
Full Access

Introduction

Dedifferentiated chondrosarcoma (D.C.) has a very poor prognosis. The efficacy of chemotherapy is still debated. Aim of this study was to evaluate the survival of patients with D.C. and to evaluate possible prognostic factors.

Methods

Between 1990 and 2006, 109 patients were treated for D.C.: 55 males and 54 females, mean age of 59.6 years. In 81 cases tumor was located in the extremities and in 28 cases in the trunk. The most frequent dedifferentiation was in osteosarcoma (53.2%) followed by spindle cell sarcoma (21%), malignant fibrous histiocytoma (13.8%), fibrosarcoma (6.4%). All patients received surgery and mostly, limb salvage with tumor resection and implantation of a megaprosthesis or allograft (65 patients). Chemotherapy was given to 43 patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 512 - 512
1 Sep 2012
Zlowodzki M Armitage B Wijdicks C Kregor P Bruce L Cole P
Full Access

Introduction

The most common treatment options for fixation of osteoporotic distal femur fractures are retrograde nails and locking plates. There are proponents of more elastic titanium plates as well as more rigid steel plates; No clear superiority of one over the other has been established. We aimed to evaluate the mechanical differences between stainless steel and titanium locking plates in the fixation of distal femur fractures in osteoporotic bone. We hypothesized that due to its higher elasticity titanium locking plates can absorb more energy and are therefore less likely to “cut” into the bone compared to stainless steel locking plates resulting in improved metaphyseal osteoporotic fracture fixation.

Methods

We used eight matched pairs of osteoporotic fresh-frozen human cadaveric femurs (age >70 years, all female). Within each pair we randomized one femur to be fitted with a Less Invasive Stabilization System (LISS-Titanium locking plate) and one with a Distal Locking Condylar Plate (DLCP-Stainless steel locking plate).

A fracture model simulating an AO 33-A3 fracture was created (extraarticular comminuted fracture) and specimens were subsequently subjected to step-wise cyclic axial loading to failure. We used an advanced three dimensional tracking system (Polhemus Fastrak) to monitor the movement of the distal fragment relative to the real time distal plate position allowing us to evaluate distal implant cut-out.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 322 - 322
1 Sep 2012
Bock P Pittermann M
Full Access

Background

Acquired flatfoot deformity goes ahead with a partial or complete rupture and thus insufficiency of the tibialis posterior tendon. We present the results of flexor digitorum longus transfer and medial displacement calcaneal osteotomy to reconstruct the acquired deformity.

Material & Methods

Twenty two patients (24 feet) with an average age of 58 (36–75) years were operated on for acquired flexible flatfoot deformity. Two patients had a bilateral procedure. Patients were seen pre-and postoperatively in order to evaluate following parameters: AOFAS hindfoot score, visual analogue scale for pain (0–10), the tarsometatarsal angle on lateral and ap standing x-rays, the cuneiform heights and talocalcaneal angle on lateral standing x-rays and subjective postoperative satisfaction score (1-worst to 5-best). Average time of follow-up was 24.7 months (12–48).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 515 - 515
1 Sep 2012
Atrey A Corbett S Gibb P Jahnich H Warshafsky J
Full Access

Accurate documentation of operative findings is a fundamentally important part of any procedure and forms part of the Royal College of Surgeons of England's guidelines to good care, especially to “ensure that there are legible operative notes (typed if possible) for every operative procedure.” However, many hospitals fall short of this guideline when it comes to arthroscopic procedures because of the difficulty in reproducing visually representative and easy-to-understand images. There is an inability to properly record and archive findings of arthroscopic procedures. We, along with the British Orthopaedic Association, have developed an interactive, free Web-based operative note template that allows the surgeon to draw findings on diagrams of the joints commonly undergoing arthroscopy, type the findings, and then print as many copies as required. The use of the forms has allowed for quicker, easier, and more accurate documentation of arthroscopic procedures. The forms can then be saved to a database and used as a research tool.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 216 - 216
1 Sep 2012
Ahmed I Clement N Tay W Porter D
Full Access

Background

Fractures of the scaphoid are uncommon in the paediatric population. Despite their rarity a significant number of children are referred to the fracture clinic for a suspected scaphoid fracture. The aim of this study is to report on the incidence and pattern of injury of the paediatric scaphoid fracture and present a new classification.

Methods

An analysis of all paediatric scaphoid fractures treated in the Royal Hospital for Sick Children, Edinburgh (age up to 14 years old) over a five year period. The case notes, radiographs and were applicable MRI scan for these patients were reviewed. The clinical information recorded included the dominant hand, mechanism of injury, clinical features on examination, type of cast and length of period, stiffness following cast removal and evidence of delayed or non union. Each radiograph was analysed independently and fracture classified according to a new classification system.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 517 - 517
1 Sep 2012
Samuelsson B Hellström P Al-Ani A Hedström M
Full Access

Background

Elderly patients with hip fractures are often malnourished and in a catabolic state upon admission to hospital. Waiting time for surgery is commonly unpredictable, and often more than 24 hours. Due to an assumed stress-induced delayed gastric emptying time with a possible associated risk of aspiration, fasting guidelines are the same as for other trauma patients. This leads to prolonged fasting time in these patients who are often metabolically compromised, with negative effects on post-operative recovery and prolonged hospital stay. The aim of this study was to investigate if 400 ml of a carbohydrate-rich beverage could be given to patients with a hip fracture 2–3 hours before surgery without carrying a risk of pulmonary aspiration.

Methods

The gastric emptying rate of 400 ml 12.6 % carbohydrate rich drink was investigated in ten elderly women with a hip fracture awaiting surgery. The emptying rate was assessed by an indirect method, the paracetamol absorption technique. Results were compared with two control groups of healthy persons.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 217 - 217
1 Sep 2012
Ahmed I Ashton F Elton R Robinson C
Full Access

Background

The functional outcome and risk of recurrence following arthroscopic stabilisation for recurrent anterior shoulder instability is poorly defined in large prospective outcome studies. This is the first study to prospectively evaluate these outcomes in patients who have been treated using this technique.

Methods

We performed a prospective study of a consecutive series of 302 patients (265 men and 37 women, mean age 26.4 years) who underwent 311 (9 bilateral) arthroscopic Bankart repairs for recurrent anterior instability. Patients were evaluated preoperatively and postoperatively at 6 months, and annually thereafter. The chief outcome measures were risk of recurrence and the two-year functional outcomes (assessed using the WOSI and DASH scores).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 418 - 418
1 Sep 2012
Goost H Karius T Deborre C Kabir K Randau T Burger C Wirtz D Pflugmacher R
Full Access

Introduction

Pedicle screw pullout or loosening is increased in the osteoporotic spine. Recent studies showed a significant increase of pullout forces especially for PMMA-augmentation. With application of conventional viscosity PMMA the risk of cement extravasation is associated. This risk can be reduced by using radiofrequency-responsive, ultrahigh viscosity bone cement.

Method

11 fresh-frozen lumbar vertebral bodies (VB) from 5 cadavers were collected and freed from soft-tissue and ligaments. By DEXA scan (Siemens QDR 2000) 8 VB were identified as severely osteoporotic (BMD 0.8 g/cm3), 3 VB were above this level. Two screws (6×45 mm, WSI-Expertise Inject, Peter Brehm, Weisendorf, Germany) were placed in the pedicles. Through the right screw 3ml of radiofrequency-responsive bone cement (StabiliT® ER2 Bone Cement, DFine, Germany) were injected via hydraulic cement delivery system (StabiliT® Vertebral Augmentation System, DFine, Germany). As control group, left pedicle screws remained uncemented. After potting the whole VB in technical PMMA (Technovit 4004, Heraeus Kulzer, Germany) axial pullout test was performed by a material testing device (Zwick-Roell, Zmart-Pro, Ulm, Germany).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 219 - 219
1 Sep 2012
Lawton R Singer B Ridley D
Full Access

Background

Metal on metal hip resurfacing has become popular worldwide for younger patients because of perceived advantages in function and ease of revision, due to bone conservation. Joint Registry data have shown increased risk of early failure, particularly in younger females. There have been few studies comparing the outcome of resurfacing to cemented total hip arthroplasty (THA).

Methods

715 Hip Resurfacings (HR) performed between 2000 and 2010 with up to 10 years follow-up were compared with 2210 Exeter cemented Total Hip Arthroplasties (THA) performed for all diagnoses during the same period within our region. Survivorship was recorded using revision for any cause as the end point. Harris Hip Scores were collected pre-operatively and at 1,3,5 and 7 year review. Prospective independent analysis was carried out using Kaplan Meier survivorship, and non-parametric testing to investigate the effect of age (under 55 and over 55) and gender on revision rate and Harris Hip Score.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 220 - 220
1 Sep 2012
Myriokefalitakis E Papanastasopoulos K Douma A Krithymos T Drougas T Giannoulias J Savidis K Agisilaou C Kateros K
Full Access

Background

The degree of postoperative pain is usually moderate to severe following Total Hip Arthroplasty (THA). Comfort and lack of pain are important for optimal mobilization and earlier home discharge.

Aim

To evaluate the efficacy and safety of Ropivacaine, a long- acting local anaesthetic, when infiltrated in the wound at the end of operation of THA.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 222 - 222
1 Sep 2012
Li C Hussain A Pamu J Kamali A
Full Access

INTRODUCTION

Hip wear simulator test results could be affected by many non-bearing related factors such as fixation surface conditions, equipment calibration and component set-up. In an effort to improve the accuracy, reliability and repeatability of hip simulator test, a quality management system has been established at the IDC hip tribology laboratory, which has been accredited by UKAS (United Kingdom Accreditation Service) in accordance with the recognised international standard ISO17025. This study demonstrates that under well-controlled laboratory and testing conditions, satisfactory repeatability can be achieved during hip simulator studies.

METHODS

Between 2008 to 2010, ten 50 mm Birmingham Hip Resurfacing (BHR) devices were tested by the IDC tribology laboratory using two ProSim hip wear simulators in three different tests (T1, T2 and T3). All tests were performed following the same IDC testing protocols at 1 Hz frequency for 5 million cycles (Mc) or until after a steady state was reached. Paul type stance phase loadings with a maximum load of 3 kN and a swing phase load of 0.3 kN was used. The flexion and extension angles were 30 and 15 degree. The internal/external rotation angel was ±10 degree. Wear was measured gravimetrically using an analytical balance (Mettler, Toledo xp504) with an accuracy of 0.1 mg.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 128 - 128
1 Sep 2012
Espié A Espié A Laffosse J Abid A De Gauzy JS
Full Access

Introduction

Sternoclavicular dislocations are well-known adult injuries. The same traumatism causes growth-plate fracture of the medial clavicle in children and young adults. At this location, the emergence of the secondary ossification center and its bony fusion are late. We report the results of 20 cases hospitalized in the Toulouse University Hospital Center that were treated surgically.

Materials & Methods

20 patients were treated between 1993 and 2007, 17 boys and 3 girls, 16 years old (6–20). The traumatism was always violent (rugby 75%). Two physeal fractures were anteriorly displaced, and 18 posteriorly. The follow-up is 64 month (8–174).

Clinical, radiographic and therapeutic characteristics were assessed. The long-term results were analysed with: an algo-functional scale (Oxford shoulder score), the subjective Constant score, a functional disability scale (Shoulder simple test), a quality of life scale (DASH), and global indicators (SANE and global satisfaction).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 88 - 88
1 Sep 2012
Seah M Robinson C
Full Access

Background

Proximal humeral fractures are common and a minority develop non-union, which can result in pain and disability. We aimed to identify the risk factors and quantify the prevalence of non-union.

Methods

A thirteen-year retrospective study of 7039 patients with proximal humeral fractures was performed and a database created. 246 patients with non-union were compared to a control group to identify risk factors. Logistic regression analyses were performed to identify significant variables obtained at presentation to predict non-union.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 294 - 294
1 Sep 2012
Correa E Miquel J Sara M Isart A Ignacio G Tapiolas J Càceres E
Full Access

Our aim is to evaluate life quality in patients with achondroplasia after lengthening.

We examined 17 patients (11 men and 6 women) who finished the complete lengthening process in the 3 segments (tibia, femur, humerus) more than 3 years ago. Mean age 30.35 years(17–44). And a final height of 152.3cm (140.4–169) with an increase in the size of the tibia of 15.38cm, femur 14.91cm and humerus 9.91cm

Life quality is assessed by the SF.36 test and a specific questionnaire for low size people.

The results show that the mental health component (52.2) and physical component (52.8) are similar to those of general American population. There is also a statistical correlation between the final height and better results on the Mental Health questions of SF.36 (p=0.013) and the psychological questions of the specific questionnaire (p=0.045).

Achondroplasic patients after lengthening have a standard life quality and the increase of their height improves the mental health aspects of life quality.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 465 - 465
1 Sep 2012
Cook A Howieson A Parker M
Full Access

Introduction

Debate still exists as to the optimum method of fixation for subtrochanteric femoral fractures. Meta-analysis of studies comparing cephalocondylic nails with extramedullary implants for extracapsular hip fractures have suggested that further investigation is required in this area. We present the outcome of the largest series to date of subtrochanteric fractures treated by both methods and with a minimum of one year follow-up.

Methods

244 patients with a subtrochanteric femur fracture were treated at one centre over a 21 year period were prospectively studied. 75 were treated with an extramedullary fixation implant and 168 with an intramedullary nail. Surviving patients were followed up till one year from injury.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 171 - 171
1 Sep 2012
Mirza S Tilley S Aarvold A Sampson M Culliford D Dunlop D
Full Access

Introduction

Controversy exists as to whether the short external rotator tendons and capsule of the hip should be repaired after posterior approach primary total hip arthroplasty (THA). Recent studies using radiopaque markers have demonstrated that reimplantation of these muscle tendons fail early and may not prevent post operative dislocation.

Methods

Using dynamic ultrasound examination we evaluated the patency of repair in 68 tendon groups (piriformis/conjoint tendon and obturator externus). We demonstrate short and medium term success in the reimplantation of these tendons using the double transosseous drill hole technique of reattaching the tendons and capsule to the greater trochanter. We followed up 21 of our total hip replacements and 13 hip resurfacings and undertook a dynamic ultrasound examination of the external rotators by an experienced musculoskeletal radiologist to assess their integrity at a minimum of 60 days and 100 days and an average of 213 days after the operation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 70 - 70
1 Sep 2012
Cazeneuve J Cazeneuve J Hassan Y Hilaneh A
Full Access

This clinical study analyzes the long-term outcomes and potential complications of the Grammont's reverse prosthesis in case of trauma in elderly population.

Between January 1993 and May 2010, thirty-seven consecutive patients with 26 three- and four-part fractures and 11 fracture-dislocations, mean age 75 (58 to 92) were evaluated with a mean follow-up of 7.3 years.

Eight complications occurred: 2 complex sympathetic dystrophies, 3 dislocations, 2 deep infections and one aseptic loosening of the base-plate leading to 3 re-operations and 2 prosthesis revisions. The mean Constant's score dropped from 55 at two year follow-up to 52 (20 to 84) at last revision because of an augmentation of the pain and a diminution of the strength which represented 67% of the mean score for the injured side. Mean modified Constant's score was 68. Only 58% were satisfied or very satisfied because of poor internal and external rotations avoiding nourishment with utensils, dressing and personal hygiene when the dominant side was involved.

Two complete glenoid borders, fourteen stable inferior spurs, twenty-one inferior scapular notches including ten of them with medial proximal humeral bone loss or radio lucent lines between the bone and the cement were observed. Notches were more important in size when the follow-up was longer. 62% of the patients had worrying images.

The crossing of the clinical and radiological data showed a degradation of the mean Constant's score (41) for pain and strength in cases of notches with troubling proximal humeral images. In spite of only one case of aseptic loosening at 12 year follow-up, results are disappointing and complications and revisions rates important. The functional result is never equal to the pre-broken state. New developments in design, bearing surfaces and surgical technique and a more long term results will refine the role of the reverse concept for fracture.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 272 - 272
1 Sep 2012
Rolfson O Salomonsson R Dahlberg L Garellick G
Full Access

This randomised methodological study sought to test the reliability of an Internet questionnaire and investigate the differences in response rates between traditional pen-and-paper questionnaires and Internet questionnaires for measuring patient-reported outcome after total hip arthroplasty (THA) surgery.

From the Swedish Hip Arthroplasty Register, 2 400 patients were chosen at random but stratified by age, sex and diagnosis for inclusion in a four-year follow-up using the health-related quality of life (HRQoL) tool EQ-5D and visual analogue scales for pain and satisfaction. The patients were randomized to answer the follow-up model protocol either via a password-protected Internet questionnaire or via a mailed pen-and-paper questionnaire.

A reliability test for the Internet follow-up instrument showed adequate correlation. However, the Internet group and the pen-and-paper group differed significantly (p<0.001) with a 92% response rate in the latter and 49% in the former. Adjusted to the normal age distribution of the THA population, the Internet response rate was 34%.

The patient-administered Internet questionnaire alone does not give a sufficient response rate in the THA population to replace the pen-and-paper questionnaire. However, the system is reliable and could be used for measuring patient- reported outcome if supplemented with traditional pen-and-paper questionnaires for Internet non-respondents. It is expected that this answer procedure will soon predominate in view of the general development of Internet functions. Register work may then become less resource-consuming and the results may be analysed in real time.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 369 - 369
1 Sep 2012
Rodriguez Vega V Cecilia D Suarez L Jorge A Auñon I Rojo M Blanco D Guimera V Bravo B Garcia L Resines C
Full Access

Introduction

Distal radius fractures are one of the most common injuries attended in hospitals. Throughout the years the treatment has change from simple cast to ORIF.

Objectives

To compare the functional and radiographic results in the treatment of the distal intrarticular radial fractures treated by volar buttress plate (T plate AO® Synthes, Oberdorf, Suiza) and fixed volar angle locking plate (DVR® Depuy, Warsaw, Indiana, USA).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 273 - 273
1 Sep 2012
Lazennec JY Rakover JP Aaron A Pascal Mousselard H Rousseau MA
Full Access

Introduction

Current artificial discs include 1 or 2 bearing surfaces, providing 3 or 5 degrees of freedom. The ESP® is a one-piece e implant made of silicon and polycarbonate -urethane securely fixed to titanium endplates. It allows limited rotation and translation with elastic return. This cushion without fixed rotation center achieves 6 degrees of freedom including shock absorption. This objective of this study was to evaluate the safety and efficacy of the concept in a prospective nonrandomized trial.

Material and methods

Prior to clinical implantations, the device was endurance tested at least 40 millions cycles. The polymer core weight and properties, the geometrical characteristics and cohesion of the implants remained stable.

A prospective trial was initiated in 2004 for L3L4, L4L5 and L5S1 levels. Total disc replacements have been performed in 153 lumbar levels through extra-peritoneal mini-invasive anterior approach with a minimum 2 years follow-up.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 274 - 274
1 Sep 2012
Morgan S Abdalla S Jarvis A
Full Access

Introduction

Trends in hallux valgus surgery continue to evolve. Basal metatarsal osteotomy theoretically provides the greatest correction, but is under-represented in the literature. This paper reports our early experience with a plate-fixed, opening- wedge basal osteotomy, combined with a new form of distal soft tissue correction (in preference to Akin phalangeal osteotomy).

Materials and Methods

Thirty-three patients are reported here. The basal metatarsal osteotomy is fixed with the ‘Low Profile’ Arthrex titanium plate. No bone graft or filler is required, providing the osteotomy is within about 12mm of the base.

Distal soft tissue correction comprised a full lateral release, and then proximal advancement of a complete capsular ‘sleeve’ on the medial side. The plate serves as a rigid anchoring point for the tensioning stitches. Using this technique, almost any degree of hallux valgus can be corrected, and there is even potential for over-correction.

Functional outcome was assessed using the Manchester-Oxford foot and ankle score (MOXF). Radiographically the intermetatarsal angle was evaluated pre-operatively and at least 6 months postoperatively. Patients’ satisfaction and complication rates were recorded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 372 - 372
1 Sep 2012
Bainbridge C Houston A Jones G Milner R Wilbrand S
Full Access

Introduction

In Europe, injectable collagenase clostridium histolyticum (CCH) is a novel, minimally invasive, non-surgical therapy with efficacy in correcting Dupuytren's contracture (DC). We evaluated the efficacy and tolerability of 5 CCH injections using a protocol designed to follow clinical practice.

Methods

This was a 20-center, 9-month, open-label study in which DC patients with primary flexion deformities 20° (100° for MP; 80° for PIP) received 3 CCH (0.58 mg) injections/joint (5 injections/patient) at 30-day intervals. The primary endpoint was clinical success, defined as a reduction in contracture to 5° 30 days after the last injection (“Day 30”). After first injection into a prioritized joint, patients opted to receive up to 2 more injections into the same cord or cords from other affected joints whether or not they achieved clinical success with the first joint. Adverse events (AEs) were monitored.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 9 - 9
1 Sep 2012
Gothesen O Espehaug B Havelin L Petursson G Furnes O
Full Access

Background

Improving positioning and alignment by the use of computer assisted surgery (CAS) might improve longevity and function in total knee replacements. This study evaluates the short term results of computer navigated knee replacements based on data from a national register.

Patients and Methods

Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005–2008, were evaluated. The five most common implants and the three most common navigation systems were selected. Cemented, uncemented and hybrid knees were included. With the risk for revision due to any cause as the primary end-point, 1465 computer navigated knee replacements (CAS) were evaluated against 8214 conventionally operated knee replacements (CON). Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous knee surgery, preoperative diagnosis and ASA category were used.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 278 - 278
1 Sep 2012
Aranganathan S Aranganathan S Lakkol S Taranu R Reddy G Friesem T Kang J
Full Access

Introduction

The implantation of DIAM in interspinous space is believed to act as facet joints and provides stability to operated segment by shifting instantaneous axis of rotation forward in lordotic disorders. In this retrospective study, the patients who underwent lumbar surgery with DIAM (Medtronic Sofamor, Danek) spacer implants were followed up with an aim to evaluate the clinical outcomes. To our knowledge, this is the largest series with longest follow up.

Material Methods

Patients who underwent lumbar surgery (discectomy and decompression) with concomitant placement of DIAM spacer within a 36-months period were included. A total of 52 patients including equal number of male (n=26) and female (n=26), were followed up for 12 to 45 months (Mean: 22 months).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 375 - 375
1 Sep 2012
Zaffagnini S Marcheggiani Muccioli GM Bonanzinga T Signorelli C Lopomo N Bignozzi S Bruni D Nitri M Bondi A Marcacci M
Full Access

INTRODUCTION

This study aimed to intra-operatively quantify the improvements in knee stability given both by anatomic double-bundle (ADB) and single-bundle with additional lateral plasty (SBLP) ACL reconstruction using a navigation system.

MATERIALS AND METHODS

We prospectively included 35 consecutive patients, with an isolated anterior cruciate ligament injury, that underwent both ADB and SBLP ACL reconstruction (15 ADB, 20 SBLP). The testing protocol included anterior/posterior displacement at 30° and 90° of flexion (AP30–AP90), internal/external rotation at 30° and 90° of flexion (IE 30–IE90) and varus/valgus test at 0° and 30° of flexion (VV0–VV30); pivot-shift (PS) test was used to determine dynamic laxity. The tests were manually performed before and after the ACL reconstruction and the data were acquired by means a surgical navigation system (BLU-IGS, Orthokey, USA). Comparisons of pre- and post-reconstruction laxities were made using paired Student t-test (P=0.05) within the same group; comparison between ADB and SBLP groups was indeed performed using independent Student t-test (P=0.05), analysing both starting pre-operative condition and post-operative one.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 472 - 472
1 Sep 2012
Harvey-Kelly K Kanakaris N Ahmad M Obakponovwe O Giannoudis P
Full Access

Introduction

The aim of this study was to evaluate the health quality of life and return to sports activities following pelvic ring injuries.

Patients and Methods

Between January 2006–2007 patients treated in our institution with pelvic fractures were eligible to participate. Inclusion criteria were adult patients. Exclusion criteria were children and pathological fractures. Data recorded included demographics, injury mechanism, fracture pattern, Injury severity score (ISS), associated injuries, method of fixation, complications and functional outcome. Health related quality of life was assessed using the (EuroQol) and return to sports activities was evaluated using a return to sports questionnaire. The minimum follow up was 24 months (24–39)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 12 - 12
1 Sep 2012
Skettrup M Kjersgaard AG Colding C Solgaard S
Full Access

Introduction

The postoperative management of patients after total hip replacement traditionally includes restrictions of movements and the use of aids (toiletelevation, sleeping pillow, a.o.) in the first 3 months after operation. Few studies have investigated the benefit of such restrictions. The aim of the present study was to evaluate how patients with total hip replacements (THR) are doing with and without restrictions in the first 3 months after surgery, and if walking ability and patients satisfaction was influenced by the postoperative regime.

Patients and Methods

80 patients undergoing primary uncemented THR were randomized to either the conventional regime with restrictions of movement and obligatory use of aids, or a postoperative regime without restrictions. Surgery was performed through a posterolateral short incision. The femoral component was the uncemented Bimetric prosthesis, non collared with HA coating, and a 36 mm femoral head. The cup was the Trilogy cup with a highly crosslinked polyethylen liner. No postoperative drainage was used and immediate weight bearing was allowed in both groups. We monitored walking speed, TUG score (timed up and go) and VAS pain score. The patients were scored by a trained physiotherapist preoperatively, 2 times each day during admission, and 14 and 90 days after surgery. Radiographic examination was performed after 3 days and after 3 months. At the 3 months evaluation a SF-36 score was registered.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 568 - 568
1 Sep 2012
Hussain A Kamali A Li C Ashton R
Full Access

INTRODUCTION

Whilst there is a great deal of research on hip implants, few studies have looked at implant orientation and the subsequent effect upon the wear performance of a hip resurfacing. This study aimed to measure implantation angles through radiographic analysis and linear wear for retrieved acetabular cups in order to investigate possible causal links between wear and implant orientation.

MATERIALS & METHODS

Seventy Birmingham Hip Resurfacing (Smith & Nephew, UK) cups with known time in vivo were analysed. Linear wear of retrieved cups were assessed using a Talyrond 290 roundness machine. Deviations from the characteristic manufactured profile, was identified as a region of wear. Polar measurements across the wear region were taken to determine wear. The linear wear rate (LWR) of a component was defined as the linear wear (μm) divided by the duration of the implant life in vivo (years). Cups which showed the wear crossing over the edge of the cup were classified as edge loaded (EL). For all non-edge loaded (NEL) cups, the wear area was within the bearing surface. Cup orientation angles were conducted for 31 cups. This was determined by superimposing BHR models of appropriate size, generated by CAD ProEngineer Wildfire 4, onto anterior-posterior x-rays. Anatomical landmarks and specific features of the BHR were used as points of reference to determine cup version and inclination angles.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 178 - 178
1 Sep 2012
Wang Y Bunger C Hansen E Hoy K Wu C
Full Access

Objective

To identify risk factors for the presence of distal adding-on in Lenke 1A scoliosis and compare different treatment strategies.

Summary of Background Data

Distal adding-on is often accompanied by unsatisfactory clinical outcome and high risk of reoperation. However, very few studies have focused on distal adding-on and its attendant risk factors and optimal treatment strategies remain controversial.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 341 - 341
1 Sep 2012
Bernstein M Desy N Huk O Zukor D Petit A Antoniou J
Full Access

Introduction

Metal-on-metal (MoM) articulations in total hip replacement (THR) have become an attractive option for young, active patients. Short-term reports have demonstrated elevated systemic metal ion levels in the blood and urine. Disseminated concentrations of cobalt and chromium have raised concern regarding cellular toxicity, chromosomal damage and adverse local soft tissue reactions.

Long-term studies are required to support the increased use of MoM bearings in younger patients given their potential deleterious effects. The purpose of the current study was to report the 7–13 year clinical, radiographic, and metal ion results in patients following MoM THR.

Methods

We prospectively followed 165 patients (196 hips) after second-generation MoM THR between July 1997 and November 2003. Functional outcome was measured using the Harris Hip Score (HHS) and the University of California Los Angeles (UCLA) Activity Score. Radiographic analysis was performed using Einzel-Bild-Roentgen-Analyse (EBRA) by two of the authors blinded to the study. Cobalt and chromium metal ions were measured from whole blood and analyzed using inductively coupled plasma-mass spectrometry.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 343 - 343
1 Sep 2012
Volpin G Yacovi T Lichtenstein L Kirshner G Grimberg B Shtarker H Kaushanski A Stolero Z
Full Access

INTRODUCTION

In recent years the age of world's population has risen and with it there has been a significant increase in the frequency of hip fractures in the elderly. These fractures are known to increase morbidity and mortality. However, little is known about the frequency and characteristics of patients who sustain a second hip fracture. We examined the incidence and the underlying associated medical disorders of patients with a second fracture in the other hip.

MATERIAL & METHODS

This study consists of 132/1208 Pts. (10.9%) treated in our department between 1998–2006 that had a secondary hip fracture 1–9 years following the first hip fracture. We examined the most common complications following surgery of this type, the most common related illnesses among these patients, and the influence of post-surgical rehabilitative care on the patients' return to daily functioning.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 48 - 48
1 Sep 2012
Yates E Highton L Hakim Z Woodruff M
Full Access

Introduction

More than 60% of patients presenting with a hip fracture have significant medical co-morbidities and a one year mortality rate between 14% and 47%. The rating scale for the American Society of Anaesthetists (ASA) is a reliable predictor of both surgical risk and mortality with ASA 4 patients having 100% mortality at one year.1,2

Aims

Our aim was to establish a mortality rate for fractured neck of femur patients at three months and twelve months, and to ascertain the mortality of patients with an ASA 4 grading. Ultimately, should we be operating on this high risk cohort of patients'. We also chose to analyse our current practice in the management of displaced intracapsular neck of femur fractures in patients 90 years of age and over.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 246 - 246
1 Sep 2012
Van Der Weegen W Hoekstra H Sybesma T
Full Access

INTRODUCTION

Cementless Total Hip Replacement surgery is a well established procedure for relative young patients with severe hip disease. Excellent long term clinical results have been published on the performance of the femoral component. With growing clinical experience, our concern focused on excessive wear of the Ultra High Molecular Weight Polyethylene (UHMWPE) ringloc liner of the Mallory Head cementless Total Hip Prosthesis. After its introduction in our clinic in 1997, this implant is still in use without any modification. We were concerned that due to premature liner wear, the performance of this implant would not be compliant with the international guideline on implant survival (NICE guidelines: at 10 year follow up, 90% of all implants should still be in situ). Our objective was to establish the amount of liner wear in our first 200 MH implants.

METHODS

Our first 200 patients consecutively treated with Mallory Head prostheses were followed up to obtain a recent digital image. Follow up was complete for 181 (90.5%) of our 200 patients. Ten had died and nine were not able or willing to come for follow up. The mean duration of follow up was 8.3 years (range: 8–13). The 181 recent digital images were classified as either excessive wear or no excessive wear by two independent orthopedic surgeons. Next, liner wear was measured in the 2D frontal plane using PolyWare Pro/3D Digital Version Rev 5.1 software (Draftware Developers, Conway, USA). A threshold for excessive liner wear was set at 0.2mm/year, according to literature.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 247 - 247
1 Sep 2012
Grammatopoulos G Pandit H Taylor A Whitwell D Glyn-Jones S Gundle R Mclardy-Smith P Gill H Murray D
Full Access

Introduction

Since the introduction of 3rd generation Metal-on-Metal-Hip-Resurfacing-Arthroplasty (MoMHRA), thousands of such prostheses have been implanted worldwide in younger patients with end-stage hip osteoarthritis. However, no independent centre has reported their medium-to-long term outcome. The aim of this study is to report the ten year survival and outcome of the Birmingham Hip Resurfacing (BHR), the most commonly used MoMHRA worldwide.

Methods

Since 1999, 648 BHRs were implanted in 555 patients, the majority of which were male (326). The mean age at surgery was 52.1years (range: 17–82), with primary OA as most common indication (85%). Mean follow up was 7.1years (range: 1–11). The Oxford Hip Score (OHS) and UCLA questionnaires were sent to all patients. Implant survival was established, with revision as the end point. Sub-analysis was performed by gender, femoral component size (small: <45mm, standard: 46–52, large: >53mm) and age at surgery (young:<50yrs, old:>50yrs).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 151 - 151
1 Sep 2012
Nijs S Hardeman F
Full Access

Introduction

Analysing the results of angular stable osteosynthesis in large groups of patients can give us an indication of the possibilities and limitations of both angular stable nailing and plating.

Material and Methods

Fractures have been classified using the AO-classification system.

To judge vascularisation of the head fragment we use the criteria as described by Hertel.

We considered fracture reduction as adequate when the CCD-angle could be restored, with a maximum of 10° varus or valgus malalignment and a maximal persistent tuberosity displacement equal to or less than 3 mm in any direction.

An independent investigator collects information on reoperations based on: patient interview, hospital data and contact with the operating surgeon if the revision took place elsewhere. Reoperation is defined as any secondary surgical procedure after the initial open reduction and fixation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 52 - 52
1 Sep 2012
Van Der Linden H Van Der Zwaag H Konijn L Van Der Steenhoven T Van Der Heide H Nelissen R
Full Access

Introduction

Malrotation following total knee replacement is directly related to poor outcome. The knowledge of proximal and distal rotational axes and angles of the femur is therefore of high importance. The aim of the study was to determine whether the most used proximal and distal femoral angles; femoral anteversion angle (FAA) and posterior condylar angle (PCA) were different within individuals, between right, left and gender. As well, we studied whether the “inferior condylar angle” is correlated to the PCA and therefore useful in determining the rotation of the distal femur.

Material and Methods

From 36 cadavers the femora were obtained and after removing the soft tissue a Computed Tomography (CT) scan was made. Three angles were measured: (i) the FAA between femoral columnar line (FHNL) and posterior condylar line (PCL), (ii) the PCA between anatomical transepicondylar line (TEL) and PCL, (iii) the inferior condylar angle (ICA) between the TEL and inferior condylar line (ICL). Statistical analysis of comparative relationships between the different angles was examined by calculating correlation coefficients and a paired t-test.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 251 - 251
1 Sep 2012
Sturdee S Duffy D Dimitriou R Giannoudis P Templeton P
Full Access

Purpose

The purpose of this study was to prospectively evaluate the rehabilitation outcome of children following operative and non-operative stabilisation of long bone fractures sustained in conjunction with an acquired brain injury (ABI).

Materials and Methods

Between 1996 and 2002, children up to 16 years of age who were admitted to the Paediatric Intensive Care Unit (PICU) with an ABI and concomitant tibial or femoral shaft fractures were considered eligible for inclusion. Children who died or were unable to walk before the accident were excluded. All data relating to the sustained injuries, the duration of PICU inpatient stay, the fracture treatment and the functional outcome were collected prospectively. The severity of the injuries was assessed using the Injury Severity Score (ISS) and the Glasgow Coma Score (GCS). The duration of time was taken from admission to reaching rehabilitation milestones; the ability to sit, stand and walk was then assessed. Total duration of hospital inpatient stay and mobility on discharge were also recorded. Operative skeletal stabilisation included external or internal fixation, as well as flexible intramedullary nailing. Statistical analysis was performed using the Mann-Whitney U Test.


Background

We compared pain relief after total hip arthroplasty using periarticular intraoperative injection along with single dose post operative injection of local anesthetic (THA) with the well-established practice of epidural infusion.

Methods

70 patients undergoing elective THA under combined spinal anaesthesia were randomly assigned to receive either (1) continuous epidural infusion (group B) or (2) infiltration around the hip joint with a mixture of 100 ml of bupivacaine (2 mg/ml) + 1ml ketorolac (30mg/ml) and 0.5ml epinephrine (1mg/ml) at the conclusion of surgery combined with one postoperative intraarticular injection of 20 ml. of Bupivacaine 0.5% + 1ml ketorolac (30mg/ml)+ 0.5 ml. epinephrine (1mg/ml) through an intraarticular catheter (group A).

All patients received acetoaminophen 1gm 8 hourly for 72 hrs and injection ketoralac 30mg every 6 hourly IV(15mg if >65 yr 30mg if <65 yr). Breakthrough pain in any group (VAS >7) was treated by injection fentanyl 20 μg bolus at 10 min. interval till VAS reduced to < 4. If VAS 4–7 injection tramadol 50mg IV was given if VAS continued to be >4 after 15 min. then injection fentanyl 20 μg bolus was given at 10 min interval till VAS <4.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 157 - 157
1 Sep 2012
Rahbek O Deutch S Kold S Soejbjerg JO Moeller-Madesen B
Full Access

Introduction

Chronic radial head dislocation in children after trauma is a serious condition. Often the dislocation is overseen initially and is a part of the Monteggia fracture complex with anterior bowing of the ulna. Typical complaints are pain, decreased ROM and cubitus valgus. Radial head dysplasia often occurs. The treatment of this condition is debated. Only few series of patients treated with open reduction and ulnar osteotomy exists with long-term follow up. We present a group of rare patients with long-time follow-up treated by only two surgeons through a period of 16 years.

Materials and Methods

All 16 patients had anterior radial head dislocation (Bado type 1). Mean age at the time of traumatic dislocation was 6 years ranging from 2 to 9. We found a mean delay of 17 (range 1–83) months before open reduction and ulnar open wedge osteotomy. In 8 cases reconstruction of the annular ligament was performed and in 6 patients temporary transarticular fixation of the radial head with a k-wire was performed. Follow-up time was 8 (range 3–17) years postoperatively. Patients were investigated with bilateral x-ray, arthrosis status, congruency of the radiocapitellar joint, Oxford Elbow Score, force measurements and range of motion.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 546 - 546
1 Sep 2012
Caruso G Lorusso V Setti S Cadossi R Massari L
Full Access

A multicenter retrospective analysis of patients treated for tibial fracture was conducted to develop a score that correlates with fracture healing time and, ultimately, to identify the risk gradient of delayed healing.

The clinical records of 93 patients treated for tibial fracture at three orthopaedic centers were evaluated. Patients were considered healed when full weight bearing was allowed and no further controls were scheduled. For the purpose of our analysis, we separated patients healed within or after 180 days.

Patient's risk factors known to be associated to delay healing, as well as fracture morphology and orthopaedic treatment were recorded in an electronic Case Report Form (e-CRF). Information available in the literature was used to weight the relative risk (RR) associated to each risk factor; values were combined to calculate a score to be correlated to the fracture healing time: L-ARRCO (Literature-Algoritmo Rischio Ritardo Consolidazione Ossea). Among all information collected in e-CRFs, we identified other risk factors, associated to delayed healing, that were used to calculate a new score: ARRCO. Univariate logistic analysis was used to determine a correlation between the score and healing time. Analysis by receiver operating characteristic (ROC) and calculation of the area under the curve (AUC) were used for sensitivity and specificity.

Complete information was available for 53 patients. The mean value of the L-ARRCO score among patients healed within 180 days was 5.78 ± 1.59 and 7.05 ± 2.46 among those healed afterwards, p=0.044. The mean value of the ARRCO score of patients healed within 180 days was 5.92 ± 1.78 and 9.03 ± 2.79 among those healed afterwards, p<0.0001. The ROC curve shows an AUC of 0.62±0.09 for L-ARRCO and an AUC of 0.82±0.07 for ARRCO, (p<0.0001).

We have shown that the ARRCO score value is significantly correlated to fracture healing time. The score may be used to identify fractures at risk of delayed healing, thus allowing surgeon's early intervention to stimulate osteogenesis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 255 - 255
1 Sep 2012
Moroni A Hoque M Micera G Sinapi F Calbucci L Maccagnan E Giannini S
Full Access

Introduction

Metal-on-metal hip resurfacing (MOMHR) is a good surgical indication for young active patients. However, it cannot be used in patients with an excessively short femoral head/neck. To address these cases, a new surgical technique has been developed comprising femoral head augmentation using impacted morcellized bone grafts.

Methods

32 osteoarthritis patients who had severe congenital insufficiency of the femoral head/neck were treated with MOMHR combined with femoral head augmentation. Mean patient age was 49 ± 9 years (18–66). The required amount of augmentation was calculated on preoperative X-rays and confirmed during surgery. Using specially designed instrumentation, bone chips produced while reaming the socket and trimming the head were impacted onto the head to achieve the desired reconstruction and lengthening. Finally, the femoral component was cemented.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 548 - 548
1 Sep 2012
Purghel F Badea R Jemna C Ciuvic R Ivan A
Full Access

AIMS

Pure tibial plafond traumatic pathology (excluding trimalleolar fractures) is rare but troublesome, considering the surgical challenges and the long term disability perspective. Treatment involves a wide variety of implants and techniques, and the procedures choice and timing is highly dictated by the soft tissue damage. We designed this study to assess the status of our patients operated with internal, external or combined procedures.

METHODS

In a retrospective study, between July 2008 and July 2010 we reviewed 24 patients with available follow-up data. We reviewed the pre- and post-operative imaging available and the immediate follow-up data. A form is currently mailed to the patients to self-evaluate the general physical, mental and employment status, and also the affected limb, using general approved questionnaires. Data from this form is still in process.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 550 - 550
1 Sep 2012
Singisetti K Raju P Langton D Nargol A
Full Access

INTRODUCTION

A detailed clinical examination and investigations are required to evaluate the cause of persisting groin pain following a metal on metal (MoM) hip replacement. Adverse reaction to metallic debris (ARMD) is an emerging problem with MoM hip replacements. It is an umbrella term encompassing metallosis, pseudo-tumors and aseptic lymphocytic vasculitis associated lesions (ALVAL). The role of imaging in the diagnosis of this complex problem is still unclear. A study was undertaken to evaluate the efficacy of ultrasound in diagnosis of ARMD following a MoM hip replacement.

METHODS

The study group included 35 patients with a clinical and histological diagnosis of ARMD, who had a preoperative ultrasound. All ultrasound procedures were performed on the anterior and lateral aspects of the painful hip with a high frequency probe of 9–13 MHz (Sonoline Antares – Siemens).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 457 - 457
1 Sep 2012
Ishibe M Kariya S
Full Access

BACKGROUND & AIM

Most previous studies found that the rate of dislocation following primary THA was 2 to 3 % on average. It is expected that minimally invasive (MI) THA has fewer dislocations after surgery because it causes less muscle damage. To ascertain the risk factors of dislocation, we conducted a retrospective study of the occurrence of dislocation after MI-THA in Japanese patients.

METHODS

From June 2003 when we began MI-THA to August 2010 primary MI-THAs were performed on 2,042 hips; 1,997 hips with mini-posterior approach (a mean incision of 7 cm) with the repair of posterior soft tissues and 45 hips with other approaches. The dislocation after MI-THA was studied with respect to age, sex, body mass index, the use of navigation system, femoral head size, cup size and approaches. The period of follow-up was from six weeks to seven years.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 63 - 63
1 Sep 2012
Kaneko M Ohnishi I Bessho M Matsumoto T Ohashi S Tobita K Nakamura K
Full Access

Introduction

Spinal aBMD only explains 50–80% of vertebral strength, and the application of aBMD measurements in isolation cannot accurately identify individuals who are likely to eventually experience bone fracture, due to the low sensitivity of the test. For appropriate treatment intervention, a more sensitive test of bone strength is needed. Such a test should include not only bone mineral density, but also bone quality. Quantitative computed tomography-based finite element methods (QCT/FEM) may allow structural analyses taking these factors into consideration to accurately predict bone strength (PBS). To date, however, basic data have not been reported regarding the prediction of bone strength by QCT/FEM with reference to age in a normal population. The purpose of this study was thus to create a database on PBS in a normal population as a preliminary trial. With these data, parameters that affect PBS were also analyzed.

Methods

Participants in this study comprised individuals who participated in a health checkup program with CT at our hospital in 2009. Participants included 217 men and 120 women (age range, 40–89 years). Exclusion criteria were provided. Scan data of the second lumber vertebra (L2) were isolated and taken from overall CT data for each participant obtained with simultaneous scans of a calibration phantom containing hydroxyapatite rods. A FE model was constructed from the isolated data using Mechanical Finder software. For each of the FE models, A uniaxial compressive load with a uniform distribution and uniform load increment was applied. For each participant, height and weight were measured, BMI was calculated. Simple linear regression analysis was used to estimate correlations between age and PBS as analyzed by QCT/FEM. Changes in PBS with age were also evaluated by grouping participants into 5-year age brackets. One-way analysis of variance was used to compare average PBS for participants in each age range. Mean PBS in the 40–44 year age range was taken as the young adult mean (YAM). The ratio of mean PBS in each age group to YAM was calculated as a percentage. A multivariate statistical technique was used to determine how PBS was affected by age, height, weight, and BMI.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 164 - 164
1 Sep 2012
Riis T Ogarrio H Jorgensen H Lauritzen J Van Der Mark S Duus B
Full Access

At Bispebjerg University Hospital in Denmark, an Optimized Hip Fracture Program, (OHP) is the standard of care for all hip fracture patients. Part of OHP is pain treatment with a femoral nerve catheter placed at the emergency room, dosed 4 times a day with Bupivacain until 4 days after surgery, combined with systemic analgesics as needed. In 2008, a database and a bio bank were created at the ward including all hip fracture patients to make a better description of the population and as a tool for further optimisation of the OHP. One of the aims was to identify possible subgroups having specific complications, which could lead to a differentiation of the OHP by markers known at the time of admission. In this analysis, we will focus on postoperative pain that inhibits mobilization by fracture type and type of surgery.

Methods

A consecutive cohort of 898 hip fracture patients hospitalized within two years from September 2008 to July 2010 was used for this study. Patients coming from nursing homes were excluded from the study, since nearly all are discharged 1 or 2 days after surgery to rehabilitation. If the exact type of fracture was not known, or if the patient was admitted for rehabilitation after surgery at another hospital, the patient was also excluded. 508 patients were thus included in the study. Mean age 80.0 years (SD:23.7), 72.1% women and 27.9% men.

Mobilization inhibited by postoperative pain as documented in the patient files was registered in the database. Overall mobilization was inhibited by pain in 26.7% of the 508 patients included.

The following fracture types were studied: Femoral neck Garden 1–2, Femoral neck Garden 3–4, Pertrochanteric Evans 1–2, Pertrochanteric Evans 3–5, Basocervical and Subtrochanteric.

Results

Mobilization inhibited by pain was not significantly associated with type of surgery:

Cannulated Hip Screws 16/80 (20.0%), sliding hip screw 23/94 (24.5%), Intramedullary Nail 63/186 (33.9%), partial hip replacement 33/144 (22.9%), total hip replacement 1/5 (20.0%). P = 0.09 chi square.

On the other hand mobilization inhibited by pain was significantly associated with fracture type:

Femoral neck Garden 1–2: 13/64 (20.3%), Femoral neck Garden 3–4: 38/172 (22.1%), Pertrochanteric Evans 1–2: 18/69 (26.1%), Pertrochanteric Evans 3–5: 46/149 (30.9%), Basocervical: 6/28 (21.4%), Subtrochanteric 15/27(55.6%). P = 0.009 chi square.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 555 - 555
1 Sep 2012
Starks I Frost A Wall P Lim J
Full Access

The management of pelvic fractures remains a challenging problem for orthopaedic surgeons. The prompt recognition of unstable fracture patterns is important in reducing mortality and morbidity. It is perceived wisdom that a fracture of the transverse process of L5 is a predictor of pelvic fracture instability. There is a paucity of evidence in the literature to support this belief. The aim of our study was to determine if a fracture of the transverse process of L5 was a predictor of pelvic fracture instability.

The Hospital Trauma database was reviewed. Between 2006 and 2009, 65 pelvic fractures were identified. They were classified according to the Burgess and Young classification. There were 37 stable and 28 unstable fractures. 14 patients had an associated fracture of the transverse process of L5; 9 were associated with an unstable fracture pattern. The odds ratio was 3; the relative risk 1.7.

A fracture of the transverse process of L5 is associated with an increased risk of pelvic fracture instability. Its presence should alert the attending physicians to the possibility of an unstable injury.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 459 - 459
1 Sep 2012
Aydogdu S Yagci T Sezak M Sur H
Full Access

We aimed to investigate the effect of Seprafilm®, a synthetic biomembran, on the intra-articular adhesion formation in an experimental arthrofibrosis model.

Twenty male white rabbits were randomly allocated into two groups of 10 animals in each. A standard surgical procedure aiming at the development of arthrofibrosis and including medial parapatellar arthrotomy, lateral eversion of the patella, partial synovectomy and debridement of anterior of supracondylar area and patella joint surface by scalpel was performed on all rabbits' right knees. Group 1 rabbits served as controls, and in Group 2 rabbits a Seprafilm®, barrier placed into the described area. In both groups, after surgery, knee joint was immobilized by a no.5 wire suture passing from the ankle and groin and keeping the joint in 140° of flexion. At 6th week, all animals were sacrificed and adhesion formation was evaluated both macroscopically and histo-pathologically. All data were semi-quantified and analyzed statistically by Fisher's exact test.

While all rabbits in control group displayed different rates of adhesion macroscopically (62.5% severe, 25% moderate, 12.5% mild), none in the study group had it. The average macroscopic adhesion score was 2.5 ± 0.75 in control group, and 0 in Seprafilm® group. Histopathologic evaluation also revealed microscopic adhesion in all rabbits in control group, but none in Seprafilm® group. Fibroblast proliferation in Seprafilm® group (100% mild) was significantly lower than in control group (62.5% severe, 37.5% moderate) (p<0.05).

In conclusion, use of Seprafilm® as a mechanical barrier may be of value against the formation of arthrofibrosis in risky knees such as septic and traumatic ones.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 266 - 266
1 Sep 2012
Cinotti G Giannicola G Ferrari E Corsi A Riminucci M Bianco P
Full Access

Posterolateral spinal fusion (PSLSF) in rabbits is a challenging model for bone substitutes because the transverse processes are extremely thin and the space to be filled with bone is greater than critical and meiopragic in terms of vascularity.

Several investigators have shown beneficial effects of PRP in bone and soft-tissue healing processes. However, controversial results have been reported in clinical setting analysing the effectiveness of PRP. Aim of the present study was to test the effectiveness of PRP in experimental model of PLSF in rabbits.

MATERIAL AND METHODS

20 White females New Zeland Rabbits were used. Seven rabbits (Group 1) had PRP plus carrier on the right side (Group 1A) and plus carrier and fresh bone marrow on the left side (Group 1B). Seven rabbits (Group 2) had carrier alone on the right side (Group 2A) and carrier plus fresh bone marrow on the left side (Group 2B). Six rabbits (Group 3) had sham operation on both right and left sides. Animals were sacrificed 6 months after surgery and the lumbar spine submitted to radiolographic and histologic analysis. Vascular density (VD) was also assessed in the different zone of the grafted material.

RESULTS

Radiographs showed a complete fusion in 83% of group 1A and in 83% of group 1B, and in 86% of group 2A and 2B. Pseudarthrosis or non union, was observed in 1 specimen of group 1B and 2A and in all specimens of group 3 (sham). In contrast to radiographic results, no specimen showed a complete bony bridge between the transverse processes on histologic analysis. VD was significantly greater in the periapophyseal compared to the interapophyseal region of the graft material. However, no significant difference was found in the VD between groups.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 463 - 463
1 Sep 2012
Gaskin J Forde-Gaskin D Ajekigbe L
Full Access

Introduction

Flexor tendon injuries are quite common injuries. They can result in persisting functional deficit if not repaired and appropriately rehabilitated. We look at flexor tendon injuries over a period of 1 year and re-audited three years later.

Method

We audited all flexor tendon injuries that were treated at our institution and repeated the same audit three years after. We looked at various aspects of the injuries including the site injured, the zone of injury, other structures injured, the type of repair and material used as well as the rehabilitation regime.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 365 - 365
1 Sep 2012
Giannini S Faldini C Pagkrati S Nanni M Leonetti D Acri F Miscione MT Chehrassan M Persiani V Capra P Galante C Bonomo M
Full Access

Objective

Combined metatarso-phalangeal and inter-phalangeal deformity represents about 1% of hallux valgus deformity, and its treatment remains a debated topic, because a single osteotomy does not entirely correct the deformity and double osteotomies are needed. The aim of this study is to review the results of 50 consecutive combined metatarso-phalangeal and inter-phalangeal hallux valgus treated by Akin proximal phalangeal osteotomy and SERI minimally invasive distal metatarsal osteotomy.

Material and Methods

Fifty feet in 27 patients, aged between 18 and 75 years (mean 42 years) affected by symptomatic hallux valgus without arthritis were included. Two 1-cm medial incisions were performed at the metatarsal neck and at proximal phalanx. Then SERI osteotomy was performed to correct metatarso-phalangeal deformity and Akin osteotomy was performed to correct interphalangeal deformity. Both osteotomies were fixed with a single K-wire. A gauze bandage of the forefoot was applied and immediate weight-bearing on hindfoot was allowed. K-wire was removed after 4 weeks. All patients were checked at a mean 4 year follow-up.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 168 - 168
1 Sep 2012
Von Rueden C Trapp O Hierholzer C Prohaska S Bräun K Wurm S Buehren V
Full Access

Background

For the treatment of proximal humeral fractures two major therapeutic principles can be employed: Intramedullary nailing (PHN) or locking plate osteosynthesis. Aim of this study was to evaluate and compare clinical and radiological long-term outcome of proximal humeral fracture stabilization using PHN or angular stable plating. In addition, we discussed advantages and disadvantages of both techniques and aimed at establishing criteria which operative technique should preferentially be utilized for selected fracture configurations.

Materials and Methods

In a prospective study between 2003 and 2010 we analyzed 72 patients with proximal humeral fracture who had been treated by PHN (44 patients) or angular stable plating (28 patients) in a European Level 1 Trauma Center. In the two cohort groups the following epidemiologic data was found. 46 patients were women, and 26 men with a mean age of 60.6 years (range 18–91). Follow-up was performed 38–82 months after accident, on average. Mechanism of injury was fall in 59, motor cycle accident in 4, bike accident in 8 patients, and fall from horse in 1 patient. Duration time between accident and operation was 2.8 days on average. Osteoporosis was previously known in 20 out of all evaluated patients (plate: 7/28; nail: 13/44). Fractures were classified using the Neer classification and Binary description system: There were 35 3-part fractures (PHN: 26; plate: 9) and 37 4-part fractures (PHN: 18; plate: 19), respectively. Functional and radiological outcome was assessed in a range of 38–82 months after trauma using Constant Score.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 41 - 41
1 Sep 2012
Sultan M Sultan M Fazakerley S Hodhody G Kurdy N Mccollum C
Full Access

Introduction

Long-term ankle pain, stiffness or swelling are frequent following ankle fracture. We investigated whether engineered compression stocking (ECS) influenced functional outcome and quality of life (QoL).

Methods

Ninety patients < 72 hours following ankle fracture, (59 conservative and 31 operative fixation) were randomised to i) ECS + air-cast boot or ii) air-cast boot alone. Patients were followed at 2, 4, 8, 12 weeks and 6 months for Olerud Molander Ankle Score (OMAS), American Orthopaedic Foot and Ankle Score (AOFAS) and SF12v2 score with duplex imaging for deep vein thrombosis (DVT) at 4 weeks. 22 controls managed by plaster of paris (POP) were also assessed at 6 months only.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 252 - 252
1 Sep 2012
Madsen C Joergensen H Lind B Ogarrio H Duus B Lauritzen J
Full Access

Introduction

The calcium-PTH-vitamin D-axis has long been highlighted for its effects on bone status and much interest has been given to how this relates to the risk of sustaining an osteoporotic fracture. Little attention has on the other hand been given to how disturbances in this axis, as for example secondary hyperparathyroidism (SHPT), relate to mortality among hip fracture patients. We therefore wanted to determine if SHPT could predict mortality in this group of patients.

Methods

The study included 562 hip fracture patients (HF) (age 70 years) admitted to a Danish university hospital. Each hip fracture patient was exactly matched according to age and sex with two controls randomly chosen from a control population of approximately 248000 subjects. The control group (Con) (n=1124) consists of subjects who have had PTH, total calcium (Ca) and 25OH-vitamin D (VitD) measured at the General Practitioners Laboratory of Copenhagen after referral from their general practitioner. Of the HF's 462 had a Ca measurement, 440 had a PTH measurement and 439 had a VitD measurement.

Basic characteristics (values for age, Ca, PTH and VitD are mean (SD)): Sex (females/males) (%): 73.8/26.2. Age (years): 82.9 (5.7). Ca (mmol/l): Con 2.34 (0.13), HF 2.27 (0.13), p<0.0001 (chi-square). PTH (pmol/l): Con 6.4 (5.8), HF 6.6 (5.4), p=0.4 (chi-square). VitD (nmol/l): Con 53.3 (30.1), HF 49.3 (29.6), p=0.02 (chi-square).