View my account settingsUntil recently, surgical treatments for advanced ankle osteoarthritis have been limited to arthrodesis or ankle replacement. Supramalleolar osteotomy provides a joint-preserving option for patients with eccentric osteoarthritis of the ankle, particularly those with varus or valgus malalignment.
The aim of the study was to evaluate radiological and functional outcomes of patients undergoing shortening supramalleolar osteotomy for eccentric (varus or valgus) osteoarthritis of the ankle. We performed a prospective review of patients from 2008 onwards. Osteotomy was the primary surgical procedure in all patients after failure of non-operative measures.
Pre-operative standing antero-posterior and Saltzman view radiographs were taken to evaluate degree of malalignment requiring correction. Radiological and clinical outcomes were assessed at 3, 6 and 12 months post-operatively. Radiographs were reviewed for time to union.
Patients were assessed on an outpatient basis for ankle range of motion as well as outcomes using AOFAS scores.
33 patients were reviewed over a 7 year period. Mean follow-up was 25 months (range 22–30). Mean time to radiological union was 8.6 weeks (range 8–10); there were no cases of non-union. There was a statistically significant improvement in functional scoring (P<0.001); mean AOFAS score improved from 34.8 (range 15–40) pre-operatively to 79.9 (range 74–90) at 12 months post-operatively. There was no significant change in pre- and post-operative range of motion. 2 patients required revision surgery at 12 months; one to arthrodesis and one to ankle replacement.
Supramalleolar osteotomy is a viable joint preserving option for patients with eccentric osteoarthritis of the ankle. It preserves motion, redistributes forces away from the affected compartment and corrects malalignment, providing significant symptomatic and functional improvement.
The proportion of younger patients undergoing total knee arthroplasty (TKA) is increasing and predictions state that the 45–54 age group will be the fastest growing group by 2030. We aim to collate data across studies to assess functional outcomes following total knee replacement in patients under 55 years of age. Secondary outcomes include implant survival and complications will also be reviewed.
The search identified 980 studies for title and abstract review. 43 full-texts were then assessed. 13 studies underwent quality assessment and data extraction from them. PRISMA guidelines were followed throughout. Outcomes extracted included pre- and post-operative functional scores, range of motion (ROM) and patient satisfaction. Clinical complications and survival were also recorded.
Across 13 studies we were able to demonstrate 54-point improvement in clinical Knee Society Score and a 2.9° improvement in range of motion. Satisfaction rate was 85.5%. Revision rate was 5.4% across 1323 TKAs. Risk of revision for aseptic loosening was 0.37% per year.
Total knee arthroplasty is an excellent treatment option for the young osteoarthritic knee with a >50% improvement in functional knee scores. Satisfaction is high and the revision rate remains under 1% per year.
Despite the high success rates of Reverse Shoulder replacements, complications of instability & scapular notching are a concern. Factors reducing relative motion of implant to underlying bone which include lateral offset to centre of rotation, screw & central peg insertion angle and early osteo-integration are maximized in the Trabecular Metal Reverse total shoulder system. We present clinico-radiological outcomes over 72 months.
Analysis of a single surgeon series of 140 Reverse total shoulder replacements in 135 patients was done. Mean age was 72(range 58– 87 yrs); 81 females: 54 males. Indications were Rotator cuff arthropathy {n= 88} (63%); Osteo-arthritis with dysfunctional cuff {n= 22}(15%); post-trauma{n=23} (15%); revision from hemiarthroplasty {n=3} (2.4%) and from surface replacement {n=4} (2.8%)
All patients were assessed using pre-operative Constants and Oxford scores and clinical & radiographic reviews with standard X-Rays at 6 weeks, 3, 6,12 months and yearly thereafter. X rays included an AP view in 45 degrees of external rotation and modified axillary view. Inferior Scapular notching using the Nerot-Sirveaux grades and Peg Glenoid Rim Distance were looked into by a consultant musculoskeletal radiologist/ Orthopaedic surgeon/ Senior Fellow (post CCT) or a specialist Trainee (ST4 and above). Pain on the visual analogue scale decreased by 98% (9.1 to 0.8) (p<0.01). Constant score improved by 81.8% (12.4 to 68.1) (p<0.05), Oxford shoulder score by 76.7% (56 to 13) (p<0.05). 95.6% of Humeral stems had no radiolucent lines and 4.4% had < 2mm of lucency. Scapular notching was calculated using Sirveaux grades with Peg scapular base angle distance (PSBA) measurements on PACS with Siemens calibration (grade 1= 4 (2.8%); grade 2 =1; grade 3 =0; grade 4=0). 3.57% showed radiographic signs of scapular notching at 72 months. Range of Peg Glenoid Rim Distance was 1.66 to 2.31 cm. Power analysis showed 65 patients were needed to have an 80% power to detect relation of Peg Glenoid Rim Distance to Scapular notching. A likelihood ratio test from Logistic regression model to check correlation of Peg Glenoid Rim Distance to Scapular notching gave a p value of 0.0005. A likelihood ratio from Logistic regression gave a p value of 0.0004 for Infraglenoid Scapular spurs. Highest incidence of spurring was seen in Reverse Total Shoulder Replacements done for Trauma and lowest in patients who got the procedure for Osteoarthritis. Complications included two glenosphere revisions; two stitch abscesses and two Acromial fractures in patients who had a fall two years after the procedure. Improved surgical outcomes can be attributed to surgical technique and implant characteristics. Trabacular metal promotes early osteointegration which resists shearing action of Deltoid on Glenoid component. This allows early mobilisation. Deltoid split approach preserves integrity of Subscapularis and Acromial osteotomy and lateral clavicle excision improve exposure and prevent Acromion fracture. Positioning the Glenoid component inferiorly on the Glenoid decreases incidence of Scapular notching.
Our mid-term validated outcomes are promising with only 3.57% Grade I/II radiographic signs of scapular notching. Long term studies (10 year follow ups) are necessary to confirm its efficacy.
Coracoid fractures during screw insertion and graft osteolysis are serious concerns with standard screw fixation techniques in Latarjet procedure. This study tends to evaluate the outcome of mini open Latarjet using Arthrex mini-plate for coracoids graft fixation.
We did retrospective analysis of 30 patients with recurrent anterior shoulder instability after arthroscopic Bankart's repair. A low profile wedge plate (Arthrex) with two low profile screws was used for fixation of the coracoid graft. CT analysis was performed at final follow up to see graft union and results were evaluated using American shoulder and elbow score (ASES) and Western Ontario shoulder instability score (WOSIS).
Mean follow up time was 24 months. Postoperatively, mean forward elevation was 162.8 degrees and external rotation was 44.6 degrees. All patients returned to their previous occupation. None reported to be having any recurrent subluxation post-surgery. The mean ASES score was 92.5 while the mean WOSIS score was 76.84%. Only one patient had screw backing out from the plate. There was no case of coracoid graft osteolysis.
The mini-open Latarjet procedure with graft fixation with Arthrex mini-plate provides satisfactory outcome and stabilization in patients who present with dramatic bone loss and failed soft tissue reconstruction. It not only ensures early rehabilitation but also minimum loss of external rotation. The only drawback is the relatively high cost of the implant.
Optimal management of acute patellar dislocation is still a topic of debate. Although, conventionally it has been managed by non-operative measures, recent literature recommends operative treatment to prevent re-dislocations. Our study recommends that results of non-operative measures comparable to that of operative management.
Our study is the retrospective with 46 consecutive patients (47 knees) of first time patellar dislocation managed between 2012 and 2014. The study methodology highlighted upon the etiology, mechanism of injury and other characteristics of first time dislocations and also analysed outcomes of conservative management including re-dislocation rates. The duration of follow up ranged from 1 to 4 years.
Average age at first-time dislocation was 23 years (Range 10–62 years). Male:Female ratio was 30:17. Twisting injury was the commonest cause. 1 patient required open reduction but all others relocated spontaneously or had successful closed reduction. Medial Patello-Femoral Ligament injury was frequent associated feature. 11 knees
Conservative management of primary patellar dislocation is successful in majority of patients. Surgery should be reserved for the carefully selected patients with specific indications.
Management of bone defects is a common surgical challenge encountered following any high energy trauma. Femur fractures with bone loss account for 22% of all the fractures with bone loss/defect, and 5% to 10% of distal femur fractures are open injuries. It was estimated in 2008, that, more than 4.5 million open fractures occur annually in India.
In this retrospective study, patients who received bone allograft from our tissue bank between May 2012 and September 2015 were analysed. Of the 553 allografts issued, at that point in time, 26 were used in patients who underwent reconstruction for distal Femur fractures primarily. Fractures with defect or bone loss from 12 cc (1cm) to 144 cc (12cm) were treated with either Internal or External fixation and bone allograft. Morcellised cancellous, or a cortical strut, were used to fill or reconstruct the defect or void. The radiological outcome in terms of fracture union was assessed and Knee society score was used to assess the functional outcome. Complications such as non- union, infection, stiffness and need of revision or additional procedures were also assessed.
Osseous consolidation was achieved in all the 26 patients with a Median time of 24 weeks (16 to 60). The Median Functional Knee Society Score was 80, indicating satisfactory functional outcome. Infection was noted in one patient, but it was not attributed to the allograft. Additional minor procedures like bone marrow infiltration, corticotomy for bone lengthening were required in 10 patients. Our studycomprises the largest group of patients treated primarily with Allograft to reconstruct or fill the void of bone loss encountered with distal Femur fracture.
Reconstruction of massive bone defects, in patients of distal Femur fractures, with bone allograft, shows encouraging results. The surgeon can achieve the goal of restoring form and function of these difficult injuries in a single stage and the technique will provide the freedom to reconstruct the bony defect up to 150 cc (12 cm length) and recreate the anatomy to near normal. This allows for early mobilisation of patients and restoration of their daily routine at the earliest.
Distal femoral replacement is an operation long considered as salvage operation for neoplastic conditions. Outcomes of this procedure for difficult knee revisions with bone loss of distal femur have been sparsely reported.
We present the early results of complex revision knee arthroplasty using distal femoral replacement implant, performed for severe osteolysis and bone loss.
Retrospective review of clinic and radiological results of 25 consecutive patients operated at single centre between January 2010 and December 2014. All patients had single type of implant. All data was collected till the latest follow up. Re-revision for any reason was considered as primary end point.
Mean age at surgery was 72.2 years (range 51 – 85 years). Average number of previous knee replacements was 2.28 (range 1 to 6). Most common indications were infection, aseptic loosening and peri-prosthetic fracture. Average follow up was 24.5 months (range: 3–63 months). 1 patient died 8 months post-op due to unrelated reasons. Re-revision rate was 2/25 (8%) during this period. One was re-revised for aseptic loosening and one was revised for peri-prosthetic fracture of femur. Two other peri-prosthetic fractures were managed by open reduction and internal fixation. All 3 peri-prosthetic fractures occurred with low energy trauma.
It is noteworthy that there was no hinge or mechanical failures of the implant. Peri-prosthetic fracture in 12% of patients in this series is of concern. There are no similar studies to compare this data with. The length of the stem, type of fixation of the stem, weight of the distal femoral component of implant can be postulated as factors contributing to risk of peri-prosthetic fracture.
The dual mobility (DM) bearing concept was introduced to reduce the risk of dislocation in total hip arthroplasty (THA). Our aim was to evaluate the early outcomes following the utilisation of DM in primary and revision THA in our unit.
Prospectively collected data on all patients undergoing a DM bearing at was reviewed between July 2012and December 2015. The primary outcome assessed was dislocation, with a secondary outcome revision for any reasons. All data was gathered from patient clinical records and the digital picture archiving and communication system (PACS)
30 primary THA were undertaken and 54 revision THAin the time period described. 11 of the procedures involved a proximal femoral endoprosthesis. The mean age in the primary setting was 65 and 73 in the revision population. The main indications for using DM bearing in the primary setting were; trauma (40%), residual dysplasia (40%) and malignancy (17%). There were no dislocations in the primary THA category. Indications in the revision THA cohort included 33% for aseptic loosening, 11% for instability, 18% for ALVAL reactions, 20% for infection, 18% for fracture. 1 out of the 54 revision THA had one large bearing dislocation requiring closed reduction. Subsequent analysis confirmed that implant alignment was satisfactory and this was a patient compliance issue due to mental health concerns. To date no patient in either cohort required revision surgery. Overall dislocation rate was 1.2%.
Our early experience with DM bearings has been positive with no evidence of early failure or loosening. The dislocation rate overall has been low and matches the current large series in the literature.
Scaphoid fractures accounts for approximately 15% of all fractures of hand and wrist. Proximal pole fractures represent 10–20% of scaphoid fractures. Non –operative treatment shows high incidence of non-union and avascular necrosis. Surgical intervention with bone graft is associated with better outcome. The aim of this study was to evaluate the radiological and functional outcome of management of proximal pole scaphoid non-union with internal fixation and bone grafting.
We included 35 patients with proximal pole scaphoid non-union (2008–2015). All patients underwent antegrade headless compression screw fixation and bone grafting at King's College Hospital, London (except one, who was fixed with Kirschner wire). 33 patients had bone graft from distal radius and two from iliac crest. Postoperatively patients were treated in plaster for 6–8 weeks, followed by splinting for 4–6 weeks and hand physiotherapy. All the patients were analysed at the final follow-up using DASH score and x-rays.
Mean age of the patients was 28 years (20–61) in 32 men and 3 women. We lost three patients (9%) to follow up. At a mean follow up of 16 weeks (12–18) twenty three patients (66%) achieved radiological union. All patients but three (91%) achieved good functional outcome at mean follow up of 14 weeks (10–16).
A good functional outcome can be achieved with surgical fixation and bone graft in proximal pole scaphoid fractures non-union. Pre-operative fragmentation of proximal pole dictates type of fixation (screw or k wire or no fixation). There was no difference in outcome whether graft was harvested from distal radius or iliac crest.
The choice of stem length in total hip revision with impaction bone grafting of femur is essentially based upon the grade of cavitation of femur and surgeon's preference. The standard length stem has been often critiqued for the apprehension of peri-prosthetic fracture. Our study highlights the importance of proximal bone stock rather than distal cavitation in determining the length of femoral stem.
168 total hip revisions of 162 patients with impaction bone grafting and cemented standard C-stem (done with standardized technique) between 1995 and 2008 at a tertiary referral centre were included. Revisions for infection and segmental bone defects were excluded. Serial radiographs were retrospectively analysed by two people independently, using Endoklinik classification, Gruen zones and more and outcomes were analysed.
Mean follow-up of the 168 revision hips was 10.5 years (range 5 – 19.1 years). 14 patients (8.3%) were re-revised, reasons being, persistent deep infection (1.8%), repeated dislocations (1.2%), cup loosening (4.8%) and stem loosening (1.2%). Only 1 patient (0.6%) was re-revised due to stem loosening alone. No peri-prosthetic fractures or stem breakage were identified.
Use of standard stem length in hip revisions with impaction bone grafting doesn't increase the risk of peri-prosthetic fractures even during long term follow up period. This questions the principle of bypassing the distal cavitation of femur by 2 cortical diameters with the use of long stem. In our experience, a good proximal femur support aids in the performance of standard length cemented stems in revision for aseptic loosening irrespective of grade of distal cavitation for cavitory defects of femur treated with impaction bone grafting.
Tropical pyomyosistis is an uncommon condition in the United Kingdom. Early diagnosis and appropriate treatment are crucial for a good outcome. We had seen 13 cases in our previously published series from 1998 to 2009. This is an update showing a significantly increased incidence from 2010 to 2016.
A retrospective review of all cases of pelvic pyomyositis in our centre from January 2010 to April 2016 was undertaken from case notes and radiology reports. All children with clinical and radiographic evidence of pyomyositis were included. Since our previous publication we had changed our practice to get an MRI scan in all children who presented with a limp, fever and raised inflammatory markers, and had no effusion in the hip ultrasound scan.
We identified 24 children with a mean age of 7 years (range, 1 week to 14 years). MSSA (
Incidence of pyomyositis has increased dramatically in our population and early diagnosis can result in a good outcome. We recommend MRI scan in all patients who present with a clinical picture of septic arthritis of the hip but with no effusion.
The mid foot joints are usually the first to be affected in Charcot neuroarthropathy(CN). Reconstruction is technically demanding and fraught with complications. Fixation methods have evolved over time from cancellous screws, plates, bolts and a combination of these.
We present our experience of mid foot fusion in CN from a tertiary diabetic foot centre. In this series we undertook mid foot corrective fusion in 27 feet (25patients) and are presenting the results of those with a minimumof six months follow up. Twelve of these had concurrent hindfoot fusion. Eleven patients had type 1 diabetes, 12 had type 2 and 2 were non-diabetics. 23 patients were ASA grade3 and 2 were ASA 2. 21 feet had ulcers preoperatively and mean HbA1c was 8.2. 13 patients had diabetic retinopathy and 6 had nephropathy.
Average patient age was 59 (43 to 80) and our mean follow up was 35 months (7 to 67). One patient was lost to follow up and 2 patients died. 18 patients had plates, 3 had bolts and 6 had a combination. Complete follow up data was available for 26 feet in 24 patients. Satisfactory correction of deformity was achieved in all patients. The mean correction of calcaneal pitch was from 0.6 preoperatively to 10.6 degrees postoperatively, mean Meary angle from 22 to 9 degrees, talo- metatarsal angle on AP view from 33 to 13 degree. Bony union was achieved in 21 out of 26 feet and atleast one joint failed to fuse in 5. 19 out of 24 patients were able to mobilize fully or partially weight bearing. We had 6 patients with persisting and 3 withrecurrent ulceration. Seven repeat procedures were carried out which included 2 revision fixations. 4 out of 5 non-unions were seen where bolts were used alone or supplemented with plates.
With our technique and a strict protocol 100% limb salvage and 81% union was achieved. 80% patients were mobile and ulcer healing was achieved in 72%. Corrective mid foot fusion is an effective procedure in these complex casesbut require the input of a multidisciplinary team for perioperative care.
Although there is strong evidence that bisphosphonates prevent certain types of osteoporotic fractures, there are concerns that they may be associated with rare atypical femoral fractures.
1480 patients of proximal femur and shaft fractures over a period of 2 years from Jan 2014 to Jan 2016 were retrospectively reviewed in Gloucestershire Hospitals NHS trust. Hospital trauma database was used.195 patients had fractures in subtrochancteric and femoral shaft area.
11 patients had atypical femur fractures as defined by
Increasing number of patients are on bisphosphonates for osteoporosis. Atypical femur fractures from bisphosphonates are often occult, often bilateral, with delayed healing. Patients on bisphosphonatetreatment should be advised to report any thigh or groin pain. Painful incomplete fractures need treatment with cephalomedullary nailing. Bone biology needs correcting by stopping bisphosphonatesand administering calcium & vitamin D supplements.
Implications: We need to raise awareness amongst treating clinicians and have national guidelines.
Bowel management following joint replacement is often neglected leading lot of patient distress, with the advent of the enhanced orthopedic rehabilitation program, there is a need of a guideline to ensure prompt and quick recovery of bowel habits before discharge. Our aim was to identify the incidence of constipation in joint replacement patients, to evaluate the current practice of bowel management and formulate a protocol for management of constipation to improve the practice. We conducted a prospective study of 50 patients who underwent joint replacement procedures at our institute between September and October 2015. Following initial audit, we formulated a protocol for bowel management, and performed a re-audit by collecting a prospective data of 50 patients. The statistical analysis was done and calculating the mean and standard deviation for continuous variable and Fischer's exact test was used and significance level was set at 0.05. Incidence of constipation was 88% and laxatives were prescribed in 42%. More importantly, there was no correlation between constipation and pre operative fasting (p Value 0.33), post operative fasting (p Value 0.1822), type of surgery (p value 1.00) and type of anaesthesia (p Value 0.27). Following introduction of bowel protocol the laxative prescription increased to 98% (Prophylactic in 81%), consequently the incidence of constipation reduced to 18%. Implementing bowel protocol significantly will improve the patient care and reduce the rate of complications.
The aim of this study is to discuss the results of intramedullary devices in the management of paediatric radial neck fractures and to suggest methods to avoid the pitfalls of the technique.
30 patients with isolated Judet III and IV fractures were included in this retrospective study. The method of reduction was reviewed. The final results were graded using the Metaizeau functional scoring system and Oxford Elbow score.
Intramedullary K wires were used in 10 patients and blunt tipped TENS nails in 20 patients. The complications seen were radiocapitellar joint penetration-6 cases at mean 4.87 weeks, redisplacement − 6, radial epiphyseal sclerosis − 5 and heterotopic ossification − 1 case. The functional result was good to excellent in 24 of 30 cases(80%). The mean Oxford Elbow score was 44.32. The mean follow-up was 40.11 months.
Intramedullary K wires may result in radiocapitellar joint penetration. Blunt tipped devices should not be used as purely fixation devices as they may not prevent redisplacement. Minimal redisplacement does not affect the functional outcome.
Regular follow-up until atleast 6 weeks is essential. Patients who have a Judet IV fracture and need open reduction should be closely followed up and given a guarded prognosis.
Acute Achilles tendon (AT) rupture management remains debatable but non-operative functional regimes are beginning to dominate current treatment algorithms. The aim of this study was to identify predictors of functional outcome in patients with AT ruptures treated non-operatively with an immediate weight bearing functional regime in an orthosis.
Analysis of prospectively gathered data from a local database of all patients treated non-operativelyat our institution with anAT rupture was performed. Inclusion criteria required a completed Achilles Tendon Rupture Score (ATRS) at a minimum of 8 months post rupture. The ATRS score was correlated against age, gender, time following rupture, duration of treatment in a functional orthoses (8- and 11-week regimes) and complications. 236 patients of average age 49.5 years were included.
The mean ATRS on completion of rehabilitation was 74 points. The mean ATRS was significantly lower in the 37 females as compared to the 199 males, 65.8 vs 75.6 (p = 0.013). Age inversely affected ATRS with a Pearsons correlation of −0.2. There was no significant difference in the ATRS score when comparing the two different treatment regime durations. There were 12 episodes of VTE and 4 episodes of re-rupture. The ATRS does not change significantly after 8 months of rupture.
Patients with AT ruptures treated non-operatively with a functional rehabilitation regime demonstrate good function with low re-rupture rates. Increasing age and female gender demonstrate inferior functional outcomes.
The scaphotrapeziotrapezoid (STT) joint is one of the key link joints between the proximal and the distal carpal rows. We assessed the relationship between the scaphotrapezium (STm) andscaphotrapezoid (STd) joints using computerised tomographyand hypothesised the ratio of STm is =/< STd joint due to which, the possibility of failure of trapeziectomy due to metacarpal collapse is insignificant. We reviewed CT scans of wrist joints of 113 eligible patientsfrom our wrist database between 2009 and 2014 for our study. 31 patients were randomised for interobserver correlation. Reformatted multi-planar sequences were analysed. The ratio of theSTm: STdin sagittal and coronal measurementswas evaluated. Interobserver variations were assessed using the Pearson coefficient.
The sex distribution included 68 males and 29 females, 49 left and 64 right wrists. The STm area was larger in 86 (76%) as compared to STd in 27(24%). Average trapezium to trapezoid ratio was 1:1.5. Ratio of area of trapezium: trapezoid joint is 0.30. The anatomic ratio of the STm in the coronal and sagittal planesis 0.3 and that of the STd joint is 0.2. Ratio of the STm: STd in the coronal plane is 0.29. Pearson's coefficient > 0.8.
A small subset of patients undergoing trapeziectomy alonefor stage II- IV carpometacarpal arthritis of the thumb are at risk of impingement of the first metacarpal due to collapse. Our assessment of the anatomical relationship of the STT joint with CT scan proves that although the area the STm joint is generally larger than the STd joint, there is no significant correlation on the whole.
Osseous first ray surgery is a common day case procedure. Patients are often given regional blocks. We sought to find if there is a difference between ankle block and metatarsal block in this group of patients. After ethical approval was granted and power analysis performed, 25 patients were recruited into each arm of the study. These patients were having either an osteotomy or arthrodesis.
All patients had standardised general anaesthesia and received 20mls of 0.5% chirocaine for the blockade. The cohort having the ankle block had infiltration under ultrasound guidance in the anaesthetic room; and the cohort receiving the metatarsal block had infiltration at the end of the procedure. The timings of both the anaesthesia and the operation were recorded for each patient.
Patients scored their pain level at 2, 6 and 24 hours. The amount of post-operative analgesia used in the first 24 hours was also recorded by the research nurse. All patients were discharged home with a standardised prescription of analgesia.
Analysis of the pain scores showed that there was no difference between the two blocks at any measured time period. Nor was there a difference in the analgesic requirement in the first 24 hours. There was, however, a difference in the time taken for the whole procedure: with the ankle block taking an average of ten minutes more.
We conclude that metatarsal blocks are as effective as ankle blocks in providing pain relief after osseous first ray surgery, and may be a more efficient use of time.
Orthopaedics has been earmarked as one of the specialties that could make significant savings in the National Health Service. A large number of young adults are receiving total hip replacements and there has been a trend towards using uncemented implants. We describe the clinical and functional results at minimum 19 year follow up of cemented total hip replacements in patients under the age of fifty-five in our health region between 1990 and 1997.
104 cemented THRs performed in 100 patients under 55 years were included in this study. The follow-up data had been collected prospectively in the University database. 88.46% hips showed good to excellent results at final follow-up with a mean Harris hip score of 87.9±8.64. Revision was performed in 2 hips (1.92%), one for aseptic acetabular loosening and the other for late haematogenous infection. Probable radiological loosening was seen in 14 acetabular components (14.89%) and 4 femoral components (4.25%) at final follow-up. The mean rate of acetabular wear was 0.12mm/year and was not influenced by gender or diagnosis. The mean follow-up was 21.68±2.11 years (range 19 to 26 years) and the survivorship at 19 years was 98.07%.
The GIRFT report looked at the economic aspect of implant selection and found that the cost of uncemented implants was almost double that of the cemented implants. Savings of atleast £10 million a year can be made if cemented implants were used. We recommend that in a publically funded health system like the NHS, cemented implants can be used in patients under 55 with good long term functional outcomes and large savings in the healthcare costs.
Our aim was to compare the biomechanical strength modified side-to-side repair with modified pulvertaft technique keeping overlap length, anchor points, type of suture, suture throw and amount of suture similar.
In our study, we have used turkey tendons. Two investigators performed 34 repairs during one summer month. All mechanical testing was carried out using the tensile load testing machine. Variables measured were maximum load, load to first failure, modulus, load at break, mode of failure, site of failure, tensile strain, and tensile stress. The statistical comparison was carried by Levene's test and T test for means.
The mean maximum load tolerated by modified side-to-side repair was 50.3N(S.D13.7) and that by modified pulvertaft 46.96N(S.D: 16.4), overall it was 48.29 N (S.D: 14.57). The tensile stress at maximum load for modified pulvertaft and modified side-to-side repair was 4.2MPa(S.D: 3.1) and 4.7 MPa (S.D: 3.8) respectively {Overall 4.3MPa(S.D: 3.5)}. The tensile stress at yield was 4.01 MPa (S.D: 3.1) and 5.5 MPa (S.D: 3.7) respectively for modified pulvertaft and modified side-to-side repair {overall 4.44 MPa (S.D: 3.45)}. The tensile strain at maximum load respectively for side-to-side and modified pulvertaft repair was 7.87%(S.D: 33.3) and 7.84%(S.D: 34.02) respectively.
We found no statistical difference between 2 repairs in terms of strength, load to first failure, and maximum load to failure. The suture cut through was the commonest mode of failure.
Our study uniquely compares two techniques under standard conditions, and contrary to existing evidence found no difference.
Chondral defects of the knee are common and often seen in young and active individuals. A novel single stage arthroscopic technique for the treatment of articular cartilage defects in the knee is described. This involves microfracture and application of concentrated bone marrow aspirate cells (BMAC) with fibrin and Hyaluronic Acid as a gel. After a representative preclinical study, the 5 year results of a prospective clinical study are presented.
The pre-clinical study involved two groups of rabbits with standardised lesions treated with microfracture alone and microfracture combined with fibrin/HA/BMAC application. New cartilage from both groups was subjected to staining with H&E for tissue morphology, toluidine blue (collagen) and safranin O (GAG), immunohistochemistry with antibodies for collagen type I and II, and scanning and transmission electron microscopy to analyse the microstructural morphologies. The fibrin/HA/BMAC group scored better than the microfracture group on all tests.
A subsequent prospective clinical study patients (n=60) with symptomatic ICRS grade III/IV chondral defects (lesion size 2–8cm2). The surgical procedure involved debridement of the lesion, micro-fracture and application of fibrin/HA/BMAC gel under CO2 insufflation. Patients underwent morphological evaluation with MRI (T2*-mapping and d-GEMRIC scans). Clinical assessment employed the Lysholm, IKDC and KOOS scores while radiological assessment was performed with MOCART score.
At 5 years, Lysholm score was 78, compared to 51 pre-operatively (p<0.05). KOOS (symptomatic) improved to 90 from 66 (p<0.05). IKDC (subjective) went to 80 from 39 (p<0.05). The mean T2* relaxation-times for the repair tissue and native cartilage were 26 and 29.9 respectively. Average MOCART score for all lesions was 70.
This technique shows encouraging clinical results at 5 year follow-up. The morphological MRI shows good cartilage defect filling and the biochemical MRI suggests hyaline like repair tissue.
We investigated whether an alternative tension band wire technique will produce greater compression and less displacement at olecranon (elbow) fracture sites compared to a standard figure of eight tension band technique. Olecranon fractures are commonly treated with tension band wiring using stainless steel wire in a figure of eight configuration. However recently published studies have raised doubts over the validity of the tension band concept proving that the standard figure of eight configuration does not provide fracture compression when the elbow is flexed. We propose an alternative tension band technique where the figure of eight is applied in a modified configuration producing greater compression across the fracture.
An artificial elbow joint was simulated using artificial forearm (ulna) and arm (humerus) bones. The design simulated the action of the muscles around the elbow joint to produce flexion and extension. There were two arms to this investigation. (1) Standard tension band wire configuration with stainless steel. (2) Modified tension band wire configuration with stainless steel. The simulated elbow was put through a range of movement and sensors measured the compression at the articular and non-articluar surfaces of the fracture. Measurements were taken for compression with different weights applied to challenge both the techniques of tension band wiring.
Measurements from the non articular surface of the fracture demonstrated greater compression with alternative tension band technique. However it was not statistically significant (ANOVA). Compression at the articular surface of the fracture exhibited statistically significant (p<0.05) greater compression with the alternative technique. Neither technique produced greater compression during flexion of the simulated elbow.
The alternative tension band wiring technique proved superior in providing greater compression over the fracture site.