header advert
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Volume 86-B, Issue 4 May 2004

Access Required
C. M. Robinson R. J. Dobson
View article
Download PDF

Access Required
G. S. E. Dowd
View article
Download PDF

B. W. Schreurs S. B. T. Bolder J. W. M. Gardeniers N. Verdonschot T. J. J. H. Slooff R. P. H. Veth
View article
Download PDF

This study presents the clinical and radiological results of 62 consecutive acetabular revisions in 58 patients, at a mean of 16.5 years follow-up (15 to 20). The Kaplan-Meier survivorship for the cup with end-point revisions for any reason, was 79% at 15 years (95% confidence interval (CI); 67 to 91). Excluding two revisions for septic loosening at three and six years, and one revision of a well-fixed cup after 12 years in the course of a femoral revision, the survivorship was 84% at 15 years (95% CI; 73 to 95). At review there were no additional cases of loosening, although seven acetabular reconstructions showed radiolucent lines in one or two zones. Acetabular revision using impacted large morsellised bone chips (0.7 cm to 1.0 cm) and a cemented cup, is a reliable technique of reconstruction, when assessed at more than 15 years.


B. M. Wroblewski P. B. Siney P. A. Fleming
View article
Download PDF

Since wear and loosening of the ultra-high-molecular-weight polyethylene cup are factors which limit the life of an arthroplasty we have attempted to identify factors associated with either low wear (0.02 mm/year or less) or high wear (0.2 mm/year or more). In a series of 1434 Charnley low-friction arthroplasties (1092 patients) 190 (13.2%) showed low wear while 149 (10.4%) showed high wear. We used chi-squared test to assess the significance of various factors.

The significant factors of the low-wear group were female gender (p = 0.042), rheumatoid arthritis (p = 0.014), Charnley grade C (p = 0.03) and varus position of the stem (p = 0.003). The use of acetabular cement pressurisation (p = 0.07) and medialisation of the cup (p = 0.07) approached significance.

In the high-wear group there was a predominance of men (p = 0.042) with osteoarthritis (p = 0.006) as the underlying hip pathology, and the stem in a valgus position (p = 0.023). Support of the cup by the rim of the acetabulum approached significance (p = 0.07). There was no statistical significance between the two groups for revision for aseptic loosening of the stem or fracture of the stem (p = 0.49). There was a highly significant difference (p < 0.0001) between the two groups for revision for wear and aseptic loosening of the cup, 5.3% compared with 39%.

Changes in the cup geometry are probably sufficient to explain the increasing incidence of loosening and revisions with the increasing depth of penetration of the cup. There is much to be gained from the use of a low-wearing ceramic-ultra-high-molecular-weight combination. Tissue reaction to the polyethylene particles cannot be the cause of aseptic loosening of the stem.


S. A. Lie L. I. Havelin O. N. Furnes L. B. Engesæter S. E. Vollset
View article
Download PDF

We present the results for 4762 revision total hip arthroplasties with no previous infection in the hip, which were reported to the Norwegian Arthroplasty Register between 1987 and 2003. The ten-year failure rate for revised prostheses was 26% (95% CI 25 to 26). Cox regression analyses were undertaken separately for acetabular and femoral revision components. Cemented revision components without allograft was the reference category. For acetabular components, we found a significantly reduced risk of failure for uncemented revisions both with (relative risk (RR) = 0.66; 95% CI 0.43 to 0.99) and without (RR = 0.37; 95% CI 0.22 to 0.61) allograft. For femoral components, we found a significantly reduced risk of failure for uncemented revisions, both with (RR = 0.27; 95% CI 0.16 to 0.46) and without (RR = 0.22; 95% CI 0.11 to 0.46) unimpacted allograft. This reduced risk of failure also applied to cemented revision components with allograft (RR = 0.53; 95% CI 0.33 to 0.84) and with impaction bone grafting (RR = 0.34; 95% CI 0.19 to 0.62). Revision prostheses have generally inferior results when compared with primary prostheses. Recementation without allograft, and uncemented revision with bone impaction, were associated with worse results than the other revision techniques which we studied.


Knee
Access Required
J. M. Sikorski
View article
Download PDF

A technique for performing allograft-augmented revision total knee replacement (TKR) using computer assistance is described, on the basis of the results in 14 patients. Bone deficits were made up with impaction grafting. Femoral grafting was made possible by the construction of a retaining wall or dam which allowed pressurisation and retention of the graft. Tibial grafting used a mixture of corticocancellous and morsellised allograft. The position of the implants was monitored by the computer system and adjusted while the cement was setting. The outcome was determined using a six-parameter, quantitative technique (the Perth CT protocol) which measured the alignment of the prosthesis and provided an objective score.

The final outcomes were not perfect with errors being made in femoral rotation and in producing a mismatch between the femoral and tibial components. In spite of the shortcomings the alignments were comparable in accuracy with those after primary TKR. Computer assistance shows considerable promise in producing accurate alignment in revision TKR with bone deficits.


Access Required
N. Adachi M. Ochi Y. Uchio J. Iwasa M. Kuriwaka Y. Ito
View article
Download PDF

A total of 108 patients with unilateral instability of the knee, associated with rupture of the anterior cruciate ligament, was prospectively randomised for arthroscopic single- or double-bundle reconstruction of the ligament using hamstring tendons. The same postoperative rehabilitation protocol was used for all. The patients were followed up for a mean of 32 months (24 to 36). We measured the anterior laxity and joint position sense at different angles of flexion of the knee to determine whether both bundles in the double-bundle reconstruction contributed to the stability of the joint and proprioception.

No significant difference was found between the two groups with regard to anterior laxity measured by the KT-2000 arthrometer with the knee at 20° or 70° flexion nor with regard to proprioception. A notchplasty was required less often in the double- compared with the single-bundle reconstruction.

We did not find any advantage in a double-bundle as opposed to a single-bundle reconstruction in terms of stability or proprioception.


D. Kolker M. Murray M. Wilson
View article
Download PDF

We reviewed, retrospectively, 13 patients who had undergone open anterograde autologous bone grafting of the talus for symptomatic osteochondral defects of the dome of the talus. The mean age of the seven men and six women was 38.4 years. The defects included the full thickness of articular cartilage, extended through the subchondral plate and were associated with subchondral cysts. Six patients (46%) were clinical failures requiring further surgery. Of the remaining seven, functional outcome results were obtained at a mean of 51.9 months after surgery. The mean outcome scores for the Musculoskeletal Outcomes Data Evaluation and Management System foot and ankle questionnaire and the American Orthopaedic Foot and Ankle Society ankle-hindfoot scale were 87.0 and 84.3, respectively. There was an overall 46.2% patient satisfaction rate.

We believe that the technique of autologous bone grafting presented should be used with extreme caution, when considered as the primary treatment for the adult patient with a symptomatic advanced osteochondral defect of the talus.


J. D. F. Calder S. L. Whitehouse T. S. Saxby
View article
Download PDF

The results of treatment of Lisfranc injuries are often unsatisfactory. This retrospective study investigated 46 patients with isolated Lisfranc injuries at a minimum of two years after surgery. Thirteen patients had a poor outcome and had to change employment, or were unable to find work as a result of this injury. The presence of a compensation claim (p = 0.02) and a delay in diagnosis of more than six months were associated with a poor outcome (p = 0.01). There was no association between poor functional outcome and age, gender, mechanism of injury or previous occupation. This study may have medico-legal implications on reporting the prognosis for such injuries, and highlights the importance of prompt diagnosis and treatment.


Upper Limb
Glenothoracic fusion Pages 531 - 535
Access Required
A. Clarke G. Dewnany L. Neumann W. A. Wallace
View article
Download PDF

We describe a surgical procedure used to achieve glenothoracic fusion after one-stage radical, near total scapulectomy for primary or secondary malignant lesions in six patients. The aim was complete excision of the lesion and preservation of the glenoid to provide a fulcrum for movement of the arm.

Post-operative assessment involved determination of the range of movement and the application of the Musculoskeletal Tumour Society score and the Constant score to evaluate function. The results showed that a functional range of movement was attainable despite such radical surgery, although there was a considerable reduction in power and ability to lift.


S. Houshian H. Schrøder R. Weeth
View article
Download PDF

We present our experience with correction of Madelung’s deformity by the Ilizarov technique. Seven patients (eight deformities) were treated by osteotomy of the radius with subsequent lengthening and angular correction. They were reviewed at a mean of 30 months (1.5 to 5.5 years). At the time of operation their mean age was 19 years (9 to 44).

At follow-up all were free from pain and supination had improved by a mean of 34° and pronation by 9°. Flexion had increased in most cases with a median increase of 15°, but only one patient gained further extension. Radial and ulnar deviation were increased by a mean of 6° and 9°, respectively. Radiographic measurements showed that the mean volar angulation had been reduced from 25° to 11°, ulnar inclination from 45° to 30° and carpal malalignment (volar translation) from 7 to 2 mm. The mean lengthening of the radius was 12 mm (6 to 25). All the patients were satisfied with the functional and cosmetic results.


V. J. Takwale J. K. Stanley S. A. Shahane
View article
Download PDF

In 28 patients with a solitary diagnosis of instability of the trapeziometacarpal joint because of a rupture of the anterior oblique ligament, reconstruction was carried out using a slip of the tendon of flexor carpi radialis. We were able to review 26 patients. The results after a follow-up of four years seven months showed that most (87%) had significant relief from pain and symptoms. Seventeen were graded as good to excellent. The mean grip strength recovered to 86% of the contralateral side. Most patients (81%) felt that they had subjective improvement and would have undergone the operation again. A lesser functional result was seen in those who developed a flexion deformity because of overtightening of the reconstruction. Increased awareness of this lesion can lead to an early and clear diagnosis so that the patient may be advised adequately. We describe a specific, diagnostic, clinical test which we have used consistently and successfully.


L. C. L. Ng P. Sell
View article
Download PDF

The optimum timing of lumbar discectomy for sciatica is imprecise. We have investigated a number of prognostic factors in relation to the outcome of radiculopathy after lumbar discectomy. We recruited 113 consecutive patients of whom 103 (91%) were followed up at one year. We found a significant association between the duration of radiculopathy and the changes in the Oswestry Disability Index score (p = 0.005) and the low back outcome score (p = 0.03). Improvement in pain was independent of all variables. Patients with an uncontained herniated disc had a shorter duration of symptoms and a better functional outcome than those with a contained herniation.

Our study suggests that patients with sciatica for more than 12 months have a less favourable outcome. We detected no variation in the results for patients operated on in whom the duration of sciatica was less than 12 months.


W. J. Gaine J. Lim W. Stephenson C. S. B. Galasko
View article
Download PDF

A consecutive series of 85 patients with Duchenne’s muscular dystrophy who underwent spinal fusion over a period of 16 years was followed up with regard to the progression of the scoliosis and pelvic obliquity. Of 74 patients with adequate radiographic follow-up, 55 were instrumented with the Luque single-unit rod system and 19 with the Isola pedicle screw system; seven were instrumented to L3/4, 42 to L5, 15 to S1 and 10 to the pelvis with intrailiac rods.

The mean period of follow-up was 49 months (SD 22) before and 47 months (SD 24) after operation. There was one peri-operative death and three cases of failure of hardware.

The mean improvement in the Cobb angle was 26° and in pelvic obliquity, 9.2°.

Fusion to L3/4 achieved a poorer correction of both curves while intrapelvic rods, achieved and maintained the best correction of pelvic obliquity. Fusion to S1 did not provide any benefit over more proximal fusion excluding the sacrum, with regard to correction and maintenance of both angles. The Isola system appeared to provide and maintain a slightly better correction of the Cobb angle.


M. H. A. Malik P. Harwood P. Diggle S. A. Khan
View article
Download PDF

We report a retrospective study over five years to determine the incidence of infection and nonunion after intramedullary nailing in fractures of 214 long bones; 122 femoral, 75 tibial and 17 humeral. The indications for nailing were trauma (n = 161), pathological fracture (n = 30) and nonunion (n = 23). There were 30 open fractures. The overall rates of deep infection and nonunion were 3.8% and 14.2%, respectively.

Using multiple logistic regression analysis, we determined the relationships between deep infection and nonunion and the pre- and peri-operative factors of age, ASA score, indication for nailing, the use of reaming, the use of antibiotics, whether the fracture was open and the operating time. Open fractures were found to be significantly associated with deep infection. The length of the operation may also affect the outcome. Opening of the fracture at the time of surgery and the ASA score were found to be significantly associated with the development of nonunion after intramedullary nailing.

We have compared our findings with previously published data from large teaching hospital units.


Arthroplasty
Access Required
K. R. Sehat R. L. Evans J. H. Newman
View article
Download PDF

Following total hip arthroplasty (THA) and total knee arthroplasty (TKR) only the ‘visible’ measured blood loss is usually known. This underestimates the ‘true’ total loss, as some loss is ‘hidden’. Correct management of blood loss should take hidden loss into account.

We studied 101 THAs and 101 TKAs (with re-infusion of drained blood). Following THA, the mean total loss was 1510 ml and the hidden loss 471 ml (26%). Following TKA, the mean total loss was 1498 ml. The hidden loss was 765 ml (49%). Obesity made no difference with either operation.

THA involves a small hidden loss, the total loss being 1.3 times that measured. However, following TKA, there may be substantial hidden blood loss due to bleeding into the tissues and residual blood in the joint. The true total loss can be determined by doubling the measured loss.


Y. M. Van der Linden P. D. S. Dijkstra H. M. Kroon J. J. Lok E. M. Noordijk J. W. H. Leer C. A. M. Marijnen
View article
Download PDF

A number of risk factors based upon mostly retrospective surgical data, have been formulated in order to identify impending pathological fractures of the femur from low-risk metastases. We have followed up patients taking part in a randomised trial of radiotherapy, prospectively, in order to determine if these factors were effective in predicting fractures. In 102 patients with 110 femoral lesions, 14 fractures occurred during follow-up. The risk factors studied were increasing pain, the size of the lesion, radiographic appearance, localisation, transverse/axial/circumferential involvement of the cortex and the scoring system of Mirels. Only axial cortical involvement > 30 mm (p = 0.01), and circumferential cortical involvement > 50% (p = 0.03) were predictive of fracture. Mirels’ scoring system was insufficiently specific to predict a fracture (p = 0.36). Our results indicate that most conventional risk factors overestimate the actual occurrence of pathological fractures of the femur. The risk factor of axial cortical involvement provides a simple, objective tool in order to decide which treatment is appropriate.


Children's Orthopaedics
Access Required
E. Ippolito L. Fraracci P. Farsetti M. Di Mario R. Caterini
View article
Download PDF

We performed CT to investigate how treatment may modify the basic skeletal pathology of congenital club foot. Two homogenous groups of patients treated by one of the authors (EI) or under his supervision were studied. The first included 32 patients with 47 club feet reviewed at a mean age of 25 years and treated by manipulation, application of toe-to-groin plaster casts and an extensive posteromedial release. The second included 32 patients with 49 club feet reviewed at a mean age of 19 years and treated by the Ponseti manipulation technique, application of toe-to-groin plaster casts and a limited posterior release.

At follow-up the shape of the subtalar, talonavicular and calcaneocuboid joints was found to be altered in many feet in both groups. This did not appear to be influenced significantly by the type of treatment performed. Correction of the heel varus and the increased declination angle of the neck of the talus was better in the club feet of the second group, whereas reduction of the medial subluxation of the navicular was better in the first. There was a marked increase in the external ankle torsion angle in the first group and a moderate increase of this angle in the second group, in which medial subluxation of the cuboid on the anterior apophysis of the calcaneum was always corrected. Equinus was corrected in both groups but three-dimensional CT reconstruction of the whole foot showed that cavus, supination and adduction deformities were corrected much better in the second group.


Access Required
G. J. C. Myers P. J. Gibbons P. R. Glithero
View article
Download PDF

We identified 25 children (10 girls and 15 boys) who had been treated with single bone intramedullary fixation for diaphyseal fractures of both forearm bones. Their mean age was 10.75 years (4.6 to 15.9). All had a good functional outcome. We conclude that in selected children, single bone intramedullary nailing is a suitable method of treatment for diaphyseal fractures of both bones of the forearm.


T. Wirth L. Stratmann F. Hinrichs
View article
Download PDF

Between 1985 and 1998, 12 331 patients were included in the general neonatal ultrasound hip screening programme for developmental dysplasia of the hip (DDH). Patients who needed treatment (604) were compared with a second group of 73 unscreened children treated conservatively and surgically for DDH.

The incidence of Graf sonographic hip types IIc to IV varied throughout the observation period. Femoral and pelvic osteotomies were almost entirely restricted to the unscreened group of patients. The six to ten per year recorded in the period 1985 to 1990 declined subsequently to three or less per year. The yearly admissions to hospital fell noticeably after six years of screening. Late presentations of DDH were reduced to three or less per year from 1990 to 1994, none between 1995 and 1998 and one or two per year from 2000.

We conclude that general neonatal sonographic hip screening can reduce significantly surgical procedures, hospitalisation and late presentation of DDH.


Access Required
M. Yaniv E. Ezra S. Wientroub E. Segev
View article
Download PDF

A congenital, unilateral, fixed flexion deformity in a neonate was diagnosed as a congenital absence of the knee. A single cartilage mass, with fusion of the lower femoral and upper tibial ossification centres, was demonstrated by imaging studies. This condition has been reported in the literature only once before. Surgery on our patient, which was performed at the age of two years, consisted of separation of the fused cartilaginous anlage and gradual correction of the deformity using an Ilizarov frame.


V. Kapoor B. Theruvil D. J. Warwick M. G. Uglow
View article
Download PDF

We describe a patient with fractures of both bones of the forearm in whom flexible intramedullary nail fixation of the radius alone led to ulnar malunion and a symptomatic distal radio-ulnar joint subluxation. This was successfully treated by ulnar osteotomy.


M. Chadha S. Kumar
View article
Download PDF

We report the case of a young woman who, over a period of five years was diagnosed and treated for a giant-cell tumour of bone, osteomalacia and fluorosis. A review of the literature revealed a correlation between these three diagnoses, the primary pathology being fluorosis and the remaining symptoms being secondary manifestations. It is important to be aware of this association, especially in regions with endemic skeletal fluorosis.


B. Daley A. T. Doherty B. Fairman C. P. Case
View article
Download PDF

Wear debris was extracted from 21 worn hip and knee replacements. Its mutagenic effects were tested on human cells in tissue culture using the micronucleus assay and fluorescent in situ hybridisation.

The extracted wear debris increased the level of micronuclei in a linear dose-dependent manner but with a tenfold difference between samples. The concentration of titanium +/− vanadium and aluminium within the wear debris was linearly related both to the level of centromere-positive micronuclei in tissue culture, indicating an aneuploid event, and to the level of aneuploidy in vivo in peripheral blood lymphocytes. The concentration of cobalt and chromium +/− nickel and molybdenum in the wear debris correlated with the total index of micronuclei in tissue culture, both centromere-positive and centromere-negative i.e. both chromosomal breakage and aneuploidy events.

The results show that wear debris can damage chromosomes in a dose-dependent manner which is specific to the type of metal. The results from studies in vitro correlate with those in vivo and suggest that the wear debris from a worn implant is at least partly responsible for the chromosomal damage which is seen in vivo.


N. Asano T. Yamakazi M. Seto A. Matsumine H. Yoshikawa A. Uchida
View article
Download PDF

We investigated the rates of expression of bone morphogenetic protein-2 (BMP-2) in 29 adult patients with high-grade malignant fibrous histiocytoma of soft tissue, using the BMP-2-specific monoclonal antibody, AbH3b2/17, and found that they ranged from 1.9% to 78.9%. The survival at five years of the groups expressing high (≥30%) and low (< 30%) levels of BMP-2 was 85.7% and 36.3%, respectively. Multivariable analysis showed that only BMP-2 had prognostic significance for continuous disease-free survival and for overall survival (p < 0.05). Our findings indicate that over-expression of BMP-2 in malignant fibrous histiocytoma of soft tissue is the most reliable prognostic indicator of the parameters assessed.


Z. Orhan K. Ozturan A. Guven K. Cam
View article
Download PDF

The effects of extracorporeal shock waves (ESWT) on tendon healing were assessed by observing histological and biomechanical parameters in a rat model of injury to the tendo Achillis. The injury was created by inserting an 18-G needle through tendo Achillis in 48 adult Wistar albino rats. The animals were divided into three groups. The first group received radiation only after the operation. The second received no shock waves and the third had 500 15 KV shocks on the second post-operative day. All the rats were killed on the 21st day after surgery.

Histopathological analysis showed an increase in the number of capillaries and less formation of adhesions in the study group compared with the control group (p = 0.03). A significantly greater force was required to rupture the tendon in the study group (p = 0.028). Our findings suggest a basis for clinical trials using ESWT.


Author’s reply Pages 619 - 620
Access Required
G. BENTLEY
View article
Download PDF

G. KISH L. HANGODY
View article
Download PDF

Author’s reply Pages 620 - 621
Access Required
R. WINDGHAGER
View article
Download PDF

R. SLAPPENDEL R. DIRKSEN G. G. Van HELLEMONDT
View article
Download PDF

F. T. HOAGLUND
View article
Download PDF

Author’s reply Pages 621 - 621
Access Required
YOUNG-HOO KIM
View article
Download PDF

Access Required
R. K. CHOUDHARY H. A. AHMED
View article
Download PDF

Author’s reply Pages 622 - 622
Access Required
C. V. J. MORGAN-HOUGH
View article
Download PDF

Errata
Errata Pages 622 - 622
Access Required
View article
Download PDF

Access Required
Frank Horan
View article
Download PDF

Leslie Klenerman
View article
Download PDF

Peter Lunn
View article
Download PDF