Advertisement for orthosearch.org.uk
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Volume 76-B, Issue 2 March 1994

B Moyen JL Lerat
View article
Download PDF

AW McCaskie PJ Gregg
View article
Download PDF

R Capanna HG Morris D Campanacci M Del Ben M Campanacci
View article
Download PDF

We report the use of the uncemented Kotz modular femur and tibia reconstruction system after 95 distal femoral resections performed from 1983 to 1989. The average follow-up was 51 months; 62 patients had at least 36 months' follow-up and 36 at least 60 months. Complications required reoperation in 55%. The postoperative infection rate was 5% for primary cases, 6% for revision cases, and 43% for revision of previously infected cases. The polyethylene bushes failed in 42% of cases at an average of 64 months postoperatively. Stem breakage occurred in 6% and was associated with the use of narrow stems and extensive quadriceps excision. The radiological results were excellent or good in most cases and were related to the initial screw fixation, but not to age, chemotherapy, length of resection or size of stem. The clinical results were excellent or good in 75%, failure usually being associated with a complication, especially infection.


Access Required
DA Ferrari JD Ferrari J Coumas
View article
Download PDF

Posterolateral instability of the knee is difficult to diagnose and treat. It has been attributed to failure of ligament reconstruction and has been the cause of numerous knee operations. We present a small group of patients who complained of giving way of the knee and who had an increased range of external rotation of the tibia at 90 degrees knee flexion. The patients all had similar symptoms. We describe the standing apprehension test, which was positive in every case. Anterior subluxation of the lateral femoral condyle was detected manually in four patients and confirmed by radiography and MRI in one. The medial knee pain which is often associated with episodes of instability is probably due to stretching of the posteromedial soft tissues and perhaps the saphenous nerve.


DJ Dandy AJ Gray
View article
Download PDF

We describe 129 patients with disabling instability of the knee due to deficiency of the anterior cruciate ligament. They were treated by replacement of the ligament with a Leeds-Keio prosthesis supplemented by an extra-articular MacIntosh lateral substitution reconstruction. After an average period of 71 months a satisfactory outcome was found in only 60% of knees. Nine had required revision because of recurrent instability and the pivot-shift sign had become positive in 40% of patients. In our opinion the long-term results are unsatisfactory when compared with those obtained using a graft from the medial third of the patellar tendon supplemented with a MacIntosh extra-articular tenodesis.


DJ Dandy SS Desai
View article
Download PDF

We studied changes in patellar tendon length after reconstruction of the anterior cruciate ligament using either the medial third of the patellar tendon as a graft (n = 40) or a Leeds-Keio artificial ligament (n = 40). Both types of ligament replacement had been supplemented with a MacIntosh extra-articular lateral substitution. The mean change in length in the tendon graft group was 6% (SD 5.39); in the Leeds-Keio group it was 2.4% (SD 4.93). The change in length was significant in both groups, but shortening was more frequent and more severe in the tendon graft group. There was shortening of 10% or more in 25% of knees after patellar tendon graft and 7.5% after use of a Leeds-Keio prosthesis.


K Fujikawa T Ohtani H Matsumoto BB Seedhom
View article
Download PDF

We describe a new method for the reconstruction of ruptures of the patellar ligament or the quadriceps tendon, using the flexible open-weave polyester Leeds-Keio prosthetic ligament. Of 25 operations performed since 1985, we were able to review 18 patients (19 knees) with a mean follow-up of 3.5 years (3 to 6.5). No patient had required immobilisation of the knee after operation and the average period to return to normal activities without a walking aid was 10.5 weeks. The average range of motion was 146 degrees, and four patients could squat fully in the Japanese style. There was an extension lag (< 10 degrees) in only four patients; eight patients had some patellar crepitus which was mildly painful in three. There were no cases of infection, persistent joint effusion or rerupture of the extensor apparatus.


Access Required
DC Borton MM Stephens
View article
Download PDF

We performed basal chevron metatarsal osteotomy on 32 feet (31 patients) for painful hallux valgus associated with an increased intermetatarsal 1/2 angle (> 12 degrees). Pedobarographic and radiological examinations were done preoperatively and at a minimum of six months postoperatively. The average hallux valgus angle was improved from 40.9 degrees to 19.2 degrees and the intermetatarsal 1/2 angle from 16.5 degrees to 6.8 degrees. The mean angle of declination of the first metatarsal was decreased by 1.4 degrees. The pedobarographs showed a significant reduction in areas sustaining pressure > 5 kg/cm2, an increased total foot contact area and a higher percentage forefoot contact area on heel raise. There was a high level of patient satisfaction with relief of symptoms and improved appearance of the foot.


TE Kilmartin RL Barrington WA Wallace
View article
Download PDF

In a survey of 6000 children between 9 and 10 years of age, 122 were found to have unilateral or bilateral hallux valgus. These children were randomly assigned to no treatment or to the use of a foot orthosis. About three years later 93 again had radiography. The metatarsophalangeal joint angle had increased in both groups but more so in the treated group. During the study, hallux valgus developed in the unaffected feet of children with unilateral deformity, despite the use of the orthosis.


G Cinotti F Postacchini JN Weinstein
View article
Download PDF

We reviewed 25 diabetic (mean age 68 years) and 25 non-diabetic patients (mean age 71 years) who had undergone decompression for lumbar spinal stenosis at a mean of 3.4 years after operation to determine whether diabetes affected the outcome of surgery. The preoperative symptoms were similar in the two groups except that an abrupt onset of symptoms, the presence of night pain and the absence of any posture-related pain relief were recorded only by diabetic patients. Nerve-conduction velocity was slowed in 80% of the diabetic and in 25% of the non-diabetic patients. Peripheral vascular deficiency was diagnosed in 20% of patients with diabetes and in 4% of non-diabetics. The outcome of surgery was similarly successful in the two groups. Mistaken preoperative diagnosis was the cause of failure in three diabetic patients, two with diabetic neuropathy and one with diabetic angiopathy.


K Takata K Takahashi
View article
Download PDF

We evaluated the nerve roots of the cauda equina by CT myelography in 36 patients aged from 11 to 19 years with lumbar disc herniation. On straight-leg-raising tests, six younger patients had isolated hamstring tightness with no sciatica (group A) and 30 had sciatic pain (group B). CT myelography showed that no patient in group A had associated nerve-root swelling, and that the roots were displaced posteriorly, but not compressed. In 21 of the group-B patients, swelling of the nerve roots was confirmed, with compression between the herniated disc and the superior articular process. Our findings suggest that hamstring tightness in these patients may be caused by a different mechanism from that which causes sciatic pain.


S Katoh WS el Masry
View article
Download PDF

We reviewed a series of 53 patients with closed traumatic complete injuries of the cervical spinal cord. They were admitted within two days to a spinal injuries centre, treated conservatively by six weeks of bedrest and skull traction, then mobilised in a neck support for six weeks. Eight patients had temporary neurological deterioration, four spontaneously and four after cervical manipulation; seven of these recovered to the initial neurological level without surgery. Of 40 patients followed for more than 12 months, 19 recovered useful motor power in local muscles which were initially paralysed (zonal recovery); one patient showed distal motor recovery. Zonal recovery did not correlate with the mechanism of skeletal injury or with the degree of residual canal stenosis. Sensory sparing and an initial neurological level higher than the level of skeletal injury were both good prognostic signs for zonal recovery.


JG Wright S Rudicel AR Feinstein
View article
Download PDF

We aimed to assess individual differences in complaints in patients just before total hip replacement (THR) and the importance attached to the relief of each of them. In a pilot study, using open-ended interviews, we identified 16 main complaints, four of which (night pain, unequal leg length and discomfort during sexual and recreational activities) were not included in any of the six hip-rating scales in general use. Each of the 16 complaints was then assessed in 72 patients and rated for severity and the relative importance of relief. From this we calculated a severity-importance rating for each complaint and a patient-specific score for all complaints. The 72 patients had a mean age of 64 years (17 to 92) and 51% were men. The most important reasons for wanting a THR were day pain and walking difficulty, but the complaints mentioned above and not included in standard hip scores were also important. Greater attention to the individual requirements of patients might improve evaluation of the outcome of orthopaedic treatments.


LT Nilsson H Frazen AS Carlsson R Onnerfalt
View article
Download PDF

We made a study of 49 total hip arthroplasties at five years, comparing the Charnley hip score, the Nottingham Health Profile (NHP) score and the appearance on serial radiographs. Each of the three investigations was performed by an independent observer with no knowledge of the results of the other two studies. The eight patients with radiographic signs of prosthetic loosening had significant reductions in function and quality of life as measured by the NHP questionnaire, but no differences in the mean Charnley hip scores. None of the eight patients had clinical signs of prosthetic loosening sufficient to recommend revision of their THR. The NHP is a relatively low-cost method of providing long-term follow-up of THR.


R Alsema R Deutman TJ Mulder
View article
Download PDF

In 1988 we reported a ten-year review of 83 surviving patients from a group of 135 (146 prostheses) who had undergone primary hip replacement using the Stanmore prosthesis. We have now reviewed 44 of these patients at 15 to 16 years. Four patients had undergone revision, but the other 40 were all satisfied with the result of their hip replacement, 36 having little or no pain. Functional activities had decreased, but were still adequate for their average age of 81 years. There had been definite migration of the cup and/or femoral component in three hips, wear of the cup in ten and resorption of the calcar in six. Of the 24 hips inserted with radiopaque cement, eight showed an increase in radiolucent lines at the acetabular interface. The cumulative survival rate of the prosthesis was 91% at 15 to 16 years.


L Neumann KG Freund KH Sorenson
View article
Download PDF

We made a prospective study of 241 Charnley total hip replacements performed between 1968 and 1974. In 1990, we reviewed 92 patients with 103 hips (96.3% of surviving hips) at a mean follow-up of 17.6 years (15 to 20.6) The clinical results were excellent, with Charnley scores of 4 or more for pain in 95% of the patients, for function in 73% and for movement in 93%. Of the whole series, 8.3% had been revised, and Kaplan-Meier survival analysis showed a probability of revision at 20 years of 10.7%. These results are similar to those from the few other series with extended follow-up, and make it difficult to justify the present widespread use of uncemented hip prostheses. It would seem that some aspects of the design of the first-generation Charnley stem were beneficial for long-term survival of the arthroplasty. We found no correlation between the clinical results and radiological loosening on the Harris scale.


GM Ferguson ME Cabanela DM Ilstrup
View article
Download PDF

From 1969 through 1982, 305 hips in 290 patients had total hip arthroplasty for failed femoral intertrochanteric osteotomy. Of these, we reviewed 215 hips (70.5%) with a minimum follow-up of five years. The results were good or excellent in 79%, but there were technical problems at operation in 23% and a total perioperative complication rate of 11.8%. Late complications occurred in 13.1% including seven late infections (3.2%). At a mean follow-up of ten years, 39 hips had been revised (18.1%), there was probable loosening in 19.5% of stems and 12.6% of cups and possible loosening in 11.4% of stems and 7.2% of cups. The cumulative probability of failure at ten years was 20.6%. We recommend that intertrochanteric osteotomy be advised, planned and executed bearing in mind the possible need for a subsequent total hip arthroplasty, and that screws and plates should be routinely removed soon after union of the osteotomy.


TD Owen CG Moran Smith IM Pinder
View article
Download PDF

We reviewed a consecutive series of 241 uncemented, porous-coated anatomic (PCA) hip replacements at an average follow-up of five years (2 to 9). Of these, 32 had failed (13%), 26 at the acetabular component (11%) and six at the femoral component (2%). Acetabular failure was associated with local osteolysis and excessive polyethylene wear in 20 cases: in these histological examination showed giant macrophages incorporating numerous particles of high-density polyethylene. The femoral failures were related to a poor intramedullary fit with subsequent subsidence. Using the recommendation for revision as the end point, the cumulative survival rate for prostheses was 91% at six years (95% CI +/- 6%), 73% (+/- 11%) at seven years, and 57% (+/- 20%) at eight years. The result of uncemented PCA hip replacement is satisfactory up to six years, but then increasing failure of the acetabular component appears to be due to polyethylene wear, leading to osteolysis, loosening and component migration. At first, failure is often asymptomatic; routine follow-up of uncemented hip replacement is essential, especially after five years.


Hernandez EM Keating PM Faris JB Meding MA Ritter
View article
Download PDF

We measured polyethylene wear in 231 porous-coated uncemented acetabular cups. We divided the hips into two groups according to the fixation of the femoral component, by cementing (n = 97) or press-fit (n = 134). Follow-up was from three to five years. The patients in two sub-groups were matched for weight, diagnosis, sex, age and length of follow-up. The linear wear rate of cups articulated with uncemented femoral components (0.22 mm/year) was significantly higher than the wear rate (0.15 mm/year) of cups articulated within cemented femoral components (p < 0.05). These results can be compared with previously reported wear rates of 0.08 mm/year for cemented all-polyethylene cups and 0.11 mm/year for cemented metal-backed cups. The higher wear rates of uncemented arthroplasties could jeopardize the long-term results of this type of hip replacement.


JD Witt CJ McCullough
View article
Download PDF

We report the results of anterior soft-tissue release of the hip for fixed flexion deformity in 17 patients (31 hips) with juvenile chronic arthritis. The mean age at operation was 8 years 6 months. All the patients were reviewed at one and three years and 11 (21 hips) were available for review at five years. The results were good as regards early pain relief and improved mobility. At one year, the average fixed flexion deformity was reduced from 35 degrees to 9.5 degrees, and at three years it was 18 degrees. This degree of improvement was maintained in the hips followed for five years. At 5 to 12 years' follow-up (mean 6.7) seven patients (14 hips) have required no further surgery and have maintained an acceptable range of motion. We discuss the influence of surgery on radiographic changes and on femoral neck anteversion.


Access Required
NM Portinaro SJ Matthews MK Benson
View article
Download PDF

In the first few months of life, a notch may be seen on radiographs of the superolateral margin of the infant hip. It may be associated with a steeply inclined acetabular roof and may be an indicator of persistent neonatal instability or displacement of the femoral head.


A Shah R Asirvatham
View article
Download PDF

We reviewed retrospectively 94 patients who had undergone soft-tissue release to correct flexion contracture of the knee to determine the incidence of postoperative hypertension. The cause of contracture in most patients was cerebral palsy (45) or old poliomyelitis (39). Twenty patients developed persistent hypertension. Two of them were symptomatic, one developing hypertensive encephalopathy. Patients who had had poliomyelitis were at a higher risk than those with cerebral palsy; the risk increased with bilateral procedures. The amount of correction achieved had no influence on the incidence of hypertension.


I Sanpera JA Fixsen RA Hill
View article
Download PDF

We report two cases of deformity of the ankle caused by physeal damage secondary to extravasation of an intravenous infusion in infancy. The possible mechanisms of injury to the physis are discussed.


Access Required
I Hudson A Catterall
View article
Download PDF

We treated 37 infants with 53 idiopathic club feet by posterolateral release alone at a mean age of 2.4 months. They were reviewed after a mean follow-up of 10 years 7 months. Both function and appearance were studied. Seventeen feet had required further surgery, at an average of four years after posterolateral release. In all cases hindfoot equinus had been well corrected; the mean ankle dorsiflexion at review was 15 degrees. Most feet showed subtalar joint movement of between 50% and 75% of normal. Four feet showed poor results: one had a stiff subtalar joint, two feet in one child showed fixed forefoot varus, and one foot had required a Dillwyn-Evans operation at 5.5 years. The overall reoperation rate of 32% at ten years suggests that a radical release operation is not necessary in all patients. Of 59 patients who had only a simple posterolateral release 27 (46%) have satisfactory results.


GM Georgiadis
View article
Download PDF

We report the use of combined anterior and posterior approaches for the reduction and fixation of complex tibial plateau fractures involving a large split posteromedial fragment. In four patients, we used a posterior plate to fix the posteromedial fragment. All fractures united in good position with no significant complications, and all patients had a good range of knee movement. This technique should be considered for complex fractures in which there is a substantial posteromedial fragment (split) component.


J Vanek
View article
Download PDF

We report a case of an apparent avulsion fracture of the posteromedial margin of the medial plateau of the tibia. This was associated with a tear of the medial meniscus and rupture of the anterior cruciate ligament (ACL). This triad has been previously reported, and the plateau fracture was related to the insertion of the semimembranosus tendon. The detailed investigation of our case and some experiments on cadaver knees showed that the injury was not an avulsion fracture but was produced by varus and external rotation forces on a flexed knee. It was due to the anterior subluxation of the medial tibial plateau after rupture of the ACL.


PT Simonian Chapman HS Selznick SK Benirschke BF Claudi MF Swiontkowski
View article
Download PDF

We have reviewed our experience of four iatrogenic femoral neck fractures in 315 consecutive closed intramedullary nailings with the AO/ASIF universal femoral nail. The average neck-shaft angle in the bones that fractured was 139.3 degrees +/- 1.2 degrees SD (136 to 141); in the whole series the average neck-shaft angle was 125.3 degrees +/- 8.6 degrees and only 11 had angles of more than 135 degrees. The upper ends of the nails in the four which fractured were 17 mm, 5 mm, 3 mm, and 1 mm below the tip of the greater trochanter. In the seven patients with neck-shaft angles greater than 135 degrees but with no fracture, none of the nails had been inserted beyond the tip of the greater trochanter. We nailed six cadaver femora to simulate the forces produced by intramedullary nailing. Despite deep insertion, only one of the six sustained a neck fracture. This specimen had a radiographic neck-shaft angle of 140 degrees against an average of 127.3 degrees +/- 4.0 degrees for the other five. We believe that the medial prong of the AO insertion jig, with its medial overhang of 2 to 3 mm, may impinge on the superior aspect of a valgus femoral neck during final impaction, causing a neck fracture. This may be avoided by leaving the end of the nail above the tip of the trochanter in such cases.


SV Skak E Grossmann P Wagn
View article
Download PDF

We reviewed 24 displaced fractures through the physis of the medial epicondyle of the distal humerus. One was a Salter-Harris type-II fracture-separation of the whole distal humeral epiphysis; the others involved only the medial epicondylar centre of ossification. Two cases had presented as pseudarthroses. One fracture had been treated closed in a plaster slab and 21 had had open reduction and internal fixation with sutures, Kirschner wires or Palmer nails. At 2 to 13 years later we found five types of deformity of the epicondyle: pseudarthrosis, an ulnar sulcus, a double-contoured epicondyle, hypoplasia or hyperplasia. Pseudarthrosis had developed after either no treatment, closed reduction and plaster, or open reduction and suturing. Hypoplasia followed nailing, as did a trend to varus tilting of the joint surface. One very young patient, with fracture-separation of the whole distal epiphysis treated by nailing, developed marked cubitus varus.


IJ Langdon PS Kerr RM Atkins
View article
Download PDF

Our previous reports on the pathological anatomy and operative treatment of intra-articular fractures of the calcaneum failed to take account of the fracture pattern anterior to the posterior facet of the subtalar joint. We have reviewed our experience of 63 operative cases and have studied fractures with axial and coronal CT scans reconstructed onto plastic model bones. A constant anterolateral fragment exists, which is displaced by an extended lateral approach to the fracture. If it is unrecognised and unreduced, union in a displaced position may limit hindfoot eversion and disrupt the calcaneocuboid joint. We describe techniques for reduction and fixation of the fragment.


CE Tuson EB Hoffman MD Mann
View article
Download PDF

We prospectively studied 86 children to assess the value and accuracy of isotope bone scanning in the diagnosis of suspected acute haematogenous osteomyelitis and septic arthritis. The patients were scanned because of difficulty in localising the exact site of the pathology. Characteristic scan appearances were found. In osteomyelitis there was increased or decreased uptake extending beyond the confines of the joint capsule; in septic arthritis there was increased or decreased uptake on either side of the joint line, but largely limited to and uniform within the joint capsule. The bone-scan images were correlated with the final diagnosis in 34 sites of septic arthritis and in 62 sites of osteomyelitis. The overall accuracy of the bone scans was 81%. The predictive value for a positive scan to be correct was 100% for a cold scan and 82% for a hot scan. The main reason for a false-positive scan was contiguous soft-tissue infection. The predictive value for a negative scan to be correct was 63%. One reason for a false-negative scan was that the patient was in the transitional phase from cold to hot.


Access Required
CB Howard M Einhorn R Dagan P Yagupski S Porat
View article
Download PDF

In 30 patients in whom osteomyelitis was suspected fine-needle bone biopsies (FNBB) were taken at the same time as bone was aspirated for bacteriological examination. The diagnosis of osteomyelitis was eventually confirmed in 15 patients; the other 15 had myositis (3), arthritis (3), trauma (2), microgeodic phalangeal syndrome (2), haematoma in a non-ossifying fibroma (1), and Ewing's sarcoma (1). In three patients no pathology was found. The temperature, WBC and ESR at presentation did not help to distinguish osteomyelitis from other conditions. FNBB, however, proved to be a useful additional investigation with a sensitivity for osteomyelitis of 87% and a specificity of 93%.


EM Obeid MA Adams JH Newman
View article
Download PDF

We studied the mechanical properties of cartilage from the apparently unaffected compartment of knees with unicompartmental osteoarthritis (OA). Plugs of cartilage and subchondral bone, 8 mm in diameter, were obtained from the tibial plateau of seven patients treated by total knee replacement. Control specimens were obtained from eight cadaver knees of similar age. Specimens were loaded by a plane-ended indentor in a hydraulic materials testing machine; we measured thickness, 'softness', rate of creep, and compressive strength of the articular cartilage. We found that the 'unaffected' cartilage from OA knees was significantly thinner and softer than control cartilage, and it was slightly, although not significantly, weaker. We conclude that the apparently unaffected cartilage in knees with unicompartmental OA is mechanically inferior to normal cartilage, even although clinically, radiologically and morphologically it appears to be sound.


NE Motzkin EY Chao KN An MA Wikenheiser DG Lewallen
View article
Download PDF

We aimed to determine the optimal method of inserting a screw into polymethylmethacrylate (PMMA) cement to enhance fixation. We performed six groups of ten axial pull-out tests with two sizes of screw (3.5 and 4.5 mm AO cortical) and three methods of insertion. Screws were placed into 'fluid' PMMA, into 'solid' PMMA by drilling and tapping, or into 'curing' PMMA with quarter-revolution turns every 30 seconds until the PMMA had hardened. After full hardening, we measured the maximum load to failure for each screw-PMMA construct. We found no significant difference in the pull-out strengths between screw sizes or between screws placed in fluid or solid PMMA. Screws placed in curing PMMA were significantly weaker: the relative strengths of solid, fluid and curing groups were 100%, 97% and 71%, respectively. We recommend the use of either solid or fluid insertion according to the circumstances and the preference of the surgeon.


Tumour calcinosis Pages 324 - 325
Access Required
AS Rai AC Vincenti AW Samuel
View article
Download PDF

SA Majeed
View article
Download PDF

Access Required
S Reher R Rutsaert M Hendrickx P Van Schil
View article
Download PDF

HS Bhende
View article
Download PDF

Access Required
J Vegter JH Bessems
View article
Download PDF

Osteotomy for hallux valgus Pages 333 - 333
Access Required
D Singh
View article
Download PDF

Access Required
Johnson
View article
Download PDF

Access Required
J Dove
View article
Download PDF

Spinal stenosis Pages 335 - 336
Access Required
D Schwartz
View article
Download PDF

Access Required
D Beard J Moser C Crawford
View article
Download PDF

Access Required
JE Risdall CG Johnston
View article
Download PDF

Access Required
AW McCaskie WM Harper PJ Gregg
View article
Download PDF

Access Required
KS Eyres MJ Bell
View article
Download PDF