We present a prospective review of the outcome of 76 Lubinus patellofemoral arthroplasties carried out in 59 patients between 1989 and 1995. At a mean follow-up of 7.5 years, 62 knees in the 48 patients were reviewed; 11 patients (14 knees) had died. None was lost to follow-up. The clinical outcome using the Bristol Knee Scoring system was satisfactory in 45% of the cases. Maltracking of the patella, resulting in lateral tilt, subluxation and polyethylene wear, was the most common complication (32%). Revision surgery was carried out in 21 knees (28%) giving a cumulative survival rate of 65% (confidence interval (CI) 49 to 77) at eight years. The survival rate for revision and moderate pain was 48% (CI 36 to 59) at six years. Progression of arthritis was seen in seven cases (9%). In five of these (6.5%), the symptoms were severe enough to need revision surgery. Due to the high proportion of unsatisfactory results, we have discontinued the use of this prosthesis.
The appearance and the biochemical, cytological and bacteriological findings were studied in synovial fluid obtained from the knees of 72 patients from south-west India. We report a group of 12 patients with 'eosinophilic synovitis'. In these patients, all below the age of 20 years with an acute onset of severe pain in the knee, there was a large effusion with painful limitation of movement. Their blood leucocyte count averaged 11,200 per mm3 with a mild eosinophilia of 6%. Biochemical examination of synovial fluid was normal, but cytology showed an increase in leucocytes ranging from 1200 to 20,500 (mean 9525) with between 75% and 90% of eosinophils in eight patients and 60% to 75% in four. All the patients responded well to a course of diethylcarbamazine.