Abstract
We present a prospective review of the outcome of 76 Lubinus patellofemoral arthroplasties carried out in 59 patients between 1989 and 1995. At a mean follow-up of 7.5 years, 62 knees in the 48 patients were reviewed; 11 patients (14 knees) had died. None was lost to follow-up.
The clinical outcome using the Bristol Knee Scoring system was satisfactory in 45% of the cases. Maltracking of the patella, resulting in lateral tilt, subluxation and polyethylene wear, was the most common complication (32%). Revision surgery was carried out in 21 knees (28%) giving a cumulative survival rate of 65% (confidence interval (CI) 49 to 77) at eight years. The survival rate for revision and moderate pain was 48% (CI 36 to 59) at six years. Progression of arthritis was seen in seven cases (9%). In five of these (6.5%), the symptoms were severe enough to need revision surgery. Due to the high proportion of unsatisfactory results, we have discontinued the use of this prosthesis.