Advertisement for orthosearch.org.uk
Results 1 - 20 of 66
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 525 - 533
1 Jul 1994
Boeree N Clarke N

We report the preliminary results of a continuing prospective evaluation of a screening programme for congenital dislocation of the hip (CDH) which uses ultrasound imaging to provide delayed selective screening to complement neonatal clinical screening. Of 26,952 births in the Southampton district, 1894 infants were referred for secondary screening because of a clinical abnormality or the presence of a predetermined risk category for CDH. Pavlik harness treatment was required for only 118 infants, giving a treatment rate of 4.4 per 1000 births. Of those referred with clinical instability, 35% did not require treatment. Dislocation or subluxation was detected in 17 of 643 infants referred only because they fell within one of three risk categories: breech presentation, foot deformity and family history. All 17 had normal clinical examinations and cases were discovered in each category. Six children presented with CDH after 12 weeks of age, giving a late presentation rate of 0.22 per 1000 births. All had normal clinical examinations within 24 hours of birth and none was in a risk category. Surgery has been required in ten children, giving a surgical treatment rate of 0.37 per 1000 births. We conclude that, in Southampton, delayed selective secondary screening with ultrasound is more effective than clinical screening alone. It targets treatment to those infants who need it, and reveals a number of dislocated and subluxed hips that would otherwise be missed


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 688 - 689
1 Sep 1994
Johnstone A Beggs I


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 999 - 1005
1 Sep 2003
Sharp RJ Wade CM Hennessy MS Saxby TS

We investigated 29 cases, diagnosed clinically as having Morton’s neuroma, who had undergone MRI and ultrasound before a neurectomy. The accuracy with which pre-operative clinical assessment, ultrasound and MRI had correctly diagnosed the presence of a neuroma were compared with one another based on the histology and the clinical outcome.

Clinical assessment was the most sensitive and specific modality. The accuracy of the ultrasound and MRI was similar and dependent on size. Ultrasound was especially inaccurate for small lesions.

There was no correlation between the size of the lesion and either the pre-operative pain score or the change in pain score following surgery.

Reliance on single modality imaging would have led to inaccurate diagnosis in 18 cases and would have only benefited one patient. Even imaging with both modalities failed to meet the predictive values attained by clinical assessment.

There is no requirement for ultrasound or MRI in patients who are thought to have a Morton’s neuroma. Small lesions, < 6 mm in size, are equally able to cause symptoms as larger lesions. Neurectomy provides an excellent clinical outcome in most cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 918 - 921
1 Nov 1994
Warwick D Martin A Glew D Bannister G

We examined ten femoral veins with duplex ultrasound during total hip replacement to demonstrate the operative manoeuvres which cause venous obstruction and to assess prophylactic measures which may overcome it. Exposure of the acetabulum by distraction of the femur with a hook was less likely to occlude flow than retraction with bone levers. Adequate exposure of the femoral shaft by adduction, flexion and either internal or external rotation caused cessation of flow in all cases. In four cases an A-V Impulse System foot pump was activated during periods of stasis. In each case it overcame the obstruction and produced peak velocities which were twice that of the resting state. In five cases, towards the end of the procedure, debris was seen travelling proximally through the femoral vein.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1123 - 1130
1 Oct 2023
Donnan M Anderson N Hoq M Donnan L

Aims

The aim of this study was to investigate the agreement in interpretation of the quality of the paediatric hip ultrasound examination, the reliability of geometric and morphological assessment, and the relationship between these measurements.

Methods

Four investigators evaluated 60 hip ultrasounds and assessed their quality based the standard plane of Graf et al. They measured geometric parameters, described the morphology of the hip, and assigned the Graf grade of dysplasia. They analyzed one self-selected image and one randomly selected image from the ultrasound series, and repeated the process four weeks later. The intra- and interobserver agreement, and correlations between various parameters were analyzed.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 66 - 68
1 Jan 1993
Mahaisavariya B Laupattarakasem W

We describe a method of closed, unlocked nailing for femoral fractures using ultrasound instead of an image intensifier. Radiography was used only to confirm that the guide wire had been passed into the intramedullary canal of both fragments. The method succeeded in 26 of 30 cases. The failures all occurred in fractures which could not be reduced within 20 minutes. The operating time in those nailed successfully with ultrasound control was not different from the time for 30 control cases using conventional methods with an image intensifier.


Bone & Joint 360
Vol. 12, Issue 5 | Pages 42 - 45
1 Oct 2023

The October 2023 Children’s orthopaedics Roundup. 360. looks at: Outcomes of open reduction in children with developmental hip dislocation: a multicentre experience over a decade; A torn discoid lateral meniscus impacts lower-limb alignment regardless of age; Who benefits from allowing the physis to grow in slipped capital femoral epiphysis?; Consensus guidelines on the management of musculoskeletal infection affecting children in the UK; Diagnosis of developmental dysplasia of the hip by ultrasound imaging using deep learning; Outcomes at a mean of 13 years after proximal humeral fracture during adolescence; Clubfeet treated according to Ponseti at four years; Controlled ankle movement boot provides improved outcomes with lower complications than short leg walking cast


Bone & Joint Research
Vol. 10, Issue 12 | Pages 759 - 766
1 Dec 2021
Nicholson JA Oliver WM MacGillivray TJ Robinson CM Simpson AHRW

Aims. The aim of this study was to establish a reliable method for producing 3D reconstruction of sonographic callus. Methods. A cohort of ten closed tibial shaft fractures managed with intramedullary nailing underwent ultrasound scanning at two, six, and 12 weeks post-surgery. Ultrasound capture was performed using infrared tracking technology to map each image to a 3D lattice. Using echo intensity, semi-automated mapping was performed to produce an anatomical 3D representation of the fracture site. Two reviewers independently performed 3D reconstructions and kappa coefficient was used to determine agreement. A further validation study was undertaken with ten reviewers to estimate the clinical application of this imaging technique using the intraclass correlation coefficient (ICC). Results. Nine of the ten patients achieved union at six months. At six weeks, seven patients had bridging callus of ≥ one cortex on the 3D reconstruction and when present all achieved union. Compared to six-week radiographs, no bridging callus was present in any patient. Of the three patients lacking sonographic bridging callus, one went onto a nonunion (77.8% sensitive and 100% specific to predict union). At 12 weeks, nine patients had bridging callus at ≥ one cortex on 3D reconstruction (100%-sensitive and 100%-specific to predict union). Presence of sonographic bridging callus on 3D reconstruction demonstrated excellent reviewer agreement on ICC at 0.87 (95% confidence interval 0.74 to 0.96). Conclusion. 3D fracture reconstruction can be created using multiple ultrasound images in order to evaluate the presence of bridging callus. This imaging modality has the potential to enhance the usability and accuracy of identification of early fracture healing. Cite this article: Bone Joint Res 2021;10(12):759–766


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 10 - 18
1 Jun 2020
Ueyama H Kanemoto N Minoda Y Taniguchi Y Nakamura H

Aims. The aim of this study was to assess the effectiveness of perioperative essential amino acid (EAA) supplementation to prevent rectus femoris muscle atrophy and facilitate early recovery of function after total knee arthroplasty (TKA). Methods. The study involved 60 patients who underwent unilateral TKA for primary knee osteo-arthritis (OA). This was a double-blind, placebo-controlled, randomized control trial with patients randomly allocated to two groups, 30 patients each: the essential amino acid supplementation (9 g daily) and placebo (lactose powder, 9 g daily) groups. Supplementation and placebo were provided from one week before to two weeks after surgery. The area of the rectus femoris muscle were measured by ultrasound imaging one month before surgery and one, two, three, and four weeks postoperatively. The serum albumin level, a visual analogue knee pain score, and mobility were also measured at each time point. The time to recovery of activities of daily living (ADLs) was recorded. Postoperative nutrition and physiotherapy were identical in both groups. Results. The mean relative change from baseline was as follows for the amino acid group: 116% in rectus femoris muscle area (71% to 206%); 95% in serum albumin (80% to 115%) and 39% in VAS pain (0% to 100%) at four weeks after surgery. These values in the placebo group were: 97% in muscle area (68 to 155); 89% in serum albumin (71% to 100%) and 56% in VAS pain four weeks after surgery (0% to 100%). All changes were statistically significant (p < 0.05). The mean time to recovery of ADLs was shorter in the amino acid group compared with the placebo group (p = 0.005). Conclusion. Perioperative essential amino acid supplementation prevents rectus femoris muscle atrophy and accelerates early functional recovery after TKA. Cite this article: Bone Joint J 2020;102-B(6 Supple A):10–18


Bone & Joint Research
Vol. 8, Issue 7 | Pages 304 - 312
1 Jul 2019
Nicholson JA Tsang STJ MacGillivray TJ Perks F Simpson AHRW

Objectives. The aim of this study was to review the current evidence and future application for the role of diagnostic and therapeutic ultrasound in fracture management. Methods. A review of relevant literature was undertaken, including articles indexed in PubMed with keywords “ultrasound” or “sonography” combined with “diagnosis”, “fracture healing”, “impaired fracture healing”, “nonunion”, “microbiology”, and “fracture-related infection”. Results. The use of ultrasound in musculoskeletal medicine has expanded rapidly over the last two decades, but the diagnostic use in fracture management is not routinely practised. Early studies have shown the potential of ultrasound as a valid alternative to radiographs to diagnose common paediatric fractures, to detect occult injuries in adults, and for rapid detection of long bone fractures in the resuscitation setting. Ultrasound has also been shown to be advantageous in the early identification of impaired fracture healing; with the advent of 3D image processing, there is potential for wider adoption. Detection of implant-related infection can be improved by ultrasound mediated sonication of microbiology samples. The use of therapeutic ultrasound to promote union in the management of acute fractures is currently a controversial topic. However, there is strong in vitro evidence that ultrasound can stimulate a biological effect with potential clinical benefit in established nonunions, which supports the need for further investigation. Conclusion. Modern ultrasound image processing has the potential to replace traditional imaging modalities in several areas of trauma practice, particularly in the early prediction of impaired fracture healing. Further understanding of the therapeutic application of ultrasound is required to understand and identify the use in promoting fracture healing. Cite this article: J. A. Nicholson, S. T. J. Tsang, T. J. MacGillivray, F. Perks, A. H. R. W. Simpson. What is the role of ultrasound in fracture management? Diagnosis and therapeutic potential for fractures, delayed unions, and fracture-related infection. Bone Joint Res 2019;8:304–312. DOI: 10.1302/2046-3758.87.BJR-2018-0215.R2


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1533 - 1536
1 Nov 2017
Nie K Rymaruk S Paton RW

Aims. A clicky hip is a common referral for clinical and sonographic screening for developmental dysplasia of the hip (DDH). There is controversy regarding whether it represents a true risk factor for pathological DDH. Therefore a 20-year prospective, longitudinal, observational study was undertaken to assess the relationship between the presence of a neonatal clicky hip and pathological DDH. Patients and Methods. A total of 362 infants from 1997 to 2016 were referred with clicky hips to our ‘one-stop’ paediatric hip screening clinic. Hips were assessed clinically for instability and by ultrasound imaging using a simplified Graf/Harcke classification. Dislocated or dislocatable hips were classified as Graf Type IV hips. Results. The mean age at presentation was 13.8 weeks (12.8 to 14.7). In all 351 out of 362 children (97.0%) had Graf Type I hips (normal) that required no treatment. Nine children (2.5%) had Graf Type II hips but all resolved to Graf Type I hips on follow-up scans. One child (0.3%) had Graf Type III hip dysplasia and one child (0.3%) had an irreducible hip dislocation. The two pathological hips were associated with unilateral limited hip abduction. Mean referrals increased from 12.9 to 23.3 each year (p = 0.002) from the first decade of the study to the second, driven by increasing primary care referrals (5.5 versus 16.7 per year, p < 0.001). Conclusion. Most clicky hips required no treatment other than reassurance to parents. Clicky hips with a normal hip examination should be considered a variant of normal childhood and not a risk factor for DDH. However, an abnormal hip examination including unilateral limited hip abduction should prompt urgent further investigations. Cite this article: Bone Joint J 2017;99-B:1533–6


Bone & Joint Research
Vol. 4, Issue 1 | Pages 1 - 5
1 Jan 2015
Vázquez-Portalatín N Breur GJ Panitch A Goergen CJ

Objective . Dunkin Hartley guinea pigs, a commonly used animal model of osteoarthritis, were used to determine if high frequency ultrasound can ensure intra-articular injections are accurately positioned in the knee joint. Methods. A high-resolution small animal ultrasound system with a 40 MHz transducer was used for image-guided injections. A total of 36 guinea pigs were anaesthetised with isoflurane and placed on a heated stage. Sterile needles were inserted directly into the knee joint medially, while the transducer was placed on the lateral surface, allowing the femur, tibia and fat pad to be visualised in the images. B-mode cine loops were acquired during 100 µl. We assessed our ability to visualise 1) important anatomical landmarks, 2) the needle and 3) anatomical changes due to the injection. . Results. From the ultrasound images, we were able to visualise clearly the movement of anatomical landmarks in 75% of the injections. The majority of these showed separation of the fat pad (67.1%), suggesting the injections were correctly delivered in the joint space. We also observed dorsal joint expansion (23%) and patellar tendon movement (10%) in a smaller subset of injections. Conclusion. The results demonstrate that this image-guided technique can be used to visualise the location of an intra-articular injection in the joints of guinea pigs. Future studies using an ultrasound-guided approach could help improve the injection accuracy in a variety of anatomical locations and animal models, in the hope of developing anti-arthritic therapies. Cite this article: Bone Joint Res 2015;4:1–5


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 889 - 892
1 Jul 2008
Al-Shawi A Badge R Bunker T

We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon using a portable ultrasound scanner in a one-stop clinic. There were 78 full thickness tears which we confirmed by surgery or MRI. Three moderate-size tears were assessed as partial-thickness at ultrasound scan (false negative) giving a sensitivity of 96.2%. One partially torn and two intact cuffs were over-diagnosed as small full-thickness tears by ultrasound scan (false positive) giving a specificity of 95.4%. This gave a positive predictive value of 96.2% and a negative predictive value of 95.4%. Estimation of tear size was more accurate for large and massive tears at 96.5% than for moderate (88.8%) and small tears (91.6%). These results are equivalent to those obtained by several studies undertaken by experienced radiologists. We conclude that ultrasound imaging of the shoulder performed by a sufficiently-trained orthopaedic surgeon is a reliable time-saving practice to identify rotator-cuff integrity


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1264 - 1266
1 Sep 2005
Paton RW Hinduja K Thomas CD

Of the 34 723 infants born between 1 June 1992 and 31 May 2002, the hips of 2578 with clinical instability or at-risk factors for developmental dysplasia of the hip were imaged by ultrasound. Instability of the hip was present in 77 patients, of whom only 24 (31.2%) had an associated risk factor. From the ‘at-risk’ groups, the overall risk of type-III dysplasia, instability and irreducibility was 1:15 when family history, 1:27 when breech delivery and 1:33 when foot deformity were considered as risk factors. Of those hips which were ultrasonographically stable, 88 had type-III dysplasia. A national programme of selective ultrasound screening of at-risk factors for the diagnosis of hip dislocation or instability alone cannot be recommended because of its low predictive value (1:88). However, the incidence of type-III dysplasia and hip dislocation or dislocatability in the groups with clinical instability, family history, breech position and possibly postural foot deformity as risk factors could justify a programme of selective ultrasound imaging


Bone & Joint Open
Vol. 5, Issue 1 | Pages 3 - 8
2 Jan 2024
Husum H Hellfritzsch MB Maimburg RD Møller-Madsen B Henriksen M Lapitskaya N Kold S Rahbek O

Aims

The present study seeks to investigate the correlation of pubofemoral distances (PFD) to α angles, and hip displaceability status, defined as femoral head coverage (FHC) or FHC during manual provocation of the newborn hip < 50%.

Methods

We retrospectively included all newborns referred for ultrasound screening at our institution based on primary risk factor, clinical, and PFD screening. α angles, PFD, FHC, and FHC at follow-up ultrasound for referred newborns were measured and compared using scatter plots, linear regression, paired t-test, and box-plots.


Bone & Joint Open
Vol. 4, Issue 7 | Pages 496 - 506
5 Jul 2023
Theunissen WWES Van der Steen MC Van Veen MR Van Douveren FQMP Witlox MA Tolk JJ

Aims

The aim of this study was to identify the information topics that should be addressed according to the parents of children with developmental dysplasia of the hip (DDH) in the diagnostic and treatment phase during the first year of life. Second, we explored parental recommendations to further optimize the information provision in DDH care.

Methods

A qualitative study with semi-structured interviews was conducted between September and December 2020. A purposive sample of parents of children aged younger than one year, who were treated for DDH with a Pavlik harness, were interviewed until data saturation was achieved. A total of 20 interviews with 22 parents were conducted. Interviews were audio recorded, transcribed verbatim, independently reviewed, and coded into categories and themes.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1252 - 1258
1 Dec 2023
Tanabe H Baba T Ozaki Y Yanagisawa N Homma Y Nagao M Kaneko K Ishijima M

Aims

Lateral femoral cutaneous nerve (LFCN) injury is a potential complication after the direct anterior approach for total hip arthroplasty (DAA-THA). The aim of this study was to determine how the location of the fasciotomy in DAA-THA affects LFCN injury.

Methods

In this trial, 134 patients were randomized into a lateral fasciotomy (n = 67) or a conventional fasciotomy (n = 67) group. This study was a dual-centre, double-blind, prospective randomized controlled two-arm trial with parallel group design and a 1:1 allocation ratio. The primary endpoint was the presence of LFCN injury, which was determined by the presence of numbness, decreased sensation, tingling, jolt-like sensation, or pain over the lateral aspect of the thigh, excluding the surgical scar, using a patient-based questionnaire. The secondary endpoints were patient-reported outcome measures (PROMs) using the Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ), and the Forgotten Joint Score-12 (FJS-12). Assessments were obtained three months after surgery.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 935 - 942
1 Aug 2023
Bradley CS Verma Y Maddock CL Wedge JH Gargan MF Kelley SP

Aims

Brace treatment is the cornerstone of managing developmental dysplasia of the hip (DDH), yet there is a lack of evidence-based treatment protocols, which results in wide variations in practice. To resolve this, we have developed a comprehensive nonoperative treatment protocol conforming to published consensus principles, with well-defined a priori criteria for inclusion and successful treatment.

Methods

This was a single-centre, prospective, longitudinal cohort study of a consecutive series of infants with ultrasound-confirmed DDH who underwent a comprehensive nonoperative brace management protocol in a unified multidisciplinary clinic between January 2012 and December 2016 with five-year follow-up radiographs. The radiological outcomes were acetabular index-lateral edge (AI-L), acetabular index-sourcil (AI-S), centre-edge angle (CEA), acetabular depth ratio (ADR), International Hip Dysplasia Institute (IHDI) grade, and evidence of avascular necrosis (AVN). At five years, each hip was classified as normal (< 1 SD), borderline dysplastic (1 to 2 SDs), or dysplastic (> 2 SDs) based on validated radiological norm-referenced values.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 946 - 952
1 Sep 2023
Dhawan R Young DA Van Eemeren A Shimmin A

Aims

The Birmingham Hip Resurfacing (BHR) arthroplasty has been used as a surgical treatment of coxarthrosis since 1997. We present 20-year results of 234 consecutive BHRs performed in our unit.

Methods

Between 1999 and 2001, there were 217 patients: 142 males (65.4%), mean age 52 years (18 to 68) who had 234 implants (17 bilateral). They had patient-reported outcome measures collected, imaging (radiograph and ultrasound), and serum metal ion assessment. Survivorship analysis was performed using Kaplan-Meier estimates. Revision for any cause was considered as an endpoint for the analysis.


Bone & Joint 360
Vol. 13, Issue 6 | Pages 26 - 29
1 Dec 2024

The December 2024 Wrist & Hand Roundup360 looks at: Variability in thumb ulnar collateral ligament rupture management across the UK: survey insights; Identifying five distinct hand osteoarthritis pain phenotypes highlights the impact of biopsychosocial factors; Long-term outcomes of MAÏA TMC joint prosthesis for osteoarthritis: a possible alternative to trapeziectomy; Diagnostic and management strategies for malignant melanoma of the hand; Early versus delayed surgery for distal radius fractures: comparable outcomes but higher complications in delayed treatment; Perioperative anticoagulant and antiplatelet use does not increase complications in wide-awake hand surgery; Variability in treatment of metacarpal shaft fractures highlights need for standardized care; Low-intensity pulsed ultrasound ineffective in reducing time to union for scaphoid nonunion post-surgery.