Advertisement for orthosearch.org.uk
Results 1 - 20 of 71
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1086 - 1093
1 Oct 2023
Kolin DA Sculco PK Gonzalez Della Valle A Rodriguez JA Ast MP Chalmers BP

Aims. Blood transfusion and postoperative anaemia are complications of total knee arthroplasty (TKA) that are associated with substantial healthcare costs, morbidity, and mortality. There are few data from large datasets on the risk factors for these complications. Methods. We retrospectively reviewed the records of TKA patients from a single tertiary care institution from February 2016 to December 2020. There were a total of 14,901 patients in this cohort with a mean age of 67.9 years (SD 9.2), and 5,575 patients (37.4%) were male. Outcomes included perioperative blood transfusion and postoperative anaemia, defined a priori as haemoglobin level < 10 g/dl measured on the first day postoperatively. In order to establish a preoperative haemoglobin cutoff, we investigated a preoperative haemoglobin level that would limit transfusion likelihood to ≤ 1% (13 g/dl) and postoperative anaemia likelihood to 4.1%. Risk factors were assessed through multivariable Poisson regression modelling with robust error variance. Results. In multivariable analyses, each gram of tranexamic acid reduced transfusion likelihood by 39% (adjusted risk ratio (ARR) 0.61 (95% confidence interval (CI) 0.47 to 0.78)). Risk factors associated with an increased risk of transfusion included operating time (ARR 2.07 (95% CI 1.54 to 2.77)) and drain use (ARR 1.73 (95% CI 1.34 to 2.24)). Conclusion. In this study, we found that increased tranexamic acid dosing, decreased operating time, and decreased drain use may reduce transfusions following TKA. We also established a single preoperative haemoglobin cutoff of 13 g/dl that could help minimize transfusions and reduce postoperative complete blood counts. Cite this article: Bone Joint J 2023;105-B(10):1086–1093


Objectives. Tranexamic acid (TXA) is an antifibrinolytic agent used as a blood-sparing technique in total knee arthroplasty (TKA), and is routinely administered by intravenous (IV) or intra-articular (IA) injection. Recently, a novel method of TXA administration, the combined IV and IA application of TXA, has been applied in TKA. However, the scientific evidence of combined administration of TXA in TKA is still meagre. This meta-analysis aimed to investigate the efficacy and safety of combined IV and IA TXA in patients undergoing TKA. Materials and Methods. A systematic search was carried out in PubMed, the Cochrane Clinical Trial Register (Issue12 2015), Embase, Web of Science and the Chinese Biomedical Database. Only randomised controlled trials (RCT) evaluating the efficacy and safety of combined use TXA in TKA were identified. Two authors independently identified the eligible studies, extracted data and assessed the methodological quality of included studies. Meta-analysis was conducted using Review Manager 5.3 software. Results. A total of ten RCTs (1143 patients) were included in this study. All the included studies were randomised and the quality of included studies still needed improvement. The results indicated that, compared with either placebo or the single-dose TXA (IV or IA) group, the combination of IV and IA TXA group had significantly less total blood loss, hidden blood loss, total drain output, a lower transfusion rate and a lower drop in haemoglobin level. There were no statistically significant differences in complications such as wound infection and deep vein thrombosis between the combination group and the placebo or single-dose TXA group. Conclusions. Compared with placebo or the single-dose TXA, the combined use of IV and IA TXA provided significantly better results with respect to all outcomes related to post-operative blood loss without increasing the risk of thromboembolic complications in TKA. Cite this article: Z. F. Yuan, H. Yin, W. P. Ma, D. L. Xing. The combined effect of administration of intravenous and topical tranexamic acid on blood loss and transfusion rate in total knee arthroplasty: combined tranexamic acid for TKA. Bone Joint Res 2016;5:353–361. DOI: 10.1302/2046-3758.58.BJR-2016-0001.R2


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 133 - 134
1 Nov 2013
Parvizi J Diaz-Ledezma C

Total knee replacement (TKR) is an operation that can be performed with or without the use of a tourniquet. Meta-analyses of the available Level-1 studies have demonstrated that the use of a tourniquet leads to a significant reduction in blood loss. The opponents for use of a tourniquet cite development of complications such as skin bruising, neurovascular injury, and metabolic disturbance as drawbacks. Although there may certainly be reason for concern in arteriopathic patients, there is little evidence that routine use of a tourniquet during TKR results in any of the above complications. The use of a tourniquet, on the other hand, provides a bloodless field that allows the surgeon to perform the procedure with expediency and optimal visualisation. Blood conservation has gained great importance in recent years due to increased understanding of the problems associated with blood transfusion, such as increased surgical site infection (due to immunomodulation effect), increased length of hospital stay and increased cost. Based on the authors’ understanding of the available evidence, the routine use of a tourniquet during TKR is justified as good surgical practice. . Cite this article: Bone Joint J 2013;95-B, Supple A:133–4


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 971 - 976
1 Sep 2023
Bourget-Murray J Piroozfar S Smith C Ellison J Bansal R Sharma R Evaniew N Johnson A Powell JN

Aims. This study aims to determine difference in annual rate of early-onset (≤ 90 days) deep surgical site infection (SSI) following primary total knee arthroplasty (TKA) for osteoarthritis, and to identify risk factors that may be associated with infection. Methods. This is a retrospective population-based cohort study using prospectively collected patient-level data between 1 January 2013 and 1 March 2020. The diagnosis of deep SSI was defined as per the Centers for Disease Control/National Healthcare Safety Network criteria. The Mann-Kendall Trend test was used to detect monotonic trends in annual rates of early-onset deep SSI over time. Multiple logistic regression was used to analyze the effect of different patient, surgical, and healthcare setting factors on the risk of developing a deep SSI within 90 days from surgery for patients with complete data. We also report 90-day mortality. Results. A total of 39,038 patients underwent primary TKA for osteoarthritis during the study period. Of these, 275 patients developed a deep SSI within 90 days of surgery, representing a cumulative incidence of 0.7%. The annual infection rate did not significantly decrease over the seven-year study period (p = 0.162). Overall, 13,885 (35.5%) cases were excluded from the risk analysis due to missing data. Risk factors associated with early-onset deep SSI included male sex, American Society of Anesthesiologists grade ≥ 3, blood transfusion, acute length of stay, and surgeon volume < 30 TKAs/year. Early-onset deep SSI was not associated with increased 90-day mortality. Conclusion. This study establishes a reliable baseline infection rate for early-onset deep SSI after TKA for osteoarthritis using robust Infection Prevention and Control surveillance data, and identifies several potentially modifiable risk factors. Cite this article: Bone Joint J 2023;105-B(9):971–976


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 490 - 497
1 Apr 2016
Maempel JF Wickramasinghe NR Clement ND Brenkel IJ Walmsley PJ

Aims. The pre-operative level of haemoglobin is the strongest predictor of the peri-operative requirement for blood transfusion after total knee arthroplasty (TKA). There are, however, no studies reporting a value that could be considered to be appropriate pre-operatively. . This study aimed to identify threshold pre-operative levels of haemoglobin that would predict the requirement for blood transfusion in patients who undergo TKA. . Patients and Methods. Analysis of receiver operator characteristic (ROC) curves of 2284 consecutive patients undergoing unilateral TKA was used to determine gender specific thresholds predicting peri-operative transfusion with the highest combined sensitivity and specificity (area under ROC curve 0.79 for males; 0.78 for females). Results. Threshold levels of 13.75 g/dl for males and 12.75 g/dl for females were identified. The rates of transfusion in males and females, respectively above these levels were 3.37% and 7.11%, while below these levels, they were 16.13% and 28.17%. Pre-operative anaemia increased the rate of transfusion by 6.38 times in males and 6.27 times in females. Blood transfusion was associated with an increased incidence of early post-operative confusion (odds ratio (OR) = 3.44), cardiac arrhythmia (OR = 5.90), urinary catheterisation (OR = 1.60), the incidence of deep infection (OR = 4.03) and mortality (OR = 2.35) one year post-operatively, and increased length of stay (eight days vs six days, p < 0.001). . Conclusion. Uncorrected low pre-operative levels of haemoglobin put patients at potentially modifiable risk and attempts should be made to correct this before TKA. Target thresholds for the levels of haemoglobin pre-operatively in males and females are proposed. Take home message: Low pre-operative haemoglobin levels put patients at unnecessary risk and should be corrected prior to surgery. Cite this article: Bone Joint J 2016;98-B:490–7


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 135 - 139
1 Nov 2013
Reinhardt KR Osoria H Nam D Alexiades MA Figgie MP Su EP

Blood loss during total knee replacement (TKR) remains a significant concern. In this study, 114 patients underwent TKR, and were divided into two groups based on whether they received a new generation fibrin sealant intra-operatively, or a local infiltration containing adrenaline. Groups were then compared for mean calculated total blood volume (TBV) loss, transfusion rates, and knee range of movement. Mean TBV loss was similar between groups: fibrin sealant mean was 705 ml (281 to 1744), local adrenaline mean was 712 ml (261 to 2308) (p = 0.929). Overall, significantly fewer units of blood were transfused in the fibrin sealant group (seven units) compared with the local adrenaline group (15 units) (p = 0.0479). Per patient transfused, significantly fewer units of blood were transfused in the fibrin sealant group (1.0 units) compared with the local adrenaline group (1.67 units) (p = 0.027), suggesting that the fibrin sealant may reduce the need for multiple unit transfusions. Knee range of movement was similar between groups. From our results, it appears that application of this newer fibrin sealant results in blood loss and transfusion rates that are low and similar to previously applied fibrin sealants. Cite this article: Bone Joint J 2013;95-B, Supple A:135–9


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 635 - 643
1 Apr 2021
Ross LA Keenan OJF Magill M Brennan CM Clement ND Moran M Patton JT Scott CEH

Aims. Debate continues regarding the optimum management of periprosthetic distal femoral fractures (PDFFs). This study aims to determine which operative treatment is associated with the lowest perioperative morbidity and mortality when treating low (Su type II and III) PDFFs comparing lateral locking plate fixation (LLP-ORIF) or distal femoral arthroplasty (DFA). Methods. This was a retrospective cohort study of 60 consecutive unilateral (PDFFs) of Su types II (40/60) and III (20/60) in patients aged ≥ 60 years: 33 underwent LLP-ORIF (mean age 81.3 years (SD 10.5), BMI 26.7 (SD 5.5); 29/33 female); and 27 underwent DFA (mean age 78.8 years (SD 8.3); BMI 26.7 (SD 6.6); 19/27 female). The primary outcome measure was reoperation. Secondary outcomes included perioperative complications, calculated blood loss, transfusion requirements, functional mobility status, length of acute hospital stay, discharge destination and mortality. Kaplan-Meier survival analysis was performed. Cox multivariate regression analysis was performed to identify risk factors for reoperation after LLP-ORIF. Results. Follow-up was at mean 3.8 years (1.0 to 10.4). One-year mortality was 13% (8/60). Reoperation was more common following LLP-ORIF: 7/33 versus 0/27 (p = 0.008). Five-year survival for reoperation was significantly better following DFA; 100% compared to 70.8% (95% confidence interval (CI) 51.8% to 89.8%, p = 0.006). There was no difference for the endpoint mechanical failure (including radiological loosening); ORIF 74.5% (56.3 to 92.7), and DFA 78.2% (52.3 to 100, p = 0.182). Reoperation following LLP-ORIF was independently associated with medial comminution; hazard ratio (HR) 10.7 (1.45 to 79.5, p = 0.020). Anatomical reduction was protective against reoperation; HR 0.11 (0.013 to 0.96, p = 0.046). When inadequately fixed fractures were excluded, there was no difference in five-year survival for either reoperation (p = 0.156) or mechanical failure (p = 0.453). Conclusion. Absolute reoperation rates are higher following LLP fixation of low PDFFs compared to DFA. Where LLP-ORIF was well performed with augmentation of medial comminution, there was no difference in survival compared to DFA. Though necessary in very low fractures, DFA should be used with caution in patients with greater life expectancies due to the risk of longer term aseptic loosening. Cite this article: Bone Joint J 2021;103-B(4):635–643


Bone & Joint Research
Vol. 9, Issue 6 | Pages 322 - 332
1 Jun 2020
Zhao H Yeersheng R Kang X Xia Y Kang P Wang W

Aims. The aim of this study was to examine whether tourniquet use can improve perioperative blood loss, early function recovery, and pain after primary total knee arthroplasty (TKA) in the setting of multiple-dose intravenous tranexamic acid. Methods. This was a prospective, randomized clinical trial including 180 patients undergoing TKA with multiple doses of intravenous tranexamic acid. One group was treated with a tourniquet during the entire procedure, the second group received a tourniquet during cementing, and the third group did not receive a tourniquet. All patients received the same protocol of intravenous tranexamic acid (20 mg/kg) before skin incision, and three and six hours later (10 mg/kg). The primary outcome measure was perioperative blood loss. Secondary outcome measures were creatine kinase (CK), CRP, interleukin-6 (IL-6), visual analogue scale (VAS) pain score, limb swelling ratio, quadriceps strength, straight leg raising, range of motion (ROM), American Knee Society Score (KSS), and adverse events. Results. The mean total blood loss was lowest in the no-tourniquet group at 867.32 ml (SD 201.11), increased in the limited-tourniquet group at 1024.35 ml (SD 176.35), and was highest in the tourniquet group at 1,213.00 ml (SD 211.48). The hidden blood loss was lowest in the no-tourniquet group (both p < 0.001). There was less mean intraoperative blood loss in the tourniquet group (77.48 ml (SD 24.82)) than in the limited-tourniquet group (137.04 ml (SD 26.96)) and the no-tourniquet group (212.99 ml (SD 56.35); both p < 0.001). Patients in the tourniquet group showed significantly higher levels of muscle damage and inflammation biomarkers such as CK, CRP, and IL-6 than the other two groups (p < 0.05). Outcomes for VAS pain scores, limb swelling ratio, quadriceps strength, straight leg raising, ROM, and KSS were significantly better in the no-tourniquet group at three weeks postoperatively (p < 0.05), but there were no significant differences at three months. No significant differences were observed among the three groups with respect to transfusion rate, thrombotic events, or the length of hospital stay. Conclusion. Patients who underwent TKA with multiple doses of intravenous tranexamic acid but without a tourniquet presented lower total blood loss and hidden blood loss, and they showed less postoperative inflammation reaction, less muscle damage, lower VAS pain score, and better early knee function. Our results argue for not using a tourniquet during TKA. Cite this article: Bone Joint Res 2020;9(6):322–332


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 10 - 16
1 Jul 2019
Fillingham YA Darrith B Calkins TE Abdel MP Malkani AL Schwarzkopf R Padgett DE Culvern C Sershon RA Bini S Della Valle CJ

Aims. Tranexamic acid (TXA) is proven to reduce blood loss following total knee arthroplasty (TKA), but there are limited data on the impact of similar dosing regimens in revision TKA. The purpose of this multicentre randomized clinical trial was to determine the optimal regimen to maximize the blood-sparing properties of TXA in revision TKA. Patients and Methods. From six-centres, 233 revision TKAs were randomized to one of four regimens: 1 g of intravenous (IV) TXA given prior to the skin incision, a double-dose regimen of 1 g IV TXA given both prior to skin incision and at time of wound closure, a combination of 1 g IV TXA given prior to skin incision and 1 g of intraoperative topical TXA, or three doses of 1950 mg oral TXA given two hours preoperatively, six hours postoperatively, and on the morning of postoperative day one. Randomization was performed based on the type of revision procedure to ensure equivalent distribution among groups. Power analysis determined that 40 patients per group were necessary to identify a 1 g/dl difference in the reduction of haemoglobin postoperatively between groups with an alpha of 0.05 and power of 0.80. Per-protocol analysis involved regression analysis and two one-sided t-tests for equivalence. Results. In total, one patient withdrew, five did not undergo surgery, 16 were screening failures, and 25 did not receive the assigned treatment, leaving 186 patients for analysis. There was no significant difference in haemoglobin reduction among treatments (2.8 g/dl for single-dose IV TXA, 2.6 g/dl for double-dose IV TXA, 2.6 g/dl for combined IV/topical TXA, 2.9 g/dl for oral TXA; p = 0.38). Similarly, calculated blood loss (p = 0.65) and transfusion rates (p = 0.95) were not significantly different between groups. Equivalence testing assuming a 1 g/dl difference in haemoglobin change as clinically relevant showed that all possible pairings were statistically equivalent. Conclusion. Despite the higher risk of blood loss in revision TKA, all TXA regimens tested had equivalent blood-sparing properties. Surgeons should consider using the lowest effective dose and least costly TXA regimen in revision TKA. Cite this article: Bone Joint J 2019;101-B(Supple 7):10–16


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 77 - 83
1 Jul 2019
James EW Blevins JL Gausden EB Turcan S Denova TA Satalich JR Ranawat AS Warren RF Ranawat AS

Aims. Anterior cruciate ligament (ACL) and multiligament knee (MLK) injuries increase the risk of development of knee osteoarthritis and eventual need for total knee arthroplasty (TKA). There are limited data regarding implant use and outcomes in these patients. The aim of this study was to compare the use of constrained implants and outcomes among patients undergoing TKA with a history of prior knee ligament reconstruction (PKLR) versus a matched cohort of patients undergoing TKA with no history of PKLR. Patients and Methods. Patients with a history of ACL or MLK reconstruction who underwent TKA between 2007 and 2017 were identified in a single-institution registry. There were 223 patients who met inclusion criteria (188 ACL reconstruction patients, 35 MLK reconstruction patients). A matched cohort, also of 223 patients, was identified based on patient age, body mass index (BMI), sex, and year of surgery. There were 144 male patients and 79 female patients in both cohorts. Mean age at the time of TKA was 57.2 years (31 to 88). Mean BMI was 29.7 kg/m. 2. (19.5 to 55.7). Results. There was a significantly higher use of constrained implants among patients with PKLR (76 of 223, 34.1%) compared with the control group (40 of 223, 17.9%; p < 0.001). Subgroup analysis showed a higher use of constrained implants among patients with prior MLK reconstruction (21 of 35, 60.0%) compared with ACL reconstruction (55 of 188, 29.3%; p < 0.001). Removal of hardware was performed in 69.5% of patients with PKLR. Mean operative time (p < 0.001) and tourniquet time (p < 0.001) were longer in patients with PKLR compared with controls. There were no significant differences in rates of deep vein thrombosis, pulmonary embolism, infection, transfusion, postoperative knee range of movement (ROM), or need for revision surgery. There was no significant difference in preoperative or postoperative Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS, JR) scores between groups. Conclusion. Results of this study suggest a history of PKLR results in increased use of constrained implants but no difference in postoperative knee ROM, patient-reported outcomes, or incidence of revision surgery. Cite this article: Bone Joint J 2019;101-B(7 Supple C):77–83


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 201 - 209
1 Feb 2014
Napier RJ Bennett D McConway J Wilson R Sykes AM Doran E O’Brien S Beverland DE

In an initial randomised controlled trial (RCT) we segregated 180 patients to one of two knee positions following total knee replacement (TKR): six hours of knee flexion using either a jig or knee extension. Outcome measures included post-operative blood loss, fall in haemoglobin, blood transfusion requirements, knee range of movement, limb swelling and functional scores. A second RCT consisted of 420 TKR patients randomised to one of three post-operative knee positions: flexion for three or six hours post-operatively, or knee extension. Positioning of the knee in flexion for six hours immediately after surgery significantly reduced blood loss (p = 0.002). There were no significant differences in post-operative range of movement, swelling, pain or outcome scores between the various knee positions in either study. Post-operative knee flexion may offer a simple and cost-effective way to reduce blood loss and transfusion requirements following TKR. We also report a cautionary note regarding the potential risks of prolonged knee flexion for more than six hours observed during clinical practice in the intervening period between the two trials, with 14 of 289 patients (4.7%) reporting lower limb sensory neuropathy at their three-month review. Cite this article: Bone Joint J 2014;96-B:201–9


Bone & Joint Open
Vol. 4, Issue 5 | Pages 338 - 356
10 May 2023
Belt M Robben B Smolders JMH Schreurs BW Hannink G Smulders K

Aims

To map literature on prognostic factors related to outcomes of revision total knee arthroplasty (rTKA), to identify extensively studied factors and to guide future research into what domains need further exploration.

Methods

We performed a systematic literature search in MEDLINE, Embase, and Web of Science. The search string included multiple synonyms of the following keywords: "revision TKA", "outcome" and "prognostic factor". We searched for studies assessing the association between at least one prognostic factor and at least one outcome measure after rTKA surgery. Data on sample size, study design, prognostic factors, outcomes, and the direction of the association was extracted and included in an evidence map.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1025 - 1032
1 Aug 2018
Wang D Wang H Luo Z Meng W Pei F Li Q Zhou Z Zeng W

Aims. The aim of this study was to identify the most effective regimen of multiple doses of oral tranexamic acid (TXA) in achieving maximum reduction of blood loss in total knee arthroplasty (TKA). Patients and Methods. In this randomized controlled trial, 200 patients were randomized to receive a single dose of 2.0 g of TXA orally two hours preoperatively (group A), a single dose of TXA followed by 1.0 g orally three hours postoperatively (group B), a single dose of TXA followed by 1.0 g three and nine hours postoperatively (group C), or a single dose of TXA followed by 1.0 g orally three, nine, and 15 hours postoperatively (group D). All patients followed a routine enhanced-recovery protocol. The primary outcome measure was the total blood loss. Secondary outcome measures were hidden blood loss (HBL), reduction in the level of haemoglobin, the rate of transfusion and adverse events. Results. Groups C (661.1 ml, . sd. 262.4) and D (597.7 ml, . sd. 219.6) had significantly lower mean total blood loss compared with groups A and B. The mean HBL was significantly lower in groups B (699.2 ml), C (533.1 ml) and D (469.9 ml) than in group A (p = 0.006, p < 0.001, and p < 0.001, respectively). Groups C (2.22 ml, . sd. 0.91) and D (2.04 ml, . sd. 0.95) had a lower reduction in the level of haemoglobin than groups A and B. However, there were no differences between groups C and D in relation to the three parameters. Conclusion. The addition of two or three postoperative doses of TXA to one preoperative dose produced a significant reduction in blood loss. The two-dose postoperative regimen is the least necessary regimen for clinical efficacy in primary unilateral TKA. The three-dose regimen produced maximum reduction of blood loss. Cite this article: Bone Joint J 2018;100-B:1025–32


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1209 - 1214
1 Nov 2022
Owen AR Amundson AW Larson DR Duncan CM Smith HM Johnson RL Taunton MJ Pagnano MW Berry DJ Abdel MP

Aims

Spinal anaesthesia has seen increased use in contemporary primary total knee arthroplasties (TKAs). However, controversy exists about the benefits of spinal in comparison to general anaesthesia in primary TKAs. This study aimed to investigate the pain control, length of stay (LOS), and complications associated with spinal versus general anaesthesia in primary TKAs from a single, high-volume academic centre.

Methods

We retrospectively identified 17,690 primary TKAs (13,297 patients) from 2001 to 2016 using our institutional total joint registry, where 52% had general anaesthesia and 48% had spinal anaesthesia. Baseline characteristics were similar between cohorts with a mean age of 68 years (SD 10), 58% female (n = 7,669), and mean BMI of 32 kg/m2 (SD 7). Pain was evaluated using oral morphine equivalents (OMEs) and numerical pain rating scale (NPRS) data. Complications including 30- and 90-day readmissions were studied. Data were analyzed using an inverse probability of treatment weighted model based on propensity score that included many patient and surgical factors. Mean follow-up was seven years (2 to 18).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 932 - 936
1 Jul 2012
Lin P Hsu C Huang C Chen W Wang J

Tranexamic acid (TEA), an inhibitor of fibrinolysis, reduces blood loss after routine total knee replacement (TKR). However, controversy persists regarding the dosage and timing of administration of this drug during surgery. We performed a prospective randomised controlled study to examine the optimum blood-saving effect of TEA in minimally invasive TKR. We randomly assigned 151 patients who underwent unilateral minimally invasive TKR to three groups: 1) a placebo group (50 patients); 2) a one-dose TEA group (52 patients), who received one injection of TEA (10 mg/kg) intra-operatively on deflation of the tourniquet; and 3) a two-dose TEA group (49 patients), who received two injections of TEA (10 mg/kg) given pre-operatively and intra-operatively. Total blood loss was calculated from the maximum loss of haemoglobin. All patients were followed clinically for the presence of venous thromboembolism (VTE). The mean total blood loss was significantly higher in the placebo group than in the other two groups (1222 ml (845 to 2043) versus 1035 ml (397 to 1934) and 986 ml (542 to 1811), respectively (both p < 0.0001)). The mean blood loss was not significantly different between the one- and two-TEA groups (p = 0.148). The mean transfusion rate was higher in the placebo group than in the other two groups (22% versus 3.8% (p = 0.006) and 6.1% (p = 0.041), respectively) and there was no statistically significant difference in the mean transfusion rate between the one- and two-TEA groups (p = 0.672). Only one patient, in the two-dose group, had a radiologically confirmed deep venous thrombosis. Our prospective randomised controlled study showed that one intra-operative injection of TEA is effective for blood conservation after minimally invasive TKR


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1197 - 1200
1 Sep 2013
Zhaoning X Xu Y Shaoqi T Baiqiang H Kang S

A total of 187 patients with primary osteoarthritis (OA) of the knee undergoing total knee replacement (TKR) were randomly divided into two groups, one of which underwent synovectomy. The patients and assessors were blinded to the randomisation both before and after surgery. The duration of surgery, hospitalisation period, concealed bleeding, drainage volume, blood transfusion rate and range of movement of the knee at three days after the operation were analysed. Patients were followed up at four weeks and 12 months after their operation, and a visual analogue score (VAS) for pain, Knee Society score (KSS) and a patellar ballottement test were compared between the groups. The mean amount of concealed bleeding was higher in the synovectomy group compared with the control group (1.24 l (0.08 to 3.28) vs 1.03 l (0.16 to 2.94); p = 0.042), as was the mean drainage volume (0.90 l (0.35 to 1.81) vs 0.81 (0.25 to 1.65); p = 0.030). The mean operating time was also higher in the synovectomy group compared with the controls (1.50 hours (1.34 to 1.75) vs 1.41 hours (1.21 to 1.79); p = 0.006). There were no significant differences in blood transfusion rate (p = 0.882), hospital stay (p = 0.805) or range of movement of the knee (p = 0.413) between the two groups. At four weeks and 12 months post-operatively there were no statistically significant differences in any of the measured parameters. We concluded that synovectomy confers no clinical advantages in TKR for primary OA while subjecting patients to higher levels of bleeding and longer operating times. Cite this article: Bone Joint J 2013;95-B:1197–200


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 152 - 160
1 Feb 2018
Subramanyam KN Khanchandani P Tulajaprasad PV Jaipuria J Mundargi AV

Aims. The aims of this study were to compare the efficacy and safety of intra-articular and intravenous (IV) tranexamic acid (TXA) in controlling perioperative blood loss in total knee arthroplasty (TKA) using a randomized, double-blinded equivalence trial. Patients and Methods. A total of 182 patients aged between 45 and 75 years undergoing unilateral TKA at a tertiary centre were randomized to receive TXA, either 1.5 g intra-articularly after closure of the wound (n = 91) or two doses of 10 mg/kg IV (n = 91). The primary outcome measure was the reduction in the level of haemoglobin (Hb) in the blood on the fifth postoperative day. Secondary outcome measures were the total, visible, and hidden blood losses (TBL, VBL, HBL). We assumed equivalence of the primary outcome in both routes with a margin of ± 0.35gm/dl. Block randomization using computer-generated random numbers was used. The patients and the assessor of outcome were blinded. Results. All patients completed the study. The mean difference in the reduction of the level of Hb between the two groups was -0.0055 gm/dl, with two-sided 95% confidence interval (CI) being -0.29 to 0.27, well within the predefined equivalence margin of ± 0.35gm/dl. The groups were comparable with regard to TBL, VBL, HBL, and complications. No patient needed a blood transfusion. Conclusion. A single intra-articular dose and two IV doses of TXA give equivalent efficacy and safety in the management of blood loss at TKA. Cite this article: Bone Joint J 2018;100-B:152–60


Bone & Joint Open
Vol. 5, Issue 10 | Pages 937 - 943
22 Oct 2024
Gregor RH Hooper GJ Frampton C

Aims

The aim of this study was to determine whether obesity had a detrimental effect on the long-term performance and survival of medial unicompartmental knee arthroplasties (UKAs).

Methods

This study reviewed prospectively collected functional outcome scores and revision rates of all medial UKA patients with recorded BMI performed in Christchurch, New Zealand, from January 2011 to September 2021. Patient-reported outcome measures (PROMs) were the primary outcome of this study, with all-cause revision rate analyzed as a secondary outcome. PROMs were taken preoperatively, at six months, one year, five years, and ten years postoperatively. There were 873 patients who had functional scores recorded at five years and 164 patients had scores recorded at ten years. Further sub-group analysis was performed based on the patient’s BMI. Revision data were available through the New Zealand Joint Registry for 2,323 UKAs performed during this time period.


Bone & Joint Open
Vol. 4, Issue 6 | Pages 399 - 407
1 Jun 2023
Yeramosu T Ahmad W Satpathy J Farrar JM Golladay GJ Patel NK

Aims

To identify variables independently associated with same-day discharge (SDD) of patients following revision total knee arthroplasty (rTKA) and to develop machine learning algorithms to predict suitable candidates for outpatient rTKA.

Methods

Data were obtained from the American College of Surgeons National Quality Improvement Programme (ACS-NSQIP) database from the years 2018 to 2020. Patients with elective, unilateral rTKA procedures and a total hospital length of stay between zero and four days were included. Demographic, preoperative, and intraoperative variables were analyzed. A multivariable logistic regression (MLR) model and various machine learning techniques were compared using area under the curve (AUC), calibration, and decision curve analysis. Important and significant variables were identified from the models.


Bone & Joint Research
Vol. 6, Issue 9 | Pages 535 - 541
1 Sep 2017
Zan P Mol MO Yao JJ Fan L Yang D Liu K Li G

Objectives. The length of the tourniquet time during total knee arthroplasty (TKA) is related to the incidence of post-operative deep vein thrombosis (DVT). Our aim in this study was to investigate the effect of the early release of the tourniquet on the incidence of DVT in patients undergoing TKA. Methods. A total of 200 patients who underwent TKA between November 2015 and November 2016 were prospectively enrolled. The tourniquet was inflated before surgery and released immediately after the introduction of the components (early release group). This group was compared with a retrospective cohort of 200 primary TKAs, in which the tourniquet was released after the dressings had been applied (late release group). The presence of a DVT was detected using bilateral lower limb ultrasonography. Peri-operative clinical and follow-up data were collected for analysis. Results. The incidence of DVT in the early release group (9 of 196, 4.6%) was significantly lower compared with the late release group (24 of 200, 12%; odds ratio (OR) 0.35, 95% confidence interval (CI) 0.16 to 0.78, p = 0.008). The incidence of proximal DVT in the early release group (1 of 196 (0.5%)) was significantly lower than in the late release group (8 of 196, 4%; OR 0.12, 95% CI 0.02 to 0.99, p = 0.020). Although the mean intra-operative blood loss was higher in the early release group, the mean post-operative drainage, total blood loss, transfusion requirements and complications were not significantly different in the two groups. Conclusion. In patients who undergo TKA, releasing the tourniquet early is associated with a decreased incidence of DVT, without increasing the rate of complications. Cite this article: Bone Joint Res 2017;6:535–541