Advertisement for orthosearch.org.uk
Results 1 - 15 of 15
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 396 - 400
1 Mar 2013
Rhee SH Kim J Lee YH Gong HS Lee HJ Baek GH

The purpose of this study was to evaluate the risk of late displacement after the treatment of distal radial fractures with a locking volar plate, and to investigate the clinical and radiological factors that might correlate with re-displacement. From March 2007 to October 2009, 120 of an original cohort of 132 female patients with unstable fractures of the distal radius were treated with a volar locking plate, and were studied over a follow-up period of six months. In the immediate post-operative and final follow-up radiographs, late displacement was evaluated as judged by ulnar variance, radial inclination, and dorsal angulation. We also analysed the correlation of a variety of clinical and radiological factors with re-displacement. Ulnar variance was significantly overcorrected (p < 0.001) while radial inclination and dorsal angulation were undercorrected when compared statistically (p <  0.001) with the unaffected side in the immediate post-operative stage. During follow-up, radial shortening and dorsal angulation progressed statistically, but none had a value beyond the acceptable range. Bone mineral density measured at the proximal femur and the position of the screws in the subchondral region, correlated with slight progressive radial shortening, which was not clinically relevant. Volar locking plating of distal radial fractures is a reliable form of treatment without substantial late displacement. Cite this article: Bone Joint J 2013;95-B:396–400


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1403 - 1409
1 Oct 2010
Pape G Zeifang F Bruckner T Raiss P Rickert M Loew M

Fractures of the proximal humerus can lead to malalignment of the humeral head, necrosis and post-traumatic osteoarthritis. In such cases surface replacement might be a promising option. A total of 28 shoulders with glenohumeral arthritis subsequent to a fracture underwent surface replacement arthroplasty of the humeral head in patients with a mean age of 60 years (35 to 83). On the basis of the inclination of the impacted head, post-traumatic arthritis was divided into three types: type 1, an impacted fracture of the head in an anatomical position (seven cases); type 2, a valgus impacted fracture (13 cases); type 3, a varus impacted fracture (eight cases). The outcome was measured by means of the Constant score. According to the Boileau classification of the sequelae of fractures of the proximal humerus, all 28 patients had a final result of intra-capsular category 1. The mean Constant score for the 28 shoulders increased from 23.2 points (2 to 45) pre-operatively to 55.1 points (20 to 89) at a mean of 31 months (24 to 66) post-operatively. Valgus impacted fractures had significantly better results (p < 0.039). Surface replacement arthroplasty can provide good results for patients with post-traumatic osteoarthritis of the shoulder. Their use avoids post-operative complications of the humeral shaft, such as peri-prosthetic fractures. Further surgery can be undertaken more easily as the bone stock is preserved


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 538 - 544
1 May 2003
Ericson A Arndt A Stark A Wretenberg P Lundberg A

We analysed the axis of movement in the normal elbow during flexion in vivo using radiostereometric analysis (RSA). The results show an intraindividual variation in the inclination of the axis ranging from 2.1° to 14.3° in the frontal and from 1.6° to 9.8° in the horizontal plane analysed at 30° increments. The inclination of the mean axis of rotation varied within a range of 12.7° in the frontal and 4.6° in the horizontal plane. In both planes, the mean axes were located close to a line joining the centres of the trochlea and capitellum. The intra- and interindividual variations of the axes of flexion of the elbow were greater than previously reported. These factors should be considered in the development of elbow prostheses


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 935 - 941
1 Jul 2013
Moor BK Bouaicha S Rothenfluh DA Sukthankar A Gerber C

We hypothesised that a large acromial cover with an upwardly tilted glenoid fossa would be associated with degenerative rotator cuff tears (RCTs), and conversely, that a short acromion with an inferiorly inclined glenoid would be associated with glenohumeral osteoarthritis (OA). This hypothesis was tested using a new radiological parameter, the critical shoulder angle (CSA), which combines the measurements of inclination of the glenoid and the lateral extension of the acromion (the acromion index). The CSA was measured on standardised radiographs of three groups: 1) a control group of 94 asymptomatic shoulders with normal rotator cuffs and no OA; 2) a group of 102 shoulders with MRI-documented full-thickness RCTs without OA; and 3) a group of 102 shoulders with primary OA and no RCTs noted during total shoulder replacement. The mean CSA was 33.1° (26.8° to 38.6°) in the control group, 38.0° (29.5° to 43.5°) in the RCT group and 28.1° (18.6° to 35.8°) in the OA group. Of patients with a CSA > 35°, 84% were in the RCT group and of those with a CSA < 30°, 93% were in the OA group. We therefore concluded that primary glenohumeral OA is associated with significantly smaller degenerative RCTs with significantly larger CSAs than asymptomatic shoulders without these pathologies. These findings suggest that individual quantitative anatomy may imply biomechanics that are likely to induce specific types of degenerative joint disorders. Cite this article: Bone Joint J 2013;95-B:935–41


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 536 - 540
1 May 2004
Houshian S Schrøder H Weeth R

We present our experience with correction of Madelung’s deformity by the Ilizarov technique. Seven patients (eight deformities) were treated by osteotomy of the radius with subsequent lengthening and angular correction. They were reviewed at a mean of 30 months (1.5 to 5.5 years). At the time of operation their mean age was 19 years (9 to 44). At follow-up all were free from pain and supination had improved by a mean of 34° and pronation by 9°. Flexion had increased in most cases with a median increase of 15°, but only one patient gained further extension. Radial and ulnar deviation were increased by a mean of 6° and 9°, respectively. Radiographic measurements showed that the mean volar angulation had been reduced from 25° to 11°, ulnar inclination from 45° to 30° and carpal malalignment (volar translation) from 7 to 2 mm. The mean lengthening of the radius was 12 mm (6 to 25). All the patients were satisfied with the functional and cosmetic results


Bone & Joint Research
Vol. 7, Issue 6 | Pages 422 - 429
1 Jun 2018
Acklin YP Zderic I Inzana JA Grechenig S Schwyn R Richards RG Gueorguiev B

Aims

Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically.

Methods

Eight pairs of three-part humeral fractures were randomly assigned for pairwise instrumentation using either a prototype gliding plate or a standard PHILOS plate, and four pairs were fixed using the gliding plate with bone cement augmentation of its proximal screws. The specimens were cyclically tested under progressively increasing loading until perforation of a screw. Telescoping of a screw, varus tilting and screw migration were recorded using optical motion tracking.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1090 - 1096
1 Aug 2012
Mahmoud M El Shafie S Kamal M

Malunion is the most common complication of the distal radius with many modalities of treatment available for such a problem. The use of bone grafting after an osteotomy is still recommended by most authors. We hypothesised that bone grafting is not required; fixing the corrected construct with a volar locked plate helps maintain the alignment, while metaphyseal defect fills by itself. Prospectively, we performed the procedure on 30 malunited dorsally-angulated radii using fixed angle volar locked plates without bone grafting. At the final follow-up, 22 wrists were available. Radiological evidence of union, correction of the deformity, clinical and functional improvement was achieved in all cases. Without the use of bone grafting, corrective open wedge osteotomy fixed by a volar locked plate provides a high rate of union and satisfactory functional outcomes.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1615 - 1619
1 Dec 2007
Piskin A Tomak Y Sen C Tomak L

Cubitus varus and valgus are the most common complications of supracondylar and lateral condylar fractures. Various combinations of osteotomy and fixation have been described to correct these deformities but each is associated with significant complications. In this study, we used distraction osteogenesis and Ilizarov frame fixation to treat 24 elbows in 23 patients with cubitus varus or valgus. Their clinical outcome was evaluated using the protocol of Bellemore et al. The mean time to follow-up was 18.3 months (10 to 36) and the mean time to frame removal was 13.5 weeks (8 to 20). The mean carrying angle was corrected from −18.7° (−10° to −30°) to 6.1° (2° to 10°) in patients with cubitus varus and from 36.5° (25° to 45°) to 9.4° (4° to 15°) in patients with cubitus valgus. There were 18 excellent and six good results.

The Ilizarov method with gradual distraction is a safe, stable, adjustable and versatile method of treating deformities at the elbow without the problems of an unsightly scar or limited range of movement, and gives a good clinical and radiological outcome. Tardy ulnar nerve palsy should be treated first by anterior transposition.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1240 - 1246
1 Sep 2011
Melis B DeFranco M Lädermann A Molé D Favard L Nérot C Maynou C Walch G

Radiological changes and differences between cemented and uncemented components of Grammont reverse shoulder arthroplasties (DePuy) were analysed at a mean follow-up of 9.6 years (8 to 12). Of 122 reverse shoulder arthroplasties implanted in five shoulder centres between 1993 and 2000, a total of 68 (65 patients) were available for study. The indications for reversed shoulder arthroplasty were cuff tear arthropathy in 48 shoulders, revision of shoulder prostheses of various types in 11 and massive cuff tear in nine. The development of scapular notching, bony scapular spur formation, heterotopic ossification, glenoid and humeral radiolucencies, stem subsidence, radiological signs of stress shielding and resorption of the tuberosities were assessed on standardised true anteroposterior and axillary radiographs.

A scapular notch was observed in 60 shoulders (88%) and was associated with the superolateral approach (p = 0.009). Glenoid radiolucency was present in 11 (16%), bony scapular spur and/or ossifications in 51 (75%), and subsidence of the stem and humeral radiolucency in more than three zones were present in three (8.8%) and in four (11.8%) of 34 cemented components, respectively, and in one (2.9%) and two (5.9%) of 34 uncemented components, respectively. Radiological signs of stress shielding were significantly more frequent with uncemented components (p < 0.001), as was resorption of the greater (p < 0.001) and lesser tuberosities (p = 0.009).


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 345 - 350
1 Mar 2006
Loew M Heitkemper S Parsch D Schneider S Rickert M

We reviewed 39 patients with displaced three- and four-part fractures of the humerus. In 21 patients (group A) we had used an anatomical prosthesis for the humeral head and in 18 (group B) an implant designed for fractures.

When followed up at a mean of 29.3 months after surgery the overall Constant score was 51.9 points; in group A it was 51.5 and in group B 52.4 points. The subjective satisfaction of the patients was assessed using a numerical rating scale and was similar in both groups. In group A complete healing of the tuberosities was found in 29% and 50% in group B. Partial integration was seen in 29% of group A and in only one patient in group B, while resorption was noted in 43% of group A and 44% of group B. The functional outcome was significantly better in patients with complete or partial healing of the tuberosities (p = 0.022). The specific trauma prosthesis did not lead to better healing of the tuberosities. The difference in clinical outcome obtained by the two designs did not reach statistical significance.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 210 - 216
1 Feb 2011
Young A Walch G Boileau P Favard L Gohlke F Loew M Molé D

We report the long-term clinical and radiological outcomes of the Aequalis total shoulder replacement with a cemented all-polyethylene flat-back keeled glenoid component implanted for primary osteoarthritis between 1991 and 2003 in nine European centres. A total of 226 shoulders in 210 patients were retrospectively reviewed at a mean of 122.7 months (61 to 219) or at revision. Clinical outcome was assessed using the Constant score, patient satisfaction score and range of movement. Kaplan-Meier survivorship analysis was performed with glenoid revision for loosening and radiological glenoid loosening (sd) as endpoints. The Constant score was found to improve from a mean of 26.8 (sd 10.3) pre-operatively to 57.6 (sd 20.0) post-operatively (p < 0.001). Active forward flexion improved from a mean of 85.3° (sd 27.4) pre-operatively to 125° (sd 37.3) postoperatively (p < 0.001). External rotation improved from a mean of 7° (sd 6.5) pre-operatively to 30.3° (sd 21.8°) post-operatively (p < 0.001). Survivorship with revision of the glenoid component as the endpoint was 99.1% at five years, 94.5% at ten years and 79.4% at 15 years. Survivorship with radiological loosening as the endpoint was 99.1% at five years, 80.3% at ten years and 33.6% at 15 years.

Younger patient age and the curettage technique for glenoid preparation correlated with loosening. The rate of glenoid revision and radiological loosening increased with duration of follow-up, but not until a follow-up of five years. Therefore, we recommend that future studies reporting radiological outcomes of new glenoid designs should report follow-up of at least five to ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 764 - 769
1 Jun 2008
Raiss P Aldinger PR Kasten P Rickert M Loew M

Our aim in this prospective study was to evaluate the outcome of total shoulder replacement in the treatment of young and middle-aged active patients with primary glenohumeral osteoarthritis. We reviewed 21 patients (21 shoulders) with a mean age of 55 years (37 to 60). The mean follow-up was seven years (5 to 9). The same anatomical, third-generation, cemented implant had been used in all patients. All the patients were evaluated radiologically and clinically using the Constant and Murley score.

No patients required revision. In one a tear of the supraspinatus tendon occurred. Overall, 20 patients (95%) were either very satisfied (n = 18) or satisfied (n = 2) with the outcome. Significant differences (p < 0.0001) were found for all categories of the Constant and Murley score pre- and post-operatively. The mean Constant and Murley score increased from 24.1 points (10 to 45) to 64.5 points (39 to 93), and the relative score from 30.4% (11% to 50%) to 83% (54% to 116%). No clinical or radiological signs of loosening of the implant were seen.

For young and middle-aged patients with osteoarthritis, third-generation total shoulder replacement is a viable method of treatment with a low rate of complications and excellent results in the mid-term.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 490 - 494
1 Apr 2007
Arimitsu S Murase T Hashimoto J Oka K Sugamoto K Yoshikawa H Moritomo H

We have measured the three-dimensional patterns of carpal deformity in 20 wrists in 20 rheumatoid patients in which the carpal bones were shifted ulnarwards on plain radiography. Three-dimensional bone models of the carpus and radius were created by computerised tomography with the wrist in the neutral position. The location of the centroids and rotational angle of each carpal bone relative to the radius were calculated and compared with those of ten normal wrists.

In the radiocarpal joint, the proximal row was flexed and the centroids of all carpal bones translocated in an ulnar, proximal and volar direction with loss of congruity. In the midcarpal joint, the distal row was extended and congruity generally well preserved. These findings may facilitate more positive use of radiocarpal fusion alone for the deformed rheumatoid wrist.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1620 - 1626
1 Dec 2007
Toma CD Machacek P Bitzan P Assadian O Trieb K Wanivenhaus A

We retrospectively compared wrist arthrodesis using the Mannerfelt technique in 19 or an AO-plate in 23 patients with long-standing rheumatoid arthritis. The mean follow-up was for 76 months.

Compared with the Mannerfelt fusion group, patients in the AO-plate group reported greater satisfaction with their wrist function (74% vs 37%, p = 0.015). Complications were reported in six wrists in the AO-plate group and two wrists in the Mannerfelt fusion group (p = 0.258). At final follow-up, 95% of patients (41) reported either no pain or only mild pain. There was improvement in flexion of the finger joints in both groups but no significant improvement in the extension lag in either group.

Both methods relieve pain and improve function. Overall, the activities of daily living scores and the patients’ subjective assessment of outcome tended to be higher in the AO-plate group than in the Mannerfelt fusion group, although the difference was not statistically significant. Similarly, although more postoperative complications occurred in the AO-plate group, the difference between the two groups was not statistically significant.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 213 - 219
1 Feb 2006
Kambhampati SBS Birch R Cobiella C Chen L

We describe the results of surgical treatment in a prospective study of 183 consecutive cases of subluxation (101) and dislocation (82) of the shoulder secondary to obstetric brachial plexus palsy between 1995 and 2000. Neurological recovery was rated ‘good’ or ‘useful’ in all children, whose lesions fell into groups 1, 2 or 3 of the Narakas classification. The mean age at operation was 47 months (3 to 204). The mean follow-up was 40 months (24 to 124).

The mean gain in function was 3.6 levels (9.4 to 13) using the Mallet score and 2 (2.1 to 4.1) on the Gilbert score. The mean active global range of shoulder movement was increased by 73°; the mean range of active lateral rotation by 58° and that of supination of the forearm by 51°. Active medial rotation was decreased by a mean of 10°. There were 20 failures. The functional outcome is related to the severity of the neurological lesion, the duration of the dislocation and onset of deformity.