Aims. Proper preoperative planning benefits fracture reduction, fixation, and stability in
Aims.
Aims. To investigate health-related quality of life (HRQoL) of older adults (aged ≥ 60 years) after
Aims. The aim of this study was to determine the trajectory of recovery following fixation of
Aims. Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of
Radiological evidence of post-traumatic osteoarthritis
(PTOA) after fracture of the tibial plateau is common but end-stage arthritis
which requires total knee arthroplasty is much rarer. The aim of this study was to examine the indications for, and
outcomes of, total knee arthroplasty after fracture of the tibial
plateau and to compare this with an age and gender-matched cohort
of TKAs carried out for primary osteoarthritis. Between 1997 and 2011, 31 consecutive patients (23 women, eight
men) with a mean age of 65 years (40 to 89) underwent TKA at a mean
of 24 months (2 to 124) after a fracture of the tibial plateau.
Of these, 24 had undergone ORIF and seven had been treated non-operatively.
Patients were assessed pre-operatively and at 6, 12 and >
60 months
using the Short Form-12, Oxford Knee Score and a patient satisfaction
score. Patients with instability or nonunion needed total knee arthroplasty
earlier (14 and 13.3 months post-injury) than those with intra-articular
malunion (50 months, p <
0.001). Primary cruciate-retaining implants
were used in 27 (87%) patients. Complication rates were higher in
the PTOA cohort and included wound complications (13% Total knee arthroplasty undertaken after fracture of the tibial
plateau has a higher rate of complications than that undertaken
for primary osteoarthritis, but patient-reported outcomes and satisfaction
are comparable. Cite this article:
Bicondylar
This is a multicentre, prospective assessment of a proportion of the overall orthopaedic trauma caseload of the UK. It investigates theatre capacity, cancellations, and time to surgery in a group of hospitals that is representative of the wider population. It identifies barriers to effective practice and will inform system improvements. Data capture was by collaborative approach. Patients undergoing procedures from 22 August 2022 and operated on before 31 October 2022 were included. Arm one captured weekly caseload and theatre capacity. Arm two concerned patient and injury demographics, and time to surgery for specific injury groups.Aims
Methods
The purpose of this study was to determine the weightbearing practice of operatively managed fragility fractures in the setting of publically funded health services in the UK and Ireland. The Fragility Fracture Postoperative Mobilisation (FFPOM) multicentre audit included all patients aged 60 years and older undergoing surgery for a fragility fracture of the lower limb between 1 January 2019 and 30 June 2019, and 1 February 2021 and 14 March 2021. Fractures arising from high-energy transfer trauma, patients with multiple injuries, and those associated with metastatic deposits or infection were excluded. We analyzed this patient cohort to determine adherence to the British Orthopaedic Association Standard, “all surgery in the frail patient should be performed to allow full weight-bearing for activities required for daily livingAims
Methods
Unstable bicondylar tibial plateau fractures
are rare and there is little guidance in the literature as to the
best form of treatment. We examined the short- to medium-term outcome
of this injury in a consecutive series of patients presenting to
two trauma centres. Between December 2005 and May 2010, a total
of 55 fractures in 54 patients were treated by fixation, 34 with
peri-articular locking plates and 21 with limited access direct
internal fixation in combination with circular external fixation
using a Taylor Spatial Frame (TSF). At a minimum of one year post-operatively,
patient-reported outcome measures including the WOMAC index and
SF-36 scores showed functional deficits, although there was no significant
difference between the two forms of treatment. Despite low outcome scores,
patients were generally satisfied with the outcome. We achieved
good clinical and radiological outcomes, with low rates of complication.
In total, only three patients (5%) had collapse of the joint of
>
4 mm, and metaphysis to diaphysis angulation of greater than 5º,
and five patients (9%) with displacement of >
4 mm. All patients
in our study went on to achieve full union. This study highlights the serious nature of this injury and generally
poor patient-reported outcome measures following surgery, despite
treatment by experienced surgeons using modern surgical techniques.
Our findings suggest that treatment of complex bicondylar tibial
plateau fractures with either a locking plate or a TSF gives similar
clinical and radiological outcomes. Cite this article:
The aim of this study was to evaluate near-infrared spectroscopy
(NIRS) as a continuous, non-invasive monitor for acute compartment
syndrome (ACS). NIRS sensors were placed on 86 patients with, and 23 without
(controls), severe leg injury. NIRS values were recorded for up
to 48 hours. Longitudinal data were analyzed using summary and graphical
methods, bivariate comparisons, and multivariable multilevel modelling.Aims
Patients and Methods
A total of 20 patients with a depressed fracture
of the lateral tibial plateau (Schatzker II or III) who would undergo open
reduction and internal fixation were randomised to have the metaphyseal
void in the bone filled with either porous titanium granules or
autograft bone. Radiographs were undertaken within one week, after
six weeks, three months, six months, and after 12 months. The primary outcome measure was recurrent depression of the joint
surface: a secondary outcome was the duration of surgery. The risk of recurrent depression of the joint surface was lower
(p <
0.001) and the operating time less (p <
0.002) when titanium
granules were used. The indication is that it is therefore beneficial to use porous
titanium granules than autograft bone to fill the void created by
reducing a depressed fracture of the lateral tibial plateau. There
is no donor site morbidity, the operating time is shorter and the
risk of recurrent depression of the articular surface is less. Cite this article:
We investigated the stability of seven Schatzker type II fractures of the lateral tibial plateau treated by subchondral screws and a buttress plate followed by immediate partial weight-bearing. In order to assess the stability of the fracture, weight-bearing inducible displacements of the fracture fragments and their migration over a one-year period were measured by differentially loaded radiostereometric analysis and standard radiostereometric analysis, respectively. The mean inducible craniocaudal fracture fragment displacements measured −0.30 mm (−0.73 to 0.02) at two weeks and 0.00 mm (−0.12 to 0.15) at 52 weeks. All inducible displacements were elastic in nature under all loads at each examination during follow-up. At one year, the mean craniocaudal migration of the fracture fragments was −0.34 mm (−1.64 to 1.51). Using radiostereometric methods, this case series has shown that in the Schatzker type II fractures investigated, internal fixation with subchondral screws and a buttress plate provided adequate stability to allow immediate post-operative partial weight-bearing, without harmful consequences.
We reviewed 59 bone graft substitutes marketed
by 17 companies currently available for implantation in the United Kingdom,
with the aim of assessing the peer-reviewed literature to facilitate
informed decision-making regarding their use in clinical practice.
After critical analysis of the literature, only 22 products (37%)
had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita),
Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question
the need for so many different products, especially with limited
published clinical evidence for their efficacy, and conclude that
there is a considerable need for further prospective randomised
trials to facilitate informed decision-making with regard to the
use of current and future bone graft substitutes in clinical practice. Cite this article:
This study aimed to determine the long-term functional,
clinical and radiological outcomes in patients with Schatzker IV
to VI fractures of the tibial plateau treated with an Ilizarov frame.
Clinical, functional and radiological assessment was carried out
at a minimum of one year post-operatively. A cohort of 105 patients
(62 men, 43 women) with a mean age of 49 years (15 to 87) and a
mean follow-up of 7.8 years (1 to 19) were reviewed. There were
18 type IV, 10 type V and 77 type VI fractures. All fractures united
with a mean time to union of 20.1 weeks (10.6 to 42.3). No patient
developed a deep infection. The median range of movement (ROM) of
the knee was 110o and the median Iowa score was 85. Our study demonstrates good long-term functional outcome with
no deep infection; spanning the knee had no detrimental effect on
the ROM or functional outcome. High-energy fractures of the tibial plateau may be treated effectively
with a fine wire Ilizarov fixator. Cite this article:
We report a prospective single-blind controlled
study of the incidence of early wound infection after internal fixation for
trauma in 609 patients, of whom 132 were HIV-positive. Wounds were
assessed for healing using the ASEPSIS score. There was no significant
difference in the rate of infection between HIV-positive and HIV-negative
patients undergoing clean surgery (4.2% We conclude that clean implant surgery in HIV-positive patients
is safe, with no need for additional prophylaxis.