Advertisement for orthosearch.org.uk
Results 1 - 20 of 46
Results per page:
Bone & Joint Open
Vol. 3, Issue 10 | Pages 826 - 831
28 Oct 2022
Jukes C Dirckx M Bellringer S Chaundy W Phadnis J

Aims. The conventionally described mechanism of distal biceps tendon rupture (DBTR) is of a ‘considerable extension force suddenly applied to a resisting, actively flexed forearm’. This has been commonly paraphrased as an ‘eccentric contracture to a flexed elbow’. Both definitions have been frequently used in the literature with little objective analysis or citation. The aim of the present study was to use video footage of real time distal biceps ruptures to revisit and objectively define the mechanism of injury. Methods. An online search identified 61 videos reporting a DBTR. Videos were independently reviewed by three surgeons to assess forearm rotation, elbow flexion, shoulder position, and type of muscle contraction being exerted at the time of rupture. Prospective data on mechanism of injury and arm position was also collected concurrently for 22 consecutive patients diagnosed with an acute DBTR in order to corroborate the video analysis. Results. Four videos were excluded, leaving 57 for final analysis. Mechanisms of injury included deadlift, bicep curls, calisthenics, arm wrestling, heavy lifting, and boxing. In all, 98% of ruptures occurred with the arm in supination and 89% occurred at 0° to 10° of elbow flexion. Regarding muscle activity, 88% occurred during isometric contraction, 7% during eccentric contraction, and 5% during concentric contraction. Interobserver correlation scores were calculated as 0.66 to 0.89 using the free-marginal Fleiss Kappa tool. The prospectively collected patient data was consistent with the video analysis, with 82% of injuries occurring in supination and 95% in relative elbow extension. Conclusion. Contrary to the classically described injury mechanism, in this study the usual arm position during DBTR was forearm supination and elbow extension, and the muscle contraction was typically isometric. This was demonstrated for both video analysis and ‘real’ patients across a range of activities leading to rupture. Cite this article: Bone Jt Open 2022;3(10):826–831


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1165 - 1175
1 Oct 2024
Frost Teilmann J Petersen ET Thillemann TM Hemmingsen CK Olsen Kipp J Falstie-Jensen T Stilling M

Aims. The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA). Methods. Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom. Results. The greatest kinematic changes in the elbows were seen with the longest, + 4 mm, implant, which imposed a mean joint distraction of 2.8 mm in the radiohumeral joint and of 1.1 mm in the ulnohumeral joint, an increased mean varus angle of up to 2.4° for both the radius and the ulna, a mean shift of the radius of 2.0 mm in the ulnar direction, and a mean shift of the ulna of 1.0 mm posteriorly. Conclusion. The kinematics of the elbow deviated increasingly from those of the native joint with a 2 mm to a 4 mm lengthening of the radius. This confirms the importance of restoring the natural length of the radius when undertaking RHA. Cite this article: Bone Joint J 2024;106-B(10):1165–1175


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1301 - 1305
1 Nov 2024
Prajapati A Thakur RPS Gulia A Puri A

Aims. Reconstruction after osteoarticular resection of the proximal ulna for tumours is technically difficult and little has been written about the options that are available. We report a series of four patients who underwent radial neck to humeral trochlea transposition arthroplasty following proximal ulnar osteoarticular resection. Methods. Between July 2020 and July 2022, four patients with primary bone tumours of the ulna underwent radial neck to humeral trochlea transposition arthroplasty. Their mean age was 28 years (12 to 41). The functional outcome was assessed using the range of motion (ROM) of the elbow, rotation of the forearm and stability of the elbow, the Musculoskeletal Tumor Society score (MSTS), and the nine-item abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH-9) score. Results. All patients were available for follow-up at a mean of 33 months (25 to 43) and were disease-free. The mean flexion arc was 0° to 105°. Three patients had complications. One had neuropraxia of the ulnar nerve. The symptoms resolved after three months. In one patient, the screw used for fixation of the triceps tendon became exposed and was removed, six months postoperatively. One patient with wound dehiscence required a local flap for soft-tissue cover, four months postoperatively. At a mean follow-up of 33 months (25 to 43), the mean flexion arc was 0° to 105°. All patients had full supination (85°) but none had any pronation. The mean MSTS score was 23.5 (23 to 24) and mean QuickDASH-9 score was 26.13 (16.5 to 35.75). Three patients had varus-valgus instability on examination, although only one had a sense of instability while working. Conclusion. Radial neck to humeral trochlea transposition offers a satisfactory and cost-effective biological reconstructive option after osteoarticular resection of the proximal ulna, in the short term. It provides good elbow function and, being a biological reconstruction option using native bone, is likely to provide long-term stability and durability. Cite this article: Bone Joint J 2024;106-B(11):1301–1305


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1284 - 1291
1 Jul 2021
Carter TH Karunaratne BJ Oliver WM Murray IR White TO Reid JT Duckworth AD

Aims. Acute distal biceps tendon repair reduces fatigue-related pain and minimizes loss of supination of the forearm and strength of flexion of the elbow. We report the short- and long-term outcome following repair using fixation with a cortical button techqniue. Methods. Between October 2010 and July 2018, 102 patients with a mean age of 43 years (19 to 67), including 101 males, underwent distal biceps tendon repair less than six weeks after the injury, using cortical button fixation. The primary short-term outcome measure was the rate of complications. The primary long-term outcome measure was the abbreviated Disabilities of the Arm, Shoulder and Hand (QuickDASH) score. Secondary outcomes included the Oxford Elbow Score (OES), EuroQol five-dimension three-level score (EQ-5D-3L), satisfaction, and return to function. Results. Eight patients (7.8%) had a major complication and 34 (33.3%) had a minor complication. Major complications included re-rupture (n = 3; 2.9%), unrecovered nerve injury (n = 4; 3.9%), and surgery for heterotopic ossification (n = 1; 1.0%). Three patients (2.9%) overall required further surgery for a complication. Minor complications included neurapraxia (n = 27; 26.5%) and superficial infection (n = 7; 6.9%). A total of 33 nerve injuries occurred in 31 patients (30.4%). At a mean follow-up of five years (1 to 9.8) outcomes were available for 86 patients (84.3%). The median QuickDASH, OES, EQ-5D-3L, and satisfaction scores were 1.2 (IQR 0 to 5.1), 48 (IQR 46 to 48), 0.80 (IQR 0.72 to 1.0), and 100/100 (IQR 90 to 100), respectively. Most patients were able to return to work (81/83, 97.6%) and sport (51/62,82.3%). Unrecovered nerve injury was associated with an inferior outcome according to the QuickDASH (p = 0.005), OES (p = 0.004), EQ-5D-3L (p = 0.010), and satisfaction (p = 0.024). Multiple linear regression analysis identified an unrecovered nerve injury to be strongly associated with an inferior outcome according to the QuickDASH score (p < 0.001), along with infection (p < 0.001), although re-rupture (p = 0.440) and further surgery (p = 0.652) were not. Conclusion. Acute distal biceps tendon repair using cortical button fixation was found to result in excellent patient-reported outcomes and health-related quality of life. Although rare, unrecovered nerve injury adversely affects outcome. Cite this article: Bone Joint J 2021;103-B(7):1284–1291


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1620 - 1628
1 Dec 2020
Klug A Nagy A Gramlich Y Hoffmann R

Aims. To evaluate the outcomes of terrible triad injuries (TTIs) in mid-term follow-up and determine whether surgical treatment of the radial head influences clinical and radiological outcomes. Methods. Follow-up assessment of 88 patients with TTI (48 women, 40 men; mean age 57 years (18 to 82)) was performed after a mean of 4.5 years (2.0 to 9.4). The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder and Hand (DASH) score were evaluated. Radiographs of all patients were analyzed. Fracture types included 13 Mason type I, 16 type II, and 59 type III. Surgical treatment consisted of open reduction and internal fixation (ORIF) in all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) was performed if reconstruction was not possible. Results. At follow-up the mean MEPS was 87.1 (20 to 100); mean OES, 36.9 (6 to 48); and mean DASH score, 18.6 (0 to 90). Mean movement was 118° (30° to 150°) for extension to flexion and 162° (90° to 180°) for pronation to supination. The overall reoperation rate was 24%, with nine ORIF, ten RHA, and two patients without treatment to the radial head needing surgical revision. When treated with RHA, Mason type III fractures exhibited significantly inferior outcomes. Suboptimal results were also identified in patients with degenerative or heterotopic changes on their latest radiograph. In contrast, more favourable outcomes were detected in patients with successful radial head reconstruction after Mason type III fractures. Conclusion. Using a standardized protocol, sufficient elbow stability and good outcomes can be achieved in most TTIs. Although some bias in treatment allocation, with more severe injuries assigned to RHA, cannot be completely omitted, treatment of radial head fractures may have an independent effect on outcome, as patients subjected to RHA showed significantly inferior results compared to those subjected to reconstruction, in terms of elbow function, incidence of arthrosis, and postoperative complications. As RHA showed no apparent advantage in Mason type III injuries between the two treatment groups, we recommend reconstruction, providing stable fixation can be achieved. Cite this article: Bone Joint J 2020;102-B(12):1620–1628


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1362 - 1369
1 Nov 2019
Giannicola G Calella P Bigazzi P Mantovani A Spinello P Cinotti G

Aims. The aim of this study was to analyze the results of two radiocapitellar prostheses in a large case series followed prospectively, with medium-term follow-up. Patients and Methods. A total of 31 patients with a mean age of 54 years (27 to 73) were analyzed; nine had primary osteoarthritis (OA) and 17 had post-traumatic OA, three had capitellar osteonecrosis, and two had a fracture. Overall, 17 Lateral Resurfacing Elbow (LRE) and 14 Uni-Elbow Radio-Capitellum Implant (UNI-E) arthroplasties were performed. Pre- and postoperative assessment involved the Mayo Elbow Performance Score (MEPS), the Quick Disabilities of the Arm, Shoulder and Hand (Q-DASH) score, and the modified American Shoulder Elbow Surgeons (m-ASES) score. Results. The mean follow-up was 6.8 years (3.8 to 11.5). The mean MEPS, m-ASES, and Q-DASH scores improved significantly by 50 (p < 0.001), 55 (p < 0.001), and 54 points (p < 0.001), respectively, with no differences being detected between the implants. Preoperative pronation and supination were worse in patients in whom the UNI-E was used. Two patients with the UNI-E implant had asymptomatic evidence of gross loosening. Conclusion. Radiocapitellar arthroplasty yielded a significant improvement in elbow function at a mean follow-up of 6.8 years, with a high implant survival rate when the LRE was used in patients with primary or post-traumatic OA, without radial head deformity, and when the UNI-E was used in patients in whom radial head excision was indicated. Cite this article: Bone Joint J 2019;101-B:1362–1369


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1499 - 1505
1 Nov 2018
Mazhar FN Ebrahimi H Jafari D Mirzaei A

Aims. The crucial role of the radial head in the stability of the elbow in terrible triad injury is acknowledged. This retrospective study aims to compare the results of resection of a severely comminuted radial head with or without prosthetic arthroplasty as part of the reconstruction for this injury. Patients and Methods. The outcome of radial head resection was compared with prosthetic arthroplasty in 29 and 15 patients with terrible triad injuries, respectively. There were ten female patients (34.5%) in the resection group and six female patients (40%) in the prosthesis group. The mean age was 40.7 years (. sd. 13.6) in the resection group and 36 years (. sd. 9.4) in the prosthesis group. The mean follow-up of the patients was 24.4 months (. sd. 12) in the resection group and 45.8 months (. sd. 6.8) in the prosthesis group. Outcome measures included visual analogue scale (VAS) for pain, Mayo Elbow Performance Score (MEPS), Disabilities of Arm, Shoulder and Hand (DASH) Score, and range of movement. Postoperative radiological complications were also recorded. Results. The mean ranges of extension, flexion, supination, and pronation were not significantly different between the two study groups (p = 0.75, p = 0.65, p = 0.82, and p = 0.68, respectively). The mean VAS score, DASH score, and MEPS of the two groups were also not statistically significantly different (p = 0.93, p = 0.19, and p = 0.32, respectively). At the final visit, the elbow was stable in all patients. No patient was found to have developed an Essex–Lopresti injury. Osteoarthritis grade I and II was observed in five and three patients of the resection group, respectively, and four and one patients of the arthroplasty group, respectively. Conclusion. The outcome of patients undergoing treatment for terrible triad injuries is similar whether the patient’s radial head was excised or replaced. Cite this article: Bone Joint J 2018;100-B:1499–505


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1512 - 1519
1 Dec 2019
Klug A Konrad F Gramlich Y Hoffmann R Schmidt-Horlohé K

Aims. The aim of this study was to evaluate the outcome of Monteggia-like lesions at midterm follow-up and to determine whether the surgical treatment of the radial head influences the clinical and radiological results. Patients and Methods. A total of 78 patients with a Monteggia-like lesion, including 44 women and 34 men with a mean age of 54.7 years (19 to 80), were available for assessment after a mean 4.6 years (2 to 9.2). The outcome was assessed using the Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), Mayo Modified Wrist Score (MMWS), and The Disabilities of the Arm, Shoulder and Hand (DASH) score. Radiographs were analyzed for all patients. A total of 12 Mason type I, 16 type II, and 36 type III fractures were included. Surgical treatment consisted of screw fixation for all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) or excision was performed if reconstruction was not possible. Results. The mean MEPS was 88.9 (40 to 100), mean OES was 40.1 (25 to 48), mean MMWS was 88.1 (50 to 100), mean DASH score was 14.7 (0 to 60.2), and mean movement was 114° (. sd. 27) in extension/flexion and 155° (. sd. 37) in pronation/supination. Mason III fractures, particularly those with an associated coronoid fracture treated with RHA, had a significantly poorer outcome. Suboptimal results were also identified in patients who had degenerative changes or heterotopic ossification on their latest radiograph. In contrast, all patients with successful radial head reconstruction or excision had a good outcome. Conclusion. Good outcomes can be achieved in Monteggia-like lesions with Mason II and III fractures, when reconstruction is possible. Otherwise, RHA is a reliable option with satisfactory outcomes, especially in patients with ligamenteous instability. Whether the radial head should be excised remains debatable, although good results were achieved in patients with ligamentous stability and in those with complications after RHA. Cite this article: Bone Joint J 2019;101-B:1512–1519


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1158 - 1164
1 Oct 2024
Jakobi T Krieg I Gramlich Y Sauter M Schnetz M Hoffmann R Klug A

Aims

The aim of this study was to evaluate the outcome of complex radial head fractures at mid-term follow-up, and determine whether open reduction and internal fixation (ORIF) or radial head arthroplasty (RHA) should be recommended for surgical treatment.

Methods

Patients who underwent surgery for complex radial head fractures (Mason type III, ≥ three fragments) were divided into two groups (ORIF and RHA) and propensity score matching was used to individually match patients based on patient characteristics. Ultimately, 84 patients were included in this study. After a mean follow-up of 4.1 years (2.0 to 9.5), patients were invited for clinical and radiological assessment. The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire score were evaluated.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims

Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm.

Methods

An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1284 - 1292
1 Nov 2024
Moroder P Poltaretskyi S Raiss P Denard PJ Werner BC Erickson BJ Griffin JW Metcalfe N Siegert P

Aims

The objective of this study was to compare simulated range of motion (ROM) for reverse total shoulder arthroplasty (rTSA) with and without adjustment for scapulothoracic orientation in a global reference system. We hypothesized that values for simulated ROM in preoperative planning software with and without adjustment for scapulothoracic orientation would be significantly different.

Methods

A statistical shape model of the entire humerus and scapula was fitted into ten shoulder CT scans randomly selected from 162 patients who underwent rTSA. Six shoulder surgeons independently planned a rTSA in each model using prototype development software with the ability to adjust for scapulothoracic orientation, the starting position of the humerus, as well as kinematic planes in a global reference system simulating previously described posture types A, B, and C. ROM with and without posture adjustment was calculated and compared in all movement planes.


Bone & Joint Open
Vol. 4, Issue 1 | Pages 19 - 26
13 Jan 2023
Nishida K Nasu Y Hashizume K Okita S Nakahara R Saito T Ozaki T Inoue H

Aims

There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA).

Methods

We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain, range of motion, Mayo Elbow Performance Score (MEPS), radiological evaluation for radiolucent line and loosening, complications, and revision surgery with or without implant removal.


Bone & Joint Open
Vol. 3, Issue 9 | Pages 701 - 709
2 Sep 2022
Thompson H Brealey S Cook E Hadi S Khan SHM Rangan A

Aims

To achieve expert clinical consensus in the delivery of hydrodilatation for the treatment of primary frozen shoulder to inform clinical practice and the design of an intervention for evaluation.

Methods

We conducted a two-stage, electronic questionnaire-based, modified Delphi survey of shoulder experts in the UK NHS. Round one required positive, negative, or neutral ratings about hydrodilatation. In round two, each participant was reminded of their round one responses and the modal (or ‘group’) response from all participants. This allowed participants to modify their responses in round two. We proposed respectively mandating or encouraging elements of hydrodilatation with 100% and 90% positive consensus, and respectively disallowing or discouraging with 90% and 80% negative consensus. Other elements would be optional.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 964 - 969
1 Sep 2024
Wang YC Song JJ Li TT Yang D Lv ZB Wang ZY Zhang ZM Luo Y

Aims

To propose a new method for evaluating paediatric radial neck fractures and improve the accuracy of fracture angulation measurement, particularly in younger children, and thereby facilitate planning treatment in this population.

Methods

Clinical data of 117 children with radial neck fractures in our hospital from August 2014 to March 2023 were collected. A total of 50 children (26 males, 24 females, mean age 7.6 years (2 to 13)) met the inclusion criteria and were analyzed. Cases were excluded for the following reasons: Judet grade I and Judet grade IVb (> 85° angulation) classification; poor radiograph image quality; incomplete clinical information; sagittal plane angulation; severe displacement of the ulna fracture; and Monteggia fractures. For each patient, standard elbow anteroposterior (AP) view radiographs and corresponding CT images were acquired. On radiographs, Angle P (complementary to the angle between the long axis of the radial head and the line perpendicular to the physis), Angle S (complementary to the angle between the long axis of the radial head and the midline through the proximal radial shaft), and Angle U (between the long axis of the radial head and the straight line from the distal tip of the capitellum to the coronoid process) were identified as candidates approximating the true coronal plane angulation of radial neck fractures. On the coronal plane of the CT scan, the angulation of radial neck fractures (CTa) was measured and served as the reference standard for measurement. Inter- and intraobserver reliabilities were assessed by Kappa statistics and intraclass correlation coefficient (ICC).


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1327 - 1332
1 Nov 2024
Ameztoy Gallego J Diez Sanchez B Vaquero-Picado A Antuña S Barco R

Aims

In patients with a failed radial head arthroplasty (RHA), simple removal of the implant is an option. However, there is little information in the literature about the outcome of this procedure. The aim of this study was to review the mid-term clinical and radiological results, and the rate of complications and removal of the implant, in patients whose initial RHA was undertaken acutely for trauma involving the elbow.

Methods

A total of 11 patients in whom removal of a RHA without reimplantation was undertaken as a revision procedure were reviewed at a mean follow-up of 8.4 years (6 to 11). The range of motion (ROM) and stability of the elbow were recorded. Pain was assessed using a visual analogue scale (VAS). The functional outcome was assessed using the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score (OES), and the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH). Radiological examination included the assessment of heterotopic ossification (HO), implant loosening, capitellar erosion, overlengthening, and osteoarthritis. Complications and the rate of further surgery were also recorded.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1125 - 1132
1 Oct 2024
Luengo-Alonso G Valencia M Martinez-Catalan N Delgado C Calvo E

Aims

The prevalence of osteoarthritis (OA) associated with instability of the shoulder ranges between 4% and 60%. Articular cartilage is, however, routinely assessed in these patients using radiographs or scans (2D or 3D), with little opportunity to record early signs of cartilage damage. The aim of this study was to assess the prevalence and localization of chondral lesions and synovial damage in patients undergoing arthroscopic surgery for instablility of the shoulder, in order to classify them and to identify risk factors for the development of glenohumeral OA.

Methods

A total of 140 shoulders in 140 patients with a mean age of 28.5 years (15 to 55), who underwent arthroscopic treatment for recurrent glenohumeral instability, were included. The prevalence and distribution of chondral lesions and synovial damage were analyzed and graded into stages according to the division of the humeral head and glenoid into quadrants. The following factors that might affect the prevalence and severity of chondral damage were recorded: sex, dominance, age, age at the time of the first dislocation, number of dislocations, time between the first dislocation and surgery, preoperative sporting activity, Beighton score, type of instability, and joint laxity.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 905 - 911
1 Aug 2023
Giannicola G Amura A Sessa P Prigent S Cinotti G

Aims

The aim of this study was to analyze how proximal radial neck resorption (PRNR) starts and progresses radiologically in two types of press-fit radial head arthroplasties (RHAs), and to investigate its clinical relevance.

Methods

A total of 97 patients with RHA were analyzed: 56 received a bipolar RHA (Group 1) while 41 received an anatomical implant (Group 2). Radiographs were performed postoperatively and after three, six, nine, and 12 weeks, six, nine, 12, 18, and 24 months, and annually thereafter. PRNR was measured in all radiographs in the four radial neck quadrants. The Mayo Elbow Performance Score (MEPS), the abbreviated version of the Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH), and the patient-assessed American Shoulder and Elbow Surgeons score - Elbow (pASES-E) were used for the clinical assessment. Radiological signs of implant loosening were investigated.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1041 - 1048
19 Nov 2024
Delgado C Martínez-Rodríguez JM Candura D Valencia M Martínez-Catalán N Calvo E

Aims

The Bankart and Latarjet procedures are two of the most common surgical techniques to treat anterior shoulder instability with satisfactory clinical and functional outcomes. However, the outcomes in the adolescent population remain unclear, and there is no information regarding the arthroscopic Latarjet in this population. The purpose of this study was to evaluate the outcomes of the arthroscopic Bankart and arthroscopic Latarjet procedures in the management of anterior shoulder instability in adolescents.

Methods

We present a retrospective, matched-pair study of teenagers with anterior glenohumeral instability treated with an arthroscopic Bankart repair (ABR) or an arthroscopic Latarjet (AL) procedure with a minimum two-year follow-up. Preoperative demographic and clinical features, factors associated with dislocation, and complications were collected. Recurrence, defined as dislocation or subluxation, was established as the primary outcome. Clinical and functional outcomes were analyzed using objective (Rowe), and subjective (Western Ontario Shoulder Instability Index (WOSI) and Single Assessment Numeric Evaluation (SANE)) scores. Additionally, the rate of return to sport was assessed.


Bone & Joint Open
Vol. 2, Issue 7 | Pages 552 - 561
28 Jul 2021
Werthel J Boux de Casson F Burdin V Athwal GS Favard L Chaoui J Walch G

Aims

The aim of this study was to describe a quantitative 3D CT method to measure rotator cuff muscle volume, atrophy, and balance in healthy controls and in three pathological shoulder cohorts.

Methods

In all, 102 CT scans were included in the analysis: 46 healthy, 21 cuff tear arthropathy (CTA), 18 irreparable rotator cuff tear (IRCT), and 17 primary osteoarthritis (OA). The four rotator cuff muscles were manually segmented and their volume, including intramuscular fat, was calculated. The normalized volume (NV) of each muscle was calculated by dividing muscle volume to the patient’s scapular bone volume. Muscle volume and percentage of muscle atrophy were compared between muscles and between cohorts.


Bone & Joint Open
Vol. 2, Issue 1 | Pages 58 - 65
22 Jan 2021
Karssiens TJ Gill JR Sunil Kumar KH Sjolin SU

Aims

The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis.

Methods

From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration.