Advertisement for orthosearch.org.uk
Results 1 - 20 of 624
Results per page:
Bone & Joint Open
Vol. 3, Issue 11 | Pages 907 - 912
23 Nov 2022
Hurley RJ McCabe FJ Turley L Maguire D Lucey J Hurson CJ

Aims. The use of fluoroscopy in orthopaedic surgery creates risk of radiation exposure to surgeons. Appropriate personal protective equipment (PPE) can help mitigate this. The primary aim of this study was to assess if current radiation protection in orthopaedic trauma is safe. The secondary aims were to describe normative data of radiation exposure during common orthopaedic procedures, evaluate ways to improve any deficits in protection, and validate the use of electronic personal dosimeters (EPDs) in assessing radiation dose in orthopaedic surgery. Methods. Radiation exposure to surgeons during common orthopaedic trauma operations was prospectively assessed using EPDs and thermoluminescent dosimeters (TLDs). Normative data for each operation type were calculated and compared to recommended guidelines. Results. Current PPE appears to mitigate more than 90% of ionizing radiation in orthopaedic fluoroscopic procedures. There is a higher exposure to the inner thigh during seated procedures. EPDs provided results for individual procedures. Conclusion. PPE currently used by surgeons in orthopaedic trauma theatre adequately reduces radiation exposure to below recommended levels. Normative data per trauma case show specific anatomical areas of higher exposure, which may benefit from enhanced radiation protection. EPDs can be used to assess real-time radiation exposure in orthopaedic surgery. There may be a role in future medical wearables for orthopaedic surgeons. Cite this article: Bone Jt Open 2022;3(11):907–912


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 495 - 500
1 Apr 2020
Milligan DJ Cosgrove AP

Aims. To monitor the performance of services for developmental dysplasia of the hip (DDH) in Northern Ireland and identify potential improvements to enhance quality of service and plan for the future. Methods. This was a prospective observational study, involving all infants treated for DDH between 2011 and 2017. Children underwent clinical assessment and radiological investigation as per the regional surveillance policy. The regional radiology data was interrogated to quantify the use of ultrasound and ionizing radiation for this population. Results. Evidence-based changes were made to the Northern Ireland screening programme, including an increase in ultrasound scanning capacity and expansion of nurse-led screening clinics. The number of infant hip ultrasound scans increased from 4,788 in 2011, to approximately 7,000 in 2013 and subsequent years. The number of hip radiographs on infants of less than one year of age fell from 7,381 to 2,208 per year. There was a modest increase in the treatment rate from 10.9 to 14.3 per 1,000 live births but there was a significant reduction in the number of closed hip reductions. The incidence of infants diagnosed with DDH after one year of age was 0.30 per 1,000 live births over the entire period. Conclusion. Improving compliance with the regional infant hip screening protocols led to reduction in operative procedures and reduced the number of pelvic radiographs of infants. We conclude that performance monitoring of screening programmes for DDH is essential to provide a quality service. Cite this article: Bone Joint J 2020;102-B(4):495–500


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 739 - 745
1 Apr 2021
Mehta JS Hodgson K Yiping L Kho JSB Thimmaiah R Topiwala U Sawlani V Botchu R

Aims. To benchmark the radiation dose to patients during the course of treatment for a spinal deformity. Methods. Our radiation dose database identified 25,745 exposures of 6,017 children (under 18 years of age) and adults treated for a spinal deformity between 1 January 2008 and 31 December 2016. Patients were divided into surgical (974 patients) and non-surgical (5,043 patients) cohorts. We documented the number and doses of ionizing radiation imaging events (radiographs, CT scans, or intraoperative fluoroscopy) for each patient. All the doses for plain radiographs, CT scans, and intraoperative fluoroscopy were combined into a single effective dose by a medical physicist (milliSivert (mSv)). Results. There were more ionizing radiation-based imaging events and higher radiation dose exposures in the surgical group than in the non-surgical group (p < 0.001). The difference in effective dose for children between the surgical and non-surgical groups was statistically significant, the surgical group being significantly higher (p < 0.001). This led to a higher estimated risk of cancer induction for the surgical group (1:222 surgical vs 1:1,418 non-surgical). However, the dose difference for adults was not statistically different between the surgical and non-surgical groups. In all cases the effective dose received by all cohorts was significantly higher than that from exposure to natural background radiation. Conclusion. The treatment of spinal deformity is radiation-heavy. The dose exposure is several times higher when surgical treatment is undertaken. Clinicians should be aware of this and review their practices in order to reduce the radiation dose where possible. Cite this article: Bone Joint J 2021;103-B(4):1–7


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 241 - 245
1 Mar 2019
Leaver T Johnson B Lampard J Aarvold A Uglow M

Aims. The aim of this study was to quantify the risk of developing cancer from the exposure to radiation associated with surgery to correct limb deformities in children. Patients and Methods. A total of 35 children were studied. There were 19 girls and 16 boys. Their mean age was 11.9 years (2 to 18) at the time of surgery. Details of the radiological examinations were recorded during gradual correction using a Taylor Spatial Frame. The dose area product for each radiograph was obtained from the Computerised Radiology Information System database. The effective dose in millisieverts (mSv) was calculated using conversion coefficients for the anatomical area. The lifetime risk of developing cancer was calculated using government-approved Health Protection Agency reports, accounting for the age and gender of the child. Results. Correction was undertaken in five femurs, 18 tibiae, and 12 feet. The median duration of treatment was 45 months (11 to 118). The mean effective dose was 0.31 mSv (0.05 to 0.64) for the femur, 0.29 mSv (0.01 to 0.97) for the tibia, and 0.027 mSv (0.001 to 0.161) for the foot. The cumulative exposure gave ‘negligible’ risk in 26 children and ‘minimal’ risk in nine children, according to Public Health England categories. These results are below the mean annual background radiation in the United Kingdom. Conclusion. The lifetime attributable risk of developing cancer from repeated exposure to radiation was negligible or minimal in all children. This is the first study to quantify the exposure to radiation from serial radiographs in children with limb deformities who are treated surgically using circular external fixation, linking this to the risk of developing cancer. Cite this article: Bone Joint J 2019;101-B:241–245


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 23 - 27
1 Jan 2012
Uzoigwe CE Middleton RG

Radiological imaging is necessary in a wide variety of trauma and elective orthopaedic operations. The evolving orthopaedic workforce includes an increasing number of pregnant workers. Current legislation in the United Kingdom, Europe and United States allows them to choose their degree of participation, if any, with fluoroscopic procedures. For those who wish to engage in radiation-prone procedures, specific regulations apply to limit the radiation dose to the pregnant worker and unborn child. This paper considers those aspects of radiation protection, the potential effects of exposure to radiation in pregnancy and the dose of radiation from common orthopaedic procedures, which are important for safe clinical practice


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1060 - 1063
1 Aug 2007
Singh PJ Perera NS Dega R

We carried out a prospective study over a period of 12 months to measure the exposure to radiation of the hands of a dedicated foot and ankle surgeon. A thermoluminescent dosimeter ring (TLD) was used to measure the cumulative dose of radiation. Fluoroscopy was used in operations on the foot and ankle. The total screening time was 3028 s, with a mean time per procedure of 37.4 s (0.6 to 197). This correlated positively with the number of procedures performed (r = 0.92, p < 0.001), and with the dose of radiation in both the left (r = 0.85, p = 0.0005) and right TLDs (r = 0.59, p = 0.419). There was no significant difference in the dose of radiation between the two hands (t-test, p = 0.62). The total dose to the right TLD over the 12 months was 2.4 millisieverts. This is a simple and convenient method for evaluating the exposure of a single surgeon to radiation. The radiation detected was well below the annual dose limit set by the International Commission on Radiological Protection


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 944 - 950
1 Jul 2017
Fan G Fu Q Zhang J Zhang H Gu X Wang C Gu G Guan X Fan Y He S

Aims. Minimally invasive transforaminal lumbar interbody fusion (MITLIF) has been well validated in overweight and obese patients who are consequently subject to a higher radiation exposure. This prospective multicentre study aimed to investigate the efficacy of a novel lumbar localisation system for MITLIF in overweight patients. Patients and Methods. The initial study group consisted of 175 patients. After excluding 49 patients for various reasons, 126 patients were divided into two groups. Those in Group A were treated using the localisation system while those in Group B were treated by conventional means. The primary outcomes were the effective radiation dosage to the surgeon and the exposure time. Results. There were 62 patients in Group A and 64 in Group B. The mean effective dosage was 0.0217 mSv (standard deviation (. sd. ) 0.0079) in Group A and 0.0383 mSv (. sd. 0.0104) in Group B (p <  0.001). The mean fluoroscopy exposure time was 26.42 seconds (. sd. 5.91) in Group A and 40.67 seconds (. sd. 8.18) in Group B (p < 0.001). The operating time was 175.56 minutes (. sd. 32.23) and 206.08 minutes (. sd. 30.15) (p < 0.001), respectively. The mean pre-operative localisation time was 4.73 minutes (. sd. 0.84) in Group A and 7.03 minutes (. sd. 1.51) in Group B (p < 0.001). The mean screw placement time was 47.37 minutes (. sd. 10.43) in Group A and 67.86 minutes (. sd. 14.15) in Group B (p < 0.001). The pedicle screw violation rate was 0.35% (one out of 283) in Group A and 2.79% (eight out of 287) in Group B (p = 0.020). Conclusion. The study shows that the localisation system can effectively reduce radiation exposure, exposure time, operating time, pre-operative localisation time, and screw placement time in overweight patients undergoing MITLIF. Cite this article: Bone Joint J 2017;99-B:944–50


Bone & Joint Research
Vol. 5, Issue 7 | Pages 307 - 313
1 Jul 2016
Sandgren B Skorpil M Nowik P Olivecrona H Crafoord J Weidenhielm L Persson A

Objectives. Computed tomography (CT) plays an important role in evaluating wear and periacetabular osteolysis (PAO) in total hip replacements. One concern with CT is the high radiation exposure since standard pelvic CT provides approximately 3.5 millisieverts (mSv) of radiation exposure, whereas a planar radiographic examination with three projections totals approximately 0.5 mSv. The objective of this study was to evaluate the lowest acceptable radiation dose for dual-energy CT (DECT) images when measuring wear and periacetabular osteolysis in uncemented metal components. Materials and Methods. A porcine pelvis with bilateral uncemented hip prostheses and with known linear wear and acetabular bone defects was examined in a third-generation multidetector DECT scanner. The examinations were performed with four different radiation levels both with and without iterative reconstruction techniques. From the high and low peak kilo voltage acquisitions, polychrmoatic images were created together with virtual monochromatic images of energies 100 kiloelectron volts (keV) and 150 keV. Results. We could assess wear and PAO while substantially lowering the effective radiation dose to 0.7 mSv for a total pelvic view with an accuracy of around 0.5 mm for linear wear and 2 mm to 3 mm for PAO. Conclusion. CT for detection of prosthetic wear and PAO could be used with clinically acceptable accuracy at a radiation exposure level equal to plain radiographic exposures. Cite this article: B. Sandgren, M. Skorpil, P. Nowik, H. Olivecrona, J. Crafoord, L. Weidenhielm, A. Persson. Assessment of wear and periacetabular osteolysis using dual energy computed tomography on a pig cadaver to identify the lowest acceptable radiation dose. Bone Joint Res 2016;5:307–313. DOI: 10.1302/2046-3758.57.2000566


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 815 - 818
1 Aug 2001
Alonso JA Shaw DL Maxwell A McGill GP Hart GC

We measured the scattered radiation received by theatre staff, using high-sensitivity electronic personal dosimeters, during fixation of extracapsular fractures of the neck of the femur by dynamic hip screw. The dose received was correlated with that received by the patient, and the distance from the source of radiation. A scintillation detector and a water-filled model were used to define a map of the dose rate of scattered radiation in a standard operating theatre during surgery. Beyond two metres from the source of radiation, the scattered dose received was consistently low, while within the operating distance that received by staff was significant for both lateral and posteroanterior (PA) projections. The routine use of lead aprons outside the 2 m zone may be unnecessary. Within that zone it is recommended that lead aprons be worn and that thyroid shields are available for the surgeon and nursing assistants


The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 2 | Pages 268 - 280
1 May 1949
Ellis F

The problems of diagnosis and treatment of osteoclastoma are considered. The importance of full investigation, and the advantages of drill biopsy in confirming the diagnosis, are discussed. Treatment by radiation is believed to be better than treatment by surgical measures. Curettage and excision are unnecessary. Amputation for benign osteoclastoma is unjustifiable



The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 483 - 485
1 May 1989
Berg M Bergman B Hoborn J

We have evaluated the effect of shortwave ultraviolet radiation on bacterial levels in an operating theatre, both in experimental conditions and during 20 hip operations. When compared with the use of sham blue light, there was a significant reduction in the number of bacteria. The reduced level was comparable with that suggested for ultraclean air ventilation systems


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 370 - 374
1 Aug 1978
Grobbelaar C du Plessis T Marais F

The radiation crosslinking of high-density polyethylene prostheses was investigated over a wide range of doses in the presence and absence of gaseous crosslinking agents. It was found that in the bulk polymer the crosslinking pattern is completely different from the homogeneous crosslinking that occurs in polymer films. The presence of crosslinking agents causes highly crosslinked polymer to be formed on the surface while the bulk of the polymer is largely unaffected--which is explained in terms of diffusion phenomena. This surface crosslinking has a profound effect on the mechanical properties of the prostheses and restricts cold flow and deformation of the polymer without sacrificing the excellent abrasion-resistance properties of the polyethylene when subjected to high pressures. Based on this research a number of high-density polyethylene knee prostheses have been radiation-crosslinked and the results in vitro appear to be very promising


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 811 - 815
1 Sep 1991
Berg M Bergman B Hoborn J

Clean air in the operating room is important during joint replacement surgery. We compared monochromatic ultraviolet radiation of 254 nm with the use of a Charnley-Howorth air enclosure by bacterial air-sampling during 113 total hip arthroplasties. Air samples were taken continuously at the edge of the wound and every 15 minutes at a site 130 cm from the operating table. We also tested the effect of occlusive clothing for all personnel. Ultraviolet light was more efficient than the ultra-clean air enclosure, and occlusive clothing on its own or in combination also produced improvement. The implications of these findings are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 934 - 934
1 Nov 1992
Stoker D


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 332 - 334
1 May 1992
Hynes D Conere T Mee M Cashman W


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 517 - 519
1 Aug 1986
Pemberton J


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 4 - 5
1 Jan 1993
Stoker D


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 309 - 311
1 Mar 1990
De Santis G Williams J Dvir E O'Brien B Hurley J Goldberg I

A dose of 48 Gy of X-irradiation given over two to five weeks after grafting caused no significant delay in the rate of healing and only a small and statistically non-significant decrease in the torsional strength of the graft-bone junction of either vascularised or non-vascularised bone grafts of the tibiae of rabbits. Healing was faster and the union between the graft and adjacent bone developed torsional strength significantly more rapidly with vascularised than with non-vascularised grafts. These findings suggest that postoperative radiotherapy is unlikely to have a significantly deleterious effect on the healing of bone grafts used to repair defects produced by excision of malignant bone tumours.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 333 - 336
1 Apr 2004
Sinha S Evans SJ Arundell MK Burke FD