Advertisement for orthosearch.org.uk
Results 1 - 20 of 40
Results per page:

Aims. Olecranon fractures are usually caused by falling directly on to the olecranon or following a fall on to an outstretched arm. Displaced fractures of the olecranon with a stable ulnohumeral joint are commonly managed by open reduction and internal fixation. The current predominant method of management of simple displaced fractures with ulnohumeral stability (Mayo grade IIA) in the UK and internationally is a low-cost technique using tension band wiring. Suture or suture anchor techniques have been described with the aim of reducing the hardware related complications and reoperation. An all-suture technique has been developed to fix the fracture using strong synthetic sutures alone. The aim of this trial is to investigate the clinical and cost-effectiveness of tension suture repair versus traditional tension band wiring for the surgical fixation of Mayo grade IIA fractures of the olecranon. Methods. SOFFT is a multicentre, pragmatic, two-arm parallel-group, non-inferiority, randomized controlled trial. Participants will be assigned 1:1 to receive either tension suture fixation or tension band wiring. 280 adult participants will be recruited. The primary outcome will be the Disabilities of the Arm, Shoulder and Hand (DASH) score at four months post-randomization. Secondary outcome measures include DASH (at 12, 18, and 24 months), pain, Net Promotor Score (patient satisfaction), EuroQol five-dimension five-level score (EQ-5D-5L), radiological union, complications, elbow range of motion, and re-operations related to the injury or to remove metalwork. An economic evaluation will assess the cost-effectiveness of treatments. Discussion. There is currently no high-quality evidence comparing the clinical and cost effectiveness of the tension suture repair to the traditional tension band wiring currently offered for the internal fixation of displaced fractures of the olecranon. The Simple Olecranon Fracture Fixation Trial (SOFFT) is a randomized controlled trial with sufficient power and design rigour to provide this evidence for the subtype of Mayo grade IIA fractures. Cite this article: Bone Jt Open 2023;4(1):27–37


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 530 - 534
1 Apr 2014
Gallucci GL Piuzzi NS Slullitel PAI Boretto JG Alfie VA Donndorff A De Carli P

We retrospectively evaluated the clinical and radiological outcomes of a consecutive cohort of patients aged > 70 years with a displaced fracture of the olecranon, which was treated non-operatively with early mobilisation. We identified 28 such patients (27 women) with a mean age of 82 years (71 to 91). The elbow was initially immobilised in an above elbow cast in 90° of flexion of the elbow for a mean of five days. The cast was then replaced by a sling. Active mobilisation was encouraged as tolerated. No formal rehabilitation was undertaken. At a mean follow-up of 16 months (12 to 26), the mean ranges of flexion and extension were 140° and 15° respectively. On a visual analogue scale of 1 (no pain) to 10, the mean pain score was 1 (0 to 8). Of the original 28 patients 22 developed nonunion, but no patients required surgical treatment.

We conclude that non-operative functional treatment of displaced olecranon fractures in the elderly gives good results and a high rate of satisfaction.

Cite this article: Bone Joint J 2014;96-B:530–4.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 112 - 123
1 Feb 2023
Duckworth AD Carter TH Chen MJ Gardner MJ Watts AC

Despite being one of the most common injuries around the elbow, the optimal treatment of olecranon fractures is far from established and stimulates debate among both general orthopaedic trauma surgeons and upper limb specialists. It is almost universally accepted that stable non-displaced fractures can be safely treated nonoperatively with minimal specialist input. Internal fixation is recommended for the vast majority of displaced fractures, with a range of techniques and implants to choose from. However, there is concern regarding the complication rates, largely related to symptomatic metalwork resulting in high rates of implant removal. As the number of elderly patients sustaining these injuries increases, we are becoming more aware of the issues associated with fixation in osteoporotic bone and the often fragile soft-tissue envelope in this group. Given this, there is evidence to support an increasing role for nonoperative management in this high-risk demographic group, even in those presenting with displaced and/or multifragmentary fracture patterns. This review summarizes the available literature to date, focusing predominantly on the management techniques and available implants for stable fractures of the olecranon. It also offers some insights into the potential avenues for future research, in the hope of addressing some of the pertinent questions that remain unanswered. Cite this article: Bone Joint J 2023;105-B(2):112–123


Bone & Joint Open
Vol. 1, Issue 7 | Pages 376 - 382
10 Jul 2020
Gill JR Vermuyten L Schenk SA Ong JCY Schenk W

Aims. The aim of this study is to report the results of a case series of olecranon fractures and olecranon osteotomies treated with two bicortical screws. Methods. Data was collected retrospectively for all olecranon fractures and osteotomies fixed with two bicortical screws between January 2008 and December 2019 at our institution. The following outcome measures were assessed; re-operation, complications, radiological loss of reduction, and elbow range of flexion-extension. Results. Bicortical screw fixation was used to treat 17 olecranon fractures and ten osteotomies. The mean age of patients being treated for olecranon fracture and osteotomy were 48.6 years and 52.7 years respectively. Overall, 18% of olecranon fractures were classified as Mayo type I, 71% type II, and 12% type III. No cases of fracture or osteotomy required operative re-intervention. There were two cases of loss of fracture reduction which occurred in female patients ≥ 75 years of age with osteoporotic bone. In both cases, active extension and a functional range of movement was maintained and so the loss of reduction was managed non-operatively. For the fracture fixation cohort, at final follow-up mean elbow extension and flexion were -5. °. ± 5. °. and 136. °. ± 7. °. , with a mean arc of motion of 131. °. ± 11. °. . Conclusion. This series has shown that patients regain near full range of elbow flexion-extension and complication rates are low following bicortical screw fixation of olecranon fractures and osteotomy. Cite this article: Bone Joint Open 2020;1-7:376–382


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 627 - 635
1 Jul 1994
Papagelopoulos P Morrey B

We report the results in 24 consecutive patients treated from 1976 to 1991 for nonunion of olecranon fractures. Their mean age was 42 years, and the mean interval from fracture to treatment for nonunion was 19 months. Management was by rehabilitation and activity as tolerated for three, continued immobilisation for one, and operative treatment for 20. Operations included excision of the olecranon fragment (1), osteosynthesis (16), and joint replacement (3). Four patients also had distraction arthroplasty. At a mean follow-up of 18 months no patient had severe residual elbow pain but three had moderate and six had mild symptoms. The mean arc of motion was 98 degrees representing an average improvement of 11 degrees. Twelve patients had an excellent result, four good, six fair, and two a poor result. Union had been achieved in 15 of the 16 patients treated by osteosynthesis


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 964 - 972
1 Jul 2017
Duckworth AD Clement ND McEachan JE White TO Court-Brown CM McQueen MM

Aims

The aim of this prospective randomised controlled trial was to compare non-operative and operative management for acute isolated displaced fractures of the olecranon in patients aged ≥ 75 years.

Patients and Methods

Patients were randomised to either non-operative management or operative management with either tension-band wiring or fixation with a plate. They were reviewed at six weeks, three and six months and one year after the injury. The primary outcome measure was the Disabilities of the Arm, Shoulder and Hand (DASH) score at one year.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 367 - 372
1 May 1985
Fyfe I Mossad M Holdsworth B

This study was designed to compare the rigidity of the more commonly used techniques of internal fixation of fractures of the olecranon. Cadaveric elbow joints were mounted in a jig and controlled osteotomies performed to simulate transverse, oblique or comminuted fractures. Five techniques of internal fixation were tested by measuring movement at the fracture site after applying a bending moment to the ulna. At transverse osteotomies tension-band wiring with two tightening knots allowed least movement even at high loads. Intramedullary cancellous screw fixation gave erratic results; adding a tension band with a single know was little better. In oblique osteotomies, no statistically significant difference was shown between one-third tubular plate fixation and double-knot wiring. Comminuted osteotomies were held most rigidly by contoured one-third tubular plate fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 315 - 319
1 Feb 2010
Lalliss SJ Branstetter JG

Using an osteotomy of the olecranon as a model of a transverse fracture in 22 cadaver elbows we determined the ability of three different types of suture and stainless steel wire to maintain reduction when using a tension-band technique to stabilise the bone. Physiological cyclical loading simulating passive elbow movement (15 N) and using the arms to push up from a chair (450 N) were applied using an Instron materials testing machine whilst monitoring the osteotomy site with a video extensometer. Each osteotomy was repaired by one of four materials, namely, Stainless Steel Wire (7), No 2 Ethibond (3), No 5 Ethibond (5), or No 2 FiberWire (7).

There were no failures (movement of > 2 mm) with stainless steel wire or FiberWire and no significant difference in the movements measured across the site of the osteotomy (p = 0.99). The No. 2 Ethibond failed at 450 N and two of the five of No. 5 Ethibond sutures had a separation of > 2 mm at 450 N.

FiberWire as the tension band in this model held the reduction as effectively as stainless steel wire and may reduce the incidence of discomfort from the hardware. On the basis of our findings we suggest that a clinical trial should be undertaken


Bone & Joint 360
Vol. 13, Issue 4 | Pages 26 - 29
2 Aug 2024

The August 2024 Shoulder & Elbow Roundup. 360. looks at: Comparing augmented and nonaugmented locking-plate fixation for proximal humeral fractures in the elderly; Elevated five-year mortality following shoulder arthroplasty for fracture; Total intravenous anaesthesia with propofol reduces discharge times compared with inhaled general anaesthesia in shoulder arthroscopy: a randomized controlled trial; The influence of obesity on outcomes following arthroscopic rotator cuff repair; Humeral component version has no effect on outcomes following reverse total shoulder arthroplasty: a prospective, double-blinded, randomized controlled trial; What is a meaningful improvement after total shoulder arthroplasty by implant type, preoperative diagnosis, and sex?; The safety of corticosteroid injection prior to shoulder arthroplasty: a systematic review; Mortality and subsequent fractures of patients with olecranon fractures compared to other upper limb osteoporotic fractures


Bone & Joint 360
Vol. 13, Issue 1 | Pages 26 - 29
1 Feb 2024

The February 2024 Shoulder & Elbow Roundup. 360. looks at: Does indomethacin prevent heterotopic ossification following elbow fracture fixation?; Arthroscopic capsular shift in atraumatic shoulder joint instability; Ultrasound-guided lavage with corticosteroid injection versus sham; Combined surgical and exercise-based interventions following primary traumatic anterior shoulder dislocation: a systematic review and meta-analysis; Are vascularized fibula autografts a long-lasting reconstruction after intercalary resection of the humerus for primary bone tumours?; Anatomical versus reverse total shoulder arthroplasty with limited forward elevation; Tension band or plate fixation for simple displaced olecranon fractures?; Is long-term follow-up and monitoring in shoulder and elbow arthroplasty needed?


Bone & Joint 360
Vol. 3, Issue 3 | Pages 25 - 27
1 Jun 2014

The June 2014 Shoulder & Elbow Roundup. 360 . looks at: suprascapular nerve and rotator cuff pathology; anchors in Bankart repair: it’s not what you’ve got, but how you use it; not all shoulder PROMs are equal; reverse shoulder arthroplasty OK in trauma; not all in the mind: frozen shoulder personality debunked; open and arthroscopic repair equivalent in shoulder instability; natural history of olecranon fractures not so bleak?; and resurfacing of the shoulder: a Danish perspective


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1150 - 1157
1 Oct 2024
de Klerk HH Verweij LPE Doornberg JN Jaarsma RL Murase T Chen NC van den Bekerom MPJ

Aims

This study aimed to gather insights from elbow experts using the Delphi method to evaluate the influence of patient characteristics and fracture morphology on the choice between operative and nonoperative treatment for coronoid fractures.

Methods

A three-round electronic (e-)modified Delphi survey study was performed between March and December 2023. A total of 55 elbow surgeons from Asia, Australia, Europe, and North America participated, with 48 completing all questionnaires (87%). The panellists evaluated the factors identified as important in literature for treatment decision-making, using a Likert scale ranging from "strongly influences me to recommend nonoperative treatment" (1) to "strongly influences me to recommend operative treatment" (5). Factors achieving Likert scores ≤ 2.0 or ≥ 4.0 were deemed influential for treatment recommendation. Stable consensus is defined as an agreement of ≥ 80% in the second and third rounds.


Bone & Joint 360
Vol. 11, Issue 6 | Pages 3 - 4
1 Dec 2022
Ollivere B


Bone & Joint 360
Vol. 10, Issue 5 | Pages 29 - 32
1 Oct 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 965 - 968
1 Nov 1991
Hope P Williamson D Coates C Cole W

A prospective randomised clinical trial was undertaken to compare biodegradable polyglycolic acid pins with standard Kirschner wires used to fix displaced elbow fractures in children. Twenty-four children were enrolled in the trial; 14 had fractures of the lateral condyle of the humerus, eight of the medial epicondyle and two had olecranon fractures. Eleven fractures were fixed with Kirschner wires and 13 with polyglycolic acid pins. Fracture union with full function occurred in all cases within six months. Kirschner wires caused problems including infection in three cases, soft-tissue ossification in one and they required removal under general anaesthesia in nine cases. No such complications occurred with polyglycolic acid pins but one patient in this group developed avascular necrosis and premature fusion of the medial epicondyle


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 963 - 971
1 Aug 2022
Sun Z Liu W Liu H Li J Hu Y Tu B Wang W Fan C

Aims

Heterotopic ossification (HO) is a common complication after elbow trauma and can cause severe upper limb disability. Although multiple prognostic factors have been reported to be associated with the development of post-traumatic HO, no model has yet been able to combine these predictors more succinctly to convey prognostic information and medical measures to patients. Therefore, this study aimed to identify prognostic factors leading to the formation of HO after surgery for elbow trauma, and to establish and validate a nomogram to predict the probability of HO formation in such particular injuries.

Methods

This multicentre case-control study comprised 200 patients with post-traumatic elbow HO and 229 patients who had elbow trauma but without HO formation between July 2019 and December 2020. Features possibly associated with HO formation were obtained. The least absolute shrinkage and selection operator regression model was used to optimize feature selection. Multivariable logistic regression analysis was applied to build the new nomogram: the Shanghai post-Traumatic Elbow Heterotopic Ossification Prediction model (STEHOP). STEHOP was validated by concordance index (C-index) and calibration plot. Internal validation was conducted using bootstrapping validation.


Bone & Joint 360
Vol. 10, Issue 4 | Pages 37 - 40
1 Aug 2021


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 416 - 423
1 Apr 2022
Mourkus H Phillips NJ Rangan A Peach CA

Aims

The aim of this study was to investigate the outcome of periprosthetic fractures of the humerus and to assess the uniformity of the classifications used for these fractures (including those around elbow and/or shoulder arthroplasties) by performing a systematic review of the literature.

Methods

A systematic search was conducted using the National Institute for Health and Care Excellence Healthcare Databases Advance Search. For inclusion, studies had to report clinical outcomes following the management of periprosthetic fractures of the humerus. The protocol was registered on the PROSPERO database.


Bone & Joint 360
Vol. 9, Issue 5 | Pages 32 - 35
1 Oct 2020


Bone & Joint 360
Vol. 10, Issue 5 | Pages 12 - 13
1 Oct 2021