header advert
Results 1 - 50 of 425
Results per page:
Bone & Joint Open
Vol. 2, Issue 1 | Pages 48 - 57
19 Jan 2021
Asokan A Plastow R Kayani B Radhakrishnan GT Magan AA Haddad FS

Cementless knee arthroplasty has seen a recent resurgence in popularity due to conceptual advantages, including improved osseointegration providing biological fixation, increased surgical efficiency, and reduced systemic complications associated with cement impaction and wear from cement debris. Increasingly younger and higher demand patients are requiring knee arthroplasty, and as such, there is optimism cementless fixation may improve implant survivorship and functional outcomes. Compared to cemented implants, the National Joint Registry (NJR) currently reports higher revision rates in cementless total knee arthroplasty (TKA), but lower in unicompartmental knee arthroplasty (UKA). However, recent studies are beginning to show excellent outcomes with cementless implants, particularly with UKA which has shown superior performance to cemented varieties. Cementless TKA has yet to show long-term benefit, and currently performs equivalently to cemented in short- to medium-term cohort studies. However, with novel concepts including 3D-printed coatings, robotic-assisted surgery, radiostereometric analysis, and kinematic or functional knee alignment principles, it is hoped they may help improve the outcomes of cementless TKA in the long-term. In addition, though cementless implant costs remain higher due to novel implant coatings, it is speculated cost-effectiveness can be achieved through greater surgical efficiency and potential reduction in revision costs. There is paucity of level one data on long-term outcomes between fixation methods and the cost-effectiveness of modern cementless knee arthroplasty. This review explores recent literature on cementless knee arthroplasty, with regards to clinical outcomes, implant survivorship, complications, and cost-effectiveness; providing a concise update to assist clinicians on implant choice. Cite this article: Bone Jt Open 2021;2(1):48–57


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 613 - 619
2 May 2022
Ackerman IN Busija L Lorimer M de Steiger R Graves SE

Aims. This study aimed to describe the use of revision knee arthroplasty in Australia and examine changes in lifetime risk over a decade. Methods. De-identified individual-level data on all revision knee arthroplasties performed in Australia from 2007 to 2017 were obtained from the Australian Orthopaedic Association National Joint Replacement Registry. Population data and life tables were obtained from the Australian Bureau of Statistics. The lifetime risk of revision surgery was calculated for each year using a standardized formula. Separate calculations were undertaken for males and females. Results. In total, 43,188 revision knee arthroplasty procedures were performed in Australia during the study period, with a median age at surgery of 69 years (interquartile range (IQR) 62 to 76). In 2017, revision knee arthroplasty rates were highest for males aged 70 to 79 years (102.9 procedures per 100,000 population). Lifetime risk of revision knee arthroplasty for females increased slightly from 1.61% (95% confidence interval (CI) 1.53% to 1.69%) in 2007 to 2.22% (95% CI 2.13% to 2.31%) in 2017. A similar pattern was evident for males, with a lifetime risk of 1.43% (95% CI 1.36% to 1.51%) in 2007 and 2.02% (95% CI 1.93% to 2.11%) in 2017. A decline in procedures performed for loosening/lysis (from 41% in 2007 to 24% in 2017) and pain (from 14% to 9%) was evident, while infection became an increasingly common indication (from 19% in 2007 to 29% in 2017). Conclusion. Well-validated national registry data can help us understand the epidemiology of revision knee arthroplasty, including changing clinical indications. Despite a small increase over a decade, the lifetime risk of revision knee arthroplasty in Australia is low at one in 45 females and one in 50 males. These methods offer a population-level approach to quantifying revision burden that can be used for ongoing national surveillance and between-country comparisons. Cite this article: Bone Joint J 2022;104-B(5):613–619


Bone & Joint Research
Vol. 11, Issue 8 | Pages 575 - 584
17 Aug 2022
Stoddart JC Garner A Tuncer M Cobb JP van Arkel RJ

Aims. The aim of this study was to determine the risk of tibial eminence avulsion intraoperatively for bi-unicondylar knee arthroplasty (Bi-UKA), with consideration of the effect of implant positioning, overstuffing, and sex, compared to the risk for isolated medial unicondylar knee arthroplasty (UKA-M) and bicruciate-retaining total knee arthroplasty (BCR-TKA). Methods. Two experimentally validated finite element models of tibia were implanted with UKA-M, Bi-UKA, and BCR-TKA. Intraoperative loads were applied through the condyles, anterior cruciate ligament (ACL), medial collateral ligament (MCL), and lateral collateral ligament (LCL), and the risk of fracture (ROF) was evaluated in the spine as the ratio of the 95. th. percentile maximum principal elastic strains over the tensile yield strain of proximal tibial bone. Results. Peak tensile strains occurred on the anterior portion of the medial sagittal cut in all simulations. Lateral translation of the medial implant in Bi-UKA had the largest increase in ROF of any of the implant positions (43%). Overstuffing the joint by 2 mm had a much larger effect, resulting in a six-fold increase in ROF. Bi-UKA had ~10% increased ROF compared to UKA-M for both the male and female models, although the smaller, less dense female model had a 1.4 times greater ROF compared to the male model. Removal of anterior bone akin to BCR-TKA doubled ROF compared to Bi-UKA. Conclusion. Tibial eminence avulsion fracture has a similar risk associated with Bi-UKA to UKA-M. The risk is higher for smaller and less dense tibiae. To minimize risk, it is most important to avoid overstuffing the joint, followed by correctly positioning the medial implant, taking care not to narrow the bone island anteriorly. Cite this article: Bone Joint Res 2022;11(8):575–584


Bone & Joint Open
Vol. 4, Issue 3 | Pages 129 - 137
1 Mar 2023
Patel A Edwards TC Jones G Liddle AD Cobb J Garner A

Aims. The metabolic equivalent of task (MET) score examines patient performance in relation to energy expenditure before and after knee arthroplasty. This study assesses its use in a knee arthroplasty population in comparison with the widely used Oxford Knee Score (OKS) and EuroQol five-dimension index (EQ-5D), which are reported to be limited by ceiling effects. Methods. A total of 116 patients with OKS, EQ-5D, and MET scores before, and at least six months following, unilateral primary knee arthroplasty were identified from a database. Procedures were performed by a single surgeon between 2014 and 2019 consecutively. Scores were analyzed for normality, skewness, kurtosis, and the presence of ceiling/floor effects. Concurrent validity between the MET score, OKS, and EQ-5D was assessed using Spearman’s rank. Results. Postoperatively the OKS and EQ-5D demonstrated negative skews in distribution, with high kurtosis at six months and one year. The OKS demonstrated a ceiling effect at one year (15.7%) postoperatively. The EQ-5D demonstrated a ceiling effect at six months (30.2%) and one year (39.8%) postoperatively. The MET score did not demonstrate a skewed distribution or ceiling effect either at six months or one year postoperatively. Weak-moderate correlations were noted between the MET score and conventional scores at six months and one year postoperatively. Conclusion. In contrast to the OKS and EQ-5D, the MET score was normally distributed postoperatively with no ceiling effect. It is worth consideration as an arthroplasty outcome measure, particularly for patients with high expectations. Cite this article: Bone Jt Open 2023;4(3):129–137


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 47 - 55
1 Jan 2023
Clement ND Avery P Mason J Baker PN Deehan DJ

Aims. The aim of this study was to identify variables associated with time to revision, demographic details associated with revision indication, and type of prosthesis employed, and to describe the survival of hinge knee arthroplasty (HKA) when used for first-time knee revision surgery and factors that were associated with re-revision. Methods. Patient demographic details, BMI, American Society of Anesthesiologists (ASA) grade, indication for revision, surgical approach, surgeon grade, implant type (fixed and rotating), time of revision from primary implantation, and re-revision if undertaken were obtained from the National Joint Registry data for England, Wales, Northern Ireland, and the Isle of Man over an 18-year period (2003 to 2021). Results. There were 3,855 patient episodes analyzed with a median age of 73 years (interquartile range (IQR) 66 to 80), and the majority were female (n = 2,480, 64.3%). The median time to revision from primary knee arthroplasty was 1,219 days (IQR 579 to 2,422). Younger age (p < 0.001), decreasing ASA grade (p < 0.001), and indications for revision of sepsis (p < 0.001), unexplained pain (p < 0.001), non-polyethylene wear (p < 0.001), and malalignment (p < 0.001) were all associated with an earlier time to revision from primary implantation. The median follow-up was 4.56 years (range 0.00 to 17.52), during which there were 410 re-revisions. The overall unadjusted probability of re-revision for all revision HKAs at one, five, and ten years after surgery were 2.7% (95% confidence interval (CI) 2.2 to 3.3), 10.7% (95% CI 9.6 to 11.9), and 16.2% (95% CI 14.5 to 17.9), respectively. Male sex (p < 0.001), younger age (p < 0.001), revision for septic indications (p < 0.001) or implant fracture (p = 0.010), a fixed hinge (p < 0.001), or surgery performed by a non-consultant grade (p = 0.023) were independently associated with an increased risk of re-revision. Conclusion. There were several factors associated with time to first revision. The re-revision rate was 16.2% at ten years; however, the risk factors associated with an increased risk of re-revision could be used to counsel patients regarding their outcome. Cite this article: Bone Joint J 2023;105-B(1):47–55


Bone & Joint Research
Vol. 12, Issue 10 | Pages 624 - 635
4 Oct 2023
Harrison CJ Plessen CY Liegl G Rodrigues JN Sabah SA Beard DJ Fischer F

Aims. To map the Oxford Knee Score (OKS) and High Activity Arthroplasty Score (HAAS) items to a common scale, and to investigate the psychometric properties of this new scale for the measurement of knee health. Methods. Patient-reported outcome measure (PROM) data measuring knee health were obtained from the NHS PROMs dataset and Total or Partial Knee Arthroplasty Trial (TOPKAT). Assumptions for common scale modelling were tested. A graded response model (fitted to OKS item responses in the NHS PROMs dataset) was used as an anchor to calibrate paired HAAS items from the TOPKAT dataset. Information curves for the combined OKS-HAAS model were plotted. Bland-Altman analysis was used to compare common scale scores derived from OKS and HAAS items. A conversion table was developed to map between HAAS, OKS, and the common scale. Results. We included 3,329 response sets from 528 patients undergoing knee arthroplasty. These generally met the assumptions of unidimensionality, monotonicity, local independence, and measurement invariance. The HAAS items provided more information than OKS items at high levels of knee health. Combining both instruments resulted in higher test-level information than either instrument alone. The mean error between common scale scores derived from the OKS and HAAS was 0.29 logits. Conclusion. The common scale allowed more precise measurement of knee health than use of either the OKS or HAAS individually. These techniques for mapping PROM instruments may be useful for the standardization of outcome reporting, and pooling results across studies that use either PROM in individual-patient meta-analysis. Cite this article: Bone Joint Res 2023;12(10):624–635


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1176 - 1182
14 Sep 2020
Mathews JA Kalson NS Tarrant PM Toms AD

Aims. The James Lind Alliance aims to bring patients, carers, and clinicians together to identify uncertainties regarding care. A Priority Setting Partnership was established by the British Association for Surgery of the Knee in conjunction with the James Lind Alliance to identify research priorities related to the assessment, management, and rehabilitation of patients with persistent symptoms after knee arthroplasty. Methods. The project was conducted using the James Lind Alliance protocol. A steering group was convened including patients, surgeons, anaesthetists, nurses, physiotherapists, and researchers. Partner organizations were recruited. A survey was conducted on a national scale through which patients, carers, and healthcare professionals submitted key unanswered questions relating to problematic knee arthroplasties. These were analyzed, aggregated, and synthesized into summary questions and the relevant evidence was checked. After confirming that these were not answered in the current literature, 32 questions were taken forward to an interim prioritization survey. Data from this survey informed a shortlist taken to a final consensus meeting. Results. A total of 769 questions were received during the initial survey with national reach across the UK. These were refined into 32 unique questions by an independent information specialist. The interim prioritization survey was completed by 201 respondents and 25 questions were taken to a final consensus group meeting between patients, carers, and healthcare professionals. Consensus was reached for ranking the top ten questions for publication and dissemination. Conclusions. The top ten research priorities focused on pain, infection, stiffness, health service configuration, surgical and non-surgical management strategies, and outcome measures. This list will guide funders and help focus research efforts within the knee arthroplasty community. Cite this article: Bone Joint J 2020;102-B(9):1176–1182


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 627 - 634
1 Apr 2021
Sabah SA Alvand A Beard DJ Price AJ

Aims. To estimate the measurement properties for the Oxford Knee Score (OKS) in patients undergoing revision knee arthroplasty (responsiveness, minimal detectable change (MDC-90), minimal important change (MIC), minimal important difference (MID), internal consistency, construct validity, and interpretability). Methods. Secondary data analysis was performed for 10,727 patients undergoing revision knee arthroplasty between 2013 to 2019 using a UK national patient-reported outcome measure (PROM) dataset. Outcome data were collected before revision and at six months postoperatively, using the OKS and EuroQol five-dimension score (EQ-5D). Measurement properties were assessed according to COnsensus-based Standards for the selection of health status Measurement Instruments (COSMIN) guidelines. Results. A total of 9,219 patients had complete outcome data. Mean preoperative OKS was 16.7 points (SD 8.1), mean postoperative OKS 29.1 (SD 11.4), and mean change in OKS + 12.5 (SD 10.7). Median preoperative EQ-5D index was 0.260 (interquartile range (IQR) 0.055 to 0.691), median postoperative EQ-5D index 0.691 (IQR 0.516 to 0.796), and median change in EQ-5D index + 0.240 (IQR 0.000 to 0.567). Internal consistency was good with Cronbach’s α 0.88 (baseline) and 0.94 (post-revision). Construct validity found a high correlation of OKS total score with EQ-5D index (r = 0.76 (baseline), r = 0.83 (post-revision), p < 0.001). The OKS was responsive with standardized effect size (SES) 1.54 (95% confidence interval (CI) 1.51 to 1.57), compared to SES 0.83 (0.81 to 0.86) for the EQ-5D index. The MIC for the OKS was 7.5 points (95% CI 5.5 to 8.5) based on the optimal cut-off with specificity 0.72, sensitivity 0.60, and area under the curve 0.66. The MID for the OKS was 5.2 points. The MDC-90 was 3.9 points. The OKS did not demonstrate significant floor or ceiling effects. Conclusion. This study found that the OKS was a useful and valid instrument for assessment of outcome following revision knee arthroplasty. The OKS was responsive to change and demonstrated good measurement properties. Cite this article: Bone Joint J 2021;103-B(4):627–634


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1062 - 1066
1 Dec 2021
Krasin E Gold A Morgan S Warschawski Y

Aims. Hereditary haemochromatosis is a genetic disorder that is caused by several known mutations in the human homeostatic iron regulator protein (HFE) gene. Abnormal accumulation of iron causes a joint disease that resembles osteoarthritis (OA), but appears at a relatively younger age and is accompanied by cirrhosis, diabetes, and injury to other organs. Increased serum transferrin saturation and ferritin levels are known markers of haemochromatosis with high positive predictive values. Methods. We have retrospectively analyzed the iron studies of a cohort of 2,035 patients undergoing knee joint arthroplasty due to OA. Results. No patients had HFE gene C282Y, S65C, or H63D mutations testing. In total, 18 patients (2.96%) of the male cohort and 51 (3.58%) of the female cohort had pathologically increased ferritin levels that may be indicative of haemochromatosis. Seven patients (0.34%) had serum transferrin saturation above 45%. Conclusion. The awareness for the diagnosis of this disorder in Orthopaedics is low and needs improvement. Osteoarthritic patients undergoing knee arthroplasty should be routinely screened for haemochromatosis by iron studies and referred to genetic testing when needed. Level of evidence: Level III - Retrospective cohort study. Cite this article: Bone Jt Open 2021;2(12):1062–1066


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1183 - 1193
14 Sep 2020
Anis HK Strnad GJ Klika AK Zajichek A Spindler KP Barsoum WK Higuera CA Piuzzi NS

Aims. The purpose of this study was to develop a personalized outcome prediction tool, to be used with knee arthroplasty patients, that predicts outcomes (lengths of stay (LOS), 90 day readmission, and one-year patient-reported outcome measures (PROMs) on an individual basis and allows for dynamic modifiable risk factors. Methods. Data were prospectively collected on all patients who underwent total or unicompartmental knee arthroplasty at a between July 2015 and June 2018. Cohort 1 (n = 5,958) was utilized to develop models for LOS and 90 day readmission. Cohort 2 (n = 2,391, surgery date 2015 to 2017) was utilized to develop models for one-year improvements in Knee Injury and Osteoarthritis Outcome Score (KOOS) pain score, KOOS function score, and KOOS quality of life (QOL) score. Model accuracies within the imputed data set were assessed through cross-validation with root mean square errors (RMSEs) and mean absolute errors (MAEs) for the LOS and PROMs models, and the index of prediction accuracy (IPA), and area under the curve (AUC) for the readmission models. Model accuracies in new patient data sets were assessed with AUC. Results. Within the imputed datasets, the LOS (RMSE 1.161) and PROMs models (RMSE 15.775, 11.056, 21.680 for KOOS pain, function, and QOL, respectively) demonstrated good accuracy. For all models, the accuracy of predicting outcomes in a new set of patients were consistent with the cross-validation accuracy overall. Upon validation with a new patient dataset, the LOS and readmission models demonstrated high accuracy (71.5% and 65.0%, respectively). Similarly, the one-year PROMs improvement models demonstrated high accuracy in predicting ten-point improvements in KOOS pain (72.1%), function (72.9%), and QOL (70.8%) scores. Conclusion. The data-driven models developed in this study offer scalable predictive tools that can accurately estimate the likelihood of improved pain, function, and quality of life one year after knee arthroplasty as well as LOS and 90 day readmission. Cite this article: Bone Joint J 2020;102-B(9):1183–1193


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 586 - 592
1 May 2020
Wijn SRW Rovers MM van Tienen TG Hannink G

Aims. Recent studies have suggested that corticosteroid injections into the knee may harm the joint resulting in cartilage loss and possibly accelerating the progression of osteoarthritis (OA). The aim of this study was to assess whether patients with, or at risk of developing, symptomatic osteoarthritis of the knee who receive intra-articular corticosteroid injections have an increased risk of requiring arthroplasty. Methods. We used data from the Osteoarthritis Initiative (OAI), a multicentre observational cohort study that followed 4,796 patients with, or at risk of developing, osteoarthritis of the knee on an annual basis with follow-up available up to nine years. Increased risk for symptomatic OA was defined as frequent knee symptoms (pain, aching, or stiffness) without radiological evidence of OA and two or more risk factors, while OA was defined by the presence of both femoral osteophytes and frequent symptoms in one or both knees. Missing data were imputed with multiple imputations using chained equations. Time-dependent propensity score matching was performed to match patients at the time of receving their first injection with controls. The effect of corticosteroid injections on the rate of subsequent (total and partial) knee arthroplasty was estimated using Cox proportional-hazards survival analyses. Results. After removing patients lost to follow-up, 3,822 patients remained in the study. A total of 249 (31.3%) of the 796 patients who received corticosteroid injections, and 152 (5.0%) of the 3,026 who did not, had knee arthroplasty. In the matched cohort, Cox proportional-hazards regression resulted in a hazard ratio of 1.57 (95% confidence interval (CI) 1.37 to 1.81; p < 0.001) and each injection increased the absolute risk of arthroplasty by 9.4% at nine years’ follow-up compared with those who did not receive injections. Conclusion. Corticosteroid injections seem to be associated with an increased risk of knee arthroplasty in patients with, or at risk of developing, symptomatic OA of the knee. These findings suggest that a conservative approach regarding the treatment of these patients with corticosteroid injections should be recommended. Cite this article: Bone Joint J 2020;102-B(5):586–592


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1071 - 1080
1 Sep 2019
Abram SGF Judge A Beard DJ Carr AJ Price AJ

Aims. The aim of this study was to determine the long-term risk of undergoing knee arthroplasty in a cohort of patients with meniscal tears who had undergone arthroscopic partial meniscectomy (APM). Patients and Methods. A retrospective national cohort of patients with a history of isolated APM was identified over a 20-year period. Patients with prior surgery to the same knee were excluded. The primary outcome was knee arthroplasty. Hazard ratios (HRs) were adjusted by patient age, sex, year of APM, Charlson comorbidity index, regional deprivation, rurality, and ethnicity. Risk of arthroplasty in the index knee was compared with the patient’s contralateral knee (with vs without a history of APM). A total of 834 393 patients were included (mean age 50 years; 37% female). Results. Of those with at least 15 years of follow-up, 13.49% (16 256/120 493; 95% confidence interval (CI) 13.30 to 13.69) underwent subsequent arthroplasty within this time. In women, 22.07% (95% CI 21.64 to 22.51) underwent arthroplasty within 15 years compared with 9.91% of men (95% CI 9.71 to 10.12), corresponding to a risk ratio (RR) of 2.23 (95% CI 2.16 to 2.29). Relative to the general population, patients with a history of APM were over ten times more likely (RR 10.27; 95% CI 10.07 to 10.47) to undergo arthroplasty rising to almost 40 times more likely (RR 39.62; 95% CI 27.68 to 56.70) at a younger age (30 to 39 years). In patients with a history of APM in only one knee, the risk of arthroplasty in that knee was greatly elevated in comparison with the contralateral knee (no APM; HR 2.99; 95% CI 2.95 to 3.02). Conclusion. Patients developing a meniscal tear undergoing APM are at greater risk of knee arthroplasty than the general population. This risk is three-times greater in the patient’s affected knee than in the contralateral knee. Women in the cohort were at double the risk of progressing to knee arthroplasty compared with men. These important new reference data will inform shared decision making and enhance approaches to treatment, prevention, and clinical surveillance. Cite this article: Bone Joint J 2019;101-B:1071–1080


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 45 - 52
1 Jan 2022
Yapp LZ Clement ND Moran M Clarke JV Simpson AHRW Scott CEH

Aims. The aim of this study was to determine the long-term mortality rate, and to identify factors associated with this, following primary and revision knee arthroplasty (KA). Methods. Data from the Scottish Arthroplasty Project (1998 to 2019) were retrospectively analyzed. Patient mortality data were linked from the National Records of Scotland. Analyses were performed separately for the primary and revised KA cohorts. The standardized mortality ratio (SMR) with 95% confidence intervals (CIs) was calculated for the population at risk. Multivariable Cox proportional hazards were used to identify predictors and estimate relative mortality risks. Results. At a median 7.4 years (interquartile range (IQR) 4.0 to 11.6) follow-up, 27.8% of primary (n = 27,474/98,778) and 31.3% of revision (n = 2,611/8,343) KA patients had died. Both primary and revision cohorts had lower mortality rates than the general population (SMR 0.74 (95% CI 0.73 to 0.74); p < 0.001; SMR 0.83 (95% CI 0.80 to 0.86); p < 0.001, respectively), which persisted for 12 and eighteight years after surgery, respectively. Factors associated with increased risk of mortality after primary KA included male sex (hazard ratio (HR) 1.40 (95% CI 1.36 to 1.45)), increasing socioeconomic deprivation (HR 1.43 (95% CI 1.36 to 1.50)), inflammatory polyarthropathy (HR 1.79 (95% CI 1.68 to 1.90)), greater number of comorbidities (HR 1.59 (95% CI 1.51 to 1.68)), and periprosthetic joint infection (PJI) requiring revision (HR 1.92 (95% CI 1.57 to 2.36)) when adjusting for age. Similarly, male sex (HR 1.36 (95% CI 1.24 to 1.49)), increasing socioeconomic deprivation (HR 1.31 (95% CI 1.12 to 1.52)), inflammatory polyarthropathy (HR 1.24 (95% CI 1.12 to 1.37)), greater number of comorbidities (HR 1.64 (95% CI 1.33 to 2.01)), and revision for PJI (HR 1.35 (95% 1.18 to 1.55)) were independently associated with an increased risk of mortality following revision KA when adjusting for age. Conclusion. The SMR of patients undergoing primary and revision KA was lower than that of the general population and remained so for several years post-surgery. However, approximately one in four patients undergoing primary and one in three patients undergoing revision KA died within tenten years of surgery. Several patient and surgical factors, including PJI, were associated with the risk of mortality within ten years of primary and revision surgery. Cite this article: Bone Joint J 2022;104-B(1):45–52


Aims. Achievement of accurate microbiological diagnosis prior to revision is key to reducing the high rates of persistent infection after revision knee surgery. The effect of change in the microorganism between the first- and second-stage revision of total knee arthroplasty for periprosthetic joint infection (PJI) on the success of management is not clear. Methods. A two-centre retrospective cohort study was conducted to review the outcome of patients who have undergone two-stage revision for treatment of knee arthroplasty PJI, focusing specifically on isolated micro-organisms at both the first- and second-stage procedure. Patient demographics, medical, and orthopaedic history data, including postoperative outcomes and subsequent treatment, were obtained from the electronic records and medical notes. Results. The study cohort consisted of 84 patients, of whom 59.5% (n = 50) had successful eradication of their infection at a mean follow-up of 4.7 years. For the 34 patients who had recurrence of infection, 58.8% (n = 20) had a change in isolated organism, compared to 18% (n = 9) in the infection eradication group (p < 0.001). When adjusting for confound, there was no association when the growth on the second stage was the same as the first (odd ratio (OR) 2.50, 95% confidence interval (CI) 0.49 to 12.50; p = 0.269); however, when a different organism was identified at the second stage, this was independently associated with failure of treatment (OR 8.40, 95% CI 2.91 to 24.39; p < 0.001). There were no other significant differences between the two cohorts with regard to patient demographics or type of organisms isolated. Conclusion. Change in the identified microorganism between first- and second-stage revision for PJI was associated with failure of management. Identification of this change in the microorganism prior to commencement of the second stage may help target antibiotic management and could improve the success of surgery in these patients. Cite this article: Bone Jt Open 2023;4(9):720–727


Aims. The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) at one year post-surgery. Methods. A total of 76 patients (34 bi-UKA and 42 TKA patients) were analyzed in a prospective, single-centre, randomized controlled trial. Flat ground shod gait analysis was performed preoperatively and one year postoperatively. Knee flexion moment was calculated from motion capture markers and force plates. The same setup determined proprioception outcomes during a joint position sense test and one-leg standing. Surgery allocation, surgeon, and secondary outcomes were analyzed for prediction of the primary outcome from a binary regression model. Results. Both interventions were shown to be effective treatment options, with no significant differences shown between interventions for the primary outcome of this study (18/35 (51.4%) biphasic TKA patients vs 20/31 (64.5%) biphasic bi-UKA patients; p = 0.558). All outcomes were compared to an age-matched, healthy cohort that outperformed both groups, indicating residual deficits exists following surgery. Logistic regression analysis of primary outcome with secondary outcomes indicated that the most significant predictor of postoperative biphasic knee moments was preoperative knee moment profile and trochlear degradation (Outerbridge) (R. 2. = 0.381; p = 0.002, p = 0.046). A separate regression of alignment against primary outcome indicated significant bi-UKA femoral and tibial axial alignment (R. 2. = 0.352; p = 0.029), and TKA femoral sagittal alignment (R. 2. = 0.252; p = 0.016). The bi-UKA group showed a significant increased ability in the proprioceptive joint position test, but no difference was found in more dynamic testing of proprioception. Conclusion. Robotic arm-assisted bi-UKA demonstrated equivalence to TKA in achieving a biphasic gait pattern after surgery for osteoarthritis of the knee. Both treatments are successful at improving gait, but both leave the patients with a functional limitation that is not present in healthy age-matched controls. Cite this article: Bone Joint J 2022;103-B(4):433–443


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1578 - 1585
1 Oct 2021
Abram SGF Sabah SA Alvand A Price AJ

Aims. To compare rates of serious adverse events in patients undergoing revision knee arthroplasty with consideration of the indication for revision (urgent versus elective indications), and compare these with primary arthroplasty and re-revision arthroplasty. Methods. Patients undergoing primary knee arthroplasty were identified in the national Hospital Episode Statistics (HES) between 1 April 1997 to 31 March 2017. Subsequent revision and re-revision arthroplasty procedures in the same patients and same knee were identified. The primary outcome was 90-day mortality and a logistic regression model was used to investigate factors associated with 90-day mortality and secondary adverse outcomes, including infection (undergoing surgery), pulmonary embolism, myocardial infarction, and stroke. Urgent indications for revision arthroplasty were defined as infection or fracture, and all other indications (e.g. loosening, instability, wear) were included in the elective indications cohort. Results. A total of 939,021 primary knee arthroplasty procedures were included (939,021 patients), of which 40,854 underwent subsequent revision arthroplasty, and 9,100 underwent re-revision arthroplasty. Revision surgery for elective indications was associated with a 90-day rate of mortality of 0.44% (135/30,826; 95% confidence interval (CI) 0.37 to 0.52) which was comparable to primary knee arthroplasty (0.46%; 4,292/939,021; 95% CI 0.44 to 0.47). Revision arthroplasty for infection was associated with a much higher mortality of 2.04% (184/9037; 95% CI 1.75 to 2.35; odds ratio (OR) 3.54; 95% CI 2.81 to 4.46), as was revision for periprosthetic fracture at 5.25% (52/991; 95% CI 3.94 to 6.82; OR 6.23; 95% CI 4.39 to 8.85). Higher rates of pulmonary embolism, myocardial infarction, and stroke were also observed in the infection and fracture cohort. Conclusion. Patients undergoing revision arthroplasty for urgent indications (infection or fracture) are at higher risk of mortality and serious adverse events in comparison to primary knee arthroplasty and revision arthroplasty for elective indications. These findings will be important for patient consent and shared decision-making and should inform service design for this patient cohort. Cite this article: Bone Joint J 2021;103-B(10):1578–1585


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1561 - 1570
1 Oct 2021
Blyth MJG Banger MS Doonan J Jones BG MacLean AD Rowe PJ

Aims. The aim of this study was to compare the clinical outcomes of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) during the first six weeks and at one year postoperatively. Methods. A per protocol analysis of 76 patients, 43 of whom underwent TKA and 34 of whom underwent bi-UKA, was performed from a prospective, single-centre, randomized controlled trial. Diaries kept by the patients recorded pain, function, and the use of analgesics daily throughout the first week and weekly between the second and sixth weeks. Patient-reported outcome measures (PROMs) were compared preoperatively, and at three months and one year postoperatively. Data were also compared longitudinally and a subgroup analysis was conducted, stratified by preoperative PROM status. Results. Both operations were shown to offer comparable outcomes, with no significant differences between the groups across all timepoints and outcome measures. Both groups also had similarly low rates of complications. Subgroup analysis for preoperative psychological state, activity levels, and BMI showed no difference in outcomes between the two groups. Conclusion. Robotic arm-assisted, cruciate-sparing bi-UKA offered similar early clinical outcomes and rates of complications to a mechanically aligned TKA, both in the immediate postoperative period and up to one year following surgery. Further work is required to identify which patients with osteoarthritis of the knee will derive benefit from a cruciate-sparing bi-UKA. Cite this article: Bone Joint J 2021;103-B(10):1561–1570


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1016 - 1021
1 Aug 2006
Delport HP Banks SA De Schepper J Bellemans J

Mobile-bearing posterior-stabilised knee replacements have been developed as an alternative to the standard fixed- and mobile-bearing designs. However, little is known about the in vivo kinematics of this new group of implants. We investigated 31 patients who had undergone a total knee replacement with a similar prosthetic design but with three different options: fixed-bearing posterior cruciate ligament-retaining, fixed-bearing posterior-stabilised and mobile-bearing posterior-stabilised. To do this we used a three-dimensional to two-dimensional model registration technique. Both the fixed- and mobile-bearing posterior-stabilised configurations used the same femoral component. We found that fixed-bearing posterior stabilised and mobile-bearing posterior-stabilised knee replacements demonstrated similar kinematic patterns, with consistent femoral roll-back during flexion. Mobile-bearing posterior-stabilised knee replacements demonstrated greater and more natural internal rotation of the tibia during flexion than fixed-bearing posterior-stabilised designs. Such rotation occurred at the interface between the insert and tibial tray for mobile-bearing posterior-stabilised designs. However, for fixed-bearing posterior-stabilised designs, rotation occurred at the proximal surface of the bearing. Posterior cruciate ligament-retaining knee replacements demonstrated paradoxical sliding forward of the femur. We conclude that mobile-bearing posterior-stabilised knee replacements reproduce internal rotation of the tibia more closely during flexion than fixed-bearing posterior-stabilised designs. Furthermore, mobile-bearing posterior-stabilised knee replacements demonstrate a unidirectional movement which occurs at the upper and lower sides of the mobile insert. The femur moves in an anteroposterior direction on the upper surface of the insert, whereas the movement at the lower surface is pure rotation. Such unidirectional movement may lead to less wear when compared with the multidirectional movement seen in fixed-bearing posterior-stabilised knee replacements, and should be associated with more evenly applied cam-post stresses


Bone & Joint Open
Vol. 4, Issue 11 | Pages 889 - 898
23 Nov 2023
Clement ND Fraser E Gilmour A Doonan J MacLean A Jones BG Blyth MJG

Aims

To perform an incremental cost-utility analysis and assess the impact of differential costs and case volume on the cost-effectiveness of robotic arm-assisted unicompartmental knee arthroplasty (rUKA) compared to manual (mUKA).

Methods

This was a five-year follow-up study of patients who were randomized to rUKA (n = 64) or mUKA (n = 65). Patients completed the EuroQol five-dimension questionnaire (EQ-5D) preoperatively, and at three months and one, two, and five years postoperatively, which was used to calculate quality-adjusted life years (QALYs) gained. Costs for the primary and additional surgery and healthcare costs were calculated.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1645 - 1649
1 Dec 2013
Bernhoff K Rudström H Gedeborg R Björck M

Popliteal artery injury (PAI) is a feared complication during knee replacement. Our aim was to investigate those injuries that occurred in association with knee replacement in terms of the type of injury, treatment and outcomes. From our national vascular registry (Swedvasc) and the Swedish Patient Insurance databases a total of 32 cases were identified. Prospective data from the registries was supplemented with case-records, including long-term follow-up. We estimated the incidence during 1998 to 2010 to be 0.017%. In our series of 32 patients with PAI occurring between 1987 and 2011, 25 (78%) were due to penetrating trauma and seven were caused by blunt trauma. The patients presented in three ways: bleeding (14), ischaemia (7) and false aneurysm formation (11), and five occurred during revision surgery. A total of 12 injuries were detected intra-operatively, eight within 24 hours (3 to 24) and 12 at more than 24 hours post-operatively (2 to 90 days). Treatment comprised open surgery in 28 patients. Patency of the vascular repair at 30 days was 97% (31 of 32, one amputation). At the time of follow-up (median 546 days, mean 677 days (24 to 1251)), 25 patients had residual symptoms. Of seven patients with a complete recovery, six had had an early diagnosis of the PAI during the procedure, and were treated by a vascular surgeon in the same hospital. PAI is a rare adverse event during knee replacement surgery. The outcome following such events is often adversely affected by diagnostic and therapeutic delay. Bleeding and false aneurysm were the most common clinical presentations. Cite this article: Bone Joint J 2013;95-B:1645–9


Bone & Joint Open
Vol. 3, Issue 6 | Pages 495 - 501
14 Jun 2022
Keohane D Sheridan GA Masterson E

Aims

Total knee arthroplasty (TKA) is a common and safe orthopaedic procedure. Zimmer Biomet's NexGen is the second most popular brand of implant used in the UK. The primary cause of revision after the first year is aseptic loosening. We present our experience of using this implant, with significant concerns around its performance with regards early aseptic loosening of the tibial component.

Methods

A retrospective, single-surgeon review was carried out of all of the NexGen Legacy Posterior Stabilized (LPS) TKAs performed in this institute. The specific model used for the index procedures was the NexGen Complete Knee System (Legacy Knee-Posterior Stabilized LPS-Flex Articular Surface, LPS-Flex Femoral Component Option, and Stemmed Nonaugmentable Tibial Component Option).


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1511 - 1518
1 Nov 2020
Banger MS Johnston WD Razii N Doonan J Rowe PJ Jones BG MacLean AD Blyth MJG

Aims. The aim of this study was to compare robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) in order to determine the changes in the anatomy of the knee and alignment of the lower limb following surgery. Methods. An analysis of 38 patients who underwent TKA and 32 who underwent bi-UKA was performed as a secondary study from a prospective, single-centre, randomized controlled trial. CT imaging was used to measure coronal, sagittal, and axial alignment of the knee preoperatively and at three months postoperatively to determine changes in anatomy that had occurred as a result of the surgery. The hip-knee-ankle angle (HKAA) was also measured to identify any differences between the two groups. Results. The pre- to postoperative changes in joint anatomy were significantly less in patients undergoing bi-UKA in all three planes in both the femur and tibia, except for femoral sagittal component orientation in which there was no difference. Overall, for the six parameters of alignment (three femoral and three tibial), 47% of bi-UKAs and 24% TKAs had a change of < 2° (p = 0.045). The change in HKAA towards neutral in varus and valgus knees was significantly less in patients undergoing bi-UKA compared with those undergoing TKA (p < 0.001). Alignment was neutral in those undergoing TKA (mean 179.5° (SD 3.2°)) while those undergoing bi-UKA had mild residual varus or valgus alignment (mean 177.8° (SD 3.4°)) (p < 0.001). Conclusion. Robotic-assisted, cruciate-sparing bi-UKA maintains the natural anatomy of the knee in the coronal, sagittal, and axial planes better, and may therefore preserve normal joint kinematics, compared with a mechanically aligned TKA. This includes preservation of coronal joint line obliquity. HKAA alignment was corrected towards neutral significantly less in patients undergoing bi-UKA, which may represent restoration of the pre-disease constitutional alignment (p < 0.001). Cite this article: Bone Joint J 2020;102-B(11):1511–1518


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 227 - 232
1 Feb 2019
Walker T Rutkowski L Innmann M Panzram B Herre J Gotterbarm T Aldinger PR Merle C

Aims. The treatment of patients with allergies to metal in total joint arthroplasty is an ongoing debate. Possibilities include the use of hypoallergenic prostheses, as well as the use of standard cobalt-chromium (CoCr) alloy. This non-designer study was performed to evaluate the clinical outcome and survival rates of unicondylar knee arthroplasty (UKA) using a standard CoCr alloy in patients reporting signs of a hypersensitivity to metal. Patients and Methods. A consecutive series of patients suitable for UKA were screened for symptoms of metal hypersensitivity by use of a questionnaire. A total of 82 patients out of 1737 patients suitable for medial UKA reporting cutaneous metal hypersensitivity to cobalt, chromium, or nickel were included into this study and prospectively evaluated to determine the functional outcome, possible signs of hypersensitivity, and short-term survivorship at a minimum follow-up of 1.5 years. Results. At a mean follow-up of three years (1.5 to 5.7), no local or systemic symptoms of hypersensitivity to metal were observed. One patient underwent revision surgery to a bicondylar prosthesis due to a tibial periprosthetic fracture resulting in a survival rate of 98.8% (95% confidence interval (CI) 91.7 to 99.8; number at risk, 28) at three years with the endpoint of revision for any reason and a survival rate of 97.6% (95% CI 90.6 to 99.3; number at risk, 29) for the endpoint of all reoperations. Clinical outcome was good to excellent with a mean Oxford Knee Score of 42.5 (. sd. 2.5; 37 to 48). Conclusion. This study is the first demonstrating clinical results and survival analysis of UKA using a CoCr alloy in patients with a history of metal hypersensitivity. Functional outcome and survivorship are on a high-level equivalent to those reported for UKA in patients without a history of metal hypersensitivity. No serious local or systemic symptoms of metal hypersensitivity could be detected, and no revision surgery was performed due to an adverse reaction to metal ions


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1323 - 1328
1 Dec 2022
Cochrane NH Kim B Seyler TM Bolognesi MP Wellman SS Ryan SP

Aims

In the last decade, perioperative advancements have expanded the use of outpatient primary total knee arthroplasty (TKA). Despite this, there remains limited data on expedited discharge after revision TKA. This study compared 30-day readmissions and reoperations in patients undergoing revision TKA with a hospital stay greater or less than 24 hours. The authors hypothesized that expedited discharge in select patients would not be associated with increased 30-day readmissions and reoperations.

Methods

Aseptic revision TKAs in the National Surgical Quality Improvement Program database were reviewed from 2013 to 2020. TKAs were stratified by length of hospital stay (greater or less than 24 hours). Patient demographic details, medical comorbidities, American Society of Anesthesiologists (ASA) grade, operating time, components revised, 30-day readmissions, and reoperations were compared. Multivariate analysis evaluated predictors of discharge prior to 24 hours, 30-day readmission, and reoperation.


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 42 - 49
1 Jan 2018
Walker T Zahn N Bruckner T Streit MR Mohr G Aldinger PR Clarius M Gotterbarm T

Aims. The aim of this independent multicentre study was to assess the mid-term results of mobile bearing unicondylar knee arthroplasty (UKA) for isolated lateral osteoarthritis of the knee joint. Patients and Methods. We retrospectively evaluated 363 consecutive, lateral UKAs (346 patients) performed using the Oxford domed lateral prosthesis undertaken in three high-volume knee arthroplasty centres between 2006 and 2014. Mean age of the patients at surgery was 65 years (36 to 88) with a mean final follow-up of 37 months (12 to 93). Results. A total of 36 (10.5%) patients underwent revision surgery, giving a survival rate of 90.1% at three years (95% confidence intervals (CI) 86.1 to 93.1; number at risk: 155) and 85.0% at five years (95% CI 77.9 to 89.9; number at risk: 43). Dislocation of the mobile bearing occurred in 18 patients (5.6%) at three years (95% CI 1.0 to 16.4; number at risk: 154) and in 20 patients (8.5%) at five years (95% CI 1.0 to 27.0; number at risk: 42). There were no significant differences in the dislocation rate between the participating centres or the surgeons. We were not able to identify an effect of each surgeon’s learning curve on the dislocation rate of the mobile bearing. The clinical outcome in patients without revision surgery at final follow-up was good to excellent, with a mean Oxford knee score of 40.3 (95% CI 39.4 to 41.2), a mean Tegner activity score of 3.2 (95% CI 3.1 to 3.3) and a mean University of California, Los Angeles score of 5.7 (95% CI 5.5 to 5.9). Conclusion. Our data, which consists of a high number of patients treated with mobile bearing UKA in the lateral compartment, indicates a high revision rate of 15% at five years with dislocation of the mobile bearing being the main reason for implant failure. Despite the good functional and clinical results and the high patient satisfaction in our study group, we therefore discontinued using mobile-bearing lateral UKA in favour of a fixed-bearing component. Cite this article: Bone Joint J 2018;100-B:42–9


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 339 -
1 Apr 2001
Dunbar MJ Robertsson O Ryd L Lidgren L

The Swedish Knee Arthroplasty Registry (SKAR) has recorded knee arthroplasties prospectively in Sweden since 1975. The only outcome measure available to date has been revision status. While questionnaires on health outcome may function as more comprehensive endpoints, it is unclear which are the most appropriate. We tested various outcome questionnaires in order to determine which is the best for patients who have had knee arthroplasty as applied in a cross-sectional, discriminative, postal survey. Four general health questionnaires (NHP, SF-12, SF-36 and SIP) and three disease/site-specific questionnaires (Lequesne, Oxford-12, and WOMAC) were tested on 3600 patients randomly selected from the SKAR. Differences were found between questionnaires in response rate, time required for completion, the need for assistance, the efficiency of completion, the validity of the content and the reliability. The mean overall ranks for each questionnaire were generated. The SF-12 ranked the best for the general health, and the Oxford-12 for the disease/site-specific questionnaires. These two questionnaires could therefore be recommended as the most appropriate for use with a large knee arthroplasty database in a cross-sectional population


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 914 - 918
1 Jul 2012
Jameson SS Baker PN Charman SC Deehan DJ Reed MR Gregg PJ Van der Meulen JH

We compared thromboembolic events, major haemorrhage and death after knee replacement in patients receiving either aspirin or low-molecular-weight heparin (LMWH). Data from the National Joint Registry for England and Wales were linked to an administrative database of hospital admissions in the English National Health Service. A total of 156 798 patients between April 2003 and September 2008 were included and followed for 90 days. Multivariable risk modelling was used to estimate odds ratios adjusted for baseline risk factors (AOR). An AOR < 1 indicates that risk rates are lower with LMWH than with aspirin. In all, 36 159 patients (23.1%) were prescribed aspirin and 120 639 patients (76.9%) were prescribed LMWH. We found no statistically significant differences between the aspirin and LMWH groups in the rate of pulmonary embolism (0.49% vs 0.45%, AOR 0.88 (95% confidence interval (CI) 0.74 to 1.05); p = 0.16), 90-day mortality (0.39% vs 0.45%, AOR 1.13 (95% CI 0.94 to 1.37); p = 0.19) or major haemorrhage (0.37% vs 0.39%, AOR 1.01 (95% CI 0.83 to 1.22); p = 0.94). There was a significantly greater likelihood of needing to return to theatre in the aspirin group (0.26% vs 0.19%, AOR 0.73 (95% CI 0.58 to 0.94); p = 0.01). Between patients receiving LMWH or aspirin there was only a small difference in the risk of pulmonary embolism, 90-day mortality and major haemorrhage. These results should be considered when the existing guidelines for thromboprophylaxis after knee replacement are reviewed


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1649 - 1656
1 Dec 2014
Lindberg-Larsen M Jørgensen CC Bæk Hansen T Solgaard S Odgaard A Kehlet H

We present detailed information about early morbidity after aseptic revision knee replacement from a nationwide study. All aseptic revision knee replacements undertaken between 1st October 2009 and 30th September 2011 were analysed using the Danish National Patient Registry with additional information from the Danish Knee Arthroplasty Registry. The 1218 revisions involving 1165 patients were subdivided into total revisions, large partial revisions, partial revisions and revisions of unicondylar replacements (UKR revisions). The mean age was 65.0 years (27 to 94) and the median length of hospital stay was four days (interquartile range: 3 to 5), with a 90 days re-admission rate of 9.9%, re-operation rate of 3.5% and mortality rate of 0.2%. The age ranges of 51 to 55 years (p = 0.018), 76 to 80 years (p < 0.001) and ≥ 81 years (p < 0.001) were related to an increased risk of re-admission. The age ranges of 76 to 80 years (p = 0.018) and the large partial revision subgroup (p = 0.073) were related to an increased risk of re-operation. The ages from 76 to 80 years (p < 0.001), age ≥ 81 years (p < 0.001) and surgical time > 120 min (p <  0.001) were related to increased length of hospital stay, whereas the use of a tourniquet (p = 0.008) and surgery in a low volume centre (p = 0.013) were related to shorter length of stay. . In conclusion, we found a similar incidence of early post-operative morbidity after aseptic knee revisions as has been reported after primary procedures. This suggests that a length of hospital stay ≤ four days and discharge home at that time is safe following aseptic knee revision surgery in Denmark. Cite this article: Bone Joint J 2014;96-B:1649–56


Bone & Joint Research
Vol. 5, Issue 7 | Pages 280 - 286
1 Jul 2016
Ozkurt B Sen T Cankaya D Kendir S Basarır K Tabak Y

Objectives. The purpose of this study was to develop an accurate, reliable and easily applicable method for determining the anatomical location of the joint line during revision knee arthroplasty. Methods. The transepicondylar width (TEW), the perpendicular distance between the medial and lateral epicondyles and the distal articular surfaces (DMAD, DLAD) and the distance between the medial and lateral epicondyles and the posterior articular surfaces (PMAD, DLAD) were measured in 40 knees from 20 formalin-fixed adult cadavers (11 male and nine female; mean age at death 56.9 years, . sd. 9.4; 34 to 69). The ratios of the DMAD, PMAD, DLAD and PLAD to TEW were calculated. Results. The mean TEW, DMAD, PMAD, DLAD and PLAD were 82.76 mm (standard deviation (. sd. ) 7.74), 28.95 mm (. sd. 3.3), 28.57 mm (. sd. 3), 23.97 mm (. sd. 3.27) and 24.42 mm (. sd. 3.14), respectively. The ratios between the TEW and the articular distances (DMAD/TEW, DLAD/TEW, PMAD/TEW and PLAD/TEW) were calculated and their means were 0.35 (. sd. 0.02), 0.34 (. sd. 0.02), 0.28 (. sd. 0.03) and 0.29 (. sd. 0.03), respectively. Conclusion. This method provides a simple, reproducible and reliable technique enabling accurate anatomical joint line restoration during revision total knee arthroplasty. Cite this article: B. Ozkurt, T. Sen, D. Cankaya, S. Kendir, K. Basarır, Y. Tabak. The medial and lateral epicondyle as a reliable landmark for intra-operative joint line determination in revision knee arthroplasty. Bone Joint Res 2016;5:280–286. DOI: 10.1302/2046-3758.57.BJR-2016-0002.R1


Bone & Joint Research
Vol. 10, Issue 8 | Pages 467 - 473
2 Aug 2021
Rodríguez-Collell JR Mifsut D Ruiz-Sauri A Rodríguez-Pino L González-Soler EM Valverde-Navarro AA

Aims

The main objective of this study is to analyze the penetration of bone cement in four different full cementation techniques of the tibial tray.

Methods

In order to determine the best tibial tray cementation technique, we applied cement to 40 cryopreserved donor tibiae by four different techniques: 1) double-layer cementation of the tibial component and tibial bone with bone restrictor; 2) metallic cementation of the tibial component without bone restrictor; 3) bone cementation of the tibia with bone restrictor; and 4) superficial bone cementation of the tibia and metallic keel cementation of the tibial component without bone restrictor. We performed CT exams of all 40 subjects, and measured cement layer thickness at both levels of the resected surface of the epiphysis and the endomedular metaphyseal level.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1640 - 1644
1 Dec 2013
Agarwal S Azam A Morgan-Jones R

Bone loss in the proximal tibia and distal femur is frequently encountered in revision knee replacement surgery. The various options for dealing with this depend on the extent of any bone loss. We present our results with the use of cementless metaphyseal metal sleeves in 103 patients (104 knees) with a mean follow-up of 43 months (30 to 65). At final follow-up, sleeves in 102 knees had good osseointegration. Two tibial sleeves were revised for loosening, possibly due to infection. The average pre-operative Oxford Knee Score was 23 (11 to 36) and this improved to 32 (15 to 46) post-operatively. These early results encourage us to continue with the technique and monitor the outcomes in the long term. . Cite this article: Bone Joint J 2013;95-B:1640–4


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 738 - 744
1 Jun 2008
Pang H Lo N Yang K Chong H Yeo S

We have performed a prospective double-blind, randomised controlled trial over two years to evaluate the efficacy and safety of an intra-operative peri-articular injection of triamcinolone acetonide in patients undergoing medial unicondylar knee replacement. We randomised 90 patients into two equal groups. The study group received an injection of triamcinolone acetonide, bupivacaine, and epinephrine into the peri-articular tissues at the end of the operation. The control group received the same injection mixture but without the addition of triamcinolone. The peri-operative analgesic regimen was standardised. The study group reported a significant reduction in pain (p = 0.014 at 12 hours, p = 0.031 at 18 hours and p = 0.031 at 24 hours) and had a better range of movement (p = 0.023 at three months). There was no significant difference in the rate of infection and no incidence of tendon rupture in either group. The addition of corticosteroid to the peri-articular injection after unicondylar knee replacement had both immediate and short-term benefits in terms of relief from pain, and rehabilitation with no increased risk of infection


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 619 - 626
1 Apr 2021
Tolk JJ Janssen RPA Haanstra TM van der Steen MC Bierma-Zeinstra SMA Reijman M

Aims

Meeting preoperative expectations is known to be of major influence on postoperative satisfaction after total knee arthroplasty (TKA). Improved management of expectation, resulting in more realistic expectations can potentially lead to higher postoperative satisfaction. The objective of this study was to assess the effect of an additional preoperative education module, addressing realistic expectations for long-term functional recovery, on postoperative satisfaction and expectation fulfilment.

Methods

In total, 204 primary TKA patients with osteoarthritis were enrolled in this randomized controlled trial (RCT). Patients were allocated to either usual preoperative education (control group) or usual education plus an additional module on realistic expectations (intervention group). Primary outcome was being very satisfied (numerical rating scale for satisfaction ≥ 8) with the treatment result at 12 months' follow-up. Other outcomes were change in preoperative expectations and postoperative expectation fulfilment.


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 376 - 385
1 Mar 2022
Gramlich Y Hofmann L Kress S Ruckes C Kemmerer M Klug A Hoffmann R Kremer M

Aims

This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant.

Methods

A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 148 - 152
1 Nov 2013
Dunbar MJ Richardson G Robertsson O

Satisfaction is increasingly employed as an outcome measure for a successful total knee replacement (TKR). Satisfaction as an outcome measure encompasses many different intrinsic and extrinsic factors related to a person’s experience before and after TKR. The Swedish Knee Arthroplasty Registry has previously demonstrated on a large population study that 17% of TKR recipients are not satisfied with their TKR outcome. This finding has been replicated in other countries. Similar significant factors emerged from these registry studies that are related to satisfaction. It would appear that satisfaction is better after more chronic diseases and whether the TKR results in pain relief or improved function. Importantly, unmet pre-operative expectations are a significant predictor for dissatisfaction following a TKR. It may be possible to improve rates by addressing the issues surrounding pain, function and expectation before embarking on surgery. Cite this article: Bone Joint J 2013;95-B, Supple A:148–52


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 38 - 44
1 Jan 2013
Williams DP Price AJ Beard DJ Hadfield SG Arden NK Murray DW Field RE

We present a comparison of patient-reported outcomes (PROMs) in relation to patient age, in patients who had received a total (TKR) or unicompartmental knee replacement (UKR). The outcome was evaluated using the Oxford knee score (OKS), EuroQol (EQ-5D) and satisfaction scores. Patients aged 65 to 84 years demonstrated better pre-operative function scores than those aged < 65 years (OKS, p = 0.03; EQ-5D, p = 0.048) and those aged ≥ 85 years (OKS, p = 0.03). Post-operative scores were comparable across age groups, but a linear trend for greater post-operative improvement in OKS and EQ-5D was seen with decreasing age (p < 0.033). The overall mean satisfaction score at six months was 84.9, but those aged <  55 years exhibited a lower mean level of satisfaction (78.3) compared with all other age groups (all p < 0.031). The cumulative overall two-year revision rate was 1.3%. This study demonstrates that good early outcomes, as measured by the OKS and EQ-5D, can be anticipated following knee replacement regardless of the patient’s age, although younger patients gain greater improvement. However, the lower satisfaction in those aged < 55 years is a concern, and suggests that outcome is not fully encapsulated by the OKS and EQ-5D evaluation, and raises the question whether the OKS alone is an appropriate measure of pain and function in younger, more active individuals. Cite this article: Bone Joint J 2013;95-B:38–44


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1331 - 1340
3 Oct 2020
Attard V Li CY Self A Mann DA Borthwick LA O’Connor P Deehan DJ Kalson NS

Aims

Stiffness is a common complication after total knee arthroplasty (TKA). Pathogenesis is not understood, treatment options are limited, and diagnosis is challenging. The aim of this study was to investigate if MRI can be used to visualize intra-articular scarring in patients with stiff, painful knee arthroplasties.

Methods

Well-functioning primary TKAs (n = 11), failed non-fibrotic TKAs (n = 5), and patients with a clinical diagnosis of fibrosis1 (n = 8) underwent an MRI scan with advanced metal suppression (Slice Encoding for Metal Artefact Correction, SEMAC) with gadolinium contrast. Fibrotic tissue (low intensity on T1 and T2, low-moderate post-contrast enhancement) was quantified (presence and tissue thickness) in six compartments: supra/infrapatella, medial/lateral gutters, and posterior medial/lateral.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 372 - 377
1 Apr 2004
Chauhan SK Scott RG Breidahl W Beaver RJ

We have compared a new technique of computer-assisted knee arthroplasty with the current conventional jig-based technique in 70 patients randomly allocated to receive either of the methods. Post-operative CT was performed according to the Perth CT Knee Arthroplasty protocol and pre- and post-operative Maquet views of the limb were taken. Intra-operative and peri-operative morbidity data were collected and blood loss measured. Post-operative CT showed a significant improvement in the alignment of the components using computer-assisted surgery in regard to femoral varus/valgus (p = 0.032), femoral rotation (p = 0.001), tibial varus/valgus (p = 0.047) tibial posterior slope (p = 0.0001), tibial rotation (p = 0.011) and femorotibial mismatch (p = 0.037). Standing alignment was also improved (p = 0.004) and blood loss was less (p = 0.0001). Computer-assisted surgery took longer with a mean increase of 13 minutes (p = 0.0001)


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1572 - 1578
1 Dec 2018
Middleton R Wilson HA Alvand A Abram SGF Bottomley N Jackson W Price A

Aims

Our unit was identified as a negative outlier in the national patient-reported outcome measures (PROMs) programme, which has significant funding implications. As a centre that carries out a high volume of unicompartmental knee arthroplasty (UKA), our objectives were: 1) to determine whether the PROMs programme included primary UKA when calculating the gain in Oxford Knee Score (OKS); and 2) to determine the impact of excluding primary UKA on calculated OKS gains for primary knee arthroplasty.

Materials and Methods

National PROMs data from England (2012 to 2016) were analyzed. Inclusion of UKA cases in the national PROMs programme was determined using clinical codes. Local OKS gain was calculated for UKA and TKA and compared with the published PROMs results for 2012/13.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 137 - 144
1 Jun 2021
Lachiewicz PF Steele JR Wellman SS

Aims

To establish our early clinical results of a new total knee arthroplasty (TKA) tibial component introduced in 2013 and compare it to other designs in use at our hospital during the same period.

Methods

This is a retrospective study of 166 (154 patients) consecutive cemented, fixed bearing, posterior-stabilized (PS) TKAs (ATTUNE) at one hospital performed by five surgeons. These were compared with a reference cohort of 511 knees (470 patients) of other designs (seven manufacturers) performed at the same hospital by the same surgeons. There were no significant differences in age, sex, BMI, or follow-up times between the two cohorts. The primary outcome was revision performed or pending.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 599 - 603
1 May 2007
Robertsson O Stefánsdòttir A Lidgren L Ranstam J

Patients with osteoarthritis undergoing knee replacement have been reported to have an overall reduced mortality compared with that of the general population. This has been attributed to the selection of healthier patients for surgery. However, previous studies have had a maximum follow-up time of ten years. We have used information from the Swedish Knee Arthroplasty Register to study the mortality of a large national series of patients with total knee replacement for up to 28 years after surgery and compared their mortality with that of the normal population. In addition, for a subgroup of patients operated on between 1980 and 2002 we analysed their registered causes of death to determine if they differed from those expected. We found a reduced overall mortality during the first 12 post-operative years after which it increased and became significantly higher than that of the general population. Age-specific analysis indicated an inverse correlation between age and mortality, where the younger the patients were, the higher their mortality. The shift at 12 years was caused by a relative over-representation of younger patients with a longer follow-up. Analysis of specific causes of death showed a higher mortality for cardiovascular, gastrointestinal and urogenital diseases. The observation that early onset of osteoarthritis of the knee which has been treated by total knee replacement is linked to an increased mortality should be a reason for increased general awareness of health problems in these patients


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 3 - 9
1 Jun 2020
Yang J Parvizi J Hansen EN Culvern CN Segreti JC Tan T Hartman CW Sporer SM Della Valle CJ

Aims. The aim of this study was to determine if a three-month course of microorganism-directed oral antibiotics reduces the rate of failure due to further infection following two-stage revision for chronic prosthetic joint infection (PJI) of the hip and knee. Methods. A total of 185 patients undergoing a two-stage revision in seven different centres were prospectively enrolled. Of these patients, 93 were randomized to receive microorganism-directed oral antibiotics for three months following reimplantation; 88 were randomized to receive no antibiotics, and four were withdrawn before randomization. Of the 181 randomized patients, 28 were lost to follow-up, six died before two years follow-up, and five with culture negative infections were excluded. The remaining 142 patients were followed for a mean of 3.3 years (2.0 to 7.6) with failure due to a further infection as the primary endpoint. Patients who were treated with antibiotics were also assessed for their adherence to the medication regime and for side effects to antibiotics. Results. Nine of 72 patients (12.5%) who received antibiotics failed due to further infection compared with 20 of 70 patients (28.6%) who did not receive antibiotics (p = 0.012). Five patients (6.9%) in the treatment group experienced adverse effects related to the administered antibiotics severe enough to warrant discontinuation. Conclusion. This multicentre randomized controlled trial showed that a three-month course of microorganism-directed, oral antibiotics significantly reduced the rate of failure due to further infection following a two-stage revision of total hip or knee arthroplasty for chronic PJI. Cite this article: Bone Joint J 2020;102-B(6 Supple A):3–9


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 11 - 15
1 Oct 2016
Konan S Haddad FS

Aims. Medial unicompartmental knee arthroplasty (UKA) is associated with successful outcomes in carefully selected patient cohorts. We hypothesised that severity and location of patellofemoral cartilage lesions significantly influences functional outcome after Oxford medial compartmental knee arthroplasty. Patients and Methods. We reviewed 100 consecutive UKAs at minimum eight-year follow-up (96 to 132). A single surgeon performed all procedures. Patients were selected based on clinical and plain radiographic assessment. All patients had end-stage medial compartment osteoarthritis (OA) with sparing of the lateral compartment and intact anterior cruciate ligaments. None of the patients had end-stage patellofemoral OA, but patients with anterior knee pain or partial thickness chondral loss were not excluded. There were 57 male and 43 female patients. The mean age at surgery was 69 years (41 to 82). At surgery the joint was carefully inspected for patellofemoral chondral loss and this was documented based on severity of cartilage loss (0 to 4 Outerbridge grading) and topographic location (medial, lateral, central, and superior or inferior). Functional scores collected included Oxford Knee Score (OKS), patient satisfaction scale and University College Hospital (UCH) knee score. Intraclass correlation was used to compare chondral damage to outcomes. Results. All patients documented significant improvement in pain and improved functional scores at mid-term follow-up. There were four revisions (mean 2.9 years, 2 to 4; standard deviation (. sd). 0.9) in this cohort, three for tibial loosening and one for femoral loosening. There was one infection that was treated with debridement and insert exchange. The mean OKS improved from 23.2 (. sd. 7.1) to 39.1 (. sd. 6.9); p < 0.001. The cohort with central and lateral grade 3 patellofemoral OA documented lower mean satisfaction with pain (90, . sd.  11.8) and function (87.5, . sd. 10.3) on the patient satisfaction scale. On the UCH scale, patients reported significantly decreased mean overall scores (7.3, . sd. 1.2 vs 9, . sd. 2.3) as well as stair climb task (3.5, . sd. 0.3 vs 5, . sd. 0.1) when cartilage lesions were located centrally or laterally on the PFJ. Patients with medial chondral PFJ lesions behave similar to patients with no chondral lesions. Conclusion. Topographical location and severity of cartilage damage of the patella can significantly influence function after successful Oxford medial UKA. Surgeons should factor this in when making their operative decision, and undertake to counsel patients appropriately. Cite this article: Bone Joint J 2016;98-B(10 Suppl B):11–15


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 316 - 322
1 Mar 2007
Pearse EO Caldwell BF Lockwood RJ Hollard J

We carried out an audit on the result of achieving early walking in total knee replacement after instituting a new rehabilitation protocol, and assessed its influence on the development of deep-vein thrombosis as determined by Doppler ultrasound scanning on the fifth post-operative day. Early mobilisation was defined as beginning to walk less than 24 hours after knee replacement. Between April 1997 and July 2002, 98 patients underwent a total of 125 total knee replacements. They began walking on the second post-operative day unless there was a medical contraindication. They formed a retrospective control group. A protocol which allowed patients to start walking at less than 24 hours after surgery was instituted in August 2002. Between August 2002 and November 2004, 97 patients underwent a total of 122 total knee replacements. They formed the early mobilisation group, in which data were prospectively gathered. The two groups were of similar age, gender and had similar medical comorbidities. The surgical technique and tourniquet times were similar and the same instrumentation was used in nearly all cases. All the patients received low-molecular-weight heparin thromboprophylaxis and wore compression stockings post-operatively. In the early mobilisation group 90 patients (92.8%) began walking successfully within 24 hours of their operation. The incidence of deep-vein thrombosis fell from 27.6% in the control group to 1.0% in the early mobilisation group (chi-squared test, p < 0.001). There was a difference in the incidence of risk factors for deep-vein thrombosis between the two groups. However, multiple logistic regression analysis showed that the institution of an early mobilisation protocol resulted in a 30-fold reduction in the risk of post-operative deep-vein thrombosis when we adjusted for other risk factors


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 24 - 26
1 Jan 1999
Vyskocil P Gerber C Bamert P

The radiolucent lines and the stability of the components of 66 knee arthroplasties were assessed by six orthopaedic surgeons on conventional anteroposterior and lateral radiographs and on fluoroscopic views which had been taken on the same day. The examiners were blinded as to the patients and clinical results. The interpretation of the radiographs was repeated after five months. On fluoroscopically-assisted radiographs four of the six examiners identified significantly more radiolucent lines for the femoral component (p < 0.05) and one significantly more for the tibial implant. Five examiners rated more femoral components as radiologically loose on fluoroscopically-assisted radiographs (p = 0.0008 to 0.0154), but none did so for the tibial components. The mean intra- and interobserver kappa values were higher for fluoroscopically-assisted radiographs for both components. We have shown that fluoroscopically-assisted radiographs allow more reproducible, and therefore reliable, detection of radiolucent lines in total knee arthroplasty. Assessment of the stability of the components is significantly influenced by the radiological technique used. Conventional radiographs are not adequate for evaluation of the stability of total knee arthroplasty and should be replaced by fluoroscopically-assisted films


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 366 - 371
1 Apr 2004
Nabeyama R Matsuda S Miura H Mawatari T Kawano T Iwamoto Y

Our study evaluated the accuracy of an image-guided total knee replacement system based on CT with regard to preparation of the femoral and tibial bone using nine limbs from five cadavers. The accuracy was assessed by direct measurement using an extramedullary alignment rod without radiographs. The mean angular errors of the femur and tibia, which represent angular gaps from the real mechanical axis in the coronal plane, were 0.3° and 1.1°, respectively. The CT-based system, provided almost perfect alignment of the femoral component with less than 1° of error and excellent alignment with less than 3° of error for the tibial component. Our results suggest that standardisation of knee replacement by the use of this system will lead to improved long-term survival of total knee arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 334 - 338
1 Mar 2012
Hooper GJ Maxwell AR Wilkinson B Mathew J Woodfield TBF Penny ID Burn PJ Frampton C

We carried out a prospective investigation into the radiological outcomes of uncemented Oxford medial compartment unicondylar replacement in 220 consecutive patients (231 knees) performed in a single centre with a minimum two-year follow-up. The functional outcomes using the mean Oxford knee score and the mean high-activity arthroplasty score were significantly improved over the pre-operative scores (p < 0.001). There were 196 patients with a two-year radiological examination performed under fluoroscopic guidance, aiming to provide images acceptable for analysis of the bone–implant interface. Of the six tibial zones examined on each knee on the anteroposterior radiograph, only three had a partial radiolucent line. All were in the medial aspect of the tibial base plate (zone 1) and all measured < 1 mm. All of these patients were asymptomatic. There were no radiolucent lines seen around the femoral component or on the lateral view. There was one revision for loosening at one year due to initial inadequate seating of the tibial component. These results confirm that the early uncemented Oxford medial unicompartmental compartmental knee replacements were reliable and the incidence of radiolucent lines was significantly decreased compared with the reported results of cemented versions of this implant. These independent results confirm those of the designing centre


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1579 - 1584
1 Dec 2018
Turgeon TR Gascoyne TC Laende EK Dunbar MJ Bohm ER Richardson CG

Aims

The introduction of a novel design of total knee arthroplasty (TKA) must achieve outcomes at least as good as existing designs. A novel design of TKA with a reducing radius of the femoral component and a modified cam-post articulation has been released and requires assessment of the fixation to bone. Radiostereometric analysis (RSA) of the components within the first two postoperative years has been shown to be predictive of medium- to long-term fixation. The aim of this study was to assess the stability of the tibial component of this system during this period of time using RSA.

Patients and Methods

A cohort of 30 patients underwent primary, cemented TKA using the novel posterior stabilized fixed-bearing (ATTUNE) design. There was an even distribution of men and women (15:15). The mean age of the patients was 64 years (sd 8) at the time of surgery; their mean body mass index (BMI) was 35.4 kg/m2 (sd 7.9). RSA was used to assess the stability of the tibial component at 6, 12, and 24 months compared with a six-week baseline examination. Patient-reported outcome measures were also assessed.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 195 - 199
1 Mar 2004
Patel JV Masonis JL Guerin J Bourne RB Rorabeck CH

We report the five- to-ten year results of Anderson Orthopaedic Research Institute type-2 bone defects treated with modular metal augments in revision knee surgery. A total of 102 revision knee arthroplasties in patients with type-2 defects treated with augments and stems were prospectively studied. Seven patients (seven knees) had incomplete follow-up and 15 patients (16 knees) died with the arthroplasty in situ. The mean follow-up of the 79 remaining knees was 7 ± 2 years (5 to 11). The presence of non-progressive radiolucent lines around the augment in 14% of knees was not associated with poorer knee scores, the range of movement, survival of the component or the type of insert which was used (p > 0.05). The survival of the components was 92 ± 0.03% at 11 years (95% CI, 10.3 to 11.2). We recommend the use of modular augmentation devices to treat type-2 defects in revision knee surgery


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 211 - 217
1 Feb 2017
Sluis GVD Goldbohm RA Elings JE Sanden MWND Akkermans RP Bimmel R Hoogeboom TJ Meeteren NLV

Aims . To investigate whether pre-operative functional mobility is a determinant of delayed inpatient recovery of activities (IRoA) after total knee arthroplasty (TKA) in three periods that coincided with changes in the clinical pathway. Patients and Methods. All patients (n = 682, 73% women, mean age 70 years, standard deviation 9) scheduled for TKA between 2009 and 2015 were pre-operatively screened for functional mobility by the Timed-up-and-Go test (TUG) and De Morton mobility index (DEMMI). The cut-off point for delayed IRoA was set on the day that 70% of the patients were recovered, according to the Modified Iowa Levels of Assistance Scale (mILAS) (a 5-item activity scale). In a multivariable logistic regression analysis, we added either the TUG or the DEMMI to a reference model including established determinants. Results. Both the TUG (Odds Ratio (OR) 1.10 per second, 95% confidence intervals (CI) 1.06 to 1.15) and the DEMMI (OR 0.96 per point on the 100-point scale, 95% CI 0.95 to 0.98) were statistically significant determinants of delayed IRoA in a model that also included age, BMI, ASA score and ISAR score. These associations did not depend on the time period during which the TKA took place, as assessed by tests for interaction. . Conclusion. Functional mobility, as assessed pre-operatively by the TUG and DEMMI, is an independent and stable determinant of delayed inpatient recovery of activities after TKA. Future research, focusing on improvement of pre-operative functional mobility through tailored physiotherapy intervention, should indicate whether such intervention enhances post-operative recovery among high-risk patients. Cite this article: Bone Joint J 2017;99-B:211–17