Advertisement for orthosearch.org.uk
Results 1 - 22 of 22
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 120 - 125
1 Jan 2000
Lan F Wunder JS Griffin AM Davis AM Bell RS White LM Ichise M Cole W

We used dual-energy x-ray absorptiometry (DEXA) to evaluate the extent of periprosthetic bone remodelling around a prosthesis for distal femoral reconstruction, the Kotz modular femoral tibial replacement (KMFTR; Howmedica, Rutherford, New Jersey). A total of 23 patients was entered into the study which had four parts: 1) 17 patients were scanned three times on both the implant and contralateral legs to determine whether the precision of DEXA measurements was adequate to estimate bone loss surrounding the anchorage piece of the KMFTR; 2) in 23 patients the bone mineral density (BMD) in different regions of interest surrounding the diaphyseal anchorage was compared with that of the contralateral femur at the same location to test whether there was consistent evidence of loss of BMD adjacent to the prosthetic stem; 3) in 12 patients sequential studies were performed about one year apart to compare bone loss; and 4) bone loss was compared in ten patients with implants fixed by three screws and in 13 without screws.

The mean coefficients of variation (SD/mean) for the 17 sets of repeated scans ranged from 2.9% to 7.8% at different regions of interest in the KMFTR leg and from 1.4% to 2.5% in the contralateral leg. BMD was decreased in the KMFTR leg relative to the contralateral limb and the percentage of BMD loss in general increased as the region of interest moved distally in the femur. Studies done after one year showed no consistent pattern of progressive bone loss between the two measurements. The ten patients with implants fixed by screws were found to have a mean loss of BMD of 42% in the most distal part of the femur, while the 13 without screw fixation had a mean loss of 11%.

DEXA was shown to have adequate precision to evaluate loss of BMD around the KMFTR. This was evident relative to the contralateral leg in all patients and generally increased in the most distal part of the femur. In general, it stabilised between two measurements taken one year apart and was greater surrounding implants fixed by cross-locking screws.


Bone & Joint Open
Vol. 5, Issue 4 | Pages 317 - 323
18 Apr 2024
Zhu X Hu J Lin J Song G Xu H Lu J Tang Q Wang J

Aims. The aim of this study was to investigate the safety and efficacy of 3D-printed modular prostheses in patients who underwent joint-sparing limb salvage surgery (JSLSS) for malignant femoral diaphyseal bone tumours. Methods. We retrospectively reviewed 17 patients (13 males and four females) with femoral diaphyseal tumours who underwent JSLSS in our hospital. Results. In all, 17 patients with locally aggressive bone tumours (Enneking stage IIB) located in the femoral shaft underwent JSLSS and reconstruction with 3D-printed modular prostheses between January 2020 and June 2022. The median surgical time was 153 minutes (interquartile range (IQR) 117 to 248), and the median estimated blood loss was 200ml (IQR 125 to 400). Osteosarcoma was the most common pathological type (n = 12; 70.6%). The mean osteotomy length was 197.53 mm (SD 12.34), and the median follow-up was 25 months (IQR 19 to 38). Two patients experienced local recurrence and three developed distant metastases. Postoperative complications included wound infection in one patient and screw loosening in another, both of which were treated successfully with revision surgery. The median Musculoskeletal Tumor Society score at the final follow-up was 28 (IQR 27 to 28). Conclusion. The 3D-printed modular prosthesis is a reliable and feasible reconstruction option for patients with malignant femoral diaphyseal tumours. It helps to improve the limb salvage rate, restore limb function, and achieve better short-term effectiveness. Cite this article: Bone Jt Open 2024;5(4):317–323


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 836 - 841
1 Jun 2012
Frisoni T Cevolani L Giorgini A Dozza B Donati DM

We retrospectively reviewed 101 consecutive patients with 114 femoral tumours treated by massive bone allograft at our institution between 1986 and 2005. There were 49 females and 52 males with a mean age of 20 years (4 to 74). At a median follow-up of 9.3 years (2 to 19.8), 36 reconstructions (31.5%) had failed. The allograft itself failed in 27 reconstructions (24%). Mechanical complications such as delayed union, fracture and failure of fixation were studied. The most adverse factor on the outcome was the use of intramedullary nails, followed by post-operative chemotherapy, resection length > 17 cm and age > 18 years at the time of intervention. The simultaneous use of a vascularised fibular graft to protect the allograft from mechanical complications improved the outcome, but the use of intramedullary cementing was not as successful. In order to improve the strength of the reconstruction and to advance the biology of host–graft integration, we suggest avoiding the use of intramedullary nails and titanium plates, but instead using stainless steel plates, as these gave better results. The use of a supplementary vascularised fibular graft should be strongly considered in adult patients with resection > 17 cm and in those who require post-operative chemotherapy


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 101 - 108
1 Jan 2018
Stevenson JD Kumar VS Cribb GL Cool P

Aims

Dislocation rates are reportedly lower in patients requiring proximal femoral hemiarthroplasty than for patients undergoing hip arthroplasty for neoplasia. Without acetabular replacement, pain due to acetabular wear necessitating revision surgery has been described. We aimed to determine whether wear of the native acetabulum following hemiarthroplasty necessitates revision surgery with secondary replacement of the acetabulum after proximal femoral replacement (PFR) for tumour reconstruction.

Patients and Methods

We reviewed 100 consecutive PFRs performed between January 2003 and January 2013 without acetabular resurfacing. The procedure was undertaken in 74 patients with metastases, for a primary bone tumour in 20 and for myeloma in six. There were 48 male and 52 female patients, with a mean age of 61.4 years (19 to 85) and median follow-up of two years (interquartile range (IQR) 0.5 to 3.7 years). In total, 52 patients presented with a pathological fracture and six presented with failed fixation of a previously instrumented pathological fracture.


Bone & Joint 360
Vol. 13, Issue 4 | Pages 35 - 37
2 Aug 2024

The August 2024 Oncology Roundup. 360. looks at: What factors are associated with osteoarthritis after cementation for benign aggressive bone tumour of the knee joint: a systematic review and meta-analysis; Recycled bone grafts treated with extracorporeal irradiation or liquid nitrogen freezing after malignant tumour resection; Intercalary resection of the tibia for primary bone tumours: are vascularized fibula autografts with or without allografts a durable reconstruction?; 3D-printed modular prostheses for the reconstruction of intercalary bone defects after joint-sparing limb salvage surgery for femoral diaphyseal tumours; Factors influencing the outcome of patients with primary Ewing’s sarcoma of the sacrum; The significance of surveillance imaging in children with Ewing’s sarcoma and osteosarcoma; Resection margin and soft-tissue sarcomas of the extremities treated with limb-sparing surgery and postoperative radiotherapy


Bone & Joint Open
Vol. 5, Issue 4 | Pages 260 - 268
1 Apr 2024
Broekhuis D Meurs WMH Kaptein BL Karunaratne S Carey Smith RL Sommerville S Boyle R Nelissen RGHH

Aims

Custom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research focusing on tumour cases and implant flange positioning precision remains limited. Additionally, the impact of intraoperative navigation on positioning accuracy warrants further investigation. This study assesses CTAC positioning accuracy in tumour resection and rTHA cases, focusing on the differences between preoperative planning and postoperative implant positions.

Methods

A multicentre observational cohort study in Australia between February 2017 and March 2021 included consecutive patients undergoing acetabular reconstruction with CTACs in rTHA (Paprosky 3A/3B defects) or tumour resection (including Enneking P2 peri-acetabular area). Of 103 eligible patients (104 hips), 34 patients (35 hips) were analyzed.


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1174 - 1179
1 Oct 2022
Jamshidi K Bagherifard A Mirzaei A

Aims

Osteoarticular reconstruction of the distal femur in childhood has the advantage of preserving the tibial physis. However, due to the small size of the distal femur, matching the host bone with an osteoarticular allograft is challenging. In this study, we compared the outcomes and complications of a resurfaced allograft-prosthesis composite (rAPC) with those of an osteoarticular allograft to reconstruct the distal femur in children.

Methods

A retrospective analysis of 33 skeletally immature children with a malignant tumour of the distal femur, who underwent resection and reconstruction with a rAPC (n = 15) or osteoarticular allograft (n = 18), was conducted. The median age of the patients was ten years (interquartile range (IQR) 9 to 11) in the osteoarticular allograft group and nine years (IQR 8 to 10) in the rAPC group (p = 0.781). The median follow-up of the patients was seven years (IQR 4 to 8) in the osteoarticular allograft group and six years (IQR 3 to 7) in the rAPC group (p = 0.483). Limb function was evaluated using the Musculoskeletal Tumor Society (MSTS) score.


Bone & Joint Open
Vol. 1, Issue 9 | Pages 585 - 593
24 Sep 2020
Caterson J Williams MA McCarthy C Athanasou N Temple HT Cosker T Gibbons M

Aims

The aticularis genu (AG) is the least substantial and deepest muscle of the anterior compartment of the thigh and of uncertain significance. The aim of the study was to describe the anatomy of AG in cadaveric specimens, to characterize the relevance of AG in pathological distal femur specimens, and to correlate the anatomy and pathology with preoperative magnetic resonance imaging (MRI) of AG.

Methods

In 24 cadaveric specimens, AG was identified, photographed, measured, and dissected including neurovascular supply. In all, 35 resected distal femur specimens were examined. AG was photographed and measured and its utility as a surgical margin examined. Preoperative MRIs of these cases were retrospectively analyzed and assessed and its utility assessed as an anterior soft tissue margin in surgery. In all cadaveric specimens, AG was identified as a substantial structure, deep and separate to vastus itermedius (VI) and separated by a clear fascial plane with a discrete neurovascular supply. Mean length of AG was 16.1 cm ( ± 1.6 cm) origin anterior aspect distal third femur and insertion into suprapatellar bursa. In 32 of 35 pathological specimens, AG was identified (mean length 12.8 cm ( ± 0.6 cm)). Where AG was used as anterior cover in pathological specimens all surgical margins were clear of disease. Of these cases, preoperative MRI identified AG in 34 of 35 cases (mean length 8.8 cm ( ± 0.4 cm)).


Bone & Joint 360
Vol. 10, Issue 4 | Pages 40 - 42
1 Aug 2021


Bone & Joint 360
Vol. 9, Issue 5 | Pages 41 - 43
1 Oct 2020


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 1024 - 1031
1 Aug 2019
Fujiwara T Medellin MR Sambri A Tsuda Y Balko J Sumathi V Gregory J Jeys L Abudu A

Aims

The aim of this study was to determine the risk of local recurrence and survival in patients with osteosarcoma based on the proximity of the tumour to the major vessels.

Patients and Methods

A total of 226 patients with high-grade non-metastatic osteosarcoma in the limbs were investigated. Median age at diagnosis was 15 years (4 to 67) with the ratio of male to female patients being 1.5:1. The most common site of the tumour was the femur (n = 103) followed by tibia (n = 66). The vascular proximity was categorized based on the preoperative MRI after neoadjuvant chemotherapy into four types: type 1 > 5 mm; type 2 ≤ 5 mm, > 0 mm; type 3 attached; type 4 surrounded.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 524 - 529
1 Apr 2020
Jamshidi K Mirkazemi M Gharedaghi M Izanloo A Mohammadpour M Pisoudeh K Bagherifard A Mirzaei A

Aims

The consensus is that bipolar hemiarthroplasty (BHA) in allograft-prosthesis composite (APC) reconstruction of the proximal femur following primary tumour resection provides more stability than total hip arthroplasty (THA). However, no comparative study has been performed. In this study, we have compared the outcome and complication rates of these two methods.

Methods

In a retrospective study, 57 patients who underwent APC reconstruction of proximal femur following the primary tumour resection, either using BHA (29) or THA (28), were included. Functional outcome was assessed using the Musculoskeletal Tumour Society (MSTS) scoring system and Harris Hip Score (HHS). Postoperative complications of the two techniques were also compared.


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 732 - 738
1 Jun 2019
Liu Q He H Zeng H Yuan Y Long F Tian J Luo W

Aims

The aim of this study was to evaluate the efficacy of the surgical dislocation approach and modified trapdoor procedure for the treatment of chondroblastoma of the femoral head.

Patients and Methods

A total of 17 patients (ten boys, seven girls; mean age 16.4 years (11 to 26)) diagnosed with chondroblastoma of the femoral head who underwent surgical dislocation of the hip joint, modified trapdoor procedure, curettage, and bone grafting were enrolled in this study and were followed-up for a mean of 35.9 months (12 to 76). Healing and any local recurrence were assessed via clinical and radiological tests. Functional outcome was evaluated using the Musculoskeletal Tumour Society scoring system (MSTS). Patterns of bone destruction were evaluated using the Lodwick classification. Secondary osteoarthritis was classified via radiological analysis following the Kellgren–Lawrence grading system. Steinberg classification was used to evaluate osteonecrosis of the femoral head.


Bone & Joint 360
Vol. 6, Issue 4 | Pages 29 - 31
1 Aug 2017


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 544 - 549
1 Apr 2015
Qu H Guo W Yang R Tang X Yan T Li D Yang Y Zang J

We determined the efficacy of a devitalised autograft (n = 13) and allograft (n = 16) cortical strut bone graft combined with long-stem endoprosthetic reconstruction in the treatment of massive tumours of the lower limb. A total of 29 patients (18 men:11 women, mean age 20.1 years (12 to 45) with a ratio of length of resection to that of the whole prosthesis of > 50% were treated between May 2003 and May 2012. The mean follow-up was 47 months (15 to 132). The stem of the prosthesis was introduced through bone graft struts filled with cement, then cemented into the residual bone. Bone healing was achieved in 23 patients (86%). The mean Musculoskeletal Tumour Society functional score was 85% (57 to 97). The five-year survival rate of the endoprostheses was 81% (95% confidence intervals 67.3 to 92.3). The mean length of devitalised autografts and allografts was 8.6 cm (5 to 15), which increased the ratio of the the length of the stem of the prosthesis to that of the whole length of the prosthesis from a theoretical 35% to an actual 55%.

Cortical strut bone grafting and long-stem endoprosthetic reconstruction is an option for treating massive segmental defects following resection of a tumour in the lower limb. Patients can regain good function with a low incidence of aseptic loosening. The strut graft and the residual bone together serve as a satisfactory bony environment for a revision prosthesis, if required, once union is achieved.

Cite this article: Bone Joint J 2015;97-B:544–9.


Bone & Joint 360
Vol. 1, Issue 5 | Pages 26 - 28
1 Oct 2012

The October 2012 Oncology Roundup360 looks at: the causes of primary bone tumours; adjuvant chemotherapy in the longer term; vascularised fibular grafts to salvage massive femoral allografts; a new look at old risks; reconstruction with excised irradiated bone; predicting chemosensitivity in osteosarcoma ; and chemotherapy, osteoporosis and the risk of fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1084 - 1089
1 Aug 2008
Guo W Ji T Yang R Tang X Yang Y

In developing countries locally-made low-cost prostheses are mainly used in limb-salvage surgery to alleviate the economic burden.

We retrospectively collected data on 104 patients treated by limb-salvage surgery between July 1997 and July 2005. We used a locally-designed and fabricated stainless-steel endoprosthesis in each case. Oncological and functional outcomes were evaluated at a mean follow-up of 47 months (12 to 118).

A total of 73 patients (70.2%) were free from disease, nine (8.7%) were alive with disease, 19 (18.2%) had died from their disease and three (2.9%) from unrelated causes. According to the Musculoskeletal Tumor Society scoring system, the mean functional score was 76.3% (SD 17.8). The five-year survival for the implant was 70.5%. There were nine cases (8.7%) of infection, seven early and two late, seven (6.7%) of breakage of the prosthesis, three (2.9%) of aseptic loosening and two (1.9%) of failure of the polyethylene bushing. Multivariate analysis showed that a proximal tibial prosthesis and a resection length of 14 cm or more were significant negative prognostic factors.

Our survival rates and Musculoskeletal Tumor Society functional scores are similar to those reported in the literature. Although longer follow-up is needed to confirm our results, we believe that a low-cost custom-made endoprosthesis is a cost-effective and reliable reconstructive option for limb salvage in developing countries.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 395 - 400
1 Mar 2005
Hardes J Gosheger G Vachtsevanos L Hoffmann C Ahrens H Winkelmann W

Type BI rotationplasty is currently indicated for children with tumours of the proximal femur whereas type BIIIa rotationplasty is reserved for those in which the entire femur has to be removed. Our aim was to compare these two types of rotationplasty and determine whether the knee should be preserved in children with tumours of the proximal femur. We compared the post-operative complications, oncological outcome, range of movement, Enneking score and radiographs of six children, who had undergone type BI rotationplasty with those of 12 who had undergone type BIIIa rotationplasty.

Patients with type BI rotationplasty had a mean Enneking score of 21.6 compared with 24.4 in those with type BIIIa rotationplasty, and worse mean results in all of the parameters investigated. We conclude that type BI rotationplasty has a worse functional outcome and more complications than type BIIIa rotationplasty in children under the age of ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1223 - 1226
1 Sep 2009
Chowdhry M Hughes C Grimer RJ Sumathi V Wilson S Jeys L

We identified eight patients of 2900 with a primary malignant bone tumour who had coexisting neurofibromatosis type 1. This was a much higher incidence than would be expected by chance. The patients had a mean age of 22.4 years (9 to 54): five were male. Two patients subsequently developed a second bone sarcoma, one of which was radiation induced. Four of the primary tumours were osteosarcomas, four were spindle-cell sarcomas and one a Ewing’s sarcoma. All the patients were treated with chemotherapy and surgery: six of the eight appear to be cured.

This study suggests a possible relationship between neurofibromatosis type 1 and the development of a bone sarcoma, the increased risk being estimated at eight times that of the normal population. We recommend that further research into this possible link should be considered.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1574 - 1579
1 Nov 2010
Hariri A Mascard E Atlan F Germain MA Heming N Dubousset JF Wicart P

We describe a retrospective review of 38 cases of reconstruction following resection of the metaphysiodiaphysis of the lower limb for malignant bone tumours using free vascularised fibular grafts. The mean follow-up was for 7.6 years (0.4 to 18.4). The mean Musculoskeletal Tumor Society score was 27.2 (20 to 30). The score was significantly higher when the graft was carried out in a one-stage procedure after resection of the tumour rather than in two stages. Bony union was achieved in 89% of the cases. The overall mean time to union was 1.7 years (0.2 to 10.3).

Free vascularised fibular transfer is a major operation with frequent, but preventable, complications which allows salvage of the limb with satisfactory functional results.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 867 - 874
1 Jun 2010
Hanna SA Sewell MD Aston WJS Pollock RC Skinner JA Cannon SR Briggs TWR

Segmental resection of malignant bone disease in the femoral diaphysis with subsequent limb reconstruction is a major undertaking. This is a retrospective review of 23 patients who had undergone limb salvage by endoprosthetic replacement of the femoral diaphysis for a primary bone tumour between 1989 and 2005.

There were 16 males and seven females, with a mean age of 41.3 years (10 to 68). The mean overall follow-up was for 97 months (3 to 240), and 120 months (42 to 240) for the living patients. The cumulative patient survival was 77% (95% confidence interval 63% to 95%) at ten years. Survival of the implant, with failure of the endoprosthesis as an endpoint, was 85% at five years and 68% (95% confidence interval 42% to 92%) at ten years. The revision rate was 22% and the overall rate of re-operation was 26%. Complications included deep infection (4%), breakage of the prosthesis (8%), periprosthetic fracture (4%), aseptic loosening (4%), local recurrence (4%) and metastases (17%). The 16 patients who retained their diaphyseal endoprosthesis had a mean Musculoskeletal Tumour Society score of 87% (67% to 93%). They were all able to comfortably perform most activities of daily living.

Femoral diaphyseal endoprosthetic replacement is a viable option for reconstruction following segmental resection of malignant bone disease. It allows immediate weight-bearing, is associated with a good long-term functional outcome, has an acceptable complication and revision rate and, most importantly, does not appear to compromise patient survival.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 943 - 947
1 Jul 2007
Wong KC Kumta SM Chiu KH Antonio GE Unwin P Leung KS

The use of a navigation system in musculoskeletal tumour surgery enables the integration of pre-operative CT and MRI images to generate a precise three-dimensional anatomical model of the site and the extent of the tumour.

We carried out six consecutive resections of musculoskeletal tumour in five patients using an existing commercial computer navigation system. There were three women and two men with a mean age of 41 years (24 to 47). Reconstruction was performed using a tumour prosthesis in three lesions and a vascularised fibular graft in one. No reconstruction was needed in two cases. The mean follow-up was 6.9 months (3.5 to 10). The mean duration of surgery was 28 minutes (13 to 50). Examination of the resected specimens showed clear margins in all the tumour lesions and a resection that was exactly as planned.