Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 677 - 682
1 Jun 2020
Katzouraki G Zubairi AJ Hershkovich O Grevitt MP

Aims. Diagnosis of cauda equina syndrome (CES) remains difficult; clinical assessment has low accuracy in reliably predicting MRI compression of the cauda equina (CE). This prospective study tests the usefulness of ultrasound bladder scans as an adjunct for diagnosing CES. Methods. A total of 260 patients with suspected CES were referred to a tertiary spinal unit over a 16-month period. All were assessed by Board-eligible spinal surgeons and had transabdominal ultrasound bladder scans for pre- and post-voiding residual (PVR) volume measurements before lumbosacral MRI. Results. The study confirms the low predictive value of ‘red flag’ symptoms and signs. Of note ‘bilateral sciatica’ had a sensitivity of 32.4%, and a positive predictive value (PPV) of only 17.2%, and negative predictive value (NPV) 88.3%. Use of a PVR volume of ≥ 200 ml was a demonstrably more accurate test for predicting cauda equina compression on subsequent MRI (p < 0.001). The PVR sensitivity was 94.1%, specificity 66.8%, PPV 29.9% and NPV 98.7%. The PVR allowed risk-stratification with 13% patients deemed ‘low-risk’ of CES. They had non-urgent MRI scans. None of the latter scans showed any cauda equina compression (p < 0.006) or individuals developed subsequent CES in the intervening period. There were considerable cost-savings associated with the above strategy. Conclusion. This is the largest reported prospective evaluation of suspected CES. Use of the PVR volume ≥ 200 ml was considerably more accurate in predicting CES. It is a useful adjunct to conventional clinical assessment and allows risk-stratification in managing suspected CES. If adopted widely it is less likely incomplete CES would be missed. Cite this article: Bone Joint J 2020;102-B(6):677–682


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 739 - 745
1 Apr 2021
Mehta JS Hodgson K Yiping L Kho JSB Thimmaiah R Topiwala U Sawlani V Botchu R

Aims

To benchmark the radiation dose to patients during the course of treatment for a spinal deformity.

Methods

Our radiation dose database identified 25,745 exposures of 6,017 children (under 18 years of age) and adults treated for a spinal deformity between 1 January 2008 and 31 December 2016. Patients were divided into surgical (974 patients) and non-surgical (5,043 patients) cohorts. We documented the number and doses of ionizing radiation imaging events (radiographs, CT scans, or intraoperative fluoroscopy) for each patient. All the doses for plain radiographs, CT scans, and intraoperative fluoroscopy were combined into a single effective dose by a medical physicist (milliSivert (mSv)).


Bone & Joint Open
Vol. 1, Issue 7 | Pages 405 - 414
15 Jul 2020
Abdelaal A Munigangaiah S Trivedi J Davidson N

Aims

Magnetically controlled growing rods (MCGR) have been gaining popularity in the management of early-onset scoliosis (EOS) over the past decade. We present our experience with the first 44 MCGR consecutive cases treated at our institution.

Methods

This is a retrospective review of consecutive cases of MCGR performed in our institution between 2012 and 2018. This cohort consisted of 44 children (25 females and 19 males), with a mean age of 7.9 years (3.7 to 13.6). There were 41 primary cases and three revisions from other rod systems. The majority (38 children) had dual rods. The group represents a mixed aetiology including idiopathic (20), neuromuscular (13), syndromic (9), and congenital (2). The mean follow-up was 4.1 years, with a minimum of two years. Nine children graduated to definitive fusion. We evaluated radiological parameters of deformity correction (Cobb angle), and spinal growth (T1-T12 and T1-S1 heights), as well as complications during the course of treatment.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1187 - 1200
1 Sep 2018
Subramanian T Ahmad A Mardare DM Kieser DC Mayers D Nnadi C

Aims

Magnetically controlled growing rod (MCGR) systems use non-invasive spinal lengthening for the surgical treatment of early-onset scoliosis (EOS). The primary aim of this study was to evaluate the performance of these devices in the prevention of progression of the deformity. A secondary aim was to record the rate of complications.

Patients and Methods

An observational study of 31 consecutive children with EOS, of whom 15 were male, who were treated between December 2011 and October 2017 was undertaken. Their mean age was 7.7 years (2 to 14). The mean follow-up was 47 months (24 to 69). Distractions were completed using the tailgating technique. The primary outcome measure was correction of the radiographic deformity. Secondary outcomes were growth, functional outcomes and complication rates.


Bone & Joint 360
Vol. 3, Issue 5 | Pages 41 - 43
1 Oct 2014
Roberts D Cole AS


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1662 - 1667
1 Dec 2016
Teoh KH von Ruhland C Evans SL James SH Jones A Howes J Davies PR Ahuja S

Aims

We present a case series of five patients who had revision surgery following magnetic controlled growing rods (MGCR) for early onset scoliosis. Metallosis was found during revision in four out of five patients and we postulated a mechanism for rod failure based on retrieval analysis.

Patients and Methods

Retrieval analysis was performed on the seven explanted rods. The mean duration of MCGR from implantation to revision was 35 months (17 to 46). The mean age at revision was 12 years (7 to 15; four boys, one girl).


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 943 - 949
1 Jul 2014
Duckworth AD Mitchell MJ Tsirikos AI

We report the incidence of and risk factors for complications after scoliosis surgery in patients with Duchenne muscular dystrophy (DMD) and compare them with those of other neuromuscular conditions.

We identified 110 (64 males, 46 females) consecutive patients with a neuromuscular disorder who underwent correction of the scoliosis at a mean age of 14 years (7 to 19) and had a minimum two-year follow-up. We recorded demographic and peri-operative data, including complications and re-operations.

There were 60 patients with cerebral palsy (54.5%) and 26 with DMD (23.6%). The overall complication rate was 22% (24 patients), the most common of which were deep wound infection (9, 8.1%), gastrointestinal complications (5, 4.5%) and hepatotoxicity (4, 3.6%). The complication rate was higher in patients with DMD (10/26, 38.5%) than in those with other neuromuscular conditions (14/84, 16.7% (p = 0.019). All hepatotoxicity occurred in patients with DMD (p = 0.003), who also had an increased rate of deep wound infection (19% vs 5%) (p = 0.033). In the DMD group, no peri-operative factors were significantly associated with the rate of overall complications or deep wound infection. Increased intra-operative blood loss was associated with hepatotoxicity (p = 0.036).

In our series, correction of a neuromuscular scoliosis had an acceptable rate of complications: patients with DMD had an increased overall rate compared with those with other neuromuscular conditions. These included deep wound infection and hepatotoxicity. Hepatotoxicity was unique to DMD patients, and we recommend peri-operative vigilance after correction of a scoliosis in this group.

Cite this article: Bone Joint J 2014; 96-B:943–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1546 - 1550
1 Nov 2012
Longo UG Loppini M Romeo G Maffulli N Denaro V

Wrong-level surgery is a unique pitfall in spinal surgery and is part of the wider field of wrong-site surgery. Wrong-site surgery affects both patients and surgeons and has received much media attention. We performed this systematic review to determine the incidence and prevalence of wrong-level procedures in spinal surgery and to identify effective prevention strategies. We retrieved 12 studies reporting the incidence or prevalence of wrong-site surgery and that provided information about prevention strategies. Of these, ten studies were performed on patients undergoing lumbar spine surgery and two on patients undergoing lumbar, thoracic or cervical spine procedures. A higher frequency of wrong-level surgery in lumbar procedures than in cervical procedures was found. Only one study assessed preventative strategies for wrong-site surgery, demonstrating that current site-verification protocols did not prevent about one-third of the cases. The current literature does not provide a definitive estimate of the occurrence of wrong-site spinal surgery, and there is no published evidence to support the effectiveness of site-verification protocols. Further prevention strategies need to be developed to reduce the risk of wrong-site surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1393 - 1398
1 Oct 2012
Mattila M Jalanko T Puisto V Pajulo O Helenius IJ

We compared the clinical, radiological and quality-of-life outcomes between hybrid and total pedicle screw instrumentation in patients undergoing surgery for neuromuscular scoliosis. A matched comparison using prospectively collected data was undertaken. A total of 66 patients underwent posterior or anteroposterior correction and fusion with hybrid (n = 33, mean age at surgery 15.8 years (9.10 to 19.6)) or total pedicle screw instrumentation (n = 33, mean age 14.7 years (7.0 to 20.7)) with a minimum follow-up of two years. The major curve pre-operatively was a mean of 87° (sd 29, 25° to 141°) and 81° (sd 18, 47° to 116°) in the hybrid and total pedicle screw groups, respectively (p = 0.29) and at a minimum of two years it was 33° (sd 20; 2° to 87°) and 20° (sd 12; 1° to 55°), respectively (p = 0.0016). The mean correction of the major curve was 59% (41% to 88%) in the hybrid and 75% (43% to 99%) in the total pedicle screw groups at two-year follow-up (p = 0.0011). The mean operating time was 7.45 hours (sd 2.18) and 6.04 hours (sd 1.71) in the hybrid and total pedicle screw groups, respectively (p = 0.001), and the mean intra-operative blood loss was 3760 ml (sd 2790) and 1785 ml (sd 1110), respectively (p = 0.001).

Total pedicle screw instrumentation provided shorter operating times, less blood loss and better correction of the major curve compared with hybrid constructs in patients undergoing surgery for neuromuscular scoliosis.