Aims. Radiological residual
Aims. Slipped upper femoral epiphysis (SUFE) has well documented biochemical and mechanical risk factors. Femoral and
Aims. Abduction bracing is commonly used to treat developmental dysplasia of the hip (DDH) following closed reduction and spica casting, with little evidence to support or refute this practice. The purpose of this study was to determine the efficacy of abduction bracing after closed reduction in improving
The present study seeks to investigate the correlation of pubofemoral distances (PFD) to α angles, and hip displaceability status, defined as femoral head coverage (FHC) or FHC during manual provocation of the newborn hip < 50%. We retrospectively included all newborns referred for ultrasound screening at our institution based on primary risk factor, clinical, and PFD screening. α angles, PFD, FHC, and FHC at follow-up ultrasound for referred newborns were measured and compared using scatter plots, linear regression, paired Aims
Methods
We carried out a morphometric analysis of
Untreated
Our aim was to determine whether abnormalities noted on MRI immediately after reduction for developmental dysplasia of the hip could predict the persistance of dysplasia and aid surgical planning. Scans of 13 hips in which
Hereditary multiple exostoses is an autosomal dominant disorder characterised by multiple osteochondromata, most commonly affecting the forearm, knee and ankle. Osteochondromata of the proximal femur have been reported to occur in 30% to 90% of affected patients with coxa valga in 25%.
The anatomy and development of the growing acetabulum are not clearly understood. We dissected and studied histologically two acetabula from the pelvis of a three-month-old infant. Relative rates of growth at the different growth plates were assessed by comparing the height of the proliferative layer with that of the hypertrophic layer. The three bones which form the acetabulum are surrounded by growth plates on all sides except medially. These face towards the centre of the triradiate cartilage, the limbs of the triradiate cartilage and the articular surface and each may be divided into four distinct areas according to the orientation of its cell columns which reflect the direction of growth. Growth was particularly rapid at the ischial growth plates directed towards the centre and the articular cartilage, and on both sides of the anterior limb of the triradiate cartilage. These findings may explain the mechanism by which the acetabulum changes orientation and inclination with growth.
Aims. Brace treatment is the cornerstone of managing developmental dysplasia of the hip (DDH), yet there is a lack of evidence-based treatment protocols, which results in wide variations in practice. To resolve this, we have developed a comprehensive nonoperative treatment protocol conforming to published consensus principles, with well-defined a priori criteria for inclusion and successful treatment. Methods. This was a single-centre, prospective, longitudinal cohort study of a consecutive series of infants with ultrasound-confirmed DDH who underwent a comprehensive nonoperative brace management protocol in a unified multidisciplinary clinic between January 2012 and December 2016 with five-year follow-up radiographs. The radiological outcomes were
Aims. Studies of infant hip development to date have been limited by considering only the changes in appearance of a single ultrasound slice (Graf’s standard plane). We used 3D ultrasound (3DUS) to establish maturation curves of normal infant hip development, quantifying variation by age, sex, side, and anteroposterior location in the hip. Methods. We analyzed 3DUS scans of 519 infants (mean age 64 days (6 to 111 days)) presenting at a tertiary children’s hospital for suspicion of developmental dysplasia of the hip (DDH). Hips that did not require ultrasound follow-up or treatment were classified as ‘typically developing’. We calculated traditional DDH indices like α angle (α. SP. ), femoral head coverage (FHC. SP. ), and several novel indices from 3DUS like the
Aims. There is no consensus regarding optimum timing and frequency of ultrasound (US) for monitoring response to Pavlik harness (PH) treatment in developmental dysplasia of the hip (DDH). The purpose of our study was to determine if a limited-frequency hip US assessment had an adverse effect on treatment outcomes compared to traditional comprehensive US monitoring. Methods. This study was a single-centre noninferiority randomized controlled trial. Infants aged under six months whose hips were reduced and centred in the harness at initiation of treatment (stable dysplastic or subluxable), or initially decentred (subluxated or dislocated) but reduced and centred within four weeks of PH treatment, were randomized to our current standard US monitoring protocol (every clinic visit) or to a limited-frequency US protocol (US only at end of treatment). Groups were compared based on α angle and femoral head coverage at the end of PH treatment,
Aims. The diagnosis of developmental dysplasia of the hip (DDH) is challenging owing to extensive variation in paediatric pelvic anatomy. Artificial intelligence (AI) may represent an effective diagnostic tool for DDH. Here, we aimed to develop an anteroposterior pelvic radiograph deep learning system for diagnosing DDH in children and analyze the feasibility of its application. Methods. In total, 10,219 anteroposterior pelvic radiographs were retrospectively collected from April 2014 to December 2018. Clinicians labelled each radiograph using a uniform standard method. Radiographs were grouped according to age and into ‘dislocation’ (dislocation and subluxation) and ‘non-dislocation’ (normal cases and those with dysplasia of the acetabulum) groups based on clinical diagnosis. The deep learning system was trained and optimized using 9,081 radiographs; 1,138 test radiographs were then used to compare the diagnoses made by deep learning system and clinicians. The accuracy of the deep learning system was determined using a receiver operating characteristic curve, and the consistency of
The aim of this study was to investigate the agreement in interpretation of the quality of the paediatric hip ultrasound examination, the reliability of geometric and morphological assessment, and the relationship between these measurements. Four investigators evaluated 60 hip ultrasounds and assessed their quality based the standard plane of Graf et al. They measured geometric parameters, described the morphology of the hip, and assigned the Graf grade of dysplasia. They analyzed one self-selected image and one randomly selected image from the ultrasound series, and repeated the process four weeks later. The intra- and interobserver agreement, and correlations between various parameters were analyzed.Aims
Methods
Hip disease is common in children with cerebral palsy (CP) and can decrease quality of life and function. Surveillance programmes exist to improve outcomes by treating hip disease at an early stage using radiological surveillance. However, studies and surveillance programmes report different radiological outcomes, making it difficult to compare. We aimed to identify the most important radiological measurements and develop a core measurement set (CMS) for clinical practice, research, and surveillance programmes. A systematic review identified a list of measurements previously used in studies reporting radiological hip outcomes in children with CP. These measurements informed a two-round Delphi study, conducted among orthopaedic surgeons and specialist physiotherapists. Participants rated each measurement on a nine-point Likert scale (‘not important’ to ‘critically important’). A consensus meeting was held to finalize the CMS.Aims
Methods
Aims. Hip displacement, common in patients with cerebral palsy (CP), causes pain and hinders adequate care. Hip reconstructive surgery (HRS) is performed to treat hip displacement; however, only a few studies have quantitatively assessed femoral head sphericity after HRS. The aim of this study was to quantitatively assess improvement in hip sphericity after HRS in patients with CP. Methods. We retrospectively analyzed hip radiographs of patients who had undergone HRS because of CP-associated hip displacement. The pre- and postoperative migration percentage (MP), femoral neck-shaft angle (NSA), and sphericity, as determined by the Mose hip ratio (MHR), age at surgery, Gross Motor Function Classification System level, surgical history including Dega pelvic osteotomy, and triradiate cartilage status were studied. Regression analyses using linear mixed model were performed to identify factors affecting hip sphericity improvement. Results. A total of 108 patients were enrolled. The mean preoperative MP was 58.3% (SD 31.7%), which improved to 9.1% (SD 15.6%) at the last follow-up. NSA and MHR improved from 156.5° (SD 11.5°) and 82.3% (SD 8.6%) to 126.0° (SD 18.5°) and 89.1% (SD 9.0%), respectively. Factors affecting the postoperative MHR were preoperative MP (p = 0.005), immediate postoperative MP (p = 0.032), and history of Dega osteotomy (p = 0.046). Conclusion. We found that hip sphericity improves with HRS. Preoperative MP, reduction quality, and
Aims. Guided growth has been used to treat coxa valga for cerebral palsy (CP) children. However, there has been no study on the optimal position of screw application. In this paper we have investigated the influence of screw position on the outcomes of guided growth. Methods. We retrospectively analyzed 61 hips in 32 CP children who underwent proximal femoral hemi epiphysiodesis between July 2012 and September 2017. The hips were divided into two groups according to the transphyseal position of the screw in the coronal plane: across medial quarter (Group 1) or middle quarter (Group 2) of the medial half of the physis. We compared pre- and postoperative radiographs in head-shaft angle (HSA), Reimer’s migration percentage (MP),
A national screening programme has existed in the UK for the diagnosis of developmental dysplasia of the hip (DDH) since 1969. However, every aspect of screening and treatment remains controversial. Screening programmes throughout the world vary enormously, and in the UK there is significant variation in screening practice and treatment pathways. We report the results of an attempt by the British Society for Children’s Orthopaedic Surgery (BSCOS) to identify a nationwide consensus for the management of DDH in order to unify treatment and suggest an approach for screening. A Delphi consensus study was performed among the membership of BSCOS. Statements were generated by a steering group regarding aspects of the management of DDH in children aged under three months, namely screening and surveillance (15 questions), the technique of ultrasound scanning (eight questions), the initiation of treatment (19 questions), care during treatment with a splint (ten questions), and on quality, governance, and research (eight questions). A two-round Delphi process was used and a consensus document was produced at the final meeting of the steering group.Aims
Methods
Developmental dysplasia of the hip (DDH) can be managed effectively with non-surgical interventions when diagnosed early. However, the likelihood of surgical intervention increases with a late presentation. Therefore, an effective screening programme is essential to prevent late diagnosis and reduce surgical morbidity in the population. We conducted a systematic review and meta-analysis of the epidemiological literature from the last 25 years in the UK. Articles were selected from databases searches using MEDLINE, EMBASE, OVID, and Cochrane; 13 papers met the inclusion criteria.Aims
Methods
Children with spinal dysraphism can develop various musculoskeletal deformities, necessitating a range of orthopaedic interventions, causing significant morbidity, and making considerable demands on resources. This systematic review aimed to identify what outcome measures have been reported in the literature for children with spinal dysraphism who undergo orthopaedic interventions involving the lower limbs. A PROSPERO-registered systematic literature review was performed following PRISMA guidelines. All relevant studies published until January 2023 were identified. Individual outcomes and outcome measurement tools were extracted verbatim. The measurement tools were assessed for reliability and validity, and all outcomes were grouped according to the Outcome Measures Recommended for use in Randomized Clinical Trials (OMERACT) filters.Aims
Methods