Advertisement for orthosearch.org.uk
Results 1 - 26 of 26
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1165 - 1175
1 Oct 2024
Frost Teilmann J Petersen ET Thillemann TM Hemmingsen CK Olsen Kipp J Falstie-Jensen T Stilling M

Aims

The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA).

Methods

Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 1000 - 1006
1 Sep 2023
Macken AA Haagmans-Suman A Spekenbrink-Spooren A van Noort A van den Bekerom MPJ Eygendaal D Buijze GA

Aims

The current evidence comparing the two most common approaches for reverse total shoulder arthroplasty (rTSA), the deltopectoral and anterosuperior approach, is limited. This study aims to compare the rate of loosening, instability, and implant survival between the two approaches for rTSA using data from the Dutch National Arthroplasty Registry with a minimum follow-up of five years.

Methods

All patients in the registry who underwent a primary rTSA between January 2014 and December 2016 using an anterosuperior or deltopectoral approach were included, with a minimum follow-up of five years. Cox and logistic regression models were used to assess the association between the approach and the implant survival, instability, and glenoid loosening, independent of confounders.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 174 - 181
1 Feb 2024
Mandalia KP Brodeur PG Li LT Ives K Cruz Jr. AI Shah SS

Aims

The aim of this study was to characterize the influence of social deprivation on the rate of complications, readmissions, and revisions following primary total shoulder arthroplasty (TSA), using the Social Deprivation Index (SDI). The SDI is a composite measurement, in percentages, of seven demographic characteristics: living in poverty, with < 12 years of education, single-parent households, living in rented or overcrowded housing, households without a car, and unemployed adults aged < 65 years.

Methods

Patients aged ≥ 40 years, who underwent primary TSA between 2011 and 2017, were identified using International Classification of Diseases (ICD)-9 Clinical Modification and ICD-10 procedure codes for TSA in the New York Statewide Planning and Research Cooperative System database. Readmission, reoperation, and other complications were analyzed using multivariable Cox proportional hazards regression controlling for SDI, age, ethnicity, insurance status, and Charlson Comorbidity Index.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims

This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA).

Methods

From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery.


Bone & Joint Open
Vol. 4, Issue 2 | Pages 110 - 119
21 Feb 2023
Macken AA Prkić A van Oost I Spekenbrink-Spooren A The B Eygendaal D

Aims

The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry.

Methods

All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims

Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE.

Methods

This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 123 - 130
1 Jan 2021
Lapner P Pollock JW Laneuville O Uhthoff HK Zhang T Sheikh A McIlquham K Trudel G

Aims

Despite recent advances in arthroscopic rotator cuff repair, re-tear rates remain high. New methods to improve healing rates following rotator cuff repair must be sought. Our primary objective was to determine if adjunctive bone marrow stimulation with channelling five to seven days prior to arthroscopic cuff repair would lead to higher Western Ontario Rotator Cuff (WORC) scores at 24 months postoperatively compared with no channelling.

Methods

A prospective, randomized controlled trial was conducted in patients undergoing arthroscopic rotator cuff repair. Patients were randomized to receive either a percutaneous bone channelling of the rotator cuff footprint or a sham procedure under ultrasound guidance five to seven days prior to index surgery. Outcome measures included the WORC, American Shoulder and Elbow Surgeons (ASES), and Constant scores, strength, ultrasound-determined healing rates, and adverse events.


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1620 - 1628
1 Dec 2020
Klug A Nagy A Gramlich Y Hoffmann R

Aims

To evaluate the outcomes of terrible triad injuries (TTIs) in mid-term follow-up and determine whether surgical treatment of the radial head influences clinical and radiological outcomes.

Methods

Follow-up assessment of 88 patients with TTI (48 women, 40 men; mean age 57 years (18 to 82)) was performed after a mean of 4.5 years (2.0 to 9.4). The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder and Hand (DASH) score were evaluated. Radiographs of all patients were analyzed. Fracture types included 13 Mason type I, 16 type II, and 59 type III. Surgical treatment consisted of open reduction and internal fixation (ORIF) in all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) was performed if reconstruction was not possible.


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1549 - 1554
1 Nov 2020
Schwartz AM Farley KX Boden SH Wilson JM Daly CA Gottschalk MB Wagner ER

Aims

The impact of tobacco use on readmission and medical and surgical complications has been documented in hip and knee arthroplasty. However, there remains little information about the effect of smoking on the outcome after total shoulder arthroplasty (TSA). We hypothesized that active smokers are at an increased risk of poor medical and surgial outcomes after TSA.

Methods

Data for patients who underwent arthroplasty of the shoulder in the USA between January 2011 and December 2015 were obtained from the National Readmission Database, and 90-day readmissions and complications were documented using validated coding methods. Multivariate regression analysis was performed to quantify the risk of smoking on the outcome after TSA, while controlling for patient demographics, comorbidities, and hospital-level confounding factors.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 881 - 889
1 Jul 2020
Frank FA Niehaus R Borbas P Eid K

Aims

Conservative treatment of moderately displaced proximal humeral head fractures yields good clinical results, but secondary fragment displacement may occur. Identification of those fractures at risk of displacement may influence initial decision-making.

Methods

A total of 163 shoulders in 162 patients with conservatively treated isolated proximal humeral fractures were included. The fractures occurred between January 2015 and May 2018. The mean age of the patients was 69 years (26 to 100) and the mean follow-up was 144 days (42 to 779). The fractures were classified according to Neer. Scores for osteoporosis (Tingart, Deltoid Tuberosity Index (DTI)) and osteoarthritis (OA) of the glenohumeral joint were assessed. Translation of the head on follow-up radiographs of more than 10 mm was defined as displacement. Eccentric head index (EHI) describes the offset of the humeral head centre in relation to the diaphyseal axis. The ratio was estimated on anteroposterior (AP) and Neer views. Medial hinge was considered intact if the medial cortex proximal and distal to the fracture was in line on AP view.


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 606 - 610
1 May 2020
Nicholson JA Slader B Martindale A Mckie S Robinson CM

Aims

The primary aim of this study was to evaluate the efficacy of distension arthrography in the treatment of adhesive capsulitis of the shoulder. The secondary aim was to assess which patient and procedural factors predicted the recurrence of symptoms after the procedure.

Methods

All patients referred to our shoulder clinic over a ten-year period, between 2008 and 2018, with a clinical diagnosis of capsulitis and symptoms persisting for more than six months, were offered treatment with a distension arthrogram. All procedures were performed by one of five musculoskeletal radiologists, with a combination of steroid, local anaesthetic, and a distention volume of 10 ml, 30 ml, or 50 ml. Patient demographics, procedural details, recurrence of symptoms, and the need for further intervention were evaluated.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 232 - 238
1 Feb 2020
Javed S Hadi S Imam MA Gerogiannis D Foden P Monga P

Aims

Accurate measurement of the glenoid version is important in performing total shoulder arthroplasty (TSA). Our aim was to evaluate the Ellipse method, which involves formally defining the vertical mid-point of the glenoid prior to measuring the glenoid version and comparing it with the ‘classic’ Friedman method.

Methods

This was a retrospective study which evaluated 100 CT scans for patients who underwent a primary TSA. The glenoid version was measured using the Friedman and Ellipse methods by two senior observers. Statistical analyses were performed using the paired t-test for significance and the Bland-Altman plot for agreement.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1512 - 1519
1 Dec 2019
Klug A Konrad F Gramlich Y Hoffmann R Schmidt-Horlohé K

Aims

The aim of this study was to evaluate the outcome of Monteggia-like lesions at midterm follow-up and to determine whether the surgical treatment of the radial head influences the clinical and radiological results.

Patients and Methods

A total of 78 patients with a Monteggia-like lesion, including 44 women and 34 men with a mean age of 54.7 years (19 to 80), were available for assessment after a mean 4.6 years (2 to 9.2). The outcome was assessed using the Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), Mayo Modified Wrist Score (MMWS), and The Disabilities of the Arm, Shoulder and Hand (DASH) score. Radiographs were analyzed for all patients. A total of 12 Mason type I, 16 type II, and 36 type III fractures were included. Surgical treatment consisted of screw fixation for all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) or excision was performed if reconstruction was not possible.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 610 - 614
1 May 2019
Aibinder WR Bartels DW Sperling JW Sanchez-Sotelo J

Aims

Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA).

Patients and Methods

A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m2 (17.3 to 66.4).


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 63 - 67
1 Jan 2019
Erickson BJ Ling D Wong A Eno JJ Dines JS Dines DM Gulotta LV

Aims

The number of rotator cuff repairs that are undertaken is increasing. Reverse shoulder arthroplasty (RSA) is the procedure of choice for patients with rotator cuff arthropathy. We sought to determine whether patients who underwent rotator cuff repair and subsequent RSA had different outcomes compared with a matched control group who underwent RSA without a previous rotator cuff repair.

Patients and Methods

All patients with a history of rotator cuff repair who underwent RSA between 2000 and 2015 with a minimum follow-up of two years were eligible for inclusion as the study group. Outcomes, including the American Shoulder and Elbow Surgeons (ASES) scores, were compared with a matched control group of patients who underwent RSA without having previously undergone rotator cuff repair.


Bone & Joint Research
Vol. 6, Issue 10 | Pages 584 - 589
1 Oct 2017
den Teuling J Pauwels B Janssen L Wyers C Janzing HMJ van den Bergh J Morrenhof JW

Objectives

The goal of this study is to investigate the relation between indicators of osteoporosis (i.e., bone mineral density (BMD), and Cortical Index (CI)) and the complexity of a fracture of the proximal humerus as a result of a low-energy trauma.

Methods

A retrospective chart review of 168 patients (mean age 67.2 years, range 51 to 88.7) with a fracture of the proximal humerus between 2007 and 2011, whose BMD was assessed at the Fracture Liaison Service with Dual Energy X-ray Absorptiometry (DXA) measurements of the hip, femoral neck (FN) and/or lumbar spine (LS), and whose CI and complexity of fracture were assessed on plain anteroposterior radiographs of the proximal humerus.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1190 - 1196
1 Sep 2017
Swarup I Henn CM Nguyen JT Dines DM Craig EV Warren RF Gulotta LV Henn III RF

Aims

Few studies have evaluated the relationship between patients’ pre-operative expectations and the outcome of orthopaedic procedures. Our aim was to determine the effect of expectations on the outcome after primary anatomical total shoulder arthroplasty (TSA). We hypothesised that patients with greater expectations would have better outcomes.

Patients and Methods

Patients undergoing primary anatomical TSA completed the Hospital for Special Surgery’s Shoulder Expectations Survey pre-operatively. The American Shoulder and Elbow Surgeons (ASES), Shoulder Activity Scale (SAS), Short-Form-36 (SF-36), and visual analogue scale (VAS) for pain, fatigue, and general health scores were also collected pre-operatively and two years post-operatively. Pearson correlations were used to assess the relationship between the number of expectations and the outcomes. Differences in outcomes between those with higher and lower levels of expectations for each expectation were assessed by independent samples t-test. Multivariable linear regression analysis was used to control for potential confounding factors.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 818 - 823
1 Jun 2017
Kodama A Mizuseki T Adachi N

Aims

We assessed the long-term (more than ten-year) outcomes of the Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis (RA).

Materials and Methods

We reviewed 41 elbows (Larsen Grade IV, n = 21; Grade V, n = 20) in 31 patients with RA who had undergone a Kudo type-5 total elbow arthroplasty (TEA) between 1994 and 2003, and had been followed up for more than ten years. The humeral component was cementless and the all-polyethylene ulnar component cemented in every patient. Clinical outcome was assessed using the Mayo elbow performance score. We calculated the revision rate and evaluated potential risk factors for revision. The duration of follow-up was a mean 141 months (120 to 203).


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1086 - 1092
1 Aug 2016
de Vos MJ Wagener ML Hannink G van der Pluijm M Verdonschot N Eygendaal D

Aims

Revision total elbow arthroplasty (TEA) is often challenging. The aim of this study was to report on the clinical and radiological results of revision arthroplasty of the elbow with the Latitude TEA.

Patients and Methods

Between 2006 and 2010 we used the Latitude TEA for revision in 18 consecutive elbows (17 patients); mean age 53 years (28 to 80); 14 women. A Kudo TEA was revised in 15 elbows and a Souter-Strathclyde TEA in three.

Stability, range of movement (ROM), visual analogue score (VAS) for pain and functional scores, Elbow Functional Assessment Scale (EFAS), the Functional Rating Index of Broberg and Morrey (FRIBM) and the Modified Andrews’ Elbow Scoring System (MAESS) were assessed pre-operatively and at each post-operative follow-up visit (six, 12 months and biennially thereafter). Radiographs were analysed for loosening, fractures and dislocation. The mean follow-up was 59 months (26 to 89).


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1389 - 1394
1 Oct 2016
Butt U Rashid MS Temperley D Crank S Birch A Freemont AJ Trail IA

Aims

The aim of this study was to analyse human muscle tissue before and after rotator cuff repair to look for evidence of regeneration, and to characterise the changes seen in the type of muscle fibre.

Patients and Methods

Patients were assessed pre-operatively and one year post-operatively using the Oxford Shoulder Score (OSS) and MRI. The cross-sectional area and distribution of the type of muscle fibre were assessed on biopsies, which were taken at surgery and one year post-operatively. Paired samples from eight patients were analysed. There were three men and five women with a mean age of 63 years (50 to 73).


Bone & Joint Research
Vol. 5, Issue 10 | Pages 453 - 460
1 Oct 2016
Ernstbrunner L Werthel J Hatta T Thoreson AR Resch H An K Moroder P

Objectives

The bony shoulder stability ratio (BSSR) allows for quantification of the bony stabilisers in vivo. We aimed to biomechanically validate the BSSR, determine whether joint incongruence affects the stability ratio (SR) of a shoulder model, and determine the correct parameters (glenoid concavity versus humeral head radius) for calculation of the BSSR in vivo.

Methods

Four polyethylene balls (radii: 19.1 mm to 38.1 mm) were used to mould four fitting sockets in four different depths (3.2 mm to 19.1mm). The SR was measured in biomechanical congruent and incongruent experimental series. The experimental SR of a congruent system was compared with the calculated SR based on the BSSR approach. Differences in SR between congruent and incongruent experimental conditions were quantified. Finally, the experimental SR was compared with either calculated SR based on the socket concavity or plastic ball radius.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 818 - 824
1 Jun 2016
Mollon B Mahure SA Ding DY Zuckerman JD Kwon YW

Aims

Depression can significantly affect quality of life and is associated with higher rates of medical comorbidities and increased mortality following surgery. Although depression has been linked to poorer outcomes following orthopaedic trauma, total joint arthroplasty and spinal surgery, we wished to examine the impact of depression in elective total shoulder arthroplasty (TSA) as this has not been previously explored.

Patients and Methods

The United States Nationwide Inpatient Sample (NIS) was used to identify patients undergoing elective TSA over a ten-year period. Between 2002 and 2012, 224 060 patients underwent elective TSA.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 681 - 688
1 May 2015
Wagener ML de Vos MJ Hannink G van der Pluijm M Verdonschot N Eygendaal D

Unlinked, linked and convertible total elbow arthroplasties (TEAs) are currently available. This study is the first to report the clinical results of the convertible Latitude TEA. This was a retrospective study of a consecutive cohort of 63 patients (69 primary TEAs) with a mean age of 60 years (23 to 87). Between 2006 and 2008 a total of 19 men and 50 women underwent surgery. The mean follow-up was 43 months (8 to 84). The range of movement, function and pain all improved six months post-operatively and either continued to improve slightly or reached a plateau thereafter. The complication rate is similar to that reported for other TEA systems. No loosening was seen. Remarkable is the disengagement of the radial head component in 13 TEAs (31%) with a radial head component implanted.

Implantation of both the linked and the unlinked versions of the Latitude TEA results in improvement of function and decreased pain, and shows high patient satisfaction at mid-term follow-up.

Cite this article: Bone Joint J 2015; 97-B:681–8.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1106 - 1113
1 Aug 2013
Lädermann A Walch G Denard PJ Collin P Sirveaux F Favard L Edwards TB Kherad O Boileau P

The indications for reverse shoulder arthroplasty (RSA) continue to be expanded. Associated impairment of the deltoid muscle has been considered a contraindication to its use, as function of the RSA depends on the deltoid and impairment of the deltoid may increase the risk of dislocation. The aim of this retrospective study was to determine the functional outcome and risk of dislocation following the use of an RSA in patients with impaired deltoid function. Between 1999 and 2010, 49 patients (49 shoulders) with impairment of the deltoid underwent RSA and were reviewed at a mean of 38 months (12 to 142) post-operatively. There were nine post-operative complications (18%), including two dislocations. The mean forward elevation improved from 50° (sd 38; 0° to 150°) pre-operatively to 121° (sd 40; 0° to 170°) at final follow-up (p < 0.001). The mean Constant score improved from 24 (sd 12; 2 to 51) to 58 (sd 17; 16 to 83) (p < 0.001). The mean Single Assessment Numeric Evaluation score was 71 (sd 17; 10 to 95) and the rate of patient satisfaction was 98% (48 of 49) at final follow-up.

These results suggest that pre-operative deltoid impairment, in certain circumstances, is not an absolute contraindication to RSA. This form of treatment can yield reliable improvement in function without excessive risk of post-operative dislocation.

Cite this article: Bone Joint J 2013;95-B:1106–13.


Bone & Joint Research
Vol. 3, Issue 4 | Pages 117 - 122
1 Apr 2014
Uhthoff HK Coletta E Trudel G

Objectives

Although many clinical and experimental investigations have shed light on muscle atrophy and intramuscular accumulation of fat after rotator cuff disruption, none have reported on their onset in the absence of muscle retraction.

Methods

In 30 rabbits, we detached one supraspinatus (SSP) tendon and repaired it immediately, thus preventing muscle retraction. The animals were killed in groups of 10 at one, two and six weeks. Both shoulders of 15 non-operated rabbits served as controls. We measured the weight and volume of SSP muscles and quantified the cross-sectional area of intramuscular fat (i-fat) histologically.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 82 - 87
1 Jan 2014
Duquin TR Jacobson JA Schleck CD Larson DR Sanchez-Sotelo J Morrey BF

Treatment of an infected total elbow replacement (TER) is often successful in eradicating or suppressing the infection. However, the extensor mechanism may be compromised by both the infection and the surgery. The goal of this study was to assess triceps function in patients treated for deep infection complicating a TER. Between 1976 and 2007 a total of 217 TERs in 207 patients were treated for infection of a TER at our institution. Superficial infections and those that underwent resection arthroplasty were excluded, leaving 93 TERs. Triceps function was assessed by examination and a questionnaire. Outcome was measured using the Mayo Elbow Performance Score (MEPS).

Triceps weakness was identified in 51 TERs (49 patients, 55%). At a mean follow-up of five years (0.8 to 34), the extensor mechanism was intact in 13 patients, with the remaining 38 having bone or soft-tissue loss. The mean MEPS was 70 points (5 to 100), with a mean functional score of 18 (0 to 25) of a possible 25 points.

Infection following TER can often be eradicated; however, triceps weakness occurs in more than half of the patients and may represent a major functional problem.

Cite this article: Bone Joint J 2014;96-B:82–7.