Advertisement for orthosearch.org.uk
Results 1 - 31 of 31
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 815 - 818
1 Aug 2001
Alonso JA Shaw DL Maxwell A McGill GP Hart GC

We measured the scattered radiation received by theatre staff, using high-sensitivity electronic personal dosimeters, during fixation of extracapsular fractures of the neck of the femur by dynamic hip screw. The dose received was correlated with that received by the patient, and the distance from the source of radiation. A scintillation detector and a water-filled model were used to define a map of the dose rate of scattered radiation in a standard operating theatre during surgery. Beyond two metres from the source of radiation, the scattered dose received was consistently low, while within the operating distance that received by staff was significant for both lateral and posteroanterior (PA) projections. The routine use of lead aprons outside the 2 m zone may be unnecessary. Within that zone it is recommended that lead aprons be worn and that thyroid shields are available for the surgeon and nursing assistants


Aims. Ankle fracture fixation is commonly performed by junior trainees. Simulation training using cadavers may shorten the learning curve and result in a technically superior surgical performance. Methods. We undertook a preliminary, pragmatic, single-blinded, multicentre, randomized controlled trial of cadaveric simulation versus standard training. Primary outcome was fracture reduction on postoperative radiographs. Results. Overall, 139 ankle fractures were fixed by 28 postgraduate year three to five trainee surgeons (mean age 29.4 years; 71% males) during ten months' follow-up. Under the intention-to-treat principle, a technically superior fixation was performed by the cadaveric-trained group compared to the standard-trained group, as measured on the first postoperative radiograph against predefined acceptability thresholds. The cadaveric-trained group used a lower intraoperative dose of radiation than the standard-trained group (mean difference 0.011 Gym. 2. , 95% confidence interval 0.003 to 0.019; p = 0.009). There was no difference in procedure time. Conclusion. Trainees randomized to cadaveric training performed better ankle fracture fixations and irradiated patients less during surgery compared to standard-trained trainees. This effect, which was previously unknown, is likely to be a consequence of the intervention. Further study is required. Cite this article: Bone Jt Open 2023;4(8):594–601


Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. Methods. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty). Results. Eight female (29%) and 20 male trainees (71%), mean age 29.4 years, performed 317 DHS operations and 243 hemiarthroplasties during ten months of follow-up. Primary analysis was a random effect model with surgeon-level fixed effects of patient condition, patient age, and surgeon experience, with a random intercept for surgeon. Under the intention-to-treat principle, for hemiarthroplasty there was better implant position in favour of cadaveric training, measured by leg length discrepancy ≤ 10 mm (odds ratio (OR) 4.08 (95% confidence interval (CI) 1.17 to 14.22); p = 0.027). There were significantly fewer postoperative blood transfusions required in patients undergoing hemiarthroplasty by cadaveric-trained compared to standard-trained surgeons (OR 6.00 (95% CI 1.83 to 19.69); p = 0.003). For DHS, there was no significant between-group difference in implant position as measured by tip-apex distance ≤ 25 mm (OR 6.47 (95% CI 0.97 to 43.05); p = 0.053). No between-group differences were observed for any secondary clinical outcomes. Conclusion. Trainees randomized to additional cadaveric training performed hip fracture fixation with better implant positioning and fewer postoperative blood transfusions in hemiarthroplasty. This effect, which was previously unknown, may be a consequence of the intervention. Further study is required. Cite this article: Bone Jt Open 2023;4(8):602–611


Bone & Joint Open
Vol. 5, Issue 2 | Pages 117 - 122
9 Feb 2024
Chaturvedi A Russell H Farrugia M Roger M Putti A Jenkins PJ Feltbower S

Aims. Occult (clinical) injuries represent 15% of all scaphoid fractures, posing significant challenges to the clinician. MRI has been suggested as the gold standard for diagnosis, but remains expensive, time-consuming, and is in high demand. Conventional management with immobilization and serial radiography typically results in multiple follow-up attendances to clinic, radiation exposure, and delays return to work. Suboptimal management can result in significant disability and, frequently, litigation. Methods. We present a service evaluation report following the introduction of a quality-improvement themed, streamlined, clinical scaphoid pathway. Patients are offered a removable wrist splint with verbal and written instructions to remove it two weeks following injury, for self-assessment. The persistence of pain is the patient’s guide to ‘opt-in’ and to self-refer for a follow-up appointment with a senior emergency physician. On confirmation of ongoing signs of clinical scaphoid injury, an urgent outpatient ‘fast’-wrist protocol MRI scan is ordered, with instructions to maintain wrist immobilization. Patients with positive scan results are referred for specialist orthopaedic assessment via a virtual fracture clinic. Results. From February 2018 to January 2019, there were 442 patients diagnosed as clinical scaphoid fractures. 122 patients (28%) self-referred back to the emergency department at two weeks. Following clinical review, 53 patients were discharged; MRI was booked for 69 patients (16%). Overall, six patients (< 2% of total; 10% of those scanned) had positive scans for a scaphoid fracture. There were no known missed fractures, long-term non-unions or malunions resulting from this pathway. Costs were saved by avoiding face-to-face clinical review and MRI scanning. Conclusion. A patient-focused opt-in approach is safe and effective to managing the suspected occult (clinical) scaphoid fracture. Cite this article: Bone Jt Open 2024;5(2):117–122


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 696 - 702
1 May 2016
Theologis AA Burch S Pekmezci M

Aims. We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy. Materials and Methods. Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers. Results. There were no neuroforaminal breaches in either group. The set-up time for the O-Arm was significantly longer than for the C-Arm, while total time for placement of the screws was significantly shorter for the O-Arm than for the C-Arm (p = 0.001). The mean absorbed radiation dose during fluoroscopy was 1063 mRad (432.5 mRad to 4150 mRad). No radiation was detected on the surgeon during fluoroscopy, or when he left the room during the use of the O-Arm. The mean radiation detected on the cadavers was significantly higher in the O-Arm group (2710 mRem standard deviation (. sd. ) 1922) than during fluoroscopy (11.9 mRem . sd 14.8). (p < 0.01). Conclusion. O-Arm/Stealth Navigation allows for faster percutaneous placement of iliosacral screws in a radiation-free environment for surgeons, albeit with the same accuracy and significantly more radiation exposure to cadavers, when compared with standard fluoroscopy. Take home message: Placement of iliosacral screws with O-Arm/Stealth Navigation can be performed safely and effectively. Cite this article: Bone Joint J 2016;98-B:696–702


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1668 - 1673
1 Dec 2016
Konda SR Goch AM Leucht P Christiano A Gyftopoulos S Yoeli G Egol KA

Aims. To evaluate whether an ultra-low-dose CT protocol can diagnose selected limb fractures as well as conventional CT (C-CT). Patients and Methods. We prospectively studied 40 consecutive patients with a limb fracture in whom a CT scan was indicated. These were scanned using an ultra-low-dose CT Reduced Effective Dose Using Computed Tomography In Orthopaedic Injury (REDUCTION) protocol. Studies from 16 selected cases were compared with 16 C-CT scans matched for age, gender and type of fracture. Studies were assessed for diagnosis and image quality. Descriptive and reliability statistics were calculated. The total effective radiation dose for each scanned site was compared. Results. The mean estimated effective dose (ED) for the REDUCTION protocol was 0.03 milliSieverts (mSv) and 0.43 mSv (p < 0.005) for C-CT. The sensitivity (Sn), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV) of the REDUCTION protocol to detect fractures were 0.98, 0.89, 0.98 and 0.89 respectively when two occult fractures were excluded. Inter- and intra-observer reliability for diagnosis using the REDUCTION protocol (κ = 0.75, κ = 0.71) were similar to those of C-CT (κ = 0.85, κ = 0.82). Using the REDUCTION protocol, 3D CT reconstructions were equivalent in quality and diagnostic information to those generated by C-CT (κ = 0.87, κ = 0.94). Conclusion. With a near 14-fold reduction in estimated ED compared with C-CT, the REDUCTION protocol reduces the amount of CT radiation substantially without significant diagnostic decay. It produces images that appear to be comparable with those of C-CT for evaluating fractures of the limbs. Cite this article: Bone Joint J 2016;98-B:1668-73


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 984 - 988
1 Jul 2010
Guo JJ Tang N Yang HL Tang TS

We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study. A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients’ age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware. We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p < 0.001, and 97.9 vs 81.2 minutes, p < 0.001, respectively). After one year, all the fractures had united. Patients who had intramedullary nailing had a higher mean pain score, but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed. We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with these fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1073 - 1078
1 Aug 2008
Little NJ Verma V Fernando C Elliott DS Khaleel A

We compared the outcome of patients treated for an intertrochanteric fracture of the femoral neck with a locked, long intramedullary nail with those treated with a dynamic hip screw (DHS) in a prospective randomised study. Each patient who presented with an extra-capsular hip fracture was randomised to operative stabilisation with either a long intramedullary Holland nail or a DHS. We treated 92 patients with a Holland nail and 98 with a DHS. Pre-operative variables included the Mini Mental test score, patient mobility, fracture pattern and American Society of Anesthesiologists grading. Peri-operative variables were anaesthetic time, operating time, radiation time and blood loss. Post-operative variables were time to mobilising with a frame, wound infection, time to discharge, time to fracture union, and mortality. We found no significant difference in the pre-operative variables. The mean anaesthetic and operation times were shorter in the DHS group than in the Holland nail group (29.7 vs 40.4 minutes, p < 0.001; and 40.3 vs 54 minutes, p < 0.001, respectively). There was an increased mean blood loss within the DHS group versus the Holland nail group (160 ml vs 78 ml, respectively, p < 0.001). The mean time to mobilisation with a frame was shorter in the Holland nail group (DHS 4.3 days, Holland nail 3.6 days, p = 0.012). More patients needed a post-operative blood transfusion in the DHS group (23 vs seven, p = 0.003) and the mean radiation time was shorter in this group (DHS 0.9 minutes vs Holland nail 1.56 minutes, p < 0.001). The screw of the DHS cut out in two patients, one of whom underwent revision to a Holland nail. There were no revisions in the Holland nail group. All fractures in both groups were united when followed up after one year. We conclude that the DHS can be implanted more quickly and with less exposure to radiation than the Holland nail. However, the resultant blood loss and need for transfusion is greater. The Holland nail allows patients to mobilise faster and to a greater extent. We have therefore adopted the Holland nail as our preferred method of treating intertrochanteric fractures of the hip


Bone & Joint Open
Vol. 5, Issue 2 | Pages 147 - 153
19 Feb 2024
Hazra S Saha N Mallick SK Saraf A Kumar S Ghosh S Chandra M

Aims

Posterior column plating through the single anterior approach reduces the morbidity in acetabular fractures that require stabilization of both the columns. The aim of this study is to assess the effectiveness of posterior column plating through the anterior intrapelvic approach (AIP) in the management of acetabular fractures.

Methods

We retrospectively reviewed the data from R G Kar Medical College, Kolkata, India, from June 2018 to April 2023. Overall, there were 34 acetabulum fractures involving both columns managed by medial buttress plating of posterior column. The posterior column of the acetabular fracture was fixed through the AIP approach with buttress plate on medial surface of posterior column. Mean follow-up was 25 months (13 to 58). Accuracy of reduction and effectiveness of this technique were measured by assessing the Merle d’Aubigné score and Matta’s radiological grading at one year and at latest follow-up.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1256 - 1265
1 Nov 2022
Keene DJ Alsousou J Harrison P O’Connor HM Wagland S Dutton SJ Hulley P Lamb SE Willett K

Aims

To determine whether platelet-rich plasma (PRP) injection improves outcomes two years after acute Achilles tendon rupture.

Methods

A randomized multicentre two-arm parallel-group, participant- and assessor-blinded superiority trial was undertaken. Recruitment commenced on 28 July 2015 and two-year follow-up was completed in 21 October 2019. Participants were 230 adults aged 18 years and over, with acute Achilles tendon rupture managed with non-surgical treatment from 19 UK hospitals. Exclusions were insertion or musculotendinous junction injuries, major leg injury or deformity, diabetes, platelet or haematological disorder, medication with systemic corticosteroids, anticoagulation therapy treatment, and other contraindicating conditions. Participants were randomized via a central online system 1:1 to PRP or placebo injection. The main outcome measure was Achilles Tendon Rupture Score (ATRS) at two years via postal questionnaire. Other outcomes were pain, recovery goal attainment, and quality of life. Analysis was by intention-to-treat.


Bone & Joint Open
Vol. 3, Issue 9 | Pages 726 - 732
16 Sep 2022
Hutchison A Bodger O Whelan R Russell ID Man W Williams P Bebbington A

Aims

We introduced a self-care pathway for minimally displaced distal radius fractures, which involved the patient being discharged from a Virtual Fracture Clinic (VFC) without a physical review and being provided with written instructions on how to remove their own cast or splint at home, plus advice on exercises and return to function.

Methods

All patients managed via this protocol between March and October 2020 were contacted by a medical secretary at a minimum of six months post-injury. The patients were asked to complete the Patient-Rated Wrist Evaluation (PRWE), a satisfaction questionnaire, advise if they had required surgery and/or contacted any health professional, and were also asked for any recommendations on how to improve the service. A review with a hand surgeon was organized if required, and a cost analysis was also conducted.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 259 - 263
1 Mar 1998
Moore KD Goss K Anglen JO

We report a prospective, randomised, blinded clinical comparison of the use of indomethacin or radiation therapy for the prevention of heterotopic ossification (HO) in 75 adults who had open reduction and internal fixation of acetabular fractures through either a Kocher-Langenbeck, a combined ilioinguinal and Kocher-Langenbeck, or an extended iliofemoral approach. Indomethacin, 25 mg, was given three times daily for six weeks. Radiation with 800 cGy was delivered within three days of operation. Plain radiographs were reviewed and given Brooker classification scores by three independent observers who were unaware of the method of prophylaxis. One patient died from unrelated causes and two were lost to follow-up, leaving 72, 33 in the radiation group and 39 in the indomethacin group, available for evaluation at a mean of 12 months (6 to 48). There was no significant difference in the two groups in terms of age, gender, injury severity score, estimated blood loss, delay to surgery, head injury, presence of femoral head dislocation, or operating time, and no complications due to either method of treatment. The final extent of HO was already present by six weeks in all patients who were followed up. Three patients in the radiation group and five who received indomethacin developed HO of Brooker grade III. Two patients in the indomethacin group developed Brooker IV changes; both had failed to receive proper doses of the drug. Cochran-Armitage analysis showed no significant difference between the two treatment groups as regards the formation of HO. Indomethacin and single-dose radiation therapy are both safe and effective for the prevention of HO after operation for acetabular fractures. Radiation therapy is, however, approximately 200 times more expensive than indomethacin therapy at our institution and has other risks


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1229 - 1241
14 Sep 2020
Blom RP Hayat B Al-Dirini RMA Sierevelt I Kerkhoffs GMMJ Goslings JC Jaarsma RL Doornberg JN

Aims

The primary aim of this study was to address the hypothesis that fracture morphology might be more important than posterior malleolar fragment size in rotational type posterior malleolar ankle fractures (PMAFs). The secondary aim was to identify clinically important predictors of outcome for each respective PMAF-type, to challenge the current dogma that surgical decision-making should be based on fragment size.

Methods

This observational prospective cohort study included 70 patients with operatively treated rotational type PMAFs, respectively: 23 Haraguchi Type I (large posterolateral-oblique), 22 Type II (two-part posterolateral and posteromedial), and 25 (avulsion-) Type III. There was no standardized protocol on how to address the PMAFs and CT-imaging was used to classify fracture morphology and quality of postoperative syndesmotic reduction. Quantitative 3D-CT (Q3DCT) was used to assess the quality of fracture reduction, respectively: the proportion of articular involvement; residual intra-articular: gap, step-off, and 3D-displacement; and residual gap and step-off at the fibular notch. These predictors were correlated with the Foot and Ankle Outcome Score (FAOS) at two-years follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 700 - 705
1 Jul 2003
Burd TA Hughes MS Anglen JO

Indomethacin is commonly administered for the prophylaxis of heterotopic ossification (HO) after the surgical treatment of acetabular fractures. Non-steroidal anti-inflammatory drugs such as indomethacin, have been associated with delayed healing of fractures and mechanically weaker callus. Our aim was to determine if patients with an acetabular fracture, who received indomethacin for prophylaxis against HO, were at risk of delayed healing or nonunion of any associated fractures of long bones. We reviewed 282 patients who had had open reduction and internal fixation of an acetabular fracture. Patients at risk of HO were randomised to receive either radiation therapy (XRT) or indomethacin. Of these patients, 112 had sustained at least one concomitant fracture of a long bone; 36 needed no prophylaxis, 38 received focal radiation and 38 received indomethacin. Fifteen patients developed 16 nonunions. When comparing patients who received indomethacin with those who did not, a significant difference was noted in the rate of nonunion (26% v 7%; p = 0.004). Patients with concurrent fractures of the acetabulum and long bones who receive indomethacin have a significantly greater risk of nonunion of the fractures of the long bones when compared with those who receive XRT or no prophylaxis


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 918 - 924
1 Jul 2020
Rosslenbroich SB Heimann K Katthagen JC Koesters C Riesenbeck O Petersen W Raschke MJ Schliemann B

Aims

There is a lack of long-term data for minimally invasive acromioclavicular (AC) joint repair. Furthermore, it is not clear if good early clinical results can be maintained over time. The purpose of this study was to report long-term results of minimally invasive AC joint reconstruction (MINAR) and compare it to corresponding short-term data.

Methods

We assessed patients with a follow-up of at least five years after minimally invasive flip-button repair for high-grade AC joint dislocation. The clinical outcome was evaluated using the Constant score and a questionnaire. Ultrasound determined the coracoclavicular (CC) distance. Results of the current follow-up were compared to the short-term results of the same cohort.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1307 - 1312
1 Oct 2019
Jacxsens M Schmid J Zdravkovic V Jost B Spross C

Aims

In order to determine whether and for whom serial radiological evaluation is necessary in one-part proximal humerus fractures, we set out to describe the clinical history and predictors of secondary displacement in patients sustaining these injuries.

Patients and Methods

Between January 2014 and April 2016, all patients with an isolated, nonoperatively treated one-part proximal humerus fracture were prospectively followed up. Clinical and radiological evaluation took place at less than two, six, 12, and 52 weeks. Fracture configuration, bone quality, and comminution were determined on the initial radiographs. Fracture healing, secondary displacement, and treatment changes were recorded during follow-up.


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1416 - 1422
1 Nov 2019
Rohilla R Sharma PK Wadhwani J Rohilla S Beniwal R Singh R Devgan A

Aims

In this randomized study, we aimed to compare quality of regenerate in monolateral versus circular frame fixation in 30 patients with infected nonunion of tibia.

Patients and Methods

Both groups were comparable in demographic and injury characteristics. A phantom (aluminium step wedge of increasing thickness) was designed to compare the density of regenerate on radiographs. A CT scan was performed at three and six months postoperatively to assess regenerate density. A total of 30 patients (29 male, one female; mean age 32.54 years (18 to 60)) with an infected nonunion of a tibial fracture presenting to our tertiary institute between June 2011 and April 2016 were included in the study.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1300 - 1306
1 Oct 2019
Oliver WM Smith TJ Nicholson JA Molyneux SG White TO Clement ND Duckworth AD

Aims

The primary aim of this study was to develop a reliable, effective radiological score to assess the healing of humeral shaft fractures, the Radiographic Union Score for HUmeral fractures (RUSHU). The secondary aim was to assess whether the six-week RUSHU was predictive of nonunion at six months after the injury.

Patients and Methods

Initially, 20 patients with radiographs six weeks following a humeral shaft fracture were selected at random from a trauma database and scored by three observers, based on the Radiographic Union Scale for Tibial fractures system. After refinement of the RUSHU criteria, a second group of 60 patients with radiographs six weeks after injury, 40 with fractures that united and 20 with fractures that developed nonunion, were scored by two blinded observers.


Bone & Joint Research
Vol. 5, Issue 4 | Pages 116 - 121
1 Apr 2016
Leow JM Clement ND Tawonsawatruk T Simpson CJ Simpson AHRW

Objectives

The radiographic union score for tibial (RUST) fractures was developed by Whelan et al to assess the healing of tibial fractures following intramedullary nailing. In the current study, the repeatability and reliability of the RUST score was evaluated in an independent centre (a) using the original description, (b) after further interpretation of the description of the score, and (c) with the immediate post-operative radiograph available for comparison.

Methods

A total of 15 radiographs of tibial shaft fractures treated by intramedullary nailing (IM) were scored by three observers using the RUST system. Following discussion on how the criteria of the RUST system should be implemented, 45 sets (i.e. AP and lateral) of radiographs of IM nailed tibial fractures were scored by five observers. Finally, these 45 sets of radiographs were rescored with the baseline post-operative radiograph available for comparison.


Bone & Joint Research
Vol. 6, Issue 7 | Pages 423 - 432
1 Jul 2017
van der Stok J Hartholt KA Schoenmakers DAL Arts JJC

Objectives

The aim of this systematic literature review was to assess the clinical level of evidence of commercially available demineralised bone matrix (DBM) products for their use in trauma and orthopaedic related surgery.

Methods

A total of 17 DBM products were used as search terms in two available databases: Embase and PubMed according to the Preferred Reporting Items for Systematic Reviews and Meta Analyses statement. All articles that reported the clinical use of a DBM-product in trauma and orthopaedic related surgery were included.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1126 - 1131
1 Aug 2015
Nortunen S Flinkkilä T Lantto I Kortekangas T Niinimäki J Ohtonen P Pakarinen H

We prospectively assessed the diagnostic accuracy of the gravity stress test and clinical findings to evaluate the stability of the ankle mortise in patients with supination–external rotation-type fractures of the lateral malleolus without widening of the medial clear space. The cohort included 79 patients with a mean age of 44 years (16 to 82). Two surgeons assessed medial tenderness, swelling and ecchymosis and performed the external rotation (ER) stress test (a reference standard). A diagnostic radiographer performed the gravity stress test.

For the gravity stress test, the positive likelihood ratio (LR) was 5.80 with a 95% confidence interval (CI) of 2.75 to 12.27, and the negative LR was 0.15 (95% CI 0.07 to 0.35), suggesting a moderate change from the pre-test probability. Medial tenderness, both alone and in combination with swelling and/or ecchymosis, indicated a small change (positive LR, 2.74 to 3.25; negative LR, 0.38 to 0.47), whereas swelling and ecchymosis indicated only minimal changes (positive LR, 1.41 to 1.65; negative LR, 0.38 to 0.47).

In conclusion, when gravity stress test results are in agreement with clinical findings, the result is likely to predict stability of the ankle mortise with an accuracy equivalent to ER stress test results. When clinical examination suggests a medial-side injury, however, the gravity stress test may give a false negative result.

Cite this article: Bone Joint J 2015; 97-B:1126–31.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1126 - 1131
1 Aug 2016
Shiels SM Cobb RR Bedigrew KM Ritter G Kirk JF Kimbler A Finger Baker I Wenke JC

Aims

Demineralised bone matrix (DBM) is rarely used for the local delivery of prophylactic antibiotics. Our aim, in this study, was to show that a graft with a bioactive glass and DBM combination, which is currently available for clinical use, can be loaded with tobramycin and release levels of antibiotic greater than the minimum inhibitory concentration for Staphylococcus aureus without interfering with the bone healing properties of the graft, thus protecting the graft and surrounding tissues from infection.

Materials and Methods

Antibiotic was loaded into a graft and subsequently evaluated for drug elution kinetics and the inhibition of bacterial growth. A rat femoral condylar plug model was used to determine the effect of the graft, loaded with antibiotic, on bone healing.


Bone & Joint Research
Vol. 5, Issue 5 | Pages 191 - 197
1 May 2016
Kienast B Kowald B Seide K Aljudaibi M Faschingbauer M Juergens C Gille J

Objectives

The monitoring of fracture healing is a complex process. Typically, successive radiographs are performed and an emerging calcification of the fracture area is evaluated. The aim of this study was to investigate whether different bone healing patterns can be distinguished using a telemetric instrumented femoral internal plate fixator.

Materials and Methods

An electronic telemetric system was developed to assess bone healing mechanically. The system consists of a telemetry module which is applied to an internal locking plate fixator, an external reader device, a sensor for measuring externally applied load and a laptop computer with processing software. By correlation between externally applied load and load measured in the implant, the elasticity of the osteosynthesis is calculated. The elasticity decreases with ongoing consolidation of a fracture or nonunion and is an appropriate parameter for the course of bone healing. At our centre, clinical application has been performed in 56 patients suffering nonunion or fracture of the femur.


Bone & Joint Research
Vol. 2, Issue 3 | Pages 51 - 57
1 Mar 2013
Sullivan MP Torres SJ Mehta S Ahn J

Neurogenic heterotopic ossification (NHO) is a disorder of aberrant bone formation affecting one in five patients sustaining a spinal cord injury or traumatic brain injury. Ectopic bone forms around joints in characteristic patterns, causing pain and limiting movement especially around the hip and elbow. Clinical sequelae of neurogenic heterotopic ossification include urinary tract infection, pressure injuries, pneumonia and poor hygiene, making early diagnosis and treatment clinically compelling. However, diagnosis remains difficult with more investigation needed. Our pathophysiological understanding stems from mechanisms of basic bone formation enhanced by evidence of systemic influences from circulating humor factors and perhaps neurological ones. This increasing understanding guides our implementation of current prophylaxis and treatment including the use of non-steroidal anti-inflammatory drugs, bisphosphonates, radiation therapy and surgery and, importantly, should direct future, more effective ones.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 646 - 651
1 May 2014
Mutch J Laflamme GY Hagemeister N Cikes A Rouleau DM

In this study, we describe a morphological classification for greater tuberosity fractures of the proximal humerus. We divided these fractures into three types: avulsion, split and depression. We retrospectively reviewed all shoulder radiographs showing isolated greater tuberosity fractures in a Level I trauma centre between July 2007 and July 2012. We identified 199 cases where records and radiographs were reviewed and included 79 men and 120 women with a mean age of 58 years (23 to 96). The morphological classification was applied to the first 139 cases by three reviewers on two occasions using the Kappa statistic and compared with the AO and Neer classifications. The inter- and intra-observer reliability of the morphological classification was 0.73 to 0.77 and 0.69 to 0.86, respectively. This was superior to the Neer (0.31 to 0.35/0.54 to 0.63) and AO (0.30 to 0.32/0.59 to 0.65) classifications. The distribution of avulsion, split and depression type fractures was 39%, 41%, and 20%, respectively. This classification of greater tuberosity fractures is more reliable than the Neer or AO classifications. These distinct fracture morphologies are likely to have implications in terms of pathophysiology and surgical technique.

Cite this article: Bone Joint J 2014;96-B:646–51.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 446 - 453
1 Apr 2012
Moran CG Forward DP

There have been many advances in the resuscitation and early management of patients with severe injuries during the last decade. These have come about as a result of the reorganisation of civilian trauma services in countries such as Germany, Australia and the United States, where the development of trauma systems has allowed a concentration of expertise and research. The continuing conflicts in the Middle East have also generated a significant increase in expertise in the management of severe injuries, and soldiers now survive injuries that would have been fatal in previous wars. This military experience is being translated into civilian practice.

The aim of this paper is to give orthopaedic surgeons a practical, evidence-based guide to the current management of patients with severe, multiple injuries. It must be emphasised that this depends upon the expertise, experience and facilities available within the local health-care system, and that the proposed guidelines will inevitably have to be adapted to suit the local resources.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 704 - 708
1 May 2012
Mauffrey C McGuinness K Parsons N Achten J Costa ML

The ideal form of fixation for displaced, extra-articular fractures of the distal tibia remains controversial. In the UK, open reduction and internal fixation with locking-plates and intramedullary nailing are the two most common forms of treatment. Both techniques provide reliable fixation but both are associated with specific complications. There is little information regarding the functional recovery following either procedure.

We performed a randomised pilot trial to determine the functional outcome of 24 adult patients treated with either a locking-plate (n = 12) or an intramedullary nailing (n = 12). At six months, there was an adjusted difference of 13 points in the Disability Rating Index in favour of the intramedullary nail. However, this was not statistically significant in this pilot trial (p = 0.498). A total of seven patients required further surgery in the locking-plate group and one in the intramedullary nail group.

This study suggests that there may be clinically relevant, functional differences in patients treated with nail versus locking-plate fixation for fractures of the distal tibia and differences in related complications. Further trials are required to confirm the findings of this pilot investigation.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 72 - 77
1 Jan 2008
Sharma S Fraser M Lovell F Reece A McLellan AR

Osteoporosis and fragility fractures in men constitute a considerable burden in healthcare. We have reviewed 2035 men aged over 50 years with 2142 fractures to clarify the epidemiology of these injuries and their underlying risk factors. The prevalence of osteoporosis ranged between 17.5% in fractures of the ankle and 57.8% in those of the hip. The main risk factors associated with osteoporosis were smoking (47.4%), alcohol excess (36.2%), body mass index < 21 (12.8%) and a family history of osteoporosis (8.4%). Immobility, smoking, self-reported alcohol excess, a low body mass index, age ≥72 and loss in height were significantly more common among men with fractures of the hip than in those with fractures elsewhere.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1495 - 1498
1 Nov 2008
Shen J Tong P Qu H

This randomised study compared outcomes in patients with displaced fractures of the clavicle treated by open reduction and fixation by a reconstruction plate which was placed either superiorly or three-dimensionally. Between 2003 and 2006, 133 consecutive patients with a mean age of 44.2 years (18 to 60) with displaced midshaft fractures of the clavicle were allocated randomly to a three-dimensional (3D) (67 patients) or superior group (66). Outcome measures included the peri-operative outcome index, delayed union, revision surgery and symptoms beyond 16 weeks. CT was used to reconstruct an image of each affected clavicle and Photoshop 7.0 software employed to calculate the percentage of the clavicular cortical area in the sagittal plane. The patients were reviewed clinically and radiographically at four and 12 months after the operation. The superior plate group had a higher rate of delayed union and had more symptomatic patients than the 3D group (p < 0.05). The percentage comparisons of cortical bone area showed that cortical bone in the superior distal segment is thicker than in the inferior segment, it is also thicker in the anterior mid-section than in the posterior (p < 0.05).

If fixation of midshaft fractures of the clavicle with a plate is indicated, a 3D reconstruction plate is better than one placed superiorly, because it is consistent with the stress distribution and shape of the clavicle.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1391 - 1396
1 Oct 2005
Griffin DB Beaulé PE Matta JM

There remains uncertainty about the most effective surgical approach in the treatment of complex fractures of the acetabulum. We have reviewed the experience of a single surgeon using the extended iliofemoral approach, as described by Letournel.

A review of the database of such fractures identified 106 patients operated on using this approach with a minimum follow-up of two years. All data were collected prospectively. The fractures involved both columns in 64 (60%). Operation was undertaken in less than 21 days after injury in 71 patients (67%) and in 35 (33%) the procedure was carried out later than this. The reduction of the fracture was measured on plain radiographs taken after operation and defined as anatomical (0 to 1 mm of displacement); imperfect (2 to 3 mm) or poor (> 3 mm). The functional outcome was measured by the modified Merle d’Aubigné and Postel score. The mean follow-up was for 6.3 years (2 to 17).

All patients achieved union of the fractures. The reduction was graded as anatomical in 76 (72%) of the patients, imperfect in 23 (22%), and poor in six (6%). The mean Merle d’Aubigné and Postel score was 15 (5 to 18) with 68 patients (64%) showing good or excellent and 38 (36%) fair or poor results. Function correlated significantly with the accuracy of the reduction (p < 0.009). Significant heterotopic ossification developed in 32 patients (30%) and was associated with a worse mean Merle d’Aubigné and Postel score of 13.7.

The extended iliofemoral approach can be performed safely in selected complex acetabular fractures with an acceptable clinical outcome and rate of complications. Effective prophylaxis against heterotopic ossification should be strongly considered.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 367 - 373
1 Mar 2005
Heetveld MJ Raaymakers ELFB van Eck-Smit BL van Walsum ADP Luitse JSK

The results of meta-analysis show a revision rate of 33% for internal fixation of displaced fractures of the femoral neck, mostly because of nonunion. Osteopenia and osteoporosis are highly prevalent in elderly patients. Bone density has been shown to correlate with the intrinsic stability of the fixation of the fracture in cadaver and retrospective studies. We aimed to confirm or refute this finding in a clinical setting.

We performed a prospective, multicentre study of 111 active patients over 60 years of age with a displaced fracture of the femoral neck which was eligible for internal fixation. The bone density of the femoral neck was measured pre-operatively by dual-energy x-ray absorptiometry (DEXA). The patients were divided into two groups namely, those with osteopenia (66%, mean T-score −1.6) and those with osteoporosis (34%, mean T-score −3.0). Age (p = 0.47), gender (p = 0.67), delay to surgery (p = 0.07), the angle of the fracture (p = 0.33) and the type of implant (p = 0.48) were similar in both groups.

Revision to arthroplasty was performed in 41% of osteopenic and 42% of osteoporotic patients (p = 0.87). Morbidity (p = 0.60) and mortality were similar in both groups (p = 0.65). Our findings show that the clinical outcome of internal fixation for displaced fractures of the femoral neck does not depend on bone density and that pre-operative DEXA is not useful.