Advertisement for orthosearch.org.uk
Results 1 - 50 of 321
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 765 - 766
1 Jul 2022
Haddad FS Malchau H


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 469 - 476
1 Apr 2010
Shimmin AJ Walter WL Esposito C

The survivorship of contemporary resurfacing arthroplasty of the hip using metal-on-metal bearings is better than that of first generation designs, but short-term failures still occur. The most common reasons for failure are fracture of the femoral neck, loosening of the component, osteonecrosis of the femoral head, reaction to metal debris and malpositioning of the component. In 2008 the Australian National Joint Registry reported an inverse relationship between the size of the head component and the risk of revision in resurfacing hip arthroplasty. Hips with a femoral component size of ≤ 44 mm have a fivefold increased risk of revision than those with femoral components of ≥ 55 mm irrespective of gender. We have reviewed the literature to explore this observation and to identify possible reasons including the design of the implant, loading of the femoral neck, the orientation of the component, the production of wear debris and the effects of metal ions, penetration of cement and vascularity of the femoral head. Our conclusion is that although multifactorial, the most important contributors to failure in resurfacing arthroplasty of the hip are likely to be the design and geometry of the component and the orientation of the acetabular component


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 465 - 468
1 Aug 1982
McDonald I

Twenty-six patients with rheumatoid arthritis who had undergone bilateral replacement of the hip and knee were reviewed at a mean follow-up time of 51.6 months. A further operation was necessary in five patients due to complications of replacement of the knee, and seven patients still had significant pain in at least one replaced joint. There were no cases of infection due to operation. Seventeen of the patients still used walking aids, but one-third of these did so because of pain in joints that had not been replaced. Patients preferred painless total replacement of the hip to that of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 4 | Pages 561 - 566
1 Nov 1954
Devas MB

All the cup and replacement arthroplasties of the hip at the Middlesex Hospital performed two or more years ago—110 cases—have been reviewed. Cup arthroplasty was the more successful


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 922 - 928
1 Jul 2010
Bose VC Baruah BD

We performed 96 Birmingham resurfacing arthroplasties of the hip in 71 consecutive patients with avascular necrosis of the femoral head. A modified neck-capsule-preserving approach was used which is described in detail. The University of California, Los Angeles outcome score, the radiological parameters and survival rates were assessed. The mean follow-up was for 5.4 years (4.0 to 8.1). All the patients remained active with a mean University of California, Los Angeles activity score of 6.86 (6 to 9). Three hips failed, giving a cumulative survival rate of 95.4%. With failure of the femoral component as the endpoint, the cumulative survival rate was 98.0%. We also describe the combined abduction-valgus angle of the bearing couple, which is the sum of the inclination angle of the acetabular component and the stem-shaft angle, as an index of the optimum positioning of the components in the coronal plane. Using a modified surgical technique, it is possible to preserve the femoral head in avascular necrosis by performing hip resurfacing in patients with good results


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 4 | Pages 614 - 622
1 Nov 1957
Denham RA Alexander WL

1. Two hundred and eleven cases of arthroplasty of the hip have been studied in an attempt to establish the causes of success and failure by comparing the excellent, good and bad results. 2. The findings suggest that the result of an arthroplasty depends largely upon four factors: the surgical approach to the hip joint, the acetabular roof, the interposition substance, and the early post-operative complications. 3. Some important points in the technique of operation and in the post-operative management are described


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 892 - 900
1 Jul 2016
Atrey A Heylen S Gosling O Porteous MJL Haddad FS

Joint replacement of the hip and knee remain very satisfactory operations. They are, however, expensive. The actual manufacturing of the implant represents only 30% of the final cost, while sales and marketing represent 40%. Recently, the patents on many well established and successful implants have expired. Companies have started producing and distributing implants that purport to replicate existing implants with good long-term results. The aims of this paper are to assess the legality, the monitoring and cost saving implications of such generic implants. We also assess how this might affect the traditional orthopaedic implant companies. Cite this article: Bone Joint J 2016;98-B:892–900


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 1 | Pages 44 - 47
1 Feb 1976
Haw C Gray D

The results of excision arthroplasty on forty hips in thirty-two patients have been studied by personal review. The mean follow-up was ten years and the results were graded in the Lazansky system. The outcome was fairly predictable, most patients achieving a fair to good result. The patients were satisfied with the operation in unilateral cases as a secondary operation, but it was generally unsatisfactory as a primary procedure or when performed bilaterally. Pain relief was satisfactory, and previously infected hips achieved sound wound and bone healing. Half could walk with no aid or one stick. No correlation could be found between the radiological appearances and the quality of the result


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 35 - 39
1 Jan 2006
Beaulé PE Campbell PA Hoke R Dorey F

During hip resurfacing arthroplasty, excessive valgus positioning or surgical technique can result in notching of the femoral neck. Although mechanical weakening and subsequent fracture of the femoral neck are well described, the potential damage to the retinacular vessels leading to an ischaemic event is relatively unknown. Using laser Doppler flowmetry, we measured the blood flow in 14 osteoarthritic femoral heads during routine total hip replacement surgery, before and after notching of the femoral neck. In ten hips there was a reduction in blood flow of more than 50% from the baseline value after simulated notching of the femoral neck. Our results suggest that femoral head vascularity in the osteoarthritic state is similar to the non-arthritic state, where damage to the extraosseous vessels can predispose to avascular necrosis. Surgeons who perform resurfacing arthroplasty of the hip should pay careful attention to these vessels by avoiding excessive dissection around the femoral neck and/or notching


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 4 | Pages 393 - 397
1 Nov 1977
Williams E Taylor A Arden G Edwards D

In fifty-six patients with ankylosing spondylitis three types of arthroplasty had been performed in ninety-nine hips. Forty-one of the patients were men and fifteen were women, their average age at operation being forty-two years. Primary pseudarthrosis produced well-satisfied patients, but only a fair result in five hips, whereas cup arthroplasty resulted in a poor outcome for eight hips, all of which needed revision. Total replacement of eighty-six hips, however, led to 73 per cent being graded as good or excellent up to ten years later. The main complications were deep infection of five hips, para-articular ossification around nine hips (six leading to bony ankylosis), and fibrous ankylosis of six hips


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 2 | Pages 191 - 197
1 May 1964
Charnley J Ferreira ADS

1 . The results of transplanting the greater trochanter in 225 "low-friction" arthroplasties of the hip have been examined. 2. Non-union occurred in an average of 7 per cent of cases. 3. When non-union occurred the results still showed improvement. 4. Four different methods of fixation were used, of which that using two wires, crossed in the horizontal and coronal planes, never failed to secure union. 5. Transplantation of the greater trochanter to the best position is only possible if the neck of the femur is shortened or if the centre of motion of the arthroplasty is displaced medially by deepening the acetabulum, or by a combination of both. 6. In the best position the transplanted trochanter considerably improved active abduction against gravity


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 538 - 541
1 Apr 2007
De Haan R Campbell P Reid S Skipor AK De Smet K

A prospective study of serum and urinary ion levels was undertaken in a triathlete who had undergone a metal-on-metal resurfacing arthroplasty of the hip four years previously. The one month study period included the final two weeks of training, the day of the triathlon, and the two weeks immediately post-race. Serum cobalt and chromium levels did not vary significantly throughout this period, including levels recorded on the day after the 11-hour triathlon. Urinary excretion of chromium increased immediately after the race and had returned to pre-race levels six days later. The clinical implications are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1019 - 1024
1 Aug 2007
Hing CB Young DA Dalziel RE Bailey M Back DL Shimmin AJ

Narrowing of the femoral neck after resurfacing arthroplasty of the hip has been described previously in both cemented and uncemented hip resurfacing. The natural history of narrowing of the femoral neck is unknown. We retrospectively measured the diameter of the femoral neck in a series of 163 Birmingham hip resurfacings in 163 patients up to a maximum of six years after operation to determine the extent and progression of narrowing. There were 105 men and 58 women with a mean age of 52 years (18 to 82). At a mean follow-up of five years, the mean Harris hip score was 94.8 (47 to 100) and the mean flexion of the hip 112.5° (80° to 160°). There was some narrowing of the femoral neck in 77% (125) of the patients reviewed, and in 27.6% (45) the narrowing exceeded 10% of the diameter of the neck. A multiple logistic regression analysis showed a significant association (chi-squared test (derived from logistic regression) p = 0.01) of narrowing with female gender and a valgus femoral neck/shaft angle. There was no significant association between the range of movement, position or size of the component or radiological lucent lines and narrowing of the neck (chi-squared test; p = 0.10 (flexion), p = 0.08 (size of femoral component), p = 0.09 (size of acetabular component), p = 0.71 (femoral component angulation), p = 0.99 (lucent lines)). There was no significant difference between the diameter of the neck at a mean of three years (2.5 to 3.5) and that at five years (4.5 to 5.5), indicating that any change in the diameter of the neck had stabilised by three years (sign rank test, p = 0.60). We conclude that narrowing of the femoral neck which is found with the Birmingham hip resurfacing arthroplasty is in most cases associated with no adverse clinical or radiological outcome up to a maximum of six years after the initial operation


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 4 | Pages 720 - 731
1 Nov 1968
Ring PA

1. A complete replacement arthroplasty of the hip is described in which both components are inherently stable. 2. The arthroplasty does not require the use of acrylic cement. 3. It is appropriate for the treatment of the severely arthritic hip in which arthrodesis is not indicated, and for the mobilisation of two stiff and painful hips at any age. 4. It can be performed on both sides at the same time. 5. It produces a stable, pain-free and mobile joint in a high proportion of cases, and has appeared not to deteriorate over periods of up to four years


The Journal of Bone & Joint Surgery British Volume
Vol. 32-B, Issue 2 | Pages 166 - 173
1 May 1950
Judet J Judet R

We have endeavoured to make known the results of a simple type of arthroplasty of the hip which is well tolerated even by elderly patients. It has not been the purpose of this article to compare former operations with our own, a newcomer in the field of surgery of the hip. In particular we do not wish to compare our comparatively recent results with Smith-Petersen's well-established method of cup arthroplasty—a magnificent contribution to the surgery of the region. The results we have already obtained, however, appear sufficiently favourable to merit further study and development of the method. If the future confirms the value of our early results, we shall perhaps be able to suggest operation to patients who suffer more from loss of function than from pain


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 1 | Pages 59 - 75
1 Feb 1948
Smith-Petersen MN

This is the first time that the principle of the mould—the principle of guiding the repair of nature for the purpose of recreating a destroyed or damaged structure, has been applied to surgery. The evolution of the method to its present encouraging stage is the result of the co-operative, professional family spirit of the Massachusetts General Hospital. We all share in it. We share it with the general surgeon because of his contributions to surgical technique. We share it with the "medical man" because of his pre-operative and post-operative care of the patient; because of his guidance as to when, and when not, to operate; and because of the many friendly arguments which are productive of so much good. We share it with the anaesthetist because of his clinical judgment of the patient, his selection of anaesthetic agent, and his continuous, conscientious administration of the anaesthetic throughout the operation. I am going to change from "we" to "I." I owe so much to my assistants, from the first to the last: Bill Rogers, Eddie Cave, George Van Gorder, Paul Norton, Milton Thompson, Otto Aufranc, and Carroll Larson. I want to thank them all for helping to carry the load, for remembering the things that I forgot, and for making helpful suggestions which often led to improvement in surgical technique or to the construction of a useful instrument. I want to pay tribute to the staff of the Orthopaedic Service of the Massachusetts General Hospital and to thank its members for kindly scepticism, constructive criticism, and neverfailing loyal support. The subject of this lecture, "Evolution of Mould Arthroplasty of the Hip Joint," is appropriate for a Moynihan lecture. It is not the work of one man alone. It is the work of one man, supported by a co-operative, helpful, and friendly hospital staff. This is what Lord Moynihan strove so hard to bring about at a time when surgeons viewed one another as rivals. To quote Dr William Mayo: "It is to Lord Moynihan's everlasting credit that, largely as a result of his unceasing efforts, surgeons came to consider themselves as fellow-workers in a cause."


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 741 - 744
1 May 2005
Beaulé PE Krismer M Mayrhofer P Wanner S Le Duff M Mattesich M Stoeckl B Amstutz HC Biedermann R

Studies on the migration of an implant may be the only way of monitoring the early performance of metal-on-metal prostheses. The Ein Bild Roentgen Analyse - femoral component analysis (EBRA-FCA) method was adapted to measure migration of the femoral component in a metal-on-metal surface arthroplasty of the hip using standard antero-posterior radiographs. In order to determine the accuracy and precision of this method a prosthesis was implanted into cadaver bones. Eleven series of radiographs were used to perform a zero-migration study. After adjustment of the femoral component to simulate migration of 3 mm the radiographs were repeated. All were measured independently by three different observers. The accuracy of the method was found to be ± 1.6 mm for the x-direction and ± 2 mm for the y-direction (95% percentile). The method was validated using 28 hips with a minimum follow-up of 3.5 years after arthroplasty. Seventeen were sound, but 11 had failed because of loosening of the femoral component. The normal (control) group had a different pattern of migration compared with that of the loose group. At 29.2 months, the control group showed a mean migration of 1.62 mm and 1.05 mm compared with 4.39 mm and 4.05 mm in the failed group, for the centre of the head and the tip of the stem, respectively (p = 0.001). In the failed group, the mean time to migration greater than 2 mm was earlier than the onset of clinical symptoms or radiological evidence of failure, 19.1 versus 32.2 months (p = 0.001) and 24.8 months (p = 0.012), respectively. EBRA-FCA is a reliable and valid tool for measuring migration of the femoral component after surface arthroplasty and can be used to predict early failure of the implant. It may be of value in determining the long-term performance of surface arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 31 - 34
1 Jan 2006
Loughead JM Starks I Chesney D Matthews JNS McCaskie AW Holland JP

Resurfacing arthroplasty of the hip is being performed more frequently in the United Kingdom. The majority of these patients are younger than 55 years of age, and in this group the key benefits include conservation of femoral bone stock and the potential reduction in the rate of dislocation afforded by the larger resurfacing head. Early aseptic loosening is well recognised in patients younger than 55 years of age, and proponents of resurfacing believe that the improved wear characteristics of the metal-on-metal bearing may improve the long-term survival of this implant. There has been some concern, however, that resurfacing may not be conservative of acetabular bone. We compared a series of 33 consecutive patients who had a hybrid total hip arthroplasty with an uncemented acetabular component and a cemented femoral implant, with 35 patients undergoing a Birmingham hip resurfacing arthroplasty. We compared the diameter of the implanted acetabulum in both groups and, because they were not directly comparable, we corrected for patient size by measuring the diameter of the contralateral femoral head. The data were analysed using unpaired t-tests and analysis of covariance. There was a significantly larger acetabulum in the Birmingham arthroplasty group (mean diameter 56.6 mm vs 52.0 mm; p < 0.001). However, this group had a significantly larger femoral head diameter on the contralateral side (p = 0.03). Analysis of covariance revealed a significant difference between the mean size of the acetabular component implanted in the two operations. The greatest difference in the size of acetabulum was in those patients with a larger diameter of the femoral head. This study shows that more bone is removed from the acetabulum in hip resurfacing than during hybrid total hip arthroplasty, a difference which is most marked in larger patients


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 258 - 264
1 Mar 1997
Nakata K Ohzono K Masuhara K Matsui M Hiroshima K Ochi T

We have reviewed 65 bipolar arthroplasties of the hip in 55 patients with osteoarthritis secondary to dysplasia. The mean age at operation was 56 years (42 to 79) and the mean period of follow-up was 7.2 years (5.0 to 13.0). The average Merle d’Aubigné and Postel score before operation was 10.3 and at final follow-up 15.0. There were excellent or good results in 42 hips (65%). Migration of the outer head was observed in 50 hips (77%), most often in the group with a centre-edge angle of less than 0°, an acetabular head index of less than 60%, coverage of the outer head by the original acetabulum of less than +10° and after bone grafting of the acetabulum. This migration was progressive in 31 (62%) of the 50 hips, with massive osteolysis of the acetabulum in eight. The extent and progression of migration were closely associated with this osteolysis. Four hips required revision for extensive migration of the outer head with destruction of the acetabulum or severe acetabular osteolysis, and nine hips are awaiting revision for failure of the bipolar prosthetic head. The overall failure rate was 18%. We report major problems after bipolar hip arthroplasty for osteoarthritis secondary to hip dysplasia with progressive migration of the outer head and massive acetabular osteolysis at five years or more after operation


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1652 - 1653
1 Dec 2006
Bowman NK Bucher TA Bassily AA

Resurfacing arthroplasties of the hip are being undertaken with increasing frequency and the complications associated with this procedure are well documented. We have encountered a further problem with a fracture of the centralising peg of the femoral component in a prosthesis which had been in situ for three years


Bone & Joint Open
Vol. 4, Issue 3 | Pages 198 - 204
16 Mar 2023
Ramsay N Close JCT Harris IA Harvey LA

Aims. Cementing in arthroplasty for hip fracture is associated with improved postoperative function, but may have an increased risk of early mortality compared to uncemented fixation. Quantifying this mortality risk is important in providing safe patient care. This study investigated the association between cement use in arthroplasty and mortality at 30 days and one year in patients aged 50 years and over with hip fracture. Methods. This retrospective cohort study used linked data from the Australian Hip Fracture Registry and the National Death Index. Descriptive analysis and Kaplan-Meier survival curves tested the unadjusted association of mortality between cemented and uncemented procedures. Multilevel logistic regression, adjusted for covariates, tested the association between cement use and 30-day mortality following arthroplasty. Given the known institutional variation in preference for cemented fixation, an instrumental variable analysis was also performed to minimize the effect of unknown confounders. Adjusted Cox modelling analyzed the association between cement use and mortality at 30 days and one year following surgery. Results. The 30-day mortality was 6.9% for cemented and 4.9% for uncemented groups (p = 0.003). Cement use was significantly associated with 30-day mortality in the Kaplan-Meier survival curve (p = 0.003). After adjusting for covariates, no significant association between cement use and 30-day mortality was shown in the adjusted multilevel logistic regression (odd rati0 (OR) 1.1, 95% confidence interval (CI) 0.9 to 1.5; p = 0.366), or in the instrumental variable analysis (OR 1.0, 95% CI 0.9 to 1.0, p=0.524). There was no significant between-group difference in mortality within 30days (hazard ratio (HR) 0.9, 95% CI 0.7to 1.1; p = 0.355) or one year (HR 0.9 95% CI 0.8 to 1.1; p = 0.328) in the Cox modelling. Conclusion. No statistically significant difference in patient mortality with cement use in arthroplasty was demonstrated in this population, once adjusted for covariates. This study concludes that cementing in arthroplasty for hip fracture is a safe means of surgical fixation. Cite this article: Bone Jt Open 2023;4(3):198–204


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1143 - 1151
1 Sep 2008
Langton DJ Jameson SS Joyce TJ Webb J Nargol AVF

Increased concentrations of metal ions after metal-on-metal resurfacing arthroplasty of the hip remain a concern. Although there has been no proven link to long-term health problems or early prosthetic failure, variables associated with high metal ion concentrations should be identified and, if possible, corrected. Our study provides data on metal ion levels from a series of 76 consecutive patients (76 hips) after resurfacing arthroplasty with the Articular Surface Replacement. Chromium and cobalt ion concentrations in the whole blood of patients with smaller (≤ 51 mm) femoral components were significantly higher than in those with the larger (≥ 53 mm) components (p < 0.01). Ion concentrations in the former group were significantly related to the inclination (p = 0.01) and anteversion (p = 0.01) of the acetabular component. The same relationships were not significant in the patients with larger femoral components (p = 0.61 and p = 0.49, respectively). Accurate positioning of the acetabular component intra-operatively is essential in order to reduce the concentration of metal ions in the blood after hip resurfacing arthroplasty with the Articular Surface Replacement implant


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 4 | Pages 498 - 503
1 Nov 1978
Colville J Raunio P

During the years 1971 to 1975, 378 Charnley low-friction arthroplasties of the hip were performed on 278 patients with rheumatoid arthritis. The average age at operation was thirty-nine years. The follow-up time ranged from one to six years (mean two and a half years). Forty per cent of patients were receiving steroids at the time of operation. The most common complications were loosening of the prosthesis (3.4%), perforation of the femoral cortex and fracture. Deep infection occurred in 0.7%, dislocation in 0.7%, and thromboembolic episodes in 1.3%. Ninety-five per cent of patients were free of pain at follow-up compared to 84% who were severely handicapped by pain before operation. In addition, the increased mobility in 98.5% of patients and their improved independence makes hip replacement a recommendable procedure in these patients


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 14 - 17
1 Jan 2016
Sentuerk U von Roth P Perka C

The leading indication for revision total hip arthroplasty (THA) remains aseptic loosening owing to wear. The younger, more active patients currently undergoing THA present unprecedented demands on the bearings. Ceramic-on-ceramic (CoC) bearings have consistently shown the lowest rates of wear. The recent advances, especially involving alumina/zirconia composite ceramic, have led to substantial improvements and good results in vitro.

Alumina/zirconia composite ceramics are extremely hard, scratch resistant and biocompatible. They offer a low co-efficient of friction and superior lubrication and lower rates of wear compared with other bearings. The major disadvantage is the risk of fracture of the ceramic. The new composite ceramic has reduced the risk of fracture of the femoral head to 0.002%. The risk of fracture of the liner is slightly higher (0.02%).

Assuming that the components are introduced without impingement, CoC bearings have major advantages over other bearings. Owing to the superior hardness, they produce less third body wear and are less vulnerable to intra-operative damage.

The improved tribology means that CoC bearings are an excellent choice for young, active patients requiring THA.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):14–17.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 818 - 821
1 Jun 2006
Girard J Vendittoli P Lavigne M Roy AG

A 34-year-old woman with a benign form of osteopetrosis developed osteoarthritis of the hip. In order to avoid the difficulties associated with inserting the femoral component of a conventional total hip arthroplasty, a hybrid metal-on-metal resurfacing was performed. There were several technical challenges associated with the procedure, including the sizing of the component, press-fit fixation of the acetabular component and femoral head preparation, as well as trying to avoid a fracture. No surgical complication occurred. After more than a year following surgery, the patient showed excellent clinical function and remained satisfied with the outcome. We conclude that the hybrid metal-on-metal resurfacing arthroplasty represents a valuable option for the treatment of patients with osteopetrosis and secondary hip osteoarthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 278 - 278
1 Feb 2005
HAMILTON H


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 620 - 621
1 May 2003
ELSON RA


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 335 - 338
1 Apr 2002
White TO Dougall TW

Discrepancy in leg length after total hip replacement has been associated with patient dissatisfaction. We prospectively studied 200 consecutive patients undergoing unilateral Charnley hip replacements to identify whether there is a demonstrable association between such disparity and postoperative function. Radiological measurements between defined points on the pelvis and femur of the operated hip were compared with the same points on the contralateral joint. A lengthening index was derived and statistical analysis used to compare this with validated functional outcome scores (Harris hip score and the SF36 Health Survey) and patient satisfaction.

Our results showed no statistical association between leg-length discrepancy after hip arthroplasty and functional outcome or patient satisfaction.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1158 - 1163
1 Sep 2008
De Haan R Campbell PA Su EP De Smet KA

We have reviewed 42 patients who had revision of metal-on-metal resurfacing procedures, mostly because of problems with the acetabular component. The revisions were carried out a mean of 26.2 months (1 to 76) after the initial operation and most of the patients (30) were female.

Malpositioning of the acetabular component resulted in 27 revisions, mostly because of excessive abduction (mean 69.9°; 56° to 98°) or insufficient or excessive anteversion. Seven patients had more than one reason for revision. The mean increase in the diameter of the component was 1.8 mm (0 to 4) when exchange was needed.

Malpositioning of the components was associated with metallosis and a high level of serum ions. The results of revision of the femoral component to a component with a modular head were excellent, but four patients had dislocation after revision and four required a further revision.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 157 - 158
1 Mar 2004
Villar R


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 4 | Pages 576 - 577
1 Nov 1972
Bonnin JG


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1642 - 1647
1 Dec 2010
deSouza RM Parsons NR Oni T Dalton P Costa M Krikler S

We report serum metal ion level data in patients with unilateral and bilateral hip resurfacing over a ten-year period. In these patients there is an increase in both cobalt and chromium levels above the accepted reference ranges during the first 18 months after operation. Metal ion levels remain elevated, but decline slowly for up to five years. However, the levels then appear to start rising again in some patients up to the ten-year mark. There was no significant difference in cobalt or chromium levels between men and women. These findings appear to differ from much of the current literature.

The clinical significance of a raised metal ion level remains under investigation.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1117 - 1117
1 Aug 2006
MUIRHEAD-ALLWOOD SK PATEL C MOHANDAS P


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 838 - 838
1 Jun 2006
BEAULÉ PE


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 1 | Pages 44 - 58
1 Feb 1974
Ring PA

1. A thousand arthritic hips have been replaced by an uncemented metal-on-metal prosthesis, and 942 followed by annual review. The mortality of the operation has been 1·1 per cent, the rate of deep-seated infection 0·7 per cent and the incidence of dislocation 0·3 per cent.

2. Of 169 hips replaced by an earlier type of the prosthesis and followed for five to eight years, 45 per cent have remained excellent and 29 per cent good, but 14 per cent have required revision, mainly for loosening of the femoral component.

3. The current types of prosthesis, now used for five years, have given excellent results in 69 per cent and good results in 21 per cent of 535 patients followed for one to five years. Revision for loosening has been necessary in 2 per cent.

4. The improvement in results has been obtained by the introduction of a tapered screw thread on the pelvic component, and by a range of femoral components that ensures a good cortical fit.


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 2 | Pages 199 - 208
1 May 1953
Adams JC

1. The unreliable results of the conventional cup arthroplasty are attributed to mechanical imperfections in the reconstructed joint.

2. If its reliability can be improved, there will remain a place for cup arthroplasty, which, in relatively young and active patients, offers advantages over prosthetic replacement arthroplasty.

3. A technique of concentric cup arthroplasty is described. The new joint is shaped with precision to exact dimensions and lined with a cup designed to ensure stability, concentric movement and a uniform clearance between the moving parts.

4. The results so far are encouraging and justify continued clinical trial.


The Journal of Bone & Joint Surgery British Volume
Vol. 34-B, Issue 2 | Pages 308 - 310
1 May 1952
Valls J


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 427 - 430
1 May 1999
Wroblewski BM Fleming PA Siney PD

We reviewed 261 patients with 320 Charnley low-friction arthroplasties who had a mean follow-up of 22 years 10 months (20 to 30). Of these, 93.9% considered the operation to be a success; 82.3% were free from pain and 11.6% had occasional discomfort. Satisfactory function was achieved in 59.6% and 62% had an excellent range of movement.

The clinical results did not correlate well with the radiological appearance; radiologically loose components did not affect the clinical outcome. The main long-term problem was wear and loosening of the UHMWPE cup. Our findings suggest that the radiological appearance of the arthroplasty is a more reliable indication of the state of the arthroplasty than the clinical results.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 465 - 470
1 May 1989
Clarke H Jinnah R Brooker A Michaelson J

Total hip replacement was performed in 27 hips of patients who had sickle cell anaemia with avascular necrosis of the femoral head. The disease was bilateral in 11 patients. Considerable medical problems were encountered although most of the patients had exchange transfusion before surgery (86%), which prevented postoperative sickle cell crises in all but two cases. At the primary operation hard sclerotic bone was seen in nine femora with complete obliteration of the femoral canal. There were four femoral fractures, three following perforation of the shaft due to this hard bone. There was a very high morbidity due to loosening in both cemented and uncemented prostheses. With a rate of 59% over a cumulative 5.5 year period, revision was being performed at an average of only 43 months. Surgeons should be aware of these problems.


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 3 | Pages 354 - 363
1 Aug 1954
Shepherd MM


The Journal of Bone & Joint Surgery British Volume
Vol. 33-B, Issue 4 | Pages 634 - 635
1 Nov 1951
Charnley J Wright JK


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 838 - 838
1 Jun 2006
SPENCER RF


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 838 - 839
1 Jun 2006
VENDITTOLI P LAVIGNE M ROY A GIRARD J


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 839 - 839
1 Jun 2006
ROBERTS P GRIGORIS P


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 844 - 850
1 Jun 2005
Ridgeway S Wilson J Charlet A Kafatos G Pearson A Coello R

We wished to estimate the incidence of surgical-site infection (SSI) after total hip replacement (THR) and hemiarthroplasty and its strength of association with major risk factors. The SSI surveillance service prospectively gathered clinical, operative and infection data on inpatients from 102 hospitals in England during a four-year period.

The overall incidence of SSI was 2.23% for 16 291 THRs, 4.97% for 5769 hemiarthroplasty procedures, 3.68% for 2550 revision THRs and 7.6% for 198 revision hemiarthroplasties. Staphylococcus aureus was identified in 50% of SSIs; 59% of these isolates were methicillin-resistant (MRSA). In the single variable analysis of THRs, age, female gender, American Society of Anesthesiologists (ASA) score, body mass index, trauma, duration of operation and pre-operative stay were significantly associated with the risk of SSI (p < 0.05). For hemiarthroplasty, the ASA score and age were significant factors. In revision THRs male gender, ASA score, trauma, wound class, duration of operation and pre-operative stay were significant risk factors. The median time to detection of SSI was eight days for superficial incisional, 11 days for deep incisional and 11 days for joint/bone infections. For each procedure the mean length of stay doubled for patients with SSI. The multivariate analysis identified age group, trauma, duration of operation and ASA score as significant, independent risk factors for SSI. There was significant interhospital variation in the rates of SSI. MRSA was the most common pathogen to cause SSI in hip arthroplasty, especially in patients undergoing hemiarthroplasty, but coagulase-negative Staph. aureus may be more important in deep infections involving the joint.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 549 - 556
1 Apr 2007
Udofia I Liu F Jin Z Roberts P Grigoris P

Finite element analysis was used to examine the initial stability after hip resurfacing and the effect of the procedure on the contact mechanics at the articulating surfaces. Models were created with the components positioned anatomically and loaded physiologically through major muscle forces. Total micromovement of less than 10 μm was predicted for the press-fit acetabular components models, much below the 50 μm limit required to encourage osseointegration. Relatively high compressive acetabular and contact stresses were observed in these models. The press-fit procedure showed a moderate influence on the contact mechanics at the bearing surfaces, but produced marked deformation of the acetabular components. No edge contact was predicted for the acetabular components studied.

It is concluded that the frictional compressive stresses generated by the 1 mm to 2 mm interference-fit acetabular components, together with the minimal micromovement, would provide adequate stability for the implant, at least in the immediate post-operative situation.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 774 - 774
1 Jul 2003
SHARMA S


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 320 - 323
1 Mar 2005
Little CP Ruiz AL Harding IJ McLardy-Smith P Gundle R Murray DW Athanasou NA

We present the histological findings of bone retrieved from beneath the femoral components of failed metal-on-metal hip resurfacing arthroplasties. Of a total of 377 patients who underwent resurfacing arthroplasty, 13 required revision; for fracture of the femoral neck in eight, loosening of a component in three and for other reasons in two. None of these cases had shown histological evidence of osteonecrosis in the femoral bone at the time of the initial implantation.

Bone from the remnant of the femoral head showed changes of osteonecrosis in all but one case at revision. In two cases of fracture which occurred within a week of implantation, the changes were compatible with early necrosis of the edge of the fracture. In the remaining six fractures, there were changes of established osteonecrosis. In all but one of the non-fracture cases, patchy osteonecrosis was seen.

We conclude that histological evidence of osteonecrosis is a common finding in failed resurfaced hips. Given that osteonecrosis is extensive in resurfaced femoral heads which fail by fracture, it is likely to play a role in the causation of these fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 1 | Pages 77 - 87
1 Feb 1972
Dupont JA Charnley J

1. Two hundred and seventeen low-friction arthroplasties performed between November 1962 and April 1969 in 203 patients with failed previous operations have been analysed.

2. The technical details of operation in relation to these conversion problems have been outlined.

3. The quality of the results in relation to pain, mobility and ability to walk has been assessed before operation and one year afterwards, with small numbers at three and five years.

4. Pain was completely relieved or was minimal in 96·3 per cent of the patients, and in no case was the pain worse.

5. The total range of movement was 100 degrees or more in 98·5 per cent. No hip lost movement after conversion.

6. The failures were principally due to infection and to technical difficulties. There were no mechanical failures without a technical or radiological explanation.

7. Low-friction arthroplasty is an excellent salvage procedure, especially for failed cup arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 583 - 588
1 May 2009
Rasch A Byström AH Dalén N Martinez-Carranza N Berg HE

Muscle atrophy has been demonstrated in patients suffering from osteoarthritis of the hip, but little is known about muscular recovery after total hip replacement (THR). A total of 20 patients with unilateral osteoarthritis of the hip were assessed before, six months and two years after THR. The cross-sectional area and radiological density of the muscles of the hip, thigh, calf and back were measured using CT. We hypothesised that the muscles would not recover fully after operation.

After two years comparison of the limb with the THR with the healthy limb showed that there was such a reduction in the cross-sectional area in iliopsoas (7.0%; p = 0.006) and the hip adductors (8.4%, p = 0.003) and in the radiological density in gluteus maximus (10.1 Hounsfield units; p < 0.001), gluteus medius/minimus (5.6 Hounsfield units; p = 0.011), iliopsoas (3.9 Hounsfield units; p < 0.001) and the adductors (2.4 Hounsfield units; p = 0.022).

Thus, there was persistent muscle atrophy in muscles acting about the hip two years after THR. We suggest that an earlier operation or a more intensive rehabilitation may reverse these changes.