The purpose of this study was to assess whether
the use of a joint-sparing technique such as curettage and grafting was
successful in eradicating
Aims.
A
Aims. Tenosynovial
Aims. We performed a systematic literature review to define features of patients, treatment, and biological behaviour of multicentric
Aims. The present study investigated receptor activator of nuclear factor kappa-Β ligand (RANKL), osteoprotegerin (OPG), and Runt-related transcription factor 2 (RUNX2) gene expressions in
Aims. Local recurrence remains a challenging and common problem following curettage and joint-sparing surgery for
Aims.
We retrospectively studied local recurrence of
Aims. Tenosynovial
Aims.
Aims. There is a lack of evidence about the risk factors for local recurrence of a
Aims. The aim of this paper was to investigate the prognostic factors for local recurrence in patients with pathological fracture through
Aims. The aim of this study was to evaluate health-related quality of life (HRQoL) and joint function in tenosynovial
Aims. To investigate the benefits of denosumab in combination with nerve-sparing surgery for treatment of sacral
We investigated whether the presence of a pathological
fracture increased the risk of local recurrence in patients with
a
We report a case of benign
We retrospectively compared the outcome after
the treatment of
The August 2023 Oncology Roundup360 looks at:
Aims. The aim of this study was to determine the rate of indocyanine green (ICG) staining of bone and soft-tissue tumours, as well as the stability and accuracy of ICG fluorescence imaging in detecting tumour residuals during surgery for bone and soft-tissue tumours. Methods. ICG fluorescence imaging was performed during surgery in 34 patients with bone and soft-tissue tumours. ICG was administered intravenously at a dose of 2 mg/kg over a period of 60 minutes on the day prior to surgery. The tumour stain rate and signal-to-background ratio of each tumour were post hoc analyzed. After tumour resection, the tumour bed was scanned to locate sites with fluorescence residuals, which were subsequently inspected and biopsied. Results. The overall tumour stain rate was 88% (30/34 patients), and specific stain rates included 90% for osteosarcomas and 92% for
The June 2024 Oncology Roundup. 360. looks at: Chondrosarcoma of the femur: is local recurrence influenced by the presence of an extraosseous component?; Diagnostic challenges in low-grade central osteosarcoma; Single osteotomy technique for frozen autograft (pedicled freezing) in patients with malignant bone tumours; Unplanned resection for small superficial soft-tissue sarcomas: disastrous or simply bad?; Inactivation and replantation of the knee joint: an infeasible surgical method; Active surveillance of diffuse-type tenosynovial
The August 2023 Knee Roundup. 360. looks at: Curettage and cementation of
The April 2015 Oncology Roundup. 360 . looks at: New hope for skull base tumours; Survival but at what cost?; Synovial sarcoma beginning to be cracked?; Wound complications facing soft-tissue sarcoma surgeons; Amputation may offer no survival benefit over reconstruction;
The April 2012 Oncology Roundup. 360 . looks at chondrosarcoma of the cervical spine, if excision margins matter, radiation-induced sarcomas,
The August 2012 Oncology Roundup. 360. looks at: prolonged symptom duration; peri-operative mortality and above-knee amputation;
Aims. The aims of this study were to evaluate the efficacy of preoperative denosumab in achieving prospectively decided intention of therapy in operable
The April 2014 Oncology Roundup. 360 . looks at: Eyeball as good as microscope for tumour margins; when is best to stabilise femoral metastases?; fluorine does not cause bone tumours; whether
The October 2013 Oncology Roundup. 360 . looks at: En bloc resection, irradiation and re-implantation; Metastasis and osteosarcoma; Mobile spine and osteosarcoma; Denosumab miraculous for GCT; Fevers, megaprostheses and sarcomas; PET and prognosis; Canine sarcomas not so different?; Bone cement and
The August 2015 Oncology Roundup. 360 . looks at: Glasgow prognostic score in soft-tissue sarcoma; Denosumab in
The June 2013 Oncology Roundup. 360 . looks at: whether allograft composite is superior to megaprosthesis in massive reconstruction; pain from glomus tumours; thromboembolism and orthopaedic malignancy; bone marrow aspirate and cavity lesions; metastasectomy in osteosarcoma; spinal
The June 2015 Oncology Roundup. 360 . looks at: Infection in megaprosthesis; Impressive results for mid femoral reconstruction; Revered teaching or old myth? Femoral neck protection in metastatic disease; Megaprosthesis about the knee; Malignant transformation in multiple hereditary exostoses; Fracture of intercalary bone allograft; Comorbidity and outcomes in sarcoma; A worrying turn? Use of denosumab for
We report our experience of treating 17 patients with benign lesions of the proximal femur with non-vascularised, autologous fibular strut grafts, without osteosynthesis. The mean age of the patients at presentation was 16.5 years (5 to 33) and they were followed up for a mean of 2.9 years (0.4 to 19.5). Histological diagnoses included simple bone cyst, fibrous dysplasia, aneurysmal bone cysts and
We present a retrospective study of patients suffering from a variety of benign tumours in whom external fixators were used to treat deformity and limb-length discrepancy, and for the reconstruction of bone defects. A total of 43 limbs in 31 patients (12 male and 19 female) with a mean age of 14 years (2 to 54) were treated. The diagnosis was Ollier’s disease in 12 limbs, fibrous dysplasia in 11, osteochondroma in eight,
We describe a schwannoma located in the mid-diaphyseal region of the fibula of a 14-year-old boy. Radiologically this was an expansile, lytic, globular and trabeculated lesion. MRI showed a narrow transition zone with a break in the cortex and adjacent tissue oedema. Differential diagnosis included schwannoma, fibrous dysplasia,
Between June 2005 and March 2008, 14 patients with a Campanacci grade-3 giant-cell tumour of the distal radius were treated by en bloc resection and reconstruction by ulnar translocation with arthrodesis of the wrist. The mean length of radius resected was 7.9 cm (5.5 to 15). All the patients were followed to bony union and 12 were available at a mean follow-up of 26 months (10 to 49). The mean time to union was four months (3 to 7) at the ulnocarpal junction and five months (3 to 8) at the ulnoradial junction. All except one patient had an excellent range of pronation and supination. The remaining patient developed a radio-ulnar synostosis. The mean Musculoskeletal Tumor Society score was 26 (87%, range 20 to 28). Three patients had a soft-tissue recurrence, but with no bony involvement. They underwent a further excision and are currently well and free from disease. Ulnar translocation provides a local vascularised bone graft to reconstruct the defect left after excision of the distal radius for
Tumours of the sacrum are difficult to manage. The sacrum provides the structural connection between the torso and lower half of the body and is subject to both axial and rotational forces. Thus, tumours or their treatment can compromise the stability of the spinopelvic junction. Additionally, nerves responsible for lower limb motor groups as well as bowel, bladder, and sexual function traverse or abut the sacrum. Preservation or sacrifice of these nerves in the treatment of sacral tumours has profound implications on the function and quality of life of the patient. This annotation will discuss current treatment protocols for sacral tumours. Cite this article:
Reconstruction after osteoarticular resection of the proximal ulna for tumours is technically difficult and little has been written about the options that are available. We report a series of four patients who underwent radial neck to humeral trochlea transposition arthroplasty following proximal ulnar osteoarticular resection. Between July 2020 and July 2022, four patients with primary bone tumours of the ulna underwent radial neck to humeral trochlea transposition arthroplasty. Their mean age was 28 years (12 to 41). The functional outcome was assessed using the range of motion (ROM) of the elbow, rotation of the forearm and stability of the elbow, the Musculoskeletal Tumor Society score (MSTS), and the nine-item abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH-9) score.Aims
Methods
The sacroiliac joint (SIJ) is the only mechanical connection between the axial skeleton and lower limbs. Following iliosacral resection, there is debate on whether reconstruction of the joint is necessary. There is a paucity of data comparing the outcomes of patients undergoing reconstruction and those who are not formally reconstructed. A total of 60 patients (25 females, 35 males; mean age 39 years (SD 18)) undergoing iliosacral resection were reviewed. Most resections were performed for primary malignant tumours (n = 54; 90%). The mean follow-up for surviving patients was nine years (2 to 19).Aims
Methods
The proximal tibia (PT) is the anatomical site most frequently affected by primary bone tumours after the distal femur. Reconstruction of the PT remains challenging because of the poor soft-tissue cover and the need to reconstruct the extensor mechanism. Reconstructive techniques include implantation of massive endoprosthesis (megaprosthesis), osteoarticular allografts (OAs), or allograft-prosthesis composites (APCs). This was a retrospective analysis of clinical data relating to patients who underwent proximal tibial arthroplasty in our regional bone tumour centre from 2010 to 2018.Aims
Methods
The April 2023 Oncology Roundup360 looks at: Complete tumour necrosis after neoadjuvant chemotherapy defines good responders in patients with Ewing’s sarcoma; Monitoring vascularized fibular autograft: are radiographs enough?; Examining patient perspectives on sarcoma surveillance; The management of sacral tumours; Venous thromboembolism and major bleeding in the clinical course of osteosarcoma and Ewing’s sarcoma; Secondary malignancies after Ewing’s sarcoma: what is the disease burden?; Outcomes of distal radial endoprostheses for tumour reconstruction: a single centre experience over 15 years; Is anaerobic coverage during soft-tissue sarcoma resection needed?; Is anaerobic coverage during soft-tissue sarcoma resection needed?
The aim of this study was to investigate the safety and efficacy of 3D-printed modular prostheses in patients who underwent joint-sparing limb salvage surgery (JSLSS) for malignant femoral diaphyseal bone tumours. We retrospectively reviewed 17 patients (13 males and four females) with femoral diaphyseal tumours who underwent JSLSS in our hospital.Aims
Methods
Endoprosthetic reconstruction following distal femur tumour resection has been widely advocated. In this paper, we present the design of an uncemented endoprosthesis system featuring a short, curved stem, with the goal of enhancing long-term survivorship and functional outcomes. This study involved patients who underwent implantation of an uncemented distal femoral endoprosthesis with a short and curved stem between 2014 and 2019. Functional outcomes were assessed using the 1993 version of the Musculoskeletal Tumour Society (MSTS-93) score. Additionally, we quantified five types of complications and assessed osseointegration radiologically. The survivorship of the endoprosthesis was evaluated according to two endpoints. A total of 134 patients with a median age of 26 years (IQR 16 to 41) were included in our study. The median follow-up time was 61 months (IQR 56 to 76), and the median functional MSTS-93 was 83% (IQR 73 to 91) postoperatively.Aims
Methods
For rare cases when a tumour infiltrates into the hip joint, extra-articular resection is required to obtain a safe margin. Endoprosthetic reconstruction following tumour resection can effectively ensure local control and improve postoperative function. However, maximizing bone preservation without compromising surgical margin remains a challenge for surgeons due to the complexity of the procedure. The purpose of the current study was to report clinical outcomes of patients who underwent extra-articular resection of the hip joint using a custom-made osteotomy guide and 3D-printed endoprosthesis. We reviewed 15 patients over a five-year period (January 2017 to December 2022) who had undergone extra-articular resection of the hip joint due to malignant tumour using a custom-made osteotomy guide and 3D-printed endoprosthesis. Each of the 15 patients had a single lesion, with six originating from the acetabulum side and nine from the proximal femur. All patients had their posterior column preserved according to the surgical plan.Aims
Methods
This study aimed to analyze the accuracy and errors associated with 3D-printed, patient-specific resection guides (3DP-PSRGs) used for bone tumour resection. We retrospectively reviewed 29 bone tumour resections that used 3DP-PSRGs based on 3D CT and 3D MRI. We evaluated the resection amount errors and resection margin errors relative to the preoperative plans. Guide-fitting errors and guide distortion were evaluated intraoperatively and one month postoperatively, respectively. We categorized each of these error types into three grades (grade 1, < 1 mm; grade 2, 1 to 3 mm; and grade 3, > 3 mm) to evaluate the overall accuracy.Aims
Methods