Advertisement for orthosearch.org.uk
Results 1 - 20 of 64
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1242 - 1247
3 Sep 2020
Hsu P Wu K Lee C Lin S Kuo KN Wang T

Aims. Guided growth has been used to treat coxa valga for cerebral palsy (CP) children. However, there has been no study on the optimal position of screw application. In this paper we have investigated the influence of screw position on the outcomes of guided growth. Methods. We retrospectively analyzed 61 hips in 32 CP children who underwent proximal femoral hemi epiphysiodesis between July 2012 and September 2017. The hips were divided into two groups according to the transphyseal position of the screw in the coronal plane: across medial quarter (Group 1) or middle quarter (Group 2) of the medial half of the physis. We compared pre- and postoperative radiographs in head-shaft angle (HSA), Reimer’s migration percentage (MP), acetabular index (AI), and femoral anteversion angle (FAVA), as well as incidences of the physis growing-off the screw within two years. Linear and Cox regression analysis were conducted to identify factors related to HSA correction and risk of the physis growing-off the screw. Results. A total of 37 hips in Group 1 and 24 hips in Group 2 were compared. Group 1 showed a more substantial decrease in the HSA (p = 0.003) and the MP (p = 0.032). Both groups had significant and similar improvements in the AI (p = 0.809) and the FAVA (p = 0.304). Group 1 presented a higher incidence of the physis growing-off the screw (p = 0.038). Results of the regression analysis indicated that the eccentricity of screw position correlated with HSA correction and increases the risk of the physis growing-off the screw. Conclusion. Guided growth is effective in improving coxa valga and excessive femoral anteversion in CP children. For younger children, despite compromised efficacy of varus correction, we recommend a more centered screw position, at least across the middle quarter of the medial physis, to avoid early revision. Cite this article: Bone Joint J 2020;102-B(9):1242–1247


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 1008 - 1014
1 Sep 2024
Prijs J Rawat J ten Duis K Assink N Harbers JS Doornberg JN Jadav B Jaarsma RL IJpma FFA

Aims. Paediatric triplane fractures and adult trimalleolar ankle fractures both arise from a supination external rotation injury. By relating the experience of adult to paediatric fractures, clarification has been sought on the sequence of injury, ligament involvement, and fracture pattern of triplane fractures. This study explores the similarities between triplane and trimalleolar fractures for each stage of the Lauge-Hansen classification, with the aim of aiding reduction and fixation techniques. Methods. Imaging data of 83 paediatric patients with triplane fractures and 100 adult patients with trimalleolar fractures were collected, and their fracture morphology was compared using fracture maps. Visual fracture maps were assessed, classified, and compared with each other, to establish the progression of injury according to the Lauge-Hansen classification. Results. Four stages of injury in triplane fractures, resembling the adult supination external rotation Lauge-Hansen stages, were observed. Stage I consists of rupture of the anterior syndesmosis or small avulsion of the anterolateral tibia in trimalleolar fractures, and the avulsion of a larger Tillaux fragment in triplanes. Stage II is defined as oblique fracturing of the fibula at the level of the syndesmosis, present in all trimalleolar fractures and in 30% (25/83) of triplane fractures. Stage III is the fracturing of the posterior malleolus. In trimalleolar fractures, the different Haraguchi types can be discerned. In triplane fractures, the delineation of the posterior fragment has a wave-like shape, which is part of the characteristic Y-pattern of triplane fractures, originating from the Tillaux fragment. Stage IV represents a fracture of the medial malleolus, which is highly variable in both the trimalleolar and triplane fractures. Conclusion. The paediatric triplane and adult trimalleolar fractures share common features according to the Lauge-Hansen classification. This highlights that the adolescent injury arises from a combination of ligament traction and a growth plate in the process of closing. With this knowledge, a specific sequence of reduction and optimal screw positions are recommended. Cite this article: Bone Joint J 2024;106-B(9):1008–1014


Bone & Joint Open
Vol. 1, Issue 9 | Pages 594 - 604
24 Sep 2020
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To develop a core outcome set of measurements from postoperative radiographs that can be used to assess technical skill in performing dynamic hip screw (DHS) and hemiarthroplasty, and to validate these against Van der Vleuten’s criteria for effective assessment. Methods. A Delphi exercise was undertaken at a regional major trauma centre to identify candidate measurement items. The feasibility of taking these measurements was tested by two of the authors (HKJ, GTRP). Validity and reliability were examined using the radiographs of operations performed by orthopaedic resident participants (n = 28) of a multicentre randomized controlled educational trial (ISRCTN20431944). Trainees were divided into novice and intermediate groups, defined as having performed < ten or ≥ ten cases each for DHS and hemiarthroplasty at baseline. The procedure-based assessment (PBA) global rating score was assumed as the gold standard assessment for the purposes of concurrent validity. Intra- and inter-rater reliability testing were performed on a random subset of 25 cases. Results. In total, 327 DHS and 248 hemiarthroplasty procedures were performed by 28 postgraduate year (PGY) 3 to 5 orthopaedic trainees during the 2014 to 2015 surgical training year at nine NHS hospitals in the West Midlands, UK. Overall, 109 PBAs were completed for DHS and 80 for hemiarthroplasty. Expert consensus identified four ‘final product analysis’ (FPA) radiological parameters of technical success for DHS: tip-apex distance (TAD); lag screw position in the femoral head; flushness of the plate against the lateral femoral cortex; and eight-cortex hold of the plate screws. Three parameters were identified for hemiarthroplasty: leg length discrepancy; femoral stem alignment; and femoral offset. Face validity, content validity, and feasibility were excellent. For all measurements, performance was better in the intermediate compared with the novice group, and this was statistically significant for TAD (p < 0.001) and femoral stem alignment (p = 0.023). Concurrent validity was poor when measured against global PBA score. This may be explained by the fact that they are measuring difference facets of competence. Intra-and inter-rater reliability were excellent for TAD, moderate for lag screw position (DHS), and moderate for leg length discrepancy (hemiarthroplasty). Use of a large multicentre dataset suggests good generalizability of the results to other settings. Assessment using FPA was time- and cost-effective compared with PBA. Conclusion. Final product analysis using post-implantation radiographs to measure technical skill in hip fracture surgery is feasible, valid, reliable, and cost-effective. It can complement traditional workplace-based assessment for measuring performance in the real-world operating room . It may have particular utility in competency-based training frameworks and for assessing skill transfer from the simulated to live operating theatre. Cite this article: Bone Joint Open 2020;1-9:594–604


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 543 - 550
1 May 2023
Abel F Avrumova F Goldman SN Abjornson C Lebl DR

Aims

The aim of this study was to assess the accuracy of pedicle screw placement, as well as intraoperative factors, radiation exposure, and complication rates in adult patients with degenerative disorders of the thoracic and lumbar spines who have undergone robotic-navigated spinal surgery using a contemporary system.

Methods

The authors reviewed the prospectively collected data on 196 adult patients who had pedicle screws implanted with robot-navigated assistance (RNA) using the Mazor X Stealth system between June 2019 and March 2022. Pedicle screws were implanted by one experienced spinal surgeon after completion of a learning period. The accuracy of pedicle screw placement was determined using intraoperative 3D fluoroscopy.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims

Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery.

Methods

A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group.


Bone & Joint Open
Vol. 4, Issue 5 | Pages 329 - 337
8 May 2023
Khan AQ Chowdhry M Sherwani MKA McPherson EJ

Aims

Total hip arthroplasty (THA) is considered the preferred treatment for displaced proximal femoral neck fractures. However, in many countries this option is economically unviable. To improve outcomes in financially disadvantaged populations, we studied the technique of concomitant valgus hip osteotomy and operative fixation (VOOF). This prospective serial study compares two treatment groups: VOOF versus operative fixation alone with cannulated compression screws (CCSs).

Methods

In the first series, 98 hip fixation procedures were performed using CCS. After fluoroscopic reduction of the fracture, three CCSs were placed. In the second series, 105 VOOF procedures were performed using a closing wedge intertrochanteric osteotomy with a compression lag screw and lateral femoral plate. The alignment goal was to create a modified Pauwel’s fracture angle of 30°. After fluoroscopic reduction of fracture, lag screw was placed to achieve the calculated correction angle, followed by inter-trochanteric osteotomy and placement of barrel plate. Patients were followed for a minimum of two years.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 457 - 463
2 Jun 2024
Coviello M Abate A Maccagnano G Ippolito F Nappi V Abbaticchio AM Caiaffa E Caiaffa V

Aims

Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail.

Methods

A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims

To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture.

Methods

This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty).


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1110 - 1117
12 Oct 2022
Wessling M Gebert C Hakenes T Dudda M Hardes J Frieler S Jeys LM Hanusrichter Y

Aims

The aim of this study was to examine the implant accuracy of custom-made partial pelvis replacements (PPRs) in revision total hip arthroplasty (rTHA). Custom-made implants offer an option to achieve a reconstruction in cases with severe acetabular bone loss. By analyzing implant deviation in CT and radiograph imaging and correlating early clinical complications, we aimed to optimize the usage of custom-made implants.

Methods

A consecutive series of 45 (2014 to 2019) PPRs for Paprosky III defects at rTHA were analyzed comparing the preoperative planning CT scans used to manufacture the implants with postoperative CT scans and radiographs. The anteversion (AV), inclination (IC), deviation from the preoperatively planned implant position, and deviation of the centre of rotation (COR) were explored. Early postoperative complications were recorded, and factors for malpositioning were sought. The mean follow-up was 30 months (SD 19; 6 to 74), with four patients lost to follow-up.


Bone & Joint 360
Vol. 12, Issue 1 | Pages 33 - 35
1 Feb 2023

The February 2023 Spine Roundup360 looks at: S2AI screws: At what cost?; Just how good is spinal deformity surgery?; Is 80 years of age too late in the day for spine surgery?; Factors affecting the accuracy of pedicle screw placement in robot-assisted surgery; Factors causing delay in discharge in patients eligible for ambulatory lumbar fusion surgery; Anterior cervical discectomy or fusion and selective laminoplasty for cervical spondylotic myelopathy; Surgery for cervical radiculopathy: what is the complication burden?; Hypercholesterolemia and neck pain; Return to work after surgery for cervical radiculopathy: a nationwide registry-based observational study.


Bone & Joint Open
Vol. 3, Issue 11 | Pages 859 - 866
4 Nov 2022
Diesel CV Guimarães MR Menegotto SM Pereira AH Pereira AA Bertolucci LH Freitas EC Galia CR

Aims

Our objective was describing an algorithm to identify and prevent vascular injury in patients with intrapelvic components.

Methods

Patients were defined as at risk to vascular injuries when components or cement migrated 5 mm or more beyond the ilioischial line in any of the pelvic incidences (anteroposterior and Judet view). In those patients, a serial investigation was initiated by a CT angiography, followed by a vascular surgeon evaluation. The investigation proceeded if necessary. The main goal was to assure a safe tissue plane between the hardware and the vessels.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 902 - 908
1 Jul 2022
Hsu P Lee C Lin S Kuo KN Wu K Wang T

Aims

The aim of this study was to compare outcomes of guided growth and varus osteotomy in treating Kalamchi type II avascular necrosis (AVN) after open reduction and Pemberton acetabuloplasty for developmental dysplasia of the hip (DDH).

Methods

This retrospective study reviewed patients undergoing guided growth or varus osteotomy for Kalamchi type II AVN between September 2009 and January 2019. All children who had undergone open reduction and Pemberton acetabuloplasty for DDH with a minimum two-year follow-up were enrolled in the study. Demographic and radiological data, which included the head-shaft angle (HSA), neck-shaft angle (NSA), articulotrochanteric distance (ATD), Sharp angle (SA), and lateral centre-edge angle (LCEA) at baseline, two years, and at the extended follow-up, were compared. Revision rates were evaluated. Clinical outcomes using the Harris Hip Score were assessed two years postoperatively.


Bone & Joint Open
Vol. 5, Issue 5 | Pages 385 - 393
13 May 2024
Jamshidi K Toloue Ghamari B Ammar W Mirzaei A

Aims

Ilium is the most common site of pelvic Ewing’s sarcoma (ES). Resection of the ilium and iliosacral joint causes pelvic disruption. However, the outcomes of resection and reconstruction are not well described. In this study, we report patients’ outcomes after resection of the ilium and iliosacral ES and reconstruction with a tibial strut allograft.

Methods

Medical files of 43 patients with ilium and iliosacral ES who underwent surgical resection and reconstruction with a tibial strut allograft between January 2010 and October 2021 were reviewed. The lesions were classified into four resection zones: I1, I2, I3, and I4, based on the extent of resection. Functional outcomes, oncological outcomes, and surgical complications for each resection zone were of interest. Functional outcomes were assessed using a Musculoskeletal Tumor Society (MSTS) score and Toronto Extremity Salvage Score (TESS).


Bone & Joint 360
Vol. 11, Issue 2 | Pages 27 - 30
1 Apr 2022


Bone & Joint Research
Vol. 11, Issue 2 | Pages 102 - 111
1 Feb 2022
Jung C Cha Y Yoon HS Park CH Yoo J Kim J Jeon Y

Aims

In this study, we aimed to explore surgical variations in the Femoral Neck System (FNS) used for stable fixation of Pauwels type III femoral neck fractures.

Methods

Finite element models were established with surgical variations in the distance between the implant tip and subchondral bone, the gap between the plate and lateral femoral cortex, and inferior implant positioning. The models were subjected to physiological load.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 969 - 971
1 Nov 1997
Baumgaertner MR Solberg BD

We compared the results of the surgical treatment of trochanteric hip fractures before and after surgeons had been introduced to the tip-apex distance (TAD) as a method of evaluating screw position. There were 198 fractures evaluated retrospectively and 118 after instruction. The TAD is the sum of the distance from the tip of the screw to the apex of the femoral head on antero-posterior and lateral views. This decreased from a mean of 25 mm in the control group to 20 mm in the study group (p = 0.0001). The number of mechanical failures by cut-out of the screw from the head decreased from 16 (8%) in the control group at a mean of 13 months to none in the study group at a mean of eight months (p = 0.0015). There were significantly fewer poor reductions in the study group. Our study confirms the importance of good surgical technique in the treatment of trochanteric fractures and supports the concept of the TAD as a clinically useful way of describing the position of the screw


Bone & Joint 360
Vol. 9, Issue 3 | Pages 31 - 34
1 Jun 2020


Bone & Joint Research
Vol. 9, Issue 10 | Pages 653 - 666
7 Oct 2020
Li W Li G Chen W Cong L

Aims

The aim of this study was to systematically compare the safety and accuracy of robot-assisted (RA) technique with conventional freehand with/without fluoroscopy-assisted (CT) pedicle screw insertion for spine disease.

Methods

A systematic search was performed on PubMed, EMBASE, the Cochrane Library, MEDLINE, China National Knowledge Infrastructure (CNKI), and WANFANG for randomized controlled trials (RCTs) that investigated the safety and accuracy of RA compared with conventional freehand with/without fluoroscopy-assisted pedicle screw insertion for spine disease from 2012 to 2019. This meta-analysis used Mantel-Haenszel or inverse variance method with mixed-effects model for heterogeneity, calculating the odds ratio (OR), mean difference (MD), standardized mean difference (SMD), and 95% confidence intervals (CIs). The results of heterogeneity, subgroup analysis, and risk of bias were analyzed.


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1629 - 1635
1 Dec 2020
Wang Q Sheng N Rui B Chen Y

Aims

The aim of this study was to explore why some calcar screws are malpositioned when a proximal humeral fracture is treated by internal fixation with a locking plate, and to identify risk factors for this phenomenon. Some suggestions can be made of ways to avoid this error.

Methods

We retrospectively identified all proximal humeral fractures treated in our institution between October 2016 and October 2018 using the hospital information system. The patients’ medical and radiological data were collected, and we divided potential risk factors into two groups: preoperative factors and intraoperative factors. Preoperative factors included age, sex, height, weight, body mass index, proximal humeral bone mineral density, type of fracture, the condition of the medial hinge, and medial metaphyseal head extension. Intraoperative factors included the grade of surgeon, neck-shaft angle after reduction, humeral head height, restoration of medial support, and quality of reduction. Adjusted binary logistic regression and multivariate logistic regression models were used to identify pre- and intraoperative risk factors. Area under the curve (AUC) analysis was used to evaluate the discriminative ability of the multivariable model.


Bone & Joint 360
Vol. 9, Issue 6 | Pages 5 - 11
1 Dec 2020
Sharma V Turmezei T Wain J McNamara I