Aims. In our unit, we adopt a two-stage surgical reconstruction approach using
Aims. In contrast to operations performed for other fractures, there is a high incidence rate of surgical site infection (SSI) post-open reduction and
Aims. Lower limb fractures are common in low- and middle-income countries (LMICs) and represent a significant burden to the existing orthopaedic surgical infrastructure. In high income country (HIC) settings,
We report a prospective single-blind controlled
study of the incidence of early wound infection after
Objectives. The aim of this study was to compare the biomechanical stability and clinical outcome of external fixator combined with limited
A consecutive series of 320 patients with an
intracapsular fracture of the hip treated with a dynamic locking
plate (Targon Femoral Neck (TFN)) were reviewed. All surviving patients
were followed for a minimum of two years. During the follow-up period
109 patients died. There were 112 undisplaced fractures, of which three (2.7%) developed
nonunion or re-displacement and five (4.5%) developed avascular
necrosis of the femoral head. Revision to an arthroplasty was required
for five patients (4.5%). A further six patients (5.4%) had elective
removal of the plate and screws. There were 208 displaced fractures, of which 32 (15.4%) developed
nonunion or re-displacement and 23 (11.1%) developed avascular necrosis.
A further four patients (1.9%) developed a secondary fracture around
the TFN. Revision to a hip replacement was required for 43 patients
(20.7%) patients and a further seven (3.3%) had elective removal
of the plate and screws. It is suggested that the stronger distal fixation combined with
rotational stability may lead to a reduced incidence of complications
related to the healing of the fracture when compared with other
contemporary fixation devices but this needs to be confirmed in
further studies. Cite this article:
The objective of this study was to investigate bone healing after
internal fixation of displaced femoral neck fractures (FNFs) with
the Dynamic Locking Blade Plate (DLBP) in a young patient population
treated by various orthopaedic (trauma) surgeons. We present a multicentre prospective case series with a follow-up
of one year. All patients aged ≤ 60 years with a displaced FNF treated
with the DLBP between 1st August 2010 and December 2014 were included.
Patients with pathological fractures, concomitant fractures of the
lower limb, symptomatic arthritis, local infection or inflammation,
inadequate local tissue coverage, or any mental or neuromuscular
disorder were excluded. Primary outcome measure was failure in fracture
healing due to nonunion, avascular necrosis, or implant failure
requiring revision surgery.Aims
Patients and Methods
We compared a new fixation system, the Targon
Femoral Neck (TFN) hip screw, with the current standard treatment of
cannulated screw fixation. This was a single-centre, participant-blinded,
randomised controlled trial. Patients aged 65 years and over with
either a displaced or undisplaced intracapsular fracture of the
hip were eligible. The primary outcome was the risk of revision
surgery within one year of fixation. A total of 174 participants were included in the trial. The absolute
reduction in risk of revision was of 4.7% (95% CI 14.2 to 22.5)
in favour of the TFN hip screw (chi-squared test, p = 0.741), which
was less than the pre-specified level of minimum clinically important
difference. There were no significant differences in any of the
secondary outcome measures. We found no evidence of a clinical difference in the risk of
revision surgery between the TFN hip screw and cannulated screw
fixation for patients with an intracapsular fracture of the hip. Cite this article:
The results of meta-analysis show a revision rate of 33% for
Aims. Monocyte-lymphocyte ratio (MLR) or neutrophil-lymphocyte ratio (NLR) are useful for diagnosing periprosthetic joint infection (PJI), but their diagnostic values are unclear for screening fixation-related infection (FRI) in patients for whom conversion total hip arthroplasty (THA) is planned after failed
Aims. The aim of this study was to describe the technique of distraction
osteogenesis followed by arthrodesis using
Failed
1. Eighty consecutive open fractures of the tibial shaft were treated by primary
Aims. Displaced, comminuted acetabular fractures in the elderly are increasingly common, but there is no consensus on whether they should be treated non-surgically, surgically with open reduction and
We compared the reoperation rate after
1. The results of
We studied 60 patients with an acute displaced fracture of the femoral neck and with a mean age of 84 years. They were randomly allocated to treatment by either
A total of 455 patients aged over 70 years with a displaced intracapsular fracture of the proximal femur was randomised to be treated either by hemiarthroplasty or
Two hundred and thirty-two ankle fractures were treated in the orthopaedic department of the Royal Portsmouth Hospital between 1959 and 1960. Seventy-one fractures treated by
In a series of 450 patients over 70 years of age with displaced fractures of the femoral neck sustained between 1995 and 1997 treatment was randomised either to
Over a seven-year period we treated a consecutive series of 58 patients, 20 men and 38 women with a mean age of 66 years (21 to 87) who had an acute complex anterior fracture-dislocation of the proximal humerus. Two patterns of injury are proposed for study based upon a prospective assessment of the pattern of soft-tissue and bony injury and the degree of devascularisation of the humeral head. In 23 patients, the head had retained capsular attachments and arterial back-bleeding (type-I injury), whereas in 35 patients the head was devoid of significant soft-tissue attachments with no active arterial bleeding (type-II injury). Following treatment by open reduction and
The operative treatment of displaced fractures of the tibial plateau is challenging. Recent developments in the techniques of
The treatment of infected exposed implants which have been used for
The place of
1. The results in 211 fractures of the shaft of the femur in adults treated by
We treated 34 consecutive articular fractures of the proximal humerus in 33 patients with good bone quality by open reduction and
The aim of this study was to review the number of patients operated on for traumatic disruption of the pubic symphysis who developed radiological signs of movement of the anterior pelvic metalwork during the first post-operative year, and to determine whether this had clinical implications. A consecutive series of 49 patients undergoing
1. A method of
We report three cases of avulsion of the ischial tuberosity with marked chronic disability after delay in diagnosis and non-union of the fracture. All were treated by open reduction and
Aims. We report the long-term outcomes of the UK Heel Fracture Trial (HeFT), a pragmatic, multicentre, two-arm, assessor-blinded, randomized controlled trial. Methods. HeFT recruited 151 patients aged over 16 years with closed displaced, intra-articular fractures of the calcaneus. Patients with significant deformity causing fibular impingement, peripheral vascular disease, or other significant limb injuries were excluded. Participants were randomly allocated to open reduction and
We describe a series of 20 patients with ununited fractures of the femoral neck following neglected trauma or failed primary
We describe a method of
It remains a matter of debate whether displaced fractures of the neck of the femur should be treated by
We investigated the clinical outcome of internal
fixation for pathological fracture of the femur after primary excision of
a soft-tissue sarcoma that had been treated with adjuvant radiotherapy. A review of our database identified 22 radiation-induced fractures
of the femur in 22 patients (seven men, 15 women). We noted the
mechanism of injury, fracture pattern and any complications after
internal fixation, including nonunion, hardware failure, secondary
fracture or deep infection. The mean age of the patients at primary excision of the tumour
was 58.3 years (39 to 86). The mean time from primary excision to
fracture was 73.2 months (2 to 195). The mean follow-up after fracture
fixation was 65.9 months (12 to 205). Complications occurred in
19 patients (86%). Nonunion developed in 18 patients (82%), of whom
11 had a radiological nonunion at 12 months, five a nonunion and
hardware failure and two an infected nonunion. One patient developed
a second radiation-associated fracture of the femur after internal
fixation and union of the initial fracture. A total of 13 patients
(59%) underwent 24 revision operations.
Fractures of the distal end of the radius should be treated on the same principles as other fractures involving joints. Displaced articular fractures require open reduction to allow anatomical reconstruction of both the radiocarpal and the radio-ulnar joints. For extra-articular fractures with severe comminution and shortening this enables the radial length to be re-established achieving radio-ulnar congruency. Stable
A total of 179 adult patients with displaced intra-articular fractures of the distal radius was randomised to receive indirect percutaneous reduction and external fixation (n = 88) or open reduction and
Our study describes a posterolateral approach to the distal humerus for open reduction and
1. This paper presents a series of 135 patients with displaced ankle fractures treated by rigid
Cadaveric experiments in 10 knees were used to study the strength of two methods of
A prospective randomised trial of surgical treatment for the displaced subcapital femoral fracture in patients of 70 years or more is presented. Two hundred and eighteen patients were randomly allocated into one of three treatment groups: manipulative reduction and
This study identified variables which influence the outcome of surgical management on 126 ununited scaphoid fractures managed by
1. The use of metallic
We used single-photon absorptiometry to assess the forearm bones after the removal of
In a prospective randomised study, the Hansson pin technique for
We have compared the results and complications after closed and open reduction with
Fifty-six patients with ununited intracapsular fractures of the femoral neck were treated by
Fifty-six patients with displaced malleolar fractures had open reduction and fixation of the fracture fragments using, by random selection, either biodegradable implants or metal AO plates and screws. The cylindrical biodegradable implants were made of polylactide-glycolide copolymer (polyglactin 910). The complications, radiographic results and functional recovery were studied prospectively. After follow-up of at least one year, no significant differences emerged in the complication rate or in the results of treatment between the two methods of fixation. Because of the advantage of avoiding the need to remove metal fixation after union, we now use biodegradable
It seems right to draw the following conclusions from this study of the relative merits of early and delayed fixation for fractures of the femoral and tibial shafts. 1. In patients under the age of sixty years with femoral shaft fractures there seems to be a significant improvement in the speed and quality of union when
We reviewed the records and radiographs from 10 hospitals to identify 50 patients with rheumatoid arthritis (RA) who had sustained 52 femoral neck fractures. Most patients were female (88%), elderly (mean age 66 years) and had had severe polyarticular disease for a mean duration of 16 years. Over half had taken systemic corticosteroids, nearly all were severely osteopenic but few had rheumatoid changes in the hip. Of the 20 fractures treated by
In 42 elderly patients, 33 women and nine men with a mean age of 72 years, we treated displaced fractures of the proximal humerus (34 three-part, 8 four-part) using a blade plate and a standard deltopectoral approach. Functional treatment was started immediately after surgery. We reviewed 41 patients at one year and 38 at final follow-up at 3.4 years (2.4 to 4.5). At the final review, all the fractures had healed. The clinical results were graded as excellent in 13 patients, good in 17, fair in seven, and poor in one. The median Constant score was 73 ± 18. Avascular necrosis of the humeral head occurred in two patients (5%). We conclude that rigid fixation of displaced fractures of the proximal humerus with a blade plate in the elderly patient provides sufficient primary stability to allow early functional treatment. The incidence of avascular necrosis and nonunion was low. Restoration of the anatomy and biomechanics may contribute to a good functional outcome when compared with alternative methods of fixation or conservative treatment. Regardless of the age of the patients, we advocate primary open reduction and rigid
Three cases of anterior interosseous nerve palsy were diagnosed after
One hundred patients who had sustained a fracture of the tibial shaft and had been treated by
We investigated whether patients who underwent
The treatment algorithms for displaced fractures of the femoral neck need to be improved if we are to reduce the need for secondary surgery. We have studied 102 patients of mean age 80 years, with an acute displaced fracture of the femoral neck. They were randomly placed into two groups, treated either by
We reviewed 57 adult patients at an average of 37 months after early
We used calcium-phosphate cement combined with minimal
1. A report is presented of the results of a trial to compare the effects of early and late weight-bearing in patients with a transcervical fracture of the femur treated by reduction of the fracture and
We reviewed 24 displaced fractures through the physis of the medial epicondyle of the distal humerus. One was a Salter-Harris type-II fracture-separation of the whole distal humeral epiphysis; the others involved only the medial epicondylar centre of ossification. Two cases had presented as pseudarthroses. One fracture had been treated closed in a plaster slab and 21 had had open reduction and
1 . A preliminary report is presented of a clinical trial to compare the results of early and late weight bearing in randomly selected patients of comparable age groups whose displaced femoral neck fractures were treated by
We have reviewed 402 traumatic fractures of the femoral shaft, 320 of which had been treated by operation and had a long follow-up. Of these, 228 closed fractures and 37 open fractures had been stabilised by plating. There was no significant difference in healing between those stabilised early and those having delayed
Ankle fracture fixation is commonly performed by junior trainees. Simulation training using cadavers may shorten the learning curve and result in a technically superior surgical performance. We undertook a preliminary, pragmatic, single-blinded, multicentre, randomized controlled trial of cadaveric simulation versus standard training. Primary outcome was fracture reduction on postoperative radiographs.Aims
Methods
Ulnar nerve function, during and after open reduction and
The aim of this study was to systematically compare the safety and accuracy of robot-assisted (RA) technique with conventional freehand with/without fluoroscopy-assisted (CT) pedicle screw insertion for spine disease. A systematic search was performed on PubMed, EMBASE, the Cochrane Library, MEDLINE, China National Knowledge Infrastructure (CNKI), and WANFANG for randomized controlled trials (RCTs) that investigated the safety and accuracy of RA compared with conventional freehand with/without fluoroscopy-assisted pedicle screw insertion for spine disease from 2012 to 2019. This meta-analysis used Mantel-Haenszel or inverse variance method with mixed-effects model for heterogeneity, calculating the odds ratio (OR), mean difference (MD), standardized mean difference (SMD), and 95% confidence intervals (CIs). The results of heterogeneity, subgroup analysis, and risk of bias were analyzed.Aims
Methods
Aims. Pneumatic tourniquets are often used during the surgical treatment of unstable traumatic ankle fractures. The aim of this study was to assess the risk of reoperation after open reduction and
A total of 11 patients (12 knees) with stable lesions of osteochondritis dissecans of the knee underwent arthroscopic fixation of the fragments using polylactide bioabsorbable pins. The site of the lesion was the medial femoral condyle in ten knees and the lateral femoral condyle in two. The mean age of the patients was 14.8 years (12 to 16). At a mean follow-up of 32.4 months (13 to 38 months) all fragments had MRI evidence of union. One patient developed early transient synovitis, which resolved with non-steroidal anti-inflammatory medication. All patients returned to sporting activities within eight months of operation and did not require a period of immobilisation.
Despite being one of the most common injuries around the elbow, the optimal treatment of olecranon fractures is far from established and stimulates debate among both general orthopaedic trauma surgeons and upper limb specialists. It is almost universally accepted that stable non-displaced fractures can be safely treated nonoperatively with minimal specialist input.
Aims. This study aimed to evaluate the effectiveness of the induced membrane technique for treating infected bone defects, and to explore the factors that might affect patient outcomes. Methods. A comprehensive search was performed in PubMed, Embase, and the Cochrane Central Register of Controlled Trials databases between 1 January 2000 and 31 October 2021. Studies with a minimum sample size of five patients with infected bone defects treated with the induced membrane technique were included. Factors associated with nonunion, infection recurrence, and additional procedures were identified using logistic regression analysis on individual patient data. Results. After the screening, 44 studies were included with 1,079 patients and 1,083 segments of infected bone defects treated with the induced membrane technique. The mean defect size was 6.8 cm (0.5 to 30). After the index second stage procedure, 85% (797/942) of segments achieved union, and 92% (999/1,083) of segments achieved final healing. The multivariate analysis with data from 296 patients suggested that older age was associated with higher nonunion risk. Patients with external fixation in the second stage had a significantly higher risk of developing nonunion, increasing the need for additional procedures. The autografts harvested from the femur reamer-irrigator-aspirator increased nonunion, infection recurrence, and additional procedure rates. Conclusion. The induced membrane technique is an effective technique for treating infected bone defects.
Aims. Our primary aim was to assess reoperation-free survival at one year after the index injury in patients aged ≥ 75 years treated with
Tibial plateau fractures are serious injuries about the knee that have the potential to affect patients’ long-term function. To our knowledge, this is the first study to use patient-reported outcomes (PROs) with a musculoskeletal focus to assess the long-term outcome, as compared to a short-term outcome baseline, of tibial plateau fractures treated using modern techniques. In total, 102 patients who sustained a displaced tibial plateau fracture and underwent operative repair by one of three orthopaedic traumatologists at a large, academic medical centre and had a minimum of five-year follow-up were identified. Breakdown of patients by Schatzker classification is as follows: two (1.9%) Schatzker I, 54 (50.9%) Schatzker II, two (1.9%) Schatzker III, 13 (12.3%) Schatzker IV, nine (8.5%) Schatzker V, and 26 (24.5%) Schatzker VI. Follow-up data obtained included: Visual Analogue Scale (VAS) or Numeric Rating Scale (NRS) pain scores, Short Musculoskeletal Functional Assessment (SMFA), and knee range of movement (ROM). Data at latest follow-up were then compared to 12-month data using a paired Aims
Methods
The optimal management of intracapsular fractures of the femoral
neck in independently mobile patients remains open to debate. Successful
fixation obviates the limitations of arthroplasty for this group
of patients. However, with fixation failure rates as high as 30%,
the outcome of revision surgery to salvage total hip arthroplasty
(THA) must be considered. We carried out a systematic review to
compare the outcomes of salvage THA and primary THA for intracapsular
fractures of the femoral neck. We performed a Preferred Reporting Items for Systematic Reviews
and Meta-Analysis (PRISMA) compliant systematic review, using the
PubMed, EMBASE and Cochrane libraries databases. A meta-analysis
was performed where possible, and a narrative synthesis when a meta-analysis
was not possible.Aims
Patients and Methods
Aims. Surgical approaches to cervical ossification of the posterior longitudinal ligament (OPLL) remain controversial. The purpose of the present study was to analyze and compare the long-term neurological recovery following anterior decompression with fusion (ADF) and posterior laminectomy and fusion with bone graft and
This report describes a technique for the correction and fusion of scoliosis with the aid of a flexible metal rod that is fixed by wires under tension to the bases of the spinous processes on the convex side of the curve at a number of points. The results in a series of 100 cases are reported. In the last seventy patients, the average correction at one month was 51 per cent, and after two years 45 per cent. In these seventy cases the incidence of pseudarthrosis was 5-7 per cent.
The extended lateral L-shaped approach for the treatment of displaced intra-articular fractures of the calcaneum may be complicated by wound infection, haematoma, dehiscence and injury to the sural nerve. In an effort to reduce the risk of problems with wound healing a technique was developed that combined open reduction and fixation of the joint fragments and of the anterior process with percutaneous reduction and screw fixation of the tuberosity. A group of 24 patients with unilateral isolated closed Sanders type II and III fractures was treated using this technique and compared to a similar group of 26 patients managed by the extended approach and lateral plating. The operation was significantly shorter (p <
0.001) in the first group, but more minor secondary procedures and removal of heel screws were necessary. There were no wound complications in this group, whereas four minor complications occurred in the second group. The accuracy and maintenance of reduction, and ultimate function were equivalent.
The primary aim of this study was to determine if delayed clavicular fixation results in a greater risk of operative complications and revision surgery. A retrospective case series was undertaken of all displaced clavicular fractures that underwent plate fixation over a ten-year period (2007 to 2017). Patient demographics, time to surgery, complications, and mode of failure were collected. Logistic regression was used to identify independent risk factors contributing towards operative complications. Receiver operating characteristic (ROC) curve analysis was used to determine if a potential ‘safe window’ exists from injury to delayed surgery. Propensity score matching was used to construct a case control study for comparison of risk.Aims
Patients and Methods
We reviewed a series of 79 distal radial fractures with volar displacement which had been fixed internally using a buttress plate. The fractures were classified using the Frykman and AO systems; 59% were intraarticular. Complications occurred in 40.5% of cases; malunion was most frequent (28%). Functional recovery in patients with malunion was significantly worse than in those with good anatomical restoration (p <
0.001). The AO and Frykman classifications and the degree of restoration of volar tilt were predictive of outcome.
We describe a patient who sustained a displaced isolated intra-articular fracture of the distal ulna, causing limitation of rotation of the forearm. The extent of displacement of the fracture which was not evident on plain radiographs was revealed by CT. The fracture was reduced and internally fixed using a standard technique applicable to the fixation of fractures of the radial head. Full movement was restored. An isolated injury to the distal ulna is rare and requires careful clinical and radiological assessment.
In a prospective study we assessed the causes of mechanical failure in a series of 230 intertrochanteric femoral fractures which had been internally fixed with either a sliding hip screw or a Kuntscher Y-nail. The overall rate of mechanical failure was 16.5%; cutting-out of the implant from the femoral head was the cause in three-quarters of the instances. Implants placed posteriorly in the femoral head cut out more often (27%) than those placed centrally (7%). The cut-out rate was also determined by the quality of the fracture reduction, but age, walking ability and bone density (assessed by the Singh grade and metacarpal indices) had no significant influence. We conclude that these fractures should be reduced as accurately as possible and it is imperative that the implant is placed centrally within the femoral head.
A technique of subtalar arthrodesis by means of metallic internal stabilisation and autogenous cancellous bone grafting is described. Of forty-eight feet with mobile pes planus treated by this method forty-five gained union after an average of seven and a half weeks in a below-knee weight-bearing plaster, and forty-three had satisfactory correction of the deformity.
1. The probable greatest bending moment applied to a plated or nailed fracture of the tibia during restricted weight-bearing is estimated to be, in men, up to about 79 Newton metres (58 poundsforce feet). The maximum twisting moment is estimated to be about 29 Newton metres (22 poundsforce feet). 2. Twenty-two human tibiae were loaded in three-point bending and broke at bending moments of from 57·9 to 294 Newton metres (42·7 to 216 poundsforce feet) if they had not previously been drilled; tibiae which had holes made through both cortices with a c. 3-millimetre (⅛-inch) drill broke at from 32·4 to 144 Newton metres (23·8 to 106 poundsforce feet). Tibiae loaded in torsion broke at twisting moments of from 27·5 to 892 Newton metres (20·2 to 65·8 poundsforce feet) when not drilled, 23·6 to 77·5 Newton metres (l7·3 to 57·1 poundsforce feet) when drilled. 3. When bent so as to open the fracture site, the 14-centimetre Stamm was the strongest of all the single plates tested (reaching its elastic limit at a bending moment of 17·6 Newton metres (13 poundsforce feet) and 5 degrees total angulation at 22·6 Newton metres (16·6 poundsforce feet)), while the Venable was the weakest (elastic limit 4·9 Newton metres (3·6 poundsforce feet) and 5 degrees at 7·9 Newton metres (5·8 poundsforce feet)). A 13-millimetre Küntscher nail reached its elastic limit at 42·2 Newton metres (31·1 poundsforce feet) and 5 degrees total angulation at 49 Newton metres (36 poundsforce feet). 4. In torsion the 15-centimetre Hicks was the strongest ofthe plates (elastic limit 27·5 Newton metres (20·2 poundsforce feet) and 5 degrees rotation at 16·7 Newton metres (l2·3 poundsforce feet)). 5. Küntscher nails in bones provided no dependable strength in torsion. 6. In both bending and torsion, a preparation of one Venable plate on each of the two anterior surfaces was stronger than any single plate, and was as strong as the weaker drilled tibiae. 7. The three currently available metallic materials (stainless steel, cobalt-chrome and titanium) have static mechanical properties so similar that the choice between them can be made on other grounds. 8. The highest load applied to a screw during bending tests was about half that needed to pull a screw out of even a thin-walled tibia. 9. Screws beyond four for one plate are mechanically redundant at the moment of implantation but may be necessary as an insurance against subsequent deterioration in strength. 10. Countersinks in plates are a source of significant weakness, and should preferably be as shallow as possible. 11. An unoccupied screw hole in the centre of a plate is a source of serious weakness. 12. Only the strongest implants tested were strong enough to withstand the bending or twisting moments to be expected in restricted weight-bearing. In two-plate preparations a danger is introduced by the fact that these moments are similar to those required to Ireak a drilled tibia.
Aims. In UK there are around 76,000 hip fractures occur each year 10% to 15% of which are undisplaced intracapsular. There is considerable debate whether
The fundamental concept of open reduction and internal fixation
(ORIF) of ankle fractures has not changed appreciably since the
1960s and, whilst widely used, is associated with complications
including wound dehiscence and infection, prominent hardware and
failure. Closed reduction and intramedullary fixation (CRIF) using
a fibular nail, wires or screws is biomechanically stronger, requires
minimal incisions, and has low-profile hardware. We hypothesised
that fibular nailing in the elderly would have similar functional
outcomes to standard fixation, with a reduced rate of wound and
hardware problems. A total of 100 patients (25 men, 75 women) over the age of 65
years with unstable ankle fractures were randomised to undergo standard
ORIF or fibular nailing (11 men and 39 women in the ORIF group,
14 men and 36 women in the fibular nail group). The mean age was
74 years (65 to 93) and all patients had at least one medical comorbidity. Complications,
patient related outcome measures and cost-effectiveness were assessed
over 12 months.Aims
Patients and Methods
Stable fixation of fractures of the distal radius can be achieved by using two 2.0 mm titanium plates placed on the radial and intermediate columns angled 50° to 70° apart. We describe our results with this method in a prospective series of 74 fractures (58 severely comminuted) in 73 consecutive patients. Early postoperative mobilisation was possible in all except four wrists. All of the 73 patients, except two with other injuries, returned to work and daily activities with no limitations. The anatomical results were excellent or good in 72 patients and fair in one. Our discussion includes details of important technical considerations based on an analysis of the specific complications which were seen early in the series.
Neglected fractures of the femoral neck, common in young adults in underdeveloped countries, may be complicated by nonunion or avascular necrosis (AVN). We treated 52 cases by open reduction, fixation by compression screw and a free fibular graft. The mean delay between injury and operation was 5.1 months. Of 40 fractures assessed at a mean of 58.8 months (24 to 153), 38 were found to be united and two, owing to surgical errors, were not. Seven of eight heads which were avascular before operation revascularised without collapse, while seven others developed AVN after the procedure. At the last follow-up considerable collapse was apparent in five femoral heads, and 11 hips had developed coxa vara. The fibular graft had fractured in four cases. The hip had been penetrated by the screw in six cases and by the graft in three. Hip function was excellent in seven patients, good in 21 and fair in seven. Five patients had poor results. Incorporation of the fibular graft was seen after four years: in many cases the graft had been almost completely resorbed. We recommend this procedure for the treatment of neglected fractures of the neck of the femur in young adults to reduce resorption of the neck, AVN and nonunion.
We performed posterior fixation with a Hartshill-Ransford contoured loop in 43 patients with instability at the craniocervical junction. No external bracing was used. Fifteen patients had congenital malformations, ten had tumours, seven had 'bone-softening' conditions (such as osteogenesis imperfecta), five had suffered complicated fractures, three had occipito-C1-C2 hypermobility due to lax ligaments and three had severe degenerative spondylosis with pseudotumours of the transverse ligament. Twenty-nine patients had transoral decompression of the cord before fixation. In most cases, cancellous bone grafts taken from the iliac crest were used to induce fusion; in nine very ill patients, no bone graft was used. In the whole series there was no instance of construct failure, broken wire or laminar fracture. The best results were achieved in patients with tumours or bone-softening conditions. No patient with normal neurology deteriorated after surgery but seven had worse neurological deficits after operation than before. Neck stiffness caused half the patients to change their lifestyle.
We present the results of a prospective trial of osteotomy of the metatarsal neck for hallux valgus in 31 feet of 23 women, using a new stapling device with no plaster splintage and early weight-bearing. Surgery was performed for pain (29 feet) and difficulty with footwear (nine feet). The average time for return to light work was 3.3 weeks, and to full work 8.3 weeks after operation. Seventeen patients had full recovery within three months and 21 of the 23 patients had complete relief of pain. Shoes were more comfortable in 17 feet and 9 patients could wear narrower shoes. Only two patients were unsatisfied with the appearance of the foot. All the osteotomies united, and the average hallux valgus angle was improved on radiographs from 35 degrees to 23 degrees. The mean first metatarsal angle was reduced from 16 degrees to 11 degrees. The new technique allows more accurate surgery and easier postoperative management.
1. One hundred and eight osteotomies were reviewed with regard to union, and fourteen were found to be ununited. In only one was non-union detected clinically; the others required radiographic demonstration. Tomographs were particularly helpful in confirming non-union. 2. Nine patients with non-union had pain, equal to or worse than before operation. The pain could not be distinguished from that of osteoarthritis of the hip. 3. Six of the patients with non-union needed an operation. Five had cancellous bone grafts followed by union in all except one. 4. The causes of non-union are reviewed. This complication was found to be less frequent in patients above sixty with stiff hips and bony collapse on the radiograph. Horizontal osteotomy with a displacement of not more than one-third of the diameter of the shaft reduced the incidence of non-union. The variable-angle nail-plate provided the best fixation. Traction provided no benefit and increased the incidence of non-union. Weight bearing is best avoided for eight weeks.
Between 1996 and 2000, we treated ten patients with severely comminuted fractures of the radial head using low-profile mini-plates. Their mean age was 42 years (24 to 71). Three fractures were Mason type III and seven were Mason-Johnston type IV. At a mean follow-up of 28.5 months (15 to 44), all fractures had united. The plates were removed in nine patients. No patient had difficulty with daily activities or symptoms of instability of the elbow. The mean range of flexion of the elbow was from 7° to 135°, with 74° of supination and 85° of pronation. According to the Broberg and Morrey functional elbow index, the mean score was 90.7 points (73 to 100), and the outcome was excellent in three patients, good in six and fair in one. These results compare favourably with those reported previously. The technique is applicable to severely comminuted fractures of the radial head which otherwise would require excision.