We report the clinical and radiological outcomes
of a series of contemporary cementless ceramic-on-ceramic total hip
replacements (THRs) at ten years in patients aged ≤ 55 years of
age. Pre- and post-operative activity levels are described. A total
of 120 consecutive ceramic cementless THRs were performed at a single
centre in 110 patients from 1997 to 1999. The mean age of the patients
at operation was 45 years (20 to 55). At ten years, four patients
had died and six were lost to follow-up, comprising ten hips. The
mean post-operative Harris hip score was 94.7 (55 to 100). Radiological
analysis was undertaken in 90 available THRs of the surviving 106
hips at final review: all had evidence of stable bony ingrowth,
with no cases of osteolysis. Wear was undetectable. There were four
revisions. The survival for both components with revision for any
cause as an endpoint was 96.5% (95% confidence interval 94.5 to
98.7). The mean modified University of California, Los Angeles activity
level rose from a mean of 6.4 (4 to 10) pre-operatively to 9.0 (6
to 10) at the ten-year post-operative period. Alumina ceramic-on-ceramic bearings in cementless primary THR
in this series have resulted in good clinical and radiological outcomes
with undetectable rates of wear and excellent function in the demanding
younger patient group at ten years. Cite this article:
The aim of this study was to determine whether
an osteoplasty of the femoral neck performed at the same time as an
intertrochanteric Imhäuser osteotomy led to an improved functional
outcome or increased morbidity. A total of 20 hips in 19 patients
(12 left, 8 right, 13 male, 6 female), who underwent an Imhäuser
intertrochanteric osteotomy following a slipped capital femoral
epiphysis were assessed over an eight-year period. A total of 13
hips in 13 patients had an osteoplasty of the femoral neck at the
same time. The remaining six patients (seven hips) had intertrochanteric
osteotomy alone. The mean age was 15.3 years (13 to 20) with a mean
follow-up of 57.8 months (15 to 117); 19 of the slips were severe
(Southwick grade III) and one was moderate (grade II), with a mean
slip angle of 65.3° (50° to 80°); 17 of the slips were stable and
three unstable at initial presentation. The mean Non-Arthritic Hip Scores
(NAHS) in patients who underwent osteoplasty was 91.7 (76.3 to 100)
and the mean NAHS in patients who did not undergo osteoplasty was
76.6 (41.3 to 100) (p = 0.056). Two patients required a subsequent
arthroplasty and neither of these patients had an osteoplasty. No
hips developed osteonecrosis or chondrolysis, and there was no increase
in complications related to the osteoplasty. We recommend that for
patients with a slipped upper femoral epiphysis undergoing an intertrochanteric
osteotomy, the addition of an osteoplasty of the femoral neck should
be considered. Cite this article:
Electronic forms of data collection have gained interest in recent
years. In orthopaedics, little is known about patient preference
regarding pen-and-paper or electronic questionnaires. We aimed to
determine whether patients undergoing total hip (THR) or total knee
replacement (TKR) prefer pen-and-paper or electronic questionnaires
and to identify variables that predict preference for electronic
questionnaires. We asked patients who participated in a multi-centre cohort study
investigating improvement in health-related quality of life (HRQoL)
after THR and TKR using pen-and-paper questionnaires, which mode
of questionnaire they preferred. Patient age, gender, highest completed
level of schooling, body mass index (BMI), comorbidities, indication
for joint replacement and pre-operative HRQoL were compared between
the groups preferring different modes of questionnaire. We then
performed logistic regression analyses to investigate which variables
independently predicted preference of electronic questionnaires.Objectives
Methods
The October 2013 Trauma Roundup360 looks at: Radiological, electromagnetic or just leave it out altogether?: distal locking in intramedullary nailing; Internal fixation of radiation-induced pathological fractures of the femur has a high rate of failure; Obesity and trauma; Short and sweet?: antibiotics in open fractures; Extremity injuries more important than previously thought?; Cement nails tiptop for osteomyelitis; Oxygen measurements for compartment syndrome?
In this randomised controlled trial, we evaluated
the role of elastic compression using ankle injury stockings (AIS)
in the management of fractures of the ankle. A total of 90 patients
with a mean age of 47 years (16 to 79) were treated within 72 hours
of presentation with a fracture of the ankle, 31 of whom were treated
operatively and 59 conservatively, were randomised to be treated
either with compression by AIS plus an Aircast boot or Tubigrip
plus an Aircast boot. Male to female ratio was 36:54. The primary
outcome measure was the functional Olerud–Molander ankle score (OMAS).
The secondary outcome measures were; the American Orthopaedic Foot
and Ankle Society score (AOFAS); the Short Form (SF)-12v2 Quality
of Life score; and the frequency of deep vein thrombosis (DVT). Compression using AIS reduced swelling of the ankle at all time
points and improved the mean OMAS score at six months to 98 (95%
confidence interval (CI) 96 to 99) compared with a mean of 67 (95%
CI 62 to 73) for the Tubigrip group (p <
0.001). The mean AOFAS
and SF-12v2 scores at six months were also significantly improved
by compression. Of 86 patients with duplex imaging at four weeks,
five (12%) of 43 in the AIS group and ten (23%) of 43 in the Tubigrip
group developed a DVT (p = 0.26). Compression improved functional outcome and quality of life following
fracture of the ankle. DVTs were frequent, but a larger study would
be needed to confirm that compression with AISs reduces the incidence
of DVT. Cite this article:
The June 2014 Shoulder &
Elbow Roundup360 looks at: suprascapular nerve and rotator cuff pathology; anchors in Bankart repair: it’s not what you’ve got, but how you use it; not all shoulder PROMs are equal; reverse shoulder arthroplasty OK in trauma; not all in the mind: frozen shoulder personality debunked; open and arthroscopic repair equivalent in shoulder instability; natural history of olecranon fractures not so bleak?; and resurfacing of the shoulder: a Danish perspective.
Pre-operative variables are increasingly being
used to determine eligibility for total knee replacement (TKR).
This study was undertaken to evaluate the relationships, interactions
and predictive capacity of variables available pre- and post-operatively
on patient satisfaction following TKR. Using nationally collected
patient reported outcome measures and data from the National Joint
Registry for England and Wales, we identified
22 798 patients who underwent TKR for osteoarthritis between August
2008 and September 2010. The ability of specific covariates to predict
satisfaction was assessed using ordinal logistic regression and
structural equational modelling. Only 4959 (22%) of 22 278 patients
rated the results of their TKR as ‘excellent’, despite the majority
(71%, n = 15 882) perceiving their knee symptoms to be much improved.
The strongest predictors of satisfaction were post-operative variables.
Satisfaction was significantly and positively related to the perception
of symptom improvement (operative success) and the post-operative
EuroQol-5D score. While also significant within the models pre-operative
variables were less important and had a minimal influence upon post-operative
satisfaction. The most robust predictions of satisfaction occurred
only when both pre- and post-operative variables were considered
together. These findings question the appropriateness of restricting
access to care based on arbitrary pre-operative thresholds as these
factors have little bearing on post-operative satisfaction. Cite this article:
A clinical investigation into a new bone void filler is giving
first data on systemic and local exposure to the anti-infective
substance after implantation. A total of 20 patients with post-traumatic/post-operative bone
infections were enrolled in this open-label, prospective study.
After radical surgical debridement, the bone cavity was filled with
this material. The 21-day hospitalisation phase included determination
of gentamicin concentrations in plasma, urine and wound exudate, assessment
of wound healing, infection parameters, implant resorption, laboratory
parameters, and adverse event monitoring. The follow-up period was
six months. Objective
Method
Intravenous tranexamic acid (TXA) has been shown
to be effective in reducing blood loss and the need for transfusion
after joint replacement. Recently, there has been interest in applying
it topically before the closure of surgical wounds. This has the
advantages of ease of application, maximum concentration at the
site of bleeding, minimising its systemic absorption and, consequently,
concerns about possible side-effects. We conducted a systematic review and meta-analysis which included
14 randomised controlled trials (11 in knee replacement, two in
hip replacement and one in both) which investigated the effect of
topical TXA on blood loss and rates of transfusion. Topical TXA
significantly reduced the rate of blood transfusion (total knee
replacement: risk ratio (RR) 4.51; 95% confidence interval (CI):
3.02 to 6.72; p <
0.001 (nine trials, I2 = 0%); total
hip replacement: RR 2.56; 95% CI: 1.32 to 4.97, p = 0.004 (one trial)).
The rate of thromboembolic events with topical TXA were similar
to those found with a placebo. Indirect comparison of placebo-controlled
trials of topical and intravenous TXA indicates that topical administration
is superior to the intravenous route. In conclusion, topical TXA is an effective and safe method of
reducing the need for blood transfusion after total knee and hip
replacement. Further research is required to find its optimum dose
for topical use. Cite this article:
Correct positioning and alignment of components during primary total knee replacement (TKR) is widely accepted to be an important predictor of patient satisfaction and implant durability. This retrospective study reports the effect of the post-operative mechanical axis of the lower limb in the coronal plane on implant survival following primary TKR. A total of 501 TKRs in 396 patients were divided into an aligned group with a neutral mechanical axis (± 3°) and a malaligned group where the mechanical axis deviated from neutral by >
3°. At 15 years’ follow-up, 33 of 458 (7.2%) TKRs were revised for aseptic loosening. Kaplan-Meier survival analysis showed a weak tendency towards improved survival with restoration of a neutral mechanical axis, but this did not reach statistical significance (p = 0.47). We found that the relationship between survival of a primary TKR and mechanical axis alignment is weaker than that described in a number of previous reports.
We report our experience of revision total hip
replacement (THR) using the Revitan curved modular titanium fluted revision
stem in patients with a full spectrum of proximal femoral defects.
A total of 112 patients (116 revisions) with a mean age of 73.4
years (39 to 90) were included in the study. The mean follow-up
was 7.5 years (5.3 to 9.1). A total of 12 patients (12 hips) died
but their data were included in the survival analysis, and four
patients (4 hips) were lost to follow-up. The clinical outcome,
proximal bone regeneration and subsidence were assessed for 101
hips. The mean Harris Hip Score was 88.2 (45.8 to 100) after five years
and there was an increase of the mean Barnett and Nordin-Score,
a measure of the proximal bone regeneration, of 20.8 (-3.1 to 52.7).
Five stems had to be revised (4.3%), three (2.9%) showed subsidence,
five (4.3%) a dislocation and two of 85 aseptic revisions (2.3%)
a periprosthetic infection. At the latest follow-up, the survival with revision of the stem
as the endpoint was 95.7% (95% confidence interval 91.9% to 99.4%)
and with aseptic loosening as the endpoint, was 100%. Peri-prosthetic
fractures were not observed. We report excellent results with respect to subsidence, the risk
of fracture, and loosening after femoral revision using a modular
curved revision stem with distal cone-in-cone fixation. A successful
outcome depends on careful pre-operative planning and the use of
a transfemoral approach when the anatomy is distorted or a fracture
is imminent, or residual cement or a partially-secured existing
stem cannot be removed. The shortest appropriate stem should, in
our opinion, be used and secured with >
3 cm fixation at the femoral
isthmus, and distal interlocking screws should be used for additional
stability when this goal cannot be realised. Cite this article:
This review is aimed at clinicians appraising
preclinical trauma studies and researchers investigating compromised bone
healing or novel treatments for fractures. It categorises the clinical
scenarios of poor healing of fractures and attempts to match them
with the appropriate animal models in the literature. We performed an extensive literature search of animal models
of long bone fracture repair/nonunion and grouped the resulting
studies according to the clinical scenario they were attempting
to reflect; we then scrutinised them for their reliability and accuracy
in reproducing that clinical scenario. Models for normal fracture repair (primary and secondary), delayed
union, nonunion (atrophic and hypertrophic), segmental defects and
fractures at risk of impaired healing were identified. Their accuracy
in reflecting the clinical scenario ranged greatly and the reliability
of reproducing the scenario ranged from 100% to 40%. It is vital to know the limitations and success of each model
when considering its application.
The outcome of an anatomical shoulder replacement
depends on an intact rotator cuff. In 1981 Grammont designed a novel
large-head reverse shoulder replacement for patients with cuff deficiency.
Such has been the success of this replacement that it has led to
a rapid expansion of the indications. We performed a systematic
review of the literature to evaluate the functional outcome of each
indication for the reverse shoulder replacement. Secondary outcome
measures of range of movement, pain scores and complication rates
are also presented.
Metal-on-metal (MoM) hip resurfacing was developed in the 1990s by surgeons in Birmingham, UK, as a surgical solution to the problem of osteoarthritis in younger, more active patients. Early results were promising and the procedure gained in popularity. However, adverse reports of soft-tissue reaction and failure started to appear from 2008 onwards. Surgeons may be asked to write medico-legal reports on the surgical aspects of an individual case for claimant lawyers or in defence for the NHSLA or indemnity insurers. The purpose of this article is to cover some of the aspects of the operation that may be considered in such medico-legal reports.
The June 2012 Hip &
Pelvis Roundup360 looks at: whether metal-on-metal is really such a disaster; resurfacings with unexplained pain; large heads and high ion levels; hip arthroscopy for FAI; the inaccuracy of clinical tests for impingement; arthroscopic lengthening of iliopsoas; the OA hip; the injured hamstring – football’s most common injury; an algorithm for hip fracture surgery; and sparing piriformis at THR.
The treatment of substantial proximal femoral
bone loss in young patients with developmental dysplasia of the
hip (DDH) is challenging. We retrospectively analysed the outcome
of 28 patients (30 hips) with DDH who underwent revision total hip
replacement (THR) in the presence of a deficient proximal femur,
which was reconstructed with an allograft prosthetic composite.
The mean follow-up was 15 years (8.5 to 25.5). The mean number of
previous THRs was three (1 to 8). The mean age at primary THR and
at the index reconstruction was 41 years (18 to 61) and 58.1 years
(32 to 72), respectively. The indication for revision included mechanical
loosening in 24 hips, infection in three and peri-prosthetic fracture
in three. Six patients required removal and replacement of the allograft
prosthetic composite, five for mechanical loosening and one for
infection. The survivorship at ten, 15 and 20 years was 93% (95%
confidence interval (CI) 91 to 100), 75.5% (95% CI 60 to 95) and
75.5% (95% CI 60 to 95), respectively, with 25, eight, and four
patients at risk, respectively. Additionally, two junctional nonunions
between the allograft and host femur required bone grafting and
plating. An allograft prosthetic composite affords a good long-term outcome
in the management of proximal femoral bone loss in revision THR
in patients with DDH, while preserving distal host bone.
In 1999, we developed a technique for biological
reconstruction after excision of a bone tumour, which involved using
autografts of the bone containing the tumour treated with liquid
nitrogen. We have previously reported the use of this technique
in 28 patients at a mean follow up of 27 months (10 to 54). In this study, we included 72 patients who underwent reconstruction
using this technique. A total of 33 patients died and three were
lost to follow-up, at a mean of 23 months (2 to 56) post-operatively,
leaving 36 patients available for a assessment at a mean of 101
months 16 to 163) post-operatively. The methods of reconstruction included
an osteo-articular graft in 16, an intercalary in 13 and, a composite
graft with prosthesis in seven. Post-operative function was excellent in 26 patients (72.2%),
good in seven (19.4%), and fair in three (8.3%) according to the
functional evaluation system of Enneking. No recurrent tumour occurred
within the grafts. The autografts survived in 29 patients (80.6%),
and the rates of survival at five and ten years were 86.1% and 80.6
%, respectively. Seven of 16 osteo-articular grafts (44%) failed
because of fracture or infection, but all the composite and intercalary
grafts survived. The long-term outcomes of frozen autografting, particularly using
composite and intercalary grafts, are satisfactory and thus represent
a good method of treatment for patients with a sarcoma of bone or
soft tissue. Cite this article:
Current analysis of unicondylar knee replacements
(UKRs) by national registries is based on the pooled results of medial
and lateral implants. Consequently, little is known about the differential
performance of medial and lateral replacements and the influence
of each implant type within these pooled analyses. Using data from
the National Joint Registry for England and Wales (NJR) we aimed
to determine the proportion of UKRs implanted on the lateral side
of the knee, and their survival and reason for failure compared
with medial UKRs. By combining information on the side of operation
with component details held on the NJR, we were able to determine
implant laterality (medial