Advertisement for orthosearch.org.uk
Results 1781 - 1800 of 2262
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 639 - 643
1 May 2011
Burghardt RD Herzenberg JE Specht SC Paley D

Between October 2001 and September 2009 we lengthened 242 lower-limb segments in 180 patients using the Intramedullary Skeletal Kinetic Distractor (ISKD). Mechanical failure was defined either as breakage of the ISKD or failure of the internal mechanism to activate. Retrieved nails which failed mechanically were examined by the manufacturer for defects. In all, 15 ISKDs in 12 patients (13 limbs) failed mechanically representing an overall failure rate of 6.2%, with fracture of the device occurring in ten of the 15 failures. Two nails in one patient failed to lengthen and had to be replaced. The manufacturer detected an error in the assembly of the nail, which prompted a wide recall. One nail jammed after being forcefully inserted, and two nails failed to lengthen fully. Lengthening was achieved in all 12 patients, although three required a second operation to exchange a defective nail for a new, functioning device.

The ISKD is a complex mechanical device which lengthens by the oscillation of two telescopic sections connected by a threaded rod. The junction between these sections is surrounded by a keyring collar. This keyring collar is the weakest part of the device.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 632 - 635
1 May 2009
Adams JE Hoskin TL Morrey BF Steinmann SP

A series of 103 acute fractures of the coronoid process of the ulna in 101 patients was reviewed to determine their frequency. The Regan-Morrey classification, treatment, associated injuries, course and outcomes were evaluated. Of the 103 fractures, 34 were type IA, 17 type IB, ten type IIA, 19 type IIB, ten type IIIA and 13 type IIIB. A total of 44 type-I fractures (86%) were treated conservatively, while 22 type-II (76%) and all type-III fractures were managed by operation.

At follow-up at a mean of 3.4 years (1 to 8.9) the range of movement differed significantly between the types of fracture (p = 0.002). Patients with associated injuries had a lower Mayo elbow performance score (p = 0.03), less extension (p = 0.03), more pain (p = 0.007) and less pronosupination (p = 0.004), than those without associated injuries. The presence of a fracture of the radial head had the greatest effect on outcome. An improvement in outcome relative to that of a previous series was noted, perhaps because of more aggressive management and early mobilisation. While not providing complete information about the true details of a fracture and its nature, the Regan-Morrey classification is useful as a broad index of severity and prognosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1271 - 1278
1 Sep 2011
Pakos EE Grimer RJ Peake D Spooner D Carter SR Tillman RM Abudu S Jeys L

We aimed to identify the incidence, outcome and prognostic factors associated with spindle cell sarcomas of bone (SCSB). We studied 196 patients with a primary non-metastatic tumour treated with the intent to cure. The results were compared with those of osteosarcoma patients treated at our hospital during the same period. The overall incidence of SCSB was 7.8% of all patients with a primary bone sarcoma. The five- and ten-year survival rates were 67.0% and 60.0%, respectively, which were better than those of patients with osteosarcoma treated over the same period. All histological subtypes had similar outcomes. On univariate analysis, factors that were significantly associated with decreased survival were age > 40 years, size > 8 cm, the presence of a pathological fracture, amputation, involved margins and a poor response to pre-operative chemotherapy. Multivariate analyses showed that age > 65 years, amputation and involved margins were all statistically significant prognostic factors. Involved margins and poor response to pre-operative chemotherapy were associated with an increased risk of local recurrence. SCSB has a better prognosis than osteosarcoma when matched for age. Most prognostic factors for osteosarcoma also seem to apply to SCSB. Patients with SCSB should be treated in the same way as patients of the same age with osteosarcoma.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 695 - 699
1 May 2011
Spiro AS Babin K Lipovac S Stenger P Mladenov K Rupprecht M Rueger JM Stuecker R

The use of recombinant human bone morphogenetic protein-2 (rhBMP-2) for the treatment of congenital pseudarthrosis of the tibia has been investigated in only one previous study, with promising results. The aim of this study was to determine whether rhBMP-2 might improve the outcome of this disorder. We reviewed the medical records of five patients with a mean age of 7.4 years (2.3 to 21) with congenital pseudarthrosis of the tibia who had been treated with rhBMP-2 and intramedullary rodding. Ilizarov external fixation was also used in four of these patients. Radiological union of the pseudarthrosis was evident in all of them at a mean of 3.5 months (3.2 to 4) post-operatively. The Ilizarov device was removed after a mean of 4.2 months (3.0 to 5.3). These results indicate that treatment of congenital pseudarthrosis of the tibia using rhBMP-2 in combination with intramedullary stabilisation and Ilizarov external fixation may improve the initial rate of union and reduce the time to union.

Further studies with more patients and longer follow-up are necessary to determine whether this surgial procedure may significantly enhance the outcome of congenital pseudarthrosis of the tibia, considering the refracture rate (two of five patients) in this small case series.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 479 - 483
1 Apr 2011
Chang C Lai K Yang C Lan S

Between April 2004 and July 2007, we performed 241 primary total knee replacements in 204 patients using the e.motion posterior cruciate-retaining, multidirectional mobile-bearing prosthesis. Of these, 100 were carried out using an image-free navigation system, and the remaining 141 with the conventional technique. We conducted a retrospective study from the prospectively collected data of these patients to assess the early results of this new mobile-bearing design.

At a mean follow-up of 49 months (32 to 71), 18 knees (7.5%) had mechanical complications of which 13 required revision. Three of these had a peri-prosthetic fracture, and were removed from the study. The indication for revision in the remaining ten was loosening of the femoral component in two, tibiofemoral dislocation in three, disassociation of the polyethylene liner in four, and a broken polyethyene liner in one. There were eight further mechanically unstable knees which presented with recurrent disassociation of the polyethylene liner. There was no significant difference in the incidence of mechanical instability between the navigation-assisted procedures (8 of 99, 8.1%) and the conventionally implanted knees (10 of 139, 7.2%).

In our view, the relatively high rate of mechanical complications and revision within 30 months precludes the further use of new design of knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1229 - 1233
1 Sep 2007
Bacci G Balladelli A Forni C Longhi A Serra M Fabbri N Alberghini M Ferrari S Benassi MS Picci P

Despite local treatment with systemic chemotherapy in Ewing’s sarcoma family tumours (ESFT), patients with detectable metastases at presentation have a markedly worse prognosis than those with apparently localised disease. We investigated the clinical, pathological and laboratory differences in 888 patients with ESFT, 702 with localised disease and 186 with overt metastases at presentation, seen at our institution between 1983 and 2006.

Multivariate analyses showed that location in the pelvis, a high level of serum lactic dehydrogenase, the presence of fever and a short interval between the onset of symptoms and diagnosis were indicative of metastatic disease. The rate of overt metastases at presentation was 10% without these four risk factors, 22.7% with one, 31.4% with two, and 50% for those with three or four factors. We concluded that in ESFT the site, the serum level of lactic dehydrogenase, fever, and the interval between the onset of symptoms and diagnosis are indicators of tumours having a particularly aggressive metastatic behaviour.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 948 - 952
1 Jul 2007
Mitchell PD Chew NS Goutos I Healy JC Lee JC Evans S Hulme A

Our aim was to determine whether abnormalities noted on MRI immediately after reduction for developmental dysplasia of the hip could predict the persistance of dysplasia and aid surgical planning. Scans of 13 hips in which acetabular dysplasia had resolved by the age of four years were compared with those of five which had required pelvic osteotomy for persisting dysplasia. The scans were analysed by two consultant musculoskeletal radiologists who were blinded to the outcome in each child.

The postreduction scans highlighted a number of anatomical abnormalities secondary to developmental dysplasia of the hip, but statistical analysis showed that none were predictive of persisting acetabular dysplasia in the older child, suggesting that the factors which determine the long-term outcome were not visible on these images.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 587 - 592
1 May 2011
Kim Y Kim J Park J Joo J

We reviewed the results of 84 total hip replacements performed with a short metaphyseal-fitting anatomical cementless femoral component in 84 unselected consecutive patients with a mean age of 78.9 years (70 to 88). The mean follow-up was 4.6 years (4 to 5). The mean pre-operative Harris hip score was 26 points (0 to 56), which improved to 89 (61 to 100) at the final follow-up. No patient had thigh pain. The mean pre-operative Western Ontario and McMaster Universities osteoarthritis index score was 61 points (48 to 75), which improved to 21 (6 to 46). The mean University of California, Los Angeles activity score was 5.5 points (3 to 7) at the final follow-up. Osseointegration was seen in all femoral and acetabular components. All hips had grade 1 stress shielding of the proximal femur. No acetabular or femoral osteolysis was identified.

These results demonstrate that a short metaphyseal-fitting femoral component achieves optimal fixation without diaphyseal anchorage in elderly patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 537 - 541
1 Apr 2011
Song WS Kong C Jeon D Cho WH Kim JR Lee S

The use of allografts for the treatment of bone tumours in children is limited by nonunion and the difficulty of finding a suitable graft. Furthermore, appositional growth can’t be expected of an allograft.

We used an overlapping allograft in 11 children, with a mean age of ten years (4 to 15), with a mean follow-up of 24.1 months (20 to 33). There were five intercalary and six intra-articular resections, and the tumours were in the femur in six cases and the humerus in five. Rates of union, times to union, remodelling patterns and allograft-associated complications were evaluated.

No allograft was removed due to a complication. Of the 16 junctional sites, 15 (94%) showed union at a mean of 3.1 months (2 to 5). Remodelling between host and allograft was seen at 14 junctions at a mean of five months (4 to 7). The mean Musculoskeletal Tumor Society score was 26.5 of 30 (88.3%). One case of nonunion and another with screw protrusion required re-operation.

Overlapping allografts have the potential to shorten time to union, decrease rates of nonunion and have positive appositional growth effect.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 439 - 442
1 Apr 2011
Sexton SA Yeung E Jackson MP Rajaratnam S Martell JM Walter WL Zicat BA Walter WK

We investigated factors that were thought to be associated with an increased incidence of squeaking of ceramic-on-ceramic total hip replacements. Between June 1997 and December 2008 the three senior authors implanted 2406 primary total hip replacements with a ceramic-on-ceramic bearing surface. The mean follow-up was 10.6 years. The diagnosis was primary osteoarthritis in each case, and no patient had undergone previous surgery to the hip. We identified 74 squeaking hips (73 patients) giving an incidence of 3.1% at a mean follow-up of 9.5 years (4.1 to 13.3).

Taller, heavier and younger patients were significantly more likely to have hips that squeaked. Squeaking hips had a significantly higher range of post-operative internal (p = 0.001) and external rotation (p = 0.003) compared with silent hips. Patients with squeaking hips had significantly higher activity levels (p = 0.009). A squeaking hip was not associated with a significant difference in patient satisfaction (p = 0.24) or Harris hip score (p = 0.34). Four implant position factors enabled good prediction of squeaking. These were high acetabular component inclination, high femoral offset, lateralisation of the hip centre and either high or low acetabular component anteversion.

This is the largest study to date to examine patient factors and implant position factors that predispose to squeaking of a ceramic-on-ceramic hip. The results suggest that factors which increase the mechanical forces across the hip joint and factors which increase the risk of neck-to-rim impingement, and therefore edge-loading, are those that predispose to squeaking.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 435 - 438
1 Apr 2011
Gilbody J

Aseptic loosening of the acetabular component continues to be the most common indication for revision of total hip replacements in younger patients. Early in the evolution of the cemented hip, arthroplasty surgeons switched from removal to retention of the acetabular subchondral bone plate, theorising that unfavourable mechanical forces were the cause of loosening at the bone-cement interface.

It is now known that the cause of aseptic loosening is probably biological rather than mechanical and removing the subchondral bone plate may enhance biological fixation of cement to bone. With this in mind, perhaps it is time to revive removal of the subchondral bone as a standard part of acetabular preparation.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 629 - 637
1 May 2008
Forward DP Davis TRC Sithole JS

Fractures of the distal radius occurring in young adults are treated increasingly by open surgical techniques, partly because of concern that failure to restore the alignment of the fracture accurately may cause symptomatic post-traumatic osteoarthritis in future years. We reviewed 106 adults who had sustained a fracture of the distal radius between 1960 and 1968 and who were below the age of 40 years at the time of injury. We carried out a clinical and radiological assessment at a mean follow-up of 38 years (33 to 42).

No patient had required a salvage procedure. While there was radiological evidence of post-traumatic osteoarthritis after an intra-articular fracture in 68% of patients (27 of 40), the disabilities of the arm, shoulder and hand (DASH) scores were not different from population norms, and function, as assessed by the Patient Evaluation Measure, was impaired by less than 10%. Ordinal logistic regression analysis showed a significant relationship between narrowing of the joint space and extra-articular malunion (dorsal angulation and radial shortening) as well as intra-articular injury. Multivariate analysis revealed that grip strength had fallen to 89% of that of the uninjured side in the presence of dorsal malunion, but no measure of extra-articular malunion was significantly related to either the Patient Evaluation Measure or DASH scores.

While anatomical reduction is the principal aim of treatment, imperfect reduction of these fractures may not result in symptomatic arthritis in the long term, and this should be considered when counselling patients on the risks and benefits of the many treatment options available.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 949 - 954
1 Jul 2011
Bisseling P Zeilstra DJ Hol AM van Susante JLC

The purpose of this study was to evaluate whether concerns about the release of metal ions in metal-on-metal total hip replacements (THR) should be extended to patients with metal-bearing total disc replacements (TDR).

Cobalt and chromium levels in whole blood and serum were measured in ten patients with a single-level TDR after a mean follow-up of 34.5 months (13 to 61) using inductively-coupled plasma mass spectrometry. These metal ion levels were compared with pre-operative control levels in 81 patients and with metal ion levels 12 months after metal-on-metal THR (n = 21) and resurfacing hip replacement (n = 36). Flexion-extension radiographs were used to verify movement of the TDR.

Cobalt levels in whole blood and serum were significantly lower in the TDR group than in either the THR (p = 0.007) or the resurfacing group (p < 0.001). Both chromium levels were also significantly lower after TDR versus hip resurfacing (p < 0.001), whereas compared with THR this difference was only significant for serum levels (p = 0.008). All metal ion levels in the THR and resurfacing groups were significantly higher than in the control group (p < 0.001). In the TDR group only cobalt in whole blood appeared to be significantly higher (p < 0.001). The median range of movement of the TDR was 15.5° (10° to 22°).

These results suggest that there is minimal cause for concern about high metal ion concentrations after TDR, as the levels appear to be only moderately elevated. However, spinal surgeons using a metal-on-metal TDR should still be aware of concerns expressed in the hip replacement literature about toxicity from elevated metal ion levels, and inform their patients appropriately.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 26 - 30
1 Jan 2006
Lindahl H Malchau H Odén A Garellick G

Periprosthetic fracture of the femur is an uncommon complication after total hip replacement, but appears to be increasing. We undertook a nationwide observational study to determine the risk factors for failure after treatment of these fractures, examining patient- and implant-related factors, the classification of the fractures and the outcome.

Between 1979 and 2000, 1049 periprosthetic fractures of the femur were reported to the Swedish National Hip Arthroplasty Register. Of these, 245 had a further operation after failure of their initial management. Data were collected from the Register and hospital records. The material was analysed by the use of Poisson regression models.

It was found that the risk of failure of treatment was reduced for Vancouver type B2 injuries (p = 0.0053) if revision of the implant was undertaken (p = 0.0033) or revision and open reduction and internal fixation (p = 0.0039) were performed. Fractures classified as Vancouver type B1 had a significantly higher risk of failure (p = 0.0001). The strongest negative factor was the use of a single plate for fixation (p = 0.001). The most common reasons for failure in this group were loosening of the femoral prosthesis, nonunion and re-fracture.

It is probable that many fractures classified as Vancouver type B1 (n = 304), were in reality type B2 fractures with a loose stem which were not recognised. Plate fixation was inadequate in these cases. The difficulty in separating type B1 from type B2 fractures suggests that the prosthesis should be considered as loose until proven otherwise.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1639 - 1642
1 Dec 2005
Church S Keating JF

We reviewed 183 patients who had undergone reconstruction of the anterior cruciate ligament. The incidence of meniscal tears and degenerative change was assessed and related to the timing from injury to surgery. Degenerative change was scored using the French Society of Arthroscopy system. The patients were divided into an early (surgery within 12 months of injury) and a late group (surgery more than 12 months from injury). The late group was also subdivided into four groups of 12-month periods ranging from one year to more than four years after injury.

There was a significantly higher incidence of meniscal tears in patients undergoing reconstruction after 12 months compared with those in the early group (71.2% vs 41.7%; p < 0.001). This was due to a large increase in medial meniscal tears in the late group. An increased incidence of degenerative change was also found in the late group (31.3% vs 10.7%; p < 0.001). Analysis of the subgroups showed that the incidence of meniscal tears and degenerative change did not differ significantly when surgery was performed after 12 months from injury. We conclude that reconstruction of the anterior cruciate ligament should be carried out within 12 months of injury to minimise the risk of meniscal tears and degenerative change.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 604 - 611
1 May 2009
Reay E Wu J Holland J Deehan D

We describe a cohort of patients with a high rate of mid-term failure following Kinemax Plus total knee replacement inserted between 1998 and 2001. This implant has been recorded as having a survival rate of 96% at ten years. However, in our series the survival rate was 75% at nine years. This was also significantly lower than that of subsequent consecutive series of PFC Sigma knee replacements performed by the same surgeon. No differences were found in the clinical and radiological parameters between the two groups. At revision the most striking finding was polyethylene wear. An independent analysis of the polyethylene components was therefore undertaken. Scanning electron microscopy revealed type 2 fusion defects in the ultra-high molecular weight polyethylene (UHMWPE), which indicated incomplete boundary fusion. Other abnormalities consistent with weak UHMWPE particle interface strength were present in both the explanted inserts and in unused inserts from the same period.

We consider that these type 2 fusion defects are the cause of the early failure of the Kinemax implants. This may represent a manufacturing defect resulting in a form of programmed polyethylene failure.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1470 - 1477
1 Nov 2007
Balg F Boileau P

There is no simple method available to identify patients who will develop recurrent instability after an arthroscopic Bankart procedure and who would be better served by an open operation.

We carried out a prospective case-control study of 131 consecutive unselected patients with recurrent anterior shoulder instability who underwent this procedure using suture anchors. At follow-up after a mean of 31.2 months (24 to 52) 19 (14.5%) had recurrent instability. The following risk factors were identified: patient age under 20 years at the time of surgery; involvement in competitive or contact sports or those involving forced overhead activity; shoulder hyperlaxity; a Hill-Sachs lesion present on an anteroposterior radiograph of the shoulder in external rotation and/or loss of the sclerotic inferior glenoid contour.

These factors were integrated in a 10-point pre-operative instability severity index score and tested retrospectively on the same population. Patients with a score over 6 points had an unacceptable recurrence risk of 70% (p < 0.001). On this basis we believe that an arthroscopic Bankart repair is contraindicated in these patients, to whom we now suggest a Bristow-Latarjet procedure instead.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 726 - 731
1 Jun 2011
Ito H Tanino H Yamanaka Y Nakamura T Minami A Matsuno T

We report the mid- to long-term (mean 20.3 years, 10 to 32.5) results of the Chiari pelvic osteotomy in patients with pre- to advanced stage osteoarthritis in dysplastic hips. We followed 163 Japanese patients (173 hips) with a mean age at surgery of 20 years (9 to 54). Overall, 124 hips (72%) had satisfactory results, with Harris hip scores ≥ 80. Satisfactory results were seen in 105 of 134 hips with pre- or early osteoarthritis (78%) and 19 of 39 hips with advanced osteoarthritis (49%). A total of 15 hips (9%) underwent a total hip replacement (THR) with a mean interval between osteotomy and THR of 16.4 years. With conversion to THR as the endpoint, the 30-year survival rate was 85.9% (95% confidence interval 82.3 to 89.5). It was 91.8% for patients with pre- or early osteoarthritis and 43.6% for those with advanced osteoarthritis (p < 0.001).

We now perform the Chiari osteotomy for patients with dysplastic hips showing poor joint congruency and who prefer a joint-conserving procedure to THR.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1064 - 1068
1 Aug 2007
Berendes TD Wolterbeek R Pilot P Verburg H te Slaa RL

We report the outcome of a modified Bankart procedure using suture anchors in 31 patients (31 shoulders) with a mean follow-up of 11 years (10 to 15). The mean age of the patients was 28 years (16 to 39). At follow-up, the mean Rowe score was 90 points (66 to 98) and the Constant score was 96 points (85 to 100). A total of 26 shoulders (84%) had a good or excellent result. The rate of recurrence varied between 6.7% and 9.7% and depended on how recurrence was defined. Two patients had a significant new injury at one and nine years, respectively after operation. The overall rate of instability (including subluxations) varied between 12.9% and 22.6%. All patients returned to work, with 29 (94%) resuming their pre-operative occupation and level of activity. Mild radiological osteoarthritis was seen in nine shoulders (29%) and severe osteoarthritis in one.

We conclude that the open modified Bankart procedure is a reliable surgical technique with good long-term results.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 841 - 843
1 Jun 2005
Zamzam MM Khoshhal KI

We retrospectively reviewed 183 children with a simple fracture of the distal radius, with or without fracture of the ulna, treated by closed reduction and cast immobilisation. The fracture redisplaced after an initial, acceptable closed reduction in 46 (25%). Complete initial displacement was identified as the most important factor leading to redisplacement. Other contributing factors were the presence of an ipsilateral distal ulnar fracture, and the reduction of completely displaced fractures under deep sedation or local haematoma block. We recommend that completely displaced fractures of the distal radius in children should be reduced under general anaesthesia, and fixed by primary percutaneous Kirschner wires even when a satisfactory closed reduction has been achieved.