In 1999, we developed a technique for biological
reconstruction after excision of a bone tumour, which involved using
autografts of the bone containing the tumour treated with liquid
nitrogen. We have previously reported the use of this technique
in 28 patients at a mean follow up of 27 months (10 to 54). In this study, we included 72 patients who underwent reconstruction
using this technique. A total of 33 patients died and three were
lost to follow-up, at a mean of 23 months (2 to 56) post-operatively,
leaving 36 patients available for a assessment at a mean of 101
months 16 to 163) post-operatively. The methods of reconstruction included
an osteo-articular graft in 16, an intercalary in 13 and, a composite
graft with prosthesis in seven. Post-operative function was excellent in 26 patients (72.2%),
good in seven (19.4%), and fair in three (8.3%) according to the
functional evaluation system of Enneking. No recurrent tumour occurred
within the grafts. The autografts survived in 29 patients (80.6%),
and the rates of survival at five and ten years were 86.1% and 80.6
%, respectively. Seven of 16 osteo-articular grafts (44%) failed
because of fracture or infection, but all the composite and intercalary
grafts survived. The long-term outcomes of frozen autografting, particularly using
composite and intercalary grafts, are satisfactory and thus represent
a good method of treatment for patients with a sarcoma of bone or
soft tissue. Cite this article:
We evaluated an operative technique, described
by the Exeter Hip Unit, to assist accurate introduction of the femoral
component. We assessed whether it led to a reduction in the rate
of leg-length discrepancy after total hip arthroplasty (THA). A total of 100 patients undergoing THA were studied retrospectively;
50 were undertaken using the test method and 50 using conventional
methods as a control group. The groups were matched with respect
to patient demographics and the grade of surgeon. Three observers
measured the depth of placement of the femoral component on post-operative
radiographs and measured the length of the legs. There was a strong correlation between the depth of insertion
of the femoral component and the templated depth in the test group
(R = 0.92), suggesting accuracy of the technique. The mean leg-length
discrepancy was 5.1 mm (0.6 to 21.4) pre-operatively and 1.3 mm
(0.2 to 9.3) post-operatively. There was no difference between Consultants
and Registrars as primary surgeons. Agreement between the templated
and post-operative depth of insertion was associated with reduced
post-operative leg-length discrepancy. The intra-class coefficient
was R ≥ 0.88 for all measurements, indicating high observer agreement.
The post-operative leg-length discrepancy was significantly lower
in the test group (1.3 mm) compared with the control group (6.3
mm, p <
0.001). The Exeter technique is reproducible and leads to a lower incidence
of leg-length discrepancy after THA. Cite this article:
Non-modular tapered fluted, titanium stems are
available for use in femoral revision. The combination of taper
and flutes on the stem provides axial and rotational stability,
respectively. The material and surface properties of the stem promotes
bone on-growth. If the surgeon is confident and reasonably experienced
in the surgical use of this sort of design and the case is relatively
straightforward, a non-modular design is effective. It also potentially reduces
implant inventory, and circumvents the potential problems of taper
junction corrosion and fatigue fracture. There are reports of excellent
survival, good clinical and functional results and evidence of subsequent
increase in proximal bone stock. Cite this article: Bo
Epidemiological studies enhance clinical practice
in a number of ways. However, there are many methodological difficulties
that need to be addressed in designing a study aimed at the collection
and analysis of data concerning fractures and other injuries. Most
can be managed and errors minimised if careful attention is given
to the design and implementation of the research. Cite this article:
This study aimed to determine the long-term functional,
clinical and radiological outcomes in patients with Schatzker IV
to VI fractures of the tibial plateau treated with an Ilizarov frame.
Clinical, functional and radiological assessment was carried out
at a minimum of one year post-operatively. A cohort of 105 patients
(62 men, 43 women) with a mean age of 49 years (15 to 87) and a
mean follow-up of 7.8 years (1 to 19) were reviewed. There were
18 type IV, 10 type V and 77 type VI fractures. All fractures united
with a mean time to union of 20.1 weeks (10.6 to 42.3). No patient
developed a deep infection. The median range of movement (ROM) of
the knee was 110o and the median Iowa score was 85. Our study demonstrates good long-term functional outcome with
no deep infection; spanning the knee had no detrimental effect on
the ROM or functional outcome. High-energy fractures of the tibial plateau may be treated effectively
with a fine wire Ilizarov fixator. Cite this article:
A poor response to chemotherapy (≤ 90% necrosis)
for osteosarcomas leads to poorer survival and an increased risk of
local recurrence, particularly if there is a close margin of excision.
We evaluated whether amputation confers any survival benefit over
limb salvage surgery (LSS) with narrow margins in patients who respond
poorly to chemotherapy. We only analysed patients with an osteosarcoma of the limb, a
poor response to chemotherapy and close margins on LSS (marginal/intralesional)
or primary amputation: 360 patients (36 LSS (intralesional margins),
197 LSS (marginal margins) and 127 amputations) were included. Local
recurrence developed in 13 (36%) following LSS with intralesional
margins, and 39 (20%) following LSS with marginal margins. There
was no local recurrence in patients who underwent amputation. The
five-year survival for all patients was 41% (95% confidence interval
(CI) 35 to 46), but for those treated by LSS with marginal margins
was 46.2% (95% CI 38 to 53), 36.3% (95% CI 27 to 45) for those treated
by amputation, and 28% (95 CI 14 to 44) for those treated by LSS
with intralesional margins. Patients who had LSS and then developed
local recurrence as a first event had the same survival as those
who had primary amputation without local recurrence. Prophylactic
adjuvant radiotherapy was used in 40 patients but had no discernible
effect in preventing local recurrence. Although amputation offered better local control, it conferred
no clear survival benefit over LSS with marginal margins in these
patients with a poor overall prognosis. Cite this article:
The aims of this study were to compare the diagnostic test characteristics
of ultrasound alone, metal artefact reduction sequence MRI (MARS-MRI)
alone, and ultrasound combined with MARS-MRI for identifying intra-operative
pseudotumours in metal-on-metal hip resurfacing (MoMHR) patients
undergoing revision surgery. This retrospective diagnostic accuracy study involved 39 patients
(40 MoMHRs). The time between imaging modalities was a mean of 14.6
days (0 to 90), with imaging performed at a mean of 5.3 months (0.06
to 12) before revision. The prevalence of intra-operative pseudotumours
was 82.5% (n = 33).Aims
Methods
This was a randomised controlled trial studying
the safety of a new short metaphyseal fixation (SMF) stem. We hypothesised
that it would have similar early clinical results and micromovement
to those of a standard-length tapered Synergy metaphyseal fixation
stem. Using radiostereometric analysis (RSA) we compared the two
stems in 43 patients. A short metaphyseal fixation stem was used
in 22 patients and a Synergy stem in 21 patients. No difference
was found in the clinical outcomes pre- or post-operatively between
groups. RSA showed no significant differences two years post-operatively
in mean micromovement between the two stems (except for varus/valgus tilt
at p = 0.05) (subsidence 0.94 mm ( Cite this article:
A retrospective study was performed in 18 patients
with achondroplasia, who underwent bilateral humeral lengthening
between 2001 and 2013, using monorail external fixators. The mean
age was ten years (six to 15) and the mean follow-up was 40 months
(12 to 104). The mean disabilities of the arm, shoulder and hand (DASH) score
fell from 32.3 (20 to 40)
pre-operatively to 9.4 (6 to 14) post-operatively (p = 0.037). A
mean lengthening of 60% (40% to 95%) was required to reach the goal
of independent perineal hygiene. One patient developed early consolidation,
and fractures occurred in the regenerate bone of four humeri in
three patients. There were three transient radial nerve palsies. Humeral lengthening increases the independence of people with
achondroplasia and is not just a cosmetic procedure. Cite this article:
Proximal femoral resection (PFR) is a proven
pain-relieving procedure for the management of patients with severe cerebral
palsy and a painful displaced hip. Previous authors have recommended
post-operative traction or immobilisation to prevent a recurrence
of pain due to proximal migration of the femoral stump. We present
a series of 79 PFRs in 63 patients, age 14.7 years (10 to 26; 35
male, 28 female), none of whom had post-operative traction or immobilisation. A total of 71 hips (89.6%) were reported to be pain free or to
have mild pain following surgery. Four children underwent further
resection for persistent pain; of these, three had successful resolution
of pain and one had no benefit. A total of 16 hips (20.2%) showed
radiographic evidence of heterotopic ossification, all of which
had formed within one year of surgery. Four patients had a wound
infection, one of which needed debridement; all recovered fully.
A total of 59 patients (94%) reported improvements in seating and
hygiene. The results are as good as or better than the historical results
of using traction or immobilisation. We recommend that following
PFR, children can be managed without traction or immobilisation,
and can be discharged earlier and with fewer complications. However,
care should be taken with severely dystonic patients, in whom more
extensive femoral resection should be considered in combination
with management of the increased tone. Cite this article:
We reviewed 34 consecutive patients (18 female-16 male) with
isthmic spondylolysis and grade I to II lumbosacral spondylolisthesis
who underwent in situ posterolateral arthodesis between the L5 transverse
processes and the sacral ala with the use of iliac crest autograft.
Ten patients had an associated scoliosis which required surgical correction
at a later stage only in two patients with idiopathic curves unrelated
to the spondylolisthesis. No patient underwent spinal decompression or instrumentation
placement. Mean surgical time was 1.5 hours (1 to 1.8) and intra-operative
blood loss 200 ml (150 to 340). There was one wound infection treated
with antibiotics but no other complication. Radiological assessment
included standing posteroanterior and lateral, Ferguson and lateral flexion/extension
views, as well as CT scans. Aims
Methods
Most published randomised controlled trials which
compare the rates of wear of conventional and cross-linked (XL) polyethylene
(PE) in total hip arthroplasty (THA) have described their use with
a cementless acetabular component. We conducted a prospective randomised study to assess the rates
of penetration of two distinct types of PE in otherwise identical
cemented all-PE acetabular components. A total of 100 consecutive patients for THA were randomised to
receive an acetabular component which had been either highly XL
then remelted or moderately XL then annealed. After a minimum of eight years follow-up, 38 hips in the XL group
and 30 hips in the annealed group had complete data (mean follow-up
of 9.1 years (7.6 to 10.7) and 8.7 years (7.2 to 10.2), respectively).
In the XL group, the steady state rate of penetration from one year
onwards was -0.0002 mm/year ( These results show that the yearly linear rate of femoral head
penetration can be significantly reduced by using a highly XLPE
cemented acetabular component. Cite this article:
Fractures in patients aged ≥ 65 years constitute
an increasing burden on health and social care and are associated with
a high morbidity and mortality. There is little accurate information
about the epidemiology of fractures in the elderly. We have analysed
prospectively collected data on 4786 in- and out-patients who presented
with a fracture over two one-year periods. Analysis shows that there
are six patterns of the incidence of fractures in patients aged ≥ 65
years. In males six types of fracture increase in incidence after
the age of 65 years and 11 types increase in females aged over 65
years. Five types of fracture decrease in incidence after the age
of 65 years. Multiple fractures increase in incidence in both males
and females aged ≥ 65 years, as do fractures related to falls. Analysis of the incidence of fractures, together with life expectancy,
shows that the probability of males and females aged ≥ 65 years
having a fracture during the rest of their life is 18.5% and 52.0%,
respectively. The equivalent figures for males and females aged ≥ 80
years are 13.3% and 34.8%, respectively. Cite this article:
The April 2015 Trauma Roundup360 looks at: Negative presure wound therapy in open tibial fractures; Priority-driven approach to pelvic injuries; Early surgery essential in hip fracture management; Sheer fractures to the posteromedial plateau; Fasciotomy closure under the spotlight; Why do patients die from hip fracture?; Acetabular fractures down the line; Biomechanics of femoral neck fractures reviewed
Because posterior cruciate ligament (PCL) resection makes flexion
gaps wider in total knee replacement (TKR), preserving or sacrificing
a PCL affects the gap equivalence; however, there are no criteria
for the PCL resection that consider gap situations of each knee.
This study aims to investigate gap characteristics of knees and
to consider the criteria for PCL resection. The extension and flexion gaps were measured, first with the
PCL preserved and subsequently with the PCL removed (in cases in
which posterior substitute components were selected). The PCL preservation
or sacrifice was solely determined by the gap measurement results,
without considering other functions of the PCL such as ‘roll back.’Objectives
Methods
The purpose of this study was to compare the results and complications of tibial lengthening over an intramedullary nail with treatment using the traditional Ilizarov method. In this matched case study, 16 adult patients underwent 19 tibial lengthening over nails (LON) procedures. For the matched case group, 17 patients who underwent 19 Ilizarov tibial lengthenings were retrospectively matched to the LON group.Objectives
Methods
Metaphyseal bone loss is common with revision
total knee replacement (RTKR). Using the Anderson Orthopaedic Research
Institute (AORI) classification, type 2-B and type 3 defects usually
require large metal blocks, bulk structural allograft or highly
porous metal cones. Tibial and femoral trabecular metal metaphyseal
cones are a unique solution for large bone defects. These cones
substitute for bone loss, improve metaphyseal fixation, help correct
malalignment, restore the joint line and may permit use of a shorter
stem. The technique for insertion involves sculpturing of the remaining
bone with a high speed burr and rasp, followed by press-fit of the
cone into the metaphysis. The fixation and osteoconductive properties
of the porous cone outer surface allow ingrowth and encourage long-term
biological fixation. The revision knee component is then cemented
into the porous cone inner surface, which provides superior fixation
compared with cementing into native but deficient metaphyseal bone.
The advantages of the cone compared with allograft include: technical
ease, biological fixation, no resorption, and possibly a lower risk
of infection. The disadvantages include: difficult extraction and
relatively short-term follow-up. Several studies using cones report
promising short-term results for the reconstruction of large bone
defects in RTKR. Cite this article:
Sciatic nerve palsy following total hip arthroplasty
(THA) is a relatively rare yet potentially devastating complication.
The purpose of this case series was to report the results of patients
with a sciatic nerve palsy who presented between 2000 and 2010,
following primary and revision THA and were treated with neurolysis.
A retrospective review was made of 12 patients (eight women and
four men), with sciatic nerve palsy following THA. The mean age
of the patients was 62.7 years (50 to 72; standard deviation 6.9).
They underwent interfascicular neurolysis for sciatic nerve palsy,
after failing a trial of non-operative treatment for a minimum of
six months. Following surgery, a statistically and clinically significant
improvement in motor function was seen in all patients. The mean
peroneal nerve score function improved from 0.42 (0 to 3) to 3 (1
to 5) (p <
0.001). The mean tibial nerve motor function score
improved from 1.75 (1 to 4) to 3.92 (3 to 5) (p = 0.02).The mean
improvement in sensory function was a clinically negligible 1 out
of 5 in all patients. In total, 11 patients reported improvement
in their pain following surgery. We conclude that neurolysis of the sciatic nerve has a favourable
prognosis in patients with a sciatic nerve palsy following THA.
Our findings suggest that surgery should not be delayed for >
12
months following injury. Cite this article:
We used immediate post-operative The bending angles in the sagittal and axial planes were significantly
greater but the coronal-bending angle was significantly less in
the transtibial group than in the anteromedial portal and outside-in
groups (p <
0.001 each). The mean length of the femoral tunnel
in all three planes was significantly greater in the transtibial
group than the anteromedial portal and outside-in groups (p <
0.001 each), but all mean tunnel lengths in the three groups exceeded
30 mm. The only significant difference was the coronal graft- bending
angle in the anteromedial portal and outside-in groups (23.5° Compared with the transtibial technique, the anteromedial portal
and outside-in techniques may reduce the graft-bending stress at
the opening of the femoral tunnel. Despite the femoral tunnel length
being shorter in the anteromedial portal and outside-in techniques
than in the transtibial technique, a femoral tunnel length of more than
30 mm in the anteromedial portal and outside-in techniques may be
sufficient for the graft to heal. Cite this article: