Laffosse J Espié A Bonnevialle N Mansat P Tricoire J Bonnevialle P Chiron P Puget J

We retrospectively analysed the clinical results of 30 patients with injuries of the sternoclavicular joint at a minimum of 12 months’ follow-up. A closed reduction was attempted in 14 cases. It was successful in only five of ten dislocations, and failed in all four epiphyseal disruptions. A total of 25 patients underwent surgical reduction, in 18 cases in conjunction with a stabilisation procedure.

At a mean follow-up of 60 months, four patients were lost to follow-up. The functional results in the remainder were satisfactory, and 18 patients were able to resume their usual sports activity at the same level. There was no statistically significant difference between epiphyseal disruption and sternoclavicular dislocation (p > 0.05), but the functional scores (Simple Shoulder Test, Disability of Arm, Shoulder, Hand, and Constant scores) were better when an associated stabilisation procedure had been performed rather than reduction alone (p = 0.05, p = 0.04 and p = 0.07, respectively).

We recommend meticulous pre-operative clinical assessment with CT scans. In sternoclavicular dislocation managed within the first 48 hours and with no sign of mediastinal complication, a closed reduction can be attempted, although this was unsuccessful in half of our cases. A control CT scan is mandatory. In all other cases, and particularly if epiphyseal disruption is suspected, we recommend open reduction with a stabilisation procedure by costaclavicular cerclage or tenodesis. The use of a Kirschner wire should be avoided.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 234 - 239
1 Feb 2009
Puri A Subin BS Agarwal MG

We evaluated the results of fibular centralisation as a stand alone technique to reconstruct defects that occurred after resection of tumours involving the tibial diaphysis and distal metaphysis.

Between January 2003 and December 2006, 15 patients underwent excision of tumours of the tibial diaphysis or distal metaphysis and reconstruction by fibular centralisation. Their mean age was 17 years (7 to 40). Two patients were excluded; one died from the complications of chemotherapy and a second needed a below-knee amputation for a recurrent giant-cell tumour. A total of 13 patients were reviewed after a mean follow-up of 29 months (16 to 48). Only 16 of 26 host graft junctions united primarily. Ten junctions in ten patients needed one or more further procedure before union was achieved. At final follow-up 12 of the 13 patients had fully united grafts; 11 walked without aids. The mean time to union at the junctions that united was 12 months (3 to 36). The mean Musculoskeletal Tumor Society Score was 24.7 (16 to 30).

Fibular centralisation is a durable reconstruction for defects of the tibial diaphysis and distal metaphysis with an acceptable functional outcome. Stable osteosynthesis is the key to successful union. Additional bone grafting is recommended for patients who need postoperative radiotherapy.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 82 - 87
1 Jan 2005
Gadgil A Hayhurst C Maffulli N Dwyer JSM

Between January 1995 and December 2000, 112 children with a closed displaced supracondylar fracture of the humerus without vascular deficit, were managed by elevated, straight-arm traction for a mean of 22 days. The final outcome was assessed using clinical (flexion-extension arc, carrying angle and residual rotational deformity) and radiographic (metaphyseal-diaphyseal angle and humerocapitellar angle) criteria. Excellent results were achieved in 71 (63%) patients, 33 (29%) had good results, 5 (4.4%) fair, and 3 (2.6%) poor. All patients with fair or poor outcomes were older than ten years of age.

Elevated, straight-arm traction is safe and effective in children younger than ten years. It can be effectively used in an environment that can provide ordinary paediatric medical care and general orthopaedic expertise. The outcomes compare with supracondylar fractures treated surgically in specialist centres.


Bone & Joint Research
Vol. 3, Issue 6 | Pages 187 - 192
1 Jun 2014
Penn-Barwell JG Rand BCC Brown KV Wenke JC

Objectives

The purpose of this study was to refine an accepted contaminated rat femur defect model to result in an infection rate of approximately 50%. This threshold will allow examination of treatments aimed at reducing infection in open fractures with less risk of type II error.

Methods

Defects were created in the stablised femurs of anaethetised rats, contaminated with Staphylococcus aureus and then debrided and irrigated six hours later. After 14 days, the bone and implants were harvested for separate microbiological analysis. This basic model was developed in several studies by varying the quantity of bacterial inoculation, introducing various doses of systemic antibiotics with and without local antibiotics.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1592 - 1596
1 Dec 2007
Fraitzl CR Käfer W Nelitz M Reichel H

Conventional treatment of mild slipped capital femoral epiphysis consists of fixation in situ with wires or screws. Recent contributions to the literature suggest that even a mild slip may lead to early damage of the acetabular labrum and adjacent cartilage by abutment of a prominent femoral metaphysis. It has been suggested that the appropriate treatment in mild slipped capital femoral epiphysis should not only prevent further slipping of the epiphysis, but also address potential femoroacetabular impingement by restoring the anatomy of the proximal femur.

Between October 1984 and December 1995 we treated 16 patients for unilateral mild slipped capital femoral epiphysis by fixation in situ with Kirschner wires. In this study we have reviewed these patients for clinical and radiological evidence of femoroacetabular impingement. There was little clinical indication of impingement but radiological evaluation assessing the femoral head-neck ratio and measuring the Nötzli α angle on the anteroposterior and cross-table radiographs showed significant alterations in the proximal femur. None of the affected hips had a normal head-neck ratio and the mean α angle was 86° (55° to 99°) and 55° (40° to 94°) on the anteroposterior and lateral cross-table radiographs, respectively.

While our clinical data favours conventional treatment, our radiological findings are in support of restoring the anatomy of the proximal femur to avoid or delay the development of femoroacetabular impingement following mild slipped capital femoral epiphysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 646 - 650
1 May 2007
Lee H Kim S

This study aimed to evaluate the use of pin leverage in the reduction of Gartland type III supracondylar fractures of the humerus in children. The study comprised 95 children, who were split into three groups according to the type of method of reduction used. Group 1, had an open reduction, group 2, had closed reduction and percutaneous pin fixation and group 3, the pin leverage technique. Each group was analysed according to the time to surgery, the duration of the procedure, the incidence of complications, and the clinical and radiological outcome.

The mean duration of the operative procedure in groups 1, 2 and 3 was 119 minutes (80 to 235), 57 minutes (20 to 110) and 68 minutes (30 to 90), respectively. At a mean follow-up of 30 months (12 to 63) the clinical results were declared excellent or good in all children and the radiological results intermediate in five patients in group 2. The results of the closed reduction using the pin leverage technique was classified as failure in two children.

Our findings lead us to believe that the pin leverage method of reduction gives good results in the treatment of Gartland type III fractures.


Bone & Joint 360
Vol. 3, Issue 2 | Pages 20 - 22
1 Apr 2014

The April 2014 Trauma Roundup360 looks at: is it safe to primarily close dog bite wounds?; conservative transfusion evidence based in hip fracture surgery; tibial nonunion is devastating to quality of life; sexual dysfunction after traumatic pelvic fracture; hemiarthroplasty versus fixation in displaced femoral neck fractures; silver VAC dressings “Gold Standard” in massive wounds; dual plating for talar neck fracture; syndesmosis and fibular length easiest errors in ankle fracture surgery; and dual mobility: stable as a rock in fracture.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1508 - 1513
1 Nov 2013
Ploegmakers JJW The B Brutty M Ackland TR Wang AW

The aim of this study was to determine the effect of a Galeazzi fracture on the strength of pronation and supination at a mean of two years after surgical treatment. The strength of pronation and supination was measured in varying rotational positions of the forearm of ten male patients (mean age 38.9 years (21 to 64)) who had undergone plate fixation for a Galeazzi fracture. The stability of the distal radioulnar joint was assessed, and a clinical assessment using the quick-Disabilities of the Arm Shoulder and Hand (quickDASH) questionnaire and patient-related wrist examination (PRWE) scores was undertaken. In addition, the strength of pronation and supination was measured in a male control group of 42 healthy volunteers (mean age 21.8 years (18 to 37)).

The mean absolute loss of strength of supination in the injured compared with the non-injured arm throughout all ranges of forearm rotation was 16.1 kg (sem 5.3), corresponding to a relative loss of 12.5% (95% confidence interval (CI) 3.6 to 21.4). For the strength of pronation, the mean loss was 19.1 kg (sem 4.5), corresponding to a relative loss of 27.2% (95% CI 14.2 to 40.1). Loss of strength of supination following a Galeazzi fracture correlated with poor quickDASH (p = 0.03) and PRWE scores (p < 0.01).

Loss of strength of pronation (27.2%), and of supination (12.5%) in particular, after a Galeazzi fracture is associated with worse clinical scores, highlighting the importance of supination of the forearm in function of the upper limb.

Cite this article: Bone Joint J 2013;95-B:1508–13.


Bone & Joint 360
Vol. 2, Issue 5 | Pages 37 - 39
1 Oct 2013

The October 2013 Children’s orthopaedics Roundup360 looks at: Half a century of Pavlik treatment; Step away from the child!: trends in fracture management; Posterolateral rotatory elbow instability in children; Osteochondral lesions undiagnosed in patellar dislocations; Oral bisphosphonates in osteogenesis imperfecta; Crossed or parallel pins in supracondylar fractures?; Not too late nor too early: getting epiphysiodesis right; Fixation of supramalleolar osteotomies.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1521 - 1525
1 Nov 2009
Mangat KS Martin AG Bache CE

We compared two management strategies for the perfused but pulseless hand after stabilisation of a Gartland type III supracondylar fracture. We identified 19 patients, of whom 11 were treated conservatively after closed reduction (group 1). Four required secondary exploration, of whom three had median and/or anterior interosseus nerve palsy at presentation. All four were found to have tethering or entrapment of both nerve and vessel at the fracture site. Only two regained patency of the brachial artery, and one patient has a persistent neurological deficit.

In six of the eight patients who were explored early (group 2) the vessel was tethered at the fracture site. In group 2 four patients also had a nerve palsy at presentation and were similarly found to have tethering or entrapment of both the nerve and the vessel. The patency of the brachial artery was restored in all six cases and their neurological deficits recovered completely.

We would recommend early exploration of a Gartland type III supracondylar fracture in patients who present with a coexisting anterior interosseous or median nerve palsy, as these appear to be strongly predictive of nerve and vessel entrapment.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 983 - 987
1 Jul 2013
Soliman O Koptan W Zarad A

In Neer type II (Robinson type 3B) fractures of the distal clavicle the medial fragment is detached from the coracoclavicular ligaments and displaced upwards, whereas the lateral fragment, which is usually small, maintains its position. Several fixation techniques have been suggested to treat this fracture. The aim of this study was to assess the outcome of patients with type II distal clavicle fractures treated with coracoclavicular suture fixation using three loops of Ethibond. This prospective study included 14 patients with Neer type II fractures treated with open reduction and coracoclavicular fixation. Ethibond sutures were passed under the coracoid and around the clavicle (UCAC loop) without making any drill holes in the proximal or distal fragments. There were 11 men and three women with a mean age of 34.57 years (29 to 41). Patients were followed for a mean of 24.64 months (14 to 31) and evaluated radiologically and clinically using the Constant score. Fracture union was obtained in 13 patients at a mean of 18.23 weeks (13 to 23) and the mean Constant score was 96.07 (91 to 100). One patient developed an asymptomatic fibrous nonunion at one year. This study suggests that open reduction and internal fixation of unstable distal clavicle fractures using UCAC loops can provide rigid fixation and lead to bony union. This technique avoids using metal hardware, preserves the acromioclavicular joint and provides adequate stability with excellent results.

Cite this article: Bone Joint J 2013;95-B:983–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1069 - 1076
1 Aug 2007
Goris RJA Leixnering M Huber W Figl M Jaindl M Redl H

We studied prospectively the regional inflammatory response to a unilateral distal radial fracture in 114 patients at eight to nine weeks after injury and again at one year. Our aim was to identify patients at risk for a delayed recovery and particularly those likely to develop complex regional pain syndrome. In order to quantify clinically the inflammatory response, a regional inflammatory score was developed. In addition, blood samples were collected from the antecubital veins of both arms for comparative biochemical and blood-gas analysis.

The severity of the inflammatory response was related to the type of treatment (Kruskal-Wallis test, p = 0.002). A highly significantly-positive correlation was found between the regional inflammatory score and the length of time to full recovery (r2 = 0.92, p = 0.01, linear regession). A regional inflammatory score of 5 points with a sensitivity of 100% but a specificity of only 16% also identified patients at risk of complex regional pain syndrome. None of the biochemical parameters studied correlated with regional inflammatory score or predicted the development of complex regional pain syndrome.

Our study suggests that patients with a distal radial fracture and a regional inflammatory score of 5 points or more at eight to nine weeks after injury should be considered for specific anti-inflammatory treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 146 - 152
1 Jan 2010
Bilen FE Kocaoglu M Eralp L Balci HI

We report the results of using a combination of fixator-assisted nailing with lengthening over an intramedullary nail in patients with tibial deformity and shortening. Between 1997 and 2007, 13 tibiae in nine patients with a mean age of 25.4 years (17 to 34) were treated with a unilateral external fixator for acute correction of deformity, followed by lengthening over an intramedullary nail with a circular external fixator applied at the same operating session. At the end of the distraction period locking screws were inserted through the intramedullary nail and the external fixator was removed.

The mean amount of lengthening was 5.9 cm (2 to 8). The mean time of external fixation was 90 days (38 to 265). The mean external fixation index was 15.8 days/cm (8.9 to 33.1) and the mean bone healing index was 38 days/cm (30 to 60).

One patient developed an equinus deformity which responded to stretching and bracing. Another developed a drop foot due to a compartment syndrome, which was treated by fasciotomy. It recovered in three months. Two patients required bone grafting for poor callus formation.

We conclude that the combination of fixator-assisted nailing with lengthening over an intramedullary nail can reduce the overall external fixation time and prevent fractures and deformity of the regenerated bone.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 694 - 698
1 May 2013
Benedetti Valentini M Farsetti P Martinelli O Laurito A Ippolito E

Of 48 consecutive children with Gartland III supracondylar fractures, 11 (23%) had evidence of vascular injury, with an absent radial pulse. The hand was pink and warm in eight and white and cold in the other three patients. They underwent colour-coded duplex scanning (CCDS) and ultrasound velocimetry (UV) to investigate the patency of the brachial artery and arterial blood flow. In seven patients with a pink pulseless hand, CCDS showed a displaced, kinked and spastic brachial artery and a thrombosis was present in the other. In all cases UV showed reduced blood flow in the hand. In three patients with a white pulseless hand, scanning demonstrated a laceration in the brachial artery and/or thrombosis. In all cases, the fracture was reduced under general anaesthesia and fixed with Kirschner wires. Of the seven patients with a pink pulseless hand without thrombosis, the radial pulse returned after reduction in four cases. The remaining three underwent exploration, along with the patients with laceration in the brachial artery and/or thrombosis.

We believe that the traditional strategy of watchful waiting in children in whom the radial pulse remains absent in spite of good peripheral perfusion should be revisited. Vascular investigation using these non-invasive techniques that are quick and reliable is recommended in the management of these patients.

Cite this article: Bone Joint J 2013;95-B:694–98.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1164 - 1171
1 Sep 2009
Bae DK Song SJ Yoon KH

We assessed the reliability, accuracy and variability of closed-wedge high tibial osteotomy (HTO) using computer-assisted surgery compared to the conventional technique. A total of 50 closed-wedge HTO procedures were performed using the navigation system, and compared with 50 HTOs that had been performed with the conventional technique. In the navigation group, the mean mechanical axis prior to osteotomy was varus 8.2°, and the mean mechanical axis following fixation was valgus 3.6°. On the radiographs the mean pre-operative mechanical axis was varus 7.3°, and the mean post-operative mechanical axis was valgus 2.1°. There was a positive correlation between the measured data taken under navigation and by radiographs (r > 0.3, p < 0.05). The mean correction angle was significantly more accurate in the navigation group (p < 0.002). The variability of the correction was significantly lower in the navigation group (2.3° vs 3.7°, p = 0,012). We conclude that navigation provides reliable real-time intra-operative information, may increase accuracy, and improves the precision of a closed-wedge HTO.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 426 - 433
1 Apr 2009
Musahl V Tarkin I Kobbe P Tzioupis C Siska PA Pape H

The operative treatment of displaced fractures of the tibial plateau is challenging. Recent developments in the techniques of internal fixation, including the development of locked plating and minimal invasive techniques have changed the treatment of these fractures. We review current surgical approaches and techniques, improved devices for internal fixation and the clinical outcome after utilisation of new methods for locked plating.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 527 - 531
1 Apr 2007
Yun Y Shin S Moon J

We reviewed 22 children with cubitus varus who had been treated by a reverse V osteotomy and fixation by cross-pinning and wiring. The mean pre-operative humeral-elbow-wrist angle was −16.9° (−25° to +9°) and at the latest follow-up it was +7.3° (−2° to +14°). No child had a lateral prominence greater than 5 mm after correction. An excellent result was achieved in 20 children and a good result in two. We believe that this osteotomy has the advantages of better inherent stability, the avoidance of a prominent lateral condyle after correction and firm fixation allowing early movement.


Bone & Joint 360
Vol. 1, Issue 4 | Pages 29 - 31
1 Aug 2012

The August 2012 Children’s orthopaedics Roundup360 looks at: whether 3D-CT gives a better idea of coverage than plain radiographs; forearm fractures after trampolining accidents; forearm fractures and the Rush pin; the fractured distal radius; elastic stable intramedullary nailing for long-bone fractures; aponeurotic recession for the equinus foot; the torn medial patellofemoral ligament and the adductor tubercle; slipped capital femoral epiphysis; paediatric wrist arthroscopy; and Pirani scores and clubfoot.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 627 - 632
1 May 2007
Ramamurthy C Cutler L Nuttall D Simison AJM Trail IA Stanley JK

This study identified variables which influence the outcome of surgical management on 126 ununited scaphoid fractures managed by internal fixation and non-vascular bone grafting. The site of fracture was defined by a new method: the ratio of the length of the proximal fragment to the sum of the lengths of both fragments, calculated using specific views in the plain radiographs. Bone healing occurred in 71% (89) of cases. Only the site of nonunion (p = 1 × 10−6) and the delay to surgery (p = 0.001) remained significant on multivariate analysis. The effect of surgical delay on the probability of union increased as the fracture site moved proximally. A prediction model was produced by stepwise logistic regression analysis, enabling the surgeon to predict the success of surgery where the site of the nonunion and delay to surgery is known.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1448 - 1454
1 Nov 2012
Ng CY Watts AC

Bone loss involving articular surface is a challenging problem faced by the orthopaedic surgeon. In the hand and wrist, there are articular defects that are amenable to autograft reconstruction when primary fixation is not possible. In this article, the surgical techniques and clinical outcomes of articular reconstructions in the hand and wrist using non-vascularised osteochondral autografts are reviewed.