The recent development of locking-plate technology has led to a potential revolution in the management of fractures of the distal radius. This review examines the evidence for pursuing anatomical restoration of the distal radius and the possible advantages and pitfalls of using volar locking plates to achieve this goal. The available evidence for adopting volar locking plates is presented and a number of important and, as yet unanswered, questions are highlighted.
Post-operative complications after total hip
or knee replacement can delay recovery, prolong hospitalisation, increase
rates of re-admission and, in the most severe cases, lead to long-term
disability or even death. In this analysis of pooled data from four
large, randomised, phase III clinical trials that compared the oral,
direct Factor Xa inhibitor rivaroxaban with subcutaneous enoxaparin
for the prevention of venous thromboembolism after total hip or
knee replacement (n = 12 729), the incidence of complications, including
bleeding and adverse events related to surgery (such as wound infection,
wound dehiscence and haemarthrosis) are reported. Interventions
and procedures relating to surgery are also compared between the
groups. Bleeding events, including excessive wound haematoma and
surgical-site bleeding, occurred at similar rates in the rivaroxaban
and enoxaparin groups. Over the total study duration, adverse surgical
events occurred at a similar rate in the rivaroxaban group compared
with the enoxaparin group after total knee replacement (2.26% This analysis shows that the incidence of adverse surgical events
with rivaroxaban was similar to enoxaparin.
Several aspects of the management of an orthopaedic surgical patient are not directly related to the surgical technique but are nevertheless essential for a successful outcome. Blood management is one of these. This paper considers the various strategies available for the management of blood loss in patients undergoing orthopaedic and trauma surgery.
Despite many claims of good wear properties following
total knee replacement (TKR) with an oxidised zirconium (OxZr) femoral
component, there are conflicting clinical results. We hypothesised
that there would be no difference in either the mid-term clinical
and radiological outcomes or the characteristics of the polyethylene
wear particles (weight, size and shape) in patients using an OxZr
or cobalt-chrome (CoCr) femoral component. In all 331 patients underwent
bilateral TKR, receiving an OxZr femoral component in one knee and
a CoCr femoral component in the other. The mean follow-up was 7.5
years (6 to 8). Following aspiration, polyethylene wear particles
were analysed using thermogravimetric methods and scanning electron
microscopy. At the most recent follow-up, the mean Knee Society
score, Western Ontario and McMaster Universities Osteoarthritis
Index score, range of movement and satisfaction score were not significantly
different in the two groups. The mean weight, size, aspect ratio
and roundness of the aspirated wear particles were similar for each
femoral component. Survivorship of the femoral, tibial and patellar
components was 100% in both groups. In the absence of evidence of an advantage in the medium term
we cannot justify the additional expense of an OxZr femoral component.
Scapulothoracic fusion (STF) for painful winging
of the scapula in neuromuscular disorders can provide effective pain
relief and functional improvement, but there is little information
comparing outcomes between patients with dystrophic and non-dystrophic
conditions. We performed a retrospective review of 42 STFs in 34
patients with dystrophic and non-dystrophic conditions using a multifilament
trans-scapular, subcostal cable technique supported by a dorsal
one-third semi-tubular plate. There were 16 males and 18 females
with a mean age of 30 years (15 to 75) and a mean follow-up of 5.0
years (2.0 to 10.6). The mean Oxford shoulder score improved from
20 (4 to 39) to 31 (4 to 48). Patients with non-dystrophic conditions
had lower overall functional scores but achieved greater improvements
following STF. The mean active forward elevation increased from
59° (20° to 90°) to 97° (30° to 150°), and abduction from 51° (10°
to 90°) to 83° (30° to 130°) with a greater range of movement achieved
in the dystrophic group. Revision fusion for nonunion was undertaken
in five patients at a mean time of 17 months (7 to 31) and two required
revision for fracture. There were three pneumothoraces, two rib
fractures, three pleural effusions and six nonunions. The main risk
factors for nonunion were smoking, age and previous shoulder girdle surgery. STF is a salvage procedure that can provide good patient satisfaction
in 82% of patients with both dystrophic and non-dystrophic pathologies,
but there was a relatively high failure rate (26%) when poor outcomes
were analysed. Overall function was better in patients with dystrophic
conditions which correlated with better range of movement; however,
patients with non-dystrophic conditions achieved greater functional
improvement.
Intraspinal re-implantation after traumatic avulsion of the brachial plexus is a relatively new technique. Three different approaches to the spinal cord have been described to date, namely the posterior scapular, anterolateral interscalenic multilevel oblique corpectomy and the pure lateral. We describe an anatomical study of the pure lateral approach, based on our clinical experience and studies on cadavers.
This review considers the surgical treatment
of displaced fractures involving the knee in elderly, osteoporotic patients.
The goals of treatment include pain control, early mobilisation,
avoidance of complications and minimising the need for further surgery.
Open reduction and internal fixation (ORIF) frequently results in
loss of reduction, which can result in post-traumatic arthritis
and the occasional conversion to total knee replacement (TKR). TKR
after failed internal fixation is challenging, with modest functional
outcomes and high complication rates. TKR undertaken as treatment
of the initial fracture has better results to late TKR, but does
not match the outcome of primary TKR without complications. Given
the relatively infrequent need for late TKR following failed fixation,
ORIF is the preferred management for most cases. Early TKR can be
considered for those patients with pre-existing arthritis, bicondylar
femoral fractures, those who would be unable to comply with weight-bearing restrictions,
or where a single definitive procedure is required.
Periprosthetic infection following total hip replacement can be a catastrophic complication for the patient. The treatments available include single-stage exchange, and two-stage exchange. We present a series of 50 consecutive patients with a diagnosis of infected total hip replacement who were assessed according to a standardised protocol. Of these, 11 underwent single-stage revision arthroplasty with no recurrence of infection at a mean of 6.8 years follow-up (5.5 to 8.8). The remaining 39 underwent two-stage revision, with two recurrences of infection successfully treated by a second two-stage procedure. At five years, significant differences were found in the mean Harris Hip Scores (single-stage 87.8; two-stage 75.5; p = 0.0003) and in a visual analogue score for satisfaction (8.6; 6.9; p = 0.001) between the single- and two-stage groups. Single-stage exchange is successful in eradicating periprosthetic infection and results in excellent functional and satisfaction scores. Identification of patients suitable for the single-stage procedure allows individualisation of care and provides as many as possible with the correct strategy in successfully tackling their periprosthetic infection
The April 2012 Knee Roundup360 looks at the torn ACL, ACL reconstruction, the risk of ACL rupture, the benefit of warm-ups before exercise, glucosamine and tibiofemoral osteoarthritis, sensitisation and sporting tendinopathy, pain relief after TKR, the long-term results of the Genesis I, the gender specific recovery times after TKR, and the accuracy of the orthopaedic eyeball
Using meta-analysis we compared the survival and clinical outcomes of cemented and uncemented techniques in primary total knee replacement. We reviewed randomised controlled trials and observational studies comparing cemented and uncemented fixation. Our primary outcome was survival of the implant free of aseptic loosening. Our secondary outcome was joint function as measured by the Knee Society score. We identified 15 studies that met our final eligibility criteria. The combined odds ratio for failure of the implant due to aseptic loosening for the uncemented group was 4.2 (95% confidence interval (CI) 2.7 to 6.5) (p <
0.0001). Subgroup analysis of data only from randomised controlled trials showed no differences between the groups for odds of aseptic loosening (odds ratio 1.9, 95% CI 0.55 to 6.40, p = 0.314). The weighted mean difference for the Knee Society score was 0.005 (95% CI −0.26 to 0.26) (p = 0.972). There was improved survival of the cemented compared to uncemented implants, with no statistically significant difference in the mean Knee Society score between groups for all pooled data.
The risk of venous thromboembolism in patients following arthroplasty may be reduced by continuing chemical thromboprophylaxis for up to 35 days post-operatively. This prospective cohort study investigated the compliance of 40 consecutive consenting patients undergoing lower limb arthroplasty with self-administration of a recommended subcutaneous chemotherapeutic agent for six weeks after surgery. Compliance was assessed by examination of the patient for signs of injection, number of syringes used, and a self-report diary at the end of the six-week period. A total of 40 patients, 15 men and 25 women, were recruited. One woman was excluded because immediate post-operative complications prevented her participation. Self-administration was considered feasible in 87% of patients (95% confidence interval (CI) 76 to 98) at the time of discharge. Among this group of 34 patients, 29 (85%) were compliant (95% CI 73 to 97). Patients can learn to self-administer subcutaneous injections of thromboprophylaxis, and compliance with extended prophylaxis to six weeks is good.
To study the vascularity and bone metabolism of the femoral head/neck
following hip resurfacing arthroplasty, and to use these results
to compare the posterior and the trochanteric-flip approaches. In our previous work, we reported changes to intra-operative
blood flow during hip resurfacing arthroplasty comparing two surgical
approaches. In this study, we report the vascularity and the metabolic
bone function in the proximal femur in these same patients at one
year after the surgery. Vascularity and bone function was assessed
using scintigraphic techniques. Of the 13 patients who agreed to
take part, eight had their arthroplasty through a posterior approach
and five through a trochanteric-flip approach.Objectives
Methods
We present our experience with a double-mobility
acetabular component in 155 consecutive revision total hip replacements
in 149 patients undertaken between 2005 and 2009, with particular
emphasis on the incidence of further dislocation. The mean age of
the patients was 77 years (42 to 89) with 59 males and 90 females.
In all, five patients died and seven were lost to follow-up. Indications
for revision were aseptic loosening in 113 hips, recurrent instability
in 29, peri-prosthetic fracture in 11 and sepsis in two. The mean
follow-up was 42 months (18 to 68). Three hips (2%) in three patients
dislocated within six weeks of surgery; one of these dislocated
again after one year. All three were managed successfully with closed
reduction. Two of the three dislocations occurred in patients who
had undergone revision for recurrent dislocation. All three were
found at revision to have abductor deficiency. There were no dislocations
in those revised for either aseptic loosening or sepsis. These results demonstrate a good mid-term outcome for this component.
In the 29 patients revised for instability, only two had a further
dislocation, both of which were managed by closed reduction.
We analysed the outcome of patients with primary
non-metastatic diaphyseal sarcomas who had Extracorporeal irradiation is an oncologically safe and inexpensive
technique for limb salvage in diaphyseal sarcomas and has good functional
results.
Comparison of the safety and efficacy of bilateral simultaneous total hip replacement (THR) and that of staged bilateral THR and unilateral THR was conducted using DerSimonian-Laird heterogeneity meta-analysis. A review of the English-language literature identified 23 citations eligible for inclusion. A total of 2063 bilateral simultaneous THR patients were identified. Meta-analysis of homogeneous data revealed no statistically significant differences in the rates of thromboembolic events (p = 0.268 and p = 0.365) and dislocation (p = 0.877) when comparing staged or unilateral with bilateral simultaneous THR procedures. A systematic analysis of heterogeneous data demonstrated that the mean length of hospital stay was shorter after bilateral simultaneous THR. Higher blood transfusion requirements were expected following bilateral simultaneous THR than staged or unilateral THR, and surgical time was not different between groups. This procedure was also found to be economically and functionally efficacious when performed by experienced surgeons in specialist centres.
We randomly allocated 60 consecutive patients with fractures of the waist of the scaphoid to percutaneous fixation with a cannulated Acutrak screw or immobilisation in a cast. The range of movement, the grip and pinch strength, the modified Green/O’Brien functional score, return to work and sports, and radiological evidence of union were evaluated at each follow-up visit. Patients were followed sequentially for one year. Those undergoing percutaneous screw fixation showed a quicker time to union (9.2 weeks We recommend that all active patients should be offered percutaneous stabilisation for fractures of the waist of the scaphoid.
Controversy continues to surround the management
of patients with an open fracture of the lower limb and an associated
vascular injury (Gustilo type IIIC). This study reports our 15-year
experience with these fractures and their outcome in 18 patients
(15 male and three female). Their mean age was 30.7 years (8 to
54) and mean Mangled Extremity Severity Score (MESS) at presentation
was 6.9 (3 to 10). A total of 15 lower limbs were salvaged and three underwent
amputation (two immediate and one delayed). Four patients underwent
stabilisation of the fracture by external fixation and 12 with an
internal device. A total of 11 patients had damage to multiple arteries
and eight had a vein graft. Wound cover was achieved with a pedicled
flap in three and a free flap in six. Seven patients developed a
wound infection and four developed nonunion requiring further surgery.
At a mean follow-up of five years (4.1 to 6.6) the mean visual analogue
scale for pain was 64 (10 to 90). Depression and anxiety were common.
Activities were limited mainly because of pain, and the MESS was
a valid predictor of the functional outcome. Distal tibial fractures
had an increased rate of nonunion when associated with posterior
tibial artery damage, and seven patients (39%) were not able to
return to their previous occupation.
We report a systematic review and meta-analysis
of the peer-reviewed literature focusing on metal sensitivity testing
in patients undergoing total joint replacement (TJR). Our purpose
was to assess the risk of developing metal hypersensitivity post-operatively
and its relationship with outcome and to investigate the advantages
of performing hypersensitivity testing. We undertook a comprehensive search of the citations quoted in
PubMed and EMBASE: 22 articles (comprising 3634 patients) met the
inclusion criteria. The frequency of positive tests increased after
TJR, especially in patients with implant failure or a metal-on-metal
coupling. The probability of developing a metal allergy was higher
post-operatively (odds ratio (OR) 1.52 (95% confidence interval
(CI) 1.06 to 2.31)), and the risk was further increased when failed
implants were compared with stable TJRs (OR 2.76 (95% CI 1.14 to
6.70)). Hypersensitivity testing was not able to discriminate between
stable and failed TJRs, as its predictive value was not statistically
proven. However, it is generally thought that hypersensitivity testing
should be performed in patients with a history of metal allergy
and in failed TJRs, especially with metal-on-metal implants and
when the cause of the loosening is doubtful.
This study prospectively compared the efficacy of kyphoplasty using a Jack vertebral dilator and balloon kyphoplasty to treat osteoporotic compression fractures between T10 and L5. Between 2004 and 2009, two groups of 55 patients each underwent vertebral dilator kyphoplasty and balloon kyphoplasty, respectively. Pain, function, the Cobb angle, and the anterior and middle height of the vertebral body were assessed before and after operation. Leakage of bone cement was recorded. The post-operative change in the Cobb angle was significantly greater in the dilator kyphoplasty group than in the balloon kyphoplasty group (−9.51° ( These findings suggest that vertebral dilator kyphoplasty can facilitate better correction of kyphotic deformity and may ultimately be a safer procedure in reducing leakage of bone cement.