Induced membrane technique is a relatively new technique in the reconstruction of large bone defects. It involves the implantation of polymethylmethacrylate (PMMA) cement in the bone defects to induce the formation of membranes after radical debridement and reconstruction of bone defects using an autologous cancellous bone graft in a span of four to eight weeks. The purpose of this study was to explore the clinical outcomes of the induced membrane technique for the treatment of post-traumatic osteomyelitis in 32 patients. A total of 32 cases of post-traumatic osteomyelitis were admitted to our department between August 2011 and October 2012. This retrospective study included 22 men and ten women, with a mean age of 40 years (19 to 70). Within this group there were 20 tibias and 12 femurs with a mean defect of 5 cm (1.5 to 12.5). Antibiotic-loaded PMMA cement was inserted into the defects after radical debridement. After approximately eight weeks, the defects were implanted with bone graft.Objectives
Methods
Adverse reaction to wear and corrosion debris
is a cause for concern in total hip arthroplasty (THA). Modular junctions
are a potential source of such wear products and are associated
with secondary pseudotumour formation. We present a consecutive series of 17 patients treated at our
unit for this complication following metal-on-highly cross-linked
polyethylene (MoP) THA. We emphasise the risk of misdiagnosis as
infection, and present the aggregate laboratory results and pathological
findings in this series. The clinical presentation was pain, swelling or instability.
Solid, cystic and mixed soft-tissue lesions were noted on imaging
and confirmed intra-operatively. Corrosion at the head–neck junction
was noted in all cases. No bacteria were isolated on multiple pre-
and intra-operative samples yet the mean erythrocyte sedimentation
rate was 49 (9 to 100) and C-reactive protein 32 (0.6 to 106) and
stromal polymorphonuclear cell counts were noted in nine cases. Adverse soft–tissue reactions can occur in MoP THA owing to corrosion
products released from the head–neck junction. The diagnosis should
be carefully considered when investigating pain after THA. This
may avoid the misdiagnosis of periprosthetic infection with an unidentified
organism and mitigate the unnecessary management of these cases
with complete single- or two-stage exchange. Cite this article:
The June 2015 Wrist &
Hand Roundup360 looks at: Collagenase and Dupuytren’s disease – a genuine alternative to surgery?; iPad PROMise?; Should we learn how to do endoscopic carpal tunnel release?; Two-week radiographs a relic of the past?; Bible? Aspirate or excise?; Patient expectations and trapeziometacarpal osteoarthritis; Splintage in the treatment of sagittal band incompetence and extensor tendon subluxation
Clinical studies evaluating the effects of vitamin D alone or in combination with calcium on physical function, falls and fractures have been inconsistent. Vitamin D has, however, been the focus of much orthopaedic, trauma and endocrine research. Playing a central role in muscle and bone metabolism, some studies on Vitamin D therapies offer the tantalising suggestion of a reduction in falls and fractures simply with vitamin D supplementation. We review the background and evidence behind vitamin D.
We undertook a retrospective comparative study
of all patients with an unstable slipped capital femoral epiphysis presenting
to a single centre between 1998 and 2011. There were 45 patients
(46 hips; mean age 12.6 years; 9 to 14); 16 hips underwent intracapsular
cuneiform osteotomy and 30 underwent pinning Pinning Non-emergency intracapsular osteotomy may have a protective effect
on the epiphyseal vasculature and should be undertaken with a delay
of at least two weeks. The place of emergency pinning Cite this article:
The aim of our study was to describe the characteristics,
treatment, and outcomes of patients with periprosthetic joint infection
(PJI) and normal inflammatory markers after total knee arthroplasty
(TKA) and total hip arthroplasty (THA). In total 538 TKAs and 414 THAs underwent surgical treatment for
PJI and met the inclusion criteria. Pre-operative erythrocyte sedimentation
rate (ESR) and C-reactive protein level (CRP) were reviewed to identify
the seronegative cohort. An age- and gender-matched cohort was identified
from the remaining patients for comparison. Overall, 4% of confirmed
infections were seronegative (21 TKA and 17 THA). Of those who underwent
pre-operative aspiration, cultures were positive in 76% of TKAs
(n = 13) and 64% of THAs (n = 7). Cell count and differential were
suggestive of infection in 85% of TKA (n = 11) and all THA aspirates
(n = 5). The most common organism was coagulase-negative Cite this article:
Little information is available about several
important aspects of the treatment of melioidosis osteomyelitis
and septic arthritis. We undertook a retrospective review of 50 patients with these
conditions in an attempt to determine the effect of location of
the disease, type of surgical intervention and duration of antibiotic
treatment on outcome, particularly complications and relapse. We found that there was a 27.5% risk of osteomyelitis of the
adjacent bone in patients with septic arthritis in the lower limb.
Patients with septic arthritis and osteomyelitis of an adjacent
bone were in hospital significantly longer (p = 0.001), needed more
operations (p = 0.031) and had a significantly higher rate of complications
and re-presentation (p = 0.048). More than half the patients (61%), most particularly those with
multifocal bone and joint involvement, and those with septic arthritis
and osteomyelitis of an adjacent bone who were treated operatively,
needed more visits to theatre. Cite this article:
Charcot neuro-osteoarthropathy (CN) of the midfoot
presents a major reconstructive challenge for the foot and ankle
surgeon. The Synthes 6 mm Midfoot Fusion Bolt is both designed and
recommended for patients who have a deformity of the medial column
of the foot due to CN. We present the results from the first nine
patients (ten feet) on which we attempted to perform fusion of the
medial column using this bolt. Six feet had concurrent hindfoot fusion
using a retrograde nail. Satisfactory correction of deformity of
the medial column was achieved in all patients. The mean correction
of calcaneal pitch was from 6°
(-15° to +18°) pre-operatively to 16° (7° to 23°) post-operatively;
the mean Meary angle from 26° (3° to 46°) to 1° (1° to 2°); and
the mean talometatarsal angle on dorsoplantar radiographs from 27°
(1° to 48°) to 1° (1° to 3°). However, in all but two feet, at least one joint failed to fuse.
The bolt migrated in six feet, all of which showed progressive radiographic
osteolysis, which was considered to indicate loosening. Four of
these feet have undergone a revision procedure, with good radiological
evidence of fusion. The medial column bolt provided satisfactory correction
of the deformity but failed to provide adequate fixation for fusion
in CN deformities in the foot. In its present form, we cannot recommend the routine use of this
bolt. Cite this article:
In this retrospective study, we investigated
the results of revision total hip replacement (THR) using a cemented long-stemmed
Exeter femoral component, with a minimum length of 205 mm in patients
with extensive femoral bone defects. The study included 37 consecutive
patients with a mean age of 76 years (39 to 93) and a mean follow-up
of nine years (5 to 16). A total of 26 patients (70%) had a pre-operative
Endo-Klinik score of 3 or 4. Impaction bone grafting was used in
24 patients (65%). At the time of evaluation, 22 patients (59%)
were still alive and were evaluated clinically and radiologically.
A total of 14 patients died during follow-up and their data were
included until the time of their death. One reconstruction failed
after five years and five months owing to recurrent dislocation:
the hip was converted to an excision arthroplasty. Intra-operative
fractures or fissures were encountered in nine patients (24%), but
none occurred during impaction of the bone graft. Post-operative
peri-prosthetic fractures occurred in two patients (5%); both were
treated with plate fixation. At nine years, survival with the endpoint
of all-cause re-revision was 96.3% (95% CI 76.4 to 99.5); including
re-operations for any reason, it was 80.7% (95% CI 56.3 to 92.3%).
There were no re-revisions for aseptic loosening. The survival of long stem cemented femoral components following
revision THR is satisfactory in a fragile population with extensive
femoral defects. Cite this article:
The October 2014 Research Roundup360 looks at: unpicking syndesmotic injuries: CT scans evaluated; surgical scrub suits and sterility in theatre; continuous passive motion and knee injuries; whether pain at night is melatonin related;
Although the vast majority of patients that undergo
total knee replacement have satisfactory outcomes with a generally
low complication rate, occasionally a patient will be encountered
that has had multiple failed surgeries, and now reaches a crossroad
as to whether limb salvage will be acceptable or not. Cite this article:
The December 2015 Spine Roundup360 looks at: Ketamine in scoliosis surgery; Teriparatide in osteoporotic spinal fractures; Trabecular metal in the spine?; Revision surgery a SPORTing chance?; The course of degenerative lumbar spondylolisthesis; Hip or lumbar spine: a common conundrum
The December 2015 Trauma Roundup360 looks at: Delay to surgery in hip fracture; Hexapod fixators in the management of hypertrophic tibial nonunions; Thromboembolism after nailing pathological fractures; Tibial plateau fracture patterns under the spotlight; The health economic effects of long bone nonunion; Adverse outcomes in trauma; The sacral screw in children; Treating the contralateral SUFE
We present a case series of ten metal-on-polyethylene total hip
arthroplasties (MoP THAs) with delayed dislocation associated with
unrecognised adverse local tissue reaction due to corrosion at the
trunnion and pseudotumour formation. The diagnosis was not suspected in nine of the ten patients (six
female/four male; mean age 66 years), despite treatment in a specialist
unit (mean time from index surgery to revision was 58 months, 36
to 84). It was identified at revision surgery and subsequently confirmed
by histological examination of resected tissue. Pre-operative assessment
and culture results ruled out infection. A variety of treatment
strategies were used, including resection of the pseudotumour and
efforts to avoid recurrent dislocation. Aims
Methods
The June 2014 Knee Roundup360 looks at: acute repair preferable in hamstring ruptures; osteoarthritis a given in ACL injury, even with reconstruction?; chicken and egg: patellofemoral dysfunction and hip weakness; meniscal root tears as bad as we thought; outcomes in the meniscus; topical NSAIDs have a measurable effect on synovitis; nailing for tibial peri-prosthetic fracture.
The April 2015 Foot &
Ankle Roundup360 looks at: Plantar pressures linked to radiographs; Strength training for ankle instability?; Is weight loss good for your feet?; Diabetes and foot surgery complications; Tantalum for failed ankle arthroplasty?; Steroids, costs and Morton’s neuroma; Ankle arthritis and subtalar joint
The aim of this review is to address controversies
in the management of dislocations of the acromioclavicular joint. Current
evidence suggests that operative rather than non-operative treatment
of Rockwood grade III dislocations results in better cosmetic and
radiological results, similar functional outcomes and longer time
off work. Early surgery results in better functional and radiological
outcomes with a reduced risk of infection and loss of reduction compared
with delayed surgery. Surgical options include acromioclavicular fixation, coracoclavicular
fixation and coracoclavicular ligament reconstruction. Although
non-controlled studies report promising results for arthroscopic
coracoclavicular fixation, there are no comparative studies with
open techniques to draw conclusions about the best surgical approach.
Non-rigid coracoclavicular fixation with tendon graft or synthetic
materials, or rigid acromioclavicular fixation with a hook plate,
is preferable to fixation with coracoclavicular screws owing to
significant risks of loosening and breakage. The evidence, although limited, also suggests that anatomical
ligament reconstruction with autograft or certain synthetic grafts
may have better outcomes than non-anatomical transfer of the coracoacromial
ligament. It has been suggested that this is due to better restoration
horizontal and vertical stability of the joint. Despite the large number of recently published studies, there
remains a lack of high-quality evidence, making it difficult to
draw firm conclusions regarding these controversial issues. Cite this article:
This study aimed to determine the long-term functional,
clinical and radiological outcomes in patients with Schatzker IV
to VI fractures of the tibial plateau treated with an Ilizarov frame.
Clinical, functional and radiological assessment was carried out
at a minimum of one year post-operatively. A cohort of 105 patients
(62 men, 43 women) with a mean age of 49 years (15 to 87) and a
mean follow-up of 7.8 years (1 to 19) were reviewed. There were
18 type IV, 10 type V and 77 type VI fractures. All fractures united
with a mean time to union of 20.1 weeks (10.6 to 42.3). No patient
developed a deep infection. The median range of movement (ROM) of
the knee was 110o and the median Iowa score was 85. Our study demonstrates good long-term functional outcome with
no deep infection; spanning the knee had no detrimental effect on
the ROM or functional outcome. High-energy fractures of the tibial plateau may be treated effectively