Advertisement for orthosearch.org.uk
Results 121 - 140 of 190
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 195 - 200
1 Feb 2014
Abolghasemian M Tangsaraporn S Drexler M Barbuto R Backstein D Safir O Kuzyk P Gross A

The use of ilioischial cage reconstruction for pelvic discontinuity has been replaced by the Trabecular Metal (Zimmer, Warsaw, Indiana) cup-cage technique in our institution, due to the unsatisfactory outcome of using a cage alone in this situation. We report the outcome of 26 pelvic discontinuities in 24 patients (20 women and four men, mean age 65 years (44 to 84)) treated by the cup-cage technique at a mean follow-up of 82 months (12 to 113) and compared them with a series of 19 pelvic discontinuities in 19 patients (18 women and one man, mean age 70 years (42 to 86)) treated with a cage at a mean follow-up of 69 months (1 to 170). The clinical and radiological outcomes as well as the survivorship of the groups were compared. In all, four of the cup-cage group (15%) and 13 (68%) of the cage group failed due to septic or aseptic loosening. The seven-year survivorship was 87.2% (95% confidence interval (CI) 71 to 103) for the cup-cage group and 49.9% (95% CI 15 to 84) for the cage-alone group (p = 0.009). There were four major complications in the cup-cage group and nine in the cage group. Radiological union of the discontinuity was found in all successful cases in the cup-cage group and three of the successful cage cases. Three hips in the cup-cage group developed early radiological migration of the components, which stabilised with a successful outcome.

Cup-cage reconstruction is a reliable technique for treating pelvic discontinuity in mid-term follow-up and is preferred to ilioischial cage reconstruction. If the continuity of the bone graft at the discontinuity site is not disrupted, early migration of the components does not necessarily result in failure.

Cite this article: Bone Joint J 2014;96-B:195–200.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 263 - 269
1 Feb 2014
Batta V Coathup MJ Parratt MT Pollock RC Aston WJ Cannon SR Skinner JA Briggs TW Blunn GW

We reviewed the outcome of 69 uncemented, custom-made, distal femoral endoprosthetic replacements performed in 69 patients between 1994 and 2006. There were 31 women and 38 men with a mean age at implantation of 16.5 years (5 to 37). All procedures were performed for primary malignant bone tumours of the distal femur. At a mean follow-up of 124.2 months (4 to 212), 53 patients were alive, with one patient lost to follow-up. All nine implants (13.0%) were revised due to aseptic loosening at a mean of 52 months (8 to 91); three implants (4.3%) were revised due to fracture of the shaft of the prosthesis and three patients (4.3%) had a peri-prosthetic fracture. Bone remodelling associated with periosteal cortical thinning adjacent to the uncemented intramedullary stem was seen in 24 patients but this did not predispose to failure. All aseptically loose implants in this series were diagnosed to be loose within the first five years.

The results from this study suggest that custom-made uncemented distal femur replacements have a higher rate of aseptic loosening compared to published results for this design when used with cemented fixation. Loosening of uncemented replacements occurs early indicating that initial fixation of the implant is crucial.

Cite this article: Bone Joint J 2014;96-B:263–9.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1640 - 1644
1 Dec 2013
Agarwal S Azam A Morgan-Jones R

Bone loss in the proximal tibia and distal femur is frequently encountered in revision knee replacement surgery. The various options for dealing with this depend on the extent of any bone loss. We present our results with the use of cementless metaphyseal metal sleeves in 103 patients (104 knees) with a mean follow-up of 43 months (30 to 65). At final follow-up, sleeves in 102 knees had good osseointegration. Two tibial sleeves were revised for loosening, possibly due to infection.

The average pre-operative Oxford Knee Score was 23 (11 to 36) and this improved to 32 (15 to 46) post-operatively. These early results encourage us to continue with the technique and monitor the outcomes in the long term.

Cite this article: Bone Joint J 2013;95-B:1640–4.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1160 - 1164
1 Sep 2011
Jowett CR Morcuende JA Ramachandran M

We present a systematic review of the results of the Ponseti method of management for congenital talipes equinovarus (CTEV). Our aims were to assess the method, the effects of modifications to the original method, and compare it with other similar methods of treatment. We found 308 relevant citations in the English literature up to 31 May 2010, of which 74 full-text articles met our inclusion criteria. Our results showed that the Ponseti method provides excellent results with an initial correction rate of around 90% in idiopathic feet. Non-compliance with bracing is the most common cause of relapse. The current best practice for the treatment of CTEV is the original Ponseti method, with minimal adjustments being hyperabduction of the foot in the final cast and the need for longer-term bracing up to four years. Larger comparative studies will be required if other methods are to be recommended.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 732 - 737
1 Jun 2013
Kosuge D Yamada N Azegami S Achan P Ramachandran M

The term developmental dysplasia of the hip (DDH) describes a spectrum of disorders that results in abnormal development of the hip joint. If not treated successfully in childhood, these patients may go on to develop hip symptoms and/or secondary osteoarthritis in adulthood. In this review we describe the altered anatomy encountered in adults with DDH along with the management options, and the challenges associated with hip arthroscopy, osteotomies and arthroplasty for the treatment of DDH in young adults.

Cite this article: Bone Joint J 2013;95-B:732–7.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1600 - 1609
1 Dec 2014
Matharu GS Pynsent PB Sumathi VP Mittal S Buckley CD Dunlop DJ Revell PA Revell MP

We undertook a retrospective cohort study to determine clinical outcomes following the revision of metal-on-metal (MoM) hip replacements for adverse reaction to metal debris (ARMD), and to identify predictors of time to revision and outcomes following revision. Between 1998 and 2012 a total of 64 MoM hips (mean age at revision of 57.8 years; 46 (72%) female; 46 (72%) hip resurfacings and 18 (28%) total hip replacements) were revised for ARMD at one specialist centre. At a mean follow-up of 4.5 years (1.0 to 14.6) from revision for ARMD there were 13 hips (20.3%) with post-operative complications and eight (12.5%) requiring re-revision.

The Kaplan–Meier five-year survival rate for ARMD revision was 87.9% (95% confidence interval 78.9 to 98.0; 19 hips at risk). Excluding re-revisions, the median absolute Oxford hip score (OHS) following ARMD revision using the percentage method (0% best outcome and 100% worst outcome) was 18.8% (interquartile range (IQR) 7.8% to 48.3%), which is equivalent to 39/48 (IQR 24.8/48 to 44.3/48) when using the modified OHS. Histopathological response did not affect time to revision for ARMD (p = 0.334) or the subsequent risk of re-revision (p = 0.879). Similarly, the presence or absence of a contralateral MoM hip bearing did not affect time to revision for ARMD (p = 0.066) or the subsequent risk of re-revision (p = 0.178).

Patients revised to MoM bearings had higher rates of re-revision (five of 16 MoM hips re-revised; p = 0.046), but those not requiring re-revision had good functional results (median absolute OHS 14.6% or 41.0/48). Short-term morbidity following revision for ARMD was comparable with previous reports. Caution should be exercised when choosing bearing surfaces for ARMD revisions.

Cite this article: Bone Joint J 2014;96-B:1600–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1148 - 1150
1 Aug 2012
Nakamura Y Ohishi H Kishiya M Toh S

Although good to excellent short-term results of arthroscopic partial limbectomy of the hip have been reported, there is little information on the long-term outcome of the procedure. We report a case with a 16-year follow-up.

A 34-year old woman presented with a three-month history of severe pain and limitation of movement of the hip. Plain radiographs and arthrography showed no abnormality. MRI showed an effusion and a deformity of the anterosuperior part of the labrum. This was confirmed as an inverted labral tear that was debrided arthroscopically.

At 16 years post-operatively, she remained symptom-free. Plain radiographs showed no abnormality and MRI suggested that the sealing effect of the scar tissue prevented articular damage and degeneration.


Bone & Joint 360
Vol. 1, Issue 5 | Pages 28 - 30
1 Oct 2012

The October 2012 Children’s orthopaedics Roundup360 looks at: magnetic growing rods and scoliosis correction; maintaining alignment after manipulation of a radial shaft fracture; Glaswegian children and swellings of obscure origin; long-term outcome of femoral derotation osteotomy in cerebral palsy; lower-leg fractures and compartment syndrome in children; fractures of the radial neck in children; management of the paediatric Monteggia fracture; and missing the dislocated hip in Western Australia.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1356 - 1361
1 Oct 2012
Streit MR Walker T Bruckner T Merle C Kretzer JP Clarius M Aldinger PR Gotterbarm T

The Oxford mobile-bearing unicompartmental knee replacement (UKR) is an effective and safe treatment for osteoarthritis of the medial compartment. The results in the lateral compartment have been disappointing due to a high early rate of dislocation of the bearing. A series using a newly designed domed tibial component is reported.

The first 50 consecutive domed lateral Oxford UKRs in 50 patients with a mean follow-up of three years (2.0 to 4.3) were included. Clinical scores were obtained prospectively and Kaplan-Meier survival analysis was performed for different endpoints. Radiological variables related to the position and alignment of the components were measured.

One patient died and none was lost to follow-up. The cumulative incidence of dislocation was 6.2% (95% confidence interval (CI) 2.0 to 17.9) at three years. Survival using revision for any reason and aseptic revision was 94% (95% CI 82 to 98) and 96% (95% CI 85 to 99) at three years, respectively. Outcome scores, visual analogue scale for pain and maximum knee flexion showed a significant improvement (p < 0.001). The mean Oxford knee score was 43 (sd 5.3), the mean Objective American Knee Society score was 91 (sd 13.9) and the mean Functional American Knee Society score was 90 (sd 17.5). The mean maximum flexion was 127° (90° to 145°). Significant elevation of the lateral joint line as measured by the proximal tibial varus angle (p = 0.04) was evident in the dislocation group when compared with the non-dislocation group.

Clinical results are excellent and short-term survival has improved when compared with earlier series. The risk of dislocation remains higher using a mobile-bearing UKR in the lateral compartment when compared with the medial compartment. Patients should be informed about this complication. To avoid dislocations, care must be taken not to elevate the lateral joint line.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 899 - 905
1 Jul 2008
Dias JJ Dhukaram V Abhinav A Bhowal B Wildin CJ

We report the outcome at a mean of 93 months (73 to 110) of 71 patients with an acute fracture of the scaphoid who were randomised to Herbert screw fixation (35) or below-elbow plaster cast immobilisation (36). These 71 patients represent the majority of a randomised series of 88 patients whose short-term outcome has previously been reported. Those patients available for later review were similar in age, gender and hand dominance.

There was no statistical difference in symptoms and disability as assessed by the mean Patient Evaluation Measure (p = 0.4), or mean Patient-Rated Wrist Evaluation (p = 0.9), the mean range of movement of the wrist (p = 0.4), mean grip strength (p = 0.8), or mean pinch strength (p = 0.4).

Radiographs were available from the final review for 59 patients. Osteoarthritic changes were seen in the scaphotrapezial and radioscaphoid joints in eight (13.5%) and six patients (10.2%), respectively. Three patients had asymptomatic lucency surrounding the screw. One non-operatively treated patient developed nonunion with avascular necrosis. In five patients who were treated non-operatively (16%) there was an abnormal scapholunate angle ( > 60°), but in four of these patients this finding was asymptomatic.

No medium-term difference in function or radiological outcome was identified between the two treatment groups.


Bone & Joint Research
Vol. 2, Issue 2 | Pages 18 - 25
1 Feb 2013
Kon E Filardo G Di Matteo B Perdisa F Marcacci M

Objectives

Matrix-assisted autologous chondrocyte transplantation (MACT) has been developed and applied in the clinical practice in the last decade to overcome most of the disadvantages of the first generation procedures. The purpose of this systematic review is to document and analyse the available literature on the results of MACT in the treatment of chondral and osteochondral lesions of the knee.

Methods

All studies published in English addressing MACT procedures were identified, including those that fulfilled the following criteria: 1) level I-IV evidence, 2) measures of functional or clinical outcome, 3) outcome related to cartilage lesions of the knee cartilage.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1540 - 1545
1 Nov 2012
Reigstad O Lütken T Grimsgaard C Bolstad B Thorkildsen R Røkkum M

The Motec cementless modular metal-on-metal ball-and-socket wrist arthroplasty was implanted in 16 wrists with scaphoid nonunion advanced collapse (SNAC; grades 3 or 4) and 14 wrists with scapholunate advanced collapse (SLAC) in 30 patients (20 men) with severe (grades 3 or 4) post-traumatic osteoarthritis of the wrist. The mean age of the patients was 52 years (31 to 71). All prostheses integrated well radiologically. At a mean follow-up of 3.2 years (1.1 to 6.1) no luxation or implant breakage occurred. Two wrists were converted to an arthrodesis for persistent pain. Loosening occurred in one further wrist at five years post-operatively. The remainder demonstrated close bone–implant contact. The clinical results were good, with markedly decreased Disabilities of the Arm Shoulder and Hand (DASH) and pain scores, and increased movement and grip strength. No patient used analgesics and most had returned to work.

Good short-term function was achieved using this wrist arthroplasty in a high-demand group of patients with post-traumatic osteoarthritis.


Bone & Joint 360
Vol. 1, Issue 4 | Pages 17 - 19
1 Aug 2012

The August 2012 Wrist & Hand Roundup360 looks at: the Herbert ulnar head prosthesis; the five-year outcome for wrist arthroscopic surgery; four-corner arthrodesis with headless screws; balloon kyphoplasty for Kienböck's disease; Mason Type 2 radial head fractures; local infiltration and intravenous regional anaesthesia for endoscopic carpal tunnel release; perilunate injuries; and replanting the amputated fingertip.


Bone & Joint 360
Vol. 1, Issue 4 | Pages 29 - 31
1 Aug 2012

The August 2012 Children’s orthopaedics Roundup360 looks at: whether 3D-CT gives a better idea of coverage than plain radiographs; forearm fractures after trampolining accidents; forearm fractures and the Rush pin; the fractured distal radius; elastic stable intramedullary nailing for long-bone fractures; aponeurotic recession for the equinus foot; the torn medial patellofemoral ligament and the adductor tubercle; slipped capital femoral epiphysis; paediatric wrist arthroscopy; and Pirani scores and clubfoot.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1143 - 1147
1 Aug 2012
Svehlík M Kraus T Steinwender G Zwick EB Saraph V Linhart WE

Although equinus gait is the most common abnormality in children with spastic cerebral palsy (CP) there is no consistency in recommendations for treatment, and evidence for best practice is lacking. The Baumann procedure allows selective fractional lengthening of the gastrocnemii and soleus muscles but the long-term outcome is not known. We followed a group of 18 children (21 limbs) with diplegic CP for ten years using three-dimensional instrumented gait analysis. The kinematic parameters of the ankle joint improved significantly following this procedure and were maintained until the end of follow-up. We observed a normalisation of the timing of the key kinematic and kinetic parameters, and an increase in the maximum generation of power of the ankle. There was a low rate of overcorrection (9.5%, n = 2), and a rate of recurrent equinus similar to that found with other techniques (23.8%, n = 5).

As the procedure does not impair the muscle architecture, and allows for selective correction of the contracted gastrocnemii and soleus, it may be recommended as the preferred method for correction of a mild fixed equinus deformity.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 16 - 19
1 Jun 2012

The June 2012 Wrist & Hand Roundup360 looks at; radial osteotomy and advanced Kienböck's disease; fixing the Bennett fracture; PEEK plates and four-corner arthrodesis,;carpal tunnel release and haemodialysis; degloved digits and the reverse radial forearm flap; occupational hand injuries; trapeziometacarpal osteoarthritis; fixing the fractured metacarpal neck and pyrocarbon implants for the destroyed PIPJ.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1557 - 1566
1 Dec 2006
Khanduja V Villar RN

This review describes the development of arthroscopy of the hip over the past 15 years with reference to patient assessment and selection, the technique, the conditions for which it is likely to prove useful, the contraindications and complications related to the procedure and, finally, to discuss possible developments in the future.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1650 - 1655
1 Dec 2013
van Bergen CJA van Eekeren ICM Reilingh ML Sierevelt IN van Dijk CN

We have evaluated the clinical effectiveness of a metal resurfacing inlay implant for osteochondral defects of the medial talar dome after failed previous surgical treatment. We prospectively studied 20 consecutive patients with a mean age of 38 years (20 to 60), for a mean of three years (2 to 5) post-surgery. There was statistically significant reduction of pain in each of four situations (i.e., rest, walking, stair climbing and running; p ≤ 0.01). The median American Orthopaedic Foot and Ankle Society ankle-hindfoot score improved from 62 (interquartile range (IQR) 46 to 72) pre-operatively to 87 (IQR 75 to 95) at final follow-up (p < 0.001). The Foot and Ankle Outcome Score improved on all subscales (p ≤ 0.03). The mean Short-Form 36 physical component scale improved from 36 (23 to 50) pre-operatively to 45 (29 to 55) at final follow-up (p = 0.001); the mental component scale did not change significantly. On radiographs, progressive degenerative changes of the opposing tibial plafond were observed in two patients. One patient required additional surgery for the osteochondral defect. This study shows that a metal implant is a promising treatment for osteochondral defects of the medial talar dome after failed previous surgery.

Cite this article: Bone Joint J 2013;95-B:1650–5.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1296 - 1299
1 Oct 2011
Lang JE Mannava S Floyd AJ Goddard MS Smith BP Mofidi A M. Seyler T Jinnah RH

Robots have been used in surgery since the late 1980s. Orthopaedic surgery began to incorporate robotic technology in 1992, with the introduction of ROBODOC, for the planning and performance of total hip replacement. The use of robotic systems has subsequently increased, with promising short-term radiological outcomes when compared with traditional orthopaedic procedures. Robotic systems can be classified into two categories: autonomous and haptic (or surgeon-guided). Passive surgery systems, which represent a third type of technology, have also been adopted recently by orthopaedic surgeons.

While autonomous systems have fallen out of favour, tactile systems with technological improvements have become widely used. Specifically, the use of tactile and passive robotic systems in unicompartmental knee replacement (UKR) has addressed some of the historical mechanisms of failure of non-robotic UKR. These systems assist with increasing the accuracy of the alignment of the components and produce more consistent ligament balance. Short-term improvements in clinical and radiological outcomes have increased the popularity of robot-assisted UKR.

Robot-assisted orthopaedic surgery has the potential for improving surgical outcomes. We discuss the different types of robotic systems available for use in orthopaedics and consider the indication, contraindications and limitations of these technologies.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1328 - 1333
1 Oct 2008
Jackson WFM van der Tempel WM Salmon LJ Williams HA Pinczewski LA

We evaluated the long-term outcome of isolated endoscopically-assisted posterior cruciate ligament reconstruction in 26 patients using hamstring tendon autografts after failure of conservative management. At ten years after surgery the mean International Knee Documentation Committee subjective knee score was 87 (sd 14) of a possible 100 points. Regular participation in moderate to strenuous activities was possible for only seven patients pre-operatively; this increased to 23 patients post-operatively. The mean Lysholm score improved from 64 (sd 15) to 90 (sd 14) at ten years (p = 0.001).

At ten years endoscopic reconstruction of the posterior cruciate ligament with hamstring tendon autograft is effective in reducing knee symptoms. Of the series, 22 patients underwent radiological assessment for the development of osteoarthritis using the Kellgren-Lawrence grading scale. In four patients, grade 2 changes with loss of joint space was observed and another four patients showed osteophyte formation with moderate joint space narrowing (grade 3). These findings compared favourably with non-operatively managed injuries of the posterior cruciate ligament.

This procedure for symptomatic patients with posterior cruciate ligament laxity who have failed conservative management offers good results.