Advertisement for orthosearch.org.uk
Results 121 - 140 of 160
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 836 - 841
1 Jun 2012
Frisoni T Cevolani L Giorgini A Dozza B Donati DM

We retrospectively reviewed 101 consecutive patients with 114 femoral tumours treated by massive bone allograft at our institution between 1986 and 2005. There were 49 females and 52 males with a mean age of 20 years (4 to 74). At a median follow-up of 9.3 years (2 to 19.8), 36 reconstructions (31.5%) had failed. The allograft itself failed in 27 reconstructions (24%).

Mechanical complications such as delayed union, fracture and failure of fixation were studied. The most adverse factor on the outcome was the use of intramedullary nails, followed by post-operative chemotherapy, resection length > 17 cm and age > 18 years at the time of intervention. The simultaneous use of a vascularised fibular graft to protect the allograft from mechanical complications improved the outcome, but the use of intramedullary cementing was not as successful.

In order to improve the strength of the reconstruction and to advance the biology of host–graft integration, we suggest avoiding the use of intramedullary nails and titanium plates, but instead using stainless steel plates, as these gave better results. The use of a supplementary vascularised fibular graft should be strongly considered in adult patients with resection > 17 cm and in those who require post-operative chemotherapy.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 121 - 128
1 Jan 2015
Kang S Han I Hong SH Cho HS Kim W Kim H

Cancellous allograft bone chips are commonly used in the reconstruction of defects in bone after removal of benign tumours. We investigated the MRI features of grafted bone chips and their change over time, and compared them with those with recurrent tumour. We retrospectively reviewed 66 post-operative MRIs from 34 patients who had undergone curettage and grafting with cancellous bone chips to fill the defect after excision of a tumour. All grafts showed consistent features at least six months after grafting: homogeneous intermediate or low signal intensities with or without scattered hyperintense foci (speckled hyperintensities) on T1 images; high signal intensities with scattered hypointense foci (speckled hypointensities) on T2 images, and peripheral rim enhancement with or without central heterogeneous enhancements on enhanced images. Incorporation of the graft occurred from the periphery to the centre, and was completed within three years. Recurrent lesions consistently showed the same signal intensities as those of pre-operative MRIs of the primary lesions. There were four misdiagnoses, three of which were chondroid tumours.

We identified typical MRI features and clarified the incorporation process of grafted cancellous allograft bone chips. The most important characteristics of recurrent tumours were that they showed the same signal intensities as the primary tumours. It might sometimes be difficult to differentiate grafted cancellous allograft bone chips from a recurrent chondroid tumour.

Cite this article: Bone Joint J 2015;97-B:121–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 982 - 988
1 Jul 2012
Puri A Gulia A Jambhekar N Laskar S

We analysed the outcome of patients with primary non-metastatic diaphyseal sarcomas who had en bloc resection with preservation of the adjoining joints and reconstruction with re-implantation of sterilised tumour bone after extracorporeal radiation (50 Gy). Between March 2005 and September 2009, 32 patients (16 Ewing’s sarcoma and 16 osteogenic sarcoma) with a mean age of 15 years (2 to 35) underwent this procedure. The femur was the most common site in 17 patients, followed by the tibia in 11, humerus in three and ulna in one. The mean resected length of bone was 19 cm (10 to 26). A total of 31 patients were available at a mean follow-up of 34 months (12 to 74). The mean time to union for all osteotomy sites was 7.3 months (3 to 28): metaphyseal osteotomy sites united quicker than diaphyseal osteotomy sites (5.8 months (3 to 10) versus 9.5 months (4 to 28)). There were three local recurrences, all in soft-tissue away from irradiated graft. At the time of final follow-up, 19 patients were free of disease, one was alive with disease and 11 had died of disease. The mean Musculoskeletal Tumor Society Score for 29 patients evaluated at the last follow-up was 26 (9 to 30).

Extracorporeal irradiation is an oncologically safe and inexpensive technique for limb salvage in diaphyseal sarcomas and has good functional results.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1540 - 1545
1 Nov 2014
Dierselhuis EF van den Eerden PJM Hoekstra HJ Bulstra SK Suurmeijer AJH Jutte PC

Atypical cartilaginous tumours are usually treated by curettage. The purpose of this study was to show that radiofrequency ablation was an effective alternative treatment.

We enrolled 20 patients (two male, 18 female, mean age 56 years (36 to 72) in a proof-of-principle study. After inclusion, biopsy and radiofrequency ablation were performed, followed three months later by curettage and adjuvant phenolisation. The primary endpoint was the proportional necrosis in the retrieved material. Secondary endpoints were correlation with the findings on gadolinium enhanced MRI, functional outcome and complications.

Our results show that 95% to 100% necrosis was obtained in 14 of the 20 patients. MRI had a 91% sensitivity and 67% specificity for detecting residual tumour after curettage. The mean functional outcome (MSTS) score six weeks after radiofrequency ablation was 27.1 (23 to 30) compared with 18.1 (12 to 25) after curettage (p < 0.001). No complications occurred after ablation, while two patients developed a pathological fracture after curettage.

We have shown that radiofrequency ablation is capable of completely eradicating cartilaginous tumour cells in selective cases. MRI has a 91% sensitivity for detecting any residual tumour. Radiofrequency ablation can be performed on an outpatient basis allowing a rapid return to normal activities. If it can be made more effective, it has the potential to provide better local control, while improving functional outcome.

Cite this article: Bone Joint J 2014;96-B:1540–5.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1258 - 1263
1 Sep 2014
Schuh R Panotopoulos J Puchner SE Willegger M M. Hobusch G Windhager R Funovics PT

Resection of a primary sarcoma of the diaphysis of a long bone creates a large defect. The biological options for reconstruction include the use of a vascularised and non-vascularised fibular autograft.

The purpose of the present study was to compare these methods of reconstruction.

Between 1985 and 2007, 53 patients (26 male and 27 female) underwent biological reconstruction of a diaphyseal defect after resection of a primary sarcoma. Their mean age was 20.7 years (3.6 to 62.4). Of these, 26 (49 %) had a vascularised and 27 (51 %) a non-vascularised fibular autograft. Either method could have been used for any patient in the study. The mean follow-up was 52 months (12 to 259). Oncological, surgical and functional outcome were evaluated. Kaplan–Meier analysis was performed for graft survival with major complication as the end point.

At final follow-up, eight patients had died of disease. Primary union was achieved in 40 patients (75%); 22 (42%) with a vascularised fibular autograft and 18 (34%) a non-vascularised (p = 0.167). A total of 32 patients (60%) required revision surgery. Kaplan–Meier analysis revealed a mean survival without complication of 36 months (0.06 to 107.3, sd 9) for the vascularised group and 88 months (0.33 to 163.9, sd 16) for the non-vascularised group (p = 0.035).

Both groups seem to be reliable biological methods of reconstructing a diaphyseal bone defect. Vascularised autografts require more revisions mainly due to problems with wound healing in distal sites of tumour, such as the foot.

Cite this article: Bone Joint J 2014;96-B:1258–63.


Bone & Joint 360
Vol. 3, Issue 3 | Pages 32 - 34
1 Jun 2014

The June 2014 Oncology Roundup360 looks at: Infection still a problem in endoprosthetic reconstruction; massive allografts not as successful as we perhaps think; curopsy for aneurysmal bone cysts?; lengthening prosthesis: days are numbered; new WHO classification in brief; proximal tumours and fluid levels: bad news; infection is predictable in orthopaedic oncology; psychosocial support key in oncological outcomes.


Bone & Joint 360
Vol. 3, Issue 2 | Pages 22 - 24
1 Apr 2014

The April 2014 Oncology Roundup360 looks at: Eyeball as good as microscope for tumour margins; when is best to stabilise femoral metastases?; fluorine does not cause bone tumours; whether giant cell tumour of the proximal femur ever successfully managed; extraskeletal osteosarcoma; modular lower limb tumour reconstruction; and observational studies the basis for most bone tumour treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 521 - 526
1 Apr 2007
Myers GJC Abudu AT Carter SR Tillman RM Grimer RJ

We investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the distal femur after resection of a tumour. Survival of the implant and ‘servicing’ procedures have been documented using a prospective database, review of the design of the implant and case records. In total, 335 patients underwent a distal femoral replacement, 162 having a fixed-hinge design and 173 a rotating-hinge. The median age of the patients was 24 years (interquartile range 17 to 48).

A total of 192 patients remained alive with a mean follow-up of 12 years (5 to 30). The risk of revision for any reason was 17% at five years, 33% at ten years and 58% at 20 years. Aseptic loosening was the main reason for revision of the fixed-hinge knees while infection and fracture of the stem were the most common for the rotating-hinge implant. The risk of revision for aseptic loosening was 35% at ten years with the fixed-hinge knee, which has, however, been replaced by the rotating-hinge knee with a hydroxyapatite collar. The overall risk of revision for any reason fell by 52% when the rotating-hinge implant was used.

Improvements in the design of distal femoral endoprostheses have significantly decreased the need for revision operations, but infection remains a serious problem. We believe that a cemented, rotating-hinge prosthesis with a hydroxyapatite collar offers the best chance of long-term survival of the prosthesis.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 677 - 683
1 May 2014
Greenberg A Berenstein Weyel T Sosna J Applbaum J Peyser A

Osteoid osteoma is treated primarily by radiofrequency (RF) ablation. However, there is little information about the distribution of heat in bone during the procedure and its safety. We constructed a model of osteoid osteoma to assess the distribution of heat in bone and to define the margins of safety for ablation. Cavities were drilled in cadaver bovine bones and filled with a liver homogenate to simulate the tumour matrix. Temperature-sensing probes were placed in the bone in a radial fashion away from the cavities. RF ablation was performed 107 times in tumours < 10 mm in diameter (72 of which were in cortical bone, 35 in cancellous bone), and 41 times in cortical bone with models > 10 mm in diameter. Significantly higher temperatures were found in cancellous bone than in cortical bone (p <  0.05). For lesions up to 10 mm in diameter, in both bone types, the temperature varied directly with the size of the tumour (p < 0.05), and inversely with the distance from it. Tumours of > 10 mm in diameter showed a trend similar to those of smaller lesions. No temperature rise was seen beyond 12 mm from the edge of a cortical tumour of any size. Formulae were developed to predict the expected temperature in the bone during ablation.

Cite this article: Bone Joint J 2014; 96-B:677–83


Bone & Joint 360
Vol. 2, Issue 5 | Pages 34 - 36
1 Oct 2013

The October 2013 Oncology Roundup360 looks at: En bloc resection, irradiation and re-implantation; Metastasis and osteosarcoma; Mobile spine and osteosarcoma; Denosumab miraculous for GCT; Fevers, megaprostheses and sarcomas; PET and prognosis; Canine sarcomas not so different?; Bone cement and giant cell tumours.


Bone & Joint Research
Vol. 1, Issue 10 | Pages 272 - 280
1 Oct 2012
De Mattos CBR Binitie O Dormans JP

Pathological fractures in children can occur as a result of a variety of conditions, ranging from metabolic diseases and infection to tumours. Fractures through benign and malignant bone tumours should be recognised and managed appropriately by the treating orthopaedic surgeon. The most common benign bone tumours that cause pathological fractures in children are unicameral bone cysts, aneurysmal bone cysts, non-ossifying fibromas and fibrous dysplasia. Although pathological fractures through a primary bone malignancy are rare, these should be recognised quickly in order to achieve better outcomes. A thorough history, physical examination and review of plain radiographs are crucial to determine the cause and guide treatment. In most benign cases the fracture will heal and the lesion can be addressed at the time of the fracture, or after the fracture is healed. A step-wise and multidisciplinary approach is necessary in caring for paediatric patients with malignancies. Pathological fractures do not have to be treated by amputation; these fractures can heal and limb salvage can be performed when indicated.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1551 - 1555
1 Nov 2013
Kaa AKS Jørgensen PH Søjbjerg JO Johannsen HV

We investigated the functional outcome in patients who underwent reverse shoulder replacement (RSR) after removal of a tumour of the proximal humerus. A total of 16 patients (ten women and six men) underwent this procedure between 1998 and 2011 in our hospital. Five patients died and one was lost to follow-up. Ten patients were available for review at a mean follow-up of 46 months (12 to 136). Eight patients had a primary and two patients a secondary bone tumour.

At final follow up the mean range of active movement was: abduction 78° (30° to 150°); flexion 98° (45° to 180°); external rotation 32° (10° to 60°); internal rotation 51° (10° to 80°). The mean Musculoskeletal Tumor Society score was 77% (60% to 90%) and the mean Toronto Extremity Salvage Score was 70% (30% to 91%). Two patients had a superficial infection and one had a deep infection and underwent a two-stage revision procedure. In two patients there was loosening of the RSR; one dislocated twice. All patients had some degree of atrophy or pseudo-atrophy of the deltoid muscle.

Use of a RSR in patients with a tumour of the proximal humerus gives acceptable results.

Cite this article: Bone Joint J 2013;95-B:1551–5.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1632 - 1637
1 Dec 2007
Myers GJC Abudu AT Carter SR Tillman RM Grimer RJ

We have investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the proximal tibia following resection of a tumour. Survival of the implant and ‘servicing’ procedures have been documented using a prospective database.

A total of 194 patients underwent a proximal tibial replacement, with 95 having a fixed-hinge design and 99 a rotating-hinge with a hydroxyapatite collar; their median age was 21.5 years (10 to 74). At a mean follow-up of 14.7 years (5 to 29), 115 patients remain alive. The risk of revision for any reason in the fixed-hinge group was 32% at five years, 61% at ten years and 75% at 15 and 20 years, and in the rotating-hinge group 12% at five years, 25% at ten years and 30% at 15 years. Aseptic loosening was the most common reason for revision in the fixed-hinge knees, fracture of the implant in the early design of rotating hinges and infection in the current version. The risk of revision for aseptic loosening in the fixed-hinge knees was 46% at ten years. This was reduced to 3% in the rotating-hinge knee with a hydroxyapatite collar. The cemented, rotating hinge design currently offers the best chance of long-term survival of the prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1487 - 1491
1 Nov 2006
Ahlmann ER Menendez LR

Custom-made intercalary endoprostheses may be used for the reconstruction of diaphyseal defects following the resection of bone tumours. The aim of this study was to determine the survival of intercalary endoprostheses with a lap joint design, and to evaluate the clinical results, complications and functional outcome. We retrospectively reviewed six consecutive patients, three of whom underwent limb salvage with intercalary endoprostheses of the tibia, two of the femur, and one of the humerus. Their mean age was 42 years (28 to 64). The mean follow-up was 21.6 months (9 to 58). The humeral prosthesis required revision at 14 months owing to aseptic loosening. There were no implant-related failures. Musculoskeletal Tumour Society functional outcome scores indicated that patients achieved 90% of premorbid function.

Custom intercalary endoprostheses result in reconstructions comparable with, if not better than, those of allografts. Using this design of implant reduces the incidence of early complications and difficulties experienced with previous versions.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1234 - 1238
1 Sep 2007
Foster L Dall GF Reid R Wallace WH Porter DE

We have reviewed the data from our regional Bone Tumour Registry on patients with osteosarcoma diagnosed between 1933 and 2004 in order to investigate the relationship between survival and changes in treatment. There were 184 patients with non-metastatic appendicular osteosarcoma diagnosed at the age of 18 or under. Survival was calculated using Kaplan-Meier curves, and multivariate analysis was performed using the Cox regression proportional hazards model.

The five-year survival improved from 21% between 1933 and 1959, to 62% between 1990 and 1999. During this time, a multi-disciplinary organisation was gradually developed to manage treatment. The most significant variable affecting outcome was the date of diagnosis, with trends in improved survival mirroring the introduction of increasingly effective chemotherapy. Our experience suggests that the guidelines of the National Institute for Clinical Excellence on the minimum throughput of centres for treatment should be enforced flexibly in those that can demonstrate that their historical and contemporary results are comparable to those published nationally and internationally.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 707 - 712
1 May 2010
Siegel HJ Lopez-Ben R Mann JP Ponce BA

Bone loss secondary to primary or metastatic lesions of the proximal humerus remains a challenging surgical problem. Options include preservation of the joint with stabilisation using internal fixation or resection of the tumour with prosthetic replacement. Resection of the proximal humerus often includes the greater tuberosity and adjacent diaphysis, which may result in poor function secondary to loss of the rotator cuff and/or deltoid function. Preservation of the joint with internal fixation may reduce the time in hospital and peri-operative morbidity compared with joint replacement, and result in a better functional outcome. We included 32 patients with pathological fractures of the proximal humerus in this study. Functional and radiological assessments were performed. At a mean follow-up of 17.6 months (8 to 61) there was no radiological evidence of failure of fixation. The mean revised musculoskeletal Tumour Society functional score was 94.6% (86% to 99%). There was recurrent tumour requiring further surgery in four patients (12.5%). Of the 22 patients who were employed prior to presentation all returned to work without restrictions.

The use of a locking plate combined with augmentation with cement extends the indications for salvage of the proximal humerus with good function in patients with pathological and impending pathological fractures.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 838 - 845
1 Jun 2013
Oliveira VC van der Heijden L van der Geest ICM Campanacci DA Gibbons CLMH van de Sande MAJ Dijkstra PDS

Giant cell tumours (GCTs) of the small bones of the hands and feet are rare. Small case series have been published but there is no consensus about ideal treatment. We performed a systematic review, initially screening 775 titles, and included 12 papers comprising 91 patients with GCT of the small bones of the hands and feet. The rate of recurrence across these publications was found to be 72% (18 of 25) in those treated with isolated curettage, 13% (2 of 15) in those treated with curettage plus adjuvants, 15% (6 of 41) in those treated by resection and 10% (1 of 10) in those treated by amputation.

We then retrospectively analysed 30 patients treated for GCT of the small bones of the hands and feet between 1987 and 2010 in five specialised centres. The primary treatment was curettage in six, curettage with adjuvants (phenol or liquid nitrogen with or without polymethylmethacrylate (PMMA)) in 18 and resection in six. We evaluated the rate of complications and recurrence as well as the factors that influenced their functional outcome.

At a mean follow-up of 7.9 years (2 to 26) the rate of recurrence was 50% (n = 3) in those patients treated with isolated curettage, 22% (n = 4) in those treated with curettage plus adjuvants and 17% (n = 1) in those treated with resection (p = 0.404). The only complication was pain in one patient, which resolved after surgical removal of remnants of PMMA. We could not identify any individual factors associated with a higher rate of complications or recurrence. The mean post-operative Musculoskeletal Tumor Society scores were slightly higher after intra-lesional treatment including isolated curettage and curettage plus adjuvants (29 (20 to 30)) compared with resection (25 (15 to 30)) (p = 0.091). Repeated curettage with adjuvants eventually resulted in the cure for all patients and is therefore a reasonable treatment for both primary and recurrent GCT of the small bones of the hands and feet.

Cite this article: Bone Joint J 2013;95-B:838–45.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 974 - 978
1 Jul 2005
Suneja R Grimer RJ Belthur M Jeys L Carter SR Tillman RM Davies AM

We undertook this retrospective study to determine the rate of recurrence and functional outcome after intralesional curettage for chondroblastoma of bone. The factors associated with aggressive behaviour of the tumour were also analysed. We reviewed 53 patients with histologically-proven chondroblastoma who were treated by intralesional curettage in our unit between 1974 and 2000. They were followed up for at least two years to a maximum of 27 years.

Seven (13.2%) had a histologically-proven local recurrence. Three underwent a second intralesional curettage and had no further recurrence. Two had endoprosthetic replacement of the proximal humerus and two underwent below-knee amputation after aggressive local recurrence. One patient had the rare malignant metastatic chondroblastoma and eventually died. The mean Musculoskeletal Tumour Society functional score of the survivors was 94.2%.

We conclude that meticulous intralesional curettage alone can achieve low rates of local recurrence and excellent long-term function.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1366 - 1372
1 Oct 2009
Abed YY Beltrami G Campanacci DA Innocenti M Scoccianti G Capanna R

We reviewed 25 patients who had undergone resection of a primary bone sarcoma which extended to within 5 cm of the knee with reconstruction by a combination of a free vascularised fibular graft and a massive allograft bone shell. The distal femur was affected in four patients and the proximal tibia in 21. Their mean age at the time of operation was 19.7 years (5 to 52) and the mean follow-up period 140 months (28 to 213). Three vascularised transfers failed. The mean time to union of the fibula was 5.6 months (3 to 10) and of the allograft 19.6 months (10 to 34). Full weight-bearing was allowed at a mean of 21.4 months (14 to 36). The mean functional score at final follow-up was 27.4 (18 to 30) using a modfied 30-point Musculoskeletal Tumour Society rating system. The overall limb-salvage rate was 88%. The results of our study suggest that the combined use of a vascularised fibular graft and allograft is of value as a limb-salvage procedure for intercalary reconstruction after resection of bone tumours around the knee, especially in skeletally immature patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 395 - 400
1 Mar 2009
Krieg AH Mani M Speth BM Stalley PD

We review the treatment of pelvic Ewing’s sarcoma by the implantation of extracorporeally-irradiated (ECI) autografts and compare the outcome with that of other reported methods.

We treated 13 patients with ECI autografts between 1994 and 2004. There were seven males and six females with a median age of 15.7 years (interquartile range (IQR) 12.2 to 21.7). At a median follow-up of five years (IQR 1.8 to 7.4), the disease-free survival was 69% overall, and 75% if one patient with local recurrence after initial treatment elsewhere was excluded. Four patients died from distant metastases at a mean of 17 months (13 to 23). There were three complications which required operative intervention; one was a deep infection which required removal of the graft. The functional results gave a mean Musculoskeletal Tumor Society score of 85% (60% to 97%), a mean Toronto extremity salvage score of 86% (69% to 100%) and a mean Harris hip score of 92 (67 to 100).

We conclude that ECI grafting is a suitable form of treatment for localised and resectable pelvic Ewing’s sarcoma.