The aim of this study was to determine whether the rates of revision
for metal-on-metal (MoM) total hip arthroplasties (THAs) with Pinnacle
components varied according to the year of the initial operation,
and compare these with the rates of revision for other designs of
MoM THA. Data from the National Joint Registry for England and Wales included
36 mm MoM THAs with Pinnacle acetabular components which were undertaken
between 2003 and 2012 with follow-up for at least five years (n
= 10 776) and a control group of other MoM THAs (n = 13 817). The
effect of the year of the primary operation on all-cause rates of revision
was assessed using Cox regression and interrupted time-series analysis.Aims
Patients and Methods
We report on 397 consecutive revision total hip
replacements in 371 patients with a mean clinical and radiological follow-up
of 12.9 years (10 to 17.7). The mean age at surgery was 69 years
(37 to 93). A total of 28 patients (8%) underwent further revision,
including 16 (4%) femoral components. In all 223 patients (56%,
233 hips) died without further revision and 20 patients (5%, 20
hips) were lost to follow-up. Of the remaining patients, 209 (221
hips) were available for clinical assessment and 194 (205 hips)
for radiological review at mean follow-up of 12.9 years (10 to 17.7). The mean Harris Hip Score improved from 58.7 (11 to 92) points
to 80.7 (21 to 100) (p <
0.001) and the mean Merle d’Aubigné and
Postel hip scores at final follow-up were 4.9 (2 to 6), 4.5 (2 to
6) and 4.3 (2 to 6), respectively for pain, mobility and function.
Radiographs showed no lucencies around 186 (90.7%) femoral stems
with stable bony ingrowth seen in 199 stems (97%). The survival
of the S-ROM femoral stem at 15 years with revision for any reason as
the endpoint was 90.5% (95% confidence interval (CI) 85.7 to 93.8)
and with revision for aseptic loosening as the endpoint 99.3% (95%
CI 97.2 to 99.8). We have shown excellent long-term survivorship and good clinical
outcome of a cementless hydroxyapatite proximally-coated modular
femoral stem in revision hip surgery. Cite this article:
Intact abductors of the hip play a crucial role
in preventing limping and are known to be damaged through the direct lateral
approach. The extent of trauma to the abductors after revision total
hip replacement (THR) is unknown. The aim of this prospective study
was to compare the pre- and post-operative status of the gluteus
medius muscle after revision THR. We prospectively compared changes
in the muscle and limping in 30 patients who were awaiting aseptic
revision THR and 15 patients undergoing primary THR. The direct
lateral approach as described by Hardinge was used for all patients.
MRI scans of the gluteus medius and functional analyses were recorded
pre-operatively and six months post-operatively. The overall mean
fatty degeneration of the gluteus medius increased from 35.8% (1.1
to 98.8) pre-operatively to 41% (1.5 to 99.8) after multiple revision
THRs (p = 0.03). There was a similar pattern after primary THR,
but with considerably less muscle damage (p = 0.001), indicating
progressive muscle damage. Despite an increased incidence of a positive
Trendelenburg sign following revision surgery (p = 0.03) there was
no relationship between the cumulative fatty degeneration in the
gluteus medius and a positive Trendelenburg sign (p = 0.26). The
changes associated with other surgical approaches to the hip warrant
investigation. Cite this article:
This study aimed to determine the diagnostic performance of radiographic
criteria to detect aseptic acetabular loosening after revision total
hip arthroplasty (THA). Secondary aims were to determine the predictive
values of different thresholds of migration and to determine the
predictive values of radiolucency criteria. Acetabular component migration to re-revision was measured retrospectively
using Ein-Bild-Rontgen-Analyse (EBRA-Cup) and manual measurements
(Sutherland method) in two groups: Group A, 52 components (48 patients) found
not loose at re-revision and Group B, 42 components (36 patients)
found loose at re-revision between 1980 and 2015. The presence and
extent of radiolucent lines was also assessed.Aims
Patients and Methods
Our aim was to determine if the detection rate of infection of total hip replacements could be improved by examining the removed prostheses. Immediate transfer of prostheses to an anaerobic atmosphere, followed by mild ultrasonication to dislodge adherent bacteria, resulted in the culture of quantifiable numbers of bacteria, from 26 of the 120 implants examined. The same bacterial species were cultured by routine microbiological techniques from only five corresponding tissue samples. Tissue removed from 18 of the culture-positive implants was suitable for quantitative tissue pathology and inflammatory cells were present in all samples. Furthermore, inflammatory cells were present in 87% of tissue samples taken from patients whose implants were culture-negative. This suggests that these implants may have been infected by bacteria which were not isolated by the techniques of culture used. The increased detection of bacteria from prostheses by culture has improved postoperative antibiotic therapy and should reduce the need for further revision.
The newer techniques of cementing aim to improve interlock between cement and bone around a femoral stem by combining high pressure and reduced viscosity. This may produce increased embolisation of fat and marrow leading to hypotension, impaired pulmonary gas exchange and death. For this reason the use of high pressures has been questioned. We compared finger-packing with the use of a cement gun by measuring intramedullary pressures during the cementing of 31 total hip replacements and measuring physiological changes in 19 patients. We also measured pressure in more detail in a laboratory model. In the clinical series the higher pressures were produced by using a gun, but this caused less physiological disturbance than finger-packing. The laboratory studies showed more consistent results with the gun technique, but for both methods of cementing the highest pressures were generated during the insertion of the stem of the prosthesis.
We report a case of anterior compartment syndrome in the ipsilateral leg after a revision total hip arthroplasty. Possible causes include postchaemic swelling after occlusion of the vessels during prolonged surgery and vigorous repetitive stretching of the muscles of the anterior compartment from the intraoperative use of electrical calf stimulators. Epidural infusions for postoperative analgesia may mask symptoms, but when there is clinical suspicion, we recommend measurement of the compartment pressures and early fasciotomy.
Between 1965 and 1973 a total of 808 McKee-Farrar metal-on-metal cemented total hip arthroplasties were performed in the Norfolk and Norwich Hospital. Of these, 230 surviving arthroplasties have been reviewed at average follow-up of 13.9 years. There were good or excellent results in 49% of the arthroplasties as judged by the Harris hip score with 78% of these having little or no pain. A comprehensive radiographic analysis was undertaken and a survivorship study of 81% of the total number of prostheses is presented.
The management of joint replacement in lysosomal storage diseases has not been well reported. We present three patients with progressive degenerative changes of the hips who required bilateral total hip replacement in early childhood. The stature of the patients make it essential to have access to appropriately scaled prostheses. Consideration has to be given to associated disorders of the skeleton which must be carefully screened to ensure safety in providing appropriate anaesthesia as well as ensuring that there is no cardiac abnormality. In one patient, a periprosthetic fracture was sustained in one hip in the early post-operative course requiring internal fixation. The patient made a full recovery and all six hips were clinically and radiologically satisfactory at mid-term review.
The National Institute for Clinical Excellence (NICE) published the guidelines on the selection of prostheses for primary hip replacement in 2000. They supported the use of cemented hip prostheses to the exclusion of uncemented and hybrid implants. The information from the Trent (and Wales) Regional Arthroplasty Study has been examined to identify retrospectively the types of hip prostheses used between 1990 and 2005, and to assess the impact that the guidelines have had on orthopaedic practice. The results show that the publication of the NICE guidelines has had little impact on clinical practice, with the use of uncemented prostheses increasing from 6.7% (137) in 2001 to 19.2% (632) in 2005. The use of hybrid prostheses has more than doubled from 8.8% (181) to 22% (722) of all hips implanted in the same period. The recommendations made by NICE are not being followed, which calls into question their value.
Metal ions generated from joint replacements are a cause for concern. There is no consensus on the best surrogate measure of metal ion exposure. This study investigates whether serum and whole blood concentrations can be used interchangeably to report results of cobalt and chromium ion concentrations. Concentrations of serum and whole blood were analysed in 262 concurrent specimens using high resolution inductively-coupled plasma mass-spectrometry. The agreement was assessed with normalised scatterplots, mean difference and the Bland and Altman limits of agreement. The wide variability seen in the normalised scatterplots, in the Bland and Altman plots and the statistically significant mean differences between serum and whole blood concentrations suggest that they cannot be used interchangeably. A bias was demonstrated for both ions in the Bland-Altman plots. Regression analysis provided a possible conversion factor of 0.71 for cobalt and 0.48 for chromium. However, even when the correction factors were applied, the limits of agreement were greater than ±67% for cobalt and greater than ±85% for chromium, suggesting that serum and whole blood cannot be used interconvertibly. This suggests that serum metal concentrations are not useful as a surrogate measure of systemic metal ion exposure.
In a time of limited resources, the debate continues
over which types of hip prosthesis are clinically superior and more
cost-effective. Orthopaedic surgeons increasingly need robust economic
evidence to understand the full value of the operation, and to aid
decision making on the ‘package’ of procedures that are available
and to justify their practice beyond traditional clinical preference. In this paper we explore the current economic debate about the
merits of cemented and cementless total hip replacement, an issue
that continues to divide the orthopaedic community. Cite this article:
The piriformis muscle is an important landmark
in the surgical anatomy of the hip, particularly the posterior approach
for total hip replacement (THR). Standard orthopaedic teaching dictates
that the tendon must be cut in to allow adequate access to the superior
part of the acetabulum and the femoral medullary canal. However,
in our experience a routine THR can be performed through a posterior
approach without sacrificing this tendon. We dissected the proximal femora of 15 cadavers in order to clarify
the morphological anatomy of the piriformis tendon. We confirmed
that the tendon attaches on the crest of the greater trochanter,
in a position superior to the trochanteric fossa, away from the
entry point for broaching the intramedullary canal during THR. The
tendon attachment site encompassed the summit and medial aspect
of the greater trochanter as well as a variable attachment to the
fibrous capsule of the hip joint. In addition we dissected seven
cadavers resecting all posterior attachments except the piriformis
muscle and tendon in order to study their relations to the hip joint,
as the joint was flexed. At flexion of 90° the piriformis muscle
lay directly posterior to the hip joint. The piriform fossa is a term used by orthopaedic surgeons to
refer the trochanteric fossa and normally has no relation to the
attachment site of the piriformis tendon. In hip flexion the piriformis
lies directly behind the hip joint and might reasonably be considered
to contribute to the stability of the joint. We conclude that the anatomy of the piriformis muscle is often
inaccurately described in the current surgical literature and terms
are used and interchanged inappropriately. Cite this article:
The biological significance of cobalt-chromium wear particles from metal-on-metal hip replacements may be different to the effects of the constituent metal ions in solution. Bacteria may be able to discriminate between particulate and ionic forms of these metals because of a transmembrane nickel/cobalt-permease. It is not known whether wear particles are bacteriocidal. We compared the doubling time of coagulase negative staphylococcus, Doubling time halved in metal-on-metal (p = 0.003) and metal-on-polyethylene (p = 0.131) particulate debris compared with the control. Bacterial nickel/cobalt-transporters allow metal ions but not wear particles to cross bacterial membranes. This may be useful for testing the biological characteristics of different wear debris. This experiment also shows that metal-on-metal hip wear debris is not bacteriocidal.
We treated 50 consecutive patients with infected total hip arthroplasties according to a standard protocol. Previous surgery to eradicate the infection had been attempted in 13 patients and discharging sinuses were present in 20. Aspiration arthrography was routinely carried out before our interventions. The first stage was a meticulous removal of all foreign and potentially infected material. Samples were taken for culture and a thorough lavage carried out. Antibiotic-loaded beads were placed in the femoral shaft and an antibiotic-loaded cement ball in the acetabulum. At the second stage an uncemented arthroplasty was introduced. Bone allograft was used in 18 patients. The interval between procedures was usually three weeks, but this was extended if the wound was slow to heal or there was extensive bony destruction. Appropriate antibiotics were given for three months. At a mean follow-up of 5.8 years the rate of reinfection was 8% (4 patients). Two of these patients have had another, successful, two-stage revision. At this medium-term review, a satisfactory clinical and radiological outcome was obtained in all except two patients.
The complete removal of the cement mantle at revision arthroplasty can be extremely difficult. Some authors advise a ‘cement-within-cement’ revision technique in which a new layer of cement is applied to the old before insertion of the femoral component. We could find no long-term clinical data regarding the success of this procedure. In a simple biomechanical study, we examined the strength of the cement-to-cement interface in conditions likely to prevail in vivo. We found that the presence of a thin layer of blood and marrow debris at the interface weakened the cement-to-cement bond by 80% to 85%. These biomechanical findings and additional photomicrographic evidence do not support the practice of cement-within-cement revision arthroplasty.