Six patients with longitudinal stress fractures of the tibia and
Two cases of post-traumatic avascular necrosis of the head of the
Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA. We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation.Objectives
Methods
The term Volkmann’s triangle for the avulsed posterior edge of the tibia in fracture-dislocations of the ankle is incorrect. Volkmann did not publish any articles relating to the posterior edge of the tibia. Credit should go to Henry Earle, who was an outstanding British surgeon of the first half of 19th century. He described avulsion of the posterior edge of the tibia in 1828. In 1823 he also published a monograph entitled Practical observations in surgery in which he described a specially designed bed for the conservative treatment of proximal fractures of the
A patient with Paget's sarcoma of the
A Judet-type arthroplasty of the hip was performed. The patient died fourteen days after the operation. The upper end of the
Our aim was to evaluate the radiographic characteristics of patients
undergoing total hip arthroplasty (THA) for the potential of posterior
bony impingement using CT simulations. Virtual CT data from 112 patients who underwent THA were analysed.
There were 40 men and 72 women. Their mean age was 59.1 years (41
to 76). Associations between radiographic characteristics and posterior
bony impingement and the range of external rotation of the hip were
evaluated. In addition, we investigated the effects of pelvic tilt
and the neck/shaft angle and femoral offset on posterior bony impingement.Aims
Patients and Methods
This study reports on a secondary exploratory analysis of the early clinical outcomes of a randomised clinical trial comparing robotic arm-assisted unicompartmental knee arthroplasty (UKA) for medial compartment osteoarthritis of the knee with manual UKA performed using traditional surgical jigs. This follows reporting of the primary outcomes of implant accuracy and gait analysis that showed significant advantages in the robotic arm-assisted group. A total of 139 patients were recruited from a single centre. Patients were randomised to receive either a manual UKA implanted with the aid of traditional surgical jigs, or a UKA implanted with the aid of a tactile guided robotic arm-assisted system. Outcome measures included the American Knee Society Score (AKSS), Oxford Knee Score (OKS), Forgotten Joint Score, Hospital Anxiety Depression Scale, University of California at Los Angeles (UCLA) activity scale, Short Form-12, Pain Catastrophising Scale, somatic disease (Primary Care Evaluation of Mental Disorders Score), Pain visual analogue scale, analgesic use, patient satisfaction, complications relating to surgery, 90-day pain diaries and the requirement for revision surgery.Objectives
Methods
The aims of this study were to determine the proportion of patients
with outlier varus or valgus alignment in kinematically aligned
total knee arthroplasty (TKA), whether those with outlier varus
or valgus alignment have higher forces in the medial or lateral
compartments of the knee than those with in-range alignment and
whether measurements of the alignment of the limb, knee and components
predict compartment forces. The intra-operative forces in the medial and lateral compartments
were measured with an instrumented tibial insert in 67 patients
who underwent a kinematically aligned TKA during passive movement.
The mean of the forces at full extension, 45° and 90° of flexion
determined the force in the medial and lateral compartments. Measurements
of the alignment of the limb and the components included the hip-knee-ankle
(HKA) angle, proximal medial tibial angle (PMTA), and distal lateral
femoral angle (DLFA). Measurements of the alignment of the knee
and the components included the tibiofemoral angle (TFA), tibial
component angle (TCA) and femoral component angle (FCA). Alignment was
measured on post-operative, non-weight-bearing anteroposterior (AP)
scanograms and categorised as varus or valgus outlier or in-range
in relation to mechanically aligned criteria.Aims
Patients and Methods
The aim of this study was to identify the association between
asymmetrical skin creases of the thigh, buttock or inguinal region
and pathological developmental dysplasia of the hip (DDH). Between 1 January 1996 and 31 December 2016, all patients referred
to our unit from primary or secondary care with risk factors for
DDH were assessed in a “one stop” clinic. All had clinical and sonographic
assessment by the senior author (RWP) with the results being recorded
prospectively. The inclusion criteria for this study were babies and
children referred with asymmetrical skin creases. Those with a neurological
cause of DDH were excluded. The positive predictive value (PPV)
for pathological DDH was calculated.Aims
Patients and Methods
We discuss the role of primary knee arthroplasty in supracondylar and intercondylar fractures of the
A patient who presented with a malignant fibrous histiocytoma in the proximal
Microindentation has the potential to measure the stiffness of an individual patient’s bone. Bone stiffness plays a crucial role in the press-fit stability of orthopaedic implants. Arming surgeons with accurate bone stiffness information may reduce surgical complications including periprosthetic fractures. The question addressed with this systematic review is whether microindentation can accurately measure cortical bone stiffness. A systematic review of all English language articles using a keyword search was undertaken using Medline, Embase, PubMed, Scopus and Cochrane databases. Studies that only used nanoindentation, cancellous bone or animal tissue were excluded.Objectives
Methods
The case reports of four patients with breakage of the intramedullary nail of the
Taper junctions between modular hip arthroplasty femoral heads and stems fail by wear or corrosion which can be caused by relative motion at their interface. Increasing the assembly force can reduce relative motion and corrosion but may also damage surrounding tissues. The purpose of this study was to determine the effects of increasing the impaction energy and the stiffness of the impactor tool on the stability of the taper junction and on the forces transmitted through the patient’s surrounding tissues. A commercially available impaction tool was modified to assemble components in the laboratory using impactor tips with varying stiffness at different applied energy levels. Springs were mounted below the modular components to represent the patient. The pull-off force of the head from the stem was measured to assess stability, and the displacement of the springs was measured to assess the force transmitted to the patient’s tissues.Objectives
Methods
Templates are used in the preoperative planning of many orthopaedic procedures. The magnification of the bones on preoperative radiographs can vary despite using standardised radiological techniques. Templates will give misleading measurements unless this magnification is quantified. A coin may be used to calculate the magnification, with significant improvement in the accuracy of templating (p = 0.05). A group of patients undergoing uncemented arthroplasty of the hip was at high risk for intraoperative fracture of the
Mechanical and biomechanical testing of a new bone cement suggests that improved load transfer to the proximal
The aim of this study was to investigate the changes in femoral
trochlear morphology following surgical correction of recurrent
patellar dislocation associated with trochlear dysplasia in children. A total of 23 patients with a mean age of 9.6 years (7 to 11)
were included All had bilateral recurrent patellar dislocation associated
with femoral trochlear dysplasia. The knee with traumatic dislocation
at the time of presentation or that had dislocated most frequently
was treated with medial patellar retinacular plasty (Group S). The
contralateral knee served as a control and was treated conservatively
(Group C). All patients were treated between October 2008 and August
2013. The mean follow-up was 48.7 months (43 to 56). Axial CT scans
were undertaken in all patients to assess the trochlear morphological
characteristics on a particular axial image which was established
at the point with the greatest epicondylar width based on measurements
preoperatively and at the final follow-up.Aims
Patients and Methods
In patients over 60, both Paget's disease and metastatic carcinoma are not uncommon, but it is rare for both to occur in the same patient and in the same bone. One such patient is reported; she had primary carcinoma of the vulva which metastasised to a