Advertisement for orthosearch.org.uk
Results 1221 - 1240 of 3375
Results per page:
Bone & Joint Research
Vol. 9, Issue 6 | Pages 314 - 321
1 Jun 2020
Bliven E Sandriesser S Augat P von Rüden C Hackl S

Aims

Evaluate if treating an unstable femoral neck fracture with a locking plate and spring-loaded telescoping screw system would improve construct stability compared to gold standard treatment methods.

Methods

A 31B2 Pauwels’ type III osteotomy with additional posterior wedge was cut into 30 fresh-frozen femur cadavers implanted with either: three cannulated screws in an inverted triangle configuration (CS), a sliding hip screw and anti-rotation screw (SHS), or a locking plate system with spring-loaded telescoping screws (LP). Dynamic cyclic compressive testing representative of walking with increasing weight-bearing was applied until failure was observed. Loss of fracture reduction was recorded using a high-resolution optical motion tracking system.


Bone & Joint Research
Vol. 9, Issue 8 | Pages 468 - 476
1 Aug 2020
Parsons NR Costa ML Achten J Griffin XL

Aims

To assess the variation in pre-fracture quality of life (QoL) within the UK hip fracture population, and quantify the nature and strength of associations between QoL and other routinely collected patient characteristics and treatment choices.

Methods

The World Hip Trauma Evaluation (WHiTE) study, an observational cohort study of UK hip fracture patients, collects a range of routine data and a health-related QoL score (EuroQol five-dimension questionnaire (EQ-5D)). Pre-fracture QoL data are summarized and statistical models fitted to understand associations between QoL, patient characteristics, fracture types, and operations.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 434 - 441
1 Apr 2020
Hamilton DF Burnett R Patton JT MacPherson GJ Simpson AHRW Howie CR Gaston P

Aims

There are comparatively few randomized studies evaluating knee arthroplasty prostheses, and fewer still that report longer-term functional outcomes. The aim of this study was to evaluate mid-term outcomes of an existing implant trial cohort to document changing patient function over time following total knee arthroplasty using longitudinal analytical techniques and to determine whether implant design chosen at time of surgery influenced these outcomes.

Methods

A mid-term follow-up of the remaining 125 patients from a randomized cohort of total knee arthroplasty patients (initially comprising 212 recruited patients), comparing modern (Triathlon) and traditional (Kinemax) prostheses was undertaken. Functional outcomes were assessed with the Oxford Knee Score (OKS), knee range of movement, pain numerical rating scales, lower limb power output, timed functional assessment battery, and satisfaction survey. Data were linked to earlier assessment timepoints, and analyzed by repeated measures analysis of variance (ANOVA) mixed models, incorporating longitudinal change over all assessment timepoints.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1321 - 1329
1 Oct 2012
Sarmah SS Patel S Hossain FS Haddad FS

Radiological assessment of total and unicompartmental knee replacement remains an essential part of routine care and follow-up. Appreciation of the various measurements that can be identified radiologically is important. It is likely that routine plain radiographs will continue to be used, although there has been a trend towards using newer technologies such as CT, especially in a failing knee, where it provides more detailed information, albeit with a higher radiation exposure. The purpose of this paper is to outline the radiological parameters used to evaluate knee replacements, describe how these are measured or classified, and review the current literature to determine their efficacy where possible


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 805 - 806
1 Jul 2020
Haddad FS


Bone & Joint Open
Vol. 1, Issue 5 | Pages 152 - 159
22 May 2020
Oommen AT Chandy VJ Jeyaraj C Kandagaddala M Hariharan TD Arun Shankar A Poonnoose PM Korula RJ

Aims

Complex total hip arthroplasty (THA) with subtrochanteric shortening osteotomy is necessary in conditions other than developmental dysplasia of the hip (DDH) and septic arthritis sequelae with significant proximal femur migration. Our aim was to evaluate the hip centre restoration with THAs in these hips.

Methods

In all, 27 THAs in 25 patients requiring THA with femoral shortening between 2012 and 2019 were assessed. Bilateral shortening was required in two patients. Subtrochanteric shortening was required in 14 out of 27 hips (51.9%) with aetiology other than DDH or septic arthritis. Vertical centre of rotation (VCOR), horizontal centre of rotation, offset, and functional outcome was calculated. The mean followup was 24.4 months (5 to 92 months).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1487 - 1493
1 Nov 2012
Wensaas A Gunderson RB Svenningsen S Terjesen T

Deformity after slipped upper femoral epiphysis (SUFE) can cause cam-type femoroacetabular impingement (FAI) and subsequent osteoarthritis (OA). However, there is little information regarding the radiological assessment and clinical consequences at long-term follow-up. We reviewed 36 patients (43 hips) previously treated by in situ fixation for SUFE with a mean follow-up of 37 years (21 to 50). Three observers measured the femoral head ratio (FHR), lateral femoral head ratio (LFHR), α-angle on anteroposterior (AP) and frog-leg lateral views, and anterior femoral head–neck offset ratio (OSR). A Harris hip score < 85 and/or radiologically diagnosed osteoarthritis (OA) was classified as a poor outcome. Patients with SUFE had significantly higher FHR, LFHR and α-angles and lower OSR than a control group of 22 subjects (35 hips) with radiologically normal hips. The interobserver agreement was less, with wider limits of agreement (LOA), in hips with previous SUFE than the control group. At long-term follow-up abnormal α-angles correlated with poor outcome, whereas FHR, LFHR and OSR did not. We conclude that persistent deformity with radiological cam FAI after SUFE is associated with poorer clinical and radiological long-term outcome. Although the radiological measurements had quite wide limits of agreement, they are useful for the diagnosis of post-slip deformities in clinical practice


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1101 - 1105
1 Aug 2013
Haug LC Glodny B Deml C Lutz M Attal R

Penetration of the dorsal screw when treating distal radius fractures with volar locking plates is an avoidable complication that causes lesions of the extensor tendon in between 2% and 6% of patients. We examined axial fluoroscopic views of the distal end of the radius to observe small amounts of dorsal screw penetration, and determined the ideal angle of inclination of the x-ray beam to the forearm when making this radiological view. Six volar locking plates were inserted at the wrists of cadavers. The actual screw length was measured under direct vision through a dorsal approach to the distal radius. Axial radiographs were performed for different angles of inclination of the forearm at the elbow. Comparing axial radiological measurements and real screw length, a statistically significant correlation could be demonstrated at an angle of inclination between 5° and 20°. The ideal angle of inclination required to minimise the risk of implanting over-long screws in a dorsal horizon radiological view is 15°. Cite this article: Bone Joint J 2013;95-B:1101–5


Bone & Joint Open
Vol. 1, Issue 5 | Pages 103 - 114
13 May 2020
James HK Gregory RJH Tennent D Pattison GTR Fisher JD Griffin DR

Aims

The primary aim of the survey was to map the current provision of simulation training within UK and Republic of Ireland (RoI) trauma and orthopaedic (T&O) specialist training programmes to inform future design of a simulation based-curriculum. The secondary aims were to characterize; the types of simulation offered to trainees by stage of training, the sources of funding for simulation, the barriers to providing simulation in training, and to measure current research activity assessing the educational impact of simulation.

Methods

The development of the survey was a collaborative effort between the authors and the British Orthopaedic Association Simulation Group. The survey items were embedded in the Performance and Opportunity Dashboard, which annually audits quality in training across several domains on behalf of the Speciality Advisory Committee (SAC). The survey was sent via email to the 30 training programme directors in March 2019. Data were retrieved and analyzed at the Warwick Clinical Trials Unit, UK.


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 967 - 980
1 Aug 2020
Chou TA Ma H Wang J Tsai S Chen C Wu P Chen W

Aims

The aims of this study were to validate the outcome of total elbow arthroplasty (TEA) in patients with rheumatoid arthritis (RA), and to identify factors that affect the outcome.

Methods

We searched PubMed, MEDLINE, Cochrane Reviews, and Embase from between January 2003 and March 2019. The primary aim was to determine the implant failure rate, the mode of failure, and risk factors predisposing to failure. A secondary aim was to identify the overall complication rate, associated risk factors, and clinical performance. A meta-regression analysis was completed to identify the association between each parameter with the outcome.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 279 - 285
1 Feb 2013
Engesæter IØ Laborie LB Lehmann TG Fevang JM Lie SA Engesæter LB Rosendahl K

In Norway total joint replacement after hip dysplasia is reported more commonly than in neighbouring countries, implying a higher prevalence of the condition. We report on the prevalence of radiological features associated with hip dysplasia in a population of 2081 19-year-old Norwegians. The radiological measurements used to define hip dysplasia were Wiberg’s centre-edge (CE) angle at thresholds of < 20° and < 25°, femoral head extrusion index <  75%, Sharp’s angle > 45°, an acetabular depth to width ratio < 250 and the sourcil shape assessed subjectively. The whole cohort underwent clinical examination of their range of hip movement, body mass index (BMI), and Beighton hypermobility score, and were asked to complete the EuroQol (EQ-5D) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). The prevalence of hip dysplasia in the cohort varied from 1.7% to 20% depending on the radiological marker used. A Wiberg’s CE angle <  20° was seen in 3.3% of the cohort: 4.3% in women and 2.4% in men. We found no association between subjects with multiple radiological signs indicative of dysplasia and BMI, Beighton score, EQ-5D or WOMAC. Although there appears to be a high prevalence of hip dysplasia among 19-year-old Norwegians, this is dependent on the radiological parameters applied. Cite this article: Bone Joint J 2013;95-B:279–85


Bone & Joint Open
Vol. 1, Issue 7 | Pages 398 - 404
15 Jul 2020
Roebke AJ Via GG Everhart JS Munsch MA Goyal KS Glassman AH Li M

Aims

Currently, there is no single, comprehensive national guideline for analgesic strategies for total joint replacement. We compared inpatient and outpatient opioid requirements following total hip arthroplasty (THA) versus total knee arthroplasty (TKA) in order to determine risk factors for increased inpatient and outpatient opioid requirements following total hip or knee arthroplasty.

Methods

Outcomes after 92 primary total knee (n = 49) and hip (n = 43) arthroplasties were analyzed. Patients with repeat surgery within 90 days were excluded. Opioid use was recorded while inpatient and 90 days postoperatively. Outcomes included total opioid use, refills, use beyond 90 days, and unplanned clinical encounters for uncontrolled pain. Multivariate modelling determined the effect of surgery, regional nerve block (RNB) or neuraxial anesthesia (NA), and non-opioid medications after adjusting for demographics, ength of stay, and baseline opioid use.


Bone & Joint Open
Vol. 1, Issue 5 | Pages 131 - 136
15 May 2020
Key T Mathai NJ Venkatesan AS Farnell D Mohanty K

Aims

The adequate provision of personal protective equipment (PPE) for healthcare workers has come under considerable scrutiny during the COVID-19 pandemic. This study aimed to evaluate staff awareness of PPE guidance, perceptions of PPE measures, and concerns regarding PPE use while caring for COVID-19 patients. In addition, responses of doctors, nurses, and other healthcare professionals (OHCPs) were compared.

Methods

The inclusion criteria were all staff working in clinical areas of the hospital. Staff were invited to take part using a link to an online questionnaire advertised by email, posters displayed in clinical areas, and social media. Questions grouped into the three key themes - staff awareness, perceptions, and concerns - were answered using a five-point Likert scale. The Kruskal-Wallis test was used to compare results across all three groups of staff.


Bone & Joint Open
Vol. 1, Issue 7 | Pages 384 - 391
10 Jul 2020
McCahill JL Stebbins J Harlaar J Prescott R Theologis T Lavy C

Aims

To assess if older symptomatic children with club foot deformity differ in perceived disability and foot function during gait, depending on initial treatment with Ponseti or surgery, compared to a control group. Second aim was to investigate correlations between foot function during gait and perceived disability in this population.

Methods

In all, 73 children with idiopathic club foot were included: 31 children treated with the Ponseti method (mean age 8.3 years; 24 male; 20 bilaterally affected, 13 left and 18 right sides analyzed), and 42 treated with primary surgical correction (mean age 11.6 years; 28 male; 23 bilaterally affected, 18 left and 24 right sides analyzed). Foot function data was collected during walking gait and included Oxford Foot Model kinematics (Foot Profile Score and the range of movement and average position of each part of the foot) and plantar pressure (peak pressure in five areas of the foot). Oxford Ankle Foot Questionnaire, Disease Specific Index for club foot, Paediatric Quality of Life Inventory 4.0 were also collected. The gait data were compared between the two club foot groups and compared to control data. The gait data were also correlated with the data extracted from the questionnaires.


Bone & Joint Research
Vol. 9, Issue 7 | Pages 333 - 340
1 Jul 2020
Mumith A Coathup M Edwards TC Gikas P Aston W Blunn G

Aims

Limb salvage in bone tumour patients replaces the bone with massive segmental prostheses where achieving bone integration at the shoulder of the implant through extracortical bone growth has been shown to prevent loosening. This study investigates the effect of multidrug chemotherapy on extracortical bone growth and early radiological signs of aseptic loosening in patients with massive distal femoral prostheses.

Methods

A retrospective radiological analysis was performed on adult patients with distal femoral arthroplasties. In all, 16 patients were included in the chemotherapy group with 18 patients in the non-chemotherapy control group. Annual radiographs were analyzed for three years postoperatively. Dimensions of the bony pedicle, osseointegration of the hydroxyapatite (HA) collar surface, bone resorption at the implant shoulder, and radiolucent line (RLL) formation around the cemented component were analyzed.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 861 - 867
1 Jul 2020
Hiranaka T Yoshikawa R Yoshida K Michishita K Nishimura T Nitta S Takashiba K Murray D

Aims

Cementless unicompartmental knee arthroplasty (UKA) has advantages over cemented UKA, including improved fixation, but has a higher risk of tibial plateau fracture, particularly in Japanese patients. The aim of this multicentre study was to determine when cementless tibial components could safely be used in Japanese patients based on the size and shape of the tibia.

Methods

The study involved 212 cementless Oxford UKAs which were undertaken in 174 patients in six hospitals. The medial eminence line (MEL), which is a line parallel to the tibial axis passing through the tip of medial intercondylar eminence, was drawn on preoperative radiographs. Knees were classified as having a very overhanging medial tibial condyle if this line passed medial to the medial tibial cortex. They were also classified as very small if a size A/AA tibial component was used.


Bone & Joint Research
Vol. 9, Issue 7 | Pages 394 - 401
1 Jul 2020
Blirup-Plum SA Bjarnsholt T Jensen HE Kragh KN Aalbæk B Gottlieb H Bue M Jensen LK

Aims

CERAMENT|G is an absorbable gentamicin-loaded biocomposite used as an on-site vehicle of antimicrobials for the treatment of chronic osteomyelitis. The purpose of the present study was to investigate the sole effect of CERAMENT|G, i.e. without additional systemic antimicrobial therapy, in relation to a limited or extensive debridement of osteomyelitis lesions in a porcine model.

Methods

Osteomyelitis was induced in nine pigs by inoculation of 104 colony-forming units (CFUs) of Staphylococcus aureus into a drill hole in the right tibia. After one week, the pigs were allocated into three groups. Group A (n = 3) received no treatment during the study period (19 days). Groups B (n = 3) and C (n = 3) received limited or extensive debridement seven days postinoculation, respectively, followed by injection of CERAMENT|G into the bone voids. The pigs were euthanized ten (Group C) and 12 (Group B) days after the intervention.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 388 - 393
1 Mar 2020
French SR Kaila R Munir S Wood DG

Aims

To validate the Sydney Hamstring Origin Rupture Evaluation (SHORE), a hamstring-specific clinical assessment tool to evaluate patient outcomes following surgical treatment.

Methods

A prospective study of 70 unilateral hamstring surgical repairs, with a mean age of 47.3 years (15 to 73). Patients completed the SHORE preoperatively and at six months post-surgery, and then completed both the SHORE and Perth Hamstring Assessment Tool (PHAT) at three years post-surgery. The SHORE questionnaire was validated through the evaluation of its psychometric properties, including; internal consistency, reproducibility, reliability, sensitivity to change, and ceiling effect. Construct validity was assessed using Pearson’s correlation analysis to examine the strength of association between the SHORE and the PHAT.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 904 - 911
1 Jul 2020
Sigmund IK Dudareva M Watts D Morgenstern M Athanasou NA McNally MA

Aims

The aim of this study was to evaluate the diagnostic value of preoperative serum CRP, white blood cell count (WBC), percentage of neutrophils (%N), and neutrophil to lymphocyte ratio (NLR) when using the fracture-related infection (FRI) consensus definition.

Methods

A cohort of 106 patients having surgery for suspected septic nonunion after failed fracture fixation were studied. Blood samples were collected preoperatively, and the concentration of serum CRP, WBC, and differential cell count were analyzed. The areas under the curve (AUCs) of diagnostic tests were compared using the z-test. Regression trees were constructed and internally cross-validated to derive a simple diagnostic decision tree.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 452 - 458
1 Apr 2013
Lehmann TG Engesæter IØ Laborie LB Lie SA Rosendahl K Engesæter LB

The reported prevalence of an asymptomatic slip of the contralateral hip in patients operated on for unilateral slipped capital femoral epiphysis (SCFE) is as high as 40%. Based on a population-based cohort of 2072 healthy adolescents (58% women) we report on radiological and clinical findings suggestive of a possible previous SCFE. Common threshold values for Southwick’s lateral head–shaft angle (≥ 13°) and Murray’s tilt index (≥ 1.35) were used. New reference intervals for these measurements at skeletal maturity are also presented. At follow-up the mean age of the patients was 18.6 years (17.2 to 20.1). All answered two questionnaires, had a clinical examination and two hip radiographs. There was an association between a high head–shaft angle and clinical findings associated with SCFE, such as reduced internal rotation and increased external rotation. Also, 6.6% of the cohort had Southwick’s lateral head–shaft angle ≥ 13°, suggestive of a possible slip. Murray’s tilt index ≥ 1.35 was demonstrated in 13.1% of the cohort, predominantly in men, in whom this finding was associated with other radiological findings such as pistol-grip deformity or focal prominence of the femoral neck, but no clinical findings suggestive of SCFE. This study indicates that 6.6% of young adults have radiological findings consistent with a prior SCFE, which seems to be more common than previously reported. Cite this article: Bone Joint J 2013;95-B:452–8