Advertisement for orthosearch.org.uk
Results 1201 - 1220 of 2593
Results per page:
Bone & Joint 360
Vol. 8, Issue 2 | Pages 33 - 35
1 Apr 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 831 - 834
1 Sep 1996
Koot VCM Kesselaer SMMJ Clevers GJ de Hooge P Weits T van der Werken C

We studied the reliability of the Singh classification of trabecular bone structure in the proximal femur as a measure of osteoporosis, using kappa statistics. Radiographs of fractures of the femoral neck or trochanteric region in 80 consecutive patients were assessed by six observers. The interobserver variation was large; only three of 72 radiographs were given the same classification by all six observers and the kappa values ranged from 0.15 to 0.54. The intraobserver variation showed substantial strength of agreement; kappa values ranged from 0.63 to 0.88. In 77 patients dual-energy X-ray absorptiometry was used to measure bone mineral density. The results were compared with those of the Singh classification: we found no correlation


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 787 - 792
1 Sep 1996
Wachtl SW Sennwald GR

We treated 43 patients (38 women and 5 men) with osteoarthritis of the basal joint of the thumb by non-cemented arthroplasty of the first carpometacarpal joint as described by Ledoux. The probability of a patient avoiding revision for 12 months was 62% and for 16 months 59%. The indications for revision were aseptic loosening in 83% and luxation in 17%. The surviving prostheses were reviewed clinically and radiologically at a mean follow-up of 25.3 months. Pain on loading, movement or at rest was seen in 75% of the patients. There was significant reduction in the range of movement of the trapeziometacarpal joint and of wrist strength. Radiological assessment showed significant subsidence of the stem in the first metacarpal and migration of the cup, with the stem loose in 15% and the cup in 46%. We no longer recommend this method of joint replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 137 - 140
1 Jan 1990
Lidor C Dekel S Meyer M Blaugrund E Hallel T Edelstein S

In vitamin D-fed chicks 1,25-dihydroxyvitamin D3 and 24,25-dihydroxyvitamin D3 were implanted into experimentally-produced fractures of the mid-tibia. The mechanical and biochemical properties of the tibia were evaluated for two weeks, including torsion tests, measurement of alkaline phosphatase activity, 45Ca incorporation, and Ca2+ content. Both dihydroxylated metabolites of vitamin D3 had a direct effect on endochondral bone formation. 24,25(OH)2D3 strengthened the callus, and raised alkaline phosphate activity in the first seven days after fracture. 1,25(OH)2D3 decreased the strength of the callus concomitant with a reduction in 45Ca incorporation. It is suggested that local application of 24,25(OH)2D3 into fractures may accelerate healing and prevent non-union


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 665 - 669
1 Jul 1998
McQueen MM

A randomised, prospective study was carried out on 60 patients with unstable fractures of the distal radius to compare bridging with non-bridging external fixation using pins placed in the distal fragment of the radius. The radiological results showed significant improvement in the non-bridging group at all stages of review. In particular, normal volar tilt and carpal alignment were regained and maintained. The functional results at six weeks, three months, six months and one year showed statistically better grip strength and flexion in the non-bridging group at all stages of review. Other ranges of movement showed an early advantage in the non-bridging group. Non-bridging external fixation is the treatment of choice for unstable fractures of the distal radius which have sufficient space for the placement of pins in the distal fragment


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 625 - 629
1 Aug 1985
Adams M Hutton W

A series of experiments showing how posture affects the lumbar spine is reviewed. Postures which flatten (that is, flex) the lumbar spine are compared with those that preserve the lumbar lordosis. Our review shows that flexed postures have several advantages: flexion improves the transport of metabolites in the intervertebral discs, reduces the stresses on the apophyseal joints and on the posterior half of the annulus fibrosus, and gives the spine a high compressive strength. Flexion also has disadvantages: it increases the stress on the anterior annulus and increases the hydrostatic pressure in the nucleus pulposus at low load levels. The disadvantages are not of much significance and we conclude that it is mechanically and nutritionally advantageous to flatten the lumbar spine when sitting and when lifting heavy weights


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 1 | Pages 123 - 131
1 Feb 1954
Enticknap JB

1. A case is described of the marble bone disease of Albers-Schönberg in a woman of forty-one who died from subarachnoid haemorrhage. Several congenital abnormalities were present. 2. No significant abnormality of the chemical composition of the bones was discovered. 3. The long bones were more resilient, stronger, softer and of higher specific gravity than normal and the abnormal compact bone of the skull was less resilient, weaker, harder and of about the same density as normal bones. 4. The simple investigation of determining the breaking strength of cortical bone yielded results similar to the more complex investigations and if applied to a larger series of cases could provide sound data on which to base speculations about this condition


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 914 - 917
1 Nov 1993
Janes G Collopy D Price R Sikorski J

We used dual-energy X-ray absorptiometry (DEXA) to measure the bone mineral content (BMC) of both tibiae in 13 patients who had been treated for a tibial fracture by rigid plate fixation. Within two weeks of plate removal the BMC was significantly greater in the bone that had been under the plate than at the same site in the control tibia. An unplated area of bone near the ankle showed a significant decrease in BMC at the time of plate removal with subsequent return to the level of the control tibia during the ensuing 18 months. We conclude that osteoinductive influences outweigh the potential causes of osteopenia, such as stress shielding and disuse, and that, contrary to expectation, demineralisation is not a factor in the diminished strength of the tibia after plating for fracture


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 48 - 54
1 Jul 2019
Kahlenberg CA Lyman S Joseph AD Chiu Y Padgett DE

Aims

The outcomes of total knee arthroplasty (TKA) depend on many factors. The impact of implant design on patient-reported outcomes is unknown. Our goal was to evaluate the patient-reported outcomes and satisfaction after primary TKA in patients with osteoarthritis undergoing primary TKA using five different brands of posterior-stabilized implant.

Patients and Methods

Using our institutional registry, we identified 4135 patients who underwent TKA using one of the five most common brands of implant. These included Biomet Vanguard (Zimmer Biomet, Warsaw, Indiana) in 211 patients, DePuy/Johnson & Johnson Sigma (DePuy Synthes, Raynham, Massachusetts) in 222, Exactech Optetrak Logic (Exactech, Gainesville, Florida) in 1508, Smith & Nephew Genesis II (Smith & Nephew, London, United Kingdom) in 1415, and Zimmer NexGen (Zimmer Biomet) in 779 patients. Patients were evaluated preoperatively using the Knee Injury and Osteoarthritis Outcome Score (KOOS), Lower Extremity Activity Scale (LEAS), and 12-Item Short-Form Health Survey questionnaire (SF-12). Demographics including age, body mass index, Charlson Comorbidity Index, American Society of Anethesiologists status, sex, and smoking status were collected. Postoperatively, two-year KOOS, LEAS, SF-12, and satisfaction scores were compared between groups.


Bone & Joint Research
Vol. 8, Issue 7 | Pages 349 - 356
1 Jul 2019
Starlinger J Kaiser G Thomas A Sarahrudi K

Objectives

The osteoprotegerin (OPG) and receptor activator of nuclear factor kappa-B ligand (RANKL) balance is of the utmost importance in fracture healing. The aim of this study was therefore to investigate the impact of nonosteogenic factors on OPG and RANKL levels.

Methods

Serum obtained from 51 patients with long bone fractures was collected over 48 weeks. The OPG and serum sRANKL (soluble RANKL) concentrations were measured using enzyme-linked immunosorbent assay (ELISA). Smoking habit, diabetes, and alcohol consumption were recorded.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1199 - 1204
1 Nov 2002
Race A Miller MA Ayers DC Cleary RJ Mann KA

We have compared the interface morphology at the stem-cement interface of standard Charnley stems with a satin finish (Ra = 0.75 μm) with identical stems which had been grit-blasted over their proximal third (Ra = 5.3 μm) to promote a proximal bond. The stems were cemented into cadaver femora using conventional contemporary cementing techniques. After transverse sectioning, we determined the percentage of the perimeter of the stem which had a gap at the interface. There were substantial gaps (mean 31.4 ± 17.1%) at the stem-cement interface in the grit-blasted region. This fraction was significantly (paired t-test, p = 0.0054) higher than that found around the contralateral satin-finished stems (mean 7.7 ± 11.7%). Although studies of isolated metal-cement interfaces have shown that the bond strength can increase with surface roughness it cannot be assumed that this effect will be observed under clinical conditions


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 2 | Pages 412 - 423
1 May 1962
Stevens J Ray RD

1. Some physical properties of living and dead bone have been studied in rats; most of these are interrelated and ultimately depend upon the composition of the tissue. 2. Dead bone, remaining within the body, does not take up measurable amounts of mineral from the tissue fluid but retains its original physical properties of radiographic density, specific gravity, strength and composition. 3. The altered radiographic density of avascular bone seen in clinical practice is almost certainly relative unless there has been concomitant appositional new bone formation. 4. Some other explanation must be sought for the finding that dead bone takes up significant amounts of bone-seeking isotopes in radioactive tracer studies


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 1 | Pages 82 - 87
1 Jan 1994
Jonsson H Elmqvist L Karrholm J Tegner Y

We report a review of 54 patients with chronic anterior cruciate ligament rupture treated by patellar-quadriceps tendon graft augmented with polypropylene braid (Kennedy-LAD). The femoral placement of the graft was randomised to either a modified over-the-top (OTT) or a tunnel position obtained by an isometric drill guide (ISO). At the two-year follow-up both procedures had resulted in improvement of subjective knee function and activity level. Stereoradiographic measurements showed reduction of anteroposterior laxity to near normal in about one-third of the patients, but muscle strength and objective functional performance showed little or no changes. The OTT group had better subjective knee function. We were unable to confirm the theoretical advantages of the use of the drill guide, partly because it provided a tibial tunnel which was too anterior


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 760 - 767
1 Jul 2019
Galea VP Rojanasopondist P Laursen M Muratoglu OK Malchau H Bragdon C

Aims

Vitamin E-diffused, highly crosslinked polyethylene (VEPE) and porous titanium-coated (PTC) shells were introduced in total hip arthroplasty (THA) to reduce the risk of aseptic loosening. The purpose of this study was: 1) to compare the wear properties of VEPE to moderately crosslinked polyethylene; 2) to assess the stability of PTC shells; and 3) to report their clinical outcomes at seven years.

Patients and Methods

A total of 89 patients were enrolled into a prospective study. All patients received a PTC shell and were randomized to receive a VEPE liner (n = 44) or a moderately crosslinked polyethylene (ModXLPE) liner (n = 45). Radiostereometric analysis (RSA) was used to measure polyethylene wear and component migration. Differences in wear were assessed while adjusting for body mass index, activity level, acetabular inclination, anteversion, and head size. Plain radiographs were assessed for radiolucency and patient-reported outcome measures (PROMs) were administered at each follow-up.


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 478 - 483
1 Apr 2019
Borg T Hernefalk B Hailer NP

Aims

Displaced, comminuted acetabular fractures in the elderly are increasingly common, but there is no consensus on whether they should be treated non-surgically, surgically with open reduction and internal fixation (ORIF), or with acute total hip arthroplasty (THA). A combination of ORIF and acute THA, an approach called ’combined hip procedure’ (CHP), has been advocated and our aim was to compare the outcome after CHP or ORIF alone.

Patients and Methods

A total of 27 patients with similar acetabular fractures (severe acetabular impaction with or without concomitant femoral head injury) with a mean age of 72.2 years (50 to 89) were prospectively followed for a minimum of two years. In all, 14 were treated with ORIF alone and 13 were treated with a CHP. Hip joint and patient survival were estimated. Operating times, blood loss, radiological outcomes, and patient-reported outcomes were assessed.


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 396 - 402
1 Apr 2019
Ji B Wahafu T Li G Zhang X Wang Y Momin M Cao L

Aims

Single-stage revision is not widely pursued due to restrictive inclusion criteria. In this study, we evaluated the results of single-stage revision of chronically infected total hip arthroplasty (THA) using broad inclusion criteria and cementless implants.

Patients and Methods

Between 2010 and 2016, 126 patients underwent routine single-stage revision with cementless reconstruction with powdered vancomycin or imipenem poured into the medullary cavity and re-implantation of cementless components. For patients with a culture-negative hip, fungal infections, and multidrug-resistant organisms, a direct intra-articular infusion of pathogen-sensitive antibiotics was performed postoperatively. Recurrence of infection and clinical outcomes were evaluated. Three patients died and 12 patients (none with known recurrent infection) were lost to follow-up. There were 111 remaining patients (60 male, 51 female) with a mean age of 58.7 (sd 12.7; 20 to 79).


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 409 - 411
1 May 1991
Vangsness C Jobe F

We reviewed 35 of 38 consecutive patients who had operative treatment for medial epicondylitis of the elbow after the failure of conservative management. Their mean age was 43 years and mean follow-up was 85 months. At operation residual tears with incomplete healing were consistently found in the flexor origin at the medial epicondyle and microscopy showed reactive fibrous connective tissue with varying degrees of inflammation. The mean subjective estimate of elbow function was improved from 38% to 98% of normal, while isokinetic and grip strength testing in 16 patients showed no significant difference from the unoperated elbow. Results were excellent in 25 cases, good in nine and fair in one; 86% of the patients had no limitation in the use of the elbow


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 797 - 800
1 Sep 1990
Clark D Crofts C Saleh M

The rigidity of a sliding compression screw and three cannulated lag screws in the treatment of subcapital fractures was compared in five pairs of female cadaver femora. There were no significant differences between the compressive strength, bone density, cortical thickness or Singh index of the bones in each pair. A subcapital fracture was standardised using a perpendicular saw cut across the femoral neck. A uniaxial 'load test system' with force and length measurement facilities was used to mimic cyclical stressing applied in vivo at a frequency of 0.5 Hz from 0 to 3 times body-weight. There was no significant difference between the fixation afforded by the sliding compression screw and three lag screws. Bone quality was the single most important factor in the stability of the bone implant unit


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 383 - 387
1 May 1989
Breek J Tan A van Thiel T Daantje C

We report the use of a free tendon graft in 70 patients to repair lesions of the capsuloligamentous complex of the metacarpophalangeal joint of the thumb. Of these 37 had a lesion of the ulnar collateral ligament, 18 of the radial collateral and 11 of the volar plate. Four patients had combined lesions. We outline our techniques and review 51 of the patients. Of those 47 (92%) were satisfied, and all but one had regained full stability. Pinch grip strength was normal in 48. About one-third of the patients had some loss of flexion/extension; this was seldom noticed by the patients and caused no significant disability. Free tendon graft reconstruction is indicated for severe fresh lesions, for old lesions with chronic disability and for lesions which have not responded to conservative management


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 126 - 130
1 Jan 2000
Kurth AHA Kim S Sedlmeyer I Hovy L Bauss F

Cancer-induced bone diseases are often associated with increased bone resorption and pathological fractures. In recent years, osteoprotective agents such as bisphosphonates have been studied extensively and have been shown to inhibit cancer-related bone resorption in experimental and clinical studies. The third-generation bisphosphonate, ibandronate (BM 21.0955), is a potent compound for controlling tumour osteolysis and hypercalcaemia in rats bearing Walker 256 carcinosarcoma. We have studied the effect of ibandronate given as an interventional treatment on bone strength and bone loss after the onset of tumour growth in bone. Our results suggest that it is capable of preserving bone quality in rats bearing Walker 256 carcinosarcoma cells. Since other bisphosphonates have produced comparable results in man after their success in the Walker 256 animal models our findings suggest that ibandronate may be a powerful treatment for maintaining skeletal integrity in patients with metastatic bone disease