Aims. Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. Methods. NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact
Aims. The aim of this study was to investigate the outcomes of arthroscopic decompression of calcific tendinitis performed without repairing the
Aims. The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis. Methods. From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration. Results. Five shoulders underwent revision surgery (3.5%); three for
Aims. Despite recent advances in arthroscopic rotator cuff repair, re-tear rates remain high. New methods to improve healing rates following
The April 2024 Shoulder & Elbow Roundup. 360. looks at: Acute rehabilitation following traumatic anterior shoulder dislocation (ARTISAN): pragmatic, multicentre, randomized controlled trial; Prevalence and predisposing factors of neuropathic pain in patients with
Objectives. The most prevalent disorders of the shoulder are related to the
muscles of
Shoulder injury related to vaccine administration (SIRVA) is a prolonged episode of shoulder dysfunction that commences within 24 to 48 hours of a vaccination. Symptoms include a combination of shoulder pain, stiffness, and weakness. There has been a recent rapid increase in reported cases of SIRVA within the literature, particularly in adults, and is likely related to the mass vaccination programmes associated with COVID-19 and influenza. The pathophysiology is not certain, but placement of the vaccination in the subdeltoid bursa or other pericapsular tissue has been suggested to result in an inflammatory capsular process. It has been hypothesized that this is associated with a vaccine injection site that is “too high” and predisposes to the development of SIRVA. Nerve conduction studies are routinely normal, but further imaging can reveal deep-deltoid collections,
Aims. Advances in arthroscopic techniques for
Aims. The appropriate management for patients with a degenerative tear
of the
Aims. The aim of this study is to evaluate the change in incidence rate of shoulder arthroplasty, indications, and surgeon volume trends associated with these procedures between January 2003 and April 2021 in the province of Nova Scotia, Canada. Methods. A total of 1,545 patients between 2005 and 2021 were analyzed. Patients operated on between 2003 and 2004 were excluded due to a lack of electronic records. Overall, 84.1% of the surgeries (n = 1,299) were performed by two fellowship-trained upper limb surgeons, with the remainder performed by one of the 14 orthopaedic surgeons working in the province. Results. Total shoulder arthroplasty (TSA) was the most frequent procedure (32.17%; n = 497), followed by stemmed hemiarthroplasty (SHA) (27.7%; n = 428). The most frequent indication for primary shoulder arthroplasty was degenerative osteoarthritis (58.1%; n = 882), followed by acute proximal humerus fracture in 15.11% (n = 245), and
Objectives. Triamcinolone acetonide (TA) is widely used for the treatment of
Reversed shoulder prostheses are increasingly being used for the treatment of glenohumeral arthropathy associated with a deficient
We have compared the outcome of hemiarthroplasty of the shoulder in three distinct diagnostic groups, using survival analysis as used by the United Kingdom national joint registers, patient-reported outcome measures (PROMs) as recommended by Darzi in the 2008 NHS review, and transition and satisfaction questions. A total of 72 hemiarthroplasties, 19 for primary osteoarthritis (OA) with an intact
Aims. The aim of this study was to analyze the results of reverse shoulder
arthroplasty (RSA) in patients with type 1 sequelae of a fracture
of the proximal humerus in association with
The April 2015 Shoulder &
Elbow Roundup. 360 . looks at: Distal clavicular resection not indicated in cuff repair?; Platelet-rich plasma in
There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a follow-up of at least ten years, 12 patients had died with the prosthesis intact and two had emigrated, leaving 25 available for clinical review. Of these, 13 had rheumatoid arthritis and 12 osteoarthritis. One refused radiological review leaving 24 with fresh radiographs. Survivorship at ten years was 100% for the humeral component and 92% for the glenoid component. The incidence of lucent lines was low. No humeral component was thought to be at risk and only two glenoid components. The osteoarthritic group gained a mean 65° in forward flexion and their Constant score improved by a mean 41.4 points (13 to 55). The rheumatoid group gained a mean of 24° in flexion and their Constant score improved by 29.4 points. This difference may have been due to failure of the
Aims. Our aim was to describe the atypical pattern of increased fatty
degeneration in the infraspinatus muscle compared with the supraspinatus
in patients with a massive
Aims. The treatment of septic arthritis of the shoulder is challenging.
The infection frequently recurs and the clinical outcome can be
very poor. We aimed to review the outcomes following the use of
continuous negative pressure after open debridement with a large
diameter drain in patients with septic arthritis of the shoulder. Patients and Methods. A total of 68 consecutive patients with septic arthritis of the
shoulder underwent arthrotomy, irrigation and debridement. A small
diameter suction drain was placed in the glenohumeral joint and
a large diameter drain was placed in the subacromial space with
continuous negative pressure of 15 cm H. 2. O. All patients
received a standardised protocol of antibiotics for a mean of 5.1
weeks (two to 11.1). Results. Negative pressure was maintained for a mean of 24 days (14 to
32). A total of 67 patients (98.5%) were cured without further treatment
being required. At a mean follow-up of 14 months (three to 72),
the mean forward flexion was 123° (80° to 140°) and the mean external
rotation was 28°(10° to 40°) in those with a
The August 2012 Shoulder &
Elbow Roundup. 360. looks at: platelet-rich fibrin matrix and the torn
The purpose of this study was to evaluate the
natural history of rheumatoid disease of the shoulder over an eight-year
period. Our hypothesis was that progression of the disease is associated
with a decrease in function with time. A total of 22 patients (44 shoulders; 17 women, 5 men, (mean
age 63)) with rheumatoid arthritis were followed for eight years.
All shoulders were assessed using the Constant score, anteroposterior
radiographs (Larsen score, Upward-Migration-Index (UMI)) and ultrasound
(US). At final follow-up, the Short Form-36, disabilities of the
arm, shoulder and hand (DASH) Score, erythrocyte sedimentation rate
and use of anti-rheumatic medication were determined. The mean Constant score was 72 points (50 to 88) at baseline
and 69 points (25 to 100) at final follow-up. Radiological evaluation
showed progressive destruction of the peri-articular structures
with time. This progression of joint and